Vulnerabilites related to Autodesk - Vault Basic Client
cve-2024-8896
Vulnerability from cvelistv5
Published
2024-10-29 21:43
Modified
2025-02-03 18:08
Summary
A maliciously crafted DXF file when parsed in acdb25.dll through Autodesk AutoCAD can force to access a variable prior to initialization. A malicious actor can leverage this vulnerability to cause a crash, write sensitive data, or execute arbitrary code in the context of the current process.
Impacted products
Vendor Product Version
Autodesk AutoCAD Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD LT Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD Architecture Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD Electrical Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD Mechanical Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD MEP Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD Plant 3D Version: 2025   < 2025.1.1
Create a notification for this product.
   AutoCAD Civil 3D Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Advance Steel Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk DWG TrueView Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Infrastructure Parts Editor Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Inventor Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Navisworks Manage Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Navisworks Simulate Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Revit Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Vault Basic Client Version: 2025   < 2025.1.1
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-8896",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-30T13:51:33.412413Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-30T15:01:25.860Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_lt:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD LT",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_architecture:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD Architecture",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_electrical:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD Electrical",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_mechanical:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD Mechanical",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_mep:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD MEP",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_plant_3d:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD Plant 3D",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_civil_3d:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Civil 3D",
          "vendor": "AutoCAD",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_advance_steel:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Advance Steel",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:dwg_trueview:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "DWG TrueView",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:infrastructure_parts_editor:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Infrastructure Parts Editor",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:inventor:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Inventor",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:navisworks_manage:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Navisworks Manage",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:navisworks_simulate:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Navisworks Simulate",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:revit:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Revit",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:vault_basic_client:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Vault Basic Client",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A maliciously crafted DXF file when parsed in acdb25.dll\u0026nbsp;through Autodesk AutoCAD can force to access a variable prior to initialization. A malicious actor can leverage this vulnerability to cause a crash, write sensitive data, or execute arbitrary code in the context of the current process."
            }
          ],
          "value": "A maliciously crafted DXF file when parsed in acdb25.dll\u00a0through Autodesk AutoCAD can force to access a variable prior to initialization. A malicious actor can leverage this vulnerability to cause a crash, write sensitive data, or execute arbitrary code in the context of the current process."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-100",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-100 Overflow Buffers"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-908",
              "description": "CWE-908 Use of Uninitialized Resource",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-03T18:08:56.904Z",
        "orgId": "7e40ea87-bc65-4944-9723-dd79dd760601",
        "shortName": "autodesk"
      },
      "references": [
        {
          "url": "https://www.autodesk.com/trust/security-advisories/adsk-sa-2024-0021"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Autodesk AutoCAD DXF File Parsing Unitialized Variable Code Execution Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7e40ea87-bc65-4944-9723-dd79dd760601",
    "assignerShortName": "autodesk",
    "cveId": "CVE-2024-8896",
    "datePublished": "2024-10-29T21:43:11.437Z",
    "dateReserved": "2024-09-16T14:34:49.668Z",
    "dateUpdated": "2025-02-03T18:08:56.904Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-7991
Vulnerability from cvelistv5
Published
2024-10-29 21:49
Modified
2025-02-10 20:42
Summary
A maliciously crafted DWG file, when parsed through Autodesk AutoCAD and certain AutoCAD-based products, may force an Out-of-Bounds Write vulnerability. A malicious actor may leverage this vulnerability to cause a crash, cause data corruption, or execute arbitrary code in the context of the current process.
Impacted products
Vendor Product Version
Autodesk AutoCAD Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD LT Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD Architecture Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD Electrical Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD Mechanical Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD MEP Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD Plant 3D Version: 2025   < 2025.1.1
Create a notification for this product.
   AutoCAD Civil 3D Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Advance Steel Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk DWG TrueView Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Infrastructure Parts Editor Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Inventor Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Navisworks Manage Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Navisworks Simulate Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Revit Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Vault Basic Client Version: 2025   < 2025.1.1
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-7991",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-30T13:51:28.629296Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-30T15:00:49.205Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_lt:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD LT",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_architecture:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD Architecture",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_electrical:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD Electrical",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_mechanical:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD Mechanical",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_mep:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD MEP",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_plant_3d:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD Plant 3D",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_civil_3d:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Civil 3D",
          "vendor": "AutoCAD",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_advance_steel:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Advance Steel",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:dwg_trueview:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "DWG TrueView",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:infrastructure_parts_editor:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Infrastructure Parts Editor",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:inventor:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Inventor",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:navisworks_manage:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Navisworks Manage",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:navisworks_simulate:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Navisworks Simulate",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:revit:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Revit",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:vault_basic_client:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Vault Basic Client",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA maliciously crafted DWG file, when parsed through Autodesk AutoCAD and certain AutoCAD-based products, may force an Out-of-Bounds Write vulnerability. A malicious actor may leverage this vulnerability to cause a crash, cause data corruption, or execute arbitrary code in the context of the current process.\u003c/span\u003e\u003cbr\u003e"
            }
          ],
          "value": "A maliciously crafted DWG file, when parsed through Autodesk AutoCAD and certain AutoCAD-based products, may force an Out-of-Bounds Write vulnerability. A malicious actor may leverage this vulnerability to cause a crash, cause data corruption, or execute arbitrary code in the context of the current process."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-100",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-100 Overflow Buffers"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787 Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-10T20:42:38.601Z",
        "orgId": "7e40ea87-bc65-4944-9723-dd79dd760601",
        "shortName": "autodesk"
      },
      "references": [
        {
          "url": "https://autodesk.com/trust/security-advisories/adsk-sa-2024-0021"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Autodesk AutoCAD DWG Out-of-Bounds Write Code Execution Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7e40ea87-bc65-4944-9723-dd79dd760601",
    "assignerShortName": "autodesk",
    "cveId": "CVE-2024-7991",
    "datePublished": "2024-10-29T21:49:02.128Z",
    "dateReserved": "2024-08-19T21:37:04.701Z",
    "dateUpdated": "2025-02-10T20:42:38.601Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-9996
Vulnerability from cvelistv5
Published
2024-10-29 21:45
Modified
2025-02-10 20:41
Summary
A maliciously crafted DWG file, when parsed in acdb25.dll through Autodesk AutoCAD, may force an Out-of-Bounds Write vulnerability. A malicious actor may leverage this vulnerability to cause a crash, cause data corruption, or execute arbitrary code in the context of the current process.
Impacted products
Vendor Product Version
Autodesk AutoCAD Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD LT Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD Architecture Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD Electrical Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD Mechanical Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD MEP Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD Plant 3D Version: 2025   < 2025.1.1
Create a notification for this product.
   AutoCAD Civil 3D Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Advance Steel Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk DWG TrueView Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Infrastructure Parts Editor Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Inventor Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Navisworks Manage Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Navisworks Simulate Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Revit Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Vault Basic Client Version: 2025   < 2025.1.1
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-9996",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-30T13:51:30.961199Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-30T15:01:08.447Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_lt:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD LT",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_architecture:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD Architecture",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_electrical:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD Electrical",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_mechanical:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD Mechanical",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_mep:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD MEP",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_plant_3d:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD Plant 3D",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_civil_3d:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Civil 3D",
          "vendor": "AutoCAD",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_advance_steel:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Advance Steel",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:dwg_trueview:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "DWG TrueView",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:infrastructure_parts_editor:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Infrastructure Parts Editor",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:inventor:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Inventor",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:navisworks_manage:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Navisworks Manage",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:navisworks_simulate:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Navisworks Simulate",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:revit:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Revit",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:vault_basic_client:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Vault Basic Client",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA maliciously crafted DWG file, when parsed in acdb25.dll through Autodesk AutoCAD, may force an Out-of-Bounds Write vulnerability. A malicious actor may leverage this vulnerability to cause a crash, cause data corruption, or execute arbitrary code in the context of the current process.\u003c/span\u003e\u003cbr\u003e"
            }
          ],
          "value": "A maliciously crafted DWG file, when parsed in acdb25.dll through Autodesk AutoCAD, may force an Out-of-Bounds Write vulnerability. A malicious actor may leverage this vulnerability to cause a crash, cause data corruption, or execute arbitrary code in the context of the current process."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-100",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-100 Overflow Buffers"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787 Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-10T20:41:08.698Z",
        "orgId": "7e40ea87-bc65-4944-9723-dd79dd760601",
        "shortName": "autodesk"
      },
      "references": [
        {
          "url": "https://www.autodesk.com/trust/security-advisories/adsk-sa-2024-0021"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Autodesk AutoCAD DWG File Parsing Out-Of-Bounds Write Code Execution Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7e40ea87-bc65-4944-9723-dd79dd760601",
    "assignerShortName": "autodesk",
    "cveId": "CVE-2024-9996",
    "datePublished": "2024-10-29T21:45:17.527Z",
    "dateReserved": "2024-10-15T13:39:36.931Z",
    "dateUpdated": "2025-02-10T20:41:08.698Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-7992
Vulnerability from cvelistv5
Published
2024-10-29 21:50
Modified
2025-02-03 18:06
Summary
A maliciously crafted DWG file, when parsed through Autodesk AutoCAD and certain AutoCAD-based products, can force a Stack-based Buffer Overflow. A malicious actor can leverage this vulnerability to cause a crash, read sensitive data, or execute arbitrary code in the context of the current process.
Impacted products
Vendor Product Version
Autodesk AutoCAD Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD LT Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD Architecture Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD Electrical Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD Mechanical Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD MEP Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD Plant 3D Version: 2025   < 2025.1.1
Create a notification for this product.
   AutoCAD Civil 3D Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Advance Steel Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk DWG TrueView Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Infrastructure Parts Editor Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Inventor Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Navisworks Manage Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Navisworks Simulate Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Revit Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Vault Basic Client Version: 2025   < 2025.1.1
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-7992",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-30T13:51:27.431632Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-30T15:00:32.444Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_lt:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD LT",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_architecture:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD Architecture",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_electrical:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD Electrical",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_mechanical:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD Mechanical",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_mep:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD MEP",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_plant_3d:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD Plant 3D",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_civil_3d:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Civil 3D",
          "vendor": "AutoCAD",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_advance_steel:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Advance Steel",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:dwg_trueview:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "DWG TrueView",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:infrastructure_parts_editor:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Infrastructure Parts Editor",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:inventor:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Inventor",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:navisworks_manage:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Navisworks Manage",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:navisworks_simulate:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Navisworks Simulate",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:revit:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Revit",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:vault_basic_client:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Vault Basic Client",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA maliciously crafted DWG file, when parsed\u003c/span\u003e \u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ethrough Autodesk AutoCAD and certain AutoCAD-based products, can force a Stack-based Buffer Overflow. A malicious actor can leverage this vulnerability to cause a crash, read sensitive data, or execute arbitrary code in the context of the current process.\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e\u003cbr\u003e"
            }
          ],
          "value": "A maliciously crafted DWG file, when parsed through Autodesk AutoCAD and certain AutoCAD-based products, can force a Stack-based Buffer Overflow. A malicious actor can leverage this vulnerability to cause a crash, read sensitive data, or execute arbitrary code in the context of the current process."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-100",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-100 Overflow Buffers"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-03T18:06:30.783Z",
        "orgId": "7e40ea87-bc65-4944-9723-dd79dd760601",
        "shortName": "autodesk"
      },
      "references": [
        {
          "url": "https://autodesk.com/trust/security-advisories/adsk-sa-2024-0021"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Autodesk AutoCAD DWG Stack-Based Buffer Overflow Code Execution Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7e40ea87-bc65-4944-9723-dd79dd760601",
    "assignerShortName": "autodesk",
    "cveId": "CVE-2024-7992",
    "datePublished": "2024-10-29T21:50:13.232Z",
    "dateReserved": "2024-08-19T21:37:08.684Z",
    "dateUpdated": "2025-02-03T18:06:30.783Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-9997
Vulnerability from cvelistv5
Published
2024-10-29 21:45
Modified
2025-02-03 18:07
Summary
A maliciously crafted DWG file when parsed in acdb25.dll through Autodesk AutoCAD can force a Memory Corruption vulnerability. A malicious actor can leverage this vulnerability to cause a crash, write sensitive data, or execute arbitrary code in the context of the current process.
Impacted products
Vendor Product Version
Autodesk AutoCAD Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD LT Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD Architecture Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD Electrical Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD Mechanical Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD MEP Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD Plant 3D Version: 2025   < 2025.1.1
Create a notification for this product.
   AutoCAD Civil 3D Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Advance Steel Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk DWG TrueView Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Infrastructure Parts Editor Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Inventor Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Navisworks Manage Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Navisworks Simulate Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Revit Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Vault Basic Client Version: 2025   < 2025.1.1
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-9997",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-30T13:51:29.745174Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-30T15:00:57.856Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_lt:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD LT",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_architecture:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD Architecture",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_electrical:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD Electrical",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_mechanical:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD Mechanical",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_mep:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD MEP",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_plant_3d:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD Plant 3D",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_civil_3d:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Civil 3D",
          "vendor": "AutoCAD",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_advance_steel:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Advance Steel",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:dwg_trueview:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "DWG TrueView",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:infrastructure_parts_editor:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Infrastructure Parts Editor",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:inventor:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Inventor",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:navisworks_manage:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Navisworks Manage",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:navisworks_simulate:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Navisworks Simulate",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:revit:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Revit",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:vault_basic_client:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Vault Basic Client",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A maliciously crafted DWG file when parsed in acdb25.dll through Autodesk AutoCAD can force a Memory Corruption vulnerability.  A malicious actor can leverage this vulnerability to cause a crash, write sensitive data, or execute arbitrary code in the context of the current process.\u003cbr\u003e"
            }
          ],
          "value": "A maliciously crafted DWG file when parsed in acdb25.dll through Autodesk AutoCAD can force a Memory Corruption vulnerability.  A malicious actor can leverage this vulnerability to cause a crash, write sensitive data, or execute arbitrary code in the context of the current process."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-100",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-100 Overflow Buffers"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-03T18:07:41.813Z",
        "orgId": "7e40ea87-bc65-4944-9723-dd79dd760601",
        "shortName": "autodesk"
      },
      "references": [
        {
          "url": "https://www.autodesk.com/trust/security-advisories/adsk-sa-2024-0021"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Autodesk AutoCAD DWG File Parsing Memory Corruption Code Execution Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7e40ea87-bc65-4944-9723-dd79dd760601",
    "assignerShortName": "autodesk",
    "cveId": "CVE-2024-9997",
    "datePublished": "2024-10-29T21:45:59.005Z",
    "dateReserved": "2024-10-15T13:39:39.800Z",
    "dateUpdated": "2025-02-03T18:07:41.813Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-9489
Vulnerability from cvelistv5
Published
2024-10-29 21:44
Modified
2025-02-03 18:04
Summary
A maliciously crafted DWG file when parsed in ACAD.exe through Autodesk AutoCAD can force a Memory Corruption vulnerability. A malicious actor can leverage this vulnerability to cause a crash, write sensitive data, or execute arbitrary code in the context of the current process.
Impacted products
Vendor Product Version
Autodesk AutoCAD Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD LT Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD Architecture Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD Electrical Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD Mechanical Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD MEP Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk AutoCAD Plant 3D Version: 2025   < 2025.1.1
Create a notification for this product.
   AutoCAD Civil 3D Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Advance Steel Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk DWG TrueView Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Infrastructure Parts Editor Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Inventor Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Navisworks Manage Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Navisworks Simulate Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Revit Version: 2025   < 2025.1.1
Create a notification for this product.
   Autodesk Vault Basic Client Version: 2025   < 2025.1.1
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-9489",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-30T13:51:32.196438Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-30T15:01:17.148Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_lt:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD LT",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_architecture:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD Architecture",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_electrical:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD Electrical",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_mechanical:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD Mechanical",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_mep:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD MEP",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_plant_3d:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "AutoCAD Plant 3D",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_civil_3d:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Civil 3D",
          "vendor": "AutoCAD",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:autocad_advance_steel:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Advance Steel",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:dwg_trueview:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "DWG TrueView",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:infrastructure_parts_editor:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Infrastructure Parts Editor",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:inventor:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Inventor",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:navisworks_manage:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Navisworks Manage",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:navisworks_simulate:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Navisworks Simulate",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:revit:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Revit",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpe": [
            "cpe:2.3:a:autodesk:vault_basic_client:2025:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Vault Basic Client",
          "vendor": "Autodesk",
          "versions": [
            {
              "lessThan": "2025.1.1",
              "status": "affected",
              "version": "2025",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A maliciously crafted DWG file when parsed in ACAD.exe through Autodesk AutoCAD can force a Memory Corruption vulnerability. A malicious actor can leverage this vulnerability to cause a crash, write sensitive data, or execute arbitrary code in the context of the current process."
            }
          ],
          "value": "A maliciously crafted DWG file when parsed in ACAD.exe through Autodesk AutoCAD can force a Memory Corruption vulnerability. A malicious actor can leverage this vulnerability to cause a crash, write sensitive data, or execute arbitrary code in the context of the current process."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-100",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-100 Overflow Buffers"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-03T18:04:44.972Z",
        "orgId": "7e40ea87-bc65-4944-9723-dd79dd760601",
        "shortName": "autodesk"
      },
      "references": [
        {
          "url": "https://www.autodesk.com/trust/security-advisories/adsk-sa-2024-0021"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Autodesk AutoCAD DWG File Parsing Memory Corruption Code Execution Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7e40ea87-bc65-4944-9723-dd79dd760601",
    "assignerShortName": "autodesk",
    "cveId": "CVE-2024-9489",
    "datePublished": "2024-10-29T21:44:39.027Z",
    "dateReserved": "2024-10-03T18:19:18.769Z",
    "dateUpdated": "2025-02-03T18:04:44.972Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}