Refine your search

5 vulnerabilities found for Terra AC wallbox by ABB

jvndb-2025-000094
Vulnerability from jvndb
Published
2025-12-05 14:12
Modified
2025-12-05 14:12
Severity ?
Summary
Multiple vulnerabilities in ABB Terra AC Wallbox
Details
Terra AC Wallbox provided by ABB contains the following vulnerability. * Heap-based buffer overflow (CWE-122) - CVE-2025-10504 * Classic buffer overflow (CWE-120) - CVE-2025-12142 * Stack-based buffer overflow (CWE-121) - CVE-2025-12143 Ryo Kato of Panasonic reported this vulnerability to IPA. JPCERT/CC coordinated with the developer under Information Security Early Warning Partnership.
Impacted products
Show details on JVN DB website


{
  "@rdf:about": "https://jvndb.jvn.jp/en/contents/2025/JVNDB-2025-000094.html",
  "dc:date": "2025-12-05T14:12+09:00",
  "dcterms:issued": "2025-12-05T14:12+09:00",
  "dcterms:modified": "2025-12-05T14:12+09:00",
  "description": "Terra AC Wallbox provided by ABB contains the following vulnerability.\r\n\r\n* Heap-based buffer overflow (CWE-122) - CVE-2025-10504\r\n* Classic buffer overflow (CWE-120) - CVE-2025-12142 \r\n* Stack-based buffer overflow (CWE-121) - CVE-2025-12143\r\n\r\nRyo Kato of Panasonic reported this vulnerability to IPA.\r\nJPCERT/CC coordinated with the developer under Information Security Early Warning Partnership.",
  "link": "https://jvndb.jvn.jp/en/contents/2025/JVNDB-2025-000094.html",
  "sec:cpe": {
    "#text": "cpe:/o:abb:terra_ac_wallbox",
    "@product": "Terra AC wallbox",
    "@vendor": "ABB",
    "@version": "2.2"
  },
  "sec:cvss": {
    "@score": "6.1",
    "@severity": "Medium",
    "@type": "Base",
    "@vector": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
    "@version": "3.0"
  },
  "sec:identifier": "JVNDB-2025-000094",
  "sec:references": [
    {
      "#text": "https://jvn.jp/en/jp/JVN84024274/index.html",
      "@id": "JVN#84024274",
      "@source": "JVN"
    },
    {
      "#text": "https://www.cve.org/CVERecord?id=CVE-2025-10504",
      "@id": "CVE-2025-10504",
      "@source": "CVE"
    },
    {
      "#text": "https://www.cve.org/CVERecord?id=CVE-2025-12142",
      "@id": "CVE-2025-12142",
      "@source": "CVE"
    },
    {
      "#text": "https://www.cve.org/CVERecord?id=CVE-2025-12143",
      "@id": "CVE-2025-12143",
      "@source": "CVE"
    },
    {
      "#text": "https://www.ipa.go.jp/en/security/vulnerabilities/cwe.html",
      "@id": "CWE-Other",
      "@title": "No Mapping(CWE-Other)"
    }
  ],
  "title": "Multiple vulnerabilities in ABB Terra AC Wallbox"
}

CVE-2025-12143 (GCVE-0-2025-12143)
Vulnerability from nvd
Published
2025-11-28 11:59
Modified
2025-11-28 14:16
CWE
  • CWE-121 - Stack-based Buffer Overflow
Summary
Stack-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33.
Impacted products
Vendor Product Version
ABB Terra AC wallbox Version: 0   <
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-12143",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-28T14:16:36.401623Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-28T14:16:43.237Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Terra AC wallbox",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "1.8.33",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Stack-based Buffer Overflow vulnerability in ABB Terra AC wallbox.\u003cp\u003eThis issue affects Terra AC wallbox: through 1.8.33.\u003c/p\u003e"
            }
          ],
          "value": "Stack-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NO",
            "Recovery": "AUTOMATIC",
            "Safety": "NEGLIGIBLE",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "ADJACENT",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "DIFFUSE",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/S:N/AU:N/R:A/V:D/RE:L",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "LOW"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-28T11:59:27.485Z",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108471A8107\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Stack Memory Corruption Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2025-12143",
    "datePublished": "2025-11-28T11:59:27.485Z",
    "dateReserved": "2025-10-24T10:40:24.131Z",
    "dateUpdated": "2025-11-28T14:16:43.237Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-12142 (GCVE-0-2025-12142)
Vulnerability from nvd
Published
2025-10-29 12:00
Modified
2025-10-29 13:30
CWE
  • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Summary
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33.
Impacted products
Vendor Product Version
ABB Terra AC wallbox Version: 0   <
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-12142",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-29T13:25:28.068483Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-29T13:30:33.090Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Terra AC wallbox",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "1.8.33",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:abb:terra_ac_wallbox:*:*:*:*:*:*:*:*",
                  "versionEndIncluding": "1.8.33",
                  "versionStartIncluding": "0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "datePublic": "2025-10-27T04:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability in ABB Terra AC wallbox.\u003cp\u003eThis issue affects Terra AC wallbox: through 1.8.33.\u003c/p\u003e"
            }
          ],
          "value": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NO",
            "Recovery": "AUTOMATIC",
            "Safety": "NEGLIGIBLE",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "ADJACENT",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "DIFFUSE",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/S:N/AU:N/R:A/V:D/RE:L",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "LOW"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-29T12:00:42.236Z",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108471A8107\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "BSS(Block Started by Symbol) Memory Corruption Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.4.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2025-12142",
    "datePublished": "2025-10-29T12:00:42.236Z",
    "dateReserved": "2025-10-24T10:40:22.394Z",
    "dateUpdated": "2025-10-29T13:30:33.090Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-12143 (GCVE-0-2025-12143)
Vulnerability from cvelistv5
Published
2025-11-28 11:59
Modified
2025-11-28 14:16
CWE
  • CWE-121 - Stack-based Buffer Overflow
Summary
Stack-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33.
Impacted products
Vendor Product Version
ABB Terra AC wallbox Version: 0   <
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-12143",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-28T14:16:36.401623Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-28T14:16:43.237Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Terra AC wallbox",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "1.8.33",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Stack-based Buffer Overflow vulnerability in ABB Terra AC wallbox.\u003cp\u003eThis issue affects Terra AC wallbox: through 1.8.33.\u003c/p\u003e"
            }
          ],
          "value": "Stack-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NO",
            "Recovery": "AUTOMATIC",
            "Safety": "NEGLIGIBLE",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "ADJACENT",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "DIFFUSE",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/S:N/AU:N/R:A/V:D/RE:L",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "LOW"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-28T11:59:27.485Z",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108471A8107\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Stack Memory Corruption Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2025-12143",
    "datePublished": "2025-11-28T11:59:27.485Z",
    "dateReserved": "2025-10-24T10:40:24.131Z",
    "dateUpdated": "2025-11-28T14:16:43.237Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-12142 (GCVE-0-2025-12142)
Vulnerability from cvelistv5
Published
2025-10-29 12:00
Modified
2025-10-29 13:30
CWE
  • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Summary
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33.
Impacted products
Vendor Product Version
ABB Terra AC wallbox Version: 0   <
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-12142",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-29T13:25:28.068483Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-29T13:30:33.090Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Terra AC wallbox",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "1.8.33",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:abb:terra_ac_wallbox:*:*:*:*:*:*:*:*",
                  "versionEndIncluding": "1.8.33",
                  "versionStartIncluding": "0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "datePublic": "2025-10-27T04:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability in ABB Terra AC wallbox.\u003cp\u003eThis issue affects Terra AC wallbox: through 1.8.33.\u003c/p\u003e"
            }
          ],
          "value": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NO",
            "Recovery": "AUTOMATIC",
            "Safety": "NEGLIGIBLE",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "ADJACENT",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "DIFFUSE",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/S:N/AU:N/R:A/V:D/RE:L",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "LOW"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-29T12:00:42.236Z",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108471A8107\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "BSS(Block Started by Symbol) Memory Corruption Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.4.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2025-12142",
    "datePublished": "2025-10-29T12:00:42.236Z",
    "dateReserved": "2025-10-24T10:40:22.394Z",
    "dateUpdated": "2025-10-29T13:30:33.090Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}