Vulnerabilites related to Eaton - Intelligent Power Manager Infrastructure (IPM Infrastructure)
cve-2021-23284
Vulnerability from cvelistv5
Published
2022-04-18 16:20
Modified
2024-09-17 01:31
Severity ?
EPSS score ?
Summary
Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) version 1.5.0plus205 and all prior versions are vulnerable to Stored Cross-site Scripting vulnerability. This issue affects: Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) all version 1.5.0plus205 and prior versions.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Eaton | Intelligent Power Manager Infrastructure (IPM Infrastructure) |
Version: all < |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T19:05:55.677Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/Eaton-Intelligent-Power-Manager-%28IPM%29-Infrastructure-Vulnerability-Advisory_1001c_V1.0.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.eaton.com/content/dam/eaton/products/backup-power-ups-surge-it-power-distribution/power-management-software-connectivity/eaton-intelligent-power-manager/software/ipm-understand-edition-emea/eaton-ipminfra-eolmemo-en-us.pdf." } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Intelligent Power Manager Infrastructure (IPM Infrastructure)", "vendor": "Eaton", "versions": [ { "lessThanOrEqual": "1.5.0plus205", "status": "affected", "version": "all", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "Eaton thanks the ICS-Cert organization and individuals for their coordinated support on the security vulnerability: CVE-2021-23284 \u2013 Micheal Heinzl via ICS-Cert" } ], "datePublic": "2022-04-01T00:00:00", "descriptions": [ { "lang": "en", "value": "Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) version 1.5.0plus205 and all prior versions are vulnerable to Stored Cross-site Scripting vulnerability. This issue affects: Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) all version 1.5.0plus205 and prior versions." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 5.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-79", "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-04-18T16:20:32", "orgId": "63703b7d-23e2-41ef-94b3-a3c6333f7759", "shortName": "Eaton" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/Eaton-Intelligent-Power-Manager-%28IPM%29-Infrastructure-Vulnerability-Advisory_1001c_V1.0.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.eaton.com/content/dam/eaton/products/backup-power-ups-surge-it-power-distribution/power-management-software-connectivity/eaton-intelligent-power-manager/software/ipm-understand-edition-emea/eaton-ipminfra-eolmemo-en-us.pdf." } ], "solutions": [ { "lang": "en", "value": "The product has reached its End Of Life, the notification has been posted at: Lifecycle Notification. Check References section. \nThe transition to IPM Monitor Edition is in progress. Refer the Product page for further details." } ], "source": { "discovery": "EXTERNAL" }, "title": "Security issues in Eaton Intelligent Power Manager Infrastructure", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "CybersecurityCOE@eaton.com", "DATE_PUBLIC": "2022-04-01T10:56:00.000Z", "ID": "CVE-2021-23284", "STATE": "PUBLIC", "TITLE": "Security issues in Eaton Intelligent Power Manager Infrastructure" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Intelligent Power Manager Infrastructure (IPM Infrastructure)", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "all", "version_value": "1.5.0plus205" } ] } } ] }, "vendor_name": "Eaton" } ] } }, "credit": [ { "lang": "eng", "value": "Eaton thanks the ICS-Cert organization and individuals for their coordinated support on the security vulnerability: CVE-2021-23284 \u2013 Micheal Heinzl via ICS-Cert" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) version 1.5.0plus205 and all prior versions are vulnerable to Stored Cross-site Scripting vulnerability. This issue affects: Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) all version 1.5.0plus205 and prior versions." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 5.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/Eaton-Intelligent-Power-Manager-(IPM)-Infrastructure-Vulnerability-Advisory_1001c_V1.0.pdf", "refsource": "MISC", "url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/Eaton-Intelligent-Power-Manager-(IPM)-Infrastructure-Vulnerability-Advisory_1001c_V1.0.pdf" }, { "name": "https://www.eaton.com/content/dam/eaton/products/backup-power-ups-surge-it-power-distribution/power-management-software-connectivity/eaton-intelligent-power-manager/software/ipm-understand-edition-emea/eaton-ipminfra-eolmemo-en-us.pdf.", "refsource": "MISC", "url": "https://www.eaton.com/content/dam/eaton/products/backup-power-ups-surge-it-power-distribution/power-management-software-connectivity/eaton-intelligent-power-manager/software/ipm-understand-edition-emea/eaton-ipminfra-eolmemo-en-us.pdf." } ] }, "solution": [ { "lang": "en", "value": "The product has reached its End Of Life, the notification has been posted at: Lifecycle Notification. Check References section. \nThe transition to IPM Monitor Edition is in progress. Refer the Product page for further details." } ], "source": { "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "63703b7d-23e2-41ef-94b3-a3c6333f7759", "assignerShortName": "Eaton", "cveId": "CVE-2021-23284", "datePublished": "2022-04-18T16:20:32.573926Z", "dateReserved": "2021-01-08T00:00:00", "dateUpdated": "2024-09-17T01:31:40.742Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-23286
Vulnerability from cvelistv5
Published
2022-04-18 16:20
Modified
2024-09-17 00:41
Severity ?
EPSS score ?
Summary
Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) version 1.5.0plus205 and all prior versions are vulnerable to CSV Formula Injection. This issue affects: Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) all version 1.5.0plus205 and prior versions.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Eaton | Intelligent Power Manager Infrastructure (IPM Infrastructure) |
Version: all < |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T19:05:55.593Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/Eaton-Intelligent-Power-Manager-%28IPM%29-Infrastructure-Vulnerability-Advisory_1001c_V1.0.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.eaton.com/content/dam/eaton/products/backup-power-ups-surge-it-power-distribution/power-management-software-connectivity/eaton-intelligent-power-manager/software/ipm-understand-edition-emea/eaton-ipminfra-eolmemo-en-us.pdf." } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Intelligent Power Manager Infrastructure (IPM Infrastructure)", "vendor": "Eaton", "versions": [ { "lessThanOrEqual": "1.5.0plus205", "status": "affected", "version": "all", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "Eaton thanks the ICS-Cert organization and individuals for their coordinated support on the security vulnerability: CVE-2021-23286 \u2013 Micheal Heinzl via ICS-Cert" } ], "datePublic": "2022-04-01T00:00:00", "descriptions": [ { "lang": "en", "value": "Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) version 1.5.0plus205 and all prior versions are vulnerable to CSV Formula Injection. This issue affects: Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) all version 1.5.0plus205 and prior versions." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 5.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-1236", "description": "CWE-1236: Improper Neutralization of Formula Elements in a CSV File", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-04-18T16:20:33", "orgId": "63703b7d-23e2-41ef-94b3-a3c6333f7759", "shortName": "Eaton" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/Eaton-Intelligent-Power-Manager-%28IPM%29-Infrastructure-Vulnerability-Advisory_1001c_V1.0.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.eaton.com/content/dam/eaton/products/backup-power-ups-surge-it-power-distribution/power-management-software-connectivity/eaton-intelligent-power-manager/software/ipm-understand-edition-emea/eaton-ipminfra-eolmemo-en-us.pdf." } ], "solutions": [ { "lang": "en", "value": "The product has reached its End Of Life, the notification has been posted at: Lifecycle Notification: \nThe transition to IPM Monitor Edition is in progress. Refer the Product page for further details." } ], "source": { "discovery": "EXTERNAL" }, "title": "Security issues in Eaton Intelligent Power Manager Infrastructure", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "CybersecurityCOE@eaton.com", "DATE_PUBLIC": "2022-04-01T10:56:00.000Z", "ID": "CVE-2021-23286", "STATE": "PUBLIC", "TITLE": "Security issues in Eaton Intelligent Power Manager Infrastructure" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Intelligent Power Manager Infrastructure (IPM Infrastructure)", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "all", "version_value": "1.5.0plus205" } ] } } ] }, "vendor_name": "Eaton" } ] } }, "credit": [ { "lang": "eng", "value": "Eaton thanks the ICS-Cert organization and individuals for their coordinated support on the security vulnerability: CVE-2021-23286 \u2013 Micheal Heinzl via ICS-Cert" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) version 1.5.0plus205 and all prior versions are vulnerable to CSV Formula Injection. This issue affects: Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) all version 1.5.0plus205 and prior versions." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 5.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-1236: Improper Neutralization of Formula Elements in a CSV File" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/Eaton-Intelligent-Power-Manager-(IPM)-Infrastructure-Vulnerability-Advisory_1001c_V1.0.pdf", "refsource": "MISC", "url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/Eaton-Intelligent-Power-Manager-(IPM)-Infrastructure-Vulnerability-Advisory_1001c_V1.0.pdf" }, { "name": "https://www.eaton.com/content/dam/eaton/products/backup-power-ups-surge-it-power-distribution/power-management-software-connectivity/eaton-intelligent-power-manager/software/ipm-understand-edition-emea/eaton-ipminfra-eolmemo-en-us.pdf.", "refsource": "MISC", "url": "https://www.eaton.com/content/dam/eaton/products/backup-power-ups-surge-it-power-distribution/power-management-software-connectivity/eaton-intelligent-power-manager/software/ipm-understand-edition-emea/eaton-ipminfra-eolmemo-en-us.pdf." } ] }, "solution": [ { "lang": "en", "value": "The product has reached its End Of Life, the notification has been posted at: Lifecycle Notification: \nThe transition to IPM Monitor Edition is in progress. Refer the Product page for further details." } ], "source": { "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "63703b7d-23e2-41ef-94b3-a3c6333f7759", "assignerShortName": "Eaton", "cveId": "CVE-2021-23286", "datePublished": "2022-04-18T16:20:33.351388Z", "dateReserved": "2021-01-08T00:00:00", "dateUpdated": "2024-09-17T00:41:59.713Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-23285
Vulnerability from cvelistv5
Published
2022-04-18 16:20
Modified
2024-09-16 22:41
Severity ?
EPSS score ?
Summary
Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) version 1.5.0plus205 and all prior versions are vulnerable to reflected Cross-site Scripting vulnerability. This issue affects: Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) all version 1.5.0plus205 and prior versions.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Eaton | Intelligent Power Manager Infrastructure (IPM Infrastructure) |
Version: all < |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T19:05:55.463Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/Eaton-Intelligent-Power-Manager-%28IPM%29-Infrastructure-Vulnerability-Advisory_1001c_V1.0.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.eaton.com/content/dam/eaton/products/backup-power-ups-surge-it-power-distribution/power-management-software-connectivity/eaton-intelligent-power-manager/software/ipm-understand-edition-emea/eaton-ipminfra-eolmemo-en-us.pdf." } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Intelligent Power Manager Infrastructure (IPM Infrastructure)", "vendor": "Eaton", "versions": [ { "lessThanOrEqual": "1.5.0plus205", "status": "affected", "version": "all", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "Eaton thanks the ICS-Cert organization and individuals for their coordinated support on the security vulnerability: CVE-2021-23285 \u2013 Micheal Heinzl via ICS-Cert" } ], "datePublic": "2022-04-01T00:00:00", "descriptions": [ { "lang": "en", "value": "Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) version 1.5.0plus205 and all prior versions are vulnerable to reflected Cross-site Scripting vulnerability. This issue affects: Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) all version 1.5.0plus205 and prior versions." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 3.1, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-79", "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-04-18T16:20:31", "orgId": "63703b7d-23e2-41ef-94b3-a3c6333f7759", "shortName": "Eaton" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/Eaton-Intelligent-Power-Manager-%28IPM%29-Infrastructure-Vulnerability-Advisory_1001c_V1.0.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.eaton.com/content/dam/eaton/products/backup-power-ups-surge-it-power-distribution/power-management-software-connectivity/eaton-intelligent-power-manager/software/ipm-understand-edition-emea/eaton-ipminfra-eolmemo-en-us.pdf." } ], "solutions": [ { "lang": "en", "value": "The product has reached its End Of Life, the notification has been posted at: Lifecycle Notification: \nThe transition to IPM Monitor Edition is in progress. Refer the Product page for further details." } ], "source": { "discovery": "EXTERNAL" }, "title": "Security issues in Eaton Intelligent Power Manager Infrastructure", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "CybersecurityCOE@eaton.com", "DATE_PUBLIC": "2022-04-01T10:56:00.000Z", "ID": "CVE-2021-23285", "STATE": "PUBLIC", "TITLE": "Security issues in Eaton Intelligent Power Manager Infrastructure" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Intelligent Power Manager Infrastructure (IPM Infrastructure)", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "all", "version_value": "1.5.0plus205" } ] } } ] }, "vendor_name": "Eaton" } ] } }, "credit": [ { "lang": "eng", "value": "Eaton thanks the ICS-Cert organization and individuals for their coordinated support on the security vulnerability: CVE-2021-23285 \u2013 Micheal Heinzl via ICS-Cert" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) version 1.5.0plus205 and all prior versions are vulnerable to reflected Cross-site Scripting vulnerability. This issue affects: Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) all version 1.5.0plus205 and prior versions." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "HIGH", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 3.1, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/Eaton-Intelligent-Power-Manager-(IPM)-Infrastructure-Vulnerability-Advisory_1001c_V1.0.pdf", "refsource": "MISC", "url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/Eaton-Intelligent-Power-Manager-(IPM)-Infrastructure-Vulnerability-Advisory_1001c_V1.0.pdf" }, { "name": "https://www.eaton.com/content/dam/eaton/products/backup-power-ups-surge-it-power-distribution/power-management-software-connectivity/eaton-intelligent-power-manager/software/ipm-understand-edition-emea/eaton-ipminfra-eolmemo-en-us.pdf.", "refsource": "MISC", "url": "https://www.eaton.com/content/dam/eaton/products/backup-power-ups-surge-it-power-distribution/power-management-software-connectivity/eaton-intelligent-power-manager/software/ipm-understand-edition-emea/eaton-ipminfra-eolmemo-en-us.pdf." } ] }, "solution": [ { "lang": "en", "value": "The product has reached its End Of Life, the notification has been posted at: Lifecycle Notification: \nThe transition to IPM Monitor Edition is in progress. Refer the Product page for further details." } ], "source": { "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "63703b7d-23e2-41ef-94b3-a3c6333f7759", "assignerShortName": "Eaton", "cveId": "CVE-2021-23285", "datePublished": "2022-04-18T16:20:31.667003Z", "dateReserved": "2021-01-08T00:00:00", "dateUpdated": "2024-09-16T22:41:39.422Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }