Vulnerabilites related to Tenda - FH1201
cve-2024-42950
Vulnerability from cvelistv5
Published
2024-08-15 00:00
Modified
2024-08-21 16:42
Severity ?
EPSS score ?
Summary
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the Go parameter in the fromSafeClientFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
References
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:fh1201_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1201_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v1.2.0.14\\/408\\/" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-42950", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-08-16T18:05:21.659737Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400 Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-08-21T16:42:45.692Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the Go parameter in the fromSafeClientFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-08-15T16:20:47.493191", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1201/fromSafeClientFilter_Go.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-42950", "datePublished": "2024-08-15T00:00:00", "dateReserved": "2024-08-05T00:00:00", "dateUpdated": "2024-08-21T16:42:45.692Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-42952
Vulnerability from cvelistv5
Published
2024-08-15 00:00
Modified
2024-08-16 13:51
Severity ?
EPSS score ?
Summary
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromqossetting function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
References
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:fh1201_firmware:1.2.0.14:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1201_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.2.0.14" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-42952", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-08-16T13:50:32.482240Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-16T13:51:31.803Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromqossetting function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-08-15T16:20:46.468322", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1201/fromqossetting_page.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-42952", "datePublished": "2024-08-15T00:00:00", "dateReserved": "2024-08-05T00:00:00", "dateUpdated": "2024-08-16T13:51:31.803Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-42943
Vulnerability from cvelistv5
Published
2024-08-15 00:00
Modified
2024-08-16 18:10
Severity ?
EPSS score ?
Summary
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the PPPOEPassword parameter in the fromAdvSetWan function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
References
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:fh1201_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1201_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v1.2.0.14\\/408\\/" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-42943", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-08-16T18:08:49.148339Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400 Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-08-16T18:10:20.544Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the PPPOEPassword parameter in the fromAdvSetWan function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-08-15T16:20:57.380877", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1201/fromAdvSetWan_PPPOEPassword.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-42943", "datePublished": "2024-08-15T00:00:00", "dateReserved": "2024-08-05T00:00:00", "dateUpdated": "2024-08-16T18:10:20.544Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-42946
Vulnerability from cvelistv5
Published
2024-08-15 00:00
Modified
2024-08-16 16:55
Severity ?
EPSS score ?
Summary
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromVirtualSer function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
References
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:fh1201_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1201_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.2.0.14(408)" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-42946", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-08-16T16:54:36.613692Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-08-16T16:55:40.491Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromVirtualSer function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-08-15T16:20:50.263049", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1201/fromVirtualSer.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-42946", "datePublished": "2024-08-15T00:00:00", "dateReserved": "2024-08-05T00:00:00", "dateUpdated": "2024-08-16T16:55:40.491Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-42948
Vulnerability from cvelistv5
Published
2024-08-15 00:00
Modified
2024-09-03 17:33
Severity ?
EPSS score ?
Summary
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the delno parameter in the fromPptpUserSetting function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
References
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:fh1201_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1201_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.2.0.14\\(408\\)" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-42948", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-08-19T16:41:53.706340Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-03T17:33:28.798Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the delno parameter in the fromPptpUserSetting function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-08-15T16:20:48.879694", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1201/fromPptpUserSetting.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-42948", "datePublished": "2024-08-15T00:00:00", "dateReserved": "2024-08-05T00:00:00", "dateUpdated": "2024-09-03T17:33:28.798Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-42941
Vulnerability from cvelistv5
Published
2024-08-15 00:00
Modified
2024-09-03 18:12
Severity ?
EPSS score ?
Summary
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the wanmode parameter in the fromAdvSetWan function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
References
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:fh1201_firmware:1.2.0.14:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1201_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.2.0.14" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-42941", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-08-19T17:11:10.329745Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-03T18:12:31.041Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the wanmode parameter in the fromAdvSetWan function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-08-15T16:20:55.919071", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1201/fromAdvSetWan_pptpPPW.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-42941", "datePublished": "2024-08-15T00:00:00", "dateReserved": "2024-08-05T00:00:00", "dateUpdated": "2024-09-03T18:12:31.041Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-42947
Vulnerability from cvelistv5
Published
2024-08-15 00:00
Modified
2024-09-06 16:30
Severity ?
EPSS score ?
Summary
An issue in the handler function in /goform/telnet of Tenda FH1201 v1.2.0.14 (408) allows attackers to execute arbitrary commands via a crafted HTTP request.
References
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:fh1201_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1201_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.2.0.14\\(408\\)" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-42947", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-08-19T16:53:21.789460Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-77", "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-06T16:30:02.299Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "An issue in the handler function in /goform/telnet of Tenda FH1201 v1.2.0.14 (408) allows attackers to execute arbitrary commands via a crafted HTTP request." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-08-15T16:20:49.263011", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1201/telnet.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-42947", "datePublished": "2024-08-15T00:00:00", "dateReserved": "2024-08-05T00:00:00", "dateUpdated": "2024-09-06T16:30:02.299Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-42951
Vulnerability from cvelistv5
Published
2024-08-15 00:00
Modified
2024-08-16 18:04
Severity ?
EPSS score ?
Summary
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the mit_pptpusrpw parameter in the fromWizardHandle function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
References
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:fh1201_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1201_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v1.2.0.14\\/408\\/" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-42951", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-08-16T18:01:21.868174Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400 Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-08-16T18:04:04.439Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the mit_pptpusrpw parameter in the fromWizardHandle function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-08-15T16:20:46.880362", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1201/fromWizardHandle_mit_pptpusrpw.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-42951", "datePublished": "2024-08-15T00:00:00", "dateReserved": "2024-08-05T00:00:00", "dateUpdated": "2024-08-16T18:04:04.439Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-42940
Vulnerability from cvelistv5
Published
2024-08-15 00:00
Modified
2024-09-03 18:18
Severity ?
EPSS score ?
Summary
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromP2pListFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
References
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:fh1201_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1201_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.2.0.14\\(408\\)" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 5.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-42940", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-09-03T18:16:58.474662Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-03T18:18:55.444Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromP2pListFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-08-15T16:20:55.173631", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1201/fromP2pListFilter.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-42940", "datePublished": "2024-08-15T00:00:00", "dateReserved": "2024-08-05T00:00:00", "dateUpdated": "2024-09-03T18:18:55.444Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-42955
Vulnerability from cvelistv5
Published
2024-08-15 00:00
Modified
2024-08-16 16:54
Severity ?
EPSS score ?
Summary
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromSafeClientFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
References
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:fh1201_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1201_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.2.0.14(408)" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-42955", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-08-16T16:53:05.323741Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-08-16T16:54:12.882Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromSafeClientFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-08-15T16:20:44.553012", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1201/fromSafeClientFilter_page.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-42955", "datePublished": "2024-08-15T00:00:00", "dateReserved": "2024-08-05T00:00:00", "dateUpdated": "2024-08-16T16:54:12.882Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-12002
Vulnerability from cvelistv5
Published
2024-11-30 13:00
Modified
2024-12-02 15:54
Severity ?
5.3 (Medium) - CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N
4.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L
4.3 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L
4.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L
4.3 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L
EPSS score ?
Summary
A vulnerability classified as problematic was found in Tenda FH451, FH1201, FH1202 and FH1206 up to 20241129. Affected by this vulnerability is the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
References
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.286417 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.286417 | signature, permissions-required | |
https://vuldb.com/?submit.453974 | third-party-advisory | |
https://github.com/Kalvin2077/tenda-fh-cve | exploit | |
https://www.tenda.com.cn/ | product |
Impacted products
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-12002", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-12-02T15:53:24.555896Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-12-02T15:54:21.033Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "FH451", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241129" } ] }, { "product": "FH1201", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241129" } ] }, { "product": "FH1202", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241129" } ] }, { "product": "FH1206", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241129" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "Kalv1n2077 (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability classified as problematic was found in Tenda FH451, FH1201, FH1202 and FH1206 up to 20241129. Affected by this vulnerability is the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack can be launched remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "de", "value": "In Tenda FH451, FH1201, FH1202 and FH1206 bis 20241129 wurde eine problematische Schwachstelle entdeckt. Betroffen ist die Funktion websReadEvent der Datei /goform/GetIPTV. Durch Beeinflussen des Arguments Content-Length mit unbekannten Daten kann eine null pointer dereference-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 4, "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-476", "description": "NULL Pointer Dereference", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-404", "description": "Denial of Service", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-11-30T13:00:14.751Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-286417 | Tenda FH451/FH1201/FH1202/FH1206 GetIPTV websReadEvent null pointer dereference", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.286417" }, { "name": "VDB-286417 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.286417" }, { "name": "Submit #453974 | Tenda FH451/FH1201/FH1202/FH1206 FH451-V1.0.0.9/FH451-V1.0.0.7/FH451-V1.0.0.5/FH1201-V1.2.0.14(408)_EN/FH1201-V1.2.0.8(8155)/FH1202-V1.2.0.14(408)/etc NULL Pointer Dereference", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.453974" }, { "tags": [ "exploit" ], "url": "https://github.com/Kalvin2077/tenda-fh-cve" }, { "tags": [ "product" ], "url": "https://www.tenda.com.cn/" } ], "timeline": [ { "lang": "en", "time": "2024-11-29T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-11-29T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-11-29T16:54:22.000Z", "value": "VulDB entry last update" } ], "title": "Tenda FH451/FH1201/FH1202/FH1206 GetIPTV websReadEvent null pointer dereference" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-12002", "datePublished": "2024-11-30T13:00:14.751Z", "dateReserved": "2024-11-29T15:49:13.514Z", "dateUpdated": "2024-12-02T15:54:21.033Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-42944
Vulnerability from cvelistv5
Published
2024-08-15 00:00
Modified
2024-08-15 18:03
Severity ?
EPSS score ?
Summary
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromNatlimit function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
References
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:fh1201_firmware:1.2.0.14:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1201_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.2.0.14" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-42944", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-08-15T18:02:46.057654Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-08-15T18:03:46.869Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromNatlimit function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-08-15T16:20:59.007773", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1201/fromNatlimit.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-42944", "datePublished": "2024-08-15T00:00:00", "dateReserved": "2024-08-05T00:00:00", "dateUpdated": "2024-08-15T18:03:46.869Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2024-08-15 17:15
Modified
2024-09-06 17:35
Severity ?
Summary
An issue in the handler function in /goform/telnet of Tenda FH1201 v1.2.0.14 (408) allows attackers to execute arbitrary commands via a crafted HTTP request.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | fh1201_firmware | 1.2.0.14\(408\) | |
tenda | fh1201 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1201_firmware:1.2.0.14\\(408\\):*:*:*:*:*:*:*", "matchCriteriaId": "50F494B8-E1CA-4BA9-8A71-E519EB30CF41", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1201:-:*:*:*:*:*:*:*", "matchCriteriaId": "67A1C59D-AE12-4410-9173-B9B9A72B3AE4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue in the handler function in /goform/telnet of Tenda FH1201 v1.2.0.14 (408) allows attackers to execute arbitrary commands via a crafted HTTP request." }, { "lang": "es", "value": " Un problema en la funci\u00f3n de controlador en /goform/telnet de Tenda FH1201 v1.2.0.14 (408) permite a los atacantes ejecutar comandos arbitrarios a trav\u00e9s de una solicitud HTTP manipulada." } ], "id": "CVE-2024-42947", "lastModified": "2024-09-06T17:35:15.987", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-08-15T17:15:19.187", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit" ], "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1201/telnet.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2024-08-15 17:15
Modified
2024-08-15 19:35
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromNatlimit function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1201/fromNatlimit.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | fh1201_firmware | 1.2.0.14\(408\) | |
tenda | fh1201 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1201_firmware:1.2.0.14\\(408\\):*:*:*:*:*:*:*", "matchCriteriaId": "50F494B8-E1CA-4BA9-8A71-E519EB30CF41", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1201:-:*:*:*:*:*:*:*", "matchCriteriaId": "67A1C59D-AE12-4410-9173-B9B9A72B3AE4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromNatlimit function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request." }, { "lang": "es", "value": " Se descubri\u00f3 que Tenda FH1201 v1.2.0.14 (408) conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro de p\u00e1gina en la funci\u00f3n fromNatlimit. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada." } ], "id": "CVE-2024-42944", "lastModified": "2024-08-15T19:35:13.737", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2024-08-15T17:15:18.903", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1201/fromNatlimit.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2024-08-15 17:15
Modified
2024-08-21 17:35
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the Go parameter in the fromSafeClientFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1201/fromSafeClientFilter_Go.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | fh1201_firmware | 1.2.0.14\(408\) | |
tenda | fh1201 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1201_firmware:1.2.0.14\\(408\\):*:*:*:*:*:*:*", "matchCriteriaId": "50F494B8-E1CA-4BA9-8A71-E519EB30CF41", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1201:-:*:*:*:*:*:*:*", "matchCriteriaId": "67A1C59D-AE12-4410-9173-B9B9A72B3AE4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the Go parameter in the fromSafeClientFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request." }, { "lang": "es", "value": " Se descubri\u00f3 que Tenda FH1201 v1.2.0.14 (408) conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro Go en la funci\u00f3n fromSafeClientFilter. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada." } ], "id": "CVE-2024-42950", "lastModified": "2024-08-21T17:35:04.793", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2024-08-15T17:15:19.497", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1201/fromSafeClientFilter_Go.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2024-08-15 17:15
Modified
2024-09-03 19:35
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
5.7 (Medium) - CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
5.7 (Medium) - CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
Summary
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromP2pListFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1201/fromP2pListFilter.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | fh1201_firmware | 1.2.0.14\(408\) | |
tenda | fh1201 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1201_firmware:1.2.0.14\\(408\\):*:*:*:*:*:*:*", "matchCriteriaId": "50F494B8-E1CA-4BA9-8A71-E519EB30CF41", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1201:-:*:*:*:*:*:*:*", "matchCriteriaId": "67A1C59D-AE12-4410-9173-B9B9A72B3AE4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromP2pListFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request." }, { "lang": "es", "value": " Se descubri\u00f3 que Tenda FH1201 v1.2.0.14 (408) conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro page en la funci\u00f3n fromP2pListFilter. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada." } ], "id": "CVE-2024-42940", "lastModified": "2024-09-03T19:35:15.163", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 5.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.1, "impactScore": 3.6, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2024-08-15T17:15:18.500", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1201/fromP2pListFilter.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2024-08-15 17:15
Modified
2024-08-16 17:35
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromVirtualSer function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1201/fromVirtualSer.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | fh1201_firmware | 1.2.0.14\(408\) | |
tenda | fh1201 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1201_firmware:1.2.0.14\\(408\\):*:*:*:*:*:*:*", "matchCriteriaId": "50F494B8-E1CA-4BA9-8A71-E519EB30CF41", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1201:-:*:*:*:*:*:*:*", "matchCriteriaId": "67A1C59D-AE12-4410-9173-B9B9A72B3AE4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromVirtualSer function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request." }, { "lang": "es", "value": " Se descubri\u00f3 que Tenda FH1201 v1.2.0.14 (408) conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro page en la funci\u00f3n fromVirtualSer. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada." } ], "id": "CVE-2024-42946", "lastModified": "2024-08-16T17:35:08.227", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2024-08-15T17:15:19.097", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1201/fromVirtualSer.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2024-08-15 17:15
Modified
2024-08-16 18:35
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the PPPOEPassword parameter in the fromAdvSetWan function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1201/fromAdvSetWan_PPPOEPassword.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | fh1201_firmware | 1.2.0.14\(408\) | |
tenda | fh1201 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1201_firmware:1.2.0.14\\(408\\):*:*:*:*:*:*:*", "matchCriteriaId": "50F494B8-E1CA-4BA9-8A71-E519EB30CF41", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1201:-:*:*:*:*:*:*:*", "matchCriteriaId": "67A1C59D-AE12-4410-9173-B9B9A72B3AE4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the PPPOEPassword parameter in the fromAdvSetWan function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request." }, { "lang": "es", "value": "Se descubri\u00f3 que Tenda FH1201 v1.2.0.14 (408) conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro PPPOEPassword en la funci\u00f3n fromAdvSetWan. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada." } ], "id": "CVE-2024-42943", "lastModified": "2024-08-16T18:35:13.570", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2024-08-15T17:15:18.800", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1201/fromAdvSetWan_PPPOEPassword.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2024-08-15 17:15
Modified
2024-08-16 18:35
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the mit_pptpusrpw parameter in the fromWizardHandle function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1201/fromWizardHandle_mit_pptpusrpw.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | fh1201_firmware | 1.2.0.14\(408\) | |
tenda | fh1201 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1201_firmware:1.2.0.14\\(408\\):*:*:*:*:*:*:*", "matchCriteriaId": "50F494B8-E1CA-4BA9-8A71-E519EB30CF41", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1201:-:*:*:*:*:*:*:*", "matchCriteriaId": "67A1C59D-AE12-4410-9173-B9B9A72B3AE4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the mit_pptpusrpw parameter in the fromWizardHandle function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request." }, { "lang": "es", "value": "Se descubri\u00f3 que Tenda FH1201 v1.2.0.14 (408) conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro mit_pptpusrpw en la funci\u00f3n fromWizardHandle. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada." } ], "id": "CVE-2024-42951", "lastModified": "2024-08-16T18:35:14.290", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2024-08-15T17:15:19.593", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1201/fromWizardHandle_mit_pptpusrpw.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2024-08-15 17:15
Modified
2024-08-15 19:30
Severity ?
Summary
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromqossetting function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1201/fromqossetting_page.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | fh1201_firmware | 1.2.0.14\(408\) | |
tenda | fh1201 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1201_firmware:1.2.0.14\\(408\\):*:*:*:*:*:*:*", "matchCriteriaId": "50F494B8-E1CA-4BA9-8A71-E519EB30CF41", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1201:-:*:*:*:*:*:*:*", "matchCriteriaId": "67A1C59D-AE12-4410-9173-B9B9A72B3AE4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromqossetting function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request." }, { "lang": "es", "value": " Se descubri\u00f3 que Tenda FH1201 v1.2.0.14 (408) conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro page en la funci\u00f3n fromqossetting. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada." } ], "id": "CVE-2024-42952", "lastModified": "2024-08-15T19:30:38.387", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-08-15T17:15:19.690", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1201/fromqossetting_page.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-08-15 17:15
Modified
2024-09-03 18:35
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the delno parameter in the fromPptpUserSetting function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1201/fromPptpUserSetting.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | fh1201_firmware | 1.2.0.14\(408\) | |
tenda | fh1201 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1201_firmware:1.2.0.14\\(408\\):*:*:*:*:*:*:*", "matchCriteriaId": "50F494B8-E1CA-4BA9-8A71-E519EB30CF41", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1201:-:*:*:*:*:*:*:*", "matchCriteriaId": "67A1C59D-AE12-4410-9173-B9B9A72B3AE4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the delno parameter in the fromPptpUserSetting function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request." }, { "lang": "es", "value": " Se descubri\u00f3 que Tenda FH1201 v1.2.0.14 (408) conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro delno en la funci\u00f3n fromPptpUserSetting. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada." } ], "id": "CVE-2024-42948", "lastModified": "2024-09-03T18:35:12.773", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2024-08-15T17:15:19.287", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1201/fromPptpUserSetting.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2024-08-15 17:15
Modified
2024-08-16 17:35
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromSafeClientFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1201/fromSafeClientFilter_page.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | fh1201_firmware | 1.2.0.14\(408\) | |
tenda | fh1201 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1201_firmware:1.2.0.14\\(408\\):*:*:*:*:*:*:*", "matchCriteriaId": "50F494B8-E1CA-4BA9-8A71-E519EB30CF41", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1201:-:*:*:*:*:*:*:*", "matchCriteriaId": "67A1C59D-AE12-4410-9173-B9B9A72B3AE4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromSafeClientFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request." }, { "lang": "es", "value": " Se descubri\u00f3 que Tenda FH1201 v1.2.0.14 (408) conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro page en la funci\u00f3n fromSafeClientFilter. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada." } ], "id": "CVE-2024-42955", "lastModified": "2024-08-16T17:35:08.957", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2024-08-15T17:15:19.990", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1201/fromSafeClientFilter_page.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2024-08-15 17:15
Modified
2024-09-03 19:35
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the wanmode parameter in the fromAdvSetWan function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1201/fromAdvSetWan_pptpPPW.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | fh1201_firmware | 1.2.0.14\(408\) | |
tenda | fh1201 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1201_firmware:1.2.0.14\\(408\\):*:*:*:*:*:*:*", "matchCriteriaId": "50F494B8-E1CA-4BA9-8A71-E519EB30CF41", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1201:-:*:*:*:*:*:*:*", "matchCriteriaId": "67A1C59D-AE12-4410-9173-B9B9A72B3AE4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the wanmode parameter in the fromAdvSetWan function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request." }, { "lang": "es", "value": " Se descubri\u00f3 que Tenda FH1201 v1.2.0.14 (408) conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro wanmode en la funci\u00f3n fromAdvSetWan. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada." } ], "id": "CVE-2024-42941", "lastModified": "2024-09-03T19:35:15.967", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2024-08-15T17:15:18.603", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1201/fromAdvSetWan_pptpPPW.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2024-11-30 13:15
Modified
2024-12-10 23:21
Severity ?
4.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
Summary
A vulnerability classified as problematic was found in Tenda FH451, FH1201, FH1202 and FH1206 up to 20241129. Affected by this vulnerability is the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
References
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/Kalvin2077/tenda-fh-cve | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.286417 | Permissions Required, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.286417 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.453974 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://www.tenda.com.cn/ | Product |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | fh451_firmware | 1.0.0.5 | |
tenda | fh451_firmware | 1.0.0.7 | |
tenda | fh451_firmware | 1.0.0.9 | |
tenda | fh451 | - | |
tenda | fh1201_firmware | 1.2.0.8\(8155\) | |
tenda | fh1201_firmware | 1.2.0.14\(408\)_en | |
tenda | fh1201 | - | |
tenda | fh1202_firmware | 1.2.0.9 | |
tenda | fh1202_firmware | 1.2.0.14\(408\) | |
tenda | fh1202_firmware | 1.2.0.14\(408\)_en | |
tenda | fh1202 | - | |
tenda | fh1206_firmware | 1.2.0.8\(8155\) | |
tenda | fh1206 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh451_firmware:1.0.0.5:*:*:*:*:*:*:*", "matchCriteriaId": "645BB5C8-F542-4D2A-81EB-168982028C42", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:fh451_firmware:1.0.0.7:*:*:*:*:*:*:*", "matchCriteriaId": "7587331C-8CDC-43FA-869B-CACC9E39CC4F", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:fh451_firmware:1.0.0.9:*:*:*:*:*:*:*", "matchCriteriaId": "A7521568-7BCD-43F8-9F20-440DF3919D5D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh451:-:*:*:*:*:*:*:*", "matchCriteriaId": "97A8BF83-E42A-4D6B-A52D-146FE1AEE2B0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1201_firmware:1.2.0.8\\(8155\\):*:*:*:*:*:*:*", "matchCriteriaId": "0368A8C0-C2C0-477E-A0C2-4D941B963520", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:fh1201_firmware:1.2.0.14\\(408\\)_en:*:*:*:*:*:*:*", "matchCriteriaId": "84F68F46-077A-48C8-AA85-342A2264BF1C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1201:-:*:*:*:*:*:*:*", "matchCriteriaId": "67A1C59D-AE12-4410-9173-B9B9A72B3AE4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1202_firmware:1.2.0.9:*:*:*:*:*:*:*", "matchCriteriaId": "9DA584AC-7E1F-4FF7-91EA-F82AC2D2D3CC", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:fh1202_firmware:1.2.0.14\\(408\\):*:*:*:*:*:*:*", "matchCriteriaId": "B9FD9D0A-39F4-4AD8-AEE0-71C9E77D2799", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:fh1202_firmware:1.2.0.14\\(408\\)_en:*:*:*:*:*:*:*", "matchCriteriaId": "9A318B1F-C8E5-4C39-A1B3-83C5693CEB61", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1202:-:*:*:*:*:*:*:*", "matchCriteriaId": "4A632A11-60A0-457C-A039-BED32F83BD52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1206_firmware:1.2.0.8\\(8155\\):*:*:*:*:*:*:*", "matchCriteriaId": "066BD21A-2694-474D-B885-6E9A2A1DBCFF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*", "matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability classified as problematic was found in Tenda FH451, FH1201, FH1202 and FH1206 up to 20241129. Affected by this vulnerability is the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack can be launched remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "es", "value": "Se ha detectado una vulnerabilidad clasificada como problem\u00e1tica en Tenda FH451, FH1201, FH1202 y FH1206 hasta 20241129. Esta vulnerabilidad afecta a la funci\u00f3n websReadEvent del archivo /goform/GetIPTV. La manipulaci\u00f3n del argumento Content-Length provoca la desreferenciaci\u00f3n de un puntero nulo. El ataque puede ejecutarse de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse." } ], "id": "CVE-2024-12002", "lastModified": "2024-12-10T23:21:19.827", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 4.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 4.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 1.4, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "automatable": "NOT_DEFINED", "availabilityRequirements": "NOT_DEFINED", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityRequirements": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirements": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubsequentSystemAvailability": "NOT_DEFINED", "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED", "modifiedSubsequentSystemIntegrity": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnerableSystemAvailability": "NOT_DEFINED", "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED", "modifiedVulnerableSystemIntegrity": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "recovery": "NOT_DEFINED", "safety": "NOT_DEFINED", "subsequentSystemAvailability": "NONE", "subsequentSystemConfidentiality": "NONE", "subsequentSystemIntegrity": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnerabilityResponseEffort": "NOT_DEFINED", "vulnerableSystemAvailability": "LOW", "vulnerableSystemConfidentiality": "NONE", "vulnerableSystemIntegrity": "NONE" }, "source": "cna@vuldb.com", "type": "Secondary" } ] }, "published": "2024-11-30T13:15:04.610", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/Kalvin2077/tenda-fh-cve" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.286417" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.286417" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.453974" }, { "source": "cna@vuldb.com", "tags": [ "Product" ], "url": "https://www.tenda.com.cn/" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-404" }, { "lang": "en", "value": "CWE-476" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-476" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
var-202409-2018
Vulnerability from variot
Tenda FH1201 v1.2.0.14 has a stack buffer overflow vulnerability in formWrlExtraGet
. Tenda FH1201 is a wireless router from China's Tenda company. No detailed vulnerability details are provided at present
{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202409-2018", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "fh1201", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "v1.2.0.14" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-40285" } ] }, "cve": "CVE-2024-44859", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.7, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 5.1, "id": "CNVD-2024-40285", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "availabilityImpact": "HIGH", "baseScore": 8.0, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.1, "id": "CVE-2024-44859", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "id": "CVE-2024-44859", "trust": 1.0, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2024-40285", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-40285" }, { "db": "NVD", "id": "CVE-2024-44859" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda FH1201 v1.2.0.14 has a stack buffer overflow vulnerability in `formWrlExtraGet`. Tenda FH1201 is a wireless router from China\u0027s Tenda company. No detailed vulnerability details are provided at present", "sources": [ { "db": "NVD", "id": "CVE-2024-44859" }, { "db": "CNVD", "id": "CNVD-2024-40285" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2024-44859", "trust": 1.6 }, { "db": "CNVD", "id": "CNVD-2024-40285", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-40285" }, { "db": "NVD", "id": "CVE-2024-44859" } ] }, "id": "VAR-202409-2018", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-40285" } ], "trust": 0.06 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-40285" } ] }, "last_update_date": "2024-10-13T23:04:19.122000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-121", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2024-44859" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.0, "url": "https://github.com/ha0-y/iot/blob/main/tenda-f1201/wrlextraget.md" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2024-44859/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-40285" }, { "db": "NVD", "id": "CVE-2024-44859" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-40285" }, { "db": "NVD", "id": "CVE-2024-44859" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-10-10T00:00:00", "db": "CNVD", "id": "CNVD-2024-40285" }, { "date": "2024-09-04T16:15:07.400000", "db": "NVD", "id": "CVE-2024-44859" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-10-11T00:00:00", "db": "CNVD", "id": "CNVD-2024-40285" }, { "date": "2024-09-05T12:53:21.110000", "db": "NVD", "id": "CVE-2024-44859" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda FH1201 has an unspecified vulnerability (CNVD-2024-40285)", "sources": [ { "db": "CNVD", "id": "CNVD-2024-40285" } ], "trust": 0.6 } }