Vulnerabilites related to siemens - 6gk1411-1ac00
Vulnerability from fkie_nvd
Published
2023-05-09 13:15
Modified
2024-11-21 07:56
Summary
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1). The web based management of affected devices does not properly validate user input, making it susceptible to command injection. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6gk1411-1ac00_firmware:2.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1F685FA-A737-4D3D-AF47-837D30EBD898",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6gk1411-1ac00:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A62A87CC-250C-469E-9D2C-187271020EE6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6gk1411-5ac00_firmware:2.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "CAD8CE67-41F5-4673-BC79-EF290971FF20",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6gk1411-5ac00:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7804B194-FECA-4D73-9D49-4B7E8FD49258",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions \u003e= V2.0 \u003c V2.1), SIMATIC Cloud Connect 7 CC716 (All versions \u003e= V2.0 \u003c V2.1). The web based management of affected devices does not properly validate user input, making it susceptible to command injection. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges."
    }
  ],
  "id": "CVE-2023-28832",
  "lastModified": "2024-11-21T07:56:06.930",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.2,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-05-09T13:15:17.373",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-05-09 13:15
Modified
2024-11-21 07:56
Summary
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC712 (All versions < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions < V2.1). The affected device is vulnerable to a denial of service while parsing a random (non-JSON) MQTT payload. This could allow an attacker who can manipulate the communication between the MQTT broker and the affected device to cause a denial of service (DoS).



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6gk1411-1ac00_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F167D4D5-349A-4A2B-90E8-7EF29991F135",
              "versionEndExcluding": "2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6gk1411-1ac00:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A62A87CC-250C-469E-9D2C-187271020EE6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6gk1411-5ac00_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3DFB8EBF-5050-4AA9-8BD1-51CC51E9E4CB",
              "versionEndExcluding": "2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6gk1411-5ac00:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7804B194-FECA-4D73-9D49-4B7E8FD49258",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions \u003e= V2.0 \u003c V2.1), SIMATIC Cloud Connect 7 CC712 (All versions \u003c V2.1), SIMATIC Cloud Connect 7 CC716 (All versions \u003e= V2.0 \u003c V2.1), SIMATIC Cloud Connect 7 CC716 (All versions \u003c V2.1). The affected device is vulnerable to a denial of service while parsing a random (non-JSON) MQTT payload. This could allow an attacker who can manipulate the communication between the MQTT broker and the affected device to cause a denial of service (DoS)."
    }
  ],
  "id": "CVE-2023-29105",
  "lastModified": "2024-11-21T07:56:33.467",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 5.9,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.2,
        "impactScore": 3.6,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-05-09T13:15:17.627",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-544"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-05-09 13:15
Modified
2024-11-21 07:56
Summary
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1). The filename in the upload feature of the web based management of the affected device is susceptible to a path traversal vulnerability. This could allow an authenticated privileged remote attacker to write any file with the extension `.db`.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6gk1411-1ac00_firmware:2.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1F685FA-A737-4D3D-AF47-837D30EBD898",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6gk1411-1ac00:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A62A87CC-250C-469E-9D2C-187271020EE6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6gk1411-5ac00_firmware:2.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "CAD8CE67-41F5-4673-BC79-EF290971FF20",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6gk1411-5ac00:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7804B194-FECA-4D73-9D49-4B7E8FD49258",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions \u003e= V2.0 \u003c V2.1), SIMATIC Cloud Connect 7 CC716 (All versions \u003e= V2.0 \u003c V2.1). The filename in the upload feature of the web based management of the affected device is susceptible to a path traversal vulnerability. This could allow an authenticated privileged remote attacker to write any file with the extension `.db`."
    }
  ],
  "id": "CVE-2023-29128",
  "lastModified": "2024-11-21T07:56:35.560",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "LOW",
          "baseScore": 3.8,
          "baseSeverity": "LOW",
          "confidentialityImpact": "NONE",
          "integrityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:L",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 2.5,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 2.7,
          "baseSeverity": "LOW",
          "confidentialityImpact": "NONE",
          "integrityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 1.4,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-05-09T13:15:17.843",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-22"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-05-09 13:15
Modified
2024-11-21 07:56
Summary
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC712 (All versions < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions < V2.1). The affected device uses a hard-coded password to protect the diagnostic files. This could allow an authenticated attacker to access protected data.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6gk1411-1ac00_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F167D4D5-349A-4A2B-90E8-7EF29991F135",
              "versionEndExcluding": "2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6gk1411-1ac00:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A62A87CC-250C-469E-9D2C-187271020EE6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6gk1411-5ac00_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3DFB8EBF-5050-4AA9-8BD1-51CC51E9E4CB",
              "versionEndExcluding": "2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6gk1411-5ac00:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7804B194-FECA-4D73-9D49-4B7E8FD49258",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions \u003e= V2.0 \u003c V2.1), SIMATIC Cloud Connect 7 CC712 (All versions \u003c V2.1), SIMATIC Cloud Connect 7 CC716 (All versions \u003e= V2.0 \u003c V2.1), SIMATIC Cloud Connect 7 CC716 (All versions \u003c V2.1). The affected device uses a hard-coded password to protect the diagnostic files. This could allow an authenticated attacker to access protected data."
    }
  ],
  "id": "CVE-2023-29103",
  "lastModified": "2024-11-21T07:56:33.217",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 1.4,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-05-09T13:15:17.447",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-259"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-05-09 13:15
Modified
2024-11-21 07:56
Summary
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1). The filename in the upload feature of the web based management of the affected device is susceptible to a path traversal vulnerability. This could allow an authenticated privileged remote attacker to overwrite any file the Linux user `ccuser` has write access to, or to download any file the Linux user `ccuser` has read-only access to.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6gk1411-1ac00_firmware:2.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1F685FA-A737-4D3D-AF47-837D30EBD898",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6gk1411-1ac00:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A62A87CC-250C-469E-9D2C-187271020EE6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6gk1411-5ac00_firmware:2.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "CAD8CE67-41F5-4673-BC79-EF290971FF20",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6gk1411-5ac00:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7804B194-FECA-4D73-9D49-4B7E8FD49258",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions \u003e= V2.0 \u003c V2.1), SIMATIC Cloud Connect 7 CC716 (All versions \u003e= V2.0 \u003c V2.1). The filename in the upload feature of the web based management of the affected device is susceptible to a path traversal vulnerability. This could allow an authenticated privileged remote attacker to overwrite any file the Linux user `ccuser` has write access to, or to download any file the Linux user `ccuser` has read-only access to."
    }
  ],
  "id": "CVE-2023-29104",
  "lastModified": "2024-11-21T07:56:33.347",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.0,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 4.7,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.6,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 4.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-05-09T13:15:17.547",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-22"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-05-09 13:15
Modified
2024-11-21 07:56
Summary
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1). The export endpoint discloses some undocumented files. This could allow an unauthenticated remote attacker to gain access to additional information resources.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6gk1411-1ac00_firmware:2.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1F685FA-A737-4D3D-AF47-837D30EBD898",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6gk1411-1ac00:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A62A87CC-250C-469E-9D2C-187271020EE6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6gk1411-5ac00_firmware:2.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "CAD8CE67-41F5-4673-BC79-EF290971FF20",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6gk1411-5ac00:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7804B194-FECA-4D73-9D49-4B7E8FD49258",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions \u003e= V2.0 \u003c V2.1), SIMATIC Cloud Connect 7 CC716 (All versions \u003e= V2.0 \u003c V2.1). The export endpoint discloses some undocumented files. This could allow an unauthenticated remote attacker to gain access to additional information resources."
    }
  ],
  "id": "CVE-2023-29107",
  "lastModified": "2024-11-21T07:56:33.703",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 1.4,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-05-09T13:15:17.777",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-552"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-552"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-05-09 13:15
Modified
2024-11-21 07:56
Summary
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1). The export endpoint is accessible via REST API without authentication. This could allow an unauthenticated remote attacker to download the files available via the endpoint.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6gk1411-1ac00_firmware:2.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1F685FA-A737-4D3D-AF47-837D30EBD898",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6gk1411-1ac00:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A62A87CC-250C-469E-9D2C-187271020EE6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6gk1411-5ac00_firmware:2.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "CAD8CE67-41F5-4673-BC79-EF290971FF20",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6gk1411-5ac00:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7804B194-FECA-4D73-9D49-4B7E8FD49258",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions \u003e= V2.0 \u003c V2.1), SIMATIC Cloud Connect 7 CC716 (All versions \u003e= V2.0 \u003c V2.1). The export endpoint is accessible via REST API without authentication. This could allow an unauthenticated remote attacker to download the files available via the endpoint."
    }
  ],
  "id": "CVE-2023-29106",
  "lastModified": "2024-11-21T07:56:33.583",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 1.4,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-05-09T13:15:17.703",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-200"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

var-202305-0430
Vulnerability from variot

A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1). The web based management of affected devices does not properly validate user input, making it susceptible to command injection. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges. Siemens' 6gk1411-1ac00 firmware and 6gk1411-5ac00 Firmware contains a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. SIMATIC Cloud Connect 7 is an IoT gateway for connecting programmable logic controllers to cloud services and allows field devices to be interfaced with OPC UA servers as OPC UA clients

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202305-0430",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "6gk1411-1ac00",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.0"
      },
      {
        "model": "6gk1411-5ac00",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.0"
      },
      {
        "model": "6gk1411-5ac00",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "6gk1411-1ac00",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "simatic cloud connect cc716",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "7\u003e=v2.0,\u003cv2.1"
      },
      {
        "model": "simatic cloud connect cc712",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "7\u003e=v2.0,\u003cv2.1"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-35774"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-009653"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-28832"
      }
    ]
  },
  "cve": "CVE-2023-28832",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2023-35774",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "productcert@siemens.com",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.2,
            "id": "CVE-2023-28832",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "OTHER",
            "availabilityImpact": "High",
            "baseScore": 7.2,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2023-009653",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "High",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "productcert@siemens.com",
            "id": "CVE-2023-28832",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2023-009653",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2023-35774",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202305-650",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-35774"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-009653"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-650"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-28832"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions \u003e= V2.0 \u003c V2.1), SIMATIC Cloud Connect 7 CC716 (All versions \u003e= V2.0 \u003c V2.1). The web based management of affected devices does not properly validate user input, making it susceptible to command injection. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges. Siemens\u0027 6gk1411-1ac00 firmware and 6gk1411-5ac00 Firmware contains a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. SIMATIC Cloud Connect 7 is an IoT gateway for connecting programmable logic controllers to cloud services and allows field devices to be interfaced with OPC UA servers as OPC UA clients",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-28832"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-009653"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-35774"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-28832"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-28832",
        "trust": 3.9
      },
      {
        "db": "SIEMENS",
        "id": "SSA-555292",
        "trust": 3.1
      },
      {
        "db": "JVN",
        "id": "JVNVU98195668",
        "trust": 0.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-23-131-04",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-009653",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-35774",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-650",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-28832",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-35774"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-28832"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-009653"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-650"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-28832"
      }
    ]
  },
  "id": "VAR-202305-0430",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-35774"
      }
    ],
    "trust": 0.06
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-35774"
      }
    ]
  },
  "last_update_date": "2024-08-14T12:04:34.126000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Siemens SIMATIC Cloud Connect 7 Command Injection Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/424686"
      },
      {
        "title": "Siemens SIMATIC Cloud Connect Fixes for command injection vulnerabilities",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=237051"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-35774"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-650"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-77",
        "trust": 1.0
      },
      {
        "problemtype": "Command injection (CWE-77) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-009653"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-28832"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-28832"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu98195668/"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-131-04"
      },
      {
        "trust": 0.6,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-555292.html"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2023-28832/"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/77.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-35774"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-28832"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-009653"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-650"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-28832"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-35774"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-28832"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-009653"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-650"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-28832"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-05-10T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-35774"
      },
      {
        "date": "2023-05-09T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-28832"
      },
      {
        "date": "2023-12-06T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-009653"
      },
      {
        "date": "2023-05-09T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202305-650"
      },
      {
        "date": "2023-05-09T13:15:17.373000",
        "db": "NVD",
        "id": "CVE-2023-28832"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-05-10T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-35774"
      },
      {
        "date": "2023-05-09T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-28832"
      },
      {
        "date": "2023-12-06T05:17:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-009653"
      },
      {
        "date": "2023-05-11T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202305-650"
      },
      {
        "date": "2023-05-15T18:49:38.067000",
        "db": "NVD",
        "id": "CVE-2023-28832"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-650"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens\u0027 \u00a06gk1411-1ac00\u00a0 firmware and \u00a06gk1411-5ac00\u00a0 Command injection vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-009653"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "command injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-650"
      }
    ],
    "trust": 0.6
  }
}

cve-2023-29107
Vulnerability from cvelistv5
Published
2023-05-09 11:51
Modified
2025-01-28 18:37
Summary
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1). The export endpoint discloses some undocumented files. This could allow an unauthenticated remote attacker to gain access to additional information resources.
Impacted products
Vendor Product Version
Siemens SIMATIC Cloud Connect 7 CC712 Version: All versions >= V2.0 < V2.1
Create a notification for this product.
   Siemens SIMATIC Cloud Connect 7 CC716 Version: All versions >= V2.0 < V2.1
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:00:15.963Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-29107",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-28T18:36:48.515301Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-28T18:37:13.123Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Cloud Connect 7 CC712",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Cloud Connect 7 CC716",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions \u003e= V2.0 \u003c V2.1), SIMATIC Cloud Connect 7 CC716 (All versions \u003e= V2.0 \u003c V2.1). The export endpoint discloses some undocumented files. This could allow an unauthenticated remote attacker to gain access to additional information resources."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-552",
              "description": "CWE-552: Files or Directories Accessible to External Parties",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-09T11:51:34.269Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-29107",
    "datePublished": "2023-05-09T11:51:34.269Z",
    "dateReserved": "2023-03-31T08:06:09.775Z",
    "dateUpdated": "2025-01-28T18:37:13.123Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-29106
Vulnerability from cvelistv5
Published
2023-05-09 11:51
Modified
2025-01-28 18:38
Summary
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1). The export endpoint is accessible via REST API without authentication. This could allow an unauthenticated remote attacker to download the files available via the endpoint.
Impacted products
Vendor Product Version
Siemens SIMATIC Cloud Connect 7 CC712 Version: All versions >= V2.0 < V2.1
Create a notification for this product.
   Siemens SIMATIC Cloud Connect 7 CC716 Version: All versions >= V2.0 < V2.1
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:00:15.596Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-29106",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-28T18:38:46.301373Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-28T18:38:53.788Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Cloud Connect 7 CC712",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Cloud Connect 7 CC716",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions \u003e= V2.0 \u003c V2.1), SIMATIC Cloud Connect 7 CC716 (All versions \u003e= V2.0 \u003c V2.1). The export endpoint is accessible via REST API without authentication. This could allow an unauthenticated remote attacker to download the files available via the endpoint."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-09T11:51:33.140Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-29106",
    "datePublished": "2023-05-09T11:51:33.140Z",
    "dateReserved": "2023-03-31T08:06:09.775Z",
    "dateUpdated": "2025-01-28T18:38:53.788Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-29104
Vulnerability from cvelistv5
Published
2023-05-09 11:51
Modified
2025-01-28 18:41
Summary
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1). The filename in the upload feature of the web based management of the affected device is susceptible to a path traversal vulnerability. This could allow an authenticated privileged remote attacker to overwrite any file the Linux user `ccuser` has write access to, or to download any file the Linux user `ccuser` has read-only access to.
Impacted products
Vendor Product Version
Siemens SIMATIC Cloud Connect 7 CC712 Version: All versions >= V2.0 < V2.1
Create a notification for this product.
   Siemens SIMATIC Cloud Connect 7 CC716 Version: All versions >= V2.0 < V2.1
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:00:15.849Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-29104",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-28T18:40:54.262878Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-28T18:41:04.237Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Cloud Connect 7 CC712",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Cloud Connect 7 CC716",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions \u003e= V2.0 \u003c V2.1), SIMATIC Cloud Connect 7 CC716 (All versions \u003e= V2.0 \u003c V2.1). The filename in the upload feature of the web based management of the affected device is susceptible to a path traversal vulnerability. This could allow an authenticated privileged remote attacker to overwrite any file the Linux user `ccuser` has write access to, or to download any file the Linux user `ccuser` has read-only access to."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-22",
              "description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-09T11:51:30.950Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-29104",
    "datePublished": "2023-05-09T11:51:30.950Z",
    "dateReserved": "2023-03-31T08:06:09.775Z",
    "dateUpdated": "2025-01-28T18:41:04.237Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-29105
Vulnerability from cvelistv5
Published
2023-05-09 11:51
Modified
2025-01-28 18:40
Summary
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC712 (All versions < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions < V2.1). The affected device is vulnerable to a denial of service while parsing a random (non-JSON) MQTT payload. This could allow an attacker who can manipulate the communication between the MQTT broker and the affected device to cause a denial of service (DoS).
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:00:15.875Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-29105",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-28T18:40:10.111613Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-28T18:40:19.563Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Cloud Connect 7 CC712",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Cloud Connect 7 CC712",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Cloud Connect 7 CC716",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Cloud Connect 7 CC716",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions \u003e= V2.0 \u003c V2.1), SIMATIC Cloud Connect 7 CC712 (All versions \u003c V2.1), SIMATIC Cloud Connect 7 CC716 (All versions \u003e= V2.0 \u003c V2.1), SIMATIC Cloud Connect 7 CC716 (All versions \u003c V2.1). The affected device is vulnerable to a denial of service while parsing a random (non-JSON) MQTT payload. This could allow an attacker who can manipulate the communication between the MQTT broker and the affected device to cause a denial of service (DoS)."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-544",
              "description": "CWE-544: Missing Standardized Error Handling Mechanism",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-09T11:51:32.057Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-29105",
    "datePublished": "2023-05-09T11:51:32.057Z",
    "dateReserved": "2023-03-31T08:06:09.775Z",
    "dateUpdated": "2025-01-28T18:40:19.563Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-29103
Vulnerability from cvelistv5
Published
2023-05-09 11:51
Modified
2025-01-28 18:41
Summary
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC712 (All versions < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions < V2.1). The affected device uses a hard-coded password to protect the diagnostic files. This could allow an authenticated attacker to access protected data.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:00:15.546Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-29103",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-28T18:41:26.844912Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-28T18:41:36.064Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Cloud Connect 7 CC712",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Cloud Connect 7 CC712",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Cloud Connect 7 CC716",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Cloud Connect 7 CC716",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions \u003e= V2.0 \u003c V2.1), SIMATIC Cloud Connect 7 CC712 (All versions \u003c V2.1), SIMATIC Cloud Connect 7 CC716 (All versions \u003e= V2.0 \u003c V2.1), SIMATIC Cloud Connect 7 CC716 (All versions \u003c V2.1). The affected device uses a hard-coded password to protect the diagnostic files. This could allow an authenticated attacker to access protected data."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-259",
              "description": "CWE-259: Use of Hard-coded Password",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-09T11:51:29.860Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-29103",
    "datePublished": "2023-05-09T11:51:29.860Z",
    "dateReserved": "2023-03-31T08:06:09.775Z",
    "dateUpdated": "2025-01-28T18:41:36.064Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-29128
Vulnerability from cvelistv5
Published
2023-05-09 11:51
Modified
2025-01-28 18:36
Summary
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1). The filename in the upload feature of the web based management of the affected device is susceptible to a path traversal vulnerability. This could allow an authenticated privileged remote attacker to write any file with the extension `.db`.
Impacted products
Vendor Product Version
Siemens SIMATIC Cloud Connect 7 CC712 Version: All versions >= V2.0 < V2.1
Create a notification for this product.
   Siemens SIMATIC Cloud Connect 7 CC716 Version: All versions >= V2.0 < V2.1
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:00:15.230Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-29128",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-28T18:36:08.750699Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-28T18:36:17.506Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Cloud Connect 7 CC712",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Cloud Connect 7 CC716",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions \u003e= V2.0 \u003c V2.1), SIMATIC Cloud Connect 7 CC716 (All versions \u003e= V2.0 \u003c V2.1). The filename in the upload feature of the web based management of the affected device is susceptible to a path traversal vulnerability. This could allow an authenticated privileged remote attacker to write any file with the extension `.db`."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 3.8,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:L/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-22",
              "description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-09T11:51:35.346Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-29128",
    "datePublished": "2023-05-09T11:51:35.346Z",
    "dateReserved": "2023-03-31T10:54:25.289Z",
    "dateUpdated": "2025-01-28T18:36:17.506Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-28832
Vulnerability from cvelistv5
Published
2023-05-09 11:51
Modified
2025-01-28 18:42
Summary
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1). The web based management of affected devices does not properly validate user input, making it susceptible to command injection. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.
Impacted products
Vendor Product Version
Siemens SIMATIC Cloud Connect 7 CC712 Version: All versions >= V2.0 < V2.1
Create a notification for this product.
   Siemens SIMATIC Cloud Connect 7 CC716 Version: All versions >= V2.0 < V2.1
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T13:51:38.923Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-28832",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-28T18:42:31.147318Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-28T18:42:40.340Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Cloud Connect 7 CC712",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Cloud Connect 7 CC716",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions \u003e= V2.0 \u003c V2.1), SIMATIC Cloud Connect 7 CC716 (All versions \u003e= V2.0 \u003c V2.1). The web based management of affected devices does not properly validate user input, making it susceptible to command injection. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-09T11:51:28.740Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-28832",
    "datePublished": "2023-05-09T11:51:28.740Z",
    "dateReserved": "2023-03-24T15:17:33.934Z",
    "dateUpdated": "2025-01-28T18:42:40.340Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}