Common Weakness Enumeration

CWE-703

Discouraged

Improper Check or Handling of Exceptional Conditions

Abstraction: Pillar · Status: Incomplete

The product does not properly anticipate or handle exceptional conditions that rarely occur during normal operation of the product.

217 vulnerabilities reference this CWE, most recent first.

CVE-2020-1639 (GCVE-0-2020-1639)

Vulnerability from cvelistv5 – Published: 2020-04-08 19:26 – Updated: 2024-09-16 22:02
VLAI
Title
Junos OS: A crafted Ethernet OAM packet received by Junos may cause the Ethernet OAM connectivity fault management process (CFM) to core.
Summary
When an attacker sends a specific crafted Ethernet Operation, Administration, and Maintenance (Ethernet OAM) packet to a target device, it may improperly handle the incoming malformed data and fail to sanitize this incoming data resulting in an overflow condition. This overflow condition in Juniper Networks Junos OS allows an attacker to cause a Denial of Service (DoS) condition by coring the CFM daemon. Continued receipt of these packets may cause an extended Denial of Service condition. This issue affects: Juniper Networks Junos OS 12.3 versions prior to 12.3R12-S15; 12.3X48 versions prior to 12.3X48-D95 on SRX Series; 14.1X50 versions prior to 14.1X50-D145; 14.1X53 versions prior to 14.1X53-D47; 15.1 versions prior to 15.1R2; 15.1X49 versions prior to 15.1X49-D170 on SRX Series; 15.1X53 versions prior to 15.1X53-D67.
CWE
  • CWE-703 - Improper Check or Handling of Exceptional Conditions
Assigner
References
URL Tags
https://kb.juniper.net/ x_refsource_MISC
Impacted products
Vendor Product Version
Juniper Networks Junos OS Affected: 12.3 , < 12.3R12-S15 (custom)
Affected: 14.1X50 , < 14.1X50-D145 (custom)
Affected: 14.1X53 , < 14.1X53-D47 (custom)
Affected: 15.1 , < 15.1R2 (custom)
Affected: 15.1X53 , < 15.1X53-D67 (custom)
Create a notification for this product.
Juniper Networks Junos OS Affected: 12.3X48 , < 12.3X48-D95 (custom)
Affected: 15.1X49 , < 15.1X49-D170 (custom)
Create a notification for this product.
Date Public
2020-04-08 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T06:46:30.869Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://kb.juniper.net/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Junos OS",
          "vendor": "Juniper Networks",
          "versions": [
            {
              "lessThan": "12.3R12-S15",
              "status": "affected",
              "version": "12.3",
              "versionType": "custom"
            },
            {
              "lessThan": "14.1X50-D145",
              "status": "affected",
              "version": "14.1X50",
              "versionType": "custom"
            },
            {
              "lessThan": "14.1X53-D47",
              "status": "affected",
              "version": "14.1X53",
              "versionType": "custom"
            },
            {
              "lessThan": "15.1R2",
              "status": "affected",
              "version": "15.1",
              "versionType": "custom"
            },
            {
              "lessThan": "15.1X53-D67",
              "status": "affected",
              "version": "15.1X53",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "SRX Series"
          ],
          "product": "Junos OS",
          "vendor": "Juniper Networks",
          "versions": [
            {
              "lessThan": "12.3X48-D95",
              "status": "affected",
              "version": "12.3X48",
              "versionType": "custom"
            },
            {
              "lessThan": "15.1X49-D170",
              "status": "affected",
              "version": "15.1X49",
              "versionType": "custom"
            }
          ]
        }
      ],
      "configurations": [
        {
          "lang": "en",
          "value": "This issue affects Junos OS devices with OAM Ethernet configured:\n\n  [protocols oam ethernet connectivity-fault-management]"
        }
      ],
      "datePublic": "2020-04-08T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "When an attacker sends a specific crafted Ethernet Operation, Administration, and Maintenance (Ethernet OAM) packet to a target device, it may improperly handle the incoming malformed data and fail to sanitize this incoming data resulting in an overflow condition. This overflow condition in Juniper Networks Junos OS allows an attacker to cause a Denial of Service (DoS) condition by coring the CFM daemon. Continued receipt of these packets may cause an extended Denial of Service condition. This issue affects: Juniper Networks Junos OS 12.3 versions prior to 12.3R12-S15; 12.3X48 versions prior to 12.3X48-D95 on SRX Series; 14.1X50 versions prior to 14.1X50-D145; 14.1X53 versions prior to 14.1X53-D47; 15.1 versions prior to 15.1R2; 15.1X49 versions prior to 15.1X49-D170 on SRX Series; 15.1X53 versions prior to 15.1X53-D67."
        }
      ],
      "exploits": [
        {
          "lang": "en",
          "value": "Juniper SIRT is not aware of any malicious exploitation of this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-703",
              "description": "CWE-703 Improper Check or Handling of Exceptional Conditions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-04-08T19:26:02.000Z",
        "orgId": "8cbe9d5a-a066-4c94-8978-4b15efeae968",
        "shortName": "juniper"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://kb.juniper.net/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "The following software releases have been updated to resolve this specific issue: 12.3R12-S15, 12.3X48-D95, 14.1X50-D145, 14.1X53-D47, 15.1R2, 15.1X49-D170, 16.1R1, and all subsequent releases."
        }
      ],
      "source": {
        "advisory": "JSA11020",
        "defect": [
          "999503"
        ],
        "discovery": "INTERNAL"
      },
      "title": "Junos OS: A crafted Ethernet OAM packet received by Junos may cause the Ethernet OAM connectivity fault management process (CFM) to core.",
      "workarounds": [
        {
          "lang": "en",
          "value": "There are no viable workarounds for this issue."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "sirt@juniper.net",
          "DATE_PUBLIC": "2020-04-08T15:00:00.000Z",
          "ID": "CVE-2020-1639",
          "STATE": "PUBLIC",
          "TITLE": "Junos OS: A crafted Ethernet OAM packet received by Junos may cause the Ethernet OAM connectivity fault management process (CFM) to core."
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Junos OS",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "12.3",
                            "version_value": "12.3R12-S15"
                          },
                          {
                            "platform": "SRX Series",
                            "version_affected": "\u003c",
                            "version_name": "12.3X48",
                            "version_value": "12.3X48-D95"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "14.1X50",
                            "version_value": "14.1X50-D145"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "14.1X53",
                            "version_value": "14.1X53-D47"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "15.1",
                            "version_value": "15.1R2"
                          },
                          {
                            "platform": "SRX Series",
                            "version_affected": "\u003c",
                            "version_name": "15.1X49",
                            "version_value": "15.1X49-D170"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "15.1X53",
                            "version_value": "15.1X53-D67"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Juniper Networks"
              }
            ]
          }
        },
        "configuration": [
          {
            "lang": "en",
            "value": "This issue affects Junos OS devices with OAM Ethernet configured:\n\n  [protocols oam ethernet connectivity-fault-management]"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "When an attacker sends a specific crafted Ethernet Operation, Administration, and Maintenance (Ethernet OAM) packet to a target device, it may improperly handle the incoming malformed data and fail to sanitize this incoming data resulting in an overflow condition. This overflow condition in Juniper Networks Junos OS allows an attacker to cause a Denial of Service (DoS) condition by coring the CFM daemon. Continued receipt of these packets may cause an extended Denial of Service condition. This issue affects: Juniper Networks Junos OS 12.3 versions prior to 12.3R12-S15; 12.3X48 versions prior to 12.3X48-D95 on SRX Series; 14.1X50 versions prior to 14.1X50-D145; 14.1X53 versions prior to 14.1X53-D47; 15.1 versions prior to 15.1R2; 15.1X49 versions prior to 15.1X49-D170 on SRX Series; 15.1X53 versions prior to 15.1X53-D67."
            }
          ]
        },
        "exploit": [
          {
            "lang": "en",
            "value": "Juniper SIRT is not aware of any malicious exploitation of this vulnerability."
          }
        ],
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-703 Improper Check or Handling of Exceptional Conditions"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.juniper.net/",
              "refsource": "MISC",
              "url": "https://kb.juniper.net/"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "The following software releases have been updated to resolve this specific issue: 12.3R12-S15, 12.3X48-D95, 14.1X50-D145, 14.1X53-D47, 15.1R2, 15.1X49-D170, 16.1R1, and all subsequent releases."
          }
        ],
        "source": {
          "advisory": "JSA11020",
          "defect": [
            "999503"
          ],
          "discovery": "INTERNAL"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "There are no viable workarounds for this issue."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8cbe9d5a-a066-4c94-8978-4b15efeae968",
    "assignerShortName": "juniper",
    "cveId": "CVE-2020-1639",
    "datePublished": "2020-04-08T19:26:02.142Z",
    "dateReserved": "2019-11-04T00:00:00.000Z",
    "dateUpdated": "2024-09-16T22:02:05.337Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-11245 (GCVE-0-2019-11245)

Vulnerability from cvelistv5 – Published: 2019-08-29 00:22 – Updated: 2024-09-16 22:09
VLAI
Title
kubelet-started container uid changes to root after first restart or if image is already pulled to the node
Summary
In kubelet v1.13.6 and v1.14.2, containers for pods that do not specify an explicit runAsUser attempt to run as uid 0 (root) on container restart, or if the image was previously pulled to the node. If the pod specified mustRunAsNonRoot: true, the kubelet will refuse to start the container as root. If the pod did not specify mustRunAsNonRoot: true, the kubelet will run the container as uid 0.
CWE
  • CWE-703 - Improper Check or Handling of Exceptional Conditions
Assigner
References
Impacted products
Vendor Product Version
Kubernetes Kubernetes Affected: v1.13.6
Affected: v1.14.2
Create a notification for this product.
Date Public
2019-05-24 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T22:48:09.001Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://github.com/kubernetes/kubernetes/issues/78308"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20190919-0003/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Kubernetes",
          "vendor": "Kubernetes",
          "versions": [
            {
              "status": "affected",
              "version": "v1.13.6"
            },
            {
              "status": "affected",
              "version": "v1.14.2"
            }
          ]
        }
      ],
      "datePublic": "2019-05-24T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "In kubelet v1.13.6 and v1.14.2, containers for pods that do not specify an explicit runAsUser attempt to run as uid 0 (root) on container restart, or if the image was previously pulled to the node. If the pod specified mustRunAsNonRoot: true, the kubelet will refuse to start the container as root. If the pod did not specify mustRunAsNonRoot: true, the kubelet will run the container as uid 0."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 4.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:L/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-703",
              "description": "CWE-703: Improper Check or Handling of Exceptional Conditions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-09-19T16:06:08.000Z",
        "orgId": "a6081bf6-c852-4425-ad4f-a67919267565",
        "shortName": "kubernetes"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/kubernetes/kubernetes/issues/78308"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20190919-0003/"
        }
      ],
      "source": {
        "defect": [
          "https://github.com/kubernetes/kubernetes/issues/78308"
        ],
        "discovery": "USER"
      },
      "title": "kubelet-started container uid changes to root after first restart or if image is already pulled to the node",
      "workarounds": [
        {
          "lang": "en",
          "value": "Specify runAsUser directives in pods to control the uid a container runs as. Specify mustRunAsNonRoot:true directives in pods to prevent starting as root (note this means the attempt to start the container will fail on affected kubelet versions)."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.7"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "AKA": "",
          "ASSIGNER": "security@kubernetes.io",
          "DATE_PUBLIC": "2019-05-24",
          "ID": "CVE-2019-11245",
          "STATE": "PUBLIC",
          "TITLE": "kubelet-started container uid changes to root after first restart or if image is already pulled to the node"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Kubernetes",
                      "version": {
                        "version_data": [
                          {
                            "platform": "",
                            "version_affected": "=",
                            "version_name": "v1.13",
                            "version_value": "v1.13.6"
                          },
                          {
                            "platform": "",
                            "version_affected": "=",
                            "version_name": "v1.14",
                            "version_value": "v1.14.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Kubernetes"
              }
            ]
          }
        },
        "configuration": [],
        "credit": [],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In kubelet v1.13.6 and v1.14.2, containers for pods that do not specify an explicit runAsUser attempt to run as uid 0 (root) on container restart, or if the image was previously pulled to the node. If the pod specified mustRunAsNonRoot: true, the kubelet will refuse to start the container as root. If the pod did not specify mustRunAsNonRoot: true, the kubelet will run the container as uid 0."
            }
          ]
        },
        "exploit": [],
        "generator": {
          "engine": "Vulnogram 0.0.7"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 4.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:L/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-703: Improper Check or Handling of Exceptional Conditions"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/kubernetes/kubernetes/issues/78308",
              "refsource": "CONFIRM",
              "url": "https://github.com/kubernetes/kubernetes/issues/78308"
            },
            {
              "name": "https://security.netapp.com/advisory/ntap-20190919-0003/",
              "refsource": "CONFIRM",
              "url": "https://security.netapp.com/advisory/ntap-20190919-0003/"
            }
          ]
        },
        "solution": [],
        "source": {
          "advisory": "",
          "defect": [
            "https://github.com/kubernetes/kubernetes/issues/78308"
          ],
          "discovery": "USER"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "Specify runAsUser directives in pods to control the uid a container runs as. Specify mustRunAsNonRoot:true directives in pods to prevent starting as root (note this means the attempt to start the container will fail on affected kubelet versions)."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a6081bf6-c852-4425-ad4f-a67919267565",
    "assignerShortName": "kubernetes",
    "cveId": "CVE-2019-11245",
    "datePublished": "2019-08-29T00:22:24.173Z",
    "dateReserved": "2019-04-17T00:00:00.000Z",
    "dateUpdated": "2024-09-16T22:09:44.877Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-10928 (GCVE-0-2019-10928)

Vulnerability from cvelistv5 – Published: 2019-08-13 18:55 – Updated: 2024-08-04 22:40
VLAI
Summary
A vulnerability has been identified in SCALANCE SC-600 (V2.0). An authenticated attacker with access to port 22/tcp as well as physical access to an affected device may trigger the device to allow execution of arbitrary commands. The security vulnerability could be exploited by an authenticated attacker with physical access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the confidentiality, integrity and availability of the affected device.
Severity
No CVSS data available.
CWE
  • CWE-703 - Improper Check or Handling of Exceptional Conditions
Assigner
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T22:40:15.097Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-671286.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SCALANCE SC-600",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "V2.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SCALANCE SC-600 (V2.0). An authenticated attacker with access to port 22/tcp as well as physical access to an affected device may trigger the device to allow execution of arbitrary commands. The security vulnerability could be exploited by an authenticated attacker with physical access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the confidentiality, integrity and availability of the affected device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-703",
              "description": "CWE-703: Improper Check or Handling of Exceptional Conditions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-07-14T13:18:04.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-671286.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2019-10928",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SCALANCE SC-600",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "V2.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SCALANCE SC-600 (V2.0). An authenticated attacker with access to port 22/tcp as well as physical access to an affected device may trigger the device to allow execution of arbitrary commands. The security vulnerability could be exploited by an authenticated attacker with physical access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the confidentiality, integrity and availability of the affected device."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-703: Improper Check or Handling of Exceptional Conditions"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-671286.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-671286.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-10928",
    "datePublished": "2019-08-13T18:55:57.000Z",
    "dateReserved": "2019-04-08T00:00:00.000Z",
    "dateUpdated": "2024-08-04T22:40:15.097Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-10927 (GCVE-0-2019-10927)

Vulnerability from cvelistv5 – Published: 2019-08-13 18:55 – Updated: 2024-08-04 22:40
VLAI
Summary
A vulnerability has been identified in SCALANCE SC-600 (V2.0), SCALANCE XB-200 (V4.1), SCALANCE XC-200 (V4.1), SCALANCE XF-200BA (V4.1), SCALANCE XP-200 (V4.1), SCALANCE XR-300WG (V4.1). An authenticated attacker with network access to to port 22/tcp of an affected device may cause a Denial-of-Service condition. The security vulnerability could be exploited by an authenticated attacker with network access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the availability of the affected device.
Severity
No CVSS data available.
CWE
  • CWE-703 - Improper Check or Handling of Exceptional Conditions
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T22:40:15.129Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-671286.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SCALANCE SC-600",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "V2.0"
            }
          ]
        },
        {
          "product": "SCALANCE XB-200",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC-200",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XF-200BA",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XP-200",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XR-300WG",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "V4.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SCALANCE SC-600 (V2.0), SCALANCE XB-200 (V4.1), SCALANCE XC-200 (V4.1), SCALANCE XF-200BA (V4.1), SCALANCE XP-200 (V4.1), SCALANCE XR-300WG (V4.1). An authenticated attacker with network access to to port 22/tcp of an affected device may cause a Denial-of-Service condition. The security vulnerability could be exploited by an authenticated attacker with network access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the availability of the affected device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-703",
              "description": "CWE-703: Improper Check or Handling of Exceptional Conditions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-07-14T13:18:04.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-671286.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2019-10927",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SCALANCE SC-600",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "V2.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XB-200",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC-200",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XF-200BA",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XP-200",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR-300WG",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "V4.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SCALANCE SC-600 (V2.0), SCALANCE XB-200 (V4.1), SCALANCE XC-200 (V4.1), SCALANCE XF-200BA (V4.1), SCALANCE XP-200 (V4.1), SCALANCE XR-300WG (V4.1). An authenticated attacker with network access to to port 22/tcp of an affected device may cause a Denial-of-Service condition. The security vulnerability could be exploited by an authenticated attacker with network access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the availability of the affected device."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-703: Improper Check or Handling of Exceptional Conditions"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-671286.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-671286.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-10927",
    "datePublished": "2019-08-13T18:55:57.000Z",
    "dateReserved": "2019-04-08T00:00:00.000Z",
    "dateUpdated": "2024-08-04T22:40:15.129Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-5031 (GCVE-0-2019-5031)

Vulnerability from cvelistv5 – Published: 2019-10-02 15:55 – Updated: 2024-08-04 19:40
VLAI
Summary
An exploitable memory corruption vulnerability exists in the JavaScript engine of Foxit Software's Foxit PDF Reader, version 9.4.1.16828. A specially crafted PDF document can trigger an out-of-memory condition which isn't handled properly, resulting in arbitrary code execution. An attacker needs to trick the user to open the malicious file to trigger this vulnerability. If the browser plugin extension is enabled, visiting a malicious site can also trigger the vulnerability.
CWE
  • CWE-703 - Improper Check or Handling of Exceptional Conditions
Assigner
References
Impacted products
Vendor Product Version
n/a Foxit Affected: Foxit Software Foxit PDF Reader 9.4.1.16828.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T19:40:49.213Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0793"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Foxit",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Foxit Software Foxit PDF Reader 9.4.1.16828."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An exploitable memory corruption vulnerability exists in the JavaScript engine of Foxit Software\u0027s Foxit PDF Reader, version 9.4.1.16828. A specially crafted PDF document can trigger an out-of-memory condition which isn\u0027t handled properly, resulting in arbitrary code execution. An attacker needs to trick the user to open the malicious file to trigger this vulnerability. If the browser plugin extension is enabled, visiting a malicious site can also trigger the vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-703",
              "description": "CWE-703: Improper Check or Handling of Exceptional Conditions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-19T17:33:03.000Z",
        "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
        "shortName": "talos"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0793"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "talos-cna@cisco.com",
          "ID": "CVE-2019-5031",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Foxit",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Foxit Software Foxit PDF Reader 9.4.1.16828."
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An exploitable memory corruption vulnerability exists in the JavaScript engine of Foxit Software\u0027s Foxit PDF Reader, version 9.4.1.16828. A specially crafted PDF document can trigger an out-of-memory condition which isn\u0027t handled properly, resulting in arbitrary code execution. An attacker needs to trick the user to open the malicious file to trigger this vulnerability. If the browser plugin extension is enabled, visiting a malicious site can also trigger the vulnerability."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 8.8,
            "baseSeverity": "High",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-703: Improper Check or Handling of Exceptional Conditions"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0793",
              "refsource": "MISC",
              "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0793"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
    "assignerShortName": "talos",
    "cveId": "CVE-2019-5031",
    "datePublished": "2019-10-02T15:55:15.000Z",
    "dateReserved": "2019-01-04T00:00:00.000Z",
    "dateUpdated": "2024-08-04T19:40:49.213Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-12551 (GCVE-0-2018-12551)

Vulnerability from cvelistv5 – Published: 2019-03-27 17:26 – Updated: 2024-08-05 08:38
VLAI
Summary
When Eclipse Mosquitto version 1.0 to 1.5.5 (inclusive) is configured to use a password file for authentication, any malformed data in the password file will be treated as valid. This typically means that the malformed data becomes a username and no password. If this occurs, clients can circumvent authentication and get access to the broker by using the malformed username. In particular, a blank line will be treated as a valid empty username. Other security measures are unaffected. Users who have only used the mosquitto_passwd utility to create and modify their password files are unaffected by this vulnerability.
Severity
No CVSS data available.
CWE
  • CWE-703 - Improper Check or Handling of Exceptional Conditions
Assigner
References
Impacted products
Vendor Product Version
The Eclipse Foundation Eclipse Mosquitto Affected: 1.0 , < unspecified (custom)
Affected: unspecified , ≤ 1.5.5 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T08:38:06.296Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://bugs.eclipse.org/bugs/show_bug.cgi?id=543401"
          },
          {
            "name": "[debian-lts-announce] 20191026 [SECURITY] [DLA 1972-1] mosquitto security update",
            "tags": [
              "mailing-list",
              "x_refsource_MLIST",
              "x_transferred"
            ],
            "url": "https://lists.debian.org/debian-lts-announce/2019/10/msg00035.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Eclipse Mosquitto",
          "vendor": "The Eclipse Foundation",
          "versions": [
            {
              "lessThan": "unspecified",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "1.5.5",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "When Eclipse Mosquitto version 1.0 to 1.5.5 (inclusive) is configured to use a password file for authentication, any malformed data in the password file will be treated as valid. This typically means that the malformed data becomes a username and no password. If this occurs, clients can circumvent authentication and get access to the broker by using the malformed username. In particular, a blank line will be treated as a valid empty username. Other security measures are unaffected. Users who have only used the mosquitto_passwd utility to create and modify their password files are unaffected by this vulnerability."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-703",
              "description": "CWE-703: Improper Check or Handling of Exceptional Conditions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-10-26T23:06:13.000Z",
        "orgId": "e51fbebd-6053-4e49-959f-1b94eeb69a2c",
        "shortName": "eclipse"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://bugs.eclipse.org/bugs/show_bug.cgi?id=543401"
        },
        {
          "name": "[debian-lts-announce] 20191026 [SECURITY] [DLA 1972-1] mosquitto security update",
          "tags": [
            "mailing-list",
            "x_refsource_MLIST"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2019/10/msg00035.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security@eclipse.org",
          "ID": "CVE-2018-12551",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Eclipse Mosquitto",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003e=",
                            "version_value": "1.0"
                          },
                          {
                            "version_affected": "\u003c=",
                            "version_value": "1.5.5"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "The Eclipse Foundation"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "When Eclipse Mosquitto version 1.0 to 1.5.5 (inclusive) is configured to use a password file for authentication, any malformed data in the password file will be treated as valid. This typically means that the malformed data becomes a username and no password. If this occurs, clients can circumvent authentication and get access to the broker by using the malformed username. In particular, a blank line will be treated as a valid empty username. Other security measures are unaffected. Users who have only used the mosquitto_passwd utility to create and modify their password files are unaffected by this vulnerability."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-703: Improper Check or Handling of Exceptional Conditions"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://bugs.eclipse.org/bugs/show_bug.cgi?id=543401",
              "refsource": "CONFIRM",
              "url": "https://bugs.eclipse.org/bugs/show_bug.cgi?id=543401"
            },
            {
              "name": "[debian-lts-announce] 20191026 [SECURITY] [DLA 1972-1] mosquitto security update",
              "refsource": "MLIST",
              "url": "https://lists.debian.org/debian-lts-announce/2019/10/msg00035.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e51fbebd-6053-4e49-959f-1b94eeb69a2c",
    "assignerShortName": "eclipse",
    "cveId": "CVE-2018-12551",
    "datePublished": "2019-03-27T17:26:20.000Z",
    "dateReserved": "2018-06-18T00:00:00.000Z",
    "dateUpdated": "2024-08-05T08:38:06.296Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-5463 (GCVE-0-2018-5463)

Vulnerability from cvelistv5 – Published: 2018-04-09 21:00 – Updated: 2024-09-16 20:26
VLAI
Summary
A structured exception handler overflow vulnerability in Leao Consultoria e Desenvolvimento de Sistemas (LCDS) LTDA ME LAquis SCADA 4.1.0.3391 and earlier may allow code execution.
Severity
No CVSS data available.
CWE
  • CWE-703 - IMPROPER CHECK OR HANDLING OF EXCEPTIONAL CONDITIONS CWE-703
Assigner
References
Date Public
2018-04-05 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T05:33:44.344Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-095-03"
          },
          {
            "name": "103724",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/103724"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "LCDS - Le\u0026#195;\u0026#163;o Consultoria e Desenvolvimento de Sistemas LTDA ME LAquis SCADA",
          "vendor": "ICS-CERT",
          "versions": [
            {
              "status": "affected",
              "version": "4.1.0.3391 and prior"
            }
          ]
        }
      ],
      "datePublic": "2018-04-05T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A structured exception handler overflow vulnerability in Leao Consultoria e Desenvolvimento de Sistemas (LCDS) LTDA ME LAquis SCADA 4.1.0.3391 and earlier may allow code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-703",
              "description": "IMPROPER CHECK OR HANDLING OF EXCEPTIONAL CONDITIONS CWE-703",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-04-12T09:57:02.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-095-03"
        },
        {
          "name": "103724",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/103724"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-04-05T00:00:00",
          "ID": "CVE-2018-5463",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "LCDS - Le\u0026#195;\u0026#163;o Consultoria e Desenvolvimento de Sistemas LTDA ME LAquis SCADA",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "4.1.0.3391 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ICS-CERT"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A structured exception handler overflow vulnerability in Leao Consultoria e Desenvolvimento de Sistemas (LCDS) LTDA ME LAquis SCADA 4.1.0.3391 and earlier may allow code execution."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "IMPROPER CHECK OR HANDLING OF EXCEPTIONAL CONDITIONS CWE-703"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-095-03",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-095-03"
            },
            {
              "name": "103724",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/103724"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-5463",
    "datePublished": "2018-04-09T21:00:00.000Z",
    "dateReserved": "2018-01-12T00:00:00.000Z",
    "dateUpdated": "2024-09-16T20:26:49.223Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-16014 (GCVE-0-2017-16014)

Vulnerability from cvelistv5 – Published: 2018-06-04 19:00 – Updated: 2024-09-16 21:57
VLAI
Summary
Http-proxy is a proxying library. Because of the way errors are handled in versions before 0.7.0, an attacker that forces an error can crash the server, causing a denial of service.
Severity
No CVSS data available.
CWE
  • CWE-703 - Improper Check or Handling of Exceptional Conditions (CWE-703)
Assigner
References
Impacted products
Date Public
2018-04-26 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T20:13:06.645Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/nodejitsu/node-http-proxy/pull/101"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://nodesecurity.io/advisories/323"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "http-proxy node module",
          "vendor": "HackerOne",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c=0.6.6"
            }
          ]
        }
      ],
      "datePublic": "2018-04-26T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Http-proxy is a proxying library. Because of the way errors are handled in versions before 0.7.0, an attacker that forces an error can crash the server, causing a denial of service."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-703",
              "description": "Improper Check or Handling of Exceptional Conditions (CWE-703)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-06-04T18:57:01.000Z",
        "orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
        "shortName": "hackerone"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/nodejitsu/node-http-proxy/pull/101"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://nodesecurity.io/advisories/323"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "support@hackerone.com",
          "DATE_PUBLIC": "2018-04-26T00:00:00",
          "ID": "CVE-2017-16014",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "http-proxy node module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "\u003c=0.6.6"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "HackerOne"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Http-proxy is a proxying library. Because of the way errors are handled in versions before 0.7.0, an attacker that forces an error can crash the server, causing a denial of service."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Improper Check or Handling of Exceptional Conditions (CWE-703)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/nodejitsu/node-http-proxy/pull/101",
              "refsource": "MISC",
              "url": "https://github.com/nodejitsu/node-http-proxy/pull/101"
            },
            {
              "name": "https://nodesecurity.io/advisories/323",
              "refsource": "MISC",
              "url": "https://nodesecurity.io/advisories/323"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
    "assignerShortName": "hackerone",
    "cveId": "CVE-2017-16014",
    "datePublished": "2018-06-04T19:00:00.000Z",
    "dateReserved": "2017-10-29T00:00:00.000Z",
    "dateUpdated": "2024-09-16T21:57:09.433Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

GHSA-22QQ-3XWM-R5X4

Vulnerability from github – Published: 2025-02-03 15:55 – Updated: 2026-03-09 20:46
VLAI
Summary
CometBFT allows a malicious peer to make node stuck in blocksync
Details

Name: ASA-2025-001: Malicious peer can disrupt node's ability to sync via blocksync Component: CometBFT [OUTDATED] Criticality: Medium (Considerable Impact; Possible Likelihood per ACMv1.2) Update of Criticality on 2026-03-06: We've made a mistake and over-rated the criticality of this bug in our initial triage. We have calibrated our vulnerability rating internally and updated the criticality of this bug to be Informational (Negligible Impact, Possible Likelihood) Affected versions: <= v0.38.16, v1.0.0 Affected users: Validators, Full nodes

Impact

A malicious peer may be able to interfere with a node's ability to sync blocks with peers via the blocksync mechanism.

In the blocksync protocol peers send their base and latest heights when they connect to a new node (A), which is syncing to the tip of a network. base acts as a lower ground and informs A that the peer only has blocks starting from height base. latest height informs A about the latest block in a network. Normally, nodes would only report increasing heights:

B: {base: 100, latest: 1000}
B: {base: 100, latest: 1001}
B: {base: 100, latest: 1002}
...

If B fails to provide the latest block, B is removed and the latest height (target height) is recalculated based on other nodes latest heights.

The existing code hovewer doesn't check for the case where B first reports latest height X and immediately after height Y, where X > Y. For example:

B: {base: 100, latest: 2000}
B: {base: 100, latest: 1001}
B: {base: 100, latest: 1002}
...

A will be trying to catch up to 2000 indefinitely. Even if B disconnects, the latest height (target height) won't be recalculated because A "doesn't know where 2000" came from per see.

Impact Qualification

This condition requires the introduction of malicious code in the full node first reporting a non-existing latest height, then reporting lower latest height and nodes which are syncing using blocksync protocol.

Patches

The new CometBFT releases v1.0.1 and v0.38.17 fix this issue.

Unreleased code in the main is patched as well.

Workarounds

When the operator notices blocksync is stuck, they can identify the peer from which that message with "invalid" height was received. This may require increasing the logging level of the blocksync module. This peer can then be subsequently banned at the p2p layer as a temporary mitigation.

References

If you have questions about Interchain security efforts, please reach out to our official communication channel at security@interchain.io. For more information about the Interchain Foundation’s engagement with Amulet, and to sign up for security notification emails, please see https://github.com/interchainio/security.

A Github Security Advisory for this issue is available in the CometBFT repository. For more information about CometBFT, see https://docs.cometbft.com/.

EDIT:

Please notice that this has been updated to be informational severity. This can be avoided by ensuring that one is not connected to a malicious peer during blocksync.

Show details on source website

{
  "affected": [
    {
      "package": {
        "ecosystem": "Go",
        "name": "github.com/cometbft/cometbft"
      },
      "ranges": [
        {
          "events": [
            {
              "introduced": "1.0.0-alpha.1"
            },
            {
              "fixed": "1.0.1"
            }
          ],
          "type": "ECOSYSTEM"
        }
      ]
    },
    {
      "package": {
        "ecosystem": "Go",
        "name": "github.com/cometbft/cometbft"
      },
      "ranges": [
        {
          "events": [
            {
              "introduced": "0"
            },
            {
              "fixed": "0.38.17"
            }
          ],
          "type": "ECOSYSTEM"
        }
      ]
    }
  ],
  "aliases": [
    "CVE-2025-24371"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-703"
    ],
    "github_reviewed": true,
    "github_reviewed_at": "2025-02-03T15:55:28Z",
    "nvd_published_at": "2025-02-03T22:15:28Z",
    "severity": "MODERATE"
  },
  "details": "Name: ASA-2025-001: Malicious peer can disrupt node\u0027s ability to sync via blocksync\nComponent: CometBFT\n[OUTDATED] Criticality: Medium (Considerable Impact; Possible Likelihood per [ACMv1.2](https://github.com/interchainio/security/blob/main/resources/CLASSIFICATION_MATRIX.md))\n**Update of Criticality on 2026-03-06**: We\u0027ve made a mistake and over-rated the criticality of this bug in our initial triage. We have calibrated our vulnerability rating internally and updated the criticality of this bug to be Informational (Negligible Impact, Possible Likelihood)\nAffected versions: \u003c= v0.38.16, v1.0.0\nAffected users: Validators, Full nodes\n\n### Impact\n\nA malicious peer may be able to interfere with a node\u0027s ability to sync blocks with peers via the blocksync mechanism. \n\nIn the `blocksync` protocol peers send their `base` and `latest` heights when they connect to a new node (`A`), which is syncing to the tip of a network. `base` acts as a lower ground and informs `A` that the peer only has blocks starting from height `base`. `latest` height informs `A` about the latest block in a network. Normally, nodes would only report increasing heights:\n\n```\nB: {base: 100, latest: 1000}\nB: {base: 100, latest: 1001}\nB: {base: 100, latest: 1002}\n...\n```\n\nIf `B` fails to provide the latest block, `B` is removed and the `latest` height (target height) is recalculated based on other nodes `latest` heights.\n\nThe existing code hovewer doesn\u0027t check for the case where `B` first reports `latest` height `X` and immediately after height `Y`, where `X \u003e Y`. For example:\n\n```\nB: {base: 100, latest: 2000}\nB: {base: 100, latest: 1001}\nB: {base: 100, latest: 1002}\n...\n```\n\n`A` will be trying to catch up to 2000 indefinitely. Even if `B` disconnects, the `latest` height (target height) won\u0027t be recalculated because `A` \"doesn\u0027t know where 2000\" came from per see.\n\n#### Impact Qualification\n\nThis condition requires the introduction of malicious code in the full node first reporting a non-existing `latest` height, then reporting lower `latest` height and nodes which are syncing using `blocksync` protocol.\n\n### Patches\n\nThe new CometBFT releases [v1.0.1](https://github.com/cometbft/cometbft/releases/tag/v1.0.1) and [v0.38.17](https://github.com/cometbft/cometbft/releases/tag/v0.38.17) fix this issue.\n\nUnreleased code in the main is patched as well.\n\n### Workarounds\n\nWhen the operator notices `blocksync` is stuck, they can identify the peer from which that message with \"invalid\" height was received. This may require increasing the logging level of the `blocksync` module. This peer can then be subsequently banned at the p2p layer as a temporary mitigation.\n\n### References\n\nIf you have questions about Interchain security efforts, please reach out to our official communication channel at [security@interchain.io](mailto:security@interchain.io).  For more information about the Interchain Foundation\u2019s engagement with Amulet, and to sign up for security notification emails, please see https://github.com/interchainio/security.  \n\nA Github Security Advisory for this issue is available in the CometBFT [repository](https://github.com/cometbft/cometbft/security/advisories/GHSA-22qq-3xwm-r5x4). For more information about CometBFT, see https://docs.cometbft.com/.\n\nEDIT:\n\nPlease notice that this has been updated to be `informational` severity.  This can be avoided by ensuring that one is not connected to a malicious peer during blocksync.",
  "id": "GHSA-22qq-3xwm-r5x4",
  "modified": "2026-03-09T20:46:44Z",
  "published": "2025-02-03T15:55:28Z",
  "references": [
    {
      "type": "WEB",
      "url": "https://github.com/cometbft/cometbft/security/advisories/GHSA-22qq-3xwm-r5x4"
    },
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2025-24371"
    },
    {
      "type": "WEB",
      "url": "https://github.com/cometbft/cometbft/commit/0ee80cd609c7ae9fe856bdd1c6d38553fdae90ce"
    },
    {
      "type": "WEB",
      "url": "https://github.com/cometbft/cometbft/commit/2cebfde06ae5073c0b296a9d2ca6ab4b95397ea5"
    },
    {
      "type": "PACKAGE",
      "url": "https://github.com/cometbft/cometbft"
    },
    {
      "type": "WEB",
      "url": "https://github.com/cometbft/cometbft/releases/tag/v0.38.17"
    },
    {
      "type": "WEB",
      "url": "https://github.com/cometbft/cometbft/releases/tag/v1.0.1"
    },
    {
      "type": "WEB",
      "url": "https://pkg.go.dev/vuln/GO-2025-3442"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
      "type": "CVSS_V4"
    }
  ],
  "summary": "CometBFT allows a malicious peer to make node stuck in blocksync"
}

GHSA-27JF-22P2-6VQ4

Vulnerability from github – Published: 2023-08-29 09:30 – Updated: 2024-04-04 07:15
VLAI
Details

Motorola EBTS/MBTS Site Controller drops to debug prompt on unhandled exception. The Motorola MBTS Site Controller exposes a debug prompt on the device's serial port in case of an unhandled exception. This allows an attacker with physical access that is able to trigger such an exception to extract secret key material and/or gain arbitrary code execution on the device.

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2023-23774"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-248",
      "CWE-703",
      "CWE-755"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2023-08-29T09:15:09Z",
    "severity": "HIGH"
  },
  "details": "Motorola EBTS/MBTS Site Controller drops to debug prompt on unhandled exception. The Motorola MBTS Site Controller exposes a debug prompt on the device\u0027s serial port in case of an unhandled exception. This allows an attacker with physical access that is able to trigger such an exception to extract secret key material and/or gain arbitrary code execution on the device.",
  "id": "GHSA-27jf-22p2-6vq4",
  "modified": "2024-04-04T07:15:16Z",
  "published": "2023-08-29T09:30:24Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2023-23774"
    },
    {
      "type": "WEB",
      "url": "https://tetraburst.com"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
      "type": "CVSS_V3"
    }
  ]
}

No mitigation information available for this CWE.

No CAPEC attack patterns related to this CWE.