Common Weakness Enumeration
CWE-248
AllowedUncaught Exception
Abstraction: Base · Status: Draft
An exception is thrown from a function, but it is not caught.
420 vulnerabilities reference this CWE, most recent first.
CVE-2020-10292 (GCVE-0-2020-10292)
Vulnerability from cvelistv5 – Published: 2020-11-06 11:20 – Updated: 2024-09-17 04:29
VLAI
EPSS
VEX
Title
Service DoS through arbitrary pointer dereferencing on KUKA simulator
Summary
Visual Components (owned by KUKA) is a robotic simulator that allows simulating factories and robots in order toimprove planning and decision-making processes. Visual Components software requires a special license which can beobtained from a network license server. The network license server binds to all interfaces (0.0.0.0) and listensfor packets over UDP port 5093. No authentication/authorization is required in order to communicate with theserver. The protocol being used is a property protocol by RMS Sentinel which provides the licensing infrastructurefor the network license server. RMS Sentinel license manager service exposes UDP port 5093 which provides sensitivesystem information that could be leveraged for further exploitation without any kind of authentication. Thisinformation includes detailed hardware and OS characteristics.After a decryption process, a textual protocol is found which contains a simple header with the requested command,application-identifier, and some arguments. The protocol is vulnerable to DoS through an arbitrary pointerderreference. This flaw allows an attacker to to pass a specially crafted package that, when processed by theservice, causes an arbitrary pointer from the stack to be dereferenced, causing an uncaught exception thatterminates the service. This can be further contructed in combination with RVDP#710 which exploits an informationdisclosure leak, or with RVDP#711 for an stack-overflow and potential code execution.Beyond denying simulations, Visual Components provides capabilities to interface with industrial machinery andautomate certain processes (e.g. testing, benchmarking, etc.) which depending on the DevOps setup might beintegrated into the industrial flow. Accordingly, a DoS in the simulation might have higher repercusions, dependingon the Industrial Control System (ICS) ICS infrastructure.
Severity
8.2 (High)
CWE
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.visualcomponents.com/products/visual-… | x_refsource_CONFIRM |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| KUKA Roboter GmbH | Visual Components Network License Server 2.0.8 |
Affected:
unspecified
|
Date Public
2020-11-06 00:00
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T10:58:40.018Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.visualcomponents.com/products/visual-components/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Visual Components Network License Server 2.0.8",
"vendor": "KUKA Roboter GmbH",
"versions": [
{
"status": "affected",
"version": "unspecified"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Sharon Brizinov (Claroty)"
}
],
"datePublic": "2020-11-06T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Visual Components (owned by KUKA) is a robotic simulator that allows simulating factories and robots in order toimprove planning and decision-making processes. Visual Components software requires a special license which can beobtained from a network license server. The network license server binds to all interfaces (0.0.0.0) and listensfor packets over UDP port 5093. No authentication/authorization is required in order to communicate with theserver. The protocol being used is a property protocol by RMS Sentinel which provides the licensing infrastructurefor the network license server. RMS Sentinel license manager service exposes UDP port 5093 which provides sensitivesystem information that could be leveraged for further exploitation without any kind of authentication. Thisinformation includes detailed hardware and OS characteristics.After a decryption process, a textual protocol is found which contains a simple header with the requested command,application-identifier, and some arguments. The protocol is vulnerable to DoS through an arbitrary pointerderreference. This flaw allows an attacker to to pass a specially crafted package that, when processed by theservice, causes an arbitrary pointer from the stack to be dereferenced, causing an uncaught exception thatterminates the service. This can be further contructed in combination with RVDP#710 which exploits an informationdisclosure leak, or with RVDP#711 for an stack-overflow and potential code execution.Beyond denying simulations, Visual Components provides capabilities to interface with industrial machinery andautomate certain processes (e.g. testing, benchmarking, etc.) which depending on the DevOps setup might beintegrated into the industrial flow. Accordingly, a DoS in the simulation might have higher repercusions, dependingon the Industrial Control System (ICS) ICS infrastructure."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-248",
"description": "CWE-248",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-06T11:20:12.000Z",
"orgId": "dc524f69-879d-41dc-ab8f-724e78658a1a",
"shortName": "Alias"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.visualcomponents.com/products/visual-components/"
}
],
"source": {
"defect": [
"RVD#712"
],
"discovery": "EXTERNAL"
},
"title": "Service DoS through arbitrary pointer dereferencing on KUKA simulator",
"x_generator": {
"engine": "Robot Vulnerability Database (RVD)"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@aliasrobotics.com",
"DATE_PUBLIC": "2020-11-06T11:14:41 +00:00",
"ID": "CVE-2020-10292",
"STATE": "PUBLIC",
"TITLE": "Service DoS through arbitrary pointer dereferencing on KUKA simulator"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Visual Components Network License Server 2.0.8",
"version": {
"version_data": [
{
"version_value": ""
}
]
}
}
]
},
"vendor_name": "KUKA Roboter GmbH"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Sharon Brizinov (Claroty)"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Visual Components (owned by KUKA) is a robotic simulator that allows simulating factories and robots in order toimprove planning and decision-making processes. Visual Components software requires a special license which can beobtained from a network license server. The network license server binds to all interfaces (0.0.0.0) and listensfor packets over UDP port 5093. No authentication/authorization is required in order to communicate with theserver. The protocol being used is a property protocol by RMS Sentinel which provides the licensing infrastructurefor the network license server. RMS Sentinel license manager service exposes UDP port 5093 which provides sensitivesystem information that could be leveraged for further exploitation without any kind of authentication. Thisinformation includes detailed hardware and OS characteristics.After a decryption process, a textual protocol is found which contains a simple header with the requested command,application-identifier, and some arguments. The protocol is vulnerable to DoS through an arbitrary pointerderreference. This flaw allows an attacker to to pass a specially crafted package that, when processed by theservice, causes an arbitrary pointer from the stack to be dereferenced, causing an uncaught exception thatterminates the service. This can be further contructed in combination with RVDP#710 which exploits an informationdisclosure leak, or with RVDP#711 for an stack-overflow and potential code execution.Beyond denying simulations, Visual Components provides capabilities to interface with industrial machinery andautomate certain processes (e.g. testing, benchmarking, etc.) which depending on the DevOps setup might beintegrated into the industrial flow. Accordingly, a DoS in the simulation might have higher repercusions, dependingon the Industrial Control System (ICS) ICS infrastructure."
}
]
},
"generator": {
"engine": "Robot Vulnerability Database (RVD)"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "high",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-248"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.visualcomponents.com/products/visual-components/",
"refsource": "CONFIRM",
"url": "https://www.visualcomponents.com/products/visual-components/"
}
]
},
"source": {
"defect": [
"RVD#712"
],
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "dc524f69-879d-41dc-ab8f-724e78658a1a",
"assignerShortName": "Alias",
"cveId": "CVE-2020-10292",
"datePublished": "2020-11-06T11:20:12.790Z",
"dateReserved": "2020-03-10T00:00:00.000Z",
"dateUpdated": "2024-09-17T04:29:05.653Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-6019 (GCVE-0-2020-6019)
Vulnerability from cvelistv5 – Published: 2020-11-13 15:03 – Updated: 2024-08-04 08:47
VLAI
EPSS
VEX
Summary
Valve's Game Networking Sockets prior to version v1.2.0 improperly handles inlined statistics messages in function CConnectionTransportUDPBase::Received_Data(), leading to an exception thrown from libprotobuf and resulting in a crash.
Severity
No CVSS data available.
CWE
- CWE-248 - Uncaught Exception
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://github.com/ValveSoftware/GameNetworkingSo… | x_refsource_MISC |
| https://research.checkpoint.com/2020/game-on-find… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Game Networking Sockets |
Affected:
All versions prior to v1.2.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T08:47:41.004Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/ValveSoftware/GameNetworkingSockets/commit/d944a10808891d202bb1d5e1998de6e0423af678"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://research.checkpoint.com/2020/game-on-finding-vulnerabilities-in-valves-steam-sockets/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Game Networking Sockets",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "All versions prior to v1.2.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Valve\u0027s Game Networking Sockets prior to version v1.2.0 improperly handles inlined statistics messages in function CConnectionTransportUDPBase::Received_Data(), leading to an exception thrown from libprotobuf and resulting in a crash."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-248",
"description": "CWE-248: Uncaught Exception",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-10T17:45:22.000Z",
"orgId": "897c38be-0345-43cd-b6cf-fe179e0c4f45",
"shortName": "checkpoint"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/ValveSoftware/GameNetworkingSockets/commit/d944a10808891d202bb1d5e1998de6e0423af678"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://research.checkpoint.com/2020/game-on-finding-vulnerabilities-in-valves-steam-sockets/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@checkpoint.com",
"ID": "CVE-2020-6019",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Game Networking Sockets",
"version": {
"version_data": [
{
"version_value": "All versions prior to v1.2.0"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Valve\u0027s Game Networking Sockets prior to version v1.2.0 improperly handles inlined statistics messages in function CConnectionTransportUDPBase::Received_Data(), leading to an exception thrown from libprotobuf and resulting in a crash."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-248: Uncaught Exception"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://github.com/ValveSoftware/GameNetworkingSockets/commit/d944a10808891d202bb1d5e1998de6e0423af678",
"refsource": "MISC",
"url": "https://github.com/ValveSoftware/GameNetworkingSockets/commit/d944a10808891d202bb1d5e1998de6e0423af678"
},
{
"name": "https://research.checkpoint.com/2020/game-on-finding-vulnerabilities-in-valves-steam-sockets/",
"refsource": "MISC",
"url": "https://research.checkpoint.com/2020/game-on-finding-vulnerabilities-in-valves-steam-sockets/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "897c38be-0345-43cd-b6cf-fe179e0c4f45",
"assignerShortName": "checkpoint",
"cveId": "CVE-2020-6019",
"datePublished": "2020-11-13T15:03:31.000Z",
"dateReserved": "2020-01-07T00:00:00.000Z",
"dateUpdated": "2024-08-04T08:47:41.004Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-5129 (GCVE-0-2020-5129)
Vulnerability from cvelistv5 – Published: 2020-03-26 03:35 – Updated: 2024-08-04 08:22
VLAI
EPSS
VEX
Summary
A vulnerability in the SonicWall SMA1000 HTTP Extraweb server allows an unauthenticated remote attacker to cause HTTP server crash which leads to Denial of Service. This vulnerability affected SMA1000 Version 12.1.0-06411 and earlier.
Severity
No CVSS data available.
CWE
- CWE-248 - Uncaught Exception
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://psirt.global.sonicwall.com/vuln-detail/SN… | x_refsource_CONFIRM |
Impacted products
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T08:22:08.523Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2020-0002"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SMA1000",
"vendor": "SonicWall",
"versions": [
{
"status": "affected",
"version": "12.1.0-06411 and earlier"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in the SonicWall SMA1000 HTTP Extraweb server allows an unauthenticated remote attacker to cause HTTP server crash which leads to Denial of Service. This vulnerability affected SMA1000 Version 12.1.0-06411 and earlier."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-248",
"description": "CWE-248: Uncaught Exception",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-03-26T03:35:12.000Z",
"orgId": "44b2ff79-1416-4492-88bb-ed0da00c7315",
"shortName": "sonicwall"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2020-0002"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "PSIRT@sonicwall.com",
"ID": "CVE-2020-5129",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SMA1000",
"version": {
"version_data": [
{
"version_value": "12.1.0-06411 and earlier"
}
]
}
}
]
},
"vendor_name": "SonicWall"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability in the SonicWall SMA1000 HTTP Extraweb server allows an unauthenticated remote attacker to cause HTTP server crash which leads to Denial of Service. This vulnerability affected SMA1000 Version 12.1.0-06411 and earlier."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-248: Uncaught Exception"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2020-0002",
"refsource": "CONFIRM",
"url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2020-0002"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "44b2ff79-1416-4492-88bb-ed0da00c7315",
"assignerShortName": "sonicwall",
"cveId": "CVE-2020-5129",
"datePublished": "2020-03-26T03:35:12.000Z",
"dateReserved": "2019-12-31T00:00:00.000Z",
"dateUpdated": "2024-08-04T08:22:08.523Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-10931 (GCVE-0-2019-10931)
Vulnerability from cvelistv5 – Published: 2019-07-11 21:17 – Updated: 2024-08-04 22:40
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions ), DIGSI 5 engineering software (All versions < V7.90), SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.90), SIPROTEC 5 device types 7SS85 and 7KE85 (All versions < V8.01), SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.59), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.59). Specially crafted packets sent to port 443/TCP could cause a Denial of Service condition.
Severity
No CVSS data available.
CWE
- CWE-248 - Uncaught Exception
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
Impacted products
6 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens AG | All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules |
Affected:
All versions
|
|
| Siemens AG | DIGSI 5 engineering software |
Affected:
All versions < V7.90
|
|
| Siemens AG | SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules |
Affected:
All versions < V7.90
|
|
| Siemens AG | SIPROTEC 5 device types 7SS85 and 7KE85 |
Affected:
All versions < V8.01
|
|
| Siemens AG | SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules |
Affected:
All versions < V7.59
|
|
| Siemens AG | SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules |
Affected:
All versions < V7.59
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T22:40:15.283Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-899560.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "DIGSI 5 engineering software",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.90"
}
]
},
{
"product": "SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.90"
}
]
},
{
"product": "SIPROTEC 5 device types 7SS85 and 7KE85",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V8.01"
}
]
},
{
"product": "SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.59"
}
]
},
{
"product": "SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.59"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions ), DIGSI 5 engineering software (All versions \u003c V7.90), SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions \u003c V7.90), SIPROTEC 5 device types 7SS85 and 7KE85 (All versions \u003c V8.01), SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules (All versions \u003c V7.59), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions \u003c V7.59). Specially crafted packets sent to port 443/TCP could cause a Denial of Service condition."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-248",
"description": "CWE-248: Uncaught Exception",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-10T16:15:57.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-899560.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-10931",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "DIGSI 5 engineering software",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V7.90"
}
]
}
},
{
"product_name": "SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V7.90"
}
]
}
},
{
"product_name": "SIPROTEC 5 device types 7SS85 and 7KE85",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V8.01"
}
]
}
},
{
"product_name": "SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V7.59"
}
]
}
},
{
"product_name": "SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V7.59"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions ), DIGSI 5 engineering software (All versions \u003c V7.90), SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions \u003c V7.90), SIPROTEC 5 device types 7SS85 and 7KE85 (All versions \u003c V8.01), SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules (All versions \u003c V7.59), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions \u003c V7.59). Specially crafted packets sent to port 443/TCP could cause a Denial of Service condition."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-248: Uncaught Exception"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-899560.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-899560.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-10931",
"datePublished": "2019-07-11T21:17:47.000Z",
"dateReserved": "2019-04-08T00:00:00.000Z",
"dateUpdated": "2024-08-04T22:40:15.283Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-10917 (GCVE-0-2019-10917)
Vulnerability from cvelistv5 – Published: 2019-05-14 19:54 – Updated: 2024-08-04 22:40
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An attacker with local access to the project file could cause a Denial-of-Service condition on the affected product while the project file is loaded. Successful exploitation requires access to the project file. An attacker could use the vulnerability to compromise availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
Severity
No CVSS data available.
CWE
- CWE-248 - Uncaught Exception
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://www.us-cert.gov/ics/advisories/ICSA-19-134-08 | x_refsource_MISC |
Impacted products
14 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens AG | SIMATIC PCS 7 V8.0 and earlier |
Affected:
All versions
|
|
| Siemens AG | SIMATIC PCS 7 V8.1 |
Affected:
All versions < V8.1 with WinCC V7.3 Upd 19
|
|
| Siemens AG | SIMATIC PCS 7 V8.2 |
Affected:
All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11
|
|
| Siemens AG | SIMATIC PCS 7 V9.0 |
Affected:
All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11
|
|
| Siemens AG | SIMATIC WinCC (TIA Portal) V13 |
Affected:
All versions
|
|
| Siemens AG | SIMATIC WinCC (TIA Portal) V14 |
Affected:
All versions < V14 SP1 Upd 9
|
|
| Siemens AG | SIMATIC WinCC (TIA Portal) V15 |
Affected:
All versions < V15.1 Upd 3
|
|
| Siemens AG | SIMATIC WinCC Runtime Professional V13 |
Affected:
All versions
|
|
| Siemens AG | SIMATIC WinCC Runtime Professional V14 |
Affected:
All versions < V14.1 Upd 8
|
|
| Siemens AG | SIMATIC WinCC Runtime Professional V15 |
Affected:
All versions < V15.1 Upd 3
|
|
| Siemens AG | SIMATIC WinCC V7.2 and earlier |
Affected:
All versions
|
|
| Siemens AG | SIMATIC WinCC V7.3 |
Affected:
All versions < V7.3 Upd 19
|
|
| Siemens AG | SIMATIC WinCC V7.4 |
Affected:
All versions < V7.4 SP1 Upd 11
|
|
| Siemens AG | SIMATIC WinCC V7.5 |
Affected:
All versions < V7.5 Upd 3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T22:40:15.224Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC PCS 7 V8.0 and earlier",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC PCS 7 V8.1",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V8.1 with WinCC V7.3 Upd 19"
}
]
},
{
"product": "SIMATIC PCS 7 V8.2",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11"
}
]
},
{
"product": "SIMATIC PCS 7 V9.0",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11"
}
]
},
{
"product": "SIMATIC WinCC (TIA Portal) V13",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC WinCC (TIA Portal) V14",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1 Upd 9"
}
]
},
{
"product": "SIMATIC WinCC (TIA Portal) V15",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Upd 3"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional V13",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional V14",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1 Upd 8"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional V15",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Upd 3"
}
]
},
{
"product": "SIMATIC WinCC V7.2 and earlier",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC WinCC V7.3",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.3 Upd 19"
}
]
},
{
"product": "SIMATIC WinCC V7.4",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.4 SP1 Upd 11"
}
]
},
{
"product": "SIMATIC WinCC V7.5",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.5 Upd 3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003c V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). An attacker with local access to the project file could cause a Denial-of-Service condition on the affected product while the project file is loaded. Successful exploitation requires access to the project file. An attacker could use the vulnerability to compromise availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-248",
"description": "CWE-248: Uncaught Exception",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-10-23T19:28:02.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-10917",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC PCS 7 V8.0 and earlier",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC PCS 7 V8.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V8.1 with WinCC V7.3 Upd 19"
}
]
}
},
{
"product_name": "SIMATIC PCS 7 V8.2",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11"
}
]
}
},
{
"product_name": "SIMATIC PCS 7 V9.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11"
}
]
}
},
{
"product_name": "SIMATIC WinCC (TIA Portal) V13",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC WinCC (TIA Portal) V14",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V14 SP1 Upd 9"
}
]
}
},
{
"product_name": "SIMATIC WinCC (TIA Portal) V15",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Upd 3"
}
]
}
},
{
"product_name": "SIMATIC WinCC Runtime Professional V13",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC WinCC Runtime Professional V14",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V14.1 Upd 8"
}
]
}
},
{
"product_name": "SIMATIC WinCC Runtime Professional V15",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Upd 3"
}
]
}
},
{
"product_name": "SIMATIC WinCC V7.2 and earlier",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC WinCC V7.3",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V7.3 Upd 19"
}
]
}
},
{
"product_name": "SIMATIC WinCC V7.4",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V7.4 SP1 Upd 11"
}
]
}
},
{
"product_name": "SIMATIC WinCC V7.5",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V7.5 Upd 3"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003c V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). An attacker with local access to the project file could cause a Denial-of-Service condition on the affected product while the project file is loaded. Successful exploitation requires access to the project file. An attacker could use the vulnerability to compromise availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-248: Uncaught Exception"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-10917",
"datePublished": "2019-05-14T19:54:48.000Z",
"dateReserved": "2019-04-08T00:00:00.000Z",
"dateUpdated": "2024-08-04T22:40:15.224Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-7474 (GCVE-0-2019-7474)
Vulnerability from cvelistv5 – Published: 2019-04-02 17:20 – Updated: 2024-08-04 20:46
VLAI
EPSS
VEX
Summary
A vulnerability in SonicWall SonicOS and SonicOSv, allow authenticated read-only admin to leave the firewall in an unstable state by downloading certificate with specific extension. This vulnerability affected SonicOS Gen 5 version 5.9.1.10 and earlier, Gen 6 version 6.2.7.3, 6.5.1.3, 6.5.2.2, 6.5.3.1, 6.2.7.8, 6.4.0.0, 6.5.1.8, 6.0.5.3-86o and SonicOSv 6.5.0.2-8v_RC363 (VMWARE), 6.5.0.2.8v_RC367 (AZURE), SonicOSv 6.5.0.2.8v_RC368 (AWS), SonicOSv 6.5.0.2.8v_RC366 (HYPER_V).
Severity
No CVSS data available.
CWE
- CWE-248 - Uncaught Exception
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://psirt.global.sonicwall.com/vuln-detail/SN… | x_refsource_CONFIRM |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| SonicWall | SonicOS |
Affected:
5.9.1.10 and earlier
Affected: 6.2.7.3 Affected: 6.5.1.3 Affected: 6.5.2.2 Affected: 6.5.3.1 Affected: 6.2.7.8 Affected: 6.4.0.0 Affected: 6.5.1.8 Affected: 6.0.5.3-86o |
|
| SonicWall | SonicOSv |
Affected:
6.5.0.2-8v_RC363 (VMWARE)
Affected: 6.5.0.2.8v_RC367 (AZURE) Affected: 6.5.0.2.8v_RC368 (AWS) Affected: 6.5.0.2.8v_RC366 (HYPER_V) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:46:46.349Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2019-0001"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SonicOS",
"vendor": "SonicWall",
"versions": [
{
"status": "affected",
"version": "5.9.1.10 and earlier"
},
{
"status": "affected",
"version": "6.2.7.3"
},
{
"status": "affected",
"version": "6.5.1.3"
},
{
"status": "affected",
"version": "6.5.2.2"
},
{
"status": "affected",
"version": "6.5.3.1"
},
{
"status": "affected",
"version": "6.2.7.8"
},
{
"status": "affected",
"version": "6.4.0.0"
},
{
"status": "affected",
"version": "6.5.1.8"
},
{
"status": "affected",
"version": "6.0.5.3-86o"
}
]
},
{
"product": "SonicOSv",
"vendor": "SonicWall",
"versions": [
{
"status": "affected",
"version": "6.5.0.2-8v_RC363 (VMWARE)"
},
{
"status": "affected",
"version": "6.5.0.2.8v_RC367 (AZURE)"
},
{
"status": "affected",
"version": "6.5.0.2.8v_RC368 (AWS)"
},
{
"status": "affected",
"version": "6.5.0.2.8v_RC366 (HYPER_V)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in SonicWall SonicOS and SonicOSv, allow authenticated read-only admin to leave the firewall in an unstable state by downloading certificate with specific extension. This vulnerability affected SonicOS Gen 5 version 5.9.1.10 and earlier, Gen 6 version 6.2.7.3, 6.5.1.3, 6.5.2.2, 6.5.3.1, 6.2.7.8, 6.4.0.0, 6.5.1.8, 6.0.5.3-86o and SonicOSv 6.5.0.2-8v_RC363 (VMWARE), 6.5.0.2.8v_RC367 (AZURE), SonicOSv 6.5.0.2.8v_RC368 (AWS), SonicOSv 6.5.0.2.8v_RC366 (HYPER_V)."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-248",
"description": "CWE-248: Uncaught Exception",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-04-02T17:20:39.000Z",
"orgId": "44b2ff79-1416-4492-88bb-ed0da00c7315",
"shortName": "sonicwall"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2019-0001"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "PSIRT@sonicwall.com",
"ID": "CVE-2019-7474",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SonicOS",
"version": {
"version_data": [
{
"version_value": "5.9.1.10 and earlier"
},
{
"version_value": "6.2.7.3"
},
{
"version_value": "6.5.1.3"
},
{
"version_value": "6.5.2.2"
},
{
"version_value": "6.5.3.1"
},
{
"version_value": "6.2.7.8"
},
{
"version_value": "6.4.0.0"
},
{
"version_value": "6.5.1.8"
},
{
"version_value": "6.0.5.3-86o"
}
]
}
},
{
"product_name": "SonicOSv",
"version": {
"version_data": [
{
"version_value": "6.5.0.2-8v_RC363 (VMWARE)"
},
{
"version_value": "6.5.0.2.8v_RC367 (AZURE)"
},
{
"version_value": "6.5.0.2.8v_RC368 (AWS)"
},
{
"version_value": "6.5.0.2.8v_RC366 (HYPER_V)"
}
]
}
}
]
},
"vendor_name": "SonicWall"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability in SonicWall SonicOS and SonicOSv, allow authenticated read-only admin to leave the firewall in an unstable state by downloading certificate with specific extension. This vulnerability affected SonicOS Gen 5 version 5.9.1.10 and earlier, Gen 6 version 6.2.7.3, 6.5.1.3, 6.5.2.2, 6.5.3.1, 6.2.7.8, 6.4.0.0, 6.5.1.8, 6.0.5.3-86o and SonicOSv 6.5.0.2-8v_RC363 (VMWARE), 6.5.0.2.8v_RC367 (AZURE), SonicOSv 6.5.0.2.8v_RC368 (AWS), SonicOSv 6.5.0.2.8v_RC366 (HYPER_V)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-248: Uncaught Exception"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2019-0001",
"refsource": "CONFIRM",
"url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2019-0001"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "44b2ff79-1416-4492-88bb-ed0da00c7315",
"assignerShortName": "sonicwall",
"cveId": "CVE-2019-7474",
"datePublished": "2019-04-02T17:20:39.000Z",
"dateReserved": "2019-02-06T00:00:00.000Z",
"dateUpdated": "2024-08-04T20:46:46.349Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6830 (GCVE-0-2019-6830)
Vulnerability from cvelistv5 – Published: 2019-09-17 19:21 – Updated: 2024-08-04 20:31
VLAI
EPSS
VEX
Summary
A CWE-248: Uncaught Exception vulnerability exists IN Modicon M580 all versions prior to V2.80, which could cause a possible denial of service when sending an appropriately timed HTTP request to the controller.
Severity
No CVSS data available.
CWE
- CWE-248 - Uncaught Exception
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.schneider-electric.com/en/download/do… | x_refsource_CONFIRM |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | Modicon M580 |
Affected:
all versions prior to V2.80
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.286Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "all versions prior to V2.80"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-248: Uncaught Exception vulnerability exists IN Modicon M580 all versions prior to V2.80, which could cause a possible denial of service when sending an appropriately timed HTTP request to the controller."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-248",
"description": "CWE-248: Uncaught Exception",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-09-17T19:21:12.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2019-6830",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580",
"version": {
"version_data": [
{
"version_value": "all versions prior to V2.80"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-248: Uncaught Exception vulnerability exists IN Modicon M580 all versions prior to V2.80, which could cause a possible denial of service when sending an appropriately timed HTTP request to the controller."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-248: Uncaught Exception"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2019-6830",
"datePublished": "2019-09-17T19:21:12.000Z",
"dateReserved": "2019-01-25T00:00:00.000Z",
"dateUpdated": "2024-08-04T20:31:04.286Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6829 (GCVE-0-2019-6829)
Vulnerability from cvelistv5 – Published: 2019-09-17 19:44 – Updated: 2026-05-29 14:35
VLAI
EPSS
VEX
Summary
A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware version prior to V2.90) and Modicon M340 (firmware version prior to V3.10), which could cause a possible denial of service when writing to specific memory addresses in the controller over Modbus.
Severity
7.5 (High)
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-248 - A CWE-248: Uncaught Exception
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.schneider-electric.com/en/download/do… | x_refsource_CONFIRM |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | Modicon M580 |
Affected:
firmware version prior to V2.90
|
|
| Schneider Electric SE | Modicon M340 |
Affected:
firmware version prior to V3.10
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.339Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2019-6829",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T14:34:30.342289Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-29T14:35:20.646Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "firmware version prior to V2.90"
}
]
},
{
"product": "Modicon M340",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "firmware version prior to V3.10"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware version prior to V2.90) and Modicon M340 (firmware version prior to V3.10), which could cause a possible denial of service when writing to specific memory addresses in the controller over Modbus."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-248",
"description": "A CWE-248: Uncaught Exception",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-09-17T19:44:12.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2019-6829",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580",
"version": {
"version_data": [
{
"version_value": "firmware version prior to V2.90"
}
]
}
},
{
"product_name": "Modicon M340",
"version": {
"version_data": [
{
"version_value": "firmware version prior to V3.10"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware version prior to V2.90) and Modicon M340 (firmware version prior to V3.10), which could cause a possible denial of service when writing to specific memory addresses in the controller over Modbus."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "A CWE-248: Uncaught Exception"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2019-6829",
"datePublished": "2019-09-17T19:44:12.000Z",
"dateReserved": "2019-01-25T00:00:00.000Z",
"dateUpdated": "2026-05-29T14:35:20.646Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2019-6828 (GCVE-0-2019-6828)
Vulnerability from cvelistv5 – Published: 2019-09-17 19:59 – Updated: 2024-08-04 20:31
VLAI
EPSS
VEX
Summary
A CWE-248: Uncaught Exception vulnerability exists Modicon M580 (firmware version prior to V2.90), Modicon M340 (firmware version prior to V3.10), Modicon Premium (all versions), and Modicon Quantum (all versions), which could cause a possible denial of service when reading specific coils and registers in the controller over Modbus.
Severity
No CVSS data available.
CWE
- CWE-248 - Uncaught Exception
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.schneider-electric.com/en/download/do… | x_refsource_CONFIRM |
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | Modicon M580 |
Affected:
firmware version prior to V2.90
|
|
| Schneider Electric SE | Modicon M340 |
Affected:
firmware version prior to V3.10
|
|
| Schneider Electric SE | Modicon Premium |
Affected:
all versions
|
|
| Schneider Electric SE | Modicon Quantum |
Affected:
all versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.247Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "firmware version prior to V2.90"
}
]
},
{
"product": "Modicon M340",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "firmware version prior to V3.10"
}
]
},
{
"product": "Modicon Premium",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"product": "Modicon Quantum",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-248: Uncaught Exception vulnerability exists Modicon M580 (firmware version prior to V2.90), Modicon M340 (firmware version prior to V3.10), Modicon Premium (all versions), and Modicon Quantum (all versions), which could cause a possible denial of service when reading specific coils and registers in the controller over Modbus."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-248",
"description": "CWE-248: Uncaught Exception",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-09-17T19:59:33.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2019-6828",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580",
"version": {
"version_data": [
{
"version_value": "firmware version prior to V2.90"
}
]
}
},
{
"product_name": "Modicon M340",
"version": {
"version_data": [
{
"version_value": "firmware version prior to V3.10"
}
]
}
},
{
"product_name": "Modicon Premium",
"version": {
"version_data": [
{
"version_value": "all versions"
}
]
}
},
{
"product_name": "Modicon Quantum",
"version": {
"version_data": [
{
"version_value": "all versions"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-248: Uncaught Exception vulnerability exists Modicon M580 (firmware version prior to V2.90), Modicon M340 (firmware version prior to V3.10), Modicon Premium (all versions), and Modicon Quantum (all versions), which could cause a possible denial of service when reading specific coils and registers in the controller over Modbus."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-248: Uncaught Exception"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2019-6828",
"datePublished": "2019-09-17T19:59:33.000Z",
"dateReserved": "2019-01-25T00:00:00.000Z",
"dateUpdated": "2024-08-04T20:31:04.247Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6809 (GCVE-0-2019-6809)
Vulnerability from cvelistv5 – Published: 2019-09-17 19:50 – Updated: 2024-08-04 20:31
VLAI
EPSS
VEX
Summary
A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware versions prior to V2.90), Modicon M340 (firmware versions prior to V3.10), Modicon Premium (all versions), Modicon Quantum (all versions), which could cause a possible denial of service when reading invalid data from the controller.
Severity
No CVSS data available.
CWE
- CWE-248 - Uncaught Exception
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.schneider-electric.com/en/download/do… | x_refsource_CONFIRM |
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | Modicon M580 |
Affected:
firmware version prior to V2.90
|
|
| Schneider Electric SE | Modicon M340 |
Affected:
firmware version prior to V3.10
|
|
| Schneider Electric SE | Modicon Premium |
Affected:
all versions
|
|
| Schneider Electric SE | Modicon Quantum |
Affected:
all versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.229Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "firmware version prior to V2.90"
}
]
},
{
"product": "Modicon M340",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "firmware version prior to V3.10"
}
]
},
{
"product": "Modicon Premium",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"product": "Modicon Quantum",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware versions prior to V2.90), Modicon M340 (firmware versions prior to V3.10), Modicon Premium (all versions), Modicon Quantum (all versions), which could cause a possible denial of service when reading invalid data from the controller."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-248",
"description": "CWE-248: Uncaught Exception",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-09-17T19:50:29.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2019-6809",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580",
"version": {
"version_data": [
{
"version_value": "firmware version prior to V2.90"
}
]
}
},
{
"product_name": "Modicon M340",
"version": {
"version_data": [
{
"version_value": "firmware version prior to V3.10"
}
]
}
},
{
"product_name": "Modicon Premium",
"version": {
"version_data": [
{
"version_value": "all versions"
}
]
}
},
{
"product_name": "Modicon Quantum",
"version": {
"version_data": [
{
"version_value": "all versions"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware versions prior to V2.90), Modicon M340 (firmware versions prior to V3.10), Modicon Premium (all versions), Modicon Quantum (all versions), which could cause a possible denial of service when reading invalid data from the controller."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-248: Uncaught Exception"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2019-6809",
"datePublished": "2019-09-17T19:50:29.000Z",
"dateReserved": "2019-01-25T00:00:00.000Z",
"dateUpdated": "2024-08-04T20:31:04.229Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
No mitigation information available for this CWE.
No CAPEC attack patterns related to this CWE.