Common Weakness Enumeration
CWE-121
AllowedStack-based Buffer Overflow
Abstraction: Variant · Status: Draft
A stack-based buffer overflow condition is a condition where the buffer being overwritten is allocated on the stack (i.e., is a local variable or, rarely, a parameter to a function).
5212 vulnerabilities reference this CWE, most recent first.
CVE-2026-2925 (GCVE-0-2026-2925)
Vulnerability from cvelistv5 – Published: 2026-02-22 04:02 – Updated: 2026-02-26 16:24
VLAI
EPSS
VEX
Title
D-Link DWR-M960 Bridge VLAN Configuration Endpoint formBridgeVlan sub_42B5A0 stack-based overflow
Summary
A vulnerability was detected in D-Link DWR-M960 1.01.07. Affected by this issue is the function sub_42B5A0 of the file /boafrm/formBridgeVlan of the component Bridge VLAN Configuration Endpoint. Performing a manipulation of the argument submit-url results in stack-based buffer overflow. The attack can be initiated remotely. The exploit is now public and may be used.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.347272 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.347272 | signaturepermissions-required |
| https://vuldb.com/?submit.754497 | third-party-advisory |
| https://github.com/LX-66-LX/cve-new/issues/20 | exploitissue-tracking |
| https://www.dlink.com/ | product |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2925",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-26T16:22:30.369811Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-26T16:24:22.439Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Bridge VLAN Configuration Endpoint"
],
"product": "DWR-M960",
"vendor": "D-Link",
"versions": [
{
"status": "affected",
"version": "1.01.07"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LX-66-LX (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was detected in D-Link DWR-M960 1.01.07. Affected by this issue is the function sub_42B5A0 of the file /boafrm/formBridgeVlan of the component Bridge VLAN Configuration Endpoint. Performing a manipulation of the argument submit-url results in stack-based buffer overflow. The attack can be initiated remotely. The exploit is now public and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-22T04:02:19.327Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-347272 | D-Link DWR-M960 Bridge VLAN Configuration Endpoint formBridgeVlan sub_42B5A0 stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.347272"
},
{
"name": "VDB-347272 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.347272"
},
{
"name": "Submit #754497 | D-Link DWR-M960 V1.01.07 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.754497"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/LX-66-LX/cve-new/issues/20"
},
{
"tags": [
"product"
],
"url": "https://www.dlink.com/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-02-21T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-02-21T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-02-21T06:03:45.000Z",
"value": "VulDB entry last update"
}
],
"title": "D-Link DWR-M960 Bridge VLAN Configuration Endpoint formBridgeVlan sub_42B5A0 stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-2925",
"datePublished": "2026-02-22T04:02:19.327Z",
"dateReserved": "2026-02-21T04:58:27.633Z",
"dateUpdated": "2026-02-26T16:24:22.439Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2910 (GCVE-0-2026-2910)
Vulnerability from cvelistv5 – Published: 2026-02-22 02:32 – Updated: 2026-02-23 19:17
VLAI
EPSS
VEX
Title
Tenda HG9 formPing6 stack-based overflow
Summary
A flaw has been found in Tenda HG9 300001138. This vulnerability affects unknown code of the file /boaform/formPing6. Executing a manipulation of the argument pingAddr can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been published and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.347219 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.347219 | signaturepermissions-required |
| https://vuldb.com/?submit.755212 | third-party-advisory |
| https://github.com/QIU-DIE/cve-nneeww/issues/12 | exploitissue-tracking |
| https://www.tenda.com.cn/ | product |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2910",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-23T19:17:14.139751Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T19:17:27.114Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LINXI666 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A flaw has been found in Tenda HG9 300001138. This vulnerability affects unknown code of the file /boaform/formPing6. Executing a manipulation of the argument pingAddr can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been published and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-22T02:32:11.075Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-347219 | Tenda HG9 formPing6 stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.347219"
},
{
"name": "VDB-347219 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.347219"
},
{
"name": "Submit #755212 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.755212"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/QIU-DIE/cve-nneeww/issues/12"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-02-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-02-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-02-20T21:20:04.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG9 formPing6 stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-2910",
"datePublished": "2026-02-22T02:32:11.075Z",
"dateReserved": "2026-02-20T20:14:51.686Z",
"dateUpdated": "2026-02-23T19:17:27.114Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2909 (GCVE-0-2026-2909)
Vulnerability from cvelistv5 – Published: 2026-02-22 02:02 – Updated: 2026-02-23 19:18
VLAI
EPSS
VEX
Title
Tenda HG9 Diagnostic Ping Endpoint formPing stack-based overflow
Summary
A vulnerability was detected in Tenda HG9 300001138. This affects an unknown part of the file /boaform/formPing of the component Diagnostic Ping Endpoint. Performing a manipulation of the argument pingAddr results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used.
Severity
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.347218 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.347218 | signaturepermissions-required |
| https://vuldb.com/?submit.755211 | third-party-advisory |
| https://github.com/QIU-DIE/cve-nneeww/issues/11 | exploitissue-tracking |
| https://www.tenda.com.cn/ | product |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2909",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-23T19:18:27.278329Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T19:18:40.226Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Diagnostic Ping Endpoint"
],
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LINXI666 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was detected in Tenda HG9 300001138. This affects an unknown part of the file /boaform/formPing of the component Diagnostic Ping Endpoint. Performing a manipulation of the argument pingAddr results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-22T02:02:14.122Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-347218 | Tenda HG9 Diagnostic Ping Endpoint formPing stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.347218"
},
{
"name": "VDB-347218 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.347218"
},
{
"name": "Submit #755211 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.755211"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/QIU-DIE/cve-nneeww/issues/11"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-02-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-02-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-02-20T21:20:02.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG9 Diagnostic Ping Endpoint formPing stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-2909",
"datePublished": "2026-02-22T02:02:14.122Z",
"dateReserved": "2026-02-20T20:14:48.904Z",
"dateUpdated": "2026-02-23T19:18:40.226Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2908 (GCVE-0-2026-2908)
Vulnerability from cvelistv5 – Published: 2026-02-22 02:02 – Updated: 2026-02-23 19:19
VLAI
EPSS
VEX
Title
Tenda HG9 Loopback Detection Configuration Endpoint formLoopBack stack-based overflow
Summary
A security vulnerability has been detected in Tenda HG9 300001138. Affected by this issue is some unknown functionality of the file /boaform/formLoopBack of the component Loopback Detection Configuration Endpoint. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used.
Severity
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.347217 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.347217 | signaturepermissions-required |
| https://vuldb.com/?submit.755202 | third-party-advisory |
| https://github.com/QIU-DIE/cve-nneeww/issues/10 | exploitissue-tracking |
| https://www.tenda.com.cn/ | product |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2908",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-23T19:19:17.915757Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T19:19:51.049Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Loopback Detection Configuration Endpoint"
],
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LINXI666 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A security vulnerability has been detected in Tenda HG9 300001138. Affected by this issue is some unknown functionality of the file /boaform/formLoopBack of the component Loopback Detection Configuration Endpoint. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-22T02:02:10.921Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-347217 | Tenda HG9 Loopback Detection Configuration Endpoint formLoopBack stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.347217"
},
{
"name": "VDB-347217 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.347217"
},
{
"name": "Submit #755202 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.755202"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/QIU-DIE/cve-nneeww/issues/10"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-02-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-02-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-02-20T21:20:00.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG9 Loopback Detection Configuration Endpoint formLoopBack stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-2908",
"datePublished": "2026-02-22T02:02:10.921Z",
"dateReserved": "2026-02-20T20:14:45.983Z",
"dateUpdated": "2026-02-23T19:19:51.049Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2907 (GCVE-0-2026-2907)
Vulnerability from cvelistv5 – Published: 2026-02-22 01:32 – Updated: 2026-02-23 19:23
VLAI
EPSS
VEX
Title
Tenda HG9 GPON Configuration Endpoint formgponConf stack-based overflow
Summary
A weakness has been identified in Tenda HG9 300001138. Affected by this vulnerability is an unknown functionality of the file /boaform/formgponConf of the component GPON Configuration Endpoint. This manipulation of the argument fmgpon_loid/fmgpon_loid_password causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be used for attacks.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.347216 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.347216 | signaturepermissions-required |
| https://vuldb.com/?submit.755201 | third-party-advisory |
| https://github.com/QIU-DIE/cve-nneeww/issues/9 | exploitissue-tracking |
| https://www.tenda.com.cn/ | product |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2907",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-23T19:22:46.303895Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T19:23:03.755Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"GPON Configuration Endpoint"
],
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LINXI666 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A weakness has been identified in Tenda HG9 300001138. Affected by this vulnerability is an unknown functionality of the file /boaform/formgponConf of the component GPON Configuration Endpoint. This manipulation of the argument fmgpon_loid/fmgpon_loid_password causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be used for attacks."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-22T01:32:12.542Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-347216 | Tenda HG9 GPON Configuration Endpoint formgponConf stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.347216"
},
{
"name": "VDB-347216 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.347216"
},
{
"name": "Submit #755201 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.755201"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/QIU-DIE/cve-nneeww/issues/9"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-02-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-02-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-02-20T21:19:59.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG9 GPON Configuration Endpoint formgponConf stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-2907",
"datePublished": "2026-02-22T01:32:12.542Z",
"dateReserved": "2026-02-20T20:14:43.142Z",
"dateUpdated": "2026-02-23T19:23:03.755Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2906 (GCVE-0-2026-2906)
Vulnerability from cvelistv5 – Published: 2026-02-22 01:32 – Updated: 2026-02-24 15:38
VLAI
EPSS
VEX
Title
Tenda HG9 Samba Configuration Endpoint formSamba stack-based overflow
Summary
A security flaw has been discovered in Tenda HG9 300001138. Affected is an unknown function of the file /boaform/formSamba of the component Samba Configuration Endpoint. The manipulation of the argument sambaCap results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be used for attacks.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.347215 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.347215 | signaturepermissions-required |
| https://vuldb.com/?submit.755193 | third-party-advisory |
| https://github.com/QIU-DIE/cve-nneeww/issues/8 | exploitissue-tracking |
| https://www.tenda.com.cn/ | product |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2906",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-24T15:38:13.838475Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-24T15:38:54.600Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Samba Configuration Endpoint"
],
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LINXI666 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A security flaw has been discovered in Tenda HG9 300001138. Affected is an unknown function of the file /boaform/formSamba of the component Samba Configuration Endpoint. The manipulation of the argument sambaCap results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be used for attacks."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-22T01:32:09.390Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-347215 | Tenda HG9 Samba Configuration Endpoint formSamba stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.347215"
},
{
"name": "VDB-347215 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.347215"
},
{
"name": "Submit #755193 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.755193"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/QIU-DIE/cve-nneeww/issues/8"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-02-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-02-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-02-20T21:19:58.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG9 Samba Configuration Endpoint formSamba stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-2906",
"datePublished": "2026-02-22T01:32:09.390Z",
"dateReserved": "2026-02-20T20:14:40.341Z",
"dateUpdated": "2026-02-24T15:38:54.600Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2905 (GCVE-0-2026-2905)
Vulnerability from cvelistv5 – Published: 2026-02-22 01:02 – Updated: 2026-02-23 19:13
VLAI
EPSS
VEX
Title
Tenda HG9 Wireless Configuration Endpoint formWlanSetup stack-based overflow
Summary
A vulnerability was identified in Tenda HG9 300001138. This impacts an unknown function of the file /boaform/formWlanSetup of the component Wireless Configuration Endpoint. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit is publicly available and might be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.347214 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.347214 | signaturepermissions-required |
| https://vuldb.com/?submit.755167 | third-party-advisory |
| https://github.com/QIU-DIE/cve-nneeww/issues/7 | exploitissue-tracking |
| https://www.tenda.com.cn/ | product |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2905",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-23T19:13:05.204806Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T19:13:59.154Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Wireless Configuration Endpoint"
],
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LINXI666 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was identified in Tenda HG9 300001138. This impacts an unknown function of the file /boaform/formWlanSetup of the component Wireless Configuration Endpoint. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit is publicly available and might be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-22T01:02:10.433Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-347214 | Tenda HG9 Wireless Configuration Endpoint formWlanSetup stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.347214"
},
{
"name": "VDB-347214 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.347214"
},
{
"name": "Submit #755167 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.755167"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/QIU-DIE/cve-nneeww/issues/7"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-02-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-02-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-02-20T21:19:56.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG9 Wireless Configuration Endpoint formWlanSetup stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-2905",
"datePublished": "2026-02-22T01:02:10.433Z",
"dateReserved": "2026-02-20T20:14:32.380Z",
"dateUpdated": "2026-02-23T19:13:59.154Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2886 (GCVE-0-2026-2886)
Vulnerability from cvelistv5 – Published: 2026-02-21 21:02 – Updated: 2026-02-23 19:31
VLAI
EPSS
VEX
Title
Tenda A21 SetOnlineDevName set_device_name stack-based overflow
Summary
A weakness has been identified in Tenda A21 1.0.0.0. This affects the function set_device_name of the file /goform/SetOnlineDevName. This manipulation of the argument devName causes stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been made available to the public and could be used for attacks.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.347180 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.347180 | signaturepermissions-required |
| https://vuldb.com/?submit.754640 | third-party-advisory |
| https://github.com/QIU-DIE/cve-nneeww/issues/6 | exploitissue-tracking |
| https://www.tenda.com.cn/ | product |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2886",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-23T19:31:02.671993Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T19:31:15.738Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "A21",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.0"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "hhsw34 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A weakness has been identified in Tenda A21 1.0.0.0. This affects the function set_device_name of the file /goform/SetOnlineDevName. This manipulation of the argument devName causes stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been made available to the public and could be used for attacks."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-21T21:02:11.930Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-347180 | Tenda A21 SetOnlineDevName set_device_name stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.347180"
},
{
"name": "VDB-347180 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.347180"
},
{
"name": "Submit #754640 | Tenda A21 V1.0.0.0 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.754640"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/QIU-DIE/cve-nneeww/issues/6"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-02-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-02-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-02-20T18:09:49.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda A21 SetOnlineDevName set_device_name stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-2886",
"datePublished": "2026-02-21T21:02:11.930Z",
"dateReserved": "2026-02-20T17:04:45.674Z",
"dateUpdated": "2026-02-23T19:31:15.738Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2885 (GCVE-0-2026-2885)
Vulnerability from cvelistv5 – Published: 2026-02-21 20:32 – Updated: 2026-02-23 19:32
VLAI
EPSS
VEX
Title
D-Link DWR-M960 formIpv6Setup sub_469104 stack-based overflow
Summary
A security flaw has been discovered in D-Link DWR-M960 1.01.07. The impacted element is the function sub_469104 of the file /boafrm/formIpv6Setup. The manipulation of the argument submit-url results in stack-based buffer overflow. The attack may be performed from remote. The exploit has been released to the public and may be used for attacks.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.347179 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.347179 | signaturepermissions-required |
| https://vuldb.com/?submit.754496 | third-party-advisory |
| https://github.com/LX-66-LX/cve-new/issues/19 | exploitissue-tracking |
| https://www.dlink.com/ | product |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2885",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-23T19:31:48.470184Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T19:32:07.007Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "DWR-M960",
"vendor": "D-Link",
"versions": [
{
"status": "affected",
"version": "1.01.07"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LX-66-LX (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A security flaw has been discovered in D-Link DWR-M960 1.01.07. The impacted element is the function sub_469104 of the file /boafrm/formIpv6Setup. The manipulation of the argument submit-url results in stack-based buffer overflow. The attack may be performed from remote. The exploit has been released to the public and may be used for attacks."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-21T20:32:15.464Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-347179 | D-Link DWR-M960 formIpv6Setup sub_469104 stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.347179"
},
{
"name": "VDB-347179 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.347179"
},
{
"name": "Submit #754496 | D-Link DWR-M960 V1.01.07 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.754496"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/LX-66-LX/cve-new/issues/19"
},
{
"tags": [
"product"
],
"url": "https://www.dlink.com/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-02-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-02-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-02-20T18:04:32.000Z",
"value": "VulDB entry last update"
}
],
"title": "D-Link DWR-M960 formIpv6Setup sub_469104 stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-2885",
"datePublished": "2026-02-21T20:32:15.464Z",
"dateReserved": "2026-02-20T16:59:21.658Z",
"dateUpdated": "2026-02-23T19:32:07.007Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2884 (GCVE-0-2026-2884)
Vulnerability from cvelistv5 – Published: 2026-02-21 20:32 – Updated: 2026-02-23 19:32
VLAI
EPSS
VEX
Title
D-Link DWR-M960 WAN Interface Setting formWanConfigSetup sub_41914C stack-based overflow
Summary
A vulnerability was identified in D-Link DWR-M960 1.01.07. The affected element is the function sub_41914C of the file /boafrm/formWanConfigSetup of the component WAN Interface Setting Handler. The manipulation of the argument submit-url leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is publicly available and might be used.
Severity
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.347178 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.347178 | signaturepermissions-required |
| https://vuldb.com/?submit.754493 | third-party-advisory |
| https://github.com/LX-66-LX/cve-new/issues/18 | exploitissue-tracking |
| https://www.dlink.com/ | product |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2884",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-23T19:32:39.183003Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T19:32:58.848Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"WAN Interface Setting Handler"
],
"product": "DWR-M960",
"vendor": "D-Link",
"versions": [
{
"status": "affected",
"version": "1.01.07"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LX-66-LX (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was identified in D-Link DWR-M960 1.01.07. The affected element is the function sub_41914C of the file /boafrm/formWanConfigSetup of the component WAN Interface Setting Handler. The manipulation of the argument submit-url leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is publicly available and might be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-21T20:32:09.601Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-347178 | D-Link DWR-M960 WAN Interface Setting formWanConfigSetup sub_41914C stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.347178"
},
{
"name": "VDB-347178 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.347178"
},
{
"name": "Submit #754493 | D-Link DWR-M960 V1.01.07 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.754493"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/LX-66-LX/cve-new/issues/18"
},
{
"tags": [
"product"
],
"url": "https://www.dlink.com/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-02-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-02-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-02-20T18:04:31.000Z",
"value": "VulDB entry last update"
}
],
"title": "D-Link DWR-M960 WAN Interface Setting formWanConfigSetup sub_41914C stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-2884",
"datePublished": "2026-02-21T20:32:09.601Z",
"dateReserved": "2026-02-20T16:59:18.740Z",
"dateUpdated": "2026-02-23T19:32:58.848Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
Mitigation MIT-10
Operation
Build and Compilation
Strategy: Environment Hardening
- Use automatic buffer overflow detection mechanisms that are offered by certain compilers or compiler extensions. Examples include: the Microsoft Visual Studio /GS flag, Fedora/Red Hat FORTIFY_SOURCE GCC flag, StackGuard, and ProPolice, which provide various mechanisms including canary-based detection and range/index checking.
- D3-SFCV (Stack Frame Canary Validation) from D3FEND [REF-1334] discusses canary-based detection in detail.
Mitigation
Architecture and Design
Use an abstraction library to abstract away risky APIs. Not a complete solution.
Mitigation
Implementation
Implement and perform bounds checking on input.
Mitigation
Implementation
Do not use dangerous functions such as gets. Use safer, equivalent functions which check for boundary errors.
Mitigation MIT-11
Operation
Build and Compilation
Strategy: Environment Hardening
- Run or compile the software using features or extensions that randomly arrange the positions of a program's executable and libraries in memory. Because this makes the addresses unpredictable, it can prevent an attacker from reliably jumping to exploitable code.
- Examples include Address Space Layout Randomization (ASLR) [REF-58] [REF-60] and Position-Independent Executables (PIE) [REF-64]. Imported modules may be similarly realigned if their default memory addresses conflict with other modules, in a process known as "rebasing" (for Windows) and "prelinking" (for Linux) [REF-1332] using randomly generated addresses. ASLR for libraries cannot be used in conjunction with prelink since it would require relocating the libraries at run-time, defeating the whole purpose of prelinking.
- For more information on these techniques see D3-SAOR (Segment Address Offset Randomization) from D3FEND [REF-1335].
No CAPEC attack patterns related to this CWE.