    CVE-2018-10628 (GCVE-0-2018-10628)

    Vulnerability from cvelistv5 – Published: 2018-07-24 18:00 – Updated: 2024-09-16 19:09
    VLAI
    Summary
    AVEVA InTouch 2014 R2 SP1 and prior, InTouch 2017, InTouch 2017 Update 1, and InTouch 2017 Update 2 allow an unauthenticated user to send a specially crafted packet that could overflow the buffer on a locale not using a dot floating point separator. Exploitation could allow remote code execution under the privileges of the InTouch View process.
    Severity
    No CVSS data available.
    CWE
    • CWE-121 - STACK-BASED BUFFER OVERFLOW CWE-121
    Assigner
    References
    Impacted products
    Vendor Product Version
    AVEVA Software, LLC. InTouch Affected: 2014 R2 SP1 and prior
    Affected: 2017
    Affected: 2017 Update 1
    Affected: 2017 Update 2
    Create a notification for this product.
    Date Public
    2018-07-19 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T07:46:46.397Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-200-02"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://sw.aveva.com/hubfs/assets-2018/pdf/security-bulletin/SecurityBulletin_LFSec127%28003%29.pdf"
              },
              {
                "name": "104864",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/104864"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "InTouch",
              "vendor": "AVEVA Software, LLC.",
              "versions": [
                {
                  "status": "affected",
                  "version": "2014 R2 SP1 and prior"
                },
                {
                  "status": "affected",
                  "version": "2017"
                },
                {
                  "status": "affected",
                  "version": "2017 Update 1"
                },
                {
                  "status": "affected",
                  "version": "2017 Update 2"
                }
              ]
            }
          ],
          "datePublic": "2018-07-19T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "AVEVA InTouch 2014 R2 SP1 and prior, InTouch 2017, InTouch 2017 Update 1, and InTouch 2017 Update 2 allow an unauthenticated user to send a specially crafted packet that could overflow the buffer on a locale not using a dot floating point separator. Exploitation could allow remote code execution under the privileges of the InTouch View process."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "STACK-BASED BUFFER OVERFLOW CWE-121",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-07-25T09:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-200-02"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://sw.aveva.com/hubfs/assets-2018/pdf/security-bulletin/SecurityBulletin_LFSec127%28003%29.pdf"
            },
            {
              "name": "104864",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/104864"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2018-07-19T00:00:00",
              "ID": "CVE-2018-10628",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "InTouch",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "2014 R2 SP1 and prior"
                              },
                              {
                                "version_value": "2017"
                              },
                              {
                                "version_value": "2017 Update 1"
                              },
                              {
                                "version_value": "2017 Update 2"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "AVEVA Software, LLC."
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "AVEVA InTouch 2014 R2 SP1 and prior, InTouch 2017, InTouch 2017 Update 1, and InTouch 2017 Update 2 allow an unauthenticated user to send a specially crafted packet that could overflow the buffer on a locale not using a dot floating point separator. Exploitation could allow remote code execution under the privileges of the InTouch View process."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "STACK-BASED BUFFER OVERFLOW CWE-121"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-200-02",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-200-02"
                },
                {
                  "name": "https://sw.aveva.com/hubfs/assets-2018/pdf/security-bulletin/SecurityBulletin_LFSec127(003).pdf",
                  "refsource": "CONFIRM",
                  "url": "https://sw.aveva.com/hubfs/assets-2018/pdf/security-bulletin/SecurityBulletin_LFSec127(003).pdf"
                },
                {
                  "name": "104864",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/104864"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-10628",
        "datePublished": "2018-07-24T18:00:00.000Z",
        "dateReserved": "2018-05-01T00:00:00.000Z",
        "dateUpdated": "2024-09-16T19:09:25.647Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }