6 vulnerabilities found for workstationst by ge

FKIE_CVE-2022-37952

Vulnerability from fkie_nvd - Published: 2022-08-25 18:15 - Updated: 2024-11-21 07:15
Summary
A reflected cross-site scripting (XSS) vulnerability exists in the iHistorian Data Display of WorkstationST (<v07.09.15) could allow an attacker to compromise a victim's browser. WorkstationST is only deployed in specific, controlled environments rendering attack complexity significantly higher than if the attack were conducted on the software in isolation. WorkstationST v07.09.15 can be found in ControlST v07.09.07 SP8 and greater.
Impacted products
Vendor Product Version
ge workstationst *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ge:workstationst:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D27569A3-96FD-478C-A6B0-7E338171AE3D",
              "versionEndExcluding": "07.09.15",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A reflected cross-site scripting (XSS) vulnerability exists in the iHistorian Data Display of WorkstationST (\u003cv07.09.15) could allow an attacker to compromise a victim\u0027s browser. WorkstationST is only deployed in specific, controlled environments rendering attack complexity significantly higher than if the attack were conducted on the software in isolation. WorkstationST v07.09.15 can be found in ControlST v07.09.07 SP8 and greater."
    },
    {
      "lang": "es",
      "value": "Se presenta una vulnerabilidad de tipo cross-site scripting (XSS) reflejado en iHistorian Data Display de WorkstationST (versiones anteriores a v07.09.15) que podr\u00eda permitir a un atacante comprometer el navegador de una v\u00edctima. WorkstationST s\u00f3lo es desplegado en entornos espec\u00edficos y controlados, lo que hace que la complejidad del ataque sea significativamente mayor que si el ataque es conducido sobre el software de forma aislada. WorkstationST versi\u00f3n v07.09.15, puede encontrarse en ControlST versiones v07.09.07 SP8 y superiores."
    }
  ],
  "id": "CVE-2022-37952",
  "lastModified": "2024-11-21T07:15:25.883",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.7,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.6,
        "impactScore": 2.7,
        "source": "GEPowerCVD@ge.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.1,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-08-25T18:15:10.813",
  "references": [
    {
      "source": "GEPowerCVD@ge.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.ge.com/content/dam/cyber_security/global/en_US/pdfs/2022-08-23_WorkstationST_Reflected_XSS.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.ge.com/content/dam/cyber_security/global/en_US/pdfs/2022-08-23_WorkstationST_Reflected_XSS.pdf"
    }
  ],
  "sourceIdentifier": "GEPowerCVD@ge.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "GEPowerCVD@ge.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2022-37953

Vulnerability from fkie_nvd - Published: 2022-08-25 18:15 - Updated: 2024-11-21 07:15
Summary
An HTTP response splitting vulnerability exists in the AM Gateway Challenge-Response dialog of WorkstationST (<v07.09.15) and could allow an attacker to compromise a victim's browser/session. WorkstationST is only deployed in specific, controlled environments rendering attack complexity significantly higher than if the attack were conducted on the software in isolation. WorkstationST v07.09.15 can be found in ControlST v07.09.07 SP8 and greater.
Impacted products
Vendor Product Version
ge workstationst *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ge:workstationst:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D27569A3-96FD-478C-A6B0-7E338171AE3D",
              "versionEndExcluding": "07.09.15",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An HTTP response splitting vulnerability exists in the AM Gateway Challenge-Response dialog of WorkstationST (\u003cv07.09.15) and could allow an attacker to compromise a victim\u0027s browser/session. WorkstationST is only deployed in specific, controlled environments rendering attack complexity significantly higher than if the attack were conducted on the software in isolation. WorkstationST v07.09.15 can be found in ControlST v07.09.07 SP8 and greater."
    },
    {
      "lang": "es",
      "value": "Se presenta una vulnerabilidad de divisi\u00f3n de respuesta HTTP en el di\u00e1logo de Respuesta de Desaf\u00edo de Puerta de Enlace AM de WorkstationST (versiones anteriores a v07.09.15) y podr\u00eda permitir a un atacante comprometer el navegador/sesi\u00f3n de una v\u00edctima. WorkstationST s\u00f3lo es desplegado en entornos espec\u00edficos y controlados, lo que hace que la complejidad del ataque sea significativamente mayor que si el ataque es conducido en el software de forma aislada. WorkstationST versi\u00f3n v07.09.15 puede encontrarse en ControlST versiones v07.09.07 SP8 y superiores."
    }
  ],
  "id": "CVE-2022-37953",
  "lastModified": "2024-11-21T07:15:26.010",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.7,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.6,
        "impactScore": 2.7,
        "source": "GEPowerCVD@ge.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.1,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-08-25T18:15:10.897",
  "references": [
    {
      "source": "GEPowerCVD@ge.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.ge.com/content/dam/cyber_security/global/en_US/pdfs/2022-08-23_WorkstationST_Response_Splitting.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.ge.com/content/dam/cyber_security/global/en_US/pdfs/2022-08-23_WorkstationST_Response_Splitting.pdf"
    }
  ],
  "sourceIdentifier": "GEPowerCVD@ge.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-113"
        }
      ],
      "source": "GEPowerCVD@ge.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

CVE-2022-37952 (GCVE-0-2022-37952)

Vulnerability from cvelistv5 – Published: 2022-08-25 17:26 – Updated: 2024-09-17 01:41
VLAI?
Title
WorkstationST - Reflected XSS in iHistorian Data Display Tags
Summary
A reflected cross-site scripting (XSS) vulnerability exists in the iHistorian Data Display of WorkstationST (<v07.09.15) could allow an attacker to compromise a victim's browser. WorkstationST is only deployed in specific, controlled environments rendering attack complexity significantly higher than if the attack were conducted on the software in isolation. WorkstationST v07.09.15 can be found in ControlST v07.09.07 SP8 and greater.
CWE
  • CWE-79 - Cross-site Scripting (XSS)
Assigner
References
Impacted products
Vendor Product Version
GE Gas Power WorkstationST Affected: unspecified , < 07.09.15 (custom)
Create a notification for this product.
Credits
GE Gas Power would like to thank Ammar Majali for his evaluation and responsible disclosure of this vulnerability.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:37:42.619Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.ge.com/content/dam/cyber_security/global/en_US/pdfs/2022-08-23_WorkstationST_Reflected_XSS.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "WorkstationST",
          "vendor": "GE Gas Power",
          "versions": [
            {
              "lessThan": "07.09.15",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "GE Gas Power would like to thank Ammar Majali for his evaluation and responsible disclosure of this vulnerability."
        }
      ],
      "datePublic": "2022-08-23T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A reflected cross-site scripting (XSS) vulnerability exists in the iHistorian Data Display of WorkstationST (\u003cv07.09.15) could allow an attacker to compromise a victim\u0027s browser. WorkstationST is only deployed in specific, controlled environments rendering attack complexity significantly higher than if the attack were conducted on the software in isolation. WorkstationST v07.09.15 can be found in ControlST v07.09.07 SP8 and greater."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Cross-site Scripting (XSS)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-25T17:26:10",
        "orgId": "2cf0fb33-79e2-44e0-beb8-826cc5ce3250",
        "shortName": "GE GP"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.ge.com/content/dam/cyber_security/global/en_US/pdfs/2022-08-23_WorkstationST_Reflected_XSS.pdf"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Upgrade to Workstation \u003e= 7.09.15 which can be found in ControlST 7.09.07c SP8 and higher."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "WorkstationST - Reflected XSS in iHistorian Data Display Tags",
      "workarounds": [
        {
          "lang": "en",
          "value": "Customers should follow the guidance laid out in GEH-6839. The best practices described in that document limit the likelihood and impact of a wide variety of attacks."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "GEPowerCVD@ge.com",
          "DATE_PUBLIC": "2022-08-23T21:00:00.000Z",
          "ID": "CVE-2022-37952",
          "STATE": "PUBLIC",
          "TITLE": "WorkstationST - Reflected XSS in iHistorian Data Display Tags"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "WorkstationST",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "07.09.15"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "GE Gas Power"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "GE Gas Power would like to thank Ammar Majali for his evaluation and responsible disclosure of this vulnerability."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A reflected cross-site scripting (XSS) vulnerability exists in the iHistorian Data Display of WorkstationST (\u003cv07.09.15) could allow an attacker to compromise a victim\u0027s browser. WorkstationST is only deployed in specific, controlled environments rendering attack complexity significantly higher than if the attack were conducted on the software in isolation. WorkstationST v07.09.15 can be found in ControlST v07.09.07 SP8 and greater."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-79 Cross-site Scripting (XSS)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.ge.com/content/dam/cyber_security/global/en_US/pdfs/2022-08-23_WorkstationST_Reflected_XSS.pdf",
              "refsource": "CONFIRM",
              "url": "https://www.ge.com/content/dam/cyber_security/global/en_US/pdfs/2022-08-23_WorkstationST_Reflected_XSS.pdf"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Upgrade to Workstation \u003e= 7.09.15 which can be found in ControlST 7.09.07c SP8 and higher."
          }
        ],
        "source": {
          "discovery": "EXTERNAL"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "Customers should follow the guidance laid out in GEH-6839. The best practices described in that document limit the likelihood and impact of a wide variety of attacks."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2cf0fb33-79e2-44e0-beb8-826cc5ce3250",
    "assignerShortName": "GE GP",
    "cveId": "CVE-2022-37952",
    "datePublished": "2022-08-25T17:26:10.090096Z",
    "dateReserved": "2022-08-08T00:00:00",
    "dateUpdated": "2024-09-17T01:41:41.508Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-37953 (GCVE-0-2022-37953)

Vulnerability from cvelistv5 – Published: 2022-08-25 17:26 – Updated: 2024-09-16 18:09
VLAI?
Title
WorkstationST - Response Splitting in AM Gateway Challenge-Response
Summary
An HTTP response splitting vulnerability exists in the AM Gateway Challenge-Response dialog of WorkstationST (<v07.09.15) and could allow an attacker to compromise a victim's browser/session. WorkstationST is only deployed in specific, controlled environments rendering attack complexity significantly higher than if the attack were conducted on the software in isolation. WorkstationST v07.09.15 can be found in ControlST v07.09.07 SP8 and greater.
CWE
  • CWE-113 - Improper Neutralization of CRLF Sequences in HTTP Headers ('HTTP Response Splitting')
Assigner
References
Impacted products
Vendor Product Version
GE Gas Power WorkstationST Affected: unspecified , < 07.09.15 (custom)
Create a notification for this product.
Credits
GE Gas Power would like to thank Ammar Majali for his evaluation and responsible disclosure of this vulnerability.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:37:42.553Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.ge.com/content/dam/cyber_security/global/en_US/pdfs/2022-08-23_WorkstationST_Response_Splitting.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "WorkstationST",
          "vendor": "GE Gas Power",
          "versions": [
            {
              "lessThan": "07.09.15",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "GE Gas Power would like to thank Ammar Majali for his evaluation and responsible disclosure of this vulnerability."
        }
      ],
      "datePublic": "2022-08-23T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An HTTP response splitting vulnerability exists in the AM Gateway Challenge-Response dialog of WorkstationST (\u003cv07.09.15) and could allow an attacker to compromise a victim\u0027s browser/session. WorkstationST is only deployed in specific, controlled environments rendering attack complexity significantly higher than if the attack were conducted on the software in isolation. WorkstationST v07.09.15 can be found in ControlST v07.09.07 SP8 and greater."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-113",
              "description": "CWE-113 Improper Neutralization of CRLF Sequences in HTTP Headers (\u0027HTTP Response Splitting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-25T17:26:02",
        "orgId": "2cf0fb33-79e2-44e0-beb8-826cc5ce3250",
        "shortName": "GE GP"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.ge.com/content/dam/cyber_security/global/en_US/pdfs/2022-08-23_WorkstationST_Response_Splitting.pdf"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Upgrade to Workstation \u003e= 7.09.15 which can be found in ControlST 7.09.07c SP8 and higher."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "WorkstationST - Response Splitting in AM Gateway Challenge-Response",
      "workarounds": [
        {
          "lang": "en",
          "value": "Customers should follow the guidance laid out in GEH-6839. The best practices described in that document limit the likelihood and impact of a wide variety of attacks."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "GEPowerCVD@ge.com",
          "DATE_PUBLIC": "2022-08-23T21:00:00.000Z",
          "ID": "CVE-2022-37953",
          "STATE": "PUBLIC",
          "TITLE": "WorkstationST - Response Splitting in AM Gateway Challenge-Response"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "WorkstationST",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "07.09.15"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "GE Gas Power"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "GE Gas Power would like to thank Ammar Majali for his evaluation and responsible disclosure of this vulnerability."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An HTTP response splitting vulnerability exists in the AM Gateway Challenge-Response dialog of WorkstationST (\u003cv07.09.15) and could allow an attacker to compromise a victim\u0027s browser/session. WorkstationST is only deployed in specific, controlled environments rendering attack complexity significantly higher than if the attack were conducted on the software in isolation. WorkstationST v07.09.15 can be found in ControlST v07.09.07 SP8 and greater."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-113 Improper Neutralization of CRLF Sequences in HTTP Headers (\u0027HTTP Response Splitting\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.ge.com/content/dam/cyber_security/global/en_US/pdfs/2022-08-23_WorkstationST_Response_Splitting.pdf",
              "refsource": "CONFIRM",
              "url": "https://www.ge.com/content/dam/cyber_security/global/en_US/pdfs/2022-08-23_WorkstationST_Response_Splitting.pdf"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Upgrade to Workstation \u003e= 7.09.15 which can be found in ControlST 7.09.07c SP8 and higher."
          }
        ],
        "source": {
          "discovery": "EXTERNAL"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "Customers should follow the guidance laid out in GEH-6839. The best practices described in that document limit the likelihood and impact of a wide variety of attacks."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2cf0fb33-79e2-44e0-beb8-826cc5ce3250",
    "assignerShortName": "GE GP",
    "cveId": "CVE-2022-37953",
    "datePublished": "2022-08-25T17:26:02.044195Z",
    "dateReserved": "2022-08-08T00:00:00",
    "dateUpdated": "2024-09-16T18:09:11.130Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-37952 (GCVE-0-2022-37952)

Vulnerability from nvd – Published: 2022-08-25 17:26 – Updated: 2024-09-17 01:41
VLAI?
Title
WorkstationST - Reflected XSS in iHistorian Data Display Tags
Summary
A reflected cross-site scripting (XSS) vulnerability exists in the iHistorian Data Display of WorkstationST (<v07.09.15) could allow an attacker to compromise a victim's browser. WorkstationST is only deployed in specific, controlled environments rendering attack complexity significantly higher than if the attack were conducted on the software in isolation. WorkstationST v07.09.15 can be found in ControlST v07.09.07 SP8 and greater.
CWE
  • CWE-79 - Cross-site Scripting (XSS)
Assigner
References
Impacted products
Vendor Product Version
GE Gas Power WorkstationST Affected: unspecified , < 07.09.15 (custom)
Create a notification for this product.
Credits
GE Gas Power would like to thank Ammar Majali for his evaluation and responsible disclosure of this vulnerability.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:37:42.619Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.ge.com/content/dam/cyber_security/global/en_US/pdfs/2022-08-23_WorkstationST_Reflected_XSS.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "WorkstationST",
          "vendor": "GE Gas Power",
          "versions": [
            {
              "lessThan": "07.09.15",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "GE Gas Power would like to thank Ammar Majali for his evaluation and responsible disclosure of this vulnerability."
        }
      ],
      "datePublic": "2022-08-23T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A reflected cross-site scripting (XSS) vulnerability exists in the iHistorian Data Display of WorkstationST (\u003cv07.09.15) could allow an attacker to compromise a victim\u0027s browser. WorkstationST is only deployed in specific, controlled environments rendering attack complexity significantly higher than if the attack were conducted on the software in isolation. WorkstationST v07.09.15 can be found in ControlST v07.09.07 SP8 and greater."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Cross-site Scripting (XSS)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-25T17:26:10",
        "orgId": "2cf0fb33-79e2-44e0-beb8-826cc5ce3250",
        "shortName": "GE GP"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.ge.com/content/dam/cyber_security/global/en_US/pdfs/2022-08-23_WorkstationST_Reflected_XSS.pdf"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Upgrade to Workstation \u003e= 7.09.15 which can be found in ControlST 7.09.07c SP8 and higher."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "WorkstationST - Reflected XSS in iHistorian Data Display Tags",
      "workarounds": [
        {
          "lang": "en",
          "value": "Customers should follow the guidance laid out in GEH-6839. The best practices described in that document limit the likelihood and impact of a wide variety of attacks."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "GEPowerCVD@ge.com",
          "DATE_PUBLIC": "2022-08-23T21:00:00.000Z",
          "ID": "CVE-2022-37952",
          "STATE": "PUBLIC",
          "TITLE": "WorkstationST - Reflected XSS in iHistorian Data Display Tags"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "WorkstationST",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "07.09.15"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "GE Gas Power"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "GE Gas Power would like to thank Ammar Majali for his evaluation and responsible disclosure of this vulnerability."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A reflected cross-site scripting (XSS) vulnerability exists in the iHistorian Data Display of WorkstationST (\u003cv07.09.15) could allow an attacker to compromise a victim\u0027s browser. WorkstationST is only deployed in specific, controlled environments rendering attack complexity significantly higher than if the attack were conducted on the software in isolation. WorkstationST v07.09.15 can be found in ControlST v07.09.07 SP8 and greater."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-79 Cross-site Scripting (XSS)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.ge.com/content/dam/cyber_security/global/en_US/pdfs/2022-08-23_WorkstationST_Reflected_XSS.pdf",
              "refsource": "CONFIRM",
              "url": "https://www.ge.com/content/dam/cyber_security/global/en_US/pdfs/2022-08-23_WorkstationST_Reflected_XSS.pdf"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Upgrade to Workstation \u003e= 7.09.15 which can be found in ControlST 7.09.07c SP8 and higher."
          }
        ],
        "source": {
          "discovery": "EXTERNAL"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "Customers should follow the guidance laid out in GEH-6839. The best practices described in that document limit the likelihood and impact of a wide variety of attacks."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2cf0fb33-79e2-44e0-beb8-826cc5ce3250",
    "assignerShortName": "GE GP",
    "cveId": "CVE-2022-37952",
    "datePublished": "2022-08-25T17:26:10.090096Z",
    "dateReserved": "2022-08-08T00:00:00",
    "dateUpdated": "2024-09-17T01:41:41.508Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-37953 (GCVE-0-2022-37953)

Vulnerability from nvd – Published: 2022-08-25 17:26 – Updated: 2024-09-16 18:09
VLAI?
Title
WorkstationST - Response Splitting in AM Gateway Challenge-Response
Summary
An HTTP response splitting vulnerability exists in the AM Gateway Challenge-Response dialog of WorkstationST (<v07.09.15) and could allow an attacker to compromise a victim's browser/session. WorkstationST is only deployed in specific, controlled environments rendering attack complexity significantly higher than if the attack were conducted on the software in isolation. WorkstationST v07.09.15 can be found in ControlST v07.09.07 SP8 and greater.
CWE
  • CWE-113 - Improper Neutralization of CRLF Sequences in HTTP Headers ('HTTP Response Splitting')
Assigner
References
Impacted products
Vendor Product Version
GE Gas Power WorkstationST Affected: unspecified , < 07.09.15 (custom)
Create a notification for this product.
Credits
GE Gas Power would like to thank Ammar Majali for his evaluation and responsible disclosure of this vulnerability.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:37:42.553Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.ge.com/content/dam/cyber_security/global/en_US/pdfs/2022-08-23_WorkstationST_Response_Splitting.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "WorkstationST",
          "vendor": "GE Gas Power",
          "versions": [
            {
              "lessThan": "07.09.15",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "GE Gas Power would like to thank Ammar Majali for his evaluation and responsible disclosure of this vulnerability."
        }
      ],
      "datePublic": "2022-08-23T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An HTTP response splitting vulnerability exists in the AM Gateway Challenge-Response dialog of WorkstationST (\u003cv07.09.15) and could allow an attacker to compromise a victim\u0027s browser/session. WorkstationST is only deployed in specific, controlled environments rendering attack complexity significantly higher than if the attack were conducted on the software in isolation. WorkstationST v07.09.15 can be found in ControlST v07.09.07 SP8 and greater."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-113",
              "description": "CWE-113 Improper Neutralization of CRLF Sequences in HTTP Headers (\u0027HTTP Response Splitting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-25T17:26:02",
        "orgId": "2cf0fb33-79e2-44e0-beb8-826cc5ce3250",
        "shortName": "GE GP"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.ge.com/content/dam/cyber_security/global/en_US/pdfs/2022-08-23_WorkstationST_Response_Splitting.pdf"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Upgrade to Workstation \u003e= 7.09.15 which can be found in ControlST 7.09.07c SP8 and higher."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "WorkstationST - Response Splitting in AM Gateway Challenge-Response",
      "workarounds": [
        {
          "lang": "en",
          "value": "Customers should follow the guidance laid out in GEH-6839. The best practices described in that document limit the likelihood and impact of a wide variety of attacks."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "GEPowerCVD@ge.com",
          "DATE_PUBLIC": "2022-08-23T21:00:00.000Z",
          "ID": "CVE-2022-37953",
          "STATE": "PUBLIC",
          "TITLE": "WorkstationST - Response Splitting in AM Gateway Challenge-Response"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "WorkstationST",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "07.09.15"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "GE Gas Power"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "GE Gas Power would like to thank Ammar Majali for his evaluation and responsible disclosure of this vulnerability."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An HTTP response splitting vulnerability exists in the AM Gateway Challenge-Response dialog of WorkstationST (\u003cv07.09.15) and could allow an attacker to compromise a victim\u0027s browser/session. WorkstationST is only deployed in specific, controlled environments rendering attack complexity significantly higher than if the attack were conducted on the software in isolation. WorkstationST v07.09.15 can be found in ControlST v07.09.07 SP8 and greater."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-113 Improper Neutralization of CRLF Sequences in HTTP Headers (\u0027HTTP Response Splitting\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.ge.com/content/dam/cyber_security/global/en_US/pdfs/2022-08-23_WorkstationST_Response_Splitting.pdf",
              "refsource": "CONFIRM",
              "url": "https://www.ge.com/content/dam/cyber_security/global/en_US/pdfs/2022-08-23_WorkstationST_Response_Splitting.pdf"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Upgrade to Workstation \u003e= 7.09.15 which can be found in ControlST 7.09.07c SP8 and higher."
          }
        ],
        "source": {
          "discovery": "EXTERNAL"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "Customers should follow the guidance laid out in GEH-6839. The best practices described in that document limit the likelihood and impact of a wide variety of attacks."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2cf0fb33-79e2-44e0-beb8-826cc5ce3250",
    "assignerShortName": "GE GP",
    "cveId": "CVE-2022-37953",
    "datePublished": "2022-08-25T17:26:02.044195Z",
    "dateReserved": "2022-08-08T00:00:00",
    "dateUpdated": "2024-09-16T18:09:11.130Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}