Vulnerabilites related to netgear - wn3000rpv2
var-202012-1182
Vulnerability from variot
Certain NETGEAR devices are affected by stored XSS. This affects D7800 before 1.0.1.56, R7800 before 1.0.2.68, RAX120 before 1.0.0.78, RBK22 before 2.3.5.26, RBR20 before 2.3.5.26, RBS20 before 2.3.5.26, RBK40 before 2.3.5.30, RBR40 before 2.3.5.30, RBS40 before 2.3.5.30, RBK50 before 2.3.5.30, RBR50 before 2.3.5.30, RBS50 before 2.3.5.30, and WN3000RPv2 before 1.0.0.78. plural NETGEAR A cross-site scripting vulnerability exists in the device.Information may be obtained and information may be tampered with
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202012-1182", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "wn3000rpv2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.78" }, { "model": "rbk22", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.5.26" }, { "model": "rbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.5.30" }, { "model": "rbr20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.5.26" }, { "model": "rbs40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.5.30" }, { "model": "rbk40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.5.30" }, { "model": "rbk50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.5.30" }, { "model": "r7800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.68" }, { "model": "d7800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.56" }, { "model": "rax120", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.78" }, { "model": "rbs20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.5.26" }, { "model": "rbs50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.5.30" }, { "model": "rbr50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.5.30" }, { "model": "rbk50", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax120", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr20", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk22", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs20", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d7800", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7800", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-014997" }, { "db": "NVD", "id": "CVE-2020-35807" } ] }, "cve": "CVE-2020-35807", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 3.5, "confidentialityImpact": "NONE", "exploitabilityScore": 6.8, "id": "CVE-2020-35807", "impactScore": 2.9, "integrityImpact": "PARTIAL", "severity": "LOW", "trust": 1.8, "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 1.7, "id": "CVE-2020-35807", "impactScore": 2.7, "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "cve@mitre.org", "availabilityImpact": "NONE", "baseScore": 6.0, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.8, "id": "CVE-2020-35807", "impactScore": 5.2, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 4.8, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "CVE-2020-35807", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "High", "scope": "Changed", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2020-35807", "trust": 1.0, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2020-35807", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "CVE-2020-35807", "trust": 0.8, "value": "Medium" }, { "author": "CNNVD", "id": "CNNVD-202012-1791", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-014997" }, { "db": "CNNVD", "id": "CNNVD-202012-1791" }, { "db": "NVD", "id": "CVE-2020-35807" }, { "db": "NVD", "id": "CVE-2020-35807" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by stored XSS. This affects D7800 before 1.0.1.56, R7800 before 1.0.2.68, RAX120 before 1.0.0.78, RBK22 before 2.3.5.26, RBR20 before 2.3.5.26, RBS20 before 2.3.5.26, RBK40 before 2.3.5.30, RBR40 before 2.3.5.30, RBS40 before 2.3.5.30, RBK50 before 2.3.5.30, RBR50 before 2.3.5.30, RBS50 before 2.3.5.30, and WN3000RPv2 before 1.0.0.78. plural NETGEAR A cross-site scripting vulnerability exists in the device.Information may be obtained and information may be tampered with", "sources": [ { "db": "NVD", "id": "CVE-2020-35807" }, { "db": "JVNDB", "id": "JVNDB-2020-014997" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-35807", "trust": 2.4 }, { "db": "JVNDB", "id": "JVNDB-2020-014997", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202012-1791", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-014997" }, { "db": "CNNVD", "id": "CNNVD-202012-1791" }, { "db": "NVD", "id": "CVE-2020-35807" } ] }, "id": "VAR-202012-1182", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.30766959083333334 }, "last_update_date": "2024-11-23T22:37:10.974000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Stored\u00a0Cross\u00a0Site\u00a0Scripting\u00a0on\u00a0Some\u00a0Routers\u00a0and\u00a0Orbi\u00a0WiFi\u00a0Systems,\u00a0PSV-2018-0557", "trust": 0.8, "url": "https://kb.netgear.com/000062730/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-and-Orbi-WiFi-Systems-PSV-2018-0557" }, { "title": "Certain NETGEAR devices Fixes for cross-site scripting vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=138160" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-014997" }, { "db": "CNNVD", "id": "CNNVD-202012-1791" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-79", "trust": 1.0 }, { "problemtype": "Cross-site scripting (CWE-79) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-014997" }, { "db": "NVD", "id": "CVE-2020-35807" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://kb.netgear.com/000062730/security-advisory-for-stored-cross-site-scripting-on-some-routers-and-orbi-wifi-systems-psv-2018-0557" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-35807" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-014997" }, { "db": "CNNVD", "id": "CNNVD-202012-1791" }, { "db": "NVD", "id": "CVE-2020-35807" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2020-014997" }, { "db": "CNNVD", "id": "CNNVD-202012-1791" }, { "db": "NVD", "id": "CVE-2020-35807" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-09-07T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-014997" }, { "date": "2020-12-29T00:00:00", "db": "CNNVD", "id": "CNNVD-202012-1791" }, { "date": "2020-12-30T00:15:14.800000", "db": "NVD", "id": "CVE-2020-35807" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-09-07T08:54:00", "db": "JVNDB", "id": "JVNDB-2020-014997" }, { "date": "2021-01-12T00:00:00", "db": "CNNVD", "id": "CNNVD-202012-1791" }, { "date": "2024-11-21T05:28:10.113000", "db": "NVD", "id": "CVE-2020-35807" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202012-1791" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Cross-site scripting vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-014997" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "XSS", "sources": [ { "db": "CNNVD", "id": "CNNVD-202012-1791" } ], "trust": 0.6 } }
var-202012-1198
Vulnerability from variot
Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.76, D6000 before 1.0.0.78, D6200 before 1.1.00.32, D7000 before 1.0.1.68, D7800 before 1.0.1.56, DM200 before 1.0.0.61, EX2700 before 1.0.1.52, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.74, EX6400 before 1.0.2.140, EX7300 before 1.0.2.140, EX8000 before 1.0.1.186, JR6150 before 1.0.1.18, PR2000 before 1.0.0.28, R6020 before 1.0.0.38, R6050 before 1.0.1.18, R6080 before 1.0.0.38, R6120 before 1.0.0.46, R6220 before 1.1.0.80, R6230 before 1.1.0.80, R6260 before 1.1.0.40, R6700v2 before 1.2.0.36, R6800 before 1.2.0.36, R6900v2 before 1.2.0.36, R7500v2 before 1.0.3.40, R7800 before 1.0.2.62, R8900 before 1.0.4.12, R9000 before 1.0.4.12, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK40 before 2.3.0.28, RBR40 before 2.3.0.28, RBS40 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, WN2000RPTv3 before 1.0.1.34, WN3000RPv2 before 1.0.0.78, WN3000RPv2 before 1.0.0.78, WN3000RPv3 before 1.0.2.78, WN3100RPv2 before 1.0.0.66, WNR2000v5 before 1.0.0.70, WNR2020 before 1.1.0.62, XR450 before 2.3.2.32, and XR500 before 2.3.2.32. plural NETGEAR The device contains an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202012-1198", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "r6260", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.0.40" }, { "model": "ex6200v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.74" }, { "model": "r9000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.12" }, { "model": "dm200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.61" }, { "model": "rbr50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.32" }, { "model": "r6050", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.18" }, { "model": "r6220", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.0.80" }, { "model": "d3600", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.76" }, { "model": "xr450", "scope": "eq", "trust": 1.0, "vendor": "netgear", "version": "2.3.2.32" }, { "model": "d7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.68" }, { "model": "rbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.28" }, { "model": "r6800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.36" }, { "model": "wn3000rpv2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.78" }, { "model": "rbk50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.32" }, { "model": "r6080", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.38" }, { "model": "ex6400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.140" }, { "model": "r6900v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.36" }, { "model": "r8900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.12" }, { "model": "wn3100rpv2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.66" }, { "model": "ex6150v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.76" }, { "model": "d6200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.00.32" }, { "model": "ex7300", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.140" }, { "model": "wnr2020", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.0.62" }, { "model": "ex2700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.52" }, { "model": "r6700v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.36" }, { "model": "wnr2000v5", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.70" }, { "model": "wn3000rpv3", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.78" }, { "model": "ex8000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.186" }, { "model": "jr6150", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.18" }, { "model": "rbk40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.28" }, { "model": "rbr20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.28" }, { "model": "pr2000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.28" }, { "model": "ex6100v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.76" }, { "model": "rbk20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.28" }, { "model": "rbs40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.28" }, { "model": "r6230", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.0.80" }, { "model": "r6120", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.46" }, { "model": "wn2000rptv3", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.34" }, { "model": "xr500", "scope": "eq", "trust": 1.0, "vendor": "netgear", "version": "2.3.2.32" }, { "model": "r6020", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.38" }, { "model": "d7800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.56" }, { "model": "d6000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.078" }, { "model": "r7800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.62" }, { "model": "r7500v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.40" }, { "model": "rbs50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.32" }, { "model": "rbs20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.28" }, { "model": "d6000", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex6150v2", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d7000", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex6200v2", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "dm200", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d7800", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex6100v2", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex2700", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d3600", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d6200", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015015" }, { "db": "NVD", "id": "CVE-2020-35799" } ] }, "cve": "CVE-2020-35799", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2020-35799", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2020-35799", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2020-35799", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2020-35799", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2020-35799", "trust": 1.0, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2020-35799", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2020-35799", "trust": 0.8, "value": "Critical" }, { "author": "CNNVD", "id": "CNNVD-202012-1741", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015015" }, { "db": "CNNVD", "id": "CNNVD-202012-1741" }, { "db": "NVD", "id": "CVE-2020-35799" }, { "db": "NVD", "id": "CVE-2020-35799" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.76, D6000 before 1.0.0.78, D6200 before 1.1.00.32, D7000 before 1.0.1.68, D7800 before 1.0.1.56, DM200 before 1.0.0.61, EX2700 before 1.0.1.52, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.74, EX6400 before 1.0.2.140, EX7300 before 1.0.2.140, EX8000 before 1.0.1.186, JR6150 before 1.0.1.18, PR2000 before 1.0.0.28, R6020 before 1.0.0.38, R6050 before 1.0.1.18, R6080 before 1.0.0.38, R6120 before 1.0.0.46, R6220 before 1.1.0.80, R6230 before 1.1.0.80, R6260 before 1.1.0.40, R6700v2 before 1.2.0.36, R6800 before 1.2.0.36, R6900v2 before 1.2.0.36, R7500v2 before 1.0.3.40, R7800 before 1.0.2.62, R8900 before 1.0.4.12, R9000 before 1.0.4.12, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK40 before 2.3.0.28, RBR40 before 2.3.0.28, RBS40 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, WN2000RPTv3 before 1.0.1.34, WN3000RPv2 before 1.0.0.78, WN3000RPv2 before 1.0.0.78, WN3000RPv3 before 1.0.2.78, WN3100RPv2 before 1.0.0.66, WNR2000v5 before 1.0.0.70, WNR2020 before 1.1.0.62, XR450 before 2.3.2.32, and XR500 before 2.3.2.32. plural NETGEAR The device contains an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state", "sources": [ { "db": "NVD", "id": "CVE-2020-35799" }, { "db": "JVNDB", "id": "JVNDB-2020-015015" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-35799", "trust": 2.4 }, { "db": "JVNDB", "id": "JVNDB-2020-015015", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202012-1741", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015015" }, { "db": "CNNVD", "id": "CNNVD-202012-1741" }, { "db": "NVD", "id": "CVE-2020-35799" } ] }, "id": "VAR-202012-1198", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.447916488139535 }, "last_update_date": "2024-11-23T22:58:05.562000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Stack\u00a0Overflow\u00a0on\u00a0Some\u00a0Routers,\u00a0Range\u00a0Extenders,\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2018-0296", "trust": 0.8, "url": "https://kb.netgear.com/000062709/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-Range-Extenders-and-WiFi-Systems-PSV-2018-0296" }, { "title": "Certain NETGEAR devices Buffer error vulnerability fix", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=138121" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015015" }, { "db": "CNNVD", "id": "CNNVD-202012-1741" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015015" }, { "db": "NVD", "id": "CVE-2020-35799" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://kb.netgear.com/000062709/security-advisory-for-pre-authentication-stack-overflow-on-some-routers-range-extenders-and-wifi-systems-psv-2018-0296" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-35799" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015015" }, { "db": "CNNVD", "id": "CNNVD-202012-1741" }, { "db": "NVD", "id": "CVE-2020-35799" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2020-015015" }, { "db": "CNNVD", "id": "CNNVD-202012-1741" }, { "db": "NVD", "id": "CVE-2020-35799" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-09-07T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-015015" }, { "date": "2020-12-29T00:00:00", "db": "CNNVD", "id": "CNNVD-202012-1741" }, { "date": "2020-12-30T00:15:14.347000", "db": "NVD", "id": "CVE-2020-35799" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-09-07T09:06:00", "db": "JVNDB", "id": "JVNDB-2020-015015" }, { "date": "2021-01-12T00:00:00", "db": "CNNVD", "id": "CNNVD-202012-1741" }, { "date": "2024-11-21T05:28:08.360000", "db": "NVD", "id": "CVE-2020-35799" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202012-1741" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Out-of-bounds write vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015015" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202012-1741" } ], "trust": 0.6 } }
var-202004-0776
Vulnerability from variot
Certain NETGEAR devices are affected by stored XSS. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D7800 before 1.0.1.44, DM200 before 1.0.0.58, R7500v2 before 1.0.3.40, R7800 before 1.0.2.60, R8900 before 1.0.4.12, R9000 before 1.0.4.12, RBK20 before 2.3.0.22, RBR20 before 2.3.0.22, RBS20 before 2.3.0.22, RBK50 before 2.3.0.22, RBR50 before 2.3.0.22, RBS50 before 2.3.0.22, RBS40 before 2.3.0.22, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.60, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, and WNR2000v5 before 1.0.0.68. plural NETGEAR A cross-site scripting vulnerability exists in the device.Information may be obtained and tampered with. NETGEAR D3600, etc. are all products of NETGEAR. NETGEAR D3600 is a wireless modem. NETGEAR R7500 is a wireless router. NETGEAR DM200 is a wireless modem. The vulnerability stems from the lack of proper verification of client data by WEB applications. Attackers can use this vulnerability to execute client code
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202004-0776", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "r7800", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.2.60" }, { "model": "r8900", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.4.12" }, { "model": "r9000", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.4.12" }, { "model": "d7800", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.1.44" }, { "model": "d3600", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.0.75" }, { "model": "d6000", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.0.75" }, { "model": "dm200", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.0.58" }, { "model": "rbk20", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "2.3.0.22" }, { "model": "rbr20", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "2.3.0.22" }, { "model": "rbs20", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "2.3.0.22" }, { "model": "rbk50", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "2.3.0.22" }, { "model": "rbr50", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "2.3.0.22" }, { "model": "rbs50", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "2.3.0.22" }, { "model": "rbs40", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "2.3.0.22" }, { "model": "wn3100rp", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.60" }, { "model": "r7500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.40" }, { "model": "wndr4500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.58" }, { "model": "wnr2000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.68" }, { "model": "wn3000rp", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.70" }, { "model": "wn3000rp", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.68" }, { "model": "wndr4300", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.58" }, { "model": "d3600", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.0.75" }, { "model": "d6000", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.0.75" }, { "model": "d7800", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.1.44" }, { "model": "dm200", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.0.58" }, { "model": "r7500", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.3.34" }, { "model": "r7800", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.2.60" }, { "model": "r8900", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.4.12" }, { "model": "r9000", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.4.12" }, { "model": "rbk20", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "2.3.0.22" }, { "model": "rbr20", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "2.3.0.22" }, { "model": "wn3000rpv3", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.2.70" }, { "model": "wn3000rpv2", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.0.68" }, { "model": "wn3100rpv2", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.0.60" }, { "model": "wndr4300v2", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.0.58" }, { "model": "wndr4500v3", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.0.58" }, { "model": "r7500v2", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.3.40" }, { "model": "wnr2000v5", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.0.68" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-30685" }, { "db": "JVNDB", "id": "JVNDB-2019-015414" }, { "db": "NVD", "id": "CVE-2019-20714" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:netgear:d3600_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:d6000_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:d7800_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:dm200_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:r7500_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:r7800_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:r8900_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:r9000_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk20_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr20_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-015414" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Wayne Low of Fortinets FortiGuard Labs", "sources": [ { "db": "CNNVD", "id": "CNNVD-202004-1298" } ], "trust": 0.6 }, "cve": "CVE-2019-20714", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 3.5, "confidentialityImpact": "NONE", "exploitabilityScore": 6.8, "id": "CVE-2019-20714", "impactScore": 2.9, "integrityImpact": "PARTIAL", "severity": "LOW", "trust": 1.0, "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Medium", "accessVector": "Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "None", "baseScore": 3.5, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2019-015414", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 3.5, "confidentialityImpact": "NONE", "exploitabilityScore": 6.8, "id": "CNVD-2020-30685", "impactScore": 2.9, "integrityImpact": "PARTIAL", "severity": "LOW", "trust": 0.6, "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 1.7, "id": "CVE-2019-20714", "impactScore": 2.7, "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "cve@mitre.org", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 1.7, "id": "CVE-2019-20714", "impactScore": 2.7, "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 4.8, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "JVNDB-2019-015414", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "High", "scope": "Changed", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2019-20714", "trust": 1.0, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2019-20714", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "JVNDB-2019-015414", "trust": 0.8, "value": "Medium" }, { "author": "CNVD", "id": "CNVD-2020-30685", "trust": 0.6, "value": "LOW" }, { "author": "CNNVD", "id": "CNNVD-202004-1298", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-30685" }, { "db": "JVNDB", "id": "JVNDB-2019-015414" }, { "db": "CNNVD", "id": "CNNVD-202004-1298" }, { "db": "NVD", "id": "CVE-2019-20714" }, { "db": "NVD", "id": "CVE-2019-20714" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by stored XSS. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D7800 before 1.0.1.44, DM200 before 1.0.0.58, R7500v2 before 1.0.3.40, R7800 before 1.0.2.60, R8900 before 1.0.4.12, R9000 before 1.0.4.12, RBK20 before 2.3.0.22, RBR20 before 2.3.0.22, RBS20 before 2.3.0.22, RBK50 before 2.3.0.22, RBR50 before 2.3.0.22, RBS50 before 2.3.0.22, RBS40 before 2.3.0.22, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.60, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, and WNR2000v5 before 1.0.0.68. plural NETGEAR A cross-site scripting vulnerability exists in the device.Information may be obtained and tampered with. NETGEAR D3600, etc. are all products of NETGEAR. NETGEAR D3600 is a wireless modem. NETGEAR R7500 is a wireless router. NETGEAR DM200 is a wireless modem. The vulnerability stems from the lack of proper verification of client data by WEB applications. Attackers can use this vulnerability to execute client code", "sources": [ { "db": "NVD", "id": "CVE-2019-20714" }, { "db": "JVNDB", "id": "JVNDB-2019-015414" }, { "db": "CNVD", "id": "CNVD-2020-30685" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2019-20714", "trust": 3.0 }, { "db": "JVNDB", "id": "JVNDB-2019-015414", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2020-30685", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202004-1298", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-30685" }, { "db": "JVNDB", "id": "JVNDB-2019-015414" }, { "db": "CNNVD", "id": "CNNVD-202004-1298" }, { "db": "NVD", "id": "CVE-2019-20714" } ] }, "id": "VAR-202004-0776", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2020-30685" } ], "trust": 1.1352816739130436 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-30685" } ] }, "last_update_date": "2024-11-23T22:37:25.538000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Stored Cross Site Scripting on Some Routers, Gateways, and WiFi System, PSV-2018-0249", "trust": 0.8, "url": "https://kb.netgear.com/000061214/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Gateways-and-WiFi-System-PSV-2018-0249" }, { "title": "Patch for Multiple NETGEAR product cross-site scripting vulnerabilities (CNVD-2020-30685)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/219487" }, { "title": "Multiple NETGEAR Fixes for product cross-site scripting vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=116567" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-30685" }, { "db": "JVNDB", "id": "JVNDB-2019-015414" }, { "db": "CNNVD", "id": "CNNVD-202004-1298" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-79", "trust": 1.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-015414" }, { "db": "NVD", "id": "CVE-2019-20714" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-20714" }, { "trust": 1.6, "url": "https://kb.netgear.com/000061214/security-advisory-for-stored-cross-site-scripting-on-some-routers-gateways-and-wifi-system-psv-2018-0249" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-20714" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-30685" }, { "db": "JVNDB", "id": "JVNDB-2019-015414" }, { "db": "CNNVD", "id": "CNNVD-202004-1298" }, { "db": "NVD", "id": "CVE-2019-20714" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2020-30685" }, { "db": "JVNDB", "id": "JVNDB-2019-015414" }, { "db": "CNNVD", "id": "CNNVD-202004-1298" }, { "db": "NVD", "id": "CVE-2019-20714" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-05-29T00:00:00", "db": "CNVD", "id": "CNVD-2020-30685" }, { "date": "2020-05-19T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-015414" }, { "date": "2020-04-16T00:00:00", "db": "CNNVD", "id": "CNNVD-202004-1298" }, { "date": "2020-04-16T19:15:24.777000", "db": "NVD", "id": "CVE-2019-20714" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-05-29T00:00:00", "db": "CNVD", "id": "CNVD-2020-30685" }, { "date": "2020-05-19T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-015414" }, { "date": "2020-04-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202004-1298" }, { "date": "2024-11-21T04:39:09.837000", "db": "NVD", "id": "CVE-2019-20714" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202004-1298" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR Cross-site scripting vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-015414" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "XSS", "sources": [ { "db": "CNNVD", "id": "CNNVD-202004-1298" } ], "trust": 0.6 } }
var-202112-2308
Vulnerability from variot
Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D3600 before 1.0.0.72, D6000 before 1.0.0.72, D6200 before 1.1.00.34, D6220 before 1.0.0.52, D6400 before 1.0.0.86, D7000 before 1.0.1.74, D7000v2 before 1.0.0.53, D7800 before 1.0.1.56, D8500 before 1.0.3.44, DC112A before 1.0.0.42, DGN2200Bv4 before 1.0.0.109, DGN2200v4 before 1.0.0.110, DM200 before 1.0.0.61, EX3700 before 1.0.0.76, EX3800 before 1.0.0.76, EX6120 before 1.0.0.46, EX6130 before 1.0.0.28, EX7000 before 1.0.1.78, PR2000 before 1.0.0.28, R6220 before 1.1.0.100, R6230 before 1.1.0.100, R6250 before 1.0.4.34, R6300v2 before 1.0.4.34, R6400 before 1.0.1.46, R6400v2 before 1.0.2.66, R6700v3 before 1.0.2.66, R6700 before 1.0.2.6, R6900 before 1.0.2.6, R7000 before 1.0.9.34, R7100LG before 1.0.0.50, R7500v2 before 1.0.3.40, R7900P before 1.4.1.50, R8000P before 1.4.1.50, R8900 before 1.0.4.12, R9000 before 1.0.4.12, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK40 before 2.3.0.28, RBR40 before 2.3.0.28, RBS40 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, WN3000RPv2 before 1.0.0.78, WNDR3400v3 before 1.0.1.24, WNR2000v5 before 1.0.0.70, WNR2020 before 1.1.0.62, and XR500 before 2.3.2.56. plural NETGEAR There is an unspecified vulnerability in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects D3600 prior to 1.0.0.72, D6000 prior to 1.0.0.72, D6200 prior to 1.1.00.34, D6220 prior to 1.0.0.52, D6400 prior to 1.0.0.86, D7000 prior to 1.0.1.74, D7000v2 prior to 1.0.0.53, D7800 prior to 1.0.1.56, D8500 prior to 1.0.3.44, DC112A prior to 1.0.0.42, DGN2200Bv4 prior to 1.0.0.109, DGN2200v4 prior to 1.0.0.110, DM200 prior to 1.0.0.61, EX3700 prior to 1.0.0.76, EX3800 prior to 1.0.0.76, EX6120 prior to 1.0.0.46, EX6130 prior to 1.0.0.28, EX7000 prior to 1.0.1.78, PR2000 prior to 1.0.0.28, R6220 prior to 1.1.0.100, R6230 prior to 1.1.0.100, R6250 prior to 1.0.4.34, R6300v2 prior to 1.0.4.34, R6400 prior to 1.0.1.46, R6400v2 prior to 1.0.2.66, R6700v3 prior to 1.0.2.66, R6700 prior to 1.0.2.6, R6900 prior to 1.0.2.6, R7000 prior to 1.0.9.34, R7100LG prior to 1.0.0.50, R7500v2 prior to 1.0.3.40, R7900P prior to 1.4.1.50, R8000P prior to 1.4.1.50, R8900 prior to 1.0.4.12, R9000 prior to 1.0.4.12, RBK20 prior to 2.3.0.28, RBR20 prior to 2.3.0.28, RBS20 prior to 2.3.0.28, RBK40 prior to 2.3.0.28, RBR40 prior to 2.3.0.28, RBS40 prior to 2.3.0.28, RBK50 prior to 2.3.0.32, RBR50 prior to 2.3.0.32, RBS50 prior to 2.3.0.32, WN3000RPv2 prior to 1.0.0.78, WNDR3400v3 prior to 1.0.1.24, WNR2000v5 prior to 1.0.0.70, WNR2020 prior to 1.1.0.62, and XR500 prior to 2.3.2.56
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2308", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ex3800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.76" }, { "model": "dc112a", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.42" }, { "model": "r9000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.12" }, { "model": "rbr20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.28" }, { "model": "d6000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.72" }, { "model": "pr2000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.28" }, { "model": "r6400v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.66" }, { "model": "wn3000rpv2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.78" }, { "model": "d6200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.00.34" }, { "model": "wnr2020", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.0.62" }, { "model": "ex7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.78" }, { "model": "dm200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.61" }, { "model": "d3600", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.72" }, { "model": "dgn2200bv4", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.109" }, { "model": "r8000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.50" }, { "model": "rbk40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.28" }, { "model": "rbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.28" }, { "model": "rbk20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.28" }, { "model": "r7900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.50" }, { "model": "rbs20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.28" }, { "model": "dgn2200v4", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.110" }, { "model": "r7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.9.34" }, { "model": "ex3700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.76" }, { "model": "d6220", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.52" }, { "model": "d7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.74" }, { "model": "xr500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.2.56" }, { "model": "r6900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.6" }, { "model": "r6300v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.34" }, { "model": "r6220", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.0.100" }, { "model": "r7500v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.40" }, { "model": "ex6130", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.28" }, { "model": "r6250", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.34" }, { "model": "r8900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.12" }, { "model": "rbs40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.28" }, { "model": "wndr3400v3", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.24" }, { "model": "wnr2000v5", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.70" }, { "model": "rbs50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.32" }, { "model": "d7800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.56" }, { "model": "rbk50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.32" }, { "model": "r6700v3", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.66" }, { "model": "ex6120", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.46" }, { "model": "r6700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.6" }, { "model": "d8500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.44" }, { "model": "r7100lg", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.50" }, { "model": "d7000v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.53" }, { "model": "r6400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.46" }, { "model": "d6400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.86" }, { "model": "r6230", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.0.100" }, { "model": "rbr50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.32" }, { "model": "d8500", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d6200", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d7800", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d7000", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d3600", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "dc112a", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d6400", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d7000v2", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d6000", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d6220", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017513" }, { "db": "NVD", "id": "CVE-2021-45641" } ] }, "cve": "CVE-2021-45641", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "id": "CVE-2021-45641", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2021-45641", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "cve@mitre.org", "availabilityImpact": "NONE", "baseScore": 4.6, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 2.1, "id": "CVE-2021-45641", "impactScore": 2.5, "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45641", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-45641", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-45641", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "CVE-2021-45641", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-202112-2437", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017513" }, { "db": "CNNVD", "id": "CNNVD-202112-2437" }, { "db": "NVD", "id": "CVE-2021-45641" }, { "db": "NVD", "id": "CVE-2021-45641" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D3600 before 1.0.0.72, D6000 before 1.0.0.72, D6200 before 1.1.00.34, D6220 before 1.0.0.52, D6400 before 1.0.0.86, D7000 before 1.0.1.74, D7000v2 before 1.0.0.53, D7800 before 1.0.1.56, D8500 before 1.0.3.44, DC112A before 1.0.0.42, DGN2200Bv4 before 1.0.0.109, DGN2200v4 before 1.0.0.110, DM200 before 1.0.0.61, EX3700 before 1.0.0.76, EX3800 before 1.0.0.76, EX6120 before 1.0.0.46, EX6130 before 1.0.0.28, EX7000 before 1.0.1.78, PR2000 before 1.0.0.28, R6220 before 1.1.0.100, R6230 before 1.1.0.100, R6250 before 1.0.4.34, R6300v2 before 1.0.4.34, R6400 before 1.0.1.46, R6400v2 before 1.0.2.66, R6700v3 before 1.0.2.66, R6700 before 1.0.2.6, R6900 before 1.0.2.6, R7000 before 1.0.9.34, R7100LG before 1.0.0.50, R7500v2 before 1.0.3.40, R7900P before 1.4.1.50, R8000P before 1.4.1.50, R8900 before 1.0.4.12, R9000 before 1.0.4.12, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK40 before 2.3.0.28, RBR40 before 2.3.0.28, RBS40 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, WN3000RPv2 before 1.0.0.78, WNDR3400v3 before 1.0.1.24, WNR2000v5 before 1.0.0.70, WNR2020 before 1.1.0.62, and XR500 before 2.3.2.56. plural NETGEAR There is an unspecified vulnerability in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects D3600 prior to 1.0.0.72, D6000 prior to 1.0.0.72, D6200 prior to 1.1.00.34, D6220 prior to 1.0.0.52, D6400 prior to 1.0.0.86, D7000 prior to 1.0.1.74, D7000v2 prior to 1.0.0.53, D7800 prior to 1.0.1.56, D8500 prior to 1.0.3.44, DC112A prior to 1.0.0.42, DGN2200Bv4 prior to 1.0.0.109, DGN2200v4 prior to 1.0.0.110, DM200 prior to 1.0.0.61, EX3700 prior to 1.0.0.76, EX3800 prior to 1.0.0.76, EX6120 prior to 1.0.0.46, EX6130 prior to 1.0.0.28, EX7000 prior to 1.0.1.78, PR2000 prior to 1.0.0.28, R6220 prior to 1.1.0.100, R6230 prior to 1.1.0.100, R6250 prior to 1.0.4.34, R6300v2 prior to 1.0.4.34, R6400 prior to 1.0.1.46, R6400v2 prior to 1.0.2.66, R6700v3 prior to 1.0.2.66, R6700 prior to 1.0.2.6, R6900 prior to 1.0.2.6, R7000 prior to 1.0.9.34, R7100LG prior to 1.0.0.50, R7500v2 prior to 1.0.3.40, R7900P prior to 1.4.1.50, R8000P prior to 1.4.1.50, R8900 prior to 1.0.4.12, R9000 prior to 1.0.4.12, RBK20 prior to 2.3.0.28, RBR20 prior to 2.3.0.28, RBS20 prior to 2.3.0.28, RBK40 prior to 2.3.0.28, RBR40 prior to 2.3.0.28, RBS40 prior to 2.3.0.28, RBK50 prior to 2.3.0.32, RBR50 prior to 2.3.0.32, RBS50 prior to 2.3.0.32, WN3000RPv2 prior to 1.0.0.78, WNDR3400v3 prior to 1.0.1.24, WNR2000v5 prior to 1.0.0.70, WNR2020 prior to 1.1.0.62, and XR500 prior to 2.3.2.56", "sources": [ { "db": "NVD", "id": "CVE-2021-45641" }, { "db": "JVNDB", "id": "JVNDB-2021-017513" }, { "db": "VULMON", "id": "CVE-2021-45641" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45641", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017513", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2437", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45641", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45641" }, { "db": "JVNDB", "id": "JVNDB-2021-017513" }, { "db": "CNNVD", "id": "CNNVD-202112-2437" }, { "db": "NVD", "id": "CVE-2021-45641" } ] }, "id": "VAR-202112-2308", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.42809713404255323 }, "last_update_date": "2024-11-23T22:44:07.304000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Security\u00a0Misconfiguration\u00a0on\u00a0Some\u00a0Routers,\u00a0Extenders,\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2018-0624", "trust": 0.8, "url": "https://kb.netgear.com/000064053/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2018-0624" }, { "title": "Netgear NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=176675" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017513" }, { "db": "CNNVD", "id": "CNNVD-202112-2437" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017513" }, { "db": "NVD", "id": "CVE-2021-45641" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064053/security-advisory-for-security-misconfiguration-on-some-routers-extenders-and-wifi-systems-psv-2018-0624" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45641" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45641" }, { "db": "JVNDB", "id": "JVNDB-2021-017513" }, { "db": "CNNVD", "id": "CNNVD-202112-2437" }, { "db": "NVD", "id": "CVE-2021-45641" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45641" }, { "db": "JVNDB", "id": "JVNDB-2021-017513" }, { "db": "CNNVD", "id": "CNNVD-202112-2437" }, { "db": "NVD", "id": "CVE-2021-45641" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45641" }, { "date": "2023-01-24T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017513" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2437" }, { "date": "2021-12-26T01:15:19.690000", "db": "NVD", "id": "CVE-2021-45641" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-27T00:00:00", "db": "VULMON", "id": "CVE-2021-45641" }, { "date": "2023-01-24T05:20:00", "db": "JVNDB", "id": "JVNDB-2021-017513" }, { "date": "2022-01-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2437" }, { "date": "2024-11-21T06:32:45.310000", "db": "NVD", "id": "CVE-2021-45641" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2437" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017513" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2437" } ], "trust": 0.6 } }
var-202004-1550
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.44, EX6150v2 before 1.0.1.70, EX6100v2 before 1.0.1.70, EX6200v2 before 1.0.1.64, EX7300 before 1.0.2.136, EX6400 before 1.0.2.136, R6100 before 1.0.1.16, R7500 before 1.0.0.110, R7800 before 1.0.2.32, R9000 before 1.0.4.12, WN3000RPv2 before 1.0.0.56, WN3000RPv3 before 1.0.2.52, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50. plural NETGEAR A device contains an injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR R7800, etc. are all products of NETGEAR. NETGEAR R7800 is a wireless router. NETGEAR D7800 is a wireless modem. NETGEAR WNDR4300 is a wireless router.
There are injection vulnerabilities in many NETGEAR products, which can be exploited by an attacker to cause the system or product to produce an incorrect interpretation or interpretation method
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202004-1550", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "r9000", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.4.12" }, { "model": "r6100", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.1.16" }, { "model": "d7800", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.1.44" }, { "model": "ex7300", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.2.136" }, { "model": "ex6400", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.2.136" }, { "model": "r7500", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.0.110" }, { "model": "r7800", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.2.32" }, { "model": "ex6200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.64" }, { "model": "wndr4500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.50" }, { "model": "wndr4300", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.50" }, { "model": "ex6150", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.70" }, { "model": "wn3000rp", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.56" }, { "model": "wn3000rp", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.52" }, { "model": "ex6100", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.70" }, { "model": "d7800", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.1.44" }, { "model": "ex6100", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.1.70" }, { "model": "ex6150", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.1.70" }, { "model": "ex6200", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.1.64" }, { "model": "ex6400", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.2.136" }, { "model": "ex7300", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.2.136" }, { "model": "r6100", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.1.16" }, { "model": "r7500", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.0.110" }, { "model": "r7800", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.2.32" }, { "model": "r9000", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.4.12" }, { "model": "wndr4300v2", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.0.50" }, { "model": "wndr4500v3", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.0.50" }, { "model": "wn3000rpv3", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.2.52" }, { "model": "ex6150v2", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.1.70" }, { "model": "ex6100v2", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.1.70" }, { "model": "ex6200v2", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.1.64" }, { "model": "wn3000rpv2", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.0.56" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-31331" }, { "db": "JVNDB", "id": "JVNDB-2018-016298" }, { "db": "NVD", "id": "CVE-2018-21114" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:netgear:d7800_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:ex6100_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:ex6150_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:ex6200_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:ex6400_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:ex7300_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:r6100_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:r7500_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:r7800_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:r9000_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-016298" } ] }, "cve": "CVE-2018-21114", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "id": "CVE-2018-21114", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.0, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2018-016298", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "id": "CNVD-2020-31331", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "id": "CVE-2018-21114", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "id": "CVE-2018-21114", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2018-016298", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2018-21114", "trust": 1.0, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2018-21114", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "JVNDB-2018-016298", "trust": 0.8, "value": "Medium" }, { "author": "CNVD", "id": "CNVD-2020-31331", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202004-1898", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-31331" }, { "db": "JVNDB", "id": "JVNDB-2018-016298" }, { "db": "CNNVD", "id": "CNNVD-202004-1898" }, { "db": "NVD", "id": "CVE-2018-21114" }, { "db": "NVD", "id": "CVE-2018-21114" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.44, EX6150v2 before 1.0.1.70, EX6100v2 before 1.0.1.70, EX6200v2 before 1.0.1.64, EX7300 before 1.0.2.136, EX6400 before 1.0.2.136, R6100 before 1.0.1.16, R7500 before 1.0.0.110, R7800 before 1.0.2.32, R9000 before 1.0.4.12, WN3000RPv2 before 1.0.0.56, WN3000RPv3 before 1.0.2.52, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50. plural NETGEAR A device contains an injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR R7800, etc. are all products of NETGEAR. NETGEAR R7800 is a wireless router. NETGEAR D7800 is a wireless modem. NETGEAR WNDR4300 is a wireless router. \n\r\n\r\nThere are injection vulnerabilities in many NETGEAR products, which can be exploited by an attacker to cause the system or product to produce an incorrect interpretation or interpretation method", "sources": [ { "db": "NVD", "id": "CVE-2018-21114" }, { "db": "JVNDB", "id": "JVNDB-2018-016298" }, { "db": "CNVD", "id": "CNVD-2020-31331" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2018-21114", "trust": 3.0 }, { "db": "JVNDB", "id": "JVNDB-2018-016298", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2020-31331", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202004-1898", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-31331" }, { "db": "JVNDB", "id": "JVNDB-2018-016298" }, { "db": "CNNVD", "id": "CNNVD-202004-1898" }, { "db": "NVD", "id": "CVE-2018-21114" } ] }, "id": "VAR-202004-1550", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2020-31331" } ], "trust": 1.199431995625 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-31331" } ] }, "last_update_date": "2024-11-23T22:25:32.412000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Post-Authentication Command Injection on Some Routers, Modem Routers, and Wireless Extenders, PSV-2017-0645", "trust": 0.8, "url": "https://kb.netgear.com/000060437/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Modem-Routers-and-Wireless-Extenders-PSV-2017-0645" }, { "title": "Patch for Multiple NETGEAR product injection vulnerabilities (CNVD-2020-31331)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/219995" }, { "title": "Multiple NETGEAR Fixing measures for product injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=117242" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-31331" }, { "db": "JVNDB", "id": "JVNDB-2018-016298" }, { "db": "CNNVD", "id": "CNNVD-202004-1898" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-74", "trust": 1.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-016298" }, { "db": "NVD", "id": "CVE-2018-21114" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-21114" }, { "trust": 1.6, "url": "https://kb.netgear.com/000060437/security-advisory-for-post-authentication-command-injection-on-some-routers-modem-routers-and-wireless-extenders-psv-2017-0645" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-21114" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-31331" }, { "db": "JVNDB", "id": "JVNDB-2018-016298" }, { "db": "CNNVD", "id": "CNNVD-202004-1898" }, { "db": "NVD", "id": "CVE-2018-21114" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2020-31331" }, { "db": "JVNDB", "id": "JVNDB-2018-016298" }, { "db": "CNNVD", "id": "CNNVD-202004-1898" }, { "db": "NVD", "id": "CVE-2018-21114" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-03T00:00:00", "db": "CNVD", "id": "CNVD-2020-31331" }, { "date": "2020-05-21T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-016298" }, { "date": "2020-04-22T00:00:00", "db": "CNNVD", "id": "CNNVD-202004-1898" }, { "date": "2020-04-22T15:15:13.537000", "db": "NVD", "id": "CVE-2018-21114" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-03T00:00:00", "db": "CNVD", "id": "CNVD-2020-31331" }, { "date": "2020-05-21T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-016298" }, { "date": "2020-04-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202004-1898" }, { "date": "2024-11-21T04:02:56.130000", "db": "NVD", "id": "CVE-2018-21114" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202004-1898" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR Injection vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-016298" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202004-1898" } ], "trust": 0.6 } }
var-202004-0797
Vulnerability from variot
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.60, DM200 before 1.0.0.61, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX8000 before 1.0.1.180, R7800 before 1.0.2.52, R8900 before 1.0.4.26, R9000 before 1.0.4.26, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.66, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, and WNR2000v5 before 1.0.0.68. plural NETGEAR The device is vulnerable to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR R8900, etc. are all wireless routers from NETGEAR. The vulnerability stems from the fact that when the network system or product performs operations on the memory, the data boundary is not correctly verified, resulting in incorrect read and write operations to other associated memory locations. Attackers can use this vulnerability to cause buffer overflow or heap overflow, etc
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202004-0797", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "r7800", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.2.52" }, { "model": "r9000", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.4.26" }, { "model": "ex8000", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.1.180" }, { "model": "dm200", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.0.61" }, { "model": "d6100", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.0.60" }, { "model": "r8900", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.4.26" }, { "model": "ex2700", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.1.48" }, { "model": "wnr2000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.68" }, { "model": "wn3000rp", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.70" }, { "model": "ex6150", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.76" }, { "model": "ex6200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.72" }, { "model": "ex6100", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.76" }, { "model": "wn3000rp", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.68" }, { "model": "wndr4300", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.58" }, { "model": "wn2000rpt", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.32" }, { "model": "wndr4500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.58" }, { "model": "wn3100rp", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.66" }, { "model": "d6100", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.0.60" }, { "model": "dm200", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.0.61" }, { "model": "ex2700", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.1.48" }, { "model": "ex6100", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.1.76" }, { "model": "ex6150", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.1.76" }, { "model": "ex6200", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.1.72" }, { "model": "ex8000", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.1.180" }, { "model": "r7800", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.2.52" }, { "model": "r8900", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.4.26" }, { "model": "r9000", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.4.26" }, { "model": "ex6100v2", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.1.76" }, { "model": "ex6150v2", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.1.76" }, { "model": "wn2000rptv3", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.1.32" }, { "model": "wn3000rpv3", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.2.70" }, { "model": "wn3100rpv2", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.0.66" }, { "model": "wn3000rpv2", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.0.68" }, { "model": "wndr4300v2", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.0.58" }, { "model": "wndr4500v3", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.0.58" }, { "model": "wnr2000v5", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.0.68" }, { "model": "ex6200v2", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.1.72" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-66985" }, { "db": "JVNDB", "id": "JVNDB-2019-015366" }, { "db": "NVD", "id": "CVE-2019-20751" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:netgear:d6100_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:dm200_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:ex2700_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:ex6100_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:ex6150_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:ex6200_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:ex8000_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:r7800_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:r8900_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:r9000_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-015366" } ] }, "cve": "CVE-2019-20751", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "id": "CVE-2019-20751", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.0, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2019-015366", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "id": "CNVD-2021-66985", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "id": "CVE-2019-20751", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "id": "CVE-2019-20751", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2019-015366", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2019-20751", "trust": 1.0, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2019-20751", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "JVNDB-2019-015366", "trust": 0.8, "value": "Medium" }, { "author": "CNVD", "id": "CNVD-2021-66985", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202004-1362", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-66985" }, { "db": "JVNDB", "id": "JVNDB-2019-015366" }, { "db": "CNNVD", "id": "CNNVD-202004-1362" }, { "db": "NVD", "id": "CVE-2019-20751" }, { "db": "NVD", "id": "CVE-2019-20751" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.60, DM200 before 1.0.0.61, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX8000 before 1.0.1.180, R7800 before 1.0.2.52, R8900 before 1.0.4.26, R9000 before 1.0.4.26, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.66, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, and WNR2000v5 before 1.0.0.68. plural NETGEAR The device is vulnerable to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR R8900, etc. are all wireless routers from NETGEAR. The vulnerability stems from the fact that when the network system or product performs operations on the memory, the data boundary is not correctly verified, resulting in incorrect read and write operations to other associated memory locations. Attackers can use this vulnerability to cause buffer overflow or heap overflow, etc", "sources": [ { "db": "NVD", "id": "CVE-2019-20751" }, { "db": "JVNDB", "id": "JVNDB-2019-015366" }, { "db": "CNVD", "id": "CNVD-2021-66985" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2019-20751", "trust": 3.0 }, { "db": "JVNDB", "id": "JVNDB-2019-015366", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-66985", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202004-1362", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-66985" }, { "db": "JVNDB", "id": "JVNDB-2019-015366" }, { "db": "CNNVD", "id": "CNNVD-202004-1362" }, { "db": "NVD", "id": "CVE-2019-20751" } ] }, "id": "VAR-202004-0797", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-66985" } ], "trust": 1.2212749289999998 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-66985" } ] }, "last_update_date": "2024-11-23T22:37:25.511000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Post-Authentication Stack Overflow on Some Extenders, Gateways, and Routers, PSV-2018-0171", "trust": 0.8, "url": "https://kb.netgear.com/000060964/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Extenders-Gateways-and-Routers-PSV-2018-0171" }, { "title": "Patch for Buffer overflow vulnerabilities in multiple NETGEAR products (CNVD-2021-66985)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/288721" }, { "title": "Multiple NETGEAR Product Buffer Error Vulnerability Fix", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=115006" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-66985" }, { "db": "JVNDB", "id": "JVNDB-2019-015366" }, { "db": "CNNVD", "id": "CNNVD-202004-1362" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-015366" }, { "db": "NVD", "id": "CVE-2019-20751" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-20751" }, { "trust": 1.6, "url": "https://kb.netgear.com/000060964/security-advisory-for-post-authentication-stack-overflow-on-some-extenders-gateways-and-routers-psv-2018-0171" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-20751" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-66985" }, { "db": "JVNDB", "id": "JVNDB-2019-015366" }, { "db": "CNNVD", "id": "CNNVD-202004-1362" }, { "db": "NVD", "id": "CVE-2019-20751" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-66985" }, { "db": "JVNDB", "id": "JVNDB-2019-015366" }, { "db": "CNNVD", "id": "CNNVD-202004-1362" }, { "db": "NVD", "id": "CVE-2019-20751" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-08-31T00:00:00", "db": "CNVD", "id": "CNVD-2021-66985" }, { "date": "2020-05-14T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-015366" }, { "date": "2020-04-16T00:00:00", "db": "CNNVD", "id": "CNNVD-202004-1362" }, { "date": "2020-04-16T21:15:13.067000", "db": "NVD", "id": "CVE-2019-20751" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-08-31T00:00:00", "db": "CNVD", "id": "CNVD-2021-66985" }, { "date": "2020-05-14T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-015366" }, { "date": "2020-04-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202004-1362" }, { "date": "2024-11-21T04:39:16.010000", "db": "NVD", "id": "CVE-2019-20751" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202004-1362" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR Out-of-bounds write vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-015366" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202004-1362" } ], "trust": 0.6 } }
var-202004-0779
Vulnerability from variot
Certain NETGEAR devices are affected by denial of service. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D7800 before 1.0.1.44, EX2700 before 1.0.1.52, EX6200v2 before 1.0.1.74, EX8000 before 1.0.1.180, R7500v2 before 1.0.3.38, R7800 before 1.0.2.58, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, RBS40 before 2.3.0.28, SRK60 before 2.2.1.210, SRR60 before 2.2.1.210, SRS60 before 2.2.1.210, WN2000RPTv3 before 1.0.1.34, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.60, WNDR4300v2 before 1.0.0.58, and WNDR4500v3 before 1.0.0.58. plural NETGEAR The device contains an input verification vulnerability.Service operation interruption (DoS) It may be put into a state. NETGEAR D3600, etc. are all products of NETGEAR. NETGEAR D3600 is a wireless modem. NETGEAR R7500 is a wireless router. NETGEAR EX2700 is a wireless network signal extender
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202004-0779", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "d7800", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.1.44" }, { "model": "rbk20", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "2.3.0.28" }, { "model": "rbr20", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "2.3.0.28" }, { "model": "rbs20", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "2.3.0.28" }, { "model": "rbs40", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "2.3.0.28" }, { "model": "rbk50", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "2.3.0.32" }, { "model": "rbr50", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "2.3.0.32" }, { "model": "rbs50", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "2.3.0.32" }, { "model": "srr60", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "2.2.1.210" }, { "model": "srs60", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "2.2.1.210" }, { "model": "d3600", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.0.75" }, { "model": "d6000", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.0.75" }, { "model": "ex2700", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.1.52" }, { "model": "ex8000", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.1.180" }, { "model": "r7800", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.2.58" }, { "model": "srk60", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "2.2.1.210" }, { "model": "wn3100rp", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.60" }, { "model": "r7500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.38" }, { "model": "wndr4500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.58" }, { "model": "ex6200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.74" }, { "model": "wn3000rp", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.70" }, { "model": "wndr4300", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.58" }, { "model": "wn3000rp", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.68" }, { "model": "wn2000rpt", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.34" }, { "model": "d3600", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.0.75" }, { "model": "d6000", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.0.75" }, { "model": "d7800", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.1.44" }, { "model": "ex2700", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.1.52" }, { "model": "ex6200", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.1.74" }, { "model": "ex8000", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.1.80" }, { "model": "r7500", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.3.38" }, { "model": "r7800", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.2.58" }, { "model": "rbk20", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "2.3.0.28" }, { "model": "rbr20", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "2.3.0.28" }, { "model": "r7500v2", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.3.38" }, { "model": "wn3000rpv3", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.2.70" }, { "model": "ex6200v2", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.1.74" }, { "model": "wn2000rptv3", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.1.34" }, { "model": "wn3000rpv2", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.0.68" }, { "model": "wn3100rpv2", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.0.60" }, { "model": "wndr4300v2", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.0.58" }, { "model": "wndr4500v3", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.0.58" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-30688" }, { "db": "JVNDB", "id": "JVNDB-2019-015412" }, { "db": "NVD", "id": "CVE-2019-20717" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:netgear:d3600_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:d6000_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:d7800_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:ex2700_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:ex6200_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:ex8000_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:r7500_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:r7800_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk20_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr20_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-015412" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Wayne Low of Fortinets FortiGuard Labs", "sources": [ { "db": "CNNVD", "id": "CNNVD-202004-1301" } ], "trust": 0.6 }, "cve": "CVE-2019-20717", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 3.3, "confidentialityImpact": "NONE", "exploitabilityScore": 6.5, "id": "CVE-2019-20717", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "LOW", "trust": 1.0, "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 3.3, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2019-015412", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 3.3, "confidentialityImpact": "NONE", "exploitabilityScore": 6.5, "id": "CNVD-2020-30688", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "LOW", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "exploitabilityScore": 2.8, "id": "CVE-2019-20717", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 4.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "exploitabilityScore": 2.8, "id": "CVE-2019-20717", "impactScore": 1.4, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.5, "baseSeverity": "Medium", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2019-015412", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2019-20717", "trust": 1.0, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2019-20717", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "JVNDB-2019-015412", "trust": 0.8, "value": "Medium" }, { "author": "CNVD", "id": "CNVD-2020-30688", "trust": 0.6, "value": "LOW" }, { "author": "CNNVD", "id": "CNNVD-202004-1301", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-30688" }, { "db": "JVNDB", "id": "JVNDB-2019-015412" }, { "db": "CNNVD", "id": "CNNVD-202004-1301" }, { "db": "NVD", "id": "CVE-2019-20717" }, { "db": "NVD", "id": "CVE-2019-20717" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by denial of service. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D7800 before 1.0.1.44, EX2700 before 1.0.1.52, EX6200v2 before 1.0.1.74, EX8000 before 1.0.1.180, R7500v2 before 1.0.3.38, R7800 before 1.0.2.58, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, RBS40 before 2.3.0.28, SRK60 before 2.2.1.210, SRR60 before 2.2.1.210, SRS60 before 2.2.1.210, WN2000RPTv3 before 1.0.1.34, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.60, WNDR4300v2 before 1.0.0.58, and WNDR4500v3 before 1.0.0.58. plural NETGEAR The device contains an input verification vulnerability.Service operation interruption (DoS) It may be put into a state. NETGEAR D3600, etc. are all products of NETGEAR. NETGEAR D3600 is a wireless modem. NETGEAR R7500 is a wireless router. NETGEAR EX2700 is a wireless network signal extender", "sources": [ { "db": "NVD", "id": "CVE-2019-20717" }, { "db": "JVNDB", "id": "JVNDB-2019-015412" }, { "db": "CNVD", "id": "CNVD-2020-30688" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2019-20717", "trust": 3.0 }, { "db": "JVNDB", "id": "JVNDB-2019-015412", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2020-30688", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202004-1301", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-30688" }, { "db": "JVNDB", "id": "JVNDB-2019-015412" }, { "db": "CNNVD", "id": "CNNVD-202004-1301" }, { "db": "NVD", "id": "CVE-2019-20717" } ] }, "id": "VAR-202004-0779", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2020-30688" } ], "trust": 1.1408653544444443 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-30688" } ] }, "last_update_date": "2024-11-23T22:51:27.241000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Denial of Service on Some Routers, Extenders, and WiFi Systems, PSV-2018-0225", "trust": 0.8, "url": "https://kb.netgear.com/000061211/Security-Advisory-for-Denial-of-Service-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2018-0225" }, { "title": "Patch for Multiple NETGEAR product input verification error vulnerabilities (CNVD-2020-30688)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/219481" }, { "title": "Multiple NETGEAR Product input verification error vulnerability fixes", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=116882" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-30688" }, { "db": "JVNDB", "id": "JVNDB-2019-015412" }, { "db": "CNNVD", "id": "CNNVD-202004-1301" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "CWE-20", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-015412" }, { "db": "NVD", "id": "CVE-2019-20717" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-20717" }, { "trust": 1.6, "url": "https://kb.netgear.com/000061211/security-advisory-for-denial-of-service-on-some-routers-extenders-and-wifi-systems-psv-2018-0225" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-20717" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-30688" }, { "db": "JVNDB", "id": "JVNDB-2019-015412" }, { "db": "CNNVD", "id": "CNNVD-202004-1301" }, { "db": "NVD", "id": "CVE-2019-20717" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2020-30688" }, { "db": "JVNDB", "id": "JVNDB-2019-015412" }, { "db": "CNNVD", "id": "CNNVD-202004-1301" }, { "db": "NVD", "id": "CVE-2019-20717" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-05-29T00:00:00", "db": "CNVD", "id": "CNVD-2020-30688" }, { "date": "2020-05-19T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-015412" }, { "date": "2020-04-16T00:00:00", "db": "CNNVD", "id": "CNNVD-202004-1301" }, { "date": "2020-04-16T19:15:24.930000", "db": "NVD", "id": "CVE-2019-20717" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-05-29T00:00:00", "db": "CNVD", "id": "CNVD-2020-30688" }, { "date": "2020-05-19T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-015412" }, { "date": "2020-04-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202004-1301" }, { "date": "2024-11-21T04:39:10.313000", "db": "NVD", "id": "CVE-2019-20717" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202004-1301" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR Input verification vulnerabilities on devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-015412" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "input validation error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202004-1301" } ], "trust": 0.6 } }
var-202010-0579
Vulnerability from variot
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.63, R7800 before 1.0.2.60, R8900 before 1.0.4.26, R9000 before 1.0.4.26, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, RBK40 before 2.3.0.28, RBR40 before 2.3.0.28, RBS40 before 2.3.0.28, SRK60 before 2.2.2.20, SRR60 before 2.2.2.20, SRS60 before 2.2.2.20, WN3000RPv2 before 1.0.0.78, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.70, XR450 before 2.3.2.40, and XR500 before 2.3.2.40. plural NETGEAR The device contains an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202010-0579", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "r9000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.26" }, { "model": "rbr50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.32" }, { "model": "srs60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.2.2.20" }, { "model": "wndr4500v3", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.58" }, { "model": "wnr2000v5", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.70" }, { "model": "srk60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.2.2.20" }, { "model": "xr500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.2.40" }, { "model": "rbk40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.28" }, { "model": "rbr20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.28" }, { "model": "r7800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.60" }, { "model": "wn3000rpv2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.78" }, { "model": "rbk20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.28" }, { "model": "rbk50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.32" }, { "model": "rbs40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.28" }, { "model": "srr60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.2.2.20" }, { "model": "xr450", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.2.40" }, { "model": "d6100", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.63" }, { "model": "r8900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.26" }, { "model": "wndr4300v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.58" }, { "model": "rbs50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.32" }, { "model": "rbs20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.28" }, { "model": "d6100", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7800", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r8900", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r9000", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk20", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk50", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr20", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr50", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs20", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs50", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012214" }, { "db": "NVD", "id": "CVE-2020-26913" } ] }, "cve": "CVE-2020-26913", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "id": "CVE-2020-26913", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "id": "CVE-2020-26913", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-012214", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2020-26913", "trust": 1.0, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2020-26913", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "CVE-2020-26913", "trust": 0.8, "value": "Medium" }, { "author": "CNNVD", "id": "CNNVD-202010-344", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012214" }, { "db": "CNNVD", "id": "CNNVD-202010-344" }, { "db": "NVD", "id": "CVE-2020-26913" }, { "db": "NVD", "id": "CVE-2020-26913" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.63, R7800 before 1.0.2.60, R8900 before 1.0.4.26, R9000 before 1.0.4.26, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, RBK40 before 2.3.0.28, RBR40 before 2.3.0.28, RBS40 before 2.3.0.28, SRK60 before 2.2.2.20, SRR60 before 2.2.2.20, SRS60 before 2.2.2.20, WN3000RPv2 before 1.0.0.78, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.70, XR450 before 2.3.2.40, and XR500 before 2.3.2.40. plural NETGEAR The device contains an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state", "sources": [ { "db": "NVD", "id": "CVE-2020-26913" }, { "db": "JVNDB", "id": "JVNDB-2020-012214" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-26913", "trust": 2.4 }, { "db": "JVNDB", "id": "JVNDB-2020-012214", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202010-344", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012214" }, { "db": "CNNVD", "id": "CNNVD-202010-344" }, { "db": "NVD", "id": "CVE-2020-26913" } ] }, "id": "VAR-202010-0579", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.436391673 }, "last_update_date": "2024-11-23T22:58:08.273000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Stack\u00a0Overflow\u00a0on\u00a0Some\u00a0Routers\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2018-0140", "trust": 0.8, "url": "https://kb.netgear.com/000062340/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-WiFi-Systems-PSV-2018-0140" }, { "title": "Multiple NETGEAR Fix for device buffer error vulnerability", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=131131" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012214" }, { "db": "CNNVD", "id": "CNNVD-202010-344" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012214" }, { "db": "NVD", "id": "CVE-2020-26913" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://kb.netgear.com/000062340/security-advisory-for-post-authentication-stack-overflow-on-some-routers-and-wifi-systems-psv-2018-0140" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-26913" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012214" }, { "db": "CNNVD", "id": "CNNVD-202010-344" }, { "db": "NVD", "id": "CVE-2020-26913" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2020-012214" }, { "db": "CNNVD", "id": "CNNVD-202010-344" }, { "db": "NVD", "id": "CVE-2020-26913" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-27T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-012214" }, { "date": "2020-10-09T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-344" }, { "date": "2020-10-09T07:15:17.043000", "db": "NVD", "id": "CVE-2020-26913" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-27T05:42:00", "db": "JVNDB", "id": "JVNDB-2020-012214" }, { "date": "2020-10-21T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-344" }, { "date": "2024-11-21T05:20:28.870000", "db": "NVD", "id": "CVE-2020-26913" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-344" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Out-of-bounds write vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012214" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-344" } ], "trust": 0.6 } }
var-202012-1337
Vulnerability from variot
Certain NETGEAR devices are affected by stored XSS. This affects D6100 before 1.0.0.63, DM200 before 1.0.0.61, R7800 before 1.0.2.52, R8900 before 1.0.4.12, R9000 before 1.0.4.12, WN3000RPv2 before 1.0.0.68, and WNR2000v5 before 1.0.0.66. plural NETGEAR A cross-site scripting vulnerability exists in the device.Information may be obtained and information may be tampered with
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202012-1337", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "r9000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.12" }, { "model": "wn3000rpv2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.68" }, { "model": "wnr2000v5", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.66" }, { "model": "r7800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.52" }, { "model": "dm200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.61" }, { "model": "r8900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.12" }, { "model": "d6100", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.63" }, { "model": "wn3000rpv2", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "wnr2000v5", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "dm200", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r8900", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7800", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d6100", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r9000", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-014998" }, { "db": "NVD", "id": "CVE-2020-35808" } ] }, "cve": "CVE-2020-35808", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 3.5, "confidentialityImpact": "NONE", "exploitabilityScore": 6.8, "id": "CVE-2020-35808", "impactScore": 2.9, "integrityImpact": "PARTIAL", "severity": "LOW", "trust": 1.8, "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 1.7, "id": "CVE-2020-35808", "impactScore": 2.7, "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "cve@mitre.org", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 1.7, "id": "CVE-2020-35808", "impactScore": 2.7, "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 4.8, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "CVE-2020-35808", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "High", "scope": "Changed", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2020-35808", "trust": 1.0, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2020-35808", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "CVE-2020-35808", "trust": 0.8, "value": "Medium" }, { "author": "CNNVD", "id": "CNNVD-202012-1793", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-014998" }, { "db": "CNNVD", "id": "CNNVD-202012-1793" }, { "db": "NVD", "id": "CVE-2020-35808" }, { "db": "NVD", "id": "CVE-2020-35808" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by stored XSS. This affects D6100 before 1.0.0.63, DM200 before 1.0.0.61, R7800 before 1.0.2.52, R8900 before 1.0.4.12, R9000 before 1.0.4.12, WN3000RPv2 before 1.0.0.68, and WNR2000v5 before 1.0.0.66. plural NETGEAR A cross-site scripting vulnerability exists in the device.Information may be obtained and information may be tampered with", "sources": [ { "db": "NVD", "id": "CVE-2020-35808" }, { "db": "JVNDB", "id": "JVNDB-2020-014998" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-35808", "trust": 2.4 }, { "db": "JVNDB", "id": "JVNDB-2020-014998", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202012-1793", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-014998" }, { "db": "CNNVD", "id": "CNNVD-202012-1793" }, { "db": "NVD", "id": "CVE-2020-35808" } ] }, "id": "VAR-202012-1337", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.5452757871428571 }, "last_update_date": "2024-11-23T21:35:01.467000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Stored\u00a0Cross\u00a0Site\u00a0Scripting\u00a0on\u00a0Some\u00a0Routers\u00a0and\u00a0Range\u00a0Extenders,\u00a0PSV-2018-0158", "trust": 0.8, "url": "https://kb.netgear.com/000062708/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-and-Range-Extenders-PSV-2018-0158" }, { "title": "Certain NETGEAR devices Fixes for cross-site scripting vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=138162" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-014998" }, { "db": "CNNVD", "id": "CNNVD-202012-1793" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-79", "trust": 1.0 }, { "problemtype": "Cross-site scripting (CWE-79) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-014998" }, { "db": "NVD", "id": "CVE-2020-35808" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://kb.netgear.com/000062708/security-advisory-for-stored-cross-site-scripting-on-some-routers-and-range-extenders-psv-2018-0158" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-35808" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-014998" }, { "db": "CNNVD", "id": "CNNVD-202012-1793" }, { "db": "NVD", "id": "CVE-2020-35808" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2020-014998" }, { "db": "CNNVD", "id": "CNNVD-202012-1793" }, { "db": "NVD", "id": "CVE-2020-35808" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-09-07T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-014998" }, { "date": "2020-12-29T00:00:00", "db": "CNNVD", "id": "CNNVD-202012-1793" }, { "date": "2020-12-30T00:15:14.863000", "db": "NVD", "id": "CVE-2020-35808" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-09-07T08:54:00", "db": "JVNDB", "id": "JVNDB-2020-014998" }, { "date": "2021-01-12T00:00:00", "db": "CNNVD", "id": "CNNVD-202012-1793" }, { "date": "2024-11-21T05:28:10.323000", "db": "NVD", "id": "CVE-2020-35808" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202012-1793" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Cross-site scripting vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-014998" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "XSS", "sources": [ { "db": "CNNVD", "id": "CNNVD-202012-1793" } ], "trust": 0.6 } }
var-202012-1181
Vulnerability from variot
Certain NETGEAR devices are affected by stored XSS. This affects D7800 before 1.0.1.56, R7500v2 before 1.0.3.46, R7800 before 1.0.2.68, RAX120 before 1.0.0.78, RBK22 before 2.3.5.26, RBR20 before 2.3.5.26, RBS20 before 2.3.5.26, RBK40 before 2.3.5.30, RBR40 before 2.3.5.30, RBS40 before 2.3.5.30, RBK50 before 2.3.5.30, RBR50 before 2.3.5.30, RBS50 before 2.3.5.30, and WN3000RPv2 before 1.0.0.78. plural NETGEAR A cross-site scripting vulnerability exists in the device.Information may be obtained and information may be tampered with
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202012-1181", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "wn3000rpv2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.78" }, { "model": "rbk22", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.5.26" }, { "model": "rbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.5.30" }, { "model": "rbr20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.5.26" }, { "model": "rbs40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.5.30" }, { "model": "rbk40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.5.30" }, { "model": "rbk50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.5.30" }, { "model": "r7800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.68" }, { "model": "d7800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.56" }, { "model": "rax120", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.78" }, { "model": "rbs20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.5.26" }, { "model": "rbs50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.5.30" }, { "model": "rbr50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.5.30" }, { "model": "r7500v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.46" }, { "model": "rax120", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr20", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk22", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs20", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7500v2", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d7800", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7800", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-014996" }, { "db": "NVD", "id": "CVE-2020-35806" } ] }, "cve": "CVE-2020-35806", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 3.5, "confidentialityImpact": "NONE", "exploitabilityScore": 6.8, "id": "CVE-2020-35806", "impactScore": 2.9, "integrityImpact": "PARTIAL", "severity": "LOW", "trust": 1.8, "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 1.7, "id": "CVE-2020-35806", "impactScore": 2.7, "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "cve@mitre.org", "availabilityImpact": "NONE", "baseScore": 6.0, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.8, "id": "CVE-2020-35806", "impactScore": 5.2, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 4.8, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "CVE-2020-35806", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "High", "scope": "Changed", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2020-35806", "trust": 1.0, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2020-35806", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "CVE-2020-35806", "trust": 0.8, "value": "Medium" }, { "author": "CNNVD", "id": "CNNVD-202012-1794", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-014996" }, { "db": "CNNVD", "id": "CNNVD-202012-1794" }, { "db": "NVD", "id": "CVE-2020-35806" }, { "db": "NVD", "id": "CVE-2020-35806" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by stored XSS. This affects D7800 before 1.0.1.56, R7500v2 before 1.0.3.46, R7800 before 1.0.2.68, RAX120 before 1.0.0.78, RBK22 before 2.3.5.26, RBR20 before 2.3.5.26, RBS20 before 2.3.5.26, RBK40 before 2.3.5.30, RBR40 before 2.3.5.30, RBS40 before 2.3.5.30, RBK50 before 2.3.5.30, RBR50 before 2.3.5.30, RBS50 before 2.3.5.30, and WN3000RPv2 before 1.0.0.78. plural NETGEAR A cross-site scripting vulnerability exists in the device.Information may be obtained and information may be tampered with", "sources": [ { "db": "NVD", "id": "CVE-2020-35806" }, { "db": "JVNDB", "id": "JVNDB-2020-014996" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-35806", "trust": 2.4 }, { "db": "JVNDB", "id": "JVNDB-2020-014996", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202012-1794", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-014996" }, { "db": "CNNVD", "id": "CNNVD-202012-1794" }, { "db": "NVD", "id": "CVE-2020-35806" } ] }, "id": "VAR-202012-1181", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.36092577615384613 }, "last_update_date": "2024-11-23T21:58:51.562000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Stored\u00a0Cross\u00a0Site\u00a0Scripting\u00a0on\u00a0Some\u00a0Routers\u00a0and\u00a0Orbi\u00a0WiFi\u00a0Systems,\u00a0PSV-2018-0539", "trust": 0.8, "url": "https://kb.netgear.com/000062729/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-and-Orbi-WiFi-Systems-PSV-2018-0539" }, { "title": "Certain NETGEAR devices Fixes for cross-site scripting vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=138163" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-014996" }, { "db": "CNNVD", "id": "CNNVD-202012-1794" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-79", "trust": 1.0 }, { "problemtype": "Cross-site scripting (CWE-79) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-014996" }, { "db": "NVD", "id": "CVE-2020-35806" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://kb.netgear.com/000062729/security-advisory-for-stored-cross-site-scripting-on-some-routers-and-orbi-wifi-systems-psv-2018-0539" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-35806" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-014996" }, { "db": "CNNVD", "id": "CNNVD-202012-1794" }, { "db": "NVD", "id": "CVE-2020-35806" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2020-014996" }, { "db": "CNNVD", "id": "CNNVD-202012-1794" }, { "db": "NVD", "id": "CVE-2020-35806" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-09-07T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-014996" }, { "date": "2020-12-29T00:00:00", "db": "CNNVD", "id": "CNNVD-202012-1794" }, { "date": "2020-12-30T00:15:14.737000", "db": "NVD", "id": "CVE-2020-35806" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-09-07T08:54:00", "db": "JVNDB", "id": "JVNDB-2020-014996" }, { "date": "2021-01-12T00:00:00", "db": "CNNVD", "id": "CNNVD-202012-1794" }, { "date": "2024-11-21T05:28:09.920000", "db": "NVD", "id": "CVE-2020-35806" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202012-1794" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Cross-site scripting vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-014996" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "XSS", "sources": [ { "db": "CNNVD", "id": "CNNVD-202012-1794" } ], "trust": 0.6 } }
var-202112-2346
Vulnerability from variot
Certain NETGEAR devices are affected by disclosure of sensitive information. A UPnP request reveals a device's serial number, which can be used for a password reset. This affects D7800 before 1.0.1.66, EX2700 before 1.0.1.68, WN3000RPv2 before 1.0.0.90, WN3000RPv3 before 1.0.2.100, LBR1020 before 2.6.5.20, LBR20 before 2.6.5.32, R6700AX before 1.0.10.110, R7800 before 1.0.2.86, R8900 before 1.0.5.38, R9000 before 1.0.5.38, RAX10 before 1.0.10.110, RAX120v1 before 1.2.3.28, RAX120v2 before 1.2.3.28, RAX70 before 1.0.10.110, RAX78 before 1.0.10.110, XR450 before 2.3.2.130, XR500 before 2.3.2.130, and XR700 before 1.0.1.46. This affects D7800 prior to 1.0.1.66, EX2700 prior to 1.0.1.68, WN3000RPv2 prior to 1.0.0.90, WN3000RPv3 prior to 1.0.2.100, LBR1020 prior to 2.6.5.20, LBR20 prior to 2.6.5.32, R6700AX prior to 1.0.10.110, R7800 prior to 1.0.2.86, R8900 prior to 1.0.5.38, R9000 prior to 1.0.5.38, RAX10 prior to 1.0.10.110, RAX120v1 prior to 1.2.3.28, RAX120v2 prior to 1.2.3.28, RAX70 prior to 1.0.10.110, RAX78 prior to 1.0.10.110, XR450 prior to 2.3.2.130, XR500 prior to 2.3.2.130, and XR700 prior to 1.0.1.46
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2346", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "xr500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.2.130" }, { "model": "lbr20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.5.32" }, { "model": "rax120v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.3.28" }, { "model": "rax10", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.10.110" }, { "model": "ex2700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.68" }, { "model": "r6700ax", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.10.110" }, { "model": "rax78", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.10.110" }, { "model": "lbr1020", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.5.20" }, { "model": "r7800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.86" }, { "model": "r9000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.38" }, { "model": "xr700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.46" }, { "model": "wn3000rpv3", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.100" }, { "model": "rax120v1", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.3.28" }, { "model": "wn3000rpv2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.90" }, { "model": "rax70", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.10.110" }, { "model": "r8900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.38" }, { "model": "xr450", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.2.130" }, { "model": "d7800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.66" }, { "model": "lbr1020", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d7800", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "lbr20", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "wn3000rpv2", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex2700", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r9000", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r6700ax", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7800", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r8900", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "wn3000rpv3", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017180" }, { "db": "NVD", "id": "CVE-2021-45603" } ] }, "cve": "CVE-2021-45603", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 2.1, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 3.9, "id": "CVE-2021-45603", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "LOW", "trust": 1.9, "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "id": "CVE-2021-45603", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "id": "CVE-2021-45603", "impactScore": 4.2, "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:L", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "NVD", "availabilityImpact": "None", "baseScore": 5.5, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45603", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-45603", "trust": 1.0, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45603", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "CVE-2021-45603", "trust": 0.8, "value": "Medium" }, { "author": "CNNVD", "id": "CNNVD-202112-2399", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45603", "trust": 0.1, "value": "LOW" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45603" }, { "db": "JVNDB", "id": "JVNDB-2021-017180" }, { "db": "CNNVD", "id": "CNNVD-202112-2399" }, { "db": "NVD", "id": "CVE-2021-45603" }, { "db": "NVD", "id": "CVE-2021-45603" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by disclosure of sensitive information. A UPnP request reveals a device\u0027s serial number, which can be used for a password reset. This affects D7800 before 1.0.1.66, EX2700 before 1.0.1.68, WN3000RPv2 before 1.0.0.90, WN3000RPv3 before 1.0.2.100, LBR1020 before 2.6.5.20, LBR20 before 2.6.5.32, R6700AX before 1.0.10.110, R7800 before 1.0.2.86, R8900 before 1.0.5.38, R9000 before 1.0.5.38, RAX10 before 1.0.10.110, RAX120v1 before 1.2.3.28, RAX120v2 before 1.2.3.28, RAX70 before 1.0.10.110, RAX78 before 1.0.10.110, XR450 before 2.3.2.130, XR500 before 2.3.2.130, and XR700 before 1.0.1.46. This affects D7800 prior to 1.0.1.66, EX2700 prior to 1.0.1.68, WN3000RPv2 prior to 1.0.0.90, WN3000RPv3 prior to 1.0.2.100, LBR1020 prior to 2.6.5.20, LBR20 prior to 2.6.5.32, R6700AX prior to 1.0.10.110, R7800 prior to 1.0.2.86, R8900 prior to 1.0.5.38, R9000 prior to 1.0.5.38, RAX10 prior to 1.0.10.110, RAX120v1 prior to 1.2.3.28, RAX120v2 prior to 1.2.3.28, RAX70 prior to 1.0.10.110, RAX78 prior to 1.0.10.110, XR450 prior to 2.3.2.130, XR500 prior to 2.3.2.130, and XR700 prior to 1.0.1.46", "sources": [ { "db": "NVD", "id": "CVE-2021-45603" }, { "db": "JVNDB", "id": "JVNDB-2021-017180" }, { "db": "VULMON", "id": "CVE-2021-45603" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45603", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017180", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2399", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45603", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45603" }, { "db": "JVNDB", "id": "JVNDB-2021-017180" }, { "db": "CNNVD", "id": "CNNVD-202112-2399" }, { "db": "NVD", "id": "CVE-2021-45603" } ] }, "id": "VAR-202112-2346", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.47084348 }, "last_update_date": "2024-11-23T22:47:32.677000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0\u0026\u00a0Sensitive\u00a0Information\u00a0Disclosure\u00a0on\u00a0Multiple\u00a0Products,\u00a0PSV-2021-0169\u00a0\u0026\u00a0PSV-2021-0171", "trust": 0.8, "url": "https://kb.netgear.com/000064407/Security-Advisory-for-Post-Authentication-Command-Injection-Sensitive-Information-Disclosure-on-Multiple-Products-PSV-2021-0169-PSV-2021-0171" }, { "title": "Netgear NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=177120" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017180" }, { "db": "CNNVD", "id": "CNNVD-202112-2399" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-200", "trust": 1.0 }, { "problemtype": "information leak (CWE-200) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017180" }, { "db": "NVD", "id": "CVE-2021-45603" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://immersivelabs.com/resources/blog/netgear-vulnerabilities-could-put-small-business-routers-at-risk/" }, { "trust": 1.7, "url": "https://kb.netgear.com/000064407/security-advisory-for-post-authentication-command-injection-sensitive-information-disclosure-on-multiple-products-psv-2021-0169-psv-2021-0171" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45603" }, { "trust": 0.8, "url": "https://www.immersivelabs.com/press/netgear-vulnerabilities-could-put-small-business-routers-at-risk/" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/200.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45603" }, { "db": "JVNDB", "id": "JVNDB-2021-017180" }, { "db": "CNNVD", "id": "CNNVD-202112-2399" }, { "db": "NVD", "id": "CVE-2021-45603" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45603" }, { "db": "JVNDB", "id": "JVNDB-2021-017180" }, { "db": "CNNVD", "id": "CNNVD-202112-2399" }, { "db": "NVD", "id": "CVE-2021-45603" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45603" }, { "date": "2023-01-06T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017180" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2399" }, { "date": "2021-12-26T01:15:17.853000", "db": "NVD", "id": "CVE-2021-45603" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-06T00:00:00", "db": "VULMON", "id": "CVE-2021-45603" }, { "date": "2023-01-06T06:22:00", "db": "JVNDB", "id": "JVNDB-2021-017180" }, { "date": "2022-01-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2399" }, { "date": "2024-11-21T06:32:38.527000", "db": "NVD", "id": "CVE-2021-45603" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2399" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Device information disclosure vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017180" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "information disclosure", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2399" } ], "trust": 0.6 } }
var-202004-0785
Vulnerability from variot
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D6100 before 1.0.0.63, DM200 before 1.0.0.58, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7300 before 1.0.2.136, EX8000 before 1.0.1.180, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.60, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32. plural NETGEAR The device is vulnerable to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR R8900, etc. are all wireless routers from NETGEAR. The vulnerability stems from the fact that when the network system or product performs operations on the memory, the data boundary is not correctly verified, resulting in incorrect read and write operations to other associated memory locations. Attackers can use this vulnerability to cause buffer overflow or heap overflow
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202004-0785", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "r7800", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.2.52" }, { "model": "xr500", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "2.3.2.32" }, { "model": "r8900", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.4.2" }, { "model": "d3600", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.0.75" }, { "model": "d6000", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.0.75" }, { "model": "ex8000", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.1.180" }, { "model": "d6100", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.0.63" }, { "model": "dm200", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.0.58" }, { "model": "r9000", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.4.2" }, { "model": "ex7300", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.2.136" }, { "model": "ex6400", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.2.136" }, { "model": "ex2700", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.1.48" }, { "model": "wn3100rp", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.60" }, { "model": "ex6150", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.76" }, { "model": "ex6200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.72" }, { "model": "wndr4500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.58" }, { "model": "wn2000rpt", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.32" }, { "model": "wnr2000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.68" }, { "model": "wn3000rp", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.70" }, { "model": "ex6100", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.76" }, { "model": "wn3000rp", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.68" }, { "model": "wndr4300", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.58" }, { "model": "d3600", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.0.75" }, { "model": "d6000", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.0.75" }, { "model": "d6100", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.0.63" }, { "model": "dm200", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.0.58" }, { "model": "ex2700", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.1.48" }, { "model": "ex6100", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.1.76" }, { "model": "ex6150", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.1.76" }, { "model": "ex6200", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.1.72" }, { "model": "ex6400", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.2.136" }, { "model": "ex7300", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.2.136" }, { "model": "ex6100v2", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.1.76" }, { "model": "ex6150v2", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.1.76" }, { "model": "wn2000rptv3", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.1.32" }, { "model": "wn3000rpv3", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.2.70" }, { "model": "wn3000rpv2", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.0.68" }, { "model": "wn3100rpv2", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.0.60" }, { "model": "wndr4300v2", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.0.58" }, { "model": "wndr4500v3", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.0.58" }, { "model": "wnr2000v5", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.0.68" }, { "model": "ex6200v2", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.0.1.72" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-61056" }, { "db": "JVNDB", "id": "JVNDB-2019-015409" }, { "db": "NVD", "id": "CVE-2019-20723" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:netgear:d3600_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:d6000_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:d6100_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:dm200_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:ex2700_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:ex6100_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:ex6150_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:ex6200_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:ex6400_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:ex7300_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-015409" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "aircut", "sources": [ { "db": "CNNVD", "id": "CNNVD-202004-1307" } ], "trust": 0.6 }, "cve": "CVE-2019-20723", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "id": "CVE-2019-20723", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.0, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2019-015409", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "id": "CNVD-2021-61056", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "id": "CVE-2019-20723", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "id": "CVE-2019-20723", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2019-015409", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2019-20723", "trust": 1.0, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2019-20723", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "JVNDB-2019-015409", "trust": 0.8, "value": "Medium" }, { "author": "CNVD", "id": "CNVD-2021-61056", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202004-1307", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-61056" }, { "db": "JVNDB", "id": "JVNDB-2019-015409" }, { "db": "CNNVD", "id": "CNNVD-202004-1307" }, { "db": "NVD", "id": "CVE-2019-20723" }, { "db": "NVD", "id": "CVE-2019-20723" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D6100 before 1.0.0.63, DM200 before 1.0.0.58, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7300 before 1.0.2.136, EX8000 before 1.0.1.180, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.60, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32. plural NETGEAR The device is vulnerable to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR R8900, etc. are all wireless routers from NETGEAR. The vulnerability stems from the fact that when the network system or product performs operations on the memory, the data boundary is not correctly verified, resulting in incorrect read and write operations to other associated memory locations. Attackers can use this vulnerability to cause buffer overflow or heap overflow", "sources": [ { "db": "NVD", "id": "CVE-2019-20723" }, { "db": "JVNDB", "id": "JVNDB-2019-015409" }, { "db": "CNVD", "id": "CNVD-2021-61056" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2019-20723", "trust": 3.0 }, { "db": "JVNDB", "id": "JVNDB-2019-015409", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-61056", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202004-1307", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-61056" }, { "db": "JVNDB", "id": "JVNDB-2019-015409" }, { "db": "CNNVD", "id": "CNNVD-202004-1307" }, { "db": "NVD", "id": "CVE-2019-20723" } ] }, "id": "VAR-202004-0785", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-61056" } ], "trust": 1.1791139654166667 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-61056" } ] }, "last_update_date": "2024-11-23T21:59:21.256000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Post-Authentication Stack Overflow on Some Routers, Gateways, and Extenders, PSV-2018-0146", "trust": 0.8, "url": "https://kb.netgear.com/000061205/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2018-0146" }, { "title": "Patch for Buffer overflow vulnerabilities in multiple NETGEAR products (CNVD-2021-61056)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/285371" }, { "title": "Multiple NETGEAR Product Buffer Error Vulnerability Fix", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=114817" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-61056" }, { "db": "JVNDB", "id": "JVNDB-2019-015409" }, { "db": "CNNVD", "id": "CNNVD-202004-1307" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-015409" }, { "db": "NVD", "id": "CVE-2019-20723" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-20723" }, { "trust": 1.6, "url": "https://kb.netgear.com/000061205/security-advisory-for-post-authentication-stack-overflow-on-some-routers-gateways-and-extenders-psv-2018-0146" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-20723" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-61056" }, { "db": "JVNDB", "id": "JVNDB-2019-015409" }, { "db": "CNNVD", "id": "CNNVD-202004-1307" }, { "db": "NVD", "id": "CVE-2019-20723" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-61056" }, { "db": "JVNDB", "id": "JVNDB-2019-015409" }, { "db": "CNNVD", "id": "CNNVD-202004-1307" }, { "db": "NVD", "id": "CVE-2019-20723" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-08-11T00:00:00", "db": "CNVD", "id": "CNVD-2021-61056" }, { "date": "2020-05-19T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-015409" }, { "date": "2020-04-16T00:00:00", "db": "CNNVD", "id": "CNNVD-202004-1307" }, { "date": "2020-04-16T19:15:25.337000", "db": "NVD", "id": "CVE-2019-20723" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-08-11T00:00:00", "db": "CNVD", "id": "CNVD-2021-61056" }, { "date": "2020-05-19T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-015409" }, { "date": "2020-04-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202004-1307" }, { "date": "2024-11-21T04:39:11.273000", "db": "NVD", "id": "CVE-2019-20723" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202004-1307" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR Out-of-bounds write vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-015409" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202004-1307" } ], "trust": 0.6 } }
var-202112-2291
Vulnerability from variot
Certain NETGEAR devices are affected by server-side injection. This affects D7800 before 1.0.1.58, DM200 before 1.0.0.66, EX2700 before 1.0.1.56, EX6150v2 before 1.0.1.86, EX6100v2 before 1.0.1.86, EX6200v2 before 1.0.1.78, EX6250 before 1.0.0.110, EX6410 before 1.0.0.110, EX6420 before 1.0.0.110, EX6400v2 before 1.0.0.110, EX7300 before 1.0.2.144, EX6400 before 1.0.2.144, EX7320 before 1.0.0.110, EX7300v2 before 1.0.0.110, R7500v2 before 1.0.3.48, R7800 before 1.0.2.68, R8900 before 1.0.5.2, R9000 before 1.0.5.2, RAX120 before 1.0.1.90, RBK40 before 2.5.1.16, RBK20 before 2.5.1.16, RBR20 before 2.5.1.16, RBS20 before 2.5.1.16, RBK50 before 2.5.1.16, RBR50 before 2.5.1.16, RBS50 before 2.5.1.16, RBS50Y before 2.6.1.40, WN3000RPv2 before 1.0.0.78, WN3000RPv3 before 1.0.2.80, WNR2000v5 before 1.0.0.72, XR500 before 2.3.2.56, and XR700 before 1.0.1.20. plural NETGEAR The device has an injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects D7800 prior to 1.0.1.58, DM200 prior to 1.0.0.66, EX2700 prior to 1.0.1.56, EX6150v2 prior to 1.0.1.86, EX6100v2 prior to 1.0.1.86, EX6200v2 prior to 1.0.1.78, EX6250 prior to 1.0.0.110, EX6410 prior to 1.0.0.110, EX6420 prior to 1.0.0.110, EX6400v2 prior to 1.0.0.110, EX7300 prior to 1.0.2.144, EX6400 prior to 1.0.2.144, EX7320 prior to 1.0.0.110, EX7300v2 prior to 1.0.0.110, R7500v2 prior to 1.0.3.48, R7800 prior to 1.0.2.68, R8900 prior to 1.0.5.2, R9000 prior to 1.0.5.2, RAX120 prior to 1.0.1.90, RBK40 prior to 2.5.1.16, RBK20 prior to 2.5.1.16, RBR20 prior to 2.5.1.16, RBS20 prior to 2.5.1.16, RBK50 prior to 2.5.1.16, RBR50 prior to 2.5.1.16, RBS50 prior to 2.5.1.16, RBS50Y prior to 2.6.1.40, WN3000RPv2 prior to 1.0.0.78, WN3000RPv3 prior to 1.0.2.80, WNR2000v5 prior to 1.0.0.72, XR500 prior to 2.3.2.56, and XR700 prior to 1.0.1.20
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2291", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.1.16" }, { "model": "ex2700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.56" }, { "model": "r7500v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.48" }, { "model": "rbk40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.1.16" }, { "model": "ex6400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.144" }, { "model": "ex6400v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.110" }, { "model": "ex6250", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.110" }, { "model": "rbk20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.1.16" }, { "model": "rbk50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.1.16" }, { "model": "rbs20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.1.16" }, { "model": "rbs50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.1.16" }, { "model": "ex6100v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.86" }, { "model": "wnr2000v5", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.72" }, { "model": "ex6200v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.78" }, { "model": "d7800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.58" }, { "model": "wn3000rpv2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.78" }, { "model": "ex6150v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.86" }, { "model": "ex6420", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.110" }, { "model": "ex7320", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.110" }, { "model": "rbs50y", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.40" }, { "model": "wn3000rpv3", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.80" }, { "model": "r8900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.2" }, { "model": "ex7300", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.144" }, { "model": "r7800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.68" }, { "model": "dm200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.66" }, { "model": "r9000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.2" }, { "model": "rax120", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.90" }, { "model": "xr500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.2.56" }, { "model": "rbr20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.1.16" }, { "model": "xr700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.20" }, { "model": "ex6410", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.110" }, { "model": "ex7300v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.110" }, { "model": "d7800", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex2700", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex6150v2", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex6100v2", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex6200v2", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex6400v2", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "dm200", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex6250", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex6420", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex6410", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017535" }, { "db": "NVD", "id": "CVE-2021-45658" } ] }, "cve": "CVE-2021-45658", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2021-45658", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2021-45658", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "cve@mitre.org", "availabilityImpact": "NONE", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "id": "CVE-2021-45658", "impactScore": 5.2, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45658", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-45658", "trust": 1.0, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2021-45658", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2021-45658", "trust": 0.8, "value": "Critical" }, { "author": "CNNVD", "id": "CNNVD-202112-2454", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017535" }, { "db": "CNNVD", "id": "CNNVD-202112-2454" }, { "db": "NVD", "id": "CVE-2021-45658" }, { "db": "NVD", "id": "CVE-2021-45658" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by server-side injection. This affects D7800 before 1.0.1.58, DM200 before 1.0.0.66, EX2700 before 1.0.1.56, EX6150v2 before 1.0.1.86, EX6100v2 before 1.0.1.86, EX6200v2 before 1.0.1.78, EX6250 before 1.0.0.110, EX6410 before 1.0.0.110, EX6420 before 1.0.0.110, EX6400v2 before 1.0.0.110, EX7300 before 1.0.2.144, EX6400 before 1.0.2.144, EX7320 before 1.0.0.110, EX7300v2 before 1.0.0.110, R7500v2 before 1.0.3.48, R7800 before 1.0.2.68, R8900 before 1.0.5.2, R9000 before 1.0.5.2, RAX120 before 1.0.1.90, RBK40 before 2.5.1.16, RBK20 before 2.5.1.16, RBR20 before 2.5.1.16, RBS20 before 2.5.1.16, RBK50 before 2.5.1.16, RBR50 before 2.5.1.16, RBS50 before 2.5.1.16, RBS50Y before 2.6.1.40, WN3000RPv2 before 1.0.0.78, WN3000RPv3 before 1.0.2.80, WNR2000v5 before 1.0.0.72, XR500 before 2.3.2.56, and XR700 before 1.0.1.20. plural NETGEAR The device has an injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects D7800 prior to 1.0.1.58, DM200 prior to 1.0.0.66, EX2700 prior to 1.0.1.56, EX6150v2 prior to 1.0.1.86, EX6100v2 prior to 1.0.1.86, EX6200v2 prior to 1.0.1.78, EX6250 prior to 1.0.0.110, EX6410 prior to 1.0.0.110, EX6420 prior to 1.0.0.110, EX6400v2 prior to 1.0.0.110, EX7300 prior to 1.0.2.144, EX6400 prior to 1.0.2.144, EX7320 prior to 1.0.0.110, EX7300v2 prior to 1.0.0.110, R7500v2 prior to 1.0.3.48, R7800 prior to 1.0.2.68, R8900 prior to 1.0.5.2, R9000 prior to 1.0.5.2, RAX120 prior to 1.0.1.90, RBK40 prior to 2.5.1.16, RBK20 prior to 2.5.1.16, RBR20 prior to 2.5.1.16, RBS20 prior to 2.5.1.16, RBK50 prior to 2.5.1.16, RBR50 prior to 2.5.1.16, RBS50 prior to 2.5.1.16, RBS50Y prior to 2.6.1.40, WN3000RPv2 prior to 1.0.0.78, WN3000RPv3 prior to 1.0.2.80, WNR2000v5 prior to 1.0.0.72, XR500 prior to 2.3.2.56, and XR700 prior to 1.0.1.20", "sources": [ { "db": "NVD", "id": "CVE-2021-45658" }, { "db": "JVNDB", "id": "JVNDB-2021-017535" }, { "db": "VULMON", "id": "CVE-2021-45658" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45658", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017535", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2454", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45658", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45658" }, { "db": "JVNDB", "id": "JVNDB-2021-017535" }, { "db": "CNNVD", "id": "CNNVD-202112-2454" }, { "db": "NVD", "id": "CVE-2021-45658" } ] }, "id": "VAR-202112-2291", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.4233103683333333 }, "last_update_date": "2024-11-23T22:10:56.853000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Server\u00a0Side\u00a0Injection\u00a0on\u00a0Some\u00a0Routers,\u00a0Extenders,\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2019-0125", "trust": 0.8, "url": "https://kb.netgear.com/000064062/Security-Advisory-for-Server-Side-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2019-0125" }, { "title": "Netgear NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=176216" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017535" }, { "db": "CNNVD", "id": "CNNVD-202112-2454" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-74", "trust": 1.0 }, { "problemtype": "injection (CWE-74) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017535" }, { "db": "NVD", "id": "CVE-2021-45658" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064062/security-advisory-for-server-side-injection-on-some-routers-extenders-and-wifi-systems-psv-2019-0125" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45658" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45658" }, { "db": "JVNDB", "id": "JVNDB-2021-017535" }, { "db": "CNNVD", "id": "CNNVD-202112-2454" }, { "db": "NVD", "id": "CVE-2021-45658" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45658" }, { "db": "JVNDB", "id": "JVNDB-2021-017535" }, { "db": "CNNVD", "id": "CNNVD-202112-2454" }, { "db": "NVD", "id": "CVE-2021-45658" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45658" }, { "date": "2023-01-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017535" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2454" }, { "date": "2021-12-26T01:15:20.467000", "db": "NVD", "id": "CVE-2021-45658" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-27T00:00:00", "db": "VULMON", "id": "CVE-2021-45658" }, { "date": "2023-01-25T01:41:00", "db": "JVNDB", "id": "JVNDB-2021-017535" }, { "date": "2022-01-11T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2454" }, { "date": "2024-11-21T06:32:48.427000", "db": "NVD", "id": "CVE-2021-45658" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2454" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Device Injection Vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017535" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2454" } ], "trust": 0.6 } }
var-202112-2347
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.66, EX2700 before 1.0.1.68, WN3000RPv2 before 1.0.0.90, WN3000RPv3 before 1.0.2.100, LBR1020 before 2.6.5.20, LBR20 before 2.6.5.32, R6700AX before 1.0.10.110, R7800 before 1.0.2.86, R8900 before 1.0.5.38, R9000 before 1.0.5.38, RAX10 before 1.0.10.110, RAX120v1 before 1.2.3.28, RAX120v2 before 1.2.3.28, RAX70 before 1.0.10.110, RAX78 before 1.0.10.110, XR450 before 2.3.2.130, XR500 before 2.3.2.130, and XR700 before 1.0.1.46. plural NETGEAR On the device OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects D7800 prior to 1.0.1.66, EX2700 prior to 1.0.1.68, WN3000RPv2 prior to 1.0.0.90, WN3000RPv3 prior to 1.0.2.100, LBR1020 prior to 2.6.5.20, LBR20 prior to 2.6.5.32, R6700AX prior to 1.0.10.110, R7800 prior to 1.0.2.86, R8900 prior to 1.0.5.38, R9000 prior to 1.0.5.38, RAX10 prior to 1.0.10.110, RAX120v1 prior to 1.2.3.28, RAX120v2 prior to 1.2.3.28, RAX70 prior to 1.0.10.110, RAX78 prior to 1.0.10.110, XR450 prior to 2.3.2.130, XR500 prior to 2.3.2.130, and XR700 prior to 1.0.1.46
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2347", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "xr500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.2.130" }, { "model": "lbr20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.5.32" }, { "model": "rax120v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.3.28" }, { "model": "rax10", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.10.110" }, { "model": "ex2700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.68" }, { "model": "r6700ax", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.10.110" }, { "model": "rax78", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.10.110" }, { "model": "lbr1020", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.5.20" }, { "model": "r7800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.86" }, { "model": "r9000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.38" }, { "model": "xr700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.46" }, { "model": "wn3000rpv3", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.100" }, { "model": "rax120v1", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.3.28" }, { "model": "wn3000rpv2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.90" }, { "model": "rax70", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.10.110" }, { "model": "r8900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.38" }, { "model": "xr450", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.2.130" }, { "model": "d7800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.66" }, { "model": "lbr1020", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d7800", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "lbr20", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "wn3000rpv2", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex2700", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r9000", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r6700ax", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7800", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r8900", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "wn3000rpv3", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017181" }, { "db": "NVD", "id": "CVE-2021-45602" } ] }, "cve": "CVE-2021-45602", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 4.6, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 3.9, "id": "CVE-2021-45602", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.9, "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "id": "CVE-2021-45602", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "id": "CVE-2021-45602", "impactScore": 4.2, "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:L", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45602", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-45602", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-45602", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "CVE-2021-45602", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-202112-2398", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-45602", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45602" }, { "db": "JVNDB", "id": "JVNDB-2021-017181" }, { "db": "CNNVD", "id": "CNNVD-202112-2398" }, { "db": "NVD", "id": "CVE-2021-45602" }, { "db": "NVD", "id": "CVE-2021-45602" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.66, EX2700 before 1.0.1.68, WN3000RPv2 before 1.0.0.90, WN3000RPv3 before 1.0.2.100, LBR1020 before 2.6.5.20, LBR20 before 2.6.5.32, R6700AX before 1.0.10.110, R7800 before 1.0.2.86, R8900 before 1.0.5.38, R9000 before 1.0.5.38, RAX10 before 1.0.10.110, RAX120v1 before 1.2.3.28, RAX120v2 before 1.2.3.28, RAX70 before 1.0.10.110, RAX78 before 1.0.10.110, XR450 before 2.3.2.130, XR500 before 2.3.2.130, and XR700 before 1.0.1.46. plural NETGEAR On the device OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects D7800 prior to 1.0.1.66, EX2700 prior to 1.0.1.68, WN3000RPv2 prior to 1.0.0.90, WN3000RPv3 prior to 1.0.2.100, LBR1020 prior to 2.6.5.20, LBR20 prior to 2.6.5.32, R6700AX prior to 1.0.10.110, R7800 prior to 1.0.2.86, R8900 prior to 1.0.5.38, R9000 prior to 1.0.5.38, RAX10 prior to 1.0.10.110, RAX120v1 prior to 1.2.3.28, RAX120v2 prior to 1.2.3.28, RAX70 prior to 1.0.10.110, RAX78 prior to 1.0.10.110, XR450 prior to 2.3.2.130, XR500 prior to 2.3.2.130, and XR700 prior to 1.0.1.46", "sources": [ { "db": "NVD", "id": "CVE-2021-45602" }, { "db": "JVNDB", "id": "JVNDB-2021-017181" }, { "db": "VULMON", "id": "CVE-2021-45602" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45602", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017181", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2398", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45602", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45602" }, { "db": "JVNDB", "id": "JVNDB-2021-017181" }, { "db": "CNNVD", "id": "CNNVD-202112-2398" }, { "db": "NVD", "id": "CVE-2021-45602" } ] }, "id": "VAR-202112-2347", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.47084348 }, "last_update_date": "2024-11-23T22:50:58.411000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0\u0026\u00a0Sensitive\u00a0Information\u00a0Disclosure\u00a0on\u00a0Multiple\u00a0Products,\u00a0PSV-2021-0169\u00a0\u0026\u00a0PSV-2021-0171", "trust": 0.8, "url": "https://kb.netgear.com/000064407/Security-Advisory-for-Post-Authentication-Command-Injection-Sensitive-Information-Disclosure-on-Multiple-Products-PSV-2021-0169-PSV-2021-0171" }, { "title": "Netgear NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=177119" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017181" }, { "db": "CNNVD", "id": "CNNVD-202112-2398" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-78", "trust": 1.0 }, { "problemtype": "OS Command injection (CWE-78) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017181" }, { "db": "NVD", "id": "CVE-2021-45602" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://immersivelabs.com/resources/blog/netgear-vulnerabilities-could-put-small-business-routers-at-risk/" }, { "trust": 1.7, "url": "https://kb.netgear.com/000064407/security-advisory-for-post-authentication-command-injection-sensitive-information-disclosure-on-multiple-products-psv-2021-0169-psv-2021-0171" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45602" }, { "trust": 0.8, "url": "https://www.immersivelabs.com/press/netgear-vulnerabilities-could-put-small-business-routers-at-risk/" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45602" }, { "db": "JVNDB", "id": "JVNDB-2021-017181" }, { "db": "CNNVD", "id": "CNNVD-202112-2398" }, { "db": "NVD", "id": "CVE-2021-45602" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45602" }, { "db": "JVNDB", "id": "JVNDB-2021-017181" }, { "db": "CNNVD", "id": "CNNVD-202112-2398" }, { "db": "NVD", "id": "CVE-2021-45602" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45602" }, { "date": "2023-01-06T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017181" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2398" }, { "date": "2021-12-26T01:15:17.803000", "db": "NVD", "id": "CVE-2021-45602" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-06T00:00:00", "db": "VULMON", "id": "CVE-2021-45602" }, { "date": "2023-01-06T06:33:00", "db": "JVNDB", "id": "JVNDB-2021-017181" }, { "date": "2022-07-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2398" }, { "date": "2024-11-21T06:32:38.330000", "db": "NVD", "id": "CVE-2021-45602" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2398" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 On the device \u00a0OS\u00a0 Command injection vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017181" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "operating system commend injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2398" } ], "trust": 0.6 } }
var-202112-2400
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.60, DM200 before 1.0.0.66, EX2700 before 1.0.1.56, EX6150v2 before 1.0.1.86, EX6200v2 before 1.0.1.86, EX6250 before 1.0.0.128, EX6400 before 1.0.2.144, EX6400v2 before 1.0.0.128, EX6410 before 1.0.0.128, EX6420 before 1.0.0.128, EX7300 before 1.0.2.144, EX7300v2 before 1.0.0.128, EX7320 before 1.0.0.128, R7500v2 before 1.0.3.46, R7800 before 1.0.2.74, R8900 before 1.0.5.26, R9000 before 1.0.5.2, RAX120 before 1.0.1.128, WN3000RPv2 before 1.0.0.78, WN3000RPv3 before 1.0.2.80, WNR2000v5 before 1.0.0.74, XR500 before 2.3.2.66, RBK20 before 2.7.3.22, RBR20 before 2.7.3.22, RBS20 before 2.7.3.22, RBK40 before 2.7.3.22, RBR40 before 2.7.3.22, and RBS40 before 2.7.3.22. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects D7800 prior to 1.0.1.60, DM200 prior to 1.0.0.66, EX2700 prior to 1.0.1.56, EX6150v2 prior to 1.0.1.86, EX6200v2 prior to 1.0.1.86, EX6250 prior to 1.0.0.128, EX6400 prior to 1.0.2.144, EX6400v2 prior to 1.0.0.128, EX6410 prior to 1.0.0.128, EX6420 prior to 1.0.0.128, EX7300 prior to 1.0.2.144, EX7300v2 prior to 1.0.0.128, EX7320 prior to 1.0.0.128, R7500v2 prior to 1.0.3.46, R7800 prior to 1.0.2.74, R8900 prior to 1.0.5.26, R9000 prior to 1.0.5.2, RAX120 prior to 1.0.1.128, WN3000RPv2 prior to 1.0.0.78, WN3000RPv3 prior to 1.0.2.80, WNR2000v5 prior to 1.0.0.74, XR500 prior to 2.3.2.66, RBK20 prior to 2.7.3.22, RBR20 prior to 2.7.3.22, RBS20 prior to 2.7.3.22, RBK40 prior to 2.7.3.22, RBR40 prior to 2.7.3.22, and RBS40 prior to 2.7.3.22
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2400", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ex2700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.56" }, { "model": "rbr20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.7.3.22" }, { "model": "ex6200v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.86" }, { "model": "ex6410", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.128" }, { "model": "ex7300v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.128" }, { "model": "rax120", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.128" }, { "model": "ex6400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.144" }, { "model": "d7800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.60" }, { "model": "rbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.7.3.22" }, { "model": "ex6400v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.128" }, { "model": "ex6250", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.128" }, { "model": "wn3000rpv2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.78" }, { "model": "ex6150v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.86" }, { "model": "rbk20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.7.3.22" }, { "model": "rbs20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.7.3.22" }, { "model": "rbk40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.7.3.22" }, { "model": "wn3000rpv3", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.80" }, { "model": "ex7320", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.128" }, { "model": "ex7300", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.144" }, { "model": "ex6420", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.128" }, { "model": "wnr2000v5", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.74" }, { "model": "r7500v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.46" }, { "model": "r7800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.74" }, { "model": "xr500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.2.66" }, { "model": "dm200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.66" }, { "model": "r9000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.2" }, { "model": "r8900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.26" }, { "model": "rbs40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.7.3.22" }, { "model": "ex6250", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex6150v2", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex6410", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex6200v2", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex6400v2", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex2700", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex6420", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "dm200", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d7800", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex6400", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017289" }, { "db": "NVD", "id": "CVE-2021-45548" } ] }, "cve": "CVE-2021-45548", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "id": "CVE-2021-45548", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2021-45548", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 6.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.8, "id": "CVE-2021-45548", "impactScore": 5.5, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:L", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45548", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-45548", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-45548", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "CVE-2021-45548", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-202112-2364", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017289" }, { "db": "CNNVD", "id": "CNNVD-202112-2364" }, { "db": "NVD", "id": "CVE-2021-45548" }, { "db": "NVD", "id": "CVE-2021-45548" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.60, DM200 before 1.0.0.66, EX2700 before 1.0.1.56, EX6150v2 before 1.0.1.86, EX6200v2 before 1.0.1.86, EX6250 before 1.0.0.128, EX6400 before 1.0.2.144, EX6400v2 before 1.0.0.128, EX6410 before 1.0.0.128, EX6420 before 1.0.0.128, EX7300 before 1.0.2.144, EX7300v2 before 1.0.0.128, EX7320 before 1.0.0.128, R7500v2 before 1.0.3.46, R7800 before 1.0.2.74, R8900 before 1.0.5.26, R9000 before 1.0.5.2, RAX120 before 1.0.1.128, WN3000RPv2 before 1.0.0.78, WN3000RPv3 before 1.0.2.80, WNR2000v5 before 1.0.0.74, XR500 before 2.3.2.66, RBK20 before 2.7.3.22, RBR20 before 2.7.3.22, RBS20 before 2.7.3.22, RBK40 before 2.7.3.22, RBR40 before 2.7.3.22, and RBS40 before 2.7.3.22. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects D7800 prior to 1.0.1.60, DM200 prior to 1.0.0.66, EX2700 prior to 1.0.1.56, EX6150v2 prior to 1.0.1.86, EX6200v2 prior to 1.0.1.86, EX6250 prior to 1.0.0.128, EX6400 prior to 1.0.2.144, EX6400v2 prior to 1.0.0.128, EX6410 prior to 1.0.0.128, EX6420 prior to 1.0.0.128, EX7300 prior to 1.0.2.144, EX7300v2 prior to 1.0.0.128, EX7320 prior to 1.0.0.128, R7500v2 prior to 1.0.3.46, R7800 prior to 1.0.2.74, R8900 prior to 1.0.5.26, R9000 prior to 1.0.5.2, RAX120 prior to 1.0.1.128, WN3000RPv2 prior to 1.0.0.78, WN3000RPv3 prior to 1.0.2.80, WNR2000v5 prior to 1.0.0.74, XR500 prior to 2.3.2.66, RBK20 prior to 2.7.3.22, RBR20 prior to 2.7.3.22, RBS20 prior to 2.7.3.22, RBK40 prior to 2.7.3.22, RBR40 prior to 2.7.3.22, and RBS40 prior to 2.7.3.22", "sources": [ { "db": "NVD", "id": "CVE-2021-45548" }, { "db": "JVNDB", "id": "JVNDB-2021-017289" }, { "db": "VULMON", "id": "CVE-2021-45548" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45548", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017289", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2364", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45548", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45548" }, { "db": "JVNDB", "id": "JVNDB-2021-017289" }, { "db": "CNNVD", "id": "CNNVD-202112-2364" }, { "db": "NVD", "id": "CVE-2021-45548" } ] }, "id": "VAR-202112-2400", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.43956583190476195 }, "last_update_date": "2024-11-23T22:40:38.041000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0Routers,\u00a0Extenders,\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2019-0207", "trust": 0.8, "url": "https://kb.netgear.com/000064450/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2019-0207" }, { "title": "Netgear NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=176377" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017289" }, { "db": "CNNVD", "id": "CNNVD-202112-2364" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017289" }, { "db": "NVD", "id": "CVE-2021-45548" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064450/security-advisory-for-post-authentication-command-injection-on-some-routers-extenders-and-wifi-systems-psv-2019-0207" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45548" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45548" }, { "db": "JVNDB", "id": "JVNDB-2021-017289" }, { "db": "CNNVD", "id": "CNNVD-202112-2364" }, { "db": "NVD", "id": "CVE-2021-45548" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45548" }, { "db": "JVNDB", "id": "JVNDB-2021-017289" }, { "db": "CNNVD", "id": "CNNVD-202112-2364" }, { "db": "NVD", "id": "CVE-2021-45548" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45548" }, { "date": "2023-01-13T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017289" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2364" }, { "date": "2021-12-26T01:15:15.273000", "db": "NVD", "id": "CVE-2021-45548" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-27T00:00:00", "db": "VULMON", "id": "CVE-2021-45548" }, { "date": "2023-01-13T05:03:00", "db": "JVNDB", "id": "JVNDB-2021-017289" }, { "date": "2022-01-11T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2364" }, { "date": "2024-11-21T06:32:29.167000", "db": "NVD", "id": "CVE-2021-45548" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2364" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017289" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2364" } ], "trust": 0.6 } }
var-202112-2309
Vulnerability from variot
Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D3600 before 1.0.0.72, D6000 before 1.0.0.72, D6200 before 1.1.00.34, D6220 before 1.0.0.52, D6400 before 1.0.0.86, D7000 before 1.0.1.74, D7000v2 before 1.0.0.53, D7800 before 1.0.1.56, D8500 before 1.0.3.44, DC112A before 1.0.0.42, DGN2200v4 before 1.0.0.110, DGND2200Bv4 before 1.0.0.109, DM200 before 1.0.0.61, EX3700 before 1.0.0.76, EX3800 before 1.0.0.76, EX6120 before 1.0.0.46, EX6130 before 1.0.0.28, EX7000 before 1.0.1.78, PR2000 before 1.0.0.28, R6220 before 1.1.0.100, R6230 before 1.1.0.100, R6250 before 1.0.4.34, R6300v2 before 1.0.4.34, R6400 before 1.0.1.46, R6400v2 before 1.0.2.66, R6700 before 1.0.2.6, R6700v3 before 1.0.2.66, R6900 before 1.0.2.6, R7000 before 1.0.9.34, R7100LG before 1.0.0.50, R7500v2 before 1.0.3.40, R7900P before 1.4.1.50, R8000P before 1.4.1.50, R8900 before 1.0.4.12, R9000 before 1.0.4.12, RBK20 before 2.3.0.28, RBK40 before 2.3.0.28, RBK50 before 2.3.0.32, RBR20 before 2.3.0.28, RBR40 before 2.3.0.28, RBR50 before 2.3.0.32, RBS20 before 2.3.0.28, RBS40 before 2.3.0.28, RBS50 before 2.3.0.32, WN3000RPv2 before 1.0.0.78, WNDR3400v3 before 1.0.1.24, WNR2000v5 before 1.0.0.70, WNR2020 before 1.1.0.62, WNR3500Lv2 before 1.2.0.62, XR450 before 2.3.2.56, and XR500 before 2.3.2.56. plural NETGEAR There is an unspecified vulnerability in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects D3600 prior to 1.0.0.72, D6000 prior to 1.0.0.72, D6200 prior to 1.1.00.34, D6220 prior to 1.0.0.52, D6400 prior to 1.0.0.86, D7000 prior to 1.0.1.74, D7000v2 prior to 1.0.0.53, D7800 prior to 1.0.1.56, D8500 prior to 1.0.3.44, DC112A prior to 1.0.0.42, DGN2200v4 prior to 1.0.0.110, DGND2200Bv4 prior to 1.0.0.109, DM200 prior to 1.0.0.61, EX3700 prior to 1.0.0.76, EX3800 prior to 1.0.0.76, EX6120 prior to 1.0.0.46, EX6130 prior to 1.0.0.28, EX7000 prior to 1.0.1.78, PR2000 prior to 1.0.0.28, R6220 prior to 1.1.0.100, R6230 prior to 1.1.0.100, R6250 prior to 1.0.4.34, R6300v2 prior to 1.0.4.34, R6400 prior to 1.0.1.46, R6400v2 prior to 1.0.2.66, R6700 prior to 1.0.2.6, R6700v3 prior to 1.0.2.66, R6900 prior to 1.0.2.6, R7000 prior to 1.0.9.34, R7100LG prior to 1.0.0.50, R7500v2 prior to 1.0.3.40, R7900P prior to 1.4.1.50, R8000P prior to 1.4.1.50, R8900 prior to 1.0.4.12, R9000 prior to 1.0.4.12, RBK20 prior to 2.3.0.28, RBK40 prior to 2.3.0.28, RBK50 prior to 2.3.0.32, RBR20 prior to 2.3.0.28, RBR40 prior to 2.3.0.28, RBR50 prior to 2.3.0.32, RBS20 prior to 2.3.0.28, RBS40 prior to 2.3.0.28, RBS50 prior to 2.3.0.32, WN3000RPv2 prior to 1.0.0.78, WNDR3400v3 prior to 1.0.1.24, WNR2000v5 prior to 1.0.0.70, WNR2020 prior to 1.1.0.62, WNR3500Lv2 prior to 1.2.0.62, XR450 prior to 2.3.2.56, and XR500 prior to 2.3.2.56
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2309", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ex3800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.76" }, { "model": "dc112a", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.42" }, { "model": "r9000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.12" }, { "model": "rbr20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.28" }, { "model": "d6000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.72" }, { "model": "pr2000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.28" }, { "model": "r6400v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.66" }, { "model": "wn3000rpv2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.78" }, { "model": "d6200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.00.34" }, { "model": "wnr2020", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.0.62" }, { "model": "ex7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.78" }, { "model": "dm200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.61" }, { "model": "d3600", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.72" }, { "model": "dgn2200bv4", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.109" }, { "model": "r8000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.50" }, { "model": "rbk40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.28" }, { "model": "rbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.28" }, { "model": "rbk20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.28" }, { "model": "r7900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.50" }, { "model": "rbs20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.28" }, { "model": "dgn2200v4", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.110" }, { "model": "r7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.9.34" }, { "model": "ex3700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.76" }, { "model": "d6220", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.52" }, { "model": "d7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.74" }, { "model": "xr500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.2.56" }, { "model": "r6900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.6" }, { "model": "r6300v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.34" }, { "model": "r6220", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.0.100" }, { "model": "r7500v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.40" }, { "model": "ex6130", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.28" }, { "model": "r6250", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.34" }, { "model": "r8900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.12" }, { "model": "rbs40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.28" }, { "model": "wndr3400v3", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.24" }, { "model": "xr450", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.2.56" }, { "model": "wnr2000v5", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.70" }, { "model": "rbs50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.32" }, { "model": "d7800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.56" }, { "model": "rbk50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.32" }, { "model": "r6700v3", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.66" }, { "model": "ex6120", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.46" }, { "model": "r6700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.6" }, { "model": "d8500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.44" }, { "model": "r7100lg", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.50" }, { "model": "d7000v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.53" }, { "model": "r6400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.46" }, { "model": "d6400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.86" }, { "model": "r6230", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.0.100" }, { "model": "wnr3500lv2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.62" }, { "model": "rbr50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.32" }, { "model": "d8500", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d6200", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d7800", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d7000", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d3600", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "dc112a", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d6400", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d7000v2", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d6000", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d6220", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017516" }, { "db": "NVD", "id": "CVE-2021-45640" } ] }, "cve": "CVE-2021-45640", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "id": "CVE-2021-45640", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.2, "id": "CVE-2021-45640", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "HIGH", "attackVector": "ADJACENT", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 3.9, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "exploitabilityScore": 0.5, "id": "CVE-2021-45640", "impactScore": 3.4, "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.2, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45640", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-45640", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-45640", "trust": 1.0, "value": "LOW" }, { "author": "NVD", "id": "CVE-2021-45640", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-202112-2436", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017516" }, { "db": "CNNVD", "id": "CNNVD-202112-2436" }, { "db": "NVD", "id": "CVE-2021-45640" }, { "db": "NVD", "id": "CVE-2021-45640" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D3600 before 1.0.0.72, D6000 before 1.0.0.72, D6200 before 1.1.00.34, D6220 before 1.0.0.52, D6400 before 1.0.0.86, D7000 before 1.0.1.74, D7000v2 before 1.0.0.53, D7800 before 1.0.1.56, D8500 before 1.0.3.44, DC112A before 1.0.0.42, DGN2200v4 before 1.0.0.110, DGND2200Bv4 before 1.0.0.109, DM200 before 1.0.0.61, EX3700 before 1.0.0.76, EX3800 before 1.0.0.76, EX6120 before 1.0.0.46, EX6130 before 1.0.0.28, EX7000 before 1.0.1.78, PR2000 before 1.0.0.28, R6220 before 1.1.0.100, R6230 before 1.1.0.100, R6250 before 1.0.4.34, R6300v2 before 1.0.4.34, R6400 before 1.0.1.46, R6400v2 before 1.0.2.66, R6700 before 1.0.2.6, R6700v3 before 1.0.2.66, R6900 before 1.0.2.6, R7000 before 1.0.9.34, R7100LG before 1.0.0.50, R7500v2 before 1.0.3.40, R7900P before 1.4.1.50, R8000P before 1.4.1.50, R8900 before 1.0.4.12, R9000 before 1.0.4.12, RBK20 before 2.3.0.28, RBK40 before 2.3.0.28, RBK50 before 2.3.0.32, RBR20 before 2.3.0.28, RBR40 before 2.3.0.28, RBR50 before 2.3.0.32, RBS20 before 2.3.0.28, RBS40 before 2.3.0.28, RBS50 before 2.3.0.32, WN3000RPv2 before 1.0.0.78, WNDR3400v3 before 1.0.1.24, WNR2000v5 before 1.0.0.70, WNR2020 before 1.1.0.62, WNR3500Lv2 before 1.2.0.62, XR450 before 2.3.2.56, and XR500 before 2.3.2.56. plural NETGEAR There is an unspecified vulnerability in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects D3600 prior to 1.0.0.72, D6000 prior to 1.0.0.72, D6200 prior to 1.1.00.34, D6220 prior to 1.0.0.52, D6400 prior to 1.0.0.86, D7000 prior to 1.0.1.74, D7000v2 prior to 1.0.0.53, D7800 prior to 1.0.1.56, D8500 prior to 1.0.3.44, DC112A prior to 1.0.0.42, DGN2200v4 prior to 1.0.0.110, DGND2200Bv4 prior to 1.0.0.109, DM200 prior to 1.0.0.61, EX3700 prior to 1.0.0.76, EX3800 prior to 1.0.0.76, EX6120 prior to 1.0.0.46, EX6130 prior to 1.0.0.28, EX7000 prior to 1.0.1.78, PR2000 prior to 1.0.0.28, R6220 prior to 1.1.0.100, R6230 prior to 1.1.0.100, R6250 prior to 1.0.4.34, R6300v2 prior to 1.0.4.34, R6400 prior to 1.0.1.46, R6400v2 prior to 1.0.2.66, R6700 prior to 1.0.2.6, R6700v3 prior to 1.0.2.66, R6900 prior to 1.0.2.6, R7000 prior to 1.0.9.34, R7100LG prior to 1.0.0.50, R7500v2 prior to 1.0.3.40, R7900P prior to 1.4.1.50, R8000P prior to 1.4.1.50, R8900 prior to 1.0.4.12, R9000 prior to 1.0.4.12, RBK20 prior to 2.3.0.28, RBK40 prior to 2.3.0.28, RBK50 prior to 2.3.0.32, RBR20 prior to 2.3.0.28, RBR40 prior to 2.3.0.28, RBR50 prior to 2.3.0.32, RBS20 prior to 2.3.0.28, RBS40 prior to 2.3.0.28, RBS50 prior to 2.3.0.32, WN3000RPv2 prior to 1.0.0.78, WNDR3400v3 prior to 1.0.1.24, WNR2000v5 prior to 1.0.0.70, WNR2020 prior to 1.1.0.62, WNR3500Lv2 prior to 1.2.0.62, XR450 prior to 2.3.2.56, and XR500 prior to 2.3.2.56", "sources": [ { "db": "NVD", "id": "CVE-2021-45640" }, { "db": "JVNDB", "id": "JVNDB-2021-017516" }, { "db": "VULMON", "id": "CVE-2021-45640" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45640", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017516", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2436", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45640", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45640" }, { "db": "JVNDB", "id": "JVNDB-2021-017516" }, { "db": "CNNVD", "id": "CNNVD-202112-2436" }, { "db": "NVD", "id": "CVE-2021-45640" } ] }, "id": "VAR-202112-2309", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.43955887916666675 }, "last_update_date": "2024-11-23T23:00:59.703000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Security\u00a0Misconfiguration\u00a0on\u00a0Some\u00a0Routers,\u00a0Extenders,\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2018-0228", "trust": 0.8, "url": "https://kb.netgear.com/000064045/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2018-0228" }, { "title": "Netgear NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=176674" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017516" }, { "db": "CNNVD", "id": "CNNVD-202112-2436" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017516" }, { "db": "NVD", "id": "CVE-2021-45640" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064045/security-advisory-for-security-misconfiguration-on-some-routers-extenders-and-wifi-systems-psv-2018-0228" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45640" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45640" }, { "db": "JVNDB", "id": "JVNDB-2021-017516" }, { "db": "CNNVD", "id": "CNNVD-202112-2436" }, { "db": "NVD", "id": "CVE-2021-45640" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45640" }, { "db": "JVNDB", "id": "JVNDB-2021-017516" }, { "db": "CNNVD", "id": "CNNVD-202112-2436" }, { "db": "NVD", "id": "CVE-2021-45640" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45640" }, { "date": "2023-01-24T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017516" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2436" }, { "date": "2021-12-26T01:15:19.643000", "db": "NVD", "id": "CVE-2021-45640" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-27T00:00:00", "db": "VULMON", "id": "CVE-2021-45640" }, { "date": "2023-01-24T05:26:00", "db": "JVNDB", "id": "JVNDB-2021-017516" }, { "date": "2022-01-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2436" }, { "date": "2024-11-21T06:32:45.090000", "db": "NVD", "id": "CVE-2021-45640" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2436" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017516" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2436" } ], "trust": 0.6 } }
cve-2021-45548
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:39:21.551Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064450/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2019-0207" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.60, DM200 before 1.0.0.66, EX2700 before 1.0.1.56, EX6150v2 before 1.0.1.86, EX6200v2 before 1.0.1.86, EX6250 before 1.0.0.128, EX6400 before 1.0.2.144, EX6400v2 before 1.0.0.128, EX6410 before 1.0.0.128, EX6420 before 1.0.0.128, EX7300 before 1.0.2.144, EX7300v2 before 1.0.0.128, EX7320 before 1.0.0.128, R7500v2 before 1.0.3.46, R7800 before 1.0.2.74, R8900 before 1.0.5.26, R9000 before 1.0.5.2, RAX120 before 1.0.1.128, WN3000RPv2 before 1.0.0.78, WN3000RPv3 before 1.0.2.80, WNR2000v5 before 1.0.0.74, XR500 before 2.3.2.66, RBK20 before 2.7.3.22, RBR20 before 2.7.3.22, RBS20 before 2.7.3.22, RBK40 before 2.7.3.22, RBR40 before 2.7.3.22, and RBS40 before 2.7.3.22." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "LOW", "baseScore": 6.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:L/A:L/C:H/I:H/PR:H/S:U/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:52:37", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064450/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2019-0207" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45548", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.60, DM200 before 1.0.0.66, EX2700 before 1.0.1.56, EX6150v2 before 1.0.1.86, EX6200v2 before 1.0.1.86, EX6250 before 1.0.0.128, EX6400 before 1.0.2.144, EX6400v2 before 1.0.0.128, EX6410 before 1.0.0.128, EX6420 before 1.0.0.128, EX7300 before 1.0.2.144, EX7300v2 before 1.0.0.128, EX7320 before 1.0.0.128, R7500v2 before 1.0.3.46, R7800 before 1.0.2.74, R8900 before 1.0.5.26, R9000 before 1.0.5.2, RAX120 before 1.0.1.128, WN3000RPv2 before 1.0.0.78, WN3000RPv3 before 1.0.2.80, WNR2000v5 before 1.0.0.74, XR500 before 2.3.2.66, RBK20 before 2.7.3.22, RBR20 before 2.7.3.22, RBS20 before 2.7.3.22, RBK40 before 2.7.3.22, RBR40 before 2.7.3.22, and RBS40 before 2.7.3.22." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:L/A:L/C:H/I:H/PR:H/S:U/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064450/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2019-0207", "refsource": "MISC", "url": "https://kb.netgear.com/000064450/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2019-0207" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45548", "datePublished": "2021-12-26T00:52:37", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:39:21.551Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45658
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.959Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064062/Security-Advisory-for-Server-Side-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2019-0125" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by server-side injection. This affects D7800 before 1.0.1.58, DM200 before 1.0.0.66, EX2700 before 1.0.1.56, EX6150v2 before 1.0.1.86, EX6100v2 before 1.0.1.86, EX6200v2 before 1.0.1.78, EX6250 before 1.0.0.110, EX6410 before 1.0.0.110, EX6420 before 1.0.0.110, EX6400v2 before 1.0.0.110, EX7300 before 1.0.2.144, EX6400 before 1.0.2.144, EX7320 before 1.0.0.110, EX7300v2 before 1.0.0.110, R7500v2 before 1.0.3.48, R7800 before 1.0.2.68, R8900 before 1.0.5.2, R9000 before 1.0.5.2, RAX120 before 1.0.1.90, RBK40 before 2.5.1.16, RBK20 before 2.5.1.16, RBR20 before 2.5.1.16, RBS20 before 2.5.1.16, RBK50 before 2.5.1.16, RBR50 before 2.5.1.16, RBS50 before 2.5.1.16, RBS50Y before 2.6.1.40, WN3000RPv2 before 1.0.0.78, WN3000RPv3 before 1.0.2.80, WNR2000v5 before 1.0.0.72, XR500 before 2.3.2.56, and XR700 before 1.0.1.20." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:L/A:N/C:H/I:H/PR:L/S:U/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:27:48", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064062/Security-Advisory-for-Server-Side-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2019-0125" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45658", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by server-side injection. This affects D7800 before 1.0.1.58, DM200 before 1.0.0.66, EX2700 before 1.0.1.56, EX6150v2 before 1.0.1.86, EX6100v2 before 1.0.1.86, EX6200v2 before 1.0.1.78, EX6250 before 1.0.0.110, EX6410 before 1.0.0.110, EX6420 before 1.0.0.110, EX6400v2 before 1.0.0.110, EX7300 before 1.0.2.144, EX6400 before 1.0.2.144, EX7320 before 1.0.0.110, EX7300v2 before 1.0.0.110, R7500v2 before 1.0.3.48, R7800 before 1.0.2.68, R8900 before 1.0.5.2, R9000 before 1.0.5.2, RAX120 before 1.0.1.90, RBK40 before 2.5.1.16, RBK20 before 2.5.1.16, RBR20 before 2.5.1.16, RBS20 before 2.5.1.16, RBK50 before 2.5.1.16, RBR50 before 2.5.1.16, RBS50 before 2.5.1.16, RBS50Y before 2.6.1.40, WN3000RPv2 before 1.0.0.78, WN3000RPv3 before 1.0.2.80, WNR2000v5 before 1.0.0.72, XR500 before 2.3.2.56, and XR700 before 1.0.1.20." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:L/A:N/C:H/I:H/PR:L/S:U/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064062/Security-Advisory-for-Server-Side-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2019-0125", "refsource": "MISC", "url": "https://kb.netgear.com/000064062/Security-Advisory-for-Server-Side-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2019-0125" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45658", "datePublished": "2021-12-26T00:27:48", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.959Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-35808
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T17:09:15.189Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000062708/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-and-Range-Extenders-PSV-2018-0158" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by stored XSS. This affects D6100 before 1.0.0.63, DM200 before 1.0.0.61, R7800 before 1.0.2.52, R8900 before 1.0.4.12, R9000 before 1.0.4.12, WN3000RPv2 before 1.0.0.68, and WNR2000v5 before 1.0.0.66." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:N/C:L/I:L/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-12-29T23:36:56", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000062708/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-and-Range-Extenders-PSV-2018-0158" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-35808", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by stored XSS. This affects D6100 before 1.0.0.63, DM200 before 1.0.0.61, R7800 before 1.0.2.52, R8900 before 1.0.4.12, R9000 before 1.0.4.12, WN3000RPv2 before 1.0.0.68, and WNR2000v5 before 1.0.0.66." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "NONE", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:N/C:L/I:L/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000062708/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-and-Range-Extenders-PSV-2018-0158", "refsource": "MISC", "url": "https://kb.netgear.com/000062708/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-and-Range-Extenders-PSV-2018-0158" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-35808", "datePublished": "2020-12-29T23:36:56", "dateReserved": "2020-12-29T00:00:00", "dateUpdated": "2024-08-04T17:09:15.189Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45640
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.875Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064045/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2018-0228" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D3600 before 1.0.0.72, D6000 before 1.0.0.72, D6200 before 1.1.00.34, D6220 before 1.0.0.52, D6400 before 1.0.0.86, D7000 before 1.0.1.74, D7000v2 before 1.0.0.53, D7800 before 1.0.1.56, D8500 before 1.0.3.44, DC112A before 1.0.0.42, DGN2200v4 before 1.0.0.110, DGND2200Bv4 before 1.0.0.109, DM200 before 1.0.0.61, EX3700 before 1.0.0.76, EX3800 before 1.0.0.76, EX6120 before 1.0.0.46, EX6130 before 1.0.0.28, EX7000 before 1.0.1.78, PR2000 before 1.0.0.28, R6220 before 1.1.0.100, R6230 before 1.1.0.100, R6250 before 1.0.4.34, R6300v2 before 1.0.4.34, R6400 before 1.0.1.46, R6400v2 before 1.0.2.66, R6700 before 1.0.2.6, R6700v3 before 1.0.2.66, R6900 before 1.0.2.6, R7000 before 1.0.9.34, R7100LG before 1.0.0.50, R7500v2 before 1.0.3.40, R7900P before 1.4.1.50, R8000P before 1.4.1.50, R8900 before 1.0.4.12, R9000 before 1.0.4.12, RBK20 before 2.3.0.28, RBK40 before 2.3.0.28, RBK50 before 2.3.0.32, RBR20 before 2.3.0.28, RBR40 before 2.3.0.28, RBR50 before 2.3.0.32, RBS20 before 2.3.0.28, RBS40 before 2.3.0.28, RBS50 before 2.3.0.32, WN3000RPv2 before 1.0.0.78, WNDR3400v3 before 1.0.1.24, WNR2000v5 before 1.0.0.70, WNR2020 before 1.1.0.62, WNR3500Lv2 before 1.2.0.62, XR450 before 2.3.2.56, and XR500 before 2.3.2.56." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 3.9, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:H/AV:A/A:L/C:L/I:L/PR:H/S:U/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:31:04", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064045/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2018-0228" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45640", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D3600 before 1.0.0.72, D6000 before 1.0.0.72, D6200 before 1.1.00.34, D6220 before 1.0.0.52, D6400 before 1.0.0.86, D7000 before 1.0.1.74, D7000v2 before 1.0.0.53, D7800 before 1.0.1.56, D8500 before 1.0.3.44, DC112A before 1.0.0.42, DGN2200v4 before 1.0.0.110, DGND2200Bv4 before 1.0.0.109, DM200 before 1.0.0.61, EX3700 before 1.0.0.76, EX3800 before 1.0.0.76, EX6120 before 1.0.0.46, EX6130 before 1.0.0.28, EX7000 before 1.0.1.78, PR2000 before 1.0.0.28, R6220 before 1.1.0.100, R6230 before 1.1.0.100, R6250 before 1.0.4.34, R6300v2 before 1.0.4.34, R6400 before 1.0.1.46, R6400v2 before 1.0.2.66, R6700 before 1.0.2.6, R6700v3 before 1.0.2.66, R6900 before 1.0.2.6, R7000 before 1.0.9.34, R7100LG before 1.0.0.50, R7500v2 before 1.0.3.40, R7900P before 1.4.1.50, R8000P before 1.4.1.50, R8900 before 1.0.4.12, R9000 before 1.0.4.12, RBK20 before 2.3.0.28, RBK40 before 2.3.0.28, RBK50 before 2.3.0.32, RBR20 before 2.3.0.28, RBR40 before 2.3.0.28, RBR50 before 2.3.0.32, RBS20 before 2.3.0.28, RBS40 before 2.3.0.28, RBS50 before 2.3.0.32, WN3000RPv2 before 1.0.0.78, WNDR3400v3 before 1.0.1.24, WNR2000v5 before 1.0.0.70, WNR2020 before 1.1.0.62, WNR3500Lv2 before 1.2.0.62, XR450 before 2.3.2.56, and XR500 before 2.3.2.56." } ] }, "impact": { "cvss": { "attackComplexity": "HIGH", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:H/AV:A/A:L/C:L/I:L/PR:H/S:U/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064045/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2018-0228", "refsource": "MISC", "url": "https://kb.netgear.com/000064045/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2018-0228" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45640", "datePublished": "2021-12-26T00:31:04", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.875Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-35799
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T17:09:15.219Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000062709/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-Range-Extenders-and-WiFi-Systems-PSV-2018-0296" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.76, D6000 before 1.0.0.78, D6200 before 1.1.00.32, D7000 before 1.0.1.68, D7800 before 1.0.1.56, DM200 before 1.0.0.61, EX2700 before 1.0.1.52, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.74, EX6400 before 1.0.2.140, EX7300 before 1.0.2.140, EX8000 before 1.0.1.186, JR6150 before 1.0.1.18, PR2000 before 1.0.0.28, R6020 before 1.0.0.38, R6050 before 1.0.1.18, R6080 before 1.0.0.38, R6120 before 1.0.0.46, R6220 before 1.1.0.80, R6230 before 1.1.0.80, R6260 before 1.1.0.40, R6700v2 before 1.2.0.36, R6800 before 1.2.0.36, R6900v2 before 1.2.0.36, R7500v2 before 1.0.3.40, R7800 before 1.0.2.62, R8900 before 1.0.4.12, R9000 before 1.0.4.12, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK40 before 2.3.0.28, RBR40 before 2.3.0.28, RBS40 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, WN2000RPTv3 before 1.0.1.34, WN3000RPv2 before 1.0.0.78, WN3000RPv2 before 1.0.0.78, WN3000RPv3 before 1.0.2.78, WN3100RPv2 before 1.0.0.66, WNR2000v5 before 1.0.0.70, WNR2020 before 1.1.0.62, XR450 before 2.3.2.32, and XR500 before 2.3.2.32." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-12-29T23:38:28", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000062709/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-Range-Extenders-and-WiFi-Systems-PSV-2018-0296" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-35799", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.76, D6000 before 1.0.0.78, D6200 before 1.1.00.32, D7000 before 1.0.1.68, D7800 before 1.0.1.56, DM200 before 1.0.0.61, EX2700 before 1.0.1.52, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.74, EX6400 before 1.0.2.140, EX7300 before 1.0.2.140, EX8000 before 1.0.1.186, JR6150 before 1.0.1.18, PR2000 before 1.0.0.28, R6020 before 1.0.0.38, R6050 before 1.0.1.18, R6080 before 1.0.0.38, R6120 before 1.0.0.46, R6220 before 1.1.0.80, R6230 before 1.1.0.80, R6260 before 1.1.0.40, R6700v2 before 1.2.0.36, R6800 before 1.2.0.36, R6900v2 before 1.2.0.36, R7500v2 before 1.0.3.40, R7800 before 1.0.2.62, R8900 before 1.0.4.12, R9000 before 1.0.4.12, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK40 before 2.3.0.28, RBR40 before 2.3.0.28, RBS40 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, WN2000RPTv3 before 1.0.1.34, WN3000RPv2 before 1.0.0.78, WN3000RPv2 before 1.0.0.78, WN3000RPv3 before 1.0.2.78, WN3100RPv2 before 1.0.0.66, WNR2000v5 before 1.0.0.70, WNR2020 before 1.1.0.62, XR450 before 2.3.2.32, and XR500 before 2.3.2.32." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000062709/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-Range-Extenders-and-WiFi-Systems-PSV-2018-0296", "refsource": "MISC", "url": "https://kb.netgear.com/000062709/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-Range-Extenders-and-WiFi-Systems-PSV-2018-0296" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-35799", "datePublished": "2020-12-29T23:38:28", "dateReserved": "2020-12-29T00:00:00", "dateUpdated": "2024-08-04T17:09:15.219Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45603
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:00.858Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://immersivelabs.com/resources/blog/netgear-vulnerabilities-could-put-small-business-routers-at-risk/" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064407/Security-Advisory-for-Post-Authentication-Command-Injection-Sensitive-Information-Disclosure-on-Multiple-Products-PSV-2021-0169-PSV-2021-0171" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of sensitive information. A UPnP request reveals a device\u0027s serial number, which can be used for a password reset. This affects D7800 before 1.0.1.66, EX2700 before 1.0.1.68, WN3000RPv2 before 1.0.0.90, WN3000RPv3 before 1.0.2.100, LBR1020 before 2.6.5.20, LBR20 before 2.6.5.32, R6700AX before 1.0.10.110, R7800 before 1.0.2.86, R8900 before 1.0.5.38, R9000 before 1.0.5.38, RAX10 before 1.0.10.110, RAX120v1 before 1.2.3.28, RAX120v2 before 1.2.3.28, RAX70 before 1.0.10.110, RAX78 before 1.0.10.110, XR450 before 2.3.2.130, XR500 before 2.3.2.130, and XR700 before 1.0.1.46." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "LOW", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:L/A:L/C:H/I:N/PR:L/S:U/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:38:30", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://immersivelabs.com/resources/blog/netgear-vulnerabilities-could-put-small-business-routers-at-risk/" }, { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064407/Security-Advisory-for-Post-Authentication-Command-Injection-Sensitive-Information-Disclosure-on-Multiple-Products-PSV-2021-0169-PSV-2021-0171" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45603", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by disclosure of sensitive information. A UPnP request reveals a device\u0027s serial number, which can be used for a password reset. This affects D7800 before 1.0.1.66, EX2700 before 1.0.1.68, WN3000RPv2 before 1.0.0.90, WN3000RPv3 before 1.0.2.100, LBR1020 before 2.6.5.20, LBR20 before 2.6.5.32, R6700AX before 1.0.10.110, R7800 before 1.0.2.86, R8900 before 1.0.5.38, R9000 before 1.0.5.38, RAX10 before 1.0.10.110, RAX120v1 before 1.2.3.28, RAX120v2 before 1.2.3.28, RAX70 before 1.0.10.110, RAX78 before 1.0.10.110, XR450 before 2.3.2.130, XR500 before 2.3.2.130, and XR700 before 1.0.1.46." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:L/A:L/C:H/I:N/PR:L/S:U/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://immersivelabs.com/resources/blog/netgear-vulnerabilities-could-put-small-business-routers-at-risk/", "refsource": "MISC", "url": "https://immersivelabs.com/resources/blog/netgear-vulnerabilities-could-put-small-business-routers-at-risk/" }, { "name": "https://kb.netgear.com/000064407/Security-Advisory-for-Post-Authentication-Command-Injection-Sensitive-Information-Disclosure-on-Multiple-Products-PSV-2021-0169-PSV-2021-0171", "refsource": "MISC", "url": "https://kb.netgear.com/000064407/Security-Advisory-for-Post-Authentication-Command-Injection-Sensitive-Information-Disclosure-on-Multiple-Products-PSV-2021-0169-PSV-2021-0171" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45603", "datePublished": "2021-12-26T00:38:30", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:00.858Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45602
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:00.867Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://immersivelabs.com/resources/blog/netgear-vulnerabilities-could-put-small-business-routers-at-risk/" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064407/Security-Advisory-for-Post-Authentication-Command-Injection-Sensitive-Information-Disclosure-on-Multiple-Products-PSV-2021-0169-PSV-2021-0171" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.66, EX2700 before 1.0.1.68, WN3000RPv2 before 1.0.0.90, WN3000RPv3 before 1.0.2.100, LBR1020 before 2.6.5.20, LBR20 before 2.6.5.32, R6700AX before 1.0.10.110, R7800 before 1.0.2.86, R8900 before 1.0.5.38, R9000 before 1.0.5.38, RAX10 before 1.0.10.110, RAX120v1 before 1.2.3.28, RAX120v2 before 1.2.3.28, RAX70 before 1.0.10.110, RAX78 before 1.0.10.110, XR450 before 2.3.2.130, XR500 before 2.3.2.130, and XR700 before 1.0.1.46." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "LOW", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:L/A:L/C:H/I:N/PR:L/S:U/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:38:46", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://immersivelabs.com/resources/blog/netgear-vulnerabilities-could-put-small-business-routers-at-risk/" }, { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064407/Security-Advisory-for-Post-Authentication-Command-Injection-Sensitive-Information-Disclosure-on-Multiple-Products-PSV-2021-0169-PSV-2021-0171" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45602", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.66, EX2700 before 1.0.1.68, WN3000RPv2 before 1.0.0.90, WN3000RPv3 before 1.0.2.100, LBR1020 before 2.6.5.20, LBR20 before 2.6.5.32, R6700AX before 1.0.10.110, R7800 before 1.0.2.86, R8900 before 1.0.5.38, R9000 before 1.0.5.38, RAX10 before 1.0.10.110, RAX120v1 before 1.2.3.28, RAX120v2 before 1.2.3.28, RAX70 before 1.0.10.110, RAX78 before 1.0.10.110, XR450 before 2.3.2.130, XR500 before 2.3.2.130, and XR700 before 1.0.1.46." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:L/A:L/C:H/I:N/PR:L/S:U/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://immersivelabs.com/resources/blog/netgear-vulnerabilities-could-put-small-business-routers-at-risk/", "refsource": "MISC", "url": "https://immersivelabs.com/resources/blog/netgear-vulnerabilities-could-put-small-business-routers-at-risk/" }, { "name": "https://kb.netgear.com/000064407/Security-Advisory-for-Post-Authentication-Command-Injection-Sensitive-Information-Disclosure-on-Multiple-Products-PSV-2021-0169-PSV-2021-0171", "refsource": "MISC", "url": "https://kb.netgear.com/000064407/Security-Advisory-for-Post-Authentication-Command-Injection-Sensitive-Information-Disclosure-on-Multiple-Products-PSV-2021-0169-PSV-2021-0171" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45602", "datePublished": "2021-12-26T00:38:46", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:00.867Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-26913
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T16:03:22.712Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000062340/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-WiFi-Systems-PSV-2018-0140" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.63, R7800 before 1.0.2.60, R8900 before 1.0.4.26, R9000 before 1.0.4.26, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, RBK40 before 2.3.0.28, RBR40 before 2.3.0.28, RBS40 before 2.3.0.28, SRK60 before 2.2.2.20, SRR60 before 2.2.2.20, SRS60 before 2.2.2.20, WN3000RPv2 before 1.0.0.78, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.70, XR450 before 2.3.2.40, and XR500 before 2.3.2.40." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-10-09T06:30:57", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000062340/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-WiFi-Systems-PSV-2018-0140" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-26913", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.63, R7800 before 1.0.2.60, R8900 before 1.0.4.26, R9000 before 1.0.4.26, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, RBK40 before 2.3.0.28, RBR40 before 2.3.0.28, RBS40 before 2.3.0.28, SRK60 before 2.2.2.20, SRR60 before 2.2.2.20, SRS60 before 2.2.2.20, WN3000RPv2 before 1.0.0.78, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.70, XR450 before 2.3.2.40, and XR500 before 2.3.2.40." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000062340/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-WiFi-Systems-PSV-2018-0140", "refsource": "MISC", "url": "https://kb.netgear.com/000062340/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-WiFi-Systems-PSV-2018-0140" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-26913", "datePublished": "2020-10-09T06:30:57", "dateReserved": "2020-10-09T00:00:00", "dateUpdated": "2024-08-04T16:03:22.712Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-35806
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T17:09:15.248Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000062729/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-and-Orbi-WiFi-Systems-PSV-2018-0539" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by stored XSS. This affects D7800 before 1.0.1.56, R7500v2 before 1.0.3.46, R7800 before 1.0.2.68, RAX120 before 1.0.0.78, RBK22 before 2.3.5.26, RBR20 before 2.3.5.26, RBS20 before 2.3.5.26, RBK40 before 2.3.5.30, RBR40 before 2.3.5.30, RBS40 before 2.3.5.30, RBK50 before 2.3.5.30, RBR50 before 2.3.5.30, RBS50 before 2.3.5.30, and WN3000RPv2 before 1.0.0.78." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 6, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:L/A:N/C:H/I:H/PR:H/S:U/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-12-29T23:37:12", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000062729/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-and-Orbi-WiFi-Systems-PSV-2018-0539" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-35806", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by stored XSS. This affects D7800 before 1.0.1.56, R7500v2 before 1.0.3.46, R7800 before 1.0.2.68, RAX120 before 1.0.0.78, RBK22 before 2.3.5.26, RBR20 before 2.3.5.26, RBS20 before 2.3.5.26, RBK40 before 2.3.5.30, RBR40 before 2.3.5.30, RBS40 before 2.3.5.30, RBK50 before 2.3.5.30, RBR50 before 2.3.5.30, RBS50 before 2.3.5.30, and WN3000RPv2 before 1.0.0.78." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:L/A:N/C:H/I:H/PR:H/S:U/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000062729/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-and-Orbi-WiFi-Systems-PSV-2018-0539", "refsource": "MISC", "url": "https://kb.netgear.com/000062729/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-and-Orbi-WiFi-Systems-PSV-2018-0539" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-35806", "datePublished": "2020-12-29T23:37:12", "dateReserved": "2020-12-29T00:00:00", "dateUpdated": "2024-08-04T17:09:15.248Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-35807
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T17:09:15.184Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000062730/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-and-Orbi-WiFi-Systems-PSV-2018-0557" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by stored XSS. This affects D7800 before 1.0.1.56, R7800 before 1.0.2.68, RAX120 before 1.0.0.78, RBK22 before 2.3.5.26, RBR20 before 2.3.5.26, RBS20 before 2.3.5.26, RBK40 before 2.3.5.30, RBR40 before 2.3.5.30, RBS40 before 2.3.5.30, RBK50 before 2.3.5.30, RBR50 before 2.3.5.30, RBS50 before 2.3.5.30, and WN3000RPv2 before 1.0.0.78." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 6, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:L/A:N/C:H/I:H/PR:H/S:U/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-12-29T23:37:04", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000062730/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-and-Orbi-WiFi-Systems-PSV-2018-0557" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-35807", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by stored XSS. This affects D7800 before 1.0.1.56, R7800 before 1.0.2.68, RAX120 before 1.0.0.78, RBK22 before 2.3.5.26, RBR20 before 2.3.5.26, RBS20 before 2.3.5.26, RBK40 before 2.3.5.30, RBR40 before 2.3.5.30, RBS40 before 2.3.5.30, RBK50 before 2.3.5.30, RBR50 before 2.3.5.30, RBS50 before 2.3.5.30, and WN3000RPv2 before 1.0.0.78." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:L/A:N/C:H/I:H/PR:H/S:U/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000062730/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-and-Orbi-WiFi-Systems-PSV-2018-0557", "refsource": "MISC", "url": "https://kb.netgear.com/000062730/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-and-Orbi-WiFi-Systems-PSV-2018-0557" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-35807", "datePublished": "2020-12-29T23:37:04", "dateReserved": "2020-12-29T00:00:00", "dateUpdated": "2024-08-04T17:09:15.184Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45641
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.737Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064053/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2018-0624" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D3600 before 1.0.0.72, D6000 before 1.0.0.72, D6200 before 1.1.00.34, D6220 before 1.0.0.52, D6400 before 1.0.0.86, D7000 before 1.0.1.74, D7000v2 before 1.0.0.53, D7800 before 1.0.1.56, D8500 before 1.0.3.44, DC112A before 1.0.0.42, DGN2200Bv4 before 1.0.0.109, DGN2200v4 before 1.0.0.110, DM200 before 1.0.0.61, EX3700 before 1.0.0.76, EX3800 before 1.0.0.76, EX6120 before 1.0.0.46, EX6130 before 1.0.0.28, EX7000 before 1.0.1.78, PR2000 before 1.0.0.28, R6220 before 1.1.0.100, R6230 before 1.1.0.100, R6250 before 1.0.4.34, R6300v2 before 1.0.4.34, R6400 before 1.0.1.46, R6400v2 before 1.0.2.66, R6700v3 before 1.0.2.66, R6700 before 1.0.2.6, R6900 before 1.0.2.6, R7000 before 1.0.9.34, R7100LG before 1.0.0.50, R7500v2 before 1.0.3.40, R7900P before 1.4.1.50, R8000P before 1.4.1.50, R8900 before 1.0.4.12, R9000 before 1.0.4.12, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK40 before 2.3.0.28, RBR40 before 2.3.0.28, RBS40 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, WN3000RPv2 before 1.0.0.78, WNDR3400v3 before 1.0.1.24, WNR2000v5 before 1.0.0.70, WNR2020 before 1.1.0.62, and XR500 before 2.3.2.56." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 4.6, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:N/C:L/I:L/PR:L/S:U/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:30:55", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064053/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2018-0624" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45641", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D3600 before 1.0.0.72, D6000 before 1.0.0.72, D6200 before 1.1.00.34, D6220 before 1.0.0.52, D6400 before 1.0.0.86, D7000 before 1.0.1.74, D7000v2 before 1.0.0.53, D7800 before 1.0.1.56, D8500 before 1.0.3.44, DC112A before 1.0.0.42, DGN2200Bv4 before 1.0.0.109, DGN2200v4 before 1.0.0.110, DM200 before 1.0.0.61, EX3700 before 1.0.0.76, EX3800 before 1.0.0.76, EX6120 before 1.0.0.46, EX6130 before 1.0.0.28, EX7000 before 1.0.1.78, PR2000 before 1.0.0.28, R6220 before 1.1.0.100, R6230 before 1.1.0.100, R6250 before 1.0.4.34, R6300v2 before 1.0.4.34, R6400 before 1.0.1.46, R6400v2 before 1.0.2.66, R6700v3 before 1.0.2.66, R6700 before 1.0.2.6, R6900 before 1.0.2.6, R7000 before 1.0.9.34, R7100LG before 1.0.0.50, R7500v2 before 1.0.3.40, R7900P before 1.4.1.50, R8000P before 1.4.1.50, R8900 before 1.0.4.12, R9000 before 1.0.4.12, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK40 before 2.3.0.28, RBR40 before 2.3.0.28, RBS40 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, WN3000RPv2 before 1.0.0.78, WNDR3400v3 before 1.0.1.24, WNR2000v5 before 1.0.0.70, WNR2020 before 1.1.0.62, and XR500 before 2.3.2.56." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "NONE", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:N/C:L/I:L/PR:L/S:U/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064053/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2018-0624", "refsource": "MISC", "url": "https://kb.netgear.com/000064053/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2018-0624" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45641", "datePublished": "2021-12-26T00:30:55", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.737Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ACEAC1F2-EEAE-4880-B6C0-FFAAA29685F1", "versionEndExcluding": "1.0.1.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dm200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CFD91F26-5253-4A05-AB69-94CB2C416F83", "versionEndExcluding": "1.0.0.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dm200:-:*:*:*:*:*:*:*", "matchCriteriaId": "1B048F71-70F1-4D9F-84E2-9F7340F6ADAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex2700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BDB07B26-FD18-4023-A143-E890076FF68A", "versionEndExcluding": "1.0.1.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex2700:-:*:*:*:*:*:*:*", "matchCriteriaId": "5341B659-DE7D-43F1-954D-82049CBE18AD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6150v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5AC48A9A-9B6B-4E46-A022-958939EB2827", "versionEndExcluding": "1.0.1.86", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6150v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "5828F04B-E373-4E4F-942D-08CCA038418C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6100v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C634416-8822-46D9-B6CA-DE71F4E2BFF1", "versionEndExcluding": "1.0.1.86", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6100v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "4DCFF79A-8ACE-455B-90F3-FFC745E8BAD4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6200v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "35673ECF-BC73-4B7D-9BFD-8A66A55C750A", "versionEndExcluding": "1.0.1.78", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6200v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "2141AE0A-18CB-4142-A850-B2153DAEE5A8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6250_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7A3F4095-4746-4689-8190-13F2734493CC", "versionEndExcluding": "1.0.0.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6250:-:*:*:*:*:*:*:*", "matchCriteriaId": "B7694D0C-2CC6-4A6E-A251-5CBFC67D2AA9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6410_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "95F639EF-A599-4CC7-BDB1-5AF74560ADEB", "versionEndExcluding": "1.0.0.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6410:-:*:*:*:*:*:*:*", "matchCriteriaId": "C63267D8-4632-4D14-B39C-BEEC62AD8F87", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6420_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A1C892CF-A183-45F0-AFEA-1448D93118AE", "versionEndExcluding": "1.0.0.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6420:-:*:*:*:*:*:*:*", "matchCriteriaId": "0B2C00E1-4A23-4304-B92F-B7D9F4818D90", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6400v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "04F2925C-EF25-4162-8A3C-729191AC59D3", "versionEndExcluding": "1.0.0.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6400v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "5882095F-B22A-4937-BA08-6640140F10AE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BC45DE2E-BC27-4710-A237-1EFB4CD06299", "versionEndExcluding": "1.0.2.144", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7300:-:*:*:*:*:*:*:*", "matchCriteriaId": "F285D60D-A5DA-4467-8F79-15EF8135D007", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7C515A99-8AC2-404F-BD64-9043C72EC4EC", "versionEndExcluding": "1.0.2.144", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "1289BBB4-1955-46A4-B5FE-BF11153C24F5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7320_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "568044B5-D287-4355-A375-E260F853AA03", "versionEndExcluding": "1.0.0.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7320:-:*:*:*:*:*:*:*", "matchCriteriaId": "A1D4DF51-84EA-4296-9E06-CE5E1F4A53D1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7300v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A59D262F-1A53-4769-91B4-495217600D76", "versionEndExcluding": "1.0.0.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7300v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "0A88D2A3-3B22-4639-94E9-69CE80F37392", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C745B393-CC8D-4F88-A6EB-2788E1A4BAF9", "versionEndExcluding": "1.0.3.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "2BCA6487-57EC-4630-884F-820BBFE25843", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "70E4DC5E-E34E-4AB1-BD50-F741142CB917", "versionEndExcluding": "1.0.2.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "73ADA144-1E36-4F69-8C2D-2DD000F93361", "versionEndExcluding": "1.0.5.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A3A5762A-D32D-459B-B6CE-C54F8704BDEF", "versionEndExcluding": "1.0.5.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC0EC10D-5D3C-4C1F-83ED-24409A2F0F0E", "versionEndExcluding": "1.0.1.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax120:-:*:*:*:*:*:*:*", "matchCriteriaId": "1742BD56-84E4-40E1-8C04-098B3715161E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3DB57ABF-8ABA-47E0-974D-AF8DF696A968", "versionEndExcluding": "2.5.1.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk40:-:*:*:*:*:*:*:*", "matchCriteriaId": "12DDD83C-6FF1-433F-ACA1-7B4B147F9A8C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AE5AB36A-A020-4604-AB9B-55F114172D8D", "versionEndExcluding": "2.5.1.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk20:-:*:*:*:*:*:*:*", "matchCriteriaId": "E6C9F31C-3E12-4787-9C9B-14883D9D152A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "31604191-2A95-440D-B58B-84066805D623", "versionEndExcluding": "2.5.1.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr20:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE5DBD66-9C2A-4EFF-87AB-03E791D584B5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "87234D9C-235C-49CB-B88C-C2B84007387B", "versionEndExcluding": "2.5.1.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs20:-:*:*:*:*:*:*:*", "matchCriteriaId": "14FC7F5B-7E4F-4A68-8427-D1F553EBE8CA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "70C4C62E-6B4C-4987-A6CA-07903E37EC34", "versionEndExcluding": "2.5.1.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk50:-:*:*:*:*:*:*:*", "matchCriteriaId": "8BA66D07-D017-49D6-8E72-5C48E940DE1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D5C3D18C-1CA3-4082-8F81-03BCE08F88B0", "versionEndExcluding": "2.5.1.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr50:-:*:*:*:*:*:*:*", "matchCriteriaId": "B2CAEA32-6934-4743-9E6B-22D52AC5E7F8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1EA2BB79-FBC6-45FB-B617-7EFCEE57DB73", "versionEndExcluding": "2.5.1.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs50:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BCFD959-D522-4FA0-AD01-2937DAEE1EDF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs50y_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E9E75105-CB35-4983-8CC0-98699AAA63BE", "versionEndExcluding": "2.6.1.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs50y:-:*:*:*:*:*:*:*", "matchCriteriaId": "27F93A76-6EFF-4DA6-9129-4792E2C125D4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rpv2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AA82BFA7-9B98-408C-BE81-E8D7532780A2", "versionEndExcluding": "1.0.0.78", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rpv2:-:*:*:*:*:*:*:*", "matchCriteriaId": "50BC8FA2-F9D5-4286-97DD-BD2A55EA234D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rpv3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "29D544D2-5FF5-4C86-94A9-5562B277ABDC", "versionEndExcluding": "1.0.2.80", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rpv3:-:*:*:*:*:*:*:*", "matchCriteriaId": "958243A2-6829-464F-80EA-7DD5B6F0DD7A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000v5_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "37A3A395-4878-4026-8308-E83DFD66A781", "versionEndExcluding": "1.0.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000v5:-:*:*:*:*:*:*:*", "matchCriteriaId": "671EC923-DC84-47D6-B943-0F7DA8168334", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AA9B22EF-5791-41DB-8CC1-A1B60CF4A73F", "versionEndExcluding": "2.3.2.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr500:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E203D92-F97B-4F5B-B395-3A5DEDBF1C1C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5EAA7899-50E0-40CD-9CB9-877C48E4ED46", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr700:-:*:*:*:*:*:*:*", "matchCriteriaId": "E12892C8-5E01-49A6-BF47-09D630377093", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by server-side injection. This affects D7800 before 1.0.1.58, DM200 before 1.0.0.66, EX2700 before 1.0.1.56, EX6150v2 before 1.0.1.86, EX6100v2 before 1.0.1.86, EX6200v2 before 1.0.1.78, EX6250 before 1.0.0.110, EX6410 before 1.0.0.110, EX6420 before 1.0.0.110, EX6400v2 before 1.0.0.110, EX7300 before 1.0.2.144, EX6400 before 1.0.2.144, EX7320 before 1.0.0.110, EX7300v2 before 1.0.0.110, R7500v2 before 1.0.3.48, R7800 before 1.0.2.68, R8900 before 1.0.5.2, R9000 before 1.0.5.2, RAX120 before 1.0.1.90, RBK40 before 2.5.1.16, RBK20 before 2.5.1.16, RBR20 before 2.5.1.16, RBS20 before 2.5.1.16, RBK50 before 2.5.1.16, RBR50 before 2.5.1.16, RBS50 before 2.5.1.16, RBS50Y before 2.6.1.40, WN3000RPv2 before 1.0.0.78, WN3000RPv3 before 1.0.2.80, WNR2000v5 before 1.0.0.72, XR500 before 2.3.2.56, and XR700 before 1.0.1.20." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por la inyecci\u00f3n en el lado del servidor. Esto afecta al D7800 antes de 1.0.1.58, DM200 antes de 1.0.0.66, EX2700 antes de 1.0.1.56, EX6150v2 antes de 1.0.1.86, EX6100v2 antes de 1.0.1.86, EX6200v2 antes de 1.0.1.78, EX6250 antes de 1.0.0.110, EX6410 antes de 1.0.0.110, EX7300 antes de 1.0.0.110. 0.0.110, EX6420 antes de 1.0.0.110, EX6400v2 antes de 1.0.0.110, EX7300 antes de 1.0.2.144, EX6400 antes de 1.0.2.144, EX7320 antes de 1.0.0.110, EX7300v2 antes de 1.0.0.110, R7500v2 antes de 1.0.3.48, R7800 antes de 1. 0.2.68, R8900 antes de 1.0.5.2, R9000 antes de 1.0.5.2, RAX120 antes de 1.0.1.90, RBK40 antes de 2.5.1.16, RBK20 antes de 2.5.1.16, RBR20 antes de 2.5.1.16, RBS20 antes de 2.5.1.16, RBK50 antes de 2.5.1. 16, RBR50 antes de 2.5.1.16, RBS50 antes de 2.5.1.16, RBS50Y antes de 2.6.1.40, WN3000RPv2 antes de 1.0.0.78, WN3000RPv3 antes de 1.0.2.80, WNR2000v5 antes de 1.0.0.72, XR500 antes de 2.3.2.56 y XR700 antes de 1.0.1.20." } ], "id": "CVE-2021-45658", "lastModified": "2024-11-21T06:32:48.427", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.2, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:20.467", "references": [ { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064062/Security-Advisory-for-Server-Side-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2019-0125" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064062/Security-Advisory-for-Server-Side-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2019-0125" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-74" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
Vendor | Product | Version | |
---|---|---|---|
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | dm200_firmware | * | |
netgear | dm200 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wn3000rpv2_firmware | * | |
netgear | wn3000rpv2 | - | |
netgear | wnr2000v5_firmware | * | |
netgear | wnr2000v5 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8DE5478F-11CE-4730-AC60-64ACE7BBB03A", "versionEndExcluding": "1.0.0.63", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dm200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6B27650A-B7FE-41E4-8231-9283CC7B8349", "versionEndExcluding": "1.0.0.61", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dm200:-:*:*:*:*:*:*:*", "matchCriteriaId": "1B048F71-70F1-4D9F-84E2-9F7340F6ADAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C2195F1-18F6-4397-9D28-7A92003B7A76", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E5AC056A-DF92-4CA7-9919-2C9BDAE3C32D", "versionEndExcluding": "1.0.4.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F1F914AD-70DC-47F5-A2F7-672DBE89C62E", "versionEndExcluding": "1.0.4.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rpv2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0F20A1B5-DBD0-445F-AB0D-30212439FFD4", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rpv2:-:*:*:*:*:*:*:*", "matchCriteriaId": "50BC8FA2-F9D5-4286-97DD-BD2A55EA234D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000v5_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D275B1AC-7E46-4892-9ACB-DEB53543E0B5", "versionEndExcluding": "1.0.0.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000v5:-:*:*:*:*:*:*:*", "matchCriteriaId": "671EC923-DC84-47D6-B943-0F7DA8168334", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by stored XSS. This affects D6100 before 1.0.0.63, DM200 before 1.0.0.61, R7800 before 1.0.2.52, R8900 before 1.0.4.12, R9000 before 1.0.4.12, WN3000RPv2 before 1.0.0.68, and WNR2000v5 before 1.0.0.66." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una vulnerabilidad de tipo XSS almacenado.\u0026#xa0;Esto afecta a D6100 versiones anteriores a 1.0.0.63, DM200 versiones anteriores a 1.0.0.61, R7800 versiones anteriores a 1.0.2.52, R8900 versiones anteriores a 1.0.4.12, R9000 versiones anteriores a 1.0.4.12, WN3000RPv2 versiones anteriores a 1.0.0.68 y WNR2000v5 versiones anteriores a 1.0.0.66." } ], "id": "CVE-2020-35808", "lastModified": "2024-11-21T05:28:10.323", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 3.5, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 6.8, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 2.7, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-12-30T00:15:14.863", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062708/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-and-Range-Extenders-PSV-2018-0158" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062708/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-and-Range-Extenders-PSV-2018-0158" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6CBD5FC4-2EF7-49A9-8F23-C9398441E7BD", "versionEndExcluding": "1.0.1.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dm200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CFD91F26-5253-4A05-AB69-94CB2C416F83", "versionEndExcluding": "1.0.0.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dm200:-:*:*:*:*:*:*:*", "matchCriteriaId": "1B048F71-70F1-4D9F-84E2-9F7340F6ADAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex2700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BDB07B26-FD18-4023-A143-E890076FF68A", "versionEndExcluding": "1.0.1.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex2700:-:*:*:*:*:*:*:*", "matchCriteriaId": "5341B659-DE7D-43F1-954D-82049CBE18AD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6150v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5AC48A9A-9B6B-4E46-A022-958939EB2827", "versionEndExcluding": "1.0.1.86", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6150v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "5828F04B-E373-4E4F-942D-08CCA038418C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6200v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "033E6FD3-A903-438D-88B2-F6AF7B2ECBCE", "versionEndExcluding": "1.0.1.86", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6200v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "2141AE0A-18CB-4142-A850-B2153DAEE5A8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6250_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DB1C84E8-B947-4850-9D66-E306557DC316", "versionEndExcluding": "1.0.0.128", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6250:-:*:*:*:*:*:*:*", "matchCriteriaId": "B7694D0C-2CC6-4A6E-A251-5CBFC67D2AA9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7C515A99-8AC2-404F-BD64-9043C72EC4EC", "versionEndExcluding": "1.0.2.144", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "1289BBB4-1955-46A4-B5FE-BF11153C24F5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6400v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "22C5E2C9-E8DA-478A-B3B1-2C0038B5D560", "versionEndExcluding": "1.0.0.128", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6400v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "5882095F-B22A-4937-BA08-6640140F10AE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6410_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DD3A7D2-75CE-4C67-AAE2-75F09653DFA7", "versionEndExcluding": "1.0.0.128", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6410:-:*:*:*:*:*:*:*", "matchCriteriaId": "C63267D8-4632-4D14-B39C-BEEC62AD8F87", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6420_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "270D7E5A-4680-4F01-ADBA-8A8B7368CBAA", "versionEndExcluding": "1.0.0.128", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6420:-:*:*:*:*:*:*:*", "matchCriteriaId": "0B2C00E1-4A23-4304-B92F-B7D9F4818D90", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BC45DE2E-BC27-4710-A237-1EFB4CD06299", "versionEndExcluding": "1.0.2.144", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7300:-:*:*:*:*:*:*:*", "matchCriteriaId": "F285D60D-A5DA-4467-8F79-15EF8135D007", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7300v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E3B1295F-3207-4DF4-BA5B-0DE7AB289636", "versionEndExcluding": "1.0.0.128", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7300v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "0A88D2A3-3B22-4639-94E9-69CE80F37392", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7320_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0EE4BFF4-42DA-4A09-892E-6FBBE72B28A6", "versionEndExcluding": "1.0.0.128", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7320:-:*:*:*:*:*:*:*", "matchCriteriaId": "A1D4DF51-84EA-4296-9E06-CE5E1F4A53D1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "801B6E47-327F-4C7F-B3BD-CC08F94B19AC", "versionEndExcluding": "1.0.3.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "2BCA6487-57EC-4630-884F-820BBFE25843", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C393DBF4-8281-4611-B591-CDB9DF0AA958", "versionEndExcluding": "1.0.2.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "617156D5-63CB-4533-A816-C7FCA2F1C0EF", "versionEndExcluding": "1.0.5.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A3A5762A-D32D-459B-B6CE-C54F8704BDEF", "versionEndExcluding": "1.0.5.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9B47F077-65E9-4971-975A-357B6CD4017F", "versionEndExcluding": "1.0.1.128", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax120:-:*:*:*:*:*:*:*", "matchCriteriaId": "1742BD56-84E4-40E1-8C04-098B3715161E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rpv2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AA82BFA7-9B98-408C-BE81-E8D7532780A2", "versionEndExcluding": "1.0.0.78", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rpv2:-:*:*:*:*:*:*:*", "matchCriteriaId": "50BC8FA2-F9D5-4286-97DD-BD2A55EA234D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rpv3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "29D544D2-5FF5-4C86-94A9-5562B277ABDC", "versionEndExcluding": "1.0.2.80", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rpv3:-:*:*:*:*:*:*:*", "matchCriteriaId": "958243A2-6829-464F-80EA-7DD5B6F0DD7A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000v5_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E158EE92-A472-447D-BFFE-F2A74674326F", "versionEndExcluding": "1.0.0.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000v5_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "F024A464-DB7D-4F6E-A951-3D8068F86470", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0BCFB551-95C6-4EEF-83F0-4246F67E6668", "versionEndExcluding": "2.3.2.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr500:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E203D92-F97B-4F5B-B395-3A5DEDBF1C1C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A4021DFA-AEBD-4C6C-9793-48171990F8B3", "versionEndExcluding": "2.7.3.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk20:-:*:*:*:*:*:*:*", "matchCriteriaId": "E6C9F31C-3E12-4787-9C9B-14883D9D152A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4E0AC598-D991-49E0-86ED-4ABF0E42E504", "versionEndExcluding": "2.7.3.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr20:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE5DBD66-9C2A-4EFF-87AB-03E791D584B5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3C936668-6B8C-4497-A5A3-7C4B6CADB09B", "versionEndExcluding": "2.7.3.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs20:-:*:*:*:*:*:*:*", "matchCriteriaId": "14FC7F5B-7E4F-4A68-8427-D1F553EBE8CA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CA096BE4-3AE5-4AEA-B4C4-359D3A0C7F1E", "versionEndExcluding": "2.7.3.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk40:-:*:*:*:*:*:*:*", "matchCriteriaId": "12DDD83C-6FF1-433F-ACA1-7B4B147F9A8C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1FD3226E-1B9D-420E-AD7B-7D1DDC867D3F", "versionEndExcluding": "2.7.3.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "A9E20E59-2B1E-4E43-A494-2C20FD716D4F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "40435599-FC79-4563-BF8B-BB1F84BDA82D", "versionEndExcluding": "2.7.3.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40:-:*:*:*:*:*:*:*", "matchCriteriaId": "6FDCDE39-0355-43B9-BF57-F3718DA2988D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.60, DM200 before 1.0.0.66, EX2700 before 1.0.1.56, EX6150v2 before 1.0.1.86, EX6200v2 before 1.0.1.86, EX6250 before 1.0.0.128, EX6400 before 1.0.2.144, EX6400v2 before 1.0.0.128, EX6410 before 1.0.0.128, EX6420 before 1.0.0.128, EX7300 before 1.0.2.144, EX7300v2 before 1.0.0.128, EX7320 before 1.0.0.128, R7500v2 before 1.0.3.46, R7800 before 1.0.2.74, R8900 before 1.0.5.26, R9000 before 1.0.5.2, RAX120 before 1.0.1.128, WN3000RPv2 before 1.0.0.78, WN3000RPv3 before 1.0.2.80, WNR2000v5 before 1.0.0.74, XR500 before 2.3.2.66, RBK20 before 2.7.3.22, RBR20 before 2.7.3.22, RBS20 before 2.7.3.22, RBK40 before 2.7.3.22, RBR40 before 2.7.3.22, and RBS40 before 2.7.3.22." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a D7800 versiones anteriores a 1.0.1.60, DM200 versiones anteriores a 1.0.0.66, EX2700 versiones anteriores a 1.0.1.56, EX6150v2 versiones anteriores a 1.0.1.86, EX6200v2 versiones anteriores a 1.0.1.86, EX6250 versiones anteriores a 1.0.0.128, EX6400 versiones anteriores a 1.0. 2.144, EX6400v2 versiones anteriores a 1.0.0.128, EX6410 versiones anteriores a 1.0.0.128, EX6420 versiones anteriores a 1.0.0.128, EX7300 versiones anteriores a 1.0.2.144, EX7300v2 versiones anteriores a 1.0.0.128, EX7320 versiones anteriores a 1.0.0.128, R7500v2 versiones anteriores a 1. 0.3.46, R7800 versiones anteriores a 1.0.2.74, R8900 versiones anteriores a 1.0.5.26, R9000 versiones anteriores a 1.0.5.2, RAX120 versiones anteriores a 1.0.1.128, WN3000RPv2 versiones anteriores a 1.0.0.78, WN3000RPv3 versiones anteriores a 1.0.2.80, WNR2000v5 versiones anteriores a 1. 0.0.74, XR500 versiones anteriores a 2.3.2.66, RBK20 versiones anteriores a 2.7.3.22, RBR20 versiones anteriores a 2.7.3.22, RBS20 versiones anteriores a 2.7.3.22, RBK40 versiones anteriores a 2.7.3.22, RBR40 versiones anteriores a 2.7.3.22 y RBS40 versiones anteriores a 2.7.3.22" } ], "id": "CVE-2021-45548", "lastModified": "2024-11-21T06:32:29.167", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "LOW", "baseScore": 6.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:L", "version": "3.1" }, "exploitabilityScore": 0.8, "impactScore": 5.5, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:15.273", "references": [ { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064450/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2019-0207" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064450/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2019-0207" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | ex2700_firmware | * | |
netgear | ex2700 | - | |
netgear | wn3000rpv2_firmware | * | |
netgear | wn3000rpv2 | - | |
netgear | wn3000rpv3_firmware | * | |
netgear | wn3000rpv3 | - | |
netgear | lbr1020_firmware | * | |
netgear | lbr1020 | - | |
netgear | lbr20_firmware | * | |
netgear | lbr20 | - | |
netgear | r6700ax_firmware | * | |
netgear | r6700ax | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | rax10_firmware | * | |
netgear | rax10 | - | |
netgear | rax120v1_firmware | * | |
netgear | rax120v1 | - | |
netgear | rax120v2_firmware | * | |
netgear | rax120v2 | - | |
netgear | rax70_firmware | * | |
netgear | rax70 | - | |
netgear | rax78_firmware | * | |
netgear | rax78 | - | |
netgear | xr450_firmware | * | |
netgear | xr450 | - | |
netgear | xr500_firmware | * | |
netgear | xr500 | - | |
netgear | xr700_firmware | * | |
netgear | xr700 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EBB7728E-4535-4A67-9F8F-3CD4FE29C4A9", "versionEndExcluding": "1.0.1.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex2700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "110B4669-7AA6-4444-BFEF-9F7DF5C40D0B", "versionEndExcluding": "1.0.1.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex2700:-:*:*:*:*:*:*:*", "matchCriteriaId": "5341B659-DE7D-43F1-954D-82049CBE18AD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rpv2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A7305D0F-6995-411B-BDF6-106102C717AB", "versionEndExcluding": "1.0.0.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rpv2:-:*:*:*:*:*:*:*", "matchCriteriaId": "50BC8FA2-F9D5-4286-97DD-BD2A55EA234D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rpv3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "28C0758E-2793-4342-AEA0-DA7F49C4A38E", "versionEndExcluding": "1.0.2.100", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rpv3:-:*:*:*:*:*:*:*", "matchCriteriaId": "958243A2-6829-464F-80EA-7DD5B6F0DD7A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:lbr1020_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05E6F6DD-5CC6-426B-92F5-34B9A8525810", "versionEndExcluding": "2.6.5.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:lbr1020:-:*:*:*:*:*:*:*", "matchCriteriaId": "953F0743-4B34-4CE9-815E-D87253720CBE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:lbr20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8AAD88A5-E90E-4A96-BE01-DF14ADC44881", "versionEndExcluding": "2.6.5.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:lbr20:-:*:*:*:*:*:*:*", "matchCriteriaId": "863E45EA-2DA0-4C9A-9B87-79E42B3FF97C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700ax_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C65624DD-9DDF-4167-89D9-8629587082A6", "versionEndExcluding": "1.0.10.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700ax:-:*:*:*:*:*:*:*", "matchCriteriaId": "F9B37178-0C67-4EF0-A9B8-5BB5B9DBFB8F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76FAB8C7-79BA-4592-AF47-198D3EE48DCF", "versionEndExcluding": "1.0.2.86", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "13593203-FB80-4BDA-96CC-AAE5C33E560A", "versionEndExcluding": "1.0.5.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4D90EEE2-4D7C-46ED-9DF4-C232F30D97ED", "versionEndExcluding": "1.0.5.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax10_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FB930C5E-4232-4212-AFEB-A4D0904F2B22", "versionEndExcluding": "1.0.10.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax10:-:*:*:*:*:*:*:*", "matchCriteriaId": "1742F1BB-3D78-4E5E-9479-6614A56B4700", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax120v1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E370208B-8A35-4F76-8C79-BD5F1ABECA4D", "versionEndExcluding": "1.2.3.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax120v1:-:*:*:*:*:*:*:*", "matchCriteriaId": "774148F4-42EA-4F2A-98AB-1511DAB5774A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax120v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "91CED146-E9DC-4F73-A2CF-A6D78F29D0F7", "versionEndExcluding": "1.2.3.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax120v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "50D741E6-43F9-4BDC-B1A4-281AC73A7C19", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax70_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE615E08-904D-4DD5-835F-CE48B6D87650", "versionEndExcluding": "1.0.10.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax70:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE1314C3-4950-4F5A-9900-789710CE7F98", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax78_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A4940E3E-2320-4B73-B5DB-DDB7BE410EF0", "versionEndExcluding": "1.0.10.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax78:-:*:*:*:*:*:*:*", "matchCriteriaId": "EABDFEEF-228C-429E-9B80-B6A0CA7D5AA9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr450_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1EC1DFC6-B5A7-486B-BD50-BB79B3FF368A", "versionEndExcluding": "2.3.2.130", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr450:-:*:*:*:*:*:*:*", "matchCriteriaId": "66B9CE4D-D1EC-4F55-8226-D159CF5F3AB6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E50B1D80-6C4A-488D-8CAC-638DFFE23E6F", "versionEndExcluding": "2.3.2.130", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr500:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E203D92-F97B-4F5B-B395-3A5DEDBF1C1C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E3539C94-0B31-48FC-A432-3DC3E4E0CBBC", "versionEndExcluding": "1.0.1.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr700:-:*:*:*:*:*:*:*", "matchCriteriaId": "E12892C8-5E01-49A6-BF47-09D630377093", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.66, EX2700 before 1.0.1.68, WN3000RPv2 before 1.0.0.90, WN3000RPv3 before 1.0.2.100, LBR1020 before 2.6.5.20, LBR20 before 2.6.5.32, R6700AX before 1.0.10.110, R7800 before 1.0.2.86, R8900 before 1.0.5.38, R9000 before 1.0.5.38, RAX10 before 1.0.10.110, RAX120v1 before 1.2.3.28, RAX120v2 before 1.2.3.28, RAX70 before 1.0.10.110, RAX78 before 1.0.10.110, XR450 before 2.3.2.130, XR500 before 2.3.2.130, and XR700 before 1.0.1.46." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a D7800 versiones anteriores a 1.0.1.66, a EX2700 versiones anteriores a 1.0.1.68, al WN3000RPv2 versiones anteriores a 1.0.0.90, al WN3000RPv3 versiones anteriores a 1.0.2.100, a LBR1020 versiones anteriores a 2.6.5.20, a LBR20 versiones anteriores a 2.6.5.32, a R6700AX versiones anteriores a 1.0.10.110, a R7800 versiones anteriores a 1.0.2.86, a R8900 versiones anteriores a 1. 0.5.38, R9000 versiones anteriores a 1.0.5.38, RAX10 versiones anteriores a 1.0.10.110, RAX120v1 versiones anteriores a 1.2.3.28, RAX120v2 versiones anteriores a 1.2.3.28, RAX70 versiones anteriores a 1.0.10.110, RAX78 versiones anteriores a 1.0.10.110, XR450 versiones anteriores a 2.3.2.130, XR500 versiones anteriores a 2.3.2.130 y XR700 versiones anteriores a 1.0.1.46" } ], "id": "CVE-2021-45602", "lastModified": "2024-11-21T06:32:38.330", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 4.6, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "LOW", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:L", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 4.2, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:17.803", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://immersivelabs.com/resources/blog/netgear-vulnerabilities-could-put-small-business-routers-at-risk/" }, { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064407/Security-Advisory-for-Post-Authentication-Command-Injection-Sensitive-Information-Disclosure-on-Multiple-Products-PSV-2021-0169-PSV-2021-0171" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://immersivelabs.com/resources/blog/netgear-vulnerabilities-could-put-small-business-routers-at-risk/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064407/Security-Advisory-for-Post-Authentication-Command-Injection-Sensitive-Information-Disclosure-on-Multiple-Products-PSV-2021-0169-PSV-2021-0171" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
Vendor | Product | Version | |
---|---|---|---|
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | ex2700_firmware | * | |
netgear | ex2700 | - | |
netgear | wn3000rpv2_firmware | * | |
netgear | wn3000rpv2 | - | |
netgear | wn3000rpv3_firmware | * | |
netgear | wn3000rpv3 | - | |
netgear | lbr1020_firmware | * | |
netgear | lbr1020 | - | |
netgear | lbr20_firmware | * | |
netgear | lbr20 | - | |
netgear | r6700ax_firmware | * | |
netgear | r6700ax | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | rax10_firmware | * | |
netgear | rax10 | - | |
netgear | rax120v1_firmware | * | |
netgear | rax120v1 | - | |
netgear | rax120v2_firmware | * | |
netgear | rax120v2 | - | |
netgear | rax70_firmware | * | |
netgear | rax70 | - | |
netgear | rax78_firmware | * | |
netgear | rax78 | - | |
netgear | xr450_firmware | * | |
netgear | xr450 | - | |
netgear | xr500_firmware | * | |
netgear | xr500 | - | |
netgear | xr700_firmware | * | |
netgear | xr700 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EBB7728E-4535-4A67-9F8F-3CD4FE29C4A9", "versionEndExcluding": "1.0.1.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex2700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "110B4669-7AA6-4444-BFEF-9F7DF5C40D0B", "versionEndExcluding": "1.0.1.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex2700:-:*:*:*:*:*:*:*", "matchCriteriaId": "5341B659-DE7D-43F1-954D-82049CBE18AD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rpv2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A7305D0F-6995-411B-BDF6-106102C717AB", "versionEndExcluding": "1.0.0.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rpv2:-:*:*:*:*:*:*:*", "matchCriteriaId": "50BC8FA2-F9D5-4286-97DD-BD2A55EA234D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rpv3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "28C0758E-2793-4342-AEA0-DA7F49C4A38E", "versionEndExcluding": "1.0.2.100", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rpv3:-:*:*:*:*:*:*:*", "matchCriteriaId": "958243A2-6829-464F-80EA-7DD5B6F0DD7A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:lbr1020_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05E6F6DD-5CC6-426B-92F5-34B9A8525810", "versionEndExcluding": "2.6.5.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:lbr1020:-:*:*:*:*:*:*:*", "matchCriteriaId": "953F0743-4B34-4CE9-815E-D87253720CBE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:lbr20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8AAD88A5-E90E-4A96-BE01-DF14ADC44881", "versionEndExcluding": "2.6.5.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:lbr20:-:*:*:*:*:*:*:*", "matchCriteriaId": "863E45EA-2DA0-4C9A-9B87-79E42B3FF97C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700ax_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C65624DD-9DDF-4167-89D9-8629587082A6", "versionEndExcluding": "1.0.10.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700ax:-:*:*:*:*:*:*:*", "matchCriteriaId": "F9B37178-0C67-4EF0-A9B8-5BB5B9DBFB8F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76FAB8C7-79BA-4592-AF47-198D3EE48DCF", "versionEndExcluding": "1.0.2.86", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "13593203-FB80-4BDA-96CC-AAE5C33E560A", "versionEndExcluding": "1.0.5.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4D90EEE2-4D7C-46ED-9DF4-C232F30D97ED", "versionEndExcluding": "1.0.5.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax10_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FB930C5E-4232-4212-AFEB-A4D0904F2B22", "versionEndExcluding": "1.0.10.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax10:-:*:*:*:*:*:*:*", "matchCriteriaId": "1742F1BB-3D78-4E5E-9479-6614A56B4700", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax120v1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E370208B-8A35-4F76-8C79-BD5F1ABECA4D", "versionEndExcluding": "1.2.3.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax120v1:-:*:*:*:*:*:*:*", "matchCriteriaId": "774148F4-42EA-4F2A-98AB-1511DAB5774A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax120v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "91CED146-E9DC-4F73-A2CF-A6D78F29D0F7", "versionEndExcluding": "1.2.3.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax120v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "50D741E6-43F9-4BDC-B1A4-281AC73A7C19", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax70_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE615E08-904D-4DD5-835F-CE48B6D87650", "versionEndExcluding": "1.0.10.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax70:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE1314C3-4950-4F5A-9900-789710CE7F98", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax78_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A4940E3E-2320-4B73-B5DB-DDB7BE410EF0", "versionEndExcluding": "1.0.10.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax78:-:*:*:*:*:*:*:*", "matchCriteriaId": "EABDFEEF-228C-429E-9B80-B6A0CA7D5AA9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr450_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1EC1DFC6-B5A7-486B-BD50-BB79B3FF368A", "versionEndExcluding": "2.3.2.130", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr450:-:*:*:*:*:*:*:*", "matchCriteriaId": "66B9CE4D-D1EC-4F55-8226-D159CF5F3AB6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E50B1D80-6C4A-488D-8CAC-638DFFE23E6F", "versionEndExcluding": "2.3.2.130", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr500:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E203D92-F97B-4F5B-B395-3A5DEDBF1C1C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E3539C94-0B31-48FC-A432-3DC3E4E0CBBC", "versionEndExcluding": "1.0.1.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr700:-:*:*:*:*:*:*:*", "matchCriteriaId": "E12892C8-5E01-49A6-BF47-09D630377093", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of sensitive information. A UPnP request reveals a device\u0027s serial number, which can be used for a password reset. This affects D7800 before 1.0.1.66, EX2700 before 1.0.1.68, WN3000RPv2 before 1.0.0.90, WN3000RPv3 before 1.0.2.100, LBR1020 before 2.6.5.20, LBR20 before 2.6.5.32, R6700AX before 1.0.10.110, R7800 before 1.0.2.86, R8900 before 1.0.5.38, R9000 before 1.0.5.38, RAX10 before 1.0.10.110, RAX120v1 before 1.2.3.28, RAX120v2 before 1.2.3.28, RAX70 before 1.0.10.110, RAX78 before 1.0.10.110, XR450 before 2.3.2.130, XR500 before 2.3.2.130, and XR700 before 1.0.1.46." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una divulgaci\u00f3n de informaci\u00f3n confidencial. Una petici\u00f3n UPnP revela el n\u00famero de serie de un dispositivo, que puede ser usado para restablecer la contrase\u00f1a. Esto afecta a D7800 versiones anteriores a 1.0.1.66, a EX2700 versiones anteriores a 1.0.1.68, al WN3000RPv2 versiones anteriores a 1.0.0.90, al WN3000RPv3 versiones anteriores a 1.0.2.100, a LBR1020 versiones anteriores a 2.6.5.20, a LBR20 versiones anteriores a 2.6.5.32, a R6700AX versiones anteriores a 1.0.10.110, a R7800 versiones anteriores a 1.0.2.86, a R8900 versiones anteriores a 1. 0.5.38, R9000 versiones anteriores a 1.0.5.38, RAX10 versiones anteriores a 1.0.10.110, RAX120v1 versiones anteriores a 1.2.3.28, RAX120v2 versiones anteriores a 1.2.3.28, RAX70 versiones anteriores a 1.0.10.110, RAX78 versiones anteriores a 1.0.10.110, XR450 versiones anteriores a 2.3.2.130, XR500 versiones anteriores a 2.3.2.130 y XR700 versiones anteriores a 1.0.1.46" } ], "id": "CVE-2021-45603", "lastModified": "2024-11-21T06:32:38.527", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 2.1, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "LOW", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:L", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 4.2, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:17.853", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://immersivelabs.com/resources/blog/netgear-vulnerabilities-could-put-small-business-routers-at-risk/" }, { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064407/Security-Advisory-for-Post-Authentication-Command-Injection-Sensitive-Information-Disclosure-on-Multiple-Products-PSV-2021-0169-PSV-2021-0171" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://immersivelabs.com/resources/blog/netgear-vulnerabilities-could-put-small-business-routers-at-risk/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064407/Security-Advisory-for-Post-Authentication-Command-Injection-Sensitive-Information-Disclosure-on-Multiple-Products-PSV-2021-0169-PSV-2021-0171" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-200" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
Vendor | Product | Version | |
---|---|---|---|
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | rax120_firmware | * | |
netgear | rax120 | - | |
netgear | rbk22_firmware | * | |
netgear | rbk22 | - | |
netgear | rbr20_firmware | * | |
netgear | rbr20 | - | |
netgear | rbs20_firmware | * | |
netgear | rbs20 | - | |
netgear | rbk40_firmware | * | |
netgear | rbk40 | - | |
netgear | rbr40_firmware | * | |
netgear | rbr40 | - | |
netgear | rbs40_firmware | * | |
netgear | rbs40 | - | |
netgear | rbk50_firmware | * | |
netgear | rbk50 | - | |
netgear | rbr50_firmware | * | |
netgear | rbr50 | - | |
netgear | rbs50_firmware | * | |
netgear | rbs50 | - | |
netgear | wn3000rpv2_firmware | * | |
netgear | wn3000rpv2 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C35893A-C6C2-45C7-B3AF-BCFA62381BE5", "versionEndExcluding": "1.0.1.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "70E4DC5E-E34E-4AB1-BD50-F741142CB917", "versionEndExcluding": "1.0.2.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FF94E4E9-5F05-4727-BEEC-E6CAEF313864", "versionEndExcluding": "1.0.0.78", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax120:-:*:*:*:*:*:*:*", "matchCriteriaId": "1742BD56-84E4-40E1-8C04-098B3715161E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk22_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "42FB0A25-01DC-4864-B1FC-A315CA787B18", "versionEndExcluding": "2.3.5.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk22:-:*:*:*:*:*:*:*", "matchCriteriaId": "2E1BA765-5318-4A96-885D-3078148A74E4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA36B519-BB43-4329-96A5-842C74E05F8A", "versionEndExcluding": "2.3.5.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr20:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE5DBD66-9C2A-4EFF-87AB-03E791D584B5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B2FC86AC-1164-45C8-8D9E-6B88EC02B254", "versionEndExcluding": "2.3.5.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs20:-:*:*:*:*:*:*:*", "matchCriteriaId": "14FC7F5B-7E4F-4A68-8427-D1F553EBE8CA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "89C8AC8A-A1C8-4DA3-AFCC-F6A2E7367C7B", "versionEndExcluding": "2.3.5.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk40:-:*:*:*:*:*:*:*", "matchCriteriaId": "12DDD83C-6FF1-433F-ACA1-7B4B147F9A8C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A040117E-5DF5-4D8F-B0ED-E0ED148A6640", "versionEndExcluding": "2.3.5.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "A9E20E59-2B1E-4E43-A494-2C20FD716D4F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "624E85AD-3B34-413B-A271-1167CB551BD3", "versionEndExcluding": "2.3.5.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40:-:*:*:*:*:*:*:*", "matchCriteriaId": "6FDCDE39-0355-43B9-BF57-F3718DA2988D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B7ED1541-DE7D-4A4C-B8D1-CB42E52E3DBE", "versionEndExcluding": "2.3.5.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk50:-:*:*:*:*:*:*:*", "matchCriteriaId": "8BA66D07-D017-49D6-8E72-5C48E940DE1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "094B04D5-9063-4D7A-B367-E1F2688B3667", "versionEndExcluding": "2.3.5.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr50:-:*:*:*:*:*:*:*", "matchCriteriaId": "B2CAEA32-6934-4743-9E6B-22D52AC5E7F8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C489444C-6C19-4A52-AF66-A1D48ADC4F26", "versionEndExcluding": "2.3.5.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs50:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BCFD959-D522-4FA0-AD01-2937DAEE1EDF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rpv2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AA82BFA7-9B98-408C-BE81-E8D7532780A2", "versionEndExcluding": "1.0.0.78", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rpv2:-:*:*:*:*:*:*:*", "matchCriteriaId": "50BC8FA2-F9D5-4286-97DD-BD2A55EA234D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by stored XSS. This affects D7800 before 1.0.1.56, R7800 before 1.0.2.68, RAX120 before 1.0.0.78, RBK22 before 2.3.5.26, RBR20 before 2.3.5.26, RBS20 before 2.3.5.26, RBK40 before 2.3.5.30, RBR40 before 2.3.5.30, RBS40 before 2.3.5.30, RBK50 before 2.3.5.30, RBR50 before 2.3.5.30, RBS50 before 2.3.5.30, and WN3000RPv2 before 1.0.0.78." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una vulnerabilidad de tipo XSS almacenado.\u0026#xa0;Esto afecta a D7800 versiones anteriores a 1.0.1.56, R7800 versiones anteriores a 1.0.2.68, RAX120 versiones anteriores a 1.0.0.78, RBK22 versiones anteriores a 2.3.5.26, RBR20 versiones anteriores a 2.3.5.26, RBS20 versiones anteriores a 2.3.5.26, RBK40 versiones anteriores a 2.3.5.30, RBR40 versiones anteriores a 2.3.5.30, RBS40 versiones anteriores a 2.3.5.30, RBK50 versiones anteriores a 2.3.5.30, RBR50 versiones anteriores a 2.3.5.30, RBS50 versiones anteriores a 2.3.5.30 y WN3000RPv2 versiones anteriores a 1.0.0.78." } ], "id": "CVE-2020-35807", "lastModified": "2024-11-21T05:28:10.113", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 3.5, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 6.8, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 6.0, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 0.8, "impactScore": 5.2, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-12-30T00:15:14.800", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062730/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-and-Orbi-WiFi-Systems-PSV-2018-0557" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062730/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-and-Orbi-WiFi-Systems-PSV-2018-0557" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C8A5E09-861A-4C5F-8C0A-96803782E9EF", "versionEndExcluding": "1.0.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*", "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33C16A69-C930-4DA3-8750-EB50F2827731", "versionEndExcluding": "1.0.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9FCEBCD7-1D0D-47F6-BC72-A53BFBF3662D", "versionEndExcluding": "1.1.00.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6200:-:*:*:*:*:*:*:*", "matchCriteriaId": "00E6A1B7-4732-4259-9B71-10FF0B56A16B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4B185396-F010-45EF-B533-0AD61C095273", "versionEndExcluding": "1.0.0.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3EEA190-2E9C-4586-BF81-B115532FBA23", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "58E68C65-9685-40E8-8D51-6C922232168B", "versionEndExcluding": "1.0.0.86", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "7D30939B-86E3-4C78-9B05-686B4994C8B9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "53F5A909-D848-494E-9EB9-B794515372E2", "versionEndExcluding": "1.0.1.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "AF04B65B-9685-4595-9C71-0F77AD7109BE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "80764A3F-A007-44A8-A43C-55C918B5BBA5", "versionEndExcluding": "1.0.0.53", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "6DC6BD34-1A2C-4247-A20C-0B44C0F56E0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C35893A-C6C2-45C7-B3AF-BCFA62381BE5", "versionEndExcluding": "1.0.1.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C329B7CB-1281-480D-BDDB-E222044D715E", "versionEndExcluding": "1.0.3.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "814A0114-9A1D-4EA0-9AF4-6968514E4F01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dc112a_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDF9C0E1-7128-4052-B05E-3DD3394208A0", "versionEndExcluding": "1.0.0.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dc112a:-:*:*:*:*:*:*:*", "matchCriteriaId": "F87FFC46-137D-45B8-B437-F15565FB33D0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgn2200v4_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D4B3A29A-7C13-4B36-B14A-A7B6243F8034", "versionEndExcluding": "1.0.0.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgn2200v4:-:*:*:*:*:*:*:*", "matchCriteriaId": "0BE59214-C8A1-4337-A54C-E4E8C149B241", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgn2200bv4_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1406A926-8DBA-43B3-A0D7-BF4C9F991FDB", "versionEndExcluding": "1.0.0.109", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgn2200bv4:-:*:*:*:*:*:*:*", "matchCriteriaId": "9C78A475-9DDF-432B-A94A-01EFAC7DC70D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dm200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6B27650A-B7FE-41E4-8231-9283CC7B8349", "versionEndExcluding": "1.0.0.61", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dm200:-:*:*:*:*:*:*:*", "matchCriteriaId": "1B048F71-70F1-4D9F-84E2-9F7340F6ADAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0864CF6F-C025-44FE-B00F-83E14ACE1F8F", "versionEndExcluding": "1.0.0.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*", "matchCriteriaId": "CDAA5899-B73C-4690-853E-B5400F034BE1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B760484C-0D85-49BF-AA5D-2DB0A3A5D7E6", "versionEndExcluding": "1.0.0.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*", "matchCriteriaId": "CC5488D9-651C-4BAB-A141-06B816690D42", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D508F3C7-5A18-4983-8A30-755EA1F99DC5", "versionEndExcluding": "1.0.0.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*", "matchCriteriaId": "8C6DFDB6-1D7A-459A-8D30-FD4900ED718B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "18C88DDC-92C2-400E-8269-88A0EA65A98A", "versionEndExcluding": "1.0.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*", "matchCriteriaId": "305E295C-9C73-4798-A0BE-7973E1EE5EAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B2263B13-89CF-475E-ABE0-062783D924F7", "versionEndExcluding": "1.0.1.78", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F45B620-60B8-40F3-A055-181ADD71EFFF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:pr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "50E2E26A-200E-4D00-9657-034EACE3944F", "versionEndExcluding": "1.0.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:pr2000:-:*:*:*:*:*:*:*", "matchCriteriaId": "2451CC0C-71B2-474D-93F0-2B2ACD802FE3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "79B24229-6AC2-489D-B542-4DAA7E630180", "versionEndExcluding": "1.1.0.100", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "B131B5C8-CB7F-433B-BA32-F05CE0E92A66", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6230_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2B5B842D-2275-4968-997B-A70A67CBDBEC", "versionEndExcluding": "1.1.0.100", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6230:-:*:*:*:*:*:*:*", "matchCriteriaId": "C91CADFA-59DB-4B6C-A914-848884F4A4BD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6250_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E1DD1F7D-7556-4B95-A33F-E389948D20AA", "versionEndExcluding": "1.0.4.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6250:-:*:*:*:*:*:*:*", "matchCriteriaId": "321BE843-52C4-4638-A321-439CA7B3A6F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6300v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "34450066-658C-49CC-A853-2FA99ACAB205", "versionEndExcluding": "1.0.4.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6300v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "7909744D-FE9B-49D1-ADB3-029CCC432A47", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8BF91E85-8869-4421-8748-C7856C06435B", "versionEndExcluding": "1.0.1.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E4CDF6B-3829-44D0-9675-71D7BE83CAA2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D075FD21-C022-4246-8465-4EF79BADD29C", "versionEndExcluding": "1.0.2.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "AFE6B3A8-0601-44EA-AD9B-3BDDE6654FDF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AD6FD0FE-1431-4E39-8D07-B4AFE5BDB1B6", "versionEndExcluding": "1.0.2.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:-:*:*:*:*:*:*:*", "matchCriteriaId": "21B27F11-4262-4CE1-8107-B365A7C152F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700v3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D295754-5385-48CF-B354-3D3E5C53B1B2", "versionEndExcluding": "1.0.2.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700v3:-:*:*:*:*:*:*:*", "matchCriteriaId": "C88DA385-5FAE-49EC-80D6-78F81E7EEC16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5BB97877-F16D-4A9F-A130-9623A92C28DE", "versionEndExcluding": "1.0.2.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0794BB7C-1BCF-4F08-8EB2-9C3B150C105A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E453D3AE-A218-4791-BB19-79C2CF6EC6F8", "versionEndExcluding": "1.0.9.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0870C337-6BCE-4197-A9DE-6CED2B45AD58", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*", "matchCriteriaId": "366FA778-3C2A-42AF-9141-DAD7043B406C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B9F6D3F1-4064-4CAD-85D4-E1B2E72B440C", "versionEndExcluding": "1.0.3.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "2BCA6487-57EC-4630-884F-820BBFE25843", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8B02CB0A-BBB8-4A64-93B3-7CA1DF7B7299", "versionEndExcluding": "1.4.1.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9D3F1622-F2B7-41F0-87F0-61F4ACB270C8", "versionEndExcluding": "1.4.1.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E5AC056A-DF92-4CA7-9919-2C9BDAE3C32D", "versionEndExcluding": "1.0.4.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F1F914AD-70DC-47F5-A2F7-672DBE89C62E", "versionEndExcluding": "1.0.4.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "448D7EA1-A7BB-4AA5-8260-1D533D6A99AC", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk20:-:*:*:*:*:*:*:*", "matchCriteriaId": "E6C9F31C-3E12-4787-9C9B-14883D9D152A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1CC5263E-71E4-4B63-AD77-D1E72DC704B0", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk40:-:*:*:*:*:*:*:*", "matchCriteriaId": "12DDD83C-6FF1-433F-ACA1-7B4B147F9A8C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BA9F2B44-4114-495A-B200-B703FDFC3F8F", "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk50:-:*:*:*:*:*:*:*", "matchCriteriaId": "8BA66D07-D017-49D6-8E72-5C48E940DE1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1525B9D0-B147-437D-ACAE-58819A1F4FC6", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr20:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE5DBD66-9C2A-4EFF-87AB-03E791D584B5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D130E198-E9F5-4250-9C52-E39DF5C96711", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "A9E20E59-2B1E-4E43-A494-2C20FD716D4F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A25B8627-D325-493B-8B7D-4F900334F0D8", "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr50:-:*:*:*:*:*:*:*", "matchCriteriaId": "B2CAEA32-6934-4743-9E6B-22D52AC5E7F8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4515F985-B714-480C-8FBA-2499A29F29FA", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs20:-:*:*:*:*:*:*:*", "matchCriteriaId": "14FC7F5B-7E4F-4A68-8427-D1F553EBE8CA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "08426AC6-4811-43E8-87EB-204A2729C49B", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40:-:*:*:*:*:*:*:*", "matchCriteriaId": "6FDCDE39-0355-43B9-BF57-F3718DA2988D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81ED6C61-2A7C-49EC-BD3D-466442EF715C", "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs50:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BCFD959-D522-4FA0-AD01-2937DAEE1EDF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rpv2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AA82BFA7-9B98-408C-BE81-E8D7532780A2", "versionEndExcluding": "1.0.0.78", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rpv2:-:*:*:*:*:*:*:*", "matchCriteriaId": "50BC8FA2-F9D5-4286-97DD-BD2A55EA234D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000v5_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8D1EF946-5FEF-4DD7-8567-CB435FAA41E2", "versionEndExcluding": "1.0.0.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000v5_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "F024A464-DB7D-4F6E-A951-3D8068F86470", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3400v3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C3B2795-B3B0-4709-B37B-46A713BCCABE", "versionEndExcluding": "1.0.1.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3400v3:-:*:*:*:*:*:*:*", "matchCriteriaId": "37F227D8-332F-4D24-BAEA-AA5DB3E3EC95", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2020_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E0141851-BE96-4F6A-883F-3B20AE6945C1", "versionEndExcluding": "1.1.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2020:-:*:*:*:*:*:*:*", "matchCriteriaId": "C2189628-03E7-445A-9EF2-656A85539115", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AA9B22EF-5791-41DB-8CC1-A1B60CF4A73F", "versionEndExcluding": "2.3.2.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr500:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E203D92-F97B-4F5B-B395-3A5DEDBF1C1C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D3600 before 1.0.0.72, D6000 before 1.0.0.72, D6200 before 1.1.00.34, D6220 before 1.0.0.52, D6400 before 1.0.0.86, D7000 before 1.0.1.74, D7000v2 before 1.0.0.53, D7800 before 1.0.1.56, D8500 before 1.0.3.44, DC112A before 1.0.0.42, DGN2200Bv4 before 1.0.0.109, DGN2200v4 before 1.0.0.110, DM200 before 1.0.0.61, EX3700 before 1.0.0.76, EX3800 before 1.0.0.76, EX6120 before 1.0.0.46, EX6130 before 1.0.0.28, EX7000 before 1.0.1.78, PR2000 before 1.0.0.28, R6220 before 1.1.0.100, R6230 before 1.1.0.100, R6250 before 1.0.4.34, R6300v2 before 1.0.4.34, R6400 before 1.0.1.46, R6400v2 before 1.0.2.66, R6700v3 before 1.0.2.66, R6700 before 1.0.2.6, R6900 before 1.0.2.6, R7000 before 1.0.9.34, R7100LG before 1.0.0.50, R7500v2 before 1.0.3.40, R7900P before 1.4.1.50, R8000P before 1.4.1.50, R8900 before 1.0.4.12, R9000 before 1.0.4.12, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK40 before 2.3.0.28, RBR40 before 2.3.0.28, RBS40 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, WN3000RPv2 before 1.0.0.78, WNDR3400v3 before 1.0.1.24, WNR2000v5 before 1.0.0.70, WNR2020 before 1.1.0.62, and XR500 before 2.3.2.56." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una configuraci\u00f3n incorrecta de los ajustes de seguridad. Esto afecta a D3600 versiones anteriores a 1.0.0.72, D6000 versiones anteriores a 1.0.0.72, D6200 versiones anteriores a 1.1.00.34, D6220 versiones anteriores a 1.0.0.52, D6400 versiones anteriores a 1.0.0.86, D7000 versiones anteriores a 1.0. 1.74, D7000v2 versiones anteriores a 1.0.0.53, D7800 versiones anteriores a 1.0.1.56, D8500 versiones anteriores a 1.0.3.44, DC112A versiones anteriores a 1.0.0.42, DGN2200Bv4 versiones anteriores a 1.0.0.109, DGN2200v4 versiones anteriores a 1. 0.0.110, DM200 versiones anteriores a 1.0.0.61, EX3700 versiones anteriores a 1.0.0.76, EX3800 versiones anteriores a 1.0.0.76, EX6120 versiones anteriores a 1.0.0.46, EX6130 versiones anteriores a 1.0.0.28, EX7000 versiones anteriores a 1. 0.1.78, PR2000 versiones anteriores a 1.0.0.28, R6220 versiones anteriores a 1.1.0.100, R6230 versiones anteriores a 1.1.0.100, R6250 versiones anteriores a 1.0.4.34, R6300v2 versiones anteriores a 1.0.4.34, R6400 versiones anteriores a 1.0.1. 46, R6400v2 versiones anteriores a 1.0.2.66, R6700v3 versiones anteriores a 1.0.2.66, R6700 versiones anteriores a 1.0.2.6, R6900 versiones anteriores a 1.0.2.6, R7000 versiones anteriores a 1.0.9.34, R7100LG versiones anteriores a 1.0.0. 50, R7500v2 versiones anteriores a 1.0.3.40, R7900P versiones anteriores a 1.4.1.50, R8000P versiones anteriores a 1.4.1.50, R8900 versiones anteriores a 1.0.4.12, R9000 versiones anteriores a 1.0.4.12, RBK20 versiones anteriores a 2.3.0.28, RBR20 versiones anteriores a 2. 3.0.28, RBS20 versiones anteriores a 2.3.0.28, RBK40 versiones anteriores a 2.3.0.28, RBR40 versiones anteriores a 2.3.0.28, RBS40 versiones anteriores a 2.3.0.28, RBK50 versiones anteriores a 2.3.0.32, RBR50 versiones anteriores a 2.3.0. 32, RBS50 versiones anteriores a 2.3.0.32, WN3000RPv2 versiones anteriores a 1.0.0.78, WNDR3400v3 versiones anteriores a 1.0.1.24, WNR2000v5 versiones anteriores a 1.0.0.70, WNR2020 versiones anteriores a 1.1.0.62 y XR500 versiones anteriores a 2.3.2.56" } ], "id": "CVE-2021-45641", "lastModified": "2024-11-21T06:32:45.310", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 4.6, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.1, "impactScore": 2.5, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:19.690", "references": [ { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064053/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2018-0624" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064053/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2018-0624" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
Vendor | Product | Version | |
---|---|---|---|
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r7500v2_firmware | * | |
netgear | r7500v2 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | rax120_firmware | * | |
netgear | rax120 | - | |
netgear | rbk22_firmware | * | |
netgear | rbk22 | - | |
netgear | rbr20_firmware | * | |
netgear | rbr20 | - | |
netgear | rbs20_firmware | * | |
netgear | rbs20 | - | |
netgear | rbk40_firmware | * | |
netgear | rbk40 | - | |
netgear | rbr40_firmware | * | |
netgear | rbr40 | - | |
netgear | rbs40_firmware | * | |
netgear | rbs40 | - | |
netgear | rbk50_firmware | * | |
netgear | rbk50 | - | |
netgear | rbr50_firmware | * | |
netgear | rbr50 | - | |
netgear | rbs50_firmware | * | |
netgear | rbs50 | - | |
netgear | wn3000rpv2_firmware | * | |
netgear | wn3000rpv2 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C35893A-C6C2-45C7-B3AF-BCFA62381BE5", "versionEndExcluding": "1.0.1.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "801B6E47-327F-4C7F-B3BD-CC08F94B19AC", "versionEndExcluding": "1.0.3.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "2BCA6487-57EC-4630-884F-820BBFE25843", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "70E4DC5E-E34E-4AB1-BD50-F741142CB917", "versionEndExcluding": "1.0.2.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FF94E4E9-5F05-4727-BEEC-E6CAEF313864", "versionEndExcluding": "1.0.0.78", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax120:-:*:*:*:*:*:*:*", "matchCriteriaId": "1742BD56-84E4-40E1-8C04-098B3715161E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk22_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "42FB0A25-01DC-4864-B1FC-A315CA787B18", "versionEndExcluding": "2.3.5.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk22:-:*:*:*:*:*:*:*", "matchCriteriaId": "2E1BA765-5318-4A96-885D-3078148A74E4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA36B519-BB43-4329-96A5-842C74E05F8A", "versionEndExcluding": "2.3.5.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr20:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE5DBD66-9C2A-4EFF-87AB-03E791D584B5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B2FC86AC-1164-45C8-8D9E-6B88EC02B254", "versionEndExcluding": "2.3.5.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs20:-:*:*:*:*:*:*:*", "matchCriteriaId": "14FC7F5B-7E4F-4A68-8427-D1F553EBE8CA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "89C8AC8A-A1C8-4DA3-AFCC-F6A2E7367C7B", "versionEndExcluding": "2.3.5.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk40:-:*:*:*:*:*:*:*", "matchCriteriaId": "12DDD83C-6FF1-433F-ACA1-7B4B147F9A8C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A040117E-5DF5-4D8F-B0ED-E0ED148A6640", "versionEndExcluding": "2.3.5.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "A9E20E59-2B1E-4E43-A494-2C20FD716D4F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "624E85AD-3B34-413B-A271-1167CB551BD3", "versionEndExcluding": "2.3.5.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40:-:*:*:*:*:*:*:*", "matchCriteriaId": "6FDCDE39-0355-43B9-BF57-F3718DA2988D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B7ED1541-DE7D-4A4C-B8D1-CB42E52E3DBE", "versionEndExcluding": "2.3.5.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk50:-:*:*:*:*:*:*:*", "matchCriteriaId": "8BA66D07-D017-49D6-8E72-5C48E940DE1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "094B04D5-9063-4D7A-B367-E1F2688B3667", "versionEndExcluding": "2.3.5.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr50:-:*:*:*:*:*:*:*", "matchCriteriaId": "B2CAEA32-6934-4743-9E6B-22D52AC5E7F8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C489444C-6C19-4A52-AF66-A1D48ADC4F26", "versionEndExcluding": "2.3.5.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs50:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BCFD959-D522-4FA0-AD01-2937DAEE1EDF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rpv2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AA82BFA7-9B98-408C-BE81-E8D7532780A2", "versionEndExcluding": "1.0.0.78", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rpv2:-:*:*:*:*:*:*:*", "matchCriteriaId": "50BC8FA2-F9D5-4286-97DD-BD2A55EA234D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by stored XSS. This affects D7800 before 1.0.1.56, R7500v2 before 1.0.3.46, R7800 before 1.0.2.68, RAX120 before 1.0.0.78, RBK22 before 2.3.5.26, RBR20 before 2.3.5.26, RBS20 before 2.3.5.26, RBK40 before 2.3.5.30, RBR40 before 2.3.5.30, RBS40 before 2.3.5.30, RBK50 before 2.3.5.30, RBR50 before 2.3.5.30, RBS50 before 2.3.5.30, and WN3000RPv2 before 1.0.0.78." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una vulnerabilidad de tipo XSS almacenado.\u0026#xa0;Esto afecta a D7800 versiones anteriores a 1.0.1.56, R7500v2 versiones anteriores a 1.0.3.46, R7800 versiones anteriores a 1.0.2.68, RAX120 versiones anteriores a 1.0.0.78, RBK22 versiones anteriores a 2.3.5.26, RBR20 versiones anteriores a 2.3.5.26, RBS20 versiones anteriores a 2.3.5.26, RBK40 versiones anteriores a 2.3.5.30, RBR40 versiones anteriores a 2.3.5.30, RBS40 versiones anteriores a 2.3.5.30, RBK50 versiones anteriores a 2.3.5.30, RBR50 versiones anteriores a 2.3.5.30, RBS50 versiones anteriores a 2.3.5.30 y WN3000RPv2 versiones anteriores a 1.0.0.78." } ], "id": "CVE-2020-35806", "lastModified": "2024-11-21T05:28:09.920", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 3.5, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 6.8, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 6.0, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 0.8, "impactScore": 5.2, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-12-30T00:15:14.737", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062729/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-and-Orbi-WiFi-Systems-PSV-2018-0539" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062729/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-and-Orbi-WiFi-Systems-PSV-2018-0539" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7BECFDEE-A795-43F1-9651-13096141B3BE", "versionEndExcluding": "1.0.0.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*", "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "358AD63C-C3D0-4749-BA4D-AA22815EA5E1", "versionEndExcluding": "1.0.078", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A779DDFF-420F-4853-A7D8-F8E5A2A98D12", "versionEndExcluding": "1.1.00.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6200:-:*:*:*:*:*:*:*", "matchCriteriaId": "00E6A1B7-4732-4259-9B71-10FF0B56A16B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D127F467-E2D0-462C-B9E1-458CFFFAC062", "versionEndExcluding": "1.0.1.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "AF04B65B-9685-4595-9C71-0F77AD7109BE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C35893A-C6C2-45C7-B3AF-BCFA62381BE5", "versionEndExcluding": "1.0.1.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dm200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6B27650A-B7FE-41E4-8231-9283CC7B8349", "versionEndExcluding": "1.0.0.61", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dm200:-:*:*:*:*:*:*:*", "matchCriteriaId": "1B048F71-70F1-4D9F-84E2-9F7340F6ADAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex2700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CD898239-AEDF-4CA5-A5AE-946584971C8F", "versionEndExcluding": "1.0.1.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex2700:-:*:*:*:*:*:*:*", "matchCriteriaId": "5341B659-DE7D-43F1-954D-82049CBE18AD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6100v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2FB7AC1F-9DCC-47F5-8CDC-FA4786EEF9EA", "versionEndExcluding": "1.0.1.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6100v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "4DCFF79A-8ACE-455B-90F3-FFC745E8BAD4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6150v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "13A66A85-1F7D-4A1D-B2B6-D0E1318CC2A1", "versionEndExcluding": "1.0.1.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6150v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "5828F04B-E373-4E4F-942D-08CCA038418C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6200v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "464F3374-0B87-4920-A383-737C4F8F66BF", "versionEndExcluding": "1.0.1.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6200v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "2141AE0A-18CB-4142-A850-B2153DAEE5A8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F42BDEFE-DBA2-4705-B7F6-86B5D5858F4C", "versionEndExcluding": "1.0.2.140", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "1289BBB4-1955-46A4-B5FE-BF11153C24F5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "308411F8-8FDD-4544-A4D8-FEC2F16597DC", "versionEndExcluding": "1.0.2.140", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7300:-:*:*:*:*:*:*:*", "matchCriteriaId": "F285D60D-A5DA-4467-8F79-15EF8135D007", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EBCC111C-7F79-4F20-B007-279EAA197D4D", "versionEndExcluding": "1.0.1.186", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "8D9781C9-799A-4BDA-A027-987627A01633", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jr6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC9C60BB-2E7F-4D35-9348-8D8AEFAAD75F", "versionEndExcluding": "1.0.1.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jr6150:-:*:*:*:*:*:*:*", "matchCriteriaId": "D67167E5-81D2-4892-AF41-CBB6271232D1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:pr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "50E2E26A-200E-4D00-9657-034EACE3944F", "versionEndExcluding": "1.0.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:pr2000:-:*:*:*:*:*:*:*", "matchCriteriaId": "2451CC0C-71B2-474D-93F0-2B2ACD802FE3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6020_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27FC1738-5A2C-4D4B-944C-1EB1A8D2476E", "versionEndExcluding": "1.0.0.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6020:-:*:*:*:*:*:*:*", "matchCriteriaId": "5DDA7ABF-4C4B-4945-993A-F93BD8FCB55E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6050_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EDB0CD0A-A68D-4EF5-A938-6A15604C9107", "versionEndExcluding": "1.0.1.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6050:-:*:*:*:*:*:*:*", "matchCriteriaId": "363D4DEE-98B9-4294-B241-1613CAD1A3A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6080_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "442B71BC-D2D4-4F0F-8962-B50D5E8D2833", "versionEndExcluding": "1.0.0.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6080:-:*:*:*:*:*:*:*", "matchCriteriaId": "1CEB5C49-53CF-44AE-9A7D-E7E6201BFE62", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "92F53D21-C688-4477-815D-EFFF08F7D085", "versionEndExcluding": "1.0.0.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6120:-:*:*:*:*:*:*:*", "matchCriteriaId": "D18D2CCD-424F-41D5-919B-E22B9FA68D36", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "220EBC67-69DA-43D6-8B09-EBEEEF29679D", "versionEndExcluding": "1.1.0.80", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "B131B5C8-CB7F-433B-BA32-F05CE0E92A66", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6230_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9466A450-0351-4B2D-B816-6A1B6F4F34B9", "versionEndExcluding": "1.1.0.80", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6230:-:*:*:*:*:*:*:*", "matchCriteriaId": "C91CADFA-59DB-4B6C-A914-848884F4A4BD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6260_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FF20BDF1-ADE3-4C82-8E11-C720DA0BCD26", "versionEndExcluding": "1.1.0.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6260:-:*:*:*:*:*:*:*", "matchCriteriaId": "3C395D49-57F9-4BC1-8619-57127355B86B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F9079C37-0E23-40F5-BDD8-F4757773D670", "versionEndExcluding": "1.2.0.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9793286-86D2-43BF-B9B8-823C05BCAE4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3C39CE79-6433-47E2-A439-9AB1DFBD843C", "versionEndExcluding": "1.2.0.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6800:-:*:*:*:*:*:*:*", "matchCriteriaId": "09404083-B00B-4C1F-8085-BC242E625CA3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2B21EF2E-C6A8-4EA2-9247-0DD2FD8C84F0", "versionEndExcluding": "1.2.0.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "A9FC6398-60A5-4003-A294-C96AE6DBCED5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B9F6D3F1-4064-4CAD-85D4-E1B2E72B440C", "versionEndExcluding": "1.0.3.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "2BCA6487-57EC-4630-884F-820BBFE25843", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6915C426-7EEB-43AA-A56A-A1DABF6DF9E7", "versionEndExcluding": "1.0.2.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E5AC056A-DF92-4CA7-9919-2C9BDAE3C32D", "versionEndExcluding": "1.0.4.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F1F914AD-70DC-47F5-A2F7-672DBE89C62E", "versionEndExcluding": "1.0.4.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "448D7EA1-A7BB-4AA5-8260-1D533D6A99AC", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk20:-:*:*:*:*:*:*:*", "matchCriteriaId": "E6C9F31C-3E12-4787-9C9B-14883D9D152A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1525B9D0-B147-437D-ACAE-58819A1F4FC6", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr20:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE5DBD66-9C2A-4EFF-87AB-03E791D584B5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4515F985-B714-480C-8FBA-2499A29F29FA", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs20:-:*:*:*:*:*:*:*", "matchCriteriaId": "14FC7F5B-7E4F-4A68-8427-D1F553EBE8CA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1CC5263E-71E4-4B63-AD77-D1E72DC704B0", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk40:-:*:*:*:*:*:*:*", "matchCriteriaId": "12DDD83C-6FF1-433F-ACA1-7B4B147F9A8C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D130E198-E9F5-4250-9C52-E39DF5C96711", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "A9E20E59-2B1E-4E43-A494-2C20FD716D4F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "08426AC6-4811-43E8-87EB-204A2729C49B", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40:-:*:*:*:*:*:*:*", "matchCriteriaId": "6FDCDE39-0355-43B9-BF57-F3718DA2988D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BA9F2B44-4114-495A-B200-B703FDFC3F8F", "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk50:-:*:*:*:*:*:*:*", "matchCriteriaId": "8BA66D07-D017-49D6-8E72-5C48E940DE1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A25B8627-D325-493B-8B7D-4F900334F0D8", "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr50:-:*:*:*:*:*:*:*", "matchCriteriaId": "B2CAEA32-6934-4743-9E6B-22D52AC5E7F8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81ED6C61-2A7C-49EC-BD3D-466442EF715C", "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs50:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BCFD959-D522-4FA0-AD01-2937DAEE1EDF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn2000rptv3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9E06335E-EF1B-46F7-9F6A-4B749BA4D609", "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn2000rptv3:-:*:*:*:*:*:*:*", "matchCriteriaId": "BF128F22-9103-4878-A270-7FC5C97E4F13", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rpv2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AA82BFA7-9B98-408C-BE81-E8D7532780A2", "versionEndExcluding": "1.0.0.78", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rpv2:-:*:*:*:*:*:*:*", "matchCriteriaId": "50BC8FA2-F9D5-4286-97DD-BD2A55EA234D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rpv2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AA82BFA7-9B98-408C-BE81-E8D7532780A2", "versionEndExcluding": "1.0.0.78", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rpv2:-:*:*:*:*:*:*:*", "matchCriteriaId": "50BC8FA2-F9D5-4286-97DD-BD2A55EA234D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rpv3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E1947AF4-32F6-41E7-9040-E1FF5FFB3164", "versionEndExcluding": "1.0.2.78", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rpv3:-:*:*:*:*:*:*:*", "matchCriteriaId": "958243A2-6829-464F-80EA-7DD5B6F0DD7A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3100rpv2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "09A22719-8CA4-452A-80E7-3A8CC50E7DD8", "versionEndExcluding": "1.0.0.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3100rpv2:-:*:*:*:*:*:*:*", "matchCriteriaId": "8E243DEF-0496-4752-B5B6-69F13E3D2C95", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000v5_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8D1EF946-5FEF-4DD7-8567-CB435FAA41E2", "versionEndExcluding": "1.0.0.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000v5:-:*:*:*:*:*:*:*", "matchCriteriaId": "671EC923-DC84-47D6-B943-0F7DA8168334", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2020_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E0141851-BE96-4F6A-883F-3B20AE6945C1", "versionEndExcluding": "1.1.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2020:-:*:*:*:*:*:*:*", "matchCriteriaId": "C2189628-03E7-445A-9EF2-656A85539115", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr450_firmware:2.3.2.32:*:*:*:*:*:*:*", "matchCriteriaId": "DC0F3168-675B-4B0B-A48B-3748A8F7E4E4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr450:-:*:*:*:*:*:*:*", "matchCriteriaId": "66B9CE4D-D1EC-4F55-8226-D159CF5F3AB6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr500_firmware:2.3.2.32:*:*:*:*:*:*:*", "matchCriteriaId": "D6FF327C-98A6-4A6A-A439-1D9C08FCD27D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr500:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E203D92-F97B-4F5B-B395-3A5DEDBF1C1C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.76, D6000 before 1.0.0.78, D6200 before 1.1.00.32, D7000 before 1.0.1.68, D7800 before 1.0.1.56, DM200 before 1.0.0.61, EX2700 before 1.0.1.52, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.74, EX6400 before 1.0.2.140, EX7300 before 1.0.2.140, EX8000 before 1.0.1.186, JR6150 before 1.0.1.18, PR2000 before 1.0.0.28, R6020 before 1.0.0.38, R6050 before 1.0.1.18, R6080 before 1.0.0.38, R6120 before 1.0.0.46, R6220 before 1.1.0.80, R6230 before 1.1.0.80, R6260 before 1.1.0.40, R6700v2 before 1.2.0.36, R6800 before 1.2.0.36, R6900v2 before 1.2.0.36, R7500v2 before 1.0.3.40, R7800 before 1.0.2.62, R8900 before 1.0.4.12, R9000 before 1.0.4.12, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK40 before 2.3.0.28, RBR40 before 2.3.0.28, RBS40 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, WN2000RPTv3 before 1.0.1.34, WN3000RPv2 before 1.0.0.78, WN3000RPv2 before 1.0.0.78, WN3000RPv3 before 1.0.2.78, WN3100RPv2 before 1.0.0.66, WNR2000v5 before 1.0.0.70, WNR2020 before 1.1.0.62, XR450 before 2.3.2.32, and XR500 before 2.3.2.32." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un atacante no autenticado.\u0026#xa0;Esto afecta a D3600 versiones anteriores a 1.0.0.76, D6000 versiones anteriores a 1.0.0.78, D6200 versiones anteriores a 1.1.00.32, D7000 versiones anteriores a 1.0.1.68, D7800 versiones anteriores a 1.0.1.56, DM200 versiones anteriores a 1.0.0.61, EX2700 versiones anteriores a 1.0.1.52, EX6100v2 versiones anteriores a 1.0.1.76, EX6150v2 versiones anteriores a 1.0.1.76, EX6200v2 versiones anteriores a 1.0.1.74, EX6400 versiones anteriores a 1.0.2.140, EX7300 versiones anteriores a 1.0.2.140, EX8000 versiones anteriores a 1.0.1.186, JR6150 versiones anteriores a 1.0.1.18, PR2000 versiones anteriores a 1.0.0.28, R6020 versiones anteriores a 1.0.0.38, R6050 versiones anteriores a 1.0.1.18, R6080 versiones anteriores a 1.0.0.38, R6120 versiones anteriores a 1.0.0.46, R6220 versiones anteriores a 1.1.0.80, R6230 versiones anteriores a 1.1.0.80, R6260 versiones anteriores a 1.1.0.40, R6700v2 versiones anteriores a 1.2.0.36, R6800 versiones anteriores a 1.2.0.36, R6900v2 versiones anteriores a 1.2. 0.36, R7500v2 versiones anteriores a 1.0.3.40, R7800 versiones anteriores a 1.0.2.62, R8900 versiones anteriores a 1.0.4.12, R9000 versiones anteriores a 1.0.4.12, RBK20 versiones anteriores a 2.3.0.28, RBR20 versiones anteriores a 2.3.0.28, RBS20 versiones anteriores a 2.3.0.28, RBK40 versiones anteriores a 2.3.0.28, RBR40 versiones anteriores a 2.3.0.28, RBS40 versiones anteriores a 2.3.0.28, RBK50 versiones anteriores a 2.3.0.32, RBR50 versiones anteriores a 2.3.0.32, RBS50 versiones anteriores a 2.3.0.32, WN2000RPTv3 versiones anteriores a 1.0.1.34, WN3000RPv2 versiones anteriores a 1.0.0.78, WN3000RPv2 versiones anteriores a 1.0.0.78, WN3000RPv3 versiones anteriores a 1.0.2.78, WN3100RPv2 versiones anteriores a 1.0.0.66, WNR2000v5 versiones anteriores a 1.0.0.70, WNR2020 versiones anteriores a 1.1.0.62, XR450 versiones anteriores a 2.3.2.32, y XR500 versiones anteriores a 2.3.2.32." } ], "id": "CVE-2020-35799", "lastModified": "2024-11-21T05:28:08.360", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-12-30T00:15:14.347", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062709/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-Range-Extenders-and-WiFi-Systems-PSV-2018-0296" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062709/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-Range-Extenders-and-WiFi-Systems-PSV-2018-0296" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | rbk20_firmware | * | |
netgear | rbk20 | - | |
netgear | rbr20_firmware | * | |
netgear | rbr20 | - | |
netgear | rbs20_firmware | * | |
netgear | rbs20 | - | |
netgear | rbk50_firmware | * | |
netgear | rbk50 | - | |
netgear | rbr50_firmware | * | |
netgear | rbr50 | - | |
netgear | rbs50_firmware | * | |
netgear | rbs50 | - | |
netgear | rbk40_firmware | * | |
netgear | rbk40 | - | |
netgear | rbs40_firmware | * | |
netgear | rbs40 | - | |
netgear | srk60_firmware | * | |
netgear | srk60 | - | |
netgear | srr60_firmware | * | |
netgear | srr60 | - | |
netgear | srs60_firmware | * | |
netgear | srs60 | - | |
netgear | wn3000rpv2_firmware | * | |
netgear | wn3000rpv2 | - | |
netgear | wndr4300v2_firmware | * | |
netgear | wndr4300v2 | - | |
netgear | wndr4500v3_firmware | * | |
netgear | wndr4500v3 | - | |
netgear | wnr2000v5_firmware | * | |
netgear | wnr2000v5 | - | |
netgear | xr450_firmware | * | |
netgear | xr450 | - | |
netgear | xr500_firmware | * | |
netgear | xr500 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8DE5478F-11CE-4730-AC60-64ACE7BBB03A", "versionEndExcluding": "1.0.0.63", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "52E997BC-B5C7-4FBA-9535-6A0BA398F8C3", "versionEndExcluding": "1.0.2.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BEF7967B-5FA3-4D43-BEC5-2644FBB1D168", "versionEndExcluding": "1.0.4.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D34DD834-FE59-4F04-9448-FDC385CF70F6", "versionEndExcluding": "1.0.4.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "448D7EA1-A7BB-4AA5-8260-1D533D6A99AC", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk20:-:*:*:*:*:*:*:*", "matchCriteriaId": "E6C9F31C-3E12-4787-9C9B-14883D9D152A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1525B9D0-B147-437D-ACAE-58819A1F4FC6", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr20:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE5DBD66-9C2A-4EFF-87AB-03E791D584B5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4515F985-B714-480C-8FBA-2499A29F29FA", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs20:-:*:*:*:*:*:*:*", "matchCriteriaId": "14FC7F5B-7E4F-4A68-8427-D1F553EBE8CA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BA9F2B44-4114-495A-B200-B703FDFC3F8F", "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk50:-:*:*:*:*:*:*:*", "matchCriteriaId": "8BA66D07-D017-49D6-8E72-5C48E940DE1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A25B8627-D325-493B-8B7D-4F900334F0D8", "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr50:-:*:*:*:*:*:*:*", "matchCriteriaId": "B2CAEA32-6934-4743-9E6B-22D52AC5E7F8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81ED6C61-2A7C-49EC-BD3D-466442EF715C", "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs50:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BCFD959-D522-4FA0-AD01-2937DAEE1EDF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1CC5263E-71E4-4B63-AD77-D1E72DC704B0", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk40:-:*:*:*:*:*:*:*", "matchCriteriaId": "12DDD83C-6FF1-433F-ACA1-7B4B147F9A8C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "08426AC6-4811-43E8-87EB-204A2729C49B", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40:-:*:*:*:*:*:*:*", "matchCriteriaId": "6FDCDE39-0355-43B9-BF57-F3718DA2988D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:srk60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F844694F-AAC1-466E-AB59-E27FFA315C18", "versionEndExcluding": "2.2.2.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:srk60:-:*:*:*:*:*:*:*", "matchCriteriaId": "DCC347EB-699E-4626-A944-2D378101DDCF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:srr60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4E5130E8-336A-4352-9E71-2FD2519A2F15", "versionEndExcluding": "2.2.2.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:srr60:-:*:*:*:*:*:*:*", "matchCriteriaId": "55E6F589-04DA-431C-9E03-BA2A59BB0E4A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:srs60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D81891A8-FD3C-4F35-BA0E-3F9522292B66", "versionEndExcluding": "2.2.2.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:srs60:-:*:*:*:*:*:*:*", "matchCriteriaId": "BFB01247-A20F-41CA-8718-E8E60E7F14B3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rpv2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AA82BFA7-9B98-408C-BE81-E8D7532780A2", "versionEndExcluding": "1.0.0.78", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rpv2:-:*:*:*:*:*:*:*", "matchCriteriaId": "50BC8FA2-F9D5-4286-97DD-BD2A55EA234D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DE79DB12-F18E-49DE-A1F2-BF3BDD5E44E4", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "512AD9E6-F154-483D-AA18-3302CEBB5B79", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500v3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B8DCB117-4B58-4CBC-9E25-F98BB6C2B2BC", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500v3:-:*:*:*:*:*:*:*", "matchCriteriaId": "EDA7C60F-8806-476C-A833-44E2BE66265B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000v5_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8D1EF946-5FEF-4DD7-8567-CB435FAA41E2", "versionEndExcluding": "1.0.0.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000v5:-:*:*:*:*:*:*:*", "matchCriteriaId": "671EC923-DC84-47D6-B943-0F7DA8168334", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr450_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DF16407-DB09-4174-A435-F7AF209E4260", "versionEndExcluding": "2.3.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr450:-:*:*:*:*:*:*:*", "matchCriteriaId": "66B9CE4D-D1EC-4F55-8226-D159CF5F3AB6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8752321F-E9BF-427B-88FD-B67014FB2FD5", "versionEndExcluding": "2.3.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr500:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E203D92-F97B-4F5B-B395-3A5DEDBF1C1C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.63, R7800 before 1.0.2.60, R8900 before 1.0.4.26, R9000 before 1.0.4.26, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, RBK40 before 2.3.0.28, RBR40 before 2.3.0.28, RBS40 before 2.3.0.28, SRK60 before 2.2.2.20, SRR60 before 2.2.2.20, SRS60 before 2.2.2.20, WN3000RPv2 before 1.0.0.78, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.70, XR450 before 2.3.2.40, and XR500 before 2.3.2.40." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR, est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado.\u0026#xa0;Esto afecta a D6100 versiones anteriores a 1.0.0.63, R7800 versiones anteriores a 1.0.2.60, R8900 versiones anteriores a 1.0.4.26, R9000 versiones anteriores a 1.0.4.26, RBK20 versiones anteriores a 2.3.0.28, RBR20 versiones anteriores a 2.3.0.28, RBS20 versiones anteriores a 2.3.0.28, RBK50 versiones anteriores a 2.3.0.32, RBR50 versiones anteriores a 2.3.0.32, RBS50 versiones anteriores a 2.3.0.32, RBK40 versiones anteriores a 2.3.0.28, RBR40 versiones anteriores a 2.3.0.28, RBS40 versiones anteriores a 2.3.0.28, SRK60 versiones anteriores a 2.2.2.20, SRR60 versiones anteriores a 2.2.2.20, SRS60 versiones anteriores a 2.2.2.20, WN3000RPv2 versiones anteriores a 1.0.0.78, WNDR4300v2 versiones anteriores a 1.0.0.58, WNDR4500v3 versiones anteriores a 1.0.0.58, WNR2000v5 versiones anteriores a 1.0.0.70, XR450 versiones anteriores a 2.3.2.40 y XR500 versiones anteriores a 2.3.2.40" } ], "id": "CVE-2020-26913", "lastModified": "2024-11-21T05:20:28.870", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-10-09T07:15:17.043", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062340/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-WiFi-Systems-PSV-2018-0140" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062340/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-WiFi-Systems-PSV-2018-0140" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C8A5E09-861A-4C5F-8C0A-96803782E9EF", "versionEndExcluding": "1.0.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*", "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33C16A69-C930-4DA3-8750-EB50F2827731", "versionEndExcluding": "1.0.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9FCEBCD7-1D0D-47F6-BC72-A53BFBF3662D", "versionEndExcluding": "1.1.00.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6200:-:*:*:*:*:*:*:*", "matchCriteriaId": "00E6A1B7-4732-4259-9B71-10FF0B56A16B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4B185396-F010-45EF-B533-0AD61C095273", "versionEndExcluding": "1.0.0.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3EEA190-2E9C-4586-BF81-B115532FBA23", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "58E68C65-9685-40E8-8D51-6C922232168B", "versionEndExcluding": "1.0.0.86", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "7D30939B-86E3-4C78-9B05-686B4994C8B9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "53F5A909-D848-494E-9EB9-B794515372E2", "versionEndExcluding": "1.0.1.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "AF04B65B-9685-4595-9C71-0F77AD7109BE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "80764A3F-A007-44A8-A43C-55C918B5BBA5", "versionEndExcluding": "1.0.0.53", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "6DC6BD34-1A2C-4247-A20C-0B44C0F56E0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C35893A-C6C2-45C7-B3AF-BCFA62381BE5", "versionEndExcluding": "1.0.1.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C329B7CB-1281-480D-BDDB-E222044D715E", "versionEndExcluding": "1.0.3.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "814A0114-9A1D-4EA0-9AF4-6968514E4F01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dc112a_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDF9C0E1-7128-4052-B05E-3DD3394208A0", "versionEndExcluding": "1.0.0.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dc112a:-:*:*:*:*:*:*:*", "matchCriteriaId": "F87FFC46-137D-45B8-B437-F15565FB33D0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgn2200v4_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D4B3A29A-7C13-4B36-B14A-A7B6243F8034", "versionEndExcluding": "1.0.0.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgn2200v4:-:*:*:*:*:*:*:*", "matchCriteriaId": "0BE59214-C8A1-4337-A54C-E4E8C149B241", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgn2200bv4_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1406A926-8DBA-43B3-A0D7-BF4C9F991FDB", "versionEndExcluding": "1.0.0.109", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgn2200bv4:-:*:*:*:*:*:*:*", "matchCriteriaId": "9C78A475-9DDF-432B-A94A-01EFAC7DC70D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dm200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6B27650A-B7FE-41E4-8231-9283CC7B8349", "versionEndExcluding": "1.0.0.61", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dm200:-:*:*:*:*:*:*:*", "matchCriteriaId": "1B048F71-70F1-4D9F-84E2-9F7340F6ADAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0864CF6F-C025-44FE-B00F-83E14ACE1F8F", "versionEndExcluding": "1.0.0.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*", "matchCriteriaId": "CDAA5899-B73C-4690-853E-B5400F034BE1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B760484C-0D85-49BF-AA5D-2DB0A3A5D7E6", "versionEndExcluding": "1.0.0.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*", "matchCriteriaId": "CC5488D9-651C-4BAB-A141-06B816690D42", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D508F3C7-5A18-4983-8A30-755EA1F99DC5", "versionEndExcluding": "1.0.0.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*", "matchCriteriaId": "8C6DFDB6-1D7A-459A-8D30-FD4900ED718B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "18C88DDC-92C2-400E-8269-88A0EA65A98A", "versionEndExcluding": "1.0.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*", "matchCriteriaId": "305E295C-9C73-4798-A0BE-7973E1EE5EAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B2263B13-89CF-475E-ABE0-062783D924F7", "versionEndExcluding": "1.0.1.78", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F45B620-60B8-40F3-A055-181ADD71EFFF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:pr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "50E2E26A-200E-4D00-9657-034EACE3944F", "versionEndExcluding": "1.0.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:pr2000:-:*:*:*:*:*:*:*", "matchCriteriaId": "2451CC0C-71B2-474D-93F0-2B2ACD802FE3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "79B24229-6AC2-489D-B542-4DAA7E630180", "versionEndExcluding": "1.1.0.100", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "B131B5C8-CB7F-433B-BA32-F05CE0E92A66", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6230_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2B5B842D-2275-4968-997B-A70A67CBDBEC", "versionEndExcluding": "1.1.0.100", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6230:-:*:*:*:*:*:*:*", "matchCriteriaId": "C91CADFA-59DB-4B6C-A914-848884F4A4BD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6250_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E1DD1F7D-7556-4B95-A33F-E389948D20AA", "versionEndExcluding": "1.0.4.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6250:-:*:*:*:*:*:*:*", "matchCriteriaId": "321BE843-52C4-4638-A321-439CA7B3A6F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6300v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "34450066-658C-49CC-A853-2FA99ACAB205", "versionEndExcluding": "1.0.4.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6300v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "7909744D-FE9B-49D1-ADB3-029CCC432A47", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8BF91E85-8869-4421-8748-C7856C06435B", "versionEndExcluding": "1.0.1.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E4CDF6B-3829-44D0-9675-71D7BE83CAA2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D075FD21-C022-4246-8465-4EF79BADD29C", "versionEndExcluding": "1.0.2.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "AFE6B3A8-0601-44EA-AD9B-3BDDE6654FDF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AD6FD0FE-1431-4E39-8D07-B4AFE5BDB1B6", "versionEndExcluding": "1.0.2.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:-:*:*:*:*:*:*:*", "matchCriteriaId": "21B27F11-4262-4CE1-8107-B365A7C152F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700v3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D295754-5385-48CF-B354-3D3E5C53B1B2", "versionEndExcluding": "1.0.2.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700v3:-:*:*:*:*:*:*:*", "matchCriteriaId": "C88DA385-5FAE-49EC-80D6-78F81E7EEC16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5BB97877-F16D-4A9F-A130-9623A92C28DE", "versionEndExcluding": "1.0.2.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0794BB7C-1BCF-4F08-8EB2-9C3B150C105A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E453D3AE-A218-4791-BB19-79C2CF6EC6F8", "versionEndExcluding": "1.0.9.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0870C337-6BCE-4197-A9DE-6CED2B45AD58", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*", "matchCriteriaId": "366FA778-3C2A-42AF-9141-DAD7043B406C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B9F6D3F1-4064-4CAD-85D4-E1B2E72B440C", "versionEndExcluding": "1.0.3.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "2BCA6487-57EC-4630-884F-820BBFE25843", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8B02CB0A-BBB8-4A64-93B3-7CA1DF7B7299", "versionEndExcluding": "1.4.1.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9D3F1622-F2B7-41F0-87F0-61F4ACB270C8", "versionEndExcluding": "1.4.1.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E5AC056A-DF92-4CA7-9919-2C9BDAE3C32D", "versionEndExcluding": "1.0.4.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F1F914AD-70DC-47F5-A2F7-672DBE89C62E", "versionEndExcluding": "1.0.4.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "448D7EA1-A7BB-4AA5-8260-1D533D6A99AC", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk20:-:*:*:*:*:*:*:*", "matchCriteriaId": "E6C9F31C-3E12-4787-9C9B-14883D9D152A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1CC5263E-71E4-4B63-AD77-D1E72DC704B0", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk40:-:*:*:*:*:*:*:*", "matchCriteriaId": "12DDD83C-6FF1-433F-ACA1-7B4B147F9A8C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BA9F2B44-4114-495A-B200-B703FDFC3F8F", "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk50:-:*:*:*:*:*:*:*", "matchCriteriaId": "8BA66D07-D017-49D6-8E72-5C48E940DE1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1525B9D0-B147-437D-ACAE-58819A1F4FC6", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr20:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE5DBD66-9C2A-4EFF-87AB-03E791D584B5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D130E198-E9F5-4250-9C52-E39DF5C96711", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "A9E20E59-2B1E-4E43-A494-2C20FD716D4F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A25B8627-D325-493B-8B7D-4F900334F0D8", "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr50:-:*:*:*:*:*:*:*", "matchCriteriaId": "B2CAEA32-6934-4743-9E6B-22D52AC5E7F8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4515F985-B714-480C-8FBA-2499A29F29FA", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs20:-:*:*:*:*:*:*:*", "matchCriteriaId": "14FC7F5B-7E4F-4A68-8427-D1F553EBE8CA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "08426AC6-4811-43E8-87EB-204A2729C49B", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40:-:*:*:*:*:*:*:*", "matchCriteriaId": "6FDCDE39-0355-43B9-BF57-F3718DA2988D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81ED6C61-2A7C-49EC-BD3D-466442EF715C", "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs50:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BCFD959-D522-4FA0-AD01-2937DAEE1EDF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rpv2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AA82BFA7-9B98-408C-BE81-E8D7532780A2", "versionEndExcluding": "1.0.0.78", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rpv2:-:*:*:*:*:*:*:*", "matchCriteriaId": "50BC8FA2-F9D5-4286-97DD-BD2A55EA234D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000v5_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8D1EF946-5FEF-4DD7-8567-CB435FAA41E2", "versionEndExcluding": "1.0.0.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000v5_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "F024A464-DB7D-4F6E-A951-3D8068F86470", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3400v3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C3B2795-B3B0-4709-B37B-46A713BCCABE", "versionEndExcluding": "1.0.1.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3400v3:-:*:*:*:*:*:*:*", "matchCriteriaId": "37F227D8-332F-4D24-BAEA-AA5DB3E3EC95", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2020_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E0141851-BE96-4F6A-883F-3B20AE6945C1", "versionEndExcluding": "1.1.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2020:-:*:*:*:*:*:*:*", "matchCriteriaId": "C2189628-03E7-445A-9EF2-656A85539115", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr3500lv2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F667392E-F63E-4186-9BA3-7F9A4AA3EC67", "versionEndExcluding": "1.2.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr3500lv2:-:*:*:*:*:*:*:*", "matchCriteriaId": "FC3F6D58-D900-41B4-8626-58928866208A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr450_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7284BC09-A244-4F2F-A02A-34C0F5CA64EE", "versionEndExcluding": "2.3.2.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr450:-:*:*:*:*:*:*:*", "matchCriteriaId": "66B9CE4D-D1EC-4F55-8226-D159CF5F3AB6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AA9B22EF-5791-41DB-8CC1-A1B60CF4A73F", "versionEndExcluding": "2.3.2.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr500:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E203D92-F97B-4F5B-B395-3A5DEDBF1C1C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D3600 before 1.0.0.72, D6000 before 1.0.0.72, D6200 before 1.1.00.34, D6220 before 1.0.0.52, D6400 before 1.0.0.86, D7000 before 1.0.1.74, D7000v2 before 1.0.0.53, D7800 before 1.0.1.56, D8500 before 1.0.3.44, DC112A before 1.0.0.42, DGN2200v4 before 1.0.0.110, DGND2200Bv4 before 1.0.0.109, DM200 before 1.0.0.61, EX3700 before 1.0.0.76, EX3800 before 1.0.0.76, EX6120 before 1.0.0.46, EX6130 before 1.0.0.28, EX7000 before 1.0.1.78, PR2000 before 1.0.0.28, R6220 before 1.1.0.100, R6230 before 1.1.0.100, R6250 before 1.0.4.34, R6300v2 before 1.0.4.34, R6400 before 1.0.1.46, R6400v2 before 1.0.2.66, R6700 before 1.0.2.6, R6700v3 before 1.0.2.66, R6900 before 1.0.2.6, R7000 before 1.0.9.34, R7100LG before 1.0.0.50, R7500v2 before 1.0.3.40, R7900P before 1.4.1.50, R8000P before 1.4.1.50, R8900 before 1.0.4.12, R9000 before 1.0.4.12, RBK20 before 2.3.0.28, RBK40 before 2.3.0.28, RBK50 before 2.3.0.32, RBR20 before 2.3.0.28, RBR40 before 2.3.0.28, RBR50 before 2.3.0.32, RBS20 before 2.3.0.28, RBS40 before 2.3.0.28, RBS50 before 2.3.0.32, WN3000RPv2 before 1.0.0.78, WNDR3400v3 before 1.0.1.24, WNR2000v5 before 1.0.0.70, WNR2020 before 1.1.0.62, WNR3500Lv2 before 1.2.0.62, XR450 before 2.3.2.56, and XR500 before 2.3.2.56." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una configuraci\u00f3n incorrecta de los ajustes de seguridad. Esto afecta a D3600 versiones anteriores a 1.0.0.72, al D6000 versiones anteriores a 1.0.0.72, al D6200 versiones anteriores a 1.1.00.34, al D6220 versiones anteriores a 1.0.0.52, al D6400 versiones anteriores a 1.0.0.86, a D7000 versiones anteriores a 1.0.1.74, a D7000v2 versiones anteriores a 1.0.0.53, a D7800 versiones anteriores a 1.0.0.53. 0.0.53, D7800 versiones anteriores a 1.0.1.56, D8500 versiones anteriores a 1.0.3.44, DC112A versiones anteriores a 1.0.0.42, DGN2200v4 versiones anteriores a 1.0.0.110, DGND2200Bv4 versiones anteriores a 1.0.0.109, DM200 versiones anteriores a 1. 0.0.61, EX3700 versiones anteriores a 1.0.0.76, EX3800 versiones anteriores a 1.0.0.76, EX6120 versiones anteriores a 1.0.0.46, EX6130 versiones anteriores a 1.0.0.28, EX7000 versiones anteriores a 1.0.1.78, PR2000 versiones anteriores a 1.0.0. 28, R6220 versiones anteriores a 1.1.0.100, R6230 versiones anteriores a 1.1.0.100, R6250 versiones anteriores a 1.0.4.34, R6300v2 versiones anteriores a 1.0.4.34, R6400 versiones anteriores a 1.0.1.46, R6400v2 versiones anteriores a 1.0.2.66, R6700 versiones anteriores a 1. 0.2.6, R6700v3 versiones anteriores a 1.0.2.66, R6900 versiones anteriores a 1.0.2.6, R7000 versiones anteriores a 1.0.9.34, R7100LG versiones anteriores a 1.0.0.50, R7500v2 versiones anteriores a 1.0.3.40, R7900P versiones anteriores a 1.4.1. 50, R8000P versiones anteriores a 1.4.1.50, R8900 versiones anteriores a 1.0.4.12, R9000 versiones anteriores a 1.0.4.12, RBK20 versiones anteriores a 2.3.0.28, RBK40 versiones anteriores a 2.3.0.28, RBK50 versiones anteriores a 2.3.0.32, RBR20 versiones anteriores a 2. 3.0.28, RBR40 versiones anteriores a 2.3.0.28, RBR50 versiones anteriores a 2.3.0.32, RBS20 versiones anteriores a 2.3.0.28, RBS40 versiones anteriores a 2.3.0.28, RBS50 versiones anteriores a 2.3.0.32, WN3000RPv2 versiones anteriores a 1.0.0. 78, WNDR3400v3 versiones anteriores a 1.0.1.24, WNR2000v5 versiones anteriores a 1.0.0.70, WNR2020 versiones anteriores a 1.1.0.62, WNR3500Lv2 versiones anteriores a 1.2.0.62, XR450 versiones anteriores a 2.3.2.56 y XR500 versiones anteriores a 2.3.2.56" } ], "id": "CVE-2021-45640", "lastModified": "2024-11-21T06:32:45.090", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 3.9, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" }, "exploitabilityScore": 0.5, "impactScore": 3.4, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:19.643", "references": [ { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064045/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2018-0228" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064045/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2018-0228" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }