Vulnerabilites related to smart-hmi - webiq
Vulnerability from fkie_nvd
Published
2024-09-16 16:15
Modified
2024-09-20 22:42
Severity ?
Summary
The Windows version of WebIQ 2.15.9 is affected by a directory traversal vulnerability that allows remote attackers to read any file on the system.
References
▼ | URL | Tags | |
---|---|---|---|
vulnreport@tenable.com | https://www.tenable.com/security/research/tra-2024-38 | Exploit, Third Party Advisory |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:smart-hmi:webiq:2.15.9:*:*:*:*:*:*:*", "matchCriteriaId": "7A6F0FDE-434D-4614-B510-D6D5C3C1E4B0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:*", "matchCriteriaId": "A2572D17-1DE6-457B-99CC-64AFD54487EA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "The Windows version of WebIQ 2.15.9 is affected by a directory traversal vulnerability that allows remote attackers to read any file on the system." }, { "lang": "es", "value": "La versi\u00f3n para Windows de WebIQ 2.15.9 se ve afectada por una vulnerabilidad de directory traversal que permite a atacantes remotos leer cualquier archivo del sistema." } ], "id": "CVE-2024-8752", "lastModified": "2024-09-20T22:42:20.367", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "automatable": "NOT_DEFINED", "availabilityRequirements": "NOT_DEFINED", "baseScore": 9.3, "baseSeverity": "CRITICAL", "confidentialityRequirements": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirements": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubsequentSystemAvailability": "NOT_DEFINED", "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED", "modifiedSubsequentSystemIntegrity": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnerableSystemAvailability": "NOT_DEFINED", "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED", "modifiedVulnerableSystemIntegrity": "NOT_DEFINED", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "recovery": "NOT_DEFINED", "safety": "NOT_DEFINED", "subsequentSystemAvailability": "HIGH", "subsequentSystemConfidentiality": "HIGH", "subsequentSystemIntegrity": "HIGH", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnerabilityResponseEffort": "NOT_DEFINED", "vulnerableSystemAvailability": "NONE", "vulnerableSystemConfidentiality": "HIGH", "vulnerableSystemIntegrity": "NONE" }, "source": "vulnreport@tenable.com", "type": "Secondary" } ] }, "published": "2024-09-16T16:15:14.040", "references": [ { "source": "vulnreport@tenable.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://www.tenable.com/security/research/tra-2024-38" } ], "sourceIdentifier": "vulnreport@tenable.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-22" } ], "source": "vulnreport@tenable.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-22" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
cve-2024-8752
Vulnerability from cvelistv5
Published
2024-09-16 15:42
Modified
2024-09-16 16:07
Severity ?
EPSS score ?
Summary
The Windows version of WebIQ 2.15.9 is affected by a directory traversal vulnerability that allows remote attackers to read any file on the system.
References
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:beijerelectronics:webiq:2.15.19:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "webiq", "vendor": "beijerelectronics", "versions": [ { "status": "affected", "version": "2.15.19" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-8752", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-09-16T15:56:56.454077Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-09-16T16:07:21.866Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "collectionURL": "https://www.smart-hmi.com/", "defaultStatus": "unaffected", "platforms": [ "Windows" ], "product": "WebIQ", "vendor": "Smart HMI", "versions": [ { "status": "affected", "version": "2.15.19" } ] } ], "datePublic": "2024-09-12T17:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "The Windows version of WebIQ 2.15.9 is affected by a directory traversal vulnerability that allows remote attackers to read any file on the system." } ], "value": "The Windows version of WebIQ 2.15.9 is affected by a directory traversal vulnerability that allows remote attackers to read any file on the system." } ], "impacts": [ { "capecId": "CAPEC-126", "descriptions": [ { "lang": "en", "value": "CAPEC-126 Path Traversal" } ] } ], "metrics": [ { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 9.3, "baseSeverity": "CRITICAL", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "HIGH", "subConfidentialityImpact": "HIGH", "subIntegrityImpact": "HIGH", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:H/SI:H/SA:H", "version": "4.0", "vulnAvailabilityImpact": "NONE", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "NONE", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-22", "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-16T15:42:20.153Z", "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be", "shortName": "tenable" }, "references": [ { "url": "https://www.tenable.com/security/research/tra-2024-38" } ], "source": { "discovery": "UNKNOWN" }, "title": "WebIQ 2.15.9 Runtime on Windows - Directory Traversal Vulnerability", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be", "assignerShortName": "tenable", "cveId": "CVE-2024-8752", "datePublished": "2024-09-16T15:42:20.153Z", "dateReserved": "2024-09-12T13:59:13.908Z", "dateUpdated": "2024-09-16T16:07:21.866Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }