Vulnerabilites related to fujielectric - v-server
Vulnerability from fkie_nvd
Published
2018-09-26 20:29
Modified
2024-11-21 03:49
Severity ?
Summary
Fuji Electric V-Server 4.0.3.0 and prior, An out-of-bounds read vulnerability has been identified, which may allow remote code execution.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:fujielectric:v-server_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "09EDDB15-323C-4ED5-8288-5297D7396F09",
              "versionEndIncluding": "4.0.3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:fujielectric:v-server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "10FE5445-2A67-4B12-8A38-B960E6002340",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Fuji Electric V-Server 4.0.3.0 and prior, An out-of-bounds read vulnerability has been identified, which may allow remote code execution."
    },
    {
      "lang": "es",
      "value": "En Fuji Electric V-Server en versiones 4.0.3.0 y anteriores, se ha identificado una vulnerabilidad de lectura fuera de l\u00edmites que podr\u00eda permitir la ejecuci\u00f3n remota de c\u00f3digo."
    }
  ],
  "id": "CVE-2018-14819",
  "lastModified": "2024-11-21T03:49:51.803",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-09-26T20:29:00.870",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/105341"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/105341"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-01-03 03:15
Modified
2024-11-21 07:31
Summary
Out-of-bounds write vulnerability in V-Server v4.0.12.0 and earlier allows a local attacker to obtain the information and/or execute arbitrary code by having a user to open a specially crafted project file.
Impacted products
Vendor Product Version
fujielectric v-server *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "592FDE74-EB5F-4AD2-9F0B-5D021EB48C1E",
              "versionEndIncluding": "4.0.12.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Out-of-bounds write vulnerability in V-Server v4.0.12.0 and earlier allows a local attacker to obtain the information and/or execute arbitrary code by having a user to open a specially crafted project file."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad de escritura fuera de los l\u00edmites en V-Server v4.0.12.0 y versiones anteriores permite a un atacante local obtener la informaci\u00f3n y/o ejecutar c\u00f3digo arbitrario haciendo que un usuario abra un archivo de proyecto especialmente manipulado."
    }
  ],
  "id": "CVE-2022-47317",
  "lastModified": "2024-11-21T07:31:42.540",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-01-03T03:15:10.857",
  "references": [
    {
      "source": "vultures@jpcert.or.jp",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://jvn.jp/en/vu/JVNVU92811888/index.html"
    },
    {
      "source": "vultures@jpcert.or.jp",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://jvn.jp/en/vu/JVNVU92811888/index.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php"
    }
  ],
  "sourceIdentifier": "vultures@jpcert.or.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-06-19 05:15
Modified
2024-12-23 22:15
Summary
Stack-based buffer overflow vulnerability in V-Server v4.0.15.0 and V-Server Lite v4.0.15.0 and earlier allows an attacker to execute arbitrary code by having user open a specially crafted VPR file.
Impacted products
Vendor Product Version
fujielectric v-server 4.0.15.0
fujielectric v-server 4.0.15.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:4.0.15.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "6829D22F-B9E2-4842-AC8D-AEAD5AF80374",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:4.0.15.0:*:*:*:lite:*:*:*",
              "matchCriteriaId": "7970AA8A-FBB8-4C66-906A-23EB685D93D9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Stack-based buffer overflow vulnerability in V-Server v4.0.15.0 and V-Server Lite v4.0.15.0 and earlier allows an attacker to execute arbitrary code by having user open a specially crafted VPR file."
    }
  ],
  "id": "CVE-2023-31239",
  "lastModified": "2024-12-23T22:15:06.137",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2023-06-19T05:15:09.330",
  "references": [
    {
      "source": "vultures@jpcert.or.jp",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/en/vu/JVNVU98818508/"
    },
    {
      "source": "vultures@jpcert.or.jp",
      "tags": [
        "Release Notes"
      ],
      "url": "https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/en/vu/JVNVU98818508/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Release Notes"
      ],
      "url": "https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php"
    }
  ],
  "sourceIdentifier": "vultures@jpcert.or.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2019-11-13 23:15
Modified
2024-11-21 04:32
Severity ?
Summary
In Fuji Electric V-Server 4.0.6 and prior, several heap-based buffer overflows have been identified, which may allow an attacker to remotely execute arbitrary code.
References
Impacted products
Vendor Product Version
fujielectric v-server *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1B36DE01-D103-46C0-AF50-8F783AC8DE55",
              "versionEndIncluding": "4.0.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "In Fuji Electric V-Server 4.0.6 and prior, several heap-based buffer overflows have been identified, which may allow an attacker to remotely execute arbitrary code."
    },
    {
      "lang": "es",
      "value": "En Fuji Electric V-Server versi\u00f3n 4.0.6 y anteriores, se han identificado varios desbordamientos de b\u00fafer en la regi\u00f3n heap de la memoria, lo que puede permitir a un atacante ejecutar c\u00f3digo arbitrario remotamente."
    }
  ],
  "id": "CVE-2019-18240",
  "lastModified": "2024-11-21T04:32:54.107",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-11-13T23:15:11.433",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.us-cert.gov/ics/advisories/icsa-19-311-02"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.us-cert.gov/ics/advisories/icsa-19-311-02"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-122"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-06-14 09:15
Modified
2024-11-21 06:59
Summary
Out-of-bounds read vulnerability exist in the simulator module contained in the graphic editor 'V-SFT' v6.1.3.0 and earlier, which may allow an attacker to obtain information and/or execute arbitrary code by having a user to open a specially crafted image file.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:-:*:*:*",
              "matchCriteriaId": "8DEBCE19-6F6B-4759-94CD-28BC07DE44BB",
              "versionEndExcluding": "4.0.12.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "5CD30EBE-44A0-4DBC-A0C5-23BBC1D6B4FF",
              "versionEndExcluding": "4.0.13.0a",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fujielectric:v-sft:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6341937E-A481-4A09-9432-3278A4EA08FD",
              "versionEndExcluding": "6.1.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Out-of-bounds read vulnerability exist in the simulator module contained in the graphic editor \u0027V-SFT\u0027 v6.1.3.0 and earlier, which may allow an attacker to obtain information and/or execute arbitrary code by having a user to open a specially crafted image file."
    },
    {
      "lang": "es",
      "value": "Se presenta una vulnerabilidad de lectura fuera de l\u00edmites en el m\u00f3dulo simulador contenido en el editor gr\u00e1fico \"V-SFT\" versiones v6.1.3.0 y anteriores, que puede permitir a un atacante obtener informaci\u00f3n y/o ejecutar c\u00f3digo arbitrario haciendo que un usuario abra un archivo de imagen especialmente dise\u00f1ado"
    }
  ],
  "id": "CVE-2022-29506",
  "lastModified": "2024-11-21T06:59:12.933",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-06-14T09:15:09.573",
  "references": [
    {
      "source": "vultures@jpcert.or.jp",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/en/vu/JVNVU93134398/index.html"
    },
    {
      "source": "vultures@jpcert.or.jp",
      "tags": [
        "Release Notes",
        "Vendor Advisory"
      ],
      "url": "https://monitouch.fujielectric.com/site/download-e/09vsft6_inf/Search.php"
    },
    {
      "source": "vultures@jpcert.or.jp",
      "tags": [
        "Release Notes",
        "Vendor Advisory"
      ],
      "url": "https://monitouch.fujielectric.com/site/download-eu/03tellus_inf/index.php"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/en/vu/JVNVU93134398/index.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Release Notes",
        "Vendor Advisory"
      ],
      "url": "https://monitouch.fujielectric.com/site/download-e/09vsft6_inf/Search.php"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Release Notes",
        "Vendor Advisory"
      ],
      "url": "https://monitouch.fujielectric.com/site/download-eu/03tellus_inf/index.php"
    }
  ],
  "sourceIdentifier": "vultures@jpcert.or.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-11-15 06:15
Modified
2024-11-21 08:30
Summary
Out-of-bounds write vulnerability exists in V-Server V4.0.18.0 and earlier and V-Server Lite V4.0.18.0 and earlier. If a user opens a specially crafted VPR file, information may be disclosed and/or arbitrary code may be executed.
Impacted products
Vendor Product Version
fujielectric v-server *
fujielectric v-server *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:-:*:*:*",
              "matchCriteriaId": "64415646-1087-4D64-B9D5-9BC3B46B8FA8",
              "versionEndIncluding": "4.0.18.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "6ABDE61D-26F7-4F70-90AE-E67A10DCA794",
              "versionEndIncluding": "4.0.18.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Out-of-bounds write vulnerability exists in V-Server V4.0.18.0 and earlier and V-Server Lite V4.0.18.0 and earlier. If a user opens a specially crafted VPR file, information may be disclosed and/or arbitrary code may be executed.\r\n"
    },
    {
      "lang": "es",
      "value": "Existe una vulnerabilidad de escritura fuera de los l\u00edmites en V-Server V4.0.18.0 y anteriores y en V-Server Lite V4.0.18.0 y anteriores. Si un usuario abre un archivo VPR especialmente manipulado, se puede revelar informaci\u00f3n y/o se puede ejecutar c\u00f3digo arbitrario."
    }
  ],
  "id": "CVE-2023-47584",
  "lastModified": "2024-11-21T08:30:30.513",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-11-15T06:15:28.213",
  "references": [
    {
      "source": "vultures@jpcert.or.jp",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://hakko-elec.co.jp/site/download/03tellus_inf/index.php"
    },
    {
      "source": "vultures@jpcert.or.jp",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/en/vu/JVNVU93840158/"
    },
    {
      "source": "vultures@jpcert.or.jp",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://hakko-elec.co.jp/site/download/03tellus_inf/index.php"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/en/vu/JVNVU93840158/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php"
    }
  ],
  "sourceIdentifier": "vultures@jpcert.or.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-06-14 09:15
Modified
2024-11-21 06:59
Summary
Out-of-bounds write vulnerability exists in V-Server v4.0.11.0 and earlier and V-Server Lite v4.0.13.0 and earlier, which may allow an attacker to obtain information and/or execute arbitrary code by having a user to open a specially crafted image file.
Impacted products
Vendor Product Version
fujielectric v-server *
fujielectric v-server *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:-:*:*:*",
              "matchCriteriaId": "C8CAC48D-A08C-4DEC-A461-A2D3F3C499E6",
              "versionEndIncluding": "4.0.11.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "77C20BDF-C278-4D79-BE4D-583AA99AC21C",
              "versionEndIncluding": "4.0.13.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Out-of-bounds write vulnerability exists in V-Server v4.0.11.0 and earlier and V-Server Lite v4.0.13.0 and earlier, which may allow an attacker to obtain information and/or execute arbitrary code by having a user to open a specially crafted image file."
    },
    {
      "lang": "es",
      "value": "Se presenta una vulnerabilidad de escritura fuera de l\u00edmites en V-Server versiones v4.0.11.0 y anteriores y V-Server Lite versiones v4.0.13.0 y anteriores, que puede permitir a un atacante obtener informaci\u00f3n y/o ejecutar c\u00f3digo arbitrario haciendo que un usuario abra un archivo de imagen especialmente dise\u00f1ado"
    }
  ],
  "id": "CVE-2022-29524",
  "lastModified": "2024-11-21T06:59:15.343",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-06-14T09:15:09.700",
  "references": [
    {
      "source": "vultures@jpcert.or.jp",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/en/vu/JVNVU93134398/index.html"
    },
    {
      "source": "vultures@jpcert.or.jp",
      "tags": [
        "Release Notes",
        "Vendor Advisory"
      ],
      "url": "https://monitouch.fujielectric.com/site/download-e/09vsft6_inf/Search.php"
    },
    {
      "source": "vultures@jpcert.or.jp",
      "tags": [
        "Release Notes",
        "Vendor Advisory"
      ],
      "url": "https://monitouch.fujielectric.com/site/download-eu/03tellus_inf/index.php"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/en/vu/JVNVU93134398/index.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Release Notes",
        "Vendor Advisory"
      ],
      "url": "https://monitouch.fujielectric.com/site/download-e/09vsft6_inf/Search.php"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Release Notes",
        "Vendor Advisory"
      ],
      "url": "https://monitouch.fujielectric.com/site/download-eu/03tellus_inf/index.php"
    }
  ],
  "sourceIdentifier": "vultures@jpcert.or.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2018-09-13 19:29
Modified
2024-11-21 03:41
Summary
A maliciously crafted project file may cause a buffer overflow, which may allow the attacker to execute arbitrary code that affects Fuji Electric V-Server Lite 4.0.3.0 and prior.
References
Impacted products
Vendor Product Version
fujielectric v-server *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "7E1A7C4D-BCE2-4532-9278-F02C98C19AD9",
              "versionEndIncluding": "4.0.3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A maliciously crafted project file may cause a buffer overflow, which may allow the attacker to execute arbitrary code that affects Fuji Electric V-Server Lite 4.0.3.0 and prior."
    },
    {
      "lang": "es",
      "value": "Un archivo de proyecto maliciosamente manipulado podr\u00eda provocar un desbordamiento de b\u00fafer, lo que podr\u00eda permitir que el atacante ejecute c\u00f3digo arbitrario que afecta a Fuji Electric V-Server Lite 4.0.3.0 y anteriores."
    }
  ],
  "id": "CVE-2018-10637",
  "lastModified": "2024-11-21T03:41:42.753",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-09-13T19:29:00.277",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/105328"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource",
        "VDB Entry"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-02"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/105328"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource",
        "VDB Entry"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-02"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-120"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-01-03 03:15
Modified
2024-11-21 07:23
Summary
Out-of-bounds read vulnerability in V-Server v4.0.12.0 and earlier allows a local attacker to obtain the information and/or execute arbitrary code by having a user to open a specially crafted project file.
Impacted products
Vendor Product Version
fujielectric v-server *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "592FDE74-EB5F-4AD2-9F0B-5D021EB48C1E",
              "versionEndIncluding": "4.0.12.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Out-of-bounds read vulnerability in V-Server v4.0.12.0 and earlier allows a local attacker to obtain the information and/or execute arbitrary code by having a user to open a specially crafted project file."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad de lectura fuera de los l\u00edmites en V-Server v4.0.12.0 y versiones anteriores permite a un atacante local obtener la informaci\u00f3n y/o ejecutar c\u00f3digo arbitrario haciendo que un usuario abra un archivo de proyecto especialmente manipulado."
    }
  ],
  "id": "CVE-2022-41645",
  "lastModified": "2024-11-21T07:23:33.400",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-01-03T03:15:10.047",
  "references": [
    {
      "source": "vultures@jpcert.or.jp",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://jvn.jp/en/vu/JVNVU92811888/index.html"
    },
    {
      "source": "vultures@jpcert.or.jp",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://jvn.jp/en/vu/JVNVU92811888/index.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php"
    }
  ],
  "sourceIdentifier": "vultures@jpcert.or.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-06-14 09:15
Modified
2024-11-21 06:59
Summary
Use after free vulnerability exists in the simulator module contained in the graphic editor 'V-SFT' versions prior to v6.1.6.0, which may allow an attacker to obtain information and/or execute arbitrary code by having a user to open a specially crafted image file.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:-:*:*:*",
              "matchCriteriaId": "8DEBCE19-6F6B-4759-94CD-28BC07DE44BB",
              "versionEndExcluding": "4.0.12.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "5CD30EBE-44A0-4DBC-A0C5-23BBC1D6B4FF",
              "versionEndExcluding": "4.0.13.0a",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fujielectric:v-sft:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6341937E-A481-4A09-9432-3278A4EA08FD",
              "versionEndExcluding": "6.1.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Use after free vulnerability exists in the simulator module contained in the graphic editor \u0027V-SFT\u0027 versions prior to v6.1.6.0, which may allow an attacker to obtain information and/or execute arbitrary code by having a user to open a specially crafted image file."
    },
    {
      "lang": "es",
      "value": "Se presenta una vulnerabilidad de uso de memoria previamente liberada en el m\u00f3dulo simulador contenido en el editor gr\u00e1fico \"V-SFT\" versiones anteriores a v6.1.6.0, que puede permitir a un atacante obtener informaci\u00f3n y/o ejecutar c\u00f3digo arbitrario haciendo que un usuario abra un archivo de imagen especialmente dise\u00f1ado"
    }
  ],
  "id": "CVE-2022-29522",
  "lastModified": "2024-11-21T06:59:15.127",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-06-14T09:15:09.657",
  "references": [
    {
      "source": "vultures@jpcert.or.jp",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/en/vu/JVNVU99188133/index.html"
    },
    {
      "source": "vultures@jpcert.or.jp",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://monitouch.fujielectric.com/site/download-e/09vsft6_inf/Search.php"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/en/vu/JVNVU99188133/index.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://monitouch.fujielectric.com/site/download-e/09vsft6_inf/Search.php"
    }
  ],
  "sourceIdentifier": "vultures@jpcert.or.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-416"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2018-09-26 20:29
Modified
2024-11-21 03:49
Severity ?
Summary
Fuji Electric V-Server 4.0.3.0 and prior, Several out-of-bounds write vulnerabilities have been identified, which may allow remote code execution.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:fujielectric:v-server_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "09EDDB15-323C-4ED5-8288-5297D7396F09",
              "versionEndIncluding": "4.0.3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:fujielectric:v-server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "10FE5445-2A67-4B12-8A38-B960E6002340",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Fuji Electric V-Server 4.0.3.0 and prior, Several out-of-bounds write vulnerabilities have been identified, which may allow remote code execution."
    },
    {
      "lang": "es",
      "value": "En Fuji Electric V-Server en versiones 4.0.3.0 y anteriores, se han identificado m\u00faltiples vulnerabilidades de escritura fuera de l\u00edmites que podr\u00edan permitir la ejecuci\u00f3n remota de c\u00f3digo."
    }
  ],
  "id": "CVE-2018-14815",
  "lastModified": "2024-11-21T03:49:51.263",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-09-26T20:29:00.620",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/105341"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/105341"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2018-09-26 20:29
Modified
2024-11-21 03:49
Severity ?
Summary
Fuji Electric V-Server 4.0.3.0 and prior, A stack-based buffer overflow vulnerability has been identified, which may allow remote code execution.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:fujielectric:v-server_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "09EDDB15-323C-4ED5-8288-5297D7396F09",
              "versionEndIncluding": "4.0.3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:fujielectric:v-server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "10FE5445-2A67-4B12-8A38-B960E6002340",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Fuji Electric V-Server 4.0.3.0 and prior, A stack-based buffer overflow vulnerability has been identified, which may allow remote code execution."
    },
    {
      "lang": "es",
      "value": "En Fuji Electric V-Server en versiones 4.0.3.0 y anteriores, se ha identificado una vulnerabilidad de desbordamiento de b\u00fafer basado en pila que podr\u00eda permitir la ejecuci\u00f3n remota de c\u00f3digo."
    }
  ],
  "id": "CVE-2018-14823",
  "lastModified": "2024-11-21T03:49:52.330",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-09-26T20:29:00.980",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/105341"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/105341"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-06-16 02:15
Modified
2024-11-21 07:02
Summary
Out-of-bounds read vulnerability exists in V-Server v4.0.11.0 and earlier and V-Server Lite v4.0.13.0 and earlier, which may allow an attacker to obtain information and/or execute arbitrary code by having a user to open a specially crafted image file.
Impacted products
Vendor Product Version
fujielectric v-server *
fujielectric v-server *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:-:*:*:*",
              "matchCriteriaId": "C8CAC48D-A08C-4DEC-A461-A2D3F3C499E6",
              "versionEndIncluding": "4.0.11.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "77C20BDF-C278-4D79-BE4D-583AA99AC21C",
              "versionEndIncluding": "4.0.13.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Out-of-bounds read vulnerability exists in V-Server v4.0.11.0 and earlier and V-Server Lite v4.0.13.0 and earlier, which may allow an attacker to obtain information and/or execute arbitrary code by having a user to open a specially crafted image file."
    },
    {
      "lang": "es",
      "value": "Se presenta una vulnerabilidad de lectura fuera de l\u00edmites en V-Server v4.0.11.0 y anteriores y V-Server Lite v4.0.13.0 y anteriores, que puede permitir a un atacante obtener informaci\u00f3n y/o ejecutar c\u00f3digo arbitrario haciendo que un usuario abra un archivo de imagen especialmente dise\u00f1ado"
    }
  ],
  "id": "CVE-2022-30549",
  "lastModified": "2024-11-21T07:02:55.347",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-06-16T02:15:09.353",
  "references": [
    {
      "source": "vultures@jpcert.or.jp",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/en/vu/JVNVU93134398/index.html"
    },
    {
      "source": "vultures@jpcert.or.jp",
      "tags": [
        "Release Notes",
        "Vendor Advisory"
      ],
      "url": "https://monitouch.fujielectric.com/site/download-e/09vsft6_inf/Search.php"
    },
    {
      "source": "vultures@jpcert.or.jp",
      "tags": [
        "Release Notes",
        "Vendor Advisory"
      ],
      "url": "https://monitouch.fujielectric.com/site/download-eu/03tellus_inf/index.php"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/en/vu/JVNVU93134398/index.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Release Notes",
        "Vendor Advisory"
      ],
      "url": "https://monitouch.fujielectric.com/site/download-e/09vsft6_inf/Search.php"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Release Notes",
        "Vendor Advisory"
      ],
      "url": "https://monitouch.fujielectric.com/site/download-eu/03tellus_inf/index.php"
    }
  ],
  "sourceIdentifier": "vultures@jpcert.or.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2017-07-17 19:29
Modified
2024-11-21 03:36
Summary
An issue was discovered in Fuji Electric V-Server Version 3.3.22.0 and prior. A memory corruption vulnerability has been identified (aka improper restriction of operations within the bounds of a memory buffer), which may allow remote code execution.
Impacted products
Vendor Product Version
fujielectric v-server *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6D77A1EB-BE7D-45FA-AF45-BC5F5286B573",
              "versionEndIncluding": "3.3.22.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered in Fuji Electric V-Server Version 3.3.22.0 and prior. A memory corruption vulnerability has been identified (aka improper restriction of operations within the bounds of a memory buffer), which may allow remote code execution."
    },
    {
      "lang": "es",
      "value": "Un problema fue descubierto en Fuji Electric V-Server en su versi\u00f3n 3.3.22.0 y anteriores. Una vulnerabilidad de corrupci\u00f3n de memoria ha sido identificada (Tambi\u00e9n conocido como restricci\u00f3n de operaciones inapropiada dentro de los l\u00edmites del buffer de la memoria), lo que podr\u00eda permitir ejecuci\u00f3n de c\u00f3digo remoto."
    }
  ],
  "id": "CVE-2017-9639",
  "lastModified": "2024-11-21T03:36:34.153",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "LOW",
          "baseScore": 7.3,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.4,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2017-07-17T19:29:00.340",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/99544"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-192-02"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/99544"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-192-02"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-01-27 20:15
Modified
2024-11-21 05:50
Summary
A heap-based buffer overflow issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0).
Impacted products
Vendor Product Version
fujielectric v-server *
fujielectric v-simulator *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "3D8B4395-7ADA-4752-9DFF-B83E054596E4",
              "versionEndExcluding": "4.0.10.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fujielectric:v-simulator:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "B5EB143F-D650-45F2-9948-B1C2246E56A0",
              "versionEndExcluding": "4.0.10.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A heap-based buffer overflow issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0)."
    },
    {
      "lang": "es",
      "value": "Se ha identificado un problema de desbordamiento del b\u00fafer en la regi\u00f3n heap de la memoria en la manera en que la aplicaci\u00f3n procesa archivos de proyecto, permitiendo a un atacante dise\u00f1ar un archivo de proyecto especial que puede permitir una ejecuci\u00f3n de c\u00f3digo arbitraria en el Tellus Lite V-Simulator y V-Server Lite (versiones anteriores a 4.0.10.0)"
    }
  ],
  "id": "CVE-2021-22641",
  "lastModified": "2024-11-21T05:50:22.220",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-01-27T20:15:13.207",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Exploit",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-099/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-099/"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-122"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-02-19 18:15
Modified
2024-11-21 05:17
Summary
The affected Fuji Electric V-Server Lite versions prior to 3.3.24.0 are vulnerable to an out-of-bounds write, which may allow an attacker to remotely execute arbitrary code.
References
ics-cert@hq.dhs.govhttps://us-cert.cisa.gov/ics/advisories/icsa-20-329-02Patch, Third Party Advisory, US Government Resource
af854a3a-2127-422b-91ae-364da2661108https://us-cert.cisa.gov/ics/advisories/icsa-20-329-02Patch, Third Party Advisory, US Government Resource
Impacted products
Vendor Product Version
fujielectric v-server *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "E95F89D4-C296-4CA1-988A-4528E4D94678",
              "versionEndExcluding": "3.3.24.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "The affected Fuji Electric V-Server Lite versions prior to 3.3.24.0 are vulnerable to an out-of-bounds write, which may allow an attacker to remotely execute arbitrary code."
    },
    {
      "lang": "es",
      "value": "Las versiones afectadas de Fuji Electric V-Server Lite anteriores a 3.3.24.0, son vulnerables a una escritura fuera de l\u00edmites, lo que puede permitir a un atacante ejecutar c\u00f3digo arbitrario remotamente"
    }
  ],
  "id": "CVE-2020-25171",
  "lastModified": "2024-11-21T05:17:32.623",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-02-19T18:15:11.377",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-329-02"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-329-02"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-12-20 21:15
Modified
2024-11-21 06:17
Summary
Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds read, which may allow an attacker to read sensitive information from other memory locations or cause a crash.
References
ics-cert@hq.dhs.govhttps://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01Patch, Third Party Advisory, US Government Resource
af854a3a-2127-422b-91ae-364da2661108https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01Patch, Third Party Advisory, US Government Resource
Impacted products
Vendor Product Version
fujielectric v-server *
fujielectric v-simulator *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "BDE5CC23-7376-4E69-988E-42719159E52C",
              "versionEndExcluding": "4.0.12.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fujielectric:v-simulator:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "1A6F4C85-64D7-4F4A-8652-5D4B6F8E6914",
              "versionEndExcluding": "4.0.12.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds read, which may allow an attacker to read sensitive information from other memory locations or cause a crash."
    },
    {
      "lang": "es",
      "value": "Fuji Electric V-Server Lite y Tellus Lite V-Simulator versiones anteriores a 4.0.12.0, son vulnerables a una lectura fuera de l\u00edmites, lo que puede permitir a un atacante leer informaci\u00f3n confidencial de otras ubicaciones de memoria o causar un bloqueo"
    }
  ],
  "id": "CVE-2021-38421",
  "lastModified": "2024-11-21T06:17:03.430",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 4.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.1,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.2,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-20T21:15:08.613",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-01-27 20:15
Modified
2024-11-21 05:50
Summary
An uninitialized pointer issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0).
Impacted products
Vendor Product Version
fujielectric v-server *
fujielectric v-simulator *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "3D8B4395-7ADA-4752-9DFF-B83E054596E4",
              "versionEndExcluding": "4.0.10.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fujielectric:v-simulator:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "B5EB143F-D650-45F2-9948-B1C2246E56A0",
              "versionEndExcluding": "4.0.10.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An uninitialized pointer issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0)."
    },
    {
      "lang": "es",
      "value": "Se ha identificado un problema de puntero no inicializado en la manera en que la aplicaci\u00f3n procesa archivos de proyecto, permitiendo a un atacante dise\u00f1ar un archivo de proyecto especial que puede permitir una ejecuci\u00f3n de c\u00f3digo arbitraria en el Tellus Lite V-Simulator y V-Server Lite (versiones anteriores a 4.0.10.0)"
    }
  ],
  "id": "CVE-2021-22639",
  "lastModified": "2024-11-21T05:50:21.947",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-01-27T20:15:12.847",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-098/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-098/"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-824"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-824"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-12-20 21:15
Modified
2024-11-21 06:17
Summary
Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable a heap-based buffer overflow when parsing a specially crafted project file, which may allow an attacker to execute arbitrary code.
References
ics-cert@hq.dhs.govhttps://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01Patch, Third Party Advisory, US Government Resource
af854a3a-2127-422b-91ae-364da2661108https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01Patch, Third Party Advisory, US Government Resource
Impacted products
Vendor Product Version
fujielectric v-server *
fujielectric v-simulator *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "BDE5CC23-7376-4E69-988E-42719159E52C",
              "versionEndExcluding": "4.0.12.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fujielectric:v-simulator:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "1A6F4C85-64D7-4F4A-8652-5D4B6F8E6914",
              "versionEndExcluding": "4.0.12.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable a heap-based buffer overflow when parsing a specially crafted project file, which may allow an attacker to execute arbitrary code."
    },
    {
      "lang": "es",
      "value": "Fuji Electric V-Server Lite y Tellus Lite V-Simulator versiones anteriores a 4.0.12.0, son vulnerables a un desbordamiento del b\u00fafer en la regi\u00f3n heap de la memoria cuando analizan un archivo de proyecto especialmente dise\u00f1ado, que puede permitir a un atacante ejecutar c\u00f3digo arbitrario"
    }
  ],
  "id": "CVE-2021-38415",
  "lastModified": "2024-11-21T06:17:02.447",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-20T21:15:08.500",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-122"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-01-03 03:15
Modified
2024-11-21 07:32
Summary
Stack-based buffer overflow vulnerability in V-Server v4.0.12.0 and earlier allows a local attacker to obtain the information and/or execute arbitrary code by having a user to open a specially crafted project file.
Impacted products
Vendor Product Version
fujielectric v-server *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "592FDE74-EB5F-4AD2-9F0B-5D021EB48C1E",
              "versionEndIncluding": "4.0.12.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Stack-based buffer overflow vulnerability in V-Server v4.0.12.0 and earlier allows a local attacker to obtain the information and/or execute arbitrary code by having a user to open a specially crafted project file."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de desbordamiento de b\u00fafer basada en pila en V-Server v4.0.12.0 y versiones anteriores permite que un atacante local obtenga la informaci\u00f3n y/o ejecute c\u00f3digo arbitrario haciendo que un usuario abra un archivo de proyecto especialmente manipulado."
    }
  ],
  "id": "CVE-2022-47908",
  "lastModified": "2024-11-21T07:32:30.883",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-01-03T03:15:10.990",
  "references": [
    {
      "source": "vultures@jpcert.or.jp",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://jvn.jp/en/vu/JVNVU92811888/index.html"
    },
    {
      "source": "vultures@jpcert.or.jp",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://jvn.jp/en/vu/JVNVU92811888/index.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php"
    }
  ],
  "sourceIdentifier": "vultures@jpcert.or.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-01-27 20:15
Modified
2024-11-21 05:50
Summary
Multiple stack-based buffer overflow issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0).
Impacted products
Vendor Product Version
fujielectric v-server *
fujielectric v-simulator *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "3D8B4395-7ADA-4752-9DFF-B83E054596E4",
              "versionEndExcluding": "4.0.10.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fujielectric:v-simulator:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "B5EB143F-D650-45F2-9948-B1C2246E56A0",
              "versionEndExcluding": "4.0.10.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Multiple stack-based buffer overflow issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0)."
    },
    {
      "lang": "es",
      "value": "Se han identificado m\u00faltiples problemas de desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria en la manera en que la aplicaci\u00f3n procesa archivos de proyecto, permitiendo a un atacante dise\u00f1ar un archivo de proyecto especial que puede permitir una ejecuci\u00f3n de c\u00f3digo arbitraria en el Tellus Lite V-Simulator y V-Server Lite (versiones anteriores a 4.0.10.0)"
    }
  ],
  "id": "CVE-2021-22637",
  "lastModified": "2024-11-21T05:50:21.713",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-01-27T20:15:12.770",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-097/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-097/"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-11-15 06:15
Modified
2024-11-21 08:30
Summary
Out-of-bounds read vulnerability exists in V-Server V4.0.18.0 and earlier and V-Server Lite V4.0.18.0 and earlier. If a user opens a specially crafted VPR file, information may be disclosed and/or arbitrary code may be executed.
Impacted products
Vendor Product Version
fujielectric v-server *
fujielectric v-server *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:-:*:*:*",
              "matchCriteriaId": "64415646-1087-4D64-B9D5-9BC3B46B8FA8",
              "versionEndIncluding": "4.0.18.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "6ABDE61D-26F7-4F70-90AE-E67A10DCA794",
              "versionEndIncluding": "4.0.18.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Out-of-bounds read vulnerability exists in V-Server V4.0.18.0 and earlier and V-Server Lite V4.0.18.0 and earlier. If a user opens a specially crafted VPR file, information may be disclosed and/or arbitrary code may be executed."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de lectura fuera de los l\u00edmites existe en V-Server V4.0.18.0 y anteriores y en V-Server Lite V4.0.18.0 y anteriores. Si un usuario abre un archivo VPR especialmente manipulado, se puede revelar informaci\u00f3n y/o se puede ejecutar c\u00f3digo arbitrario."
    }
  ],
  "id": "CVE-2023-47585",
  "lastModified": "2024-11-21T08:30:30.640",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-11-15T06:15:28.260",
  "references": [
    {
      "source": "vultures@jpcert.or.jp",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://hakko-elec.co.jp/site/download/03tellus_inf/index.php"
    },
    {
      "source": "vultures@jpcert.or.jp",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/en/vu/JVNVU93840158/"
    },
    {
      "source": "vultures@jpcert.or.jp",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://hakko-elec.co.jp/site/download/03tellus_inf/index.php"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/en/vu/JVNVU93840158/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php"
    }
  ],
  "sourceIdentifier": "vultures@jpcert.or.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-12-20 21:15
Modified
2024-11-21 06:17
Summary
Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an access of uninitialized pointer, which may allow an attacker read from or write to unexpected memory locations, leading to a denial-of-service.
References
ics-cert@hq.dhs.govhttps://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01Patch, Third Party Advisory, US Government Resource
af854a3a-2127-422b-91ae-364da2661108https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01Patch, Third Party Advisory, US Government Resource
Impacted products
Vendor Product Version
fujielectric v-server *
fujielectric v-simulator *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "BDE5CC23-7376-4E69-988E-42719159E52C",
              "versionEndExcluding": "4.0.12.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fujielectric:v-simulator:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "1A6F4C85-64D7-4F4A-8652-5D4B6F8E6914",
              "versionEndExcluding": "4.0.12.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an access of uninitialized pointer, which may allow an attacker read from or write to unexpected memory locations, leading to a denial-of-service."
    },
    {
      "lang": "es",
      "value": "Fuji Electric V-Server Lite y Tellus Lite V-Simulator versiones anteriores a 4.0.12.0, son vulnerables a un acceso de puntero no inicializado, que puede permitir a un atacante leer o escribir en ubicaciones de memoria no esperadas, conllevando a una denegaci\u00f3n de servicio"
    }
  ],
  "id": "CVE-2021-38409",
  "lastModified": "2024-11-21T06:17:01.630",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-20T21:15:08.383",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-824"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2020-04-13 19:15
Modified
2024-11-21 04:55
Summary
Fuji Electric V-Server Lite all versions prior to 4.0.9.0 contains a heap based buffer overflow. The buffer allocated to read data, when parsing VPR files, is too small.
References
Impacted products
Vendor Product Version
fujielectric v-server *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "76726204-8145-4477-B1E1-8A42019F541E",
              "versionEndExcluding": "4.0.9.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Fuji Electric V-Server Lite all versions prior to 4.0.9.0 contains a heap based buffer overflow. The buffer allocated to read data, when parsing VPR files, is too small."
    },
    {
      "lang": "es",
      "value": "Fuji Electric V-Server Lite todas las  versiones anteriores a 4.0.9.0, contiene un desbordamiento de b\u00fafer en la regi\u00f3n heap de la memoria. El b\u00fafer asignado para leer datos, cuando se analizan archivos VPR, es muy peque\u00f1o."
    }
  ],
  "id": "CVE-2020-10646",
  "lastModified": "2024-11-21T04:55:45.903",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2020-04-13T19:15:11.047",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.us-cert.gov/ics/advisories/icsa-20-098-04"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.us-cert.gov/ics/advisories/icsa-20-098-04"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-122"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-01-27 20:15
Modified
2024-11-21 05:50
Summary
Multiple out-of-bounds read issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0).
References
Impacted products
Vendor Product Version
fujielectric v-server *
fujielectric v-simulator *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "3D8B4395-7ADA-4752-9DFF-B83E054596E4",
              "versionEndExcluding": "4.0.10.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fujielectric:v-simulator:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "B5EB143F-D650-45F2-9948-B1C2246E56A0",
              "versionEndExcluding": "4.0.10.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Multiple out-of-bounds read issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0)."
    },
    {
      "lang": "es",
      "value": "Se han identificado m\u00faltiples problemas de lectura fuera de l\u00edmites en la manera en que la aplicaci\u00f3n procesa archivos de proyecto, permitiendo a un atacante dise\u00f1ar un archivo de proyecto especial que puede permitir una ejecuci\u00f3n de c\u00f3digo arbitraria en el Tellus Lite V-Simulator y V-Server Lite (versiones anteriores a 4.0.10.0)"
    }
  ],
  "id": "CVE-2021-22655",
  "lastModified": "2024-11-21T05:50:24.890",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-01-27T20:15:13.397",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2018-09-26 20:29
Modified
2024-11-21 03:49
Severity ?
Summary
Fuji Electric V-Server 4.0.3.0 and prior, An integer underflow vulnerability has been identified, which may allow remote code execution.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:fujielectric:v-server_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "09EDDB15-323C-4ED5-8288-5297D7396F09",
              "versionEndIncluding": "4.0.3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:fujielectric:v-server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "10FE5445-2A67-4B12-8A38-B960E6002340",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Fuji Electric V-Server 4.0.3.0 and prior, An integer underflow vulnerability has been identified, which may allow remote code execution."
    },
    {
      "lang": "es",
      "value": "En Fuji Electric V-Server en versiones 4.0.3.0 y anteriores, se ha identificado una vulnerabilidad de subdesbordamiento de enteros que podr\u00eda permitir la ejecuci\u00f3n remota de c\u00f3digo."
    }
  ],
  "id": "CVE-2018-14817",
  "lastModified": "2024-11-21T03:49:51.510",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-09-26T20:29:00.747",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/105341"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/105341"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-191"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-191"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2018-09-26 20:29
Modified
2024-11-21 03:49
Severity ?
Summary
Fuji Electric V-Server 4.0.3.0 and prior, A use after free vulnerability has been identified, which may allow remote code execution.
References
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:fujielectric:v-server_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "09EDDB15-323C-4ED5-8288-5297D7396F09",
              "versionEndIncluding": "4.0.3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:fujielectric:v-server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "10FE5445-2A67-4B12-8A38-B960E6002340",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Fuji Electric V-Server 4.0.3.0 and prior, A use after free vulnerability has been identified, which may allow remote code execution."
    },
    {
      "lang": "es",
      "value": "En Fuji Electric V-Server en versiones 4.0.3.0 y anteriores, se ha identificado una vulnerabilidad de uso de memoria previamente liberada que podr\u00eda permitir la ejecuci\u00f3n remota de c\u00f3digo."
    }
  ],
  "id": "CVE-2018-14809",
  "lastModified": "2024-11-21T03:49:50.547",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-09-26T20:29:00.293",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-416"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-416"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-11-15 06:15
Modified
2024-11-21 08:30
Summary
Multiple heap-based buffer overflow vulnerabilities exist in V-Server V4.0.18.0 and earlier and V-Server Lite V4.0.18.0 and earlier. If a user opens a specially crafted VPR file, information may be disclosed and/or arbitrary code may be executed.
Impacted products
Vendor Product Version
fujielectric v-server *
fujielectric v-server *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:-:*:*:*",
              "matchCriteriaId": "64415646-1087-4D64-B9D5-9BC3B46B8FA8",
              "versionEndIncluding": "4.0.18.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "6ABDE61D-26F7-4F70-90AE-E67A10DCA794",
              "versionEndIncluding": "4.0.18.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Multiple heap-based buffer overflow vulnerabilities exist in V-Server V4.0.18.0 and earlier and V-Server Lite V4.0.18.0 and earlier. If a user opens a specially crafted VPR file, information may be disclosed and/or arbitrary code may be executed."
    },
    {
      "lang": "es",
      "value": "Existen m\u00faltiples vulnerabilidades de desbordamiento del b\u00fafer en V-Server V4.0.18.0 y anteriores y V-Server Lite V4.0.18.0 y anteriores. Si un usuario abre un archivo VPR especialmente manipulado, se puede revelar informaci\u00f3n y/o se puede ejecutar c\u00f3digo arbitrario."
    }
  ],
  "id": "CVE-2023-47586",
  "lastModified": "2024-11-21T08:30:30.777",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-11-15T06:15:28.303",
  "references": [
    {
      "source": "vultures@jpcert.or.jp",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://hakko-elec.co.jp/site/download/03tellus_inf/index.php"
    },
    {
      "source": "vultures@jpcert.or.jp",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/en/vu/JVNVU93840158/"
    },
    {
      "source": "vultures@jpcert.or.jp",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://hakko-elec.co.jp/site/download/03tellus_inf/index.php"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/en/vu/JVNVU93840158/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php"
    }
  ],
  "sourceIdentifier": "vultures@jpcert.or.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-01-27 20:15
Modified
2024-11-21 05:50
Summary
Multiple out-of-bounds write issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0).
References
Impacted products
Vendor Product Version
fujielectric v-server *
fujielectric v-simulator *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "3D8B4395-7ADA-4752-9DFF-B83E054596E4",
              "versionEndExcluding": "4.0.10.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fujielectric:v-simulator:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "B5EB143F-D650-45F2-9948-B1C2246E56A0",
              "versionEndExcluding": "4.0.10.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Multiple out-of-bounds write issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0)."
    },
    {
      "lang": "es",
      "value": "Se han identificado m\u00faltiples problemas de escritura fuera de l\u00edmites en la manera en que la aplicaci\u00f3n procesa archivos de proyecto, permitiendo a un atacante dise\u00f1ar un archivo de proyecto especial que puede permitir una ejecuci\u00f3n de c\u00f3digo arbitraria en el Tellus Lite V-Simulator y V-Server Lite (versiones anteriores a 4.0.10.0)"
    }
  ],
  "id": "CVE-2021-22653",
  "lastModified": "2024-11-21T05:50:24.550",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-01-27T20:15:13.317",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2019-06-12 15:29
Modified
2024-11-21 04:42
Severity ?
Summary
Fuji Electric V-Server before 6.0.33.0 stores database credentials in project files as plaintext. An attacker that can gain access to the project file can recover the database credentials and gain access to the database server.
Impacted products
Vendor Product Version
fujielectric v-server *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F47D918A-C673-47E3-8C59-64F116247C25",
              "versionEndExcluding": "6.0.33.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Fuji Electric V-Server before 6.0.33.0 stores database credentials in project files as plaintext. An attacker that can gain access to the project file can recover the database credentials and gain access to the database server."
    },
    {
      "lang": "es",
      "value": "Fuji Electric V-Server anterior 6.0.33.0 almacena credenciales en archivos de proyecto como plaintext un atacante que puede obtener accesos para los archivos de proyecto puede recuperar las credenciales de bases de datos y conseguir acceso a la base de datos del servidor"
    }
  ],
  "id": "CVE-2019-3947",
  "lastModified": "2024-11-21T04:42:55.407",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-06-12T15:29:00.910",
  "references": [
    {
      "source": "vulnreport@tenable.com",
      "url": "http://www.securityfocus.com/bid/108740"
    },
    {
      "source": "vulnreport@tenable.com",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://www.tenable.com/security/research/tra-2019-27"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.securityfocus.com/bid/108740"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://www.tenable.com/security/research/tra-2019-27"
    }
  ],
  "sourceIdentifier": "vulnreport@tenable.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-522"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-12-20 21:15
Modified
2024-11-21 06:17
Summary
Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds write, which can result in data corruption, a system crash, or code execution.
References
ics-cert@hq.dhs.govhttps://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01Patch, Third Party Advisory, US Government Resource
af854a3a-2127-422b-91ae-364da2661108https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01Patch, Third Party Advisory, US Government Resource
Impacted products
Vendor Product Version
fujielectric v-server *
fujielectric v-simulator *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "BDE5CC23-7376-4E69-988E-42719159E52C",
              "versionEndExcluding": "4.0.12.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fujielectric:v-simulator:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "1A6F4C85-64D7-4F4A-8652-5D4B6F8E6914",
              "versionEndExcluding": "4.0.12.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds write, which can result in data corruption, a system crash, or code execution."
    },
    {
      "lang": "es",
      "value": "Fuji Electric V-Server Lite y Tellus Lite V-Simulator versiones anteriores a 4.0.12.0, son vulnerables a una escritura fuera de l\u00edmites, que puede resultar en una corrupci\u00f3n de datos, a un bloqueo del sistema o a una ejecuci\u00f3n de c\u00f3digo"
    }
  ],
  "id": "CVE-2021-38419",
  "lastModified": "2024-11-21T06:17:03.123",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-20T21:15:08.557",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-12-20 21:15
Modified
2024-11-21 06:17
Summary
Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to a stack-based buffer overflow, which may allow an attacker to achieve code execution.
References
ics-cert@hq.dhs.govhttps://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01Patch, Third Party Advisory, US Government Resource
af854a3a-2127-422b-91ae-364da2661108https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01Patch, Third Party Advisory, US Government Resource
Impacted products
Vendor Product Version
fujielectric v-server *
fujielectric v-simulator *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "BDE5CC23-7376-4E69-988E-42719159E52C",
              "versionEndExcluding": "4.0.12.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fujielectric:v-simulator:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "1A6F4C85-64D7-4F4A-8652-5D4B6F8E6914",
              "versionEndExcluding": "4.0.12.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to a stack-based buffer overflow, which may allow an attacker to achieve code execution."
    },
    {
      "lang": "es",
      "value": "Fuji Electric V-Server Lite y Tellus Lite V-Simulator versiones anteriores a 4.0.12.0, son vulnerables a un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria, que puede permitir a un atacante una ejecuci\u00f3n de c\u00f3digo"
    }
  ],
  "id": "CVE-2021-38413",
  "lastModified": "2024-11-21T06:17:02.293",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-20T21:15:08.440",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2018-09-26 20:29
Modified
2024-11-21 03:49
Severity ?
Summary
Fuji Electric V-Server 4.0.3.0 and prior, Multiple untrusted pointer dereference vulnerabilities have been identified, which may allow remote code execution.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:fujielectric:v-server_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "09EDDB15-323C-4ED5-8288-5297D7396F09",
              "versionEndIncluding": "4.0.3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:fujielectric:v-server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "10FE5445-2A67-4B12-8A38-B960E6002340",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Fuji Electric V-Server 4.0.3.0 and prior, Multiple untrusted pointer dereference vulnerabilities have been identified, which may allow remote code execution."
    },
    {
      "lang": "es",
      "value": "En Fuji Electric V-Server en versiones 4.0.3.0 y anteriores, se han identificado m\u00faltiples vulnerabilidades de desreferencia de puntero no fiable que podr\u00edan permitir la ejecuci\u00f3n remota de c\u00f3digo."
    }
  ],
  "id": "CVE-2018-14811",
  "lastModified": "2024-11-21T03:49:50.773",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-09-26T20:29:00.403",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/105341"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/105341"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-822"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-476"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2019-06-12 15:29
Modified
2024-11-21 04:42
Summary
Fuji Electric V-Server before 6.0.33.0 is vulnerable to denial of service via a crafted UDP message sent to port 8005. An unauthenticated, remote attacker can crash vserver.exe due to an integer overflow in the UDP message handling logic.
Impacted products
Vendor Product Version
fujielectric v-server *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F47D918A-C673-47E3-8C59-64F116247C25",
              "versionEndExcluding": "6.0.33.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Fuji Electric V-Server before 6.0.33.0 is vulnerable to denial of service via a crafted UDP message sent to port 8005. An unauthenticated, remote attacker can crash vserver.exe due to an integer overflow in the UDP message handling logic."
    },
    {
      "lang": "es",
      "value": "El Fuji Electric V-Server anterior a versi\u00f3n 6.0.33.0, es vulnerable a la denegaci\u00f3n de servicio por medio de un mensaje UDP creado en el puerto 8005. Un atacante remoto no identificado puede bloquear el archivo vserver.exe debido a un desbordamiento de enteros en la l\u00f3gica de manejo de mensajes UDP."
    }
  ],
  "id": "CVE-2019-3946",
  "lastModified": "2024-11-21T04:42:55.280",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.0,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-06-12T15:29:00.863",
  "references": [
    {
      "source": "vulnreport@tenable.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "http://www.securityfocus.com/bid/108740"
    },
    {
      "source": "vulnreport@tenable.com",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://www.tenable.com/security/research/tra-2019-27"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "http://www.securityfocus.com/bid/108740"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://www.tenable.com/security/research/tra-2019-27"
    }
  ],
  "sourceIdentifier": "vulnreport@tenable.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-190"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2018-09-26 20:29
Modified
2024-11-21 03:49
Severity ?
Summary
Fuji Electric V-Server 4.0.3.0 and prior, A heap-based buffer overflow vulnerability has been identified, which may allow remote code execution.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:fujielectric:v-server_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "09EDDB15-323C-4ED5-8288-5297D7396F09",
              "versionEndIncluding": "4.0.3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:fujielectric:v-server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "10FE5445-2A67-4B12-8A38-B960E6002340",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Fuji Electric V-Server 4.0.3.0 and prior, A heap-based buffer overflow vulnerability has been identified, which may allow remote code execution."
    },
    {
      "lang": "es",
      "value": "En Fuji Electric V-Server en versiones 4.0.3.0 y anteriores, se ha identificado una vulnerabilidad de desbordamiento de b\u00fafer basado en memoria din\u00e1mica (heap) que podr\u00eda permitir la ejecuci\u00f3n remota de c\u00f3digo."
    }
  ],
  "id": "CVE-2018-14813",
  "lastModified": "2024-11-21T03:49:50.993",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-09-26T20:29:00.510",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/105341"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/105341"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-122"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-12-20 21:15
Modified
2024-11-21 06:17
Summary
Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an untrusted pointer dereference, which may allow an attacker to execute arbitrary code and cause the application to crash.
References
ics-cert@hq.dhs.govhttps://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01Patch, Third Party Advisory, US Government Resource
af854a3a-2127-422b-91ae-364da2661108https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01Patch, Third Party Advisory, US Government Resource
Impacted products
Vendor Product Version
fujielectric v-server *
fujielectric v-simulator *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "BDE5CC23-7376-4E69-988E-42719159E52C",
              "versionEndExcluding": "4.0.12.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fujielectric:v-simulator:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "1A6F4C85-64D7-4F4A-8652-5D4B6F8E6914",
              "versionEndExcluding": "4.0.12.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an untrusted pointer dereference, which may allow an attacker to execute arbitrary code and cause the application to crash."
    },
    {
      "lang": "es",
      "value": "Fuji Electric V-Server Lite y Tellus Lite V-Simulator versiones anteriores a 4.0.12.0, son vulnerables a un acceso de puntero no inicializado, que puede permitir a un atacante ejecutar c\u00f3digo arbitrario y causar un bloqueo de la aplicaci\u00f3n"
    }
  ],
  "id": "CVE-2021-38401",
  "lastModified": "2024-11-21T06:17:00.403",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-20T21:15:08.320",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-822"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Primary"
    }
  ]
}

var-201809-0150
Vulnerability from variot

Fuji Electric V-Server 4.0.3.0 and prior, A use after free vulnerability has been identified, which may allow remote code execution. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of a VPR file. The issue results from the lack of validating the existence of an object prior to performing operations on the object. An attacker can leverage this vulnerability to execute code under the context of the process. Fuji Electric V-Server VPR is a data collection software from Fuji Electric of Japan

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201809-0150",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "v-server",
        "scope": null,
        "trust": 1.4,
        "vendor": "fuji electric",
        "version": null
      },
      {
        "model": "v-server",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "4.0.3.0"
      },
      {
        "model": "v-server",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "fuji electric",
        "version": "4.0.3.0"
      },
      {
        "model": "electric v-server vpr",
        "scope": "lte",
        "trust": 0.6,
        "vendor": "fuji",
        "version": "\u003c=4.0.3.0"
      },
      {
        "model": "v-server",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "fujielectric",
        "version": "4.0.3.0"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "v server",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d85b770-463f-11e9-a599-000c29342cb1"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1019"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1010"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-19868"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010413"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-576"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14809"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:fujielectric:v-server",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010413"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Steven Seeley (mr_me) of Source Incite",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-18-1019"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1010"
      }
    ],
    "trust": 1.4
  },
  "cve": "CVE-2018-14809",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-14809",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "ZDI",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CVE-2018-14809",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "MEDIUM",
            "trust": 1.4,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2018-19868",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "7d85b770-463f-11e9-a599-000c29342cb1",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "VHN-125005",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-14809",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "ZDI",
            "id": "CVE-2018-14809",
            "trust": 1.4,
            "value": "MEDIUM"
          },
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-14809",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-14809",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2018-19868",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201809-576",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "IVD",
            "id": "7d85b770-463f-11e9-a599-000c29342cb1",
            "trust": 0.2,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-125005",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d85b770-463f-11e9-a599-000c29342cb1"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1019"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1010"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-19868"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125005"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010413"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-576"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14809"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Fuji Electric V-Server 4.0.3.0 and prior, A use after free vulnerability has been identified, which may allow remote code execution.  User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of a VPR file. The issue results from the lack of validating the existence of an object prior to performing operations on the object. An attacker can leverage this vulnerability to execute code under the context of the process. Fuji Electric V-Server VPR is a data collection software from Fuji Electric of Japan",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-14809"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010413"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1019"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1010"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-19868"
      },
      {
        "db": "IVD",
        "id": "7d85b770-463f-11e9-a599-000c29342cb1"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125005"
      }
    ],
    "trust": 3.69
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-14809",
        "trust": 4.7
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-18-254-01",
        "trust": 2.5
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-576",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-19868",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010413",
        "trust": 0.8
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-5885",
        "trust": 0.7
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1019",
        "trust": 0.7
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-5877",
        "trust": 0.7
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1010",
        "trust": 0.7
      },
      {
        "db": "IVD",
        "id": "7D85B770-463F-11E9-A599-000C29342CB1",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-125005",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d85b770-463f-11e9-a599-000c29342cb1"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1019"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1010"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-19868"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125005"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010413"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-576"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14809"
      }
    ]
  },
  "id": "VAR-201809-0150",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "7d85b770-463f-11e9-a599-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-19868"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125005"
      }
    ],
    "trust": 1.77058824
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d85b770-463f-11e9-a599-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-19868"
      }
    ]
  },
  "last_update_date": "2024-11-23T21:38:24.046000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Fuji Electric has issued an update to correct this vulnerability.",
        "trust": 1.4,
        "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
      },
      {
        "title": "\u30c8\u30c3\u30d7\u30da\u30fc\u30b8",
        "trust": 0.8,
        "url": "https://www.fujielectric.co.jp/"
      },
      {
        "title": "Fuji Electric V-Server VPR Memory Error Reference Vulnerability Patch",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/141099"
      },
      {
        "title": "Fuji Electric V-Server VPR Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=84843"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-18-1019"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1010"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-19868"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010413"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-576"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-416",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-125005"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010413"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14809"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.9,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-254-01"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-14809"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14809"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-18-1019"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1010"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-19868"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125005"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010413"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-576"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14809"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "7d85b770-463f-11e9-a599-000c29342cb1"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1019"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1010"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-19868"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125005"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010413"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-576"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14809"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-09-27T00:00:00",
        "db": "IVD",
        "id": "7d85b770-463f-11e9-a599-000c29342cb1"
      },
      {
        "date": "2018-09-12T00:00:00",
        "db": "ZDI",
        "id": "ZDI-18-1019"
      },
      {
        "date": "2018-09-12T00:00:00",
        "db": "ZDI",
        "id": "ZDI-18-1010"
      },
      {
        "date": "2018-09-27T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-19868"
      },
      {
        "date": "2018-09-26T00:00:00",
        "db": "VULHUB",
        "id": "VHN-125005"
      },
      {
        "date": "2018-12-13T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-010413"
      },
      {
        "date": "2018-09-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201809-576"
      },
      {
        "date": "2018-09-26T20:29:00.293000",
        "db": "NVD",
        "id": "CVE-2018-14809"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-09-12T00:00:00",
        "db": "ZDI",
        "id": "ZDI-18-1019"
      },
      {
        "date": "2018-09-12T00:00:00",
        "db": "ZDI",
        "id": "ZDI-18-1010"
      },
      {
        "date": "2019-01-23T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-19868"
      },
      {
        "date": "2019-10-09T00:00:00",
        "db": "VULHUB",
        "id": "VHN-125005"
      },
      {
        "date": "2018-12-13T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-010413"
      },
      {
        "date": "2019-10-17T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201809-576"
      },
      {
        "date": "2024-11-21T03:49:50.547000",
        "db": "NVD",
        "id": "CVE-2018-14809"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-576"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Fuji Electric V-Server VPR Memory Error Reference Vulnerability",
    "sources": [
      {
        "db": "IVD",
        "id": "7d85b770-463f-11e9-a599-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-19868"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Resource management error",
    "sources": [
      {
        "db": "IVD",
        "id": "7d85b770-463f-11e9-a599-000c29342cb1"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-576"
      }
    ],
    "trust": 0.8
  }
}

var-201809-0083
Vulnerability from variot

A maliciously crafted project file may cause a buffer overflow, which may allow the attacker to execute arbitrary code that affects Fuji Electric V-Server Lite 4.0.3.0 and prior. Fuji Electric V-Server Lite Contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the processing of VPR files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a buffer. An attacker can leverage this vulnerability to execute arbitrary code in the context of the current process. Failed exploit attempts will likely cause a denial-of-service condition. V-Server Lite 4.0.3.0 and prior versions are vulnerable

Show details on source website


{
  "affected_products": {
    "_id": null,
    "data": [
      {
        "_id": null,
        "model": "v-server",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "4.0.3.0"
      },
      {
        "_id": null,
        "model": "v-server",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "fuji electric",
        "version": "lite 4.0.3.0"
      },
      {
        "_id": null,
        "model": "v-server lite",
        "scope": null,
        "trust": 0.7,
        "vendor": "fuji electric",
        "version": null
      },
      {
        "_id": null,
        "model": "v-server",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "fujielectric",
        "version": "4.0.3.0"
      },
      {
        "_id": null,
        "model": "electric v-server lite",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "4.0.3.0"
      },
      {
        "_id": null,
        "model": "electric v-server lite",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "4.0.0.0"
      },
      {
        "_id": null,
        "model": "electric v-server lite",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "3.3.22.0"
      },
      {
        "_id": null,
        "model": "electric v-server lite",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "3.0.1.0"
      },
      {
        "_id": null,
        "model": "electric v-server lite",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "2.1.36.0"
      },
      {
        "_id": null,
        "model": "electric v-server lite",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "2.0.0.0"
      },
      {
        "_id": null,
        "model": "electric v-server lite",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "4.0.4.0"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-18-1023"
      },
      {
        "db": "BID",
        "id": "105328"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010848"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-575"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-10637"
      }
    ]
  },
  "configurations": {
    "_id": null,
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:fujielectric:v-server",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010848"
      }
    ]
  },
  "credits": {
    "_id": null,
    "data": "Ariele Caltabiano (kimiya)",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-18-1023"
      }
    ],
    "trust": 0.7
  },
  "cve": "CVE-2018-10637",
  "cvss": {
    "_id": null,
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CVE-2018-10637",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "ZDI",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.6,
            "id": "CVE-2018-10637",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "HIGH",
            "trust": 0.7,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2018-10637",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-10637",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-10637",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "ZDI",
            "id": "CVE-2018-10637",
            "trust": 0.7,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201809-575",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-18-1023"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010848"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-575"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-10637"
      }
    ]
  },
  "description": {
    "_id": null,
    "data": "A maliciously crafted project file may cause a buffer overflow, which may allow the attacker to execute arbitrary code that affects Fuji Electric V-Server Lite 4.0.3.0 and prior. Fuji Electric V-Server Lite Contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the processing of VPR files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a buffer. An attacker can leverage this vulnerability to execute arbitrary code in the context of the current process. Failed exploit attempts will likely cause a denial-of-service condition. \nV-Server Lite 4.0.3.0 and prior versions are vulnerable",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-10637"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010848"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1023"
      },
      {
        "db": "BID",
        "id": "105328"
      }
    ],
    "trust": 2.52
  },
  "external_ids": {
    "_id": null,
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-10637",
        "trust": 3.4
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-18-254-02",
        "trust": 2.7
      },
      {
        "db": "BID",
        "id": "105328",
        "trust": 1.9
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010848",
        "trust": 0.8
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-6376",
        "trust": 0.7
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1023",
        "trust": 0.7
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-575",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-18-1023"
      },
      {
        "db": "BID",
        "id": "105328"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010848"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-575"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-10637"
      }
    ]
  },
  "id": "VAR-201809-0083",
  "iot": {
    "_id": null,
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.87058824
  },
  "last_update_date": "2024-11-23T22:26:14.101000Z",
  "patch": {
    "_id": null,
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.fujielectric.co.jp/"
      },
      {
        "title": "Fuji Electric has issued an update to correct this vulnerability.",
        "trust": 0.7,
        "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-02"
      },
      {
        "title": "Fuji Electric V-Server Lite Buffer error vulnerability fix",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=84842"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-18-1023"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010848"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-575"
      }
    ]
  },
  "problemtype_data": {
    "_id": null,
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.8
      },
      {
        "problemtype": "CWE-120",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010848"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-10637"
      }
    ]
  },
  "references": {
    "_id": null,
    "data": [
      {
        "trust": 3.4,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-254-02"
      },
      {
        "trust": 1.6,
        "url": "http://www.securityfocus.com/bid/105328"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-10637"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-10637"
      },
      {
        "trust": 0.3,
        "url": "http://www.fujielectric.com/"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-18-1023"
      },
      {
        "db": "BID",
        "id": "105328"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010848"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-575"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-10637"
      }
    ]
  },
  "sources": {
    "_id": null,
    "data": [
      {
        "db": "ZDI",
        "id": "ZDI-18-1023",
        "ident": null
      },
      {
        "db": "BID",
        "id": "105328",
        "ident": null
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010848",
        "ident": null
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-575",
        "ident": null
      },
      {
        "db": "NVD",
        "id": "CVE-2018-10637",
        "ident": null
      }
    ]
  },
  "sources_release_date": {
    "_id": null,
    "data": [
      {
        "date": "2018-09-12T00:00:00",
        "db": "ZDI",
        "id": "ZDI-18-1023",
        "ident": null
      },
      {
        "date": "2018-09-11T00:00:00",
        "db": "BID",
        "id": "105328",
        "ident": null
      },
      {
        "date": "2018-12-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-010848",
        "ident": null
      },
      {
        "date": "2018-09-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201809-575",
        "ident": null
      },
      {
        "date": "2018-09-13T19:29:00.277000",
        "db": "NVD",
        "id": "CVE-2018-10637",
        "ident": null
      }
    ]
  },
  "sources_update_date": {
    "_id": null,
    "data": [
      {
        "date": "2018-09-12T00:00:00",
        "db": "ZDI",
        "id": "ZDI-18-1023",
        "ident": null
      },
      {
        "date": "2018-09-11T00:00:00",
        "db": "BID",
        "id": "105328",
        "ident": null
      },
      {
        "date": "2018-12-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-010848",
        "ident": null
      },
      {
        "date": "2019-10-17T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201809-575",
        "ident": null
      },
      {
        "date": "2024-11-21T03:41:42.753000",
        "db": "NVD",
        "id": "CVE-2018-10637",
        "ident": null
      }
    ]
  },
  "threat_type": {
    "_id": null,
    "data": "local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-575"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "_id": null,
    "data": "Fuji Electric V-Server Lite Buffer error vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010848"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-575"
      }
    ],
    "trust": 1.4
  },
  "type": {
    "_id": null,
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-575"
      }
    ],
    "trust": 0.6
  }
}

var-201809-0151
Vulnerability from variot

Fuji Electric V-Server 4.0.3.0 and prior, Multiple untrusted pointer dereference vulnerabilities have been identified, which may allow remote code execution. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of a VPR file. The issue results from the lack of proper validation of a user-supplied value prior to dereferencing it as a pointer. An attacker can leverage this vulnerability to execute code under the context of the process. Fuji Electric V-Server VPR is a data collection software from Fuji Electric of Japan. Fuji Electric V-Server is prone to multiple security vulnerabilities: 1. A use-after-free vulnerability 2. A heap-based buffer overflow vulnerability 4. Multiple out-of-bounds write vulnerabilities 5. An integer underflow vulnerability 6. An out-of-bounds read vulnerability 7. V-Server 4.0.3.0 and prior are vulnerable

Show details on source website


{
  "affected_products": {
    "_id": null,
    "data": [
      {
        "_id": null,
        "model": "v-server",
        "scope": null,
        "trust": 3.5,
        "vendor": "fuji electric",
        "version": null
      },
      {
        "_id": null,
        "model": "v-server",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "4.0.3.0"
      },
      {
        "_id": null,
        "model": "v-server",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "fuji electric",
        "version": "4.0.3.0"
      },
      {
        "_id": null,
        "model": "electric v-server vpr",
        "scope": "lte",
        "trust": 0.6,
        "vendor": "fuji",
        "version": "\u003c=4.0.3.0"
      },
      {
        "_id": null,
        "model": "v-server",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "fujielectric",
        "version": "4.0.3.0"
      },
      {
        "_id": null,
        "model": "electric v-server",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "4.0.3.0"
      },
      {
        "_id": null,
        "model": "electric v-server",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "4.0.1.0"
      },
      {
        "_id": null,
        "model": "electric v-server",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "4.0.0.0"
      },
      {
        "_id": null,
        "model": "electric v-server",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "3.3.22.0"
      },
      {
        "_id": null,
        "model": "electric v-server",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "4.0.4.0"
      },
      {
        "_id": null,
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "v server",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d85de80-463f-11e9-8522-000c29342cb1"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1014"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1011"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1020"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1022"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1021"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-03306"
      },
      {
        "db": "BID",
        "id": "105341"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010414"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-577"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14811"
      }
    ]
  },
  "configurations": {
    "_id": null,
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:fujielectric:v-server",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010414"
      }
    ]
  },
  "credits": {
    "_id": null,
    "data": "Steven Seeley (mr_me) of Source Incite",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-18-1014"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1011"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1020"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1022"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1021"
      }
    ],
    "trust": 3.5
  },
  "cve": "CVE-2018-14811",
  "cvss": {
    "_id": null,
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": null,
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "ZDI",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CVE-2018-14811",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "MEDIUM",
            "trust": 3.5,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-14811",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-03306",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "7d85de80-463f-11e9-8522-000c29342cb1",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "VHN-125008",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-14811",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "ZDI",
            "id": "CVE-2018-14811",
            "trust": 3.5,
            "value": "MEDIUM"
          },
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-14811",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-14811",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-03306",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201809-577",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "IVD",
            "id": "7d85de80-463f-11e9-8522-000c29342cb1",
            "trust": 0.2,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-125008",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d85de80-463f-11e9-8522-000c29342cb1"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1014"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1011"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1020"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1022"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1021"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-03306"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125008"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010414"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-577"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14811"
      }
    ]
  },
  "description": {
    "_id": null,
    "data": "Fuji Electric V-Server 4.0.3.0 and prior, Multiple untrusted pointer dereference vulnerabilities have been identified, which may allow remote code execution. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of a VPR file. The issue results from the lack of proper validation of a user-supplied value prior to dereferencing it as a pointer.  An attacker can leverage this vulnerability to execute code under the context of the process. Fuji Electric V-Server VPR is a data collection software from Fuji Electric of Japan. Fuji Electric V-Server is prone to multiple security vulnerabilities:\n1. A use-after-free vulnerability\n2. A heap-based buffer overflow vulnerability\n4. Multiple out-of-bounds write vulnerabilities\n5. An integer underflow vulnerability\n6. An out-of-bounds read vulnerability\n7. \nV-Server 4.0.3.0 and prior are vulnerable",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-14811"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010414"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1014"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1011"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1020"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1022"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1021"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-03306"
      },
      {
        "db": "BID",
        "id": "105341"
      },
      {
        "db": "IVD",
        "id": "7d85de80-463f-11e9-8522-000c29342cb1"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125008"
      }
    ],
    "trust": 5.85
  },
  "external_ids": {
    "_id": null,
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-14811",
        "trust": 7.1
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-18-254-01",
        "trust": 2.8
      },
      {
        "db": "BID",
        "id": "105341",
        "trust": 2.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-577",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-03306",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010414",
        "trust": 0.8
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-5880",
        "trust": 0.7
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1014",
        "trust": 0.7
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-5878",
        "trust": 0.7
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1011",
        "trust": 0.7
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-5886",
        "trust": 0.7
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1020",
        "trust": 0.7
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-5888",
        "trust": 0.7
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1022",
        "trust": 0.7
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-5887",
        "trust": 0.7
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1021",
        "trust": 0.7
      },
      {
        "db": "IVD",
        "id": "7D85DE80-463F-11E9-8522-000C29342CB1",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-125008",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d85de80-463f-11e9-8522-000c29342cb1"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1014"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1011"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1020"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1022"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1021"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-03306"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125008"
      },
      {
        "db": "BID",
        "id": "105341"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010414"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-577"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14811"
      }
    ]
  },
  "id": "VAR-201809-0151",
  "iot": {
    "_id": null,
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "7d85de80-463f-11e9-8522-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-03306"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125008"
      }
    ],
    "trust": 1.77058824
  },
  "iot_taxonomy": {
    "_id": null,
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d85de80-463f-11e9-8522-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-03306"
      }
    ]
  },
  "last_update_date": "2024-11-23T21:38:23.937000Z",
  "patch": {
    "_id": null,
    "data": [
      {
        "title": "Fuji Electric has issued an update to correct this vulnerability.",
        "trust": 3.5,
        "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
      },
      {
        "title": "\u30c8\u30c3\u30d7\u30da\u30fc\u30b8",
        "trust": 0.8,
        "url": "https://www.fujielectric.co.jp/"
      },
      {
        "title": "Fuji Electric V-Server releases patches for reusing vulnerabilities",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/152185"
      },
      {
        "title": "Fuji Electric V-Server VPR Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=84844"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-18-1014"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1011"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1020"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1022"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1021"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-03306"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010414"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-577"
      }
    ]
  },
  "problemtype_data": {
    "_id": null,
    "data": [
      {
        "problemtype": "CWE-476",
        "trust": 1.9
      },
      {
        "problemtype": "CWE-822",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-125008"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010414"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14811"
      }
    ]
  },
  "references": {
    "_id": null,
    "data": [
      {
        "trust": 6.3,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-254-01"
      },
      {
        "trust": 2.3,
        "url": "http://www.securityfocus.com/bid/105341"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14811"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-14811"
      },
      {
        "trust": 0.3,
        "url": "http://www.fujielectric.com/"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-18-1014"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1011"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1020"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1022"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1021"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-03306"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125008"
      },
      {
        "db": "BID",
        "id": "105341"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010414"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-577"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14811"
      }
    ]
  },
  "sources": {
    "_id": null,
    "data": [
      {
        "db": "IVD",
        "id": "7d85de80-463f-11e9-8522-000c29342cb1",
        "ident": null
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1014",
        "ident": null
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1011",
        "ident": null
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1020",
        "ident": null
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1022",
        "ident": null
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1021",
        "ident": null
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-03306",
        "ident": null
      },
      {
        "db": "VULHUB",
        "id": "VHN-125008",
        "ident": null
      },
      {
        "db": "BID",
        "id": "105341",
        "ident": null
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010414",
        "ident": null
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-577",
        "ident": null
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14811",
        "ident": null
      }
    ]
  },
  "sources_release_date": {
    "_id": null,
    "data": [
      {
        "date": "2019-01-30T00:00:00",
        "db": "IVD",
        "id": "7d85de80-463f-11e9-8522-000c29342cb1",
        "ident": null
      },
      {
        "date": "2018-09-12T00:00:00",
        "db": "ZDI",
        "id": "ZDI-18-1014",
        "ident": null
      },
      {
        "date": "2018-09-12T00:00:00",
        "db": "ZDI",
        "id": "ZDI-18-1011",
        "ident": null
      },
      {
        "date": "2018-09-12T00:00:00",
        "db": "ZDI",
        "id": "ZDI-18-1020",
        "ident": null
      },
      {
        "date": "2018-09-12T00:00:00",
        "db": "ZDI",
        "id": "ZDI-18-1022",
        "ident": null
      },
      {
        "date": "2018-09-12T00:00:00",
        "db": "ZDI",
        "id": "ZDI-18-1021",
        "ident": null
      },
      {
        "date": "2019-01-30T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-03306",
        "ident": null
      },
      {
        "date": "2018-09-26T00:00:00",
        "db": "VULHUB",
        "id": "VHN-125008",
        "ident": null
      },
      {
        "date": "2018-09-11T00:00:00",
        "db": "BID",
        "id": "105341",
        "ident": null
      },
      {
        "date": "2018-12-13T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-010414",
        "ident": null
      },
      {
        "date": "2018-09-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201809-577",
        "ident": null
      },
      {
        "date": "2018-09-26T20:29:00.403000",
        "db": "NVD",
        "id": "CVE-2018-14811",
        "ident": null
      }
    ]
  },
  "sources_update_date": {
    "_id": null,
    "data": [
      {
        "date": "2018-09-12T00:00:00",
        "db": "ZDI",
        "id": "ZDI-18-1014",
        "ident": null
      },
      {
        "date": "2018-09-12T00:00:00",
        "db": "ZDI",
        "id": "ZDI-18-1011",
        "ident": null
      },
      {
        "date": "2018-09-12T00:00:00",
        "db": "ZDI",
        "id": "ZDI-18-1020",
        "ident": null
      },
      {
        "date": "2018-09-12T00:00:00",
        "db": "ZDI",
        "id": "ZDI-18-1022",
        "ident": null
      },
      {
        "date": "2018-09-12T00:00:00",
        "db": "ZDI",
        "id": "ZDI-18-1021",
        "ident": null
      },
      {
        "date": "2019-01-30T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-03306",
        "ident": null
      },
      {
        "date": "2019-10-09T00:00:00",
        "db": "VULHUB",
        "id": "VHN-125008",
        "ident": null
      },
      {
        "date": "2018-09-11T00:00:00",
        "db": "BID",
        "id": "105341",
        "ident": null
      },
      {
        "date": "2018-12-13T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-010414",
        "ident": null
      },
      {
        "date": "2019-10-17T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201809-577",
        "ident": null
      },
      {
        "date": "2024-11-21T03:49:50.773000",
        "db": "NVD",
        "id": "CVE-2018-14811",
        "ident": null
      }
    ]
  },
  "threat_type": {
    "_id": null,
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-577"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "_id": null,
    "data": "Fuji Electric V-Server VPR File Parsing CArchive Read Untrusted Pointer Dereference Remote Code Execution Vulnerability",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-18-1011"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1020"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1021"
      }
    ],
    "trust": 2.1
  },
  "type": {
    "_id": null,
    "data": "Code problem",
    "sources": [
      {
        "db": "IVD",
        "id": "7d85de80-463f-11e9-8522-000c29342cb1"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-577"
      }
    ],
    "trust": 0.8
  }
}

var-202101-1104
Vulnerability from variot

An uninitialized pointer issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0). V-Simulator and V-Server Lite There is a vulnerability in accessing uninitialized pointers.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric V-Server Lite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of VPR files. The issue results from the lack of proper initialization of a pointer prior to accessing it. An attacker can leverage this vulnerability to execute code in the context of the current process. Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite are both products of Fuji Electric, Japan. The software can collect information about PLCs, temperature controllers, inverters and other equipment

Show details on source website


{
  "affected_products": {
    "_id": null,
    "data": [
      {
        "_id": null,
        "model": "v-server",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "4.0.10.0"
      },
      {
        "_id": null,
        "model": "v-simulator",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "4.0.10.0"
      },
      {
        "_id": null,
        "model": "v-simulator",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u5bcc\u58eb\u96fb\u6a5f",
        "version": "lite 4.0.10.0"
      },
      {
        "_id": null,
        "model": "v-server",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u5bcc\u58eb\u96fb\u6a5f",
        "version": null
      },
      {
        "_id": null,
        "model": "v-server lite",
        "scope": null,
        "trust": 0.7,
        "vendor": "fuji electric",
        "version": null
      },
      {
        "_id": null,
        "model": "electric tellus lite v-simulator",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "fuji",
        "version": "4.0.10.0"
      },
      {
        "_id": null,
        "model": "electric v-server lite",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "fuji",
        "version": "4.0.10.0"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-098"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17708"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002820"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22639"
      }
    ]
  },
  "credits": {
    "_id": null,
    "data": "khangkito - Tran Van Khang of VinCSS (Member of Vingroup)",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-098"
      }
    ],
    "trust": 0.7
  },
  "cve": "CVE-2021-22639",
  "cvss": {
    "_id": null,
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CVE-2021-22639",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.9,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CNVD-2021-17708",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2021-22639",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Local",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2021-22639",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "Required",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "ZDI",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2021-22639",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 0.7,
            "userInteraction": "REQUIRED",
            "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2021-22639",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2021-22639",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "ZDI",
            "id": "CVE-2021-22639",
            "trust": 0.7,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2021-17708",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202101-2398",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2021-22639",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-098"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17708"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22639"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002820"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2398"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22639"
      }
    ]
  },
  "description": {
    "_id": null,
    "data": "An uninitialized pointer issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0). V-Simulator and V-Server Lite There is a vulnerability in accessing uninitialized pointers.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric V-Server Lite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of VPR files. The issue results from the lack of proper initialization of a pointer prior to accessing it. An attacker can leverage this vulnerability to execute code in the context of the current process. Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite are both products of Fuji Electric, Japan. The software can collect information about PLCs, temperature controllers, inverters and other equipment",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-22639"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002820"
      },
      {
        "db": "ZDI",
        "id": "ZDI-21-098"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17708"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22639"
      }
    ],
    "trust": 2.88
  },
  "external_ids": {
    "_id": null,
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2021-22639",
        "trust": 3.8
      },
      {
        "db": "ZDI",
        "id": "ZDI-21-098",
        "trust": 3.2
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-21-026-01",
        "trust": 3.1
      },
      {
        "db": "JVN",
        "id": "JVNVU93293369",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002820",
        "trust": 0.8
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-11668",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17708",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2021.0297",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2398",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22639",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-098"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17708"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22639"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002820"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2398"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22639"
      }
    ]
  },
  "id": "VAR-202101-1104",
  "iot": {
    "_id": null,
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17708"
      }
    ],
    "trust": 1.53529412
  },
  "iot_taxonomy": {
    "_id": null,
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17708"
      }
    ]
  },
  "last_update_date": "2024-11-23T20:26:42.576000Z",
  "patch": {
    "_id": null,
    "data": [
      {
        "title": "Top\u00a0Page",
        "trust": 0.8,
        "url": "https://www.fujielectric.com/index.html"
      },
      {
        "title": "Fuji Electric has issued an update to correct this vulnerability.",
        "trust": 0.7,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
      },
      {
        "title": "Patch for Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite buffer overflow vulnerability (CNVD-2021-17708)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/252906"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-098"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17708"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002820"
      }
    ]
  },
  "problemtype_data": {
    "_id": null,
    "data": [
      {
        "problemtype": "CWE-824",
        "trust": 1.0
      },
      {
        "problemtype": "Accessing uninitialized pointers (CWE-824) [NVD Evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002820"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22639"
      }
    ]
  },
  "references": {
    "_id": null,
    "data": [
      {
        "trust": 4.4,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
      },
      {
        "trust": 2.5,
        "url": "https://www.zerodayinitiative.com/advisories/zdi-21-098/"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-22639"
      },
      {
        "trust": 0.8,
        "url": "http://jvn.jp/vu/jvnvu93293369/index.html"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2021.0297/"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/824.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/195684"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-098"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17708"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22639"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002820"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2398"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22639"
      }
    ]
  },
  "sources": {
    "_id": null,
    "data": [
      {
        "db": "ZDI",
        "id": "ZDI-21-098",
        "ident": null
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17708",
        "ident": null
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22639",
        "ident": null
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002820",
        "ident": null
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2398",
        "ident": null
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22639",
        "ident": null
      }
    ]
  },
  "sources_release_date": {
    "_id": null,
    "data": [
      {
        "date": "2021-01-29T00:00:00",
        "db": "ZDI",
        "id": "ZDI-21-098",
        "ident": null
      },
      {
        "date": "2021-03-16T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-17708",
        "ident": null
      },
      {
        "date": "2021-01-27T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-22639",
        "ident": null
      },
      {
        "date": "2021-10-05T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-002820",
        "ident": null
      },
      {
        "date": "2021-01-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-2398",
        "ident": null
      },
      {
        "date": "2021-01-27T20:15:12.847000",
        "db": "NVD",
        "id": "CVE-2021-22639",
        "ident": null
      }
    ]
  },
  "sources_update_date": {
    "_id": null,
    "data": [
      {
        "date": "2021-06-29T00:00:00",
        "db": "ZDI",
        "id": "ZDI-21-098",
        "ident": null
      },
      {
        "date": "2021-03-16T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-17708",
        "ident": null
      },
      {
        "date": "2021-01-29T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-22639",
        "ident": null
      },
      {
        "date": "2021-10-05T08:53:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-002820",
        "ident": null
      },
      {
        "date": "2021-02-01T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-2398",
        "ident": null
      },
      {
        "date": "2024-11-21T05:50:21.947000",
        "db": "NVD",
        "id": "CVE-2021-22639",
        "ident": null
      }
    ]
  },
  "threat_type": {
    "_id": null,
    "data": "local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2398"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "_id": null,
    "data": "V-Simulator\u00a0 and \u00a0V-Server\u00a0Lite\u00a0 Vulnerability in accessing uninitialized pointers in",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002820"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "_id": null,
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2398"
      }
    ],
    "trust": 0.6
  }
}

var-202101-1105
Vulnerability from variot

A heap-based buffer overflow issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0). V-Simulator and V-Server Lite Is vulnerable to an out-of-bounds write.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric V-Server Lite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of VPR files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite are both products of Fuji Electric, Japan. The software can collect information about PLCs, temperature controllers, inverters and other equipment

Show details on source website


{
  "affected_products": {
    "_id": null,
    "data": [
      {
        "_id": null,
        "model": "v-server",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "4.0.10.0"
      },
      {
        "_id": null,
        "model": "v-simulator",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "4.0.10.0"
      },
      {
        "_id": null,
        "model": "v-simulator",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u5bcc\u58eb\u96fb\u6a5f",
        "version": "lite 4.0.10.0"
      },
      {
        "_id": null,
        "model": "v-server",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u5bcc\u58eb\u96fb\u6a5f",
        "version": null
      },
      {
        "_id": null,
        "model": "v-server lite",
        "scope": null,
        "trust": 0.7,
        "vendor": "fuji electric",
        "version": null
      },
      {
        "_id": null,
        "model": "electric tellus lite v-simulator",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "fuji",
        "version": "4.0.10.0"
      },
      {
        "_id": null,
        "model": "electric v-server lite",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "fuji",
        "version": "4.0.10.0"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-099"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17707"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002821"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22641"
      }
    ]
  },
  "credits": {
    "_id": null,
    "data": "khangkito - Tran Van Khang of VinCSS (Member of Vingroup)",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-099"
      }
    ],
    "trust": 0.7
  },
  "cve": "CVE-2021-22641",
  "cvss": {
    "_id": null,
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CVE-2021-22641",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.9,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CNVD-2021-17707",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2021-22641",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Local",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2021-22641",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "Required",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "ZDI",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2021-22641",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 0.7,
            "userInteraction": "REQUIRED",
            "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2021-22641",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2021-22641",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "ZDI",
            "id": "CVE-2021-22641",
            "trust": 0.7,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2021-17707",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202101-2393",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2021-22641",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-099"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17707"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22641"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002821"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2393"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22641"
      }
    ]
  },
  "description": {
    "_id": null,
    "data": "A heap-based buffer overflow issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0). V-Simulator and V-Server Lite Is vulnerable to an out-of-bounds write.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric V-Server Lite.  User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of VPR files.  The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer.  An attacker can leverage this vulnerability to execute code in the context of the current process. Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite are both products of Fuji Electric, Japan. The software can collect information about PLCs, temperature controllers, inverters and other equipment",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-22641"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002821"
      },
      {
        "db": "ZDI",
        "id": "ZDI-21-099"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17707"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22641"
      }
    ],
    "trust": 2.88
  },
  "external_ids": {
    "_id": null,
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2021-22641",
        "trust": 3.8
      },
      {
        "db": "ZDI",
        "id": "ZDI-21-099",
        "trust": 3.2
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-21-026-01",
        "trust": 3.1
      },
      {
        "db": "JVN",
        "id": "JVNVU93293369",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002821",
        "trust": 0.8
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-11669",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17707",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2021.0297",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2393",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22641",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-099"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17707"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22641"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002821"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2393"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22641"
      }
    ]
  },
  "id": "VAR-202101-1105",
  "iot": {
    "_id": null,
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17707"
      }
    ],
    "trust": 1.53529412
  },
  "iot_taxonomy": {
    "_id": null,
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17707"
      }
    ]
  },
  "last_update_date": "2024-11-23T21:26:42.245000Z",
  "patch": {
    "_id": null,
    "data": [
      {
        "title": "Top\u00a0Page",
        "trust": 0.8,
        "url": "https://www.fujielectric.com/index.html"
      },
      {
        "title": "Fuji Electric has issued an update to correct this vulnerability.",
        "trust": 0.7,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
      },
      {
        "title": "Patch for Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite buffer overflow vulnerability (CNVD-2021-17707)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/252926"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-099"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17707"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002821"
      }
    ]
  },
  "problemtype_data": {
    "_id": null,
    "data": [
      {
        "problemtype": "CWE-122",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002821"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22641"
      }
    ]
  },
  "references": {
    "_id": null,
    "data": [
      {
        "trust": 4.4,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
      },
      {
        "trust": 2.5,
        "url": "https://www.zerodayinitiative.com/advisories/zdi-21-099/"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-22641"
      },
      {
        "trust": 0.8,
        "url": "http://jvn.jp/vu/jvnvu93293369/index.html"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2021.0297/"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/787.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-099"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17707"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22641"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002821"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2393"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22641"
      }
    ]
  },
  "sources": {
    "_id": null,
    "data": [
      {
        "db": "ZDI",
        "id": "ZDI-21-099",
        "ident": null
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17707",
        "ident": null
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22641",
        "ident": null
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002821",
        "ident": null
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2393",
        "ident": null
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22641",
        "ident": null
      }
    ]
  },
  "sources_release_date": {
    "_id": null,
    "data": [
      {
        "date": "2021-01-29T00:00:00",
        "db": "ZDI",
        "id": "ZDI-21-099",
        "ident": null
      },
      {
        "date": "2021-03-16T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-17707",
        "ident": null
      },
      {
        "date": "2021-01-27T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-22641",
        "ident": null
      },
      {
        "date": "2021-10-05T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-002821",
        "ident": null
      },
      {
        "date": "2021-01-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-2393",
        "ident": null
      },
      {
        "date": "2021-01-27T20:15:13.207000",
        "db": "NVD",
        "id": "CVE-2021-22641",
        "ident": null
      }
    ]
  },
  "sources_update_date": {
    "_id": null,
    "data": [
      {
        "date": "2021-06-29T00:00:00",
        "db": "ZDI",
        "id": "ZDI-21-099",
        "ident": null
      },
      {
        "date": "2021-03-16T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-17707",
        "ident": null
      },
      {
        "date": "2021-01-29T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-22641",
        "ident": null
      },
      {
        "date": "2021-10-05T08:53:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-002821",
        "ident": null
      },
      {
        "date": "2021-02-01T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-2393",
        "ident": null
      },
      {
        "date": "2024-11-21T05:50:22.220000",
        "db": "NVD",
        "id": "CVE-2021-22641",
        "ident": null
      }
    ]
  },
  "threat_type": {
    "_id": null,
    "data": "local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2393"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "_id": null,
    "data": "V-Simulator\u00a0 and \u00a0V-Server\u00a0Lite\u00a0 Out-of-bounds Vulnerability in Microsoft",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002821"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "_id": null,
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2393"
      }
    ],
    "trust": 0.6
  }
}

var-202101-0898
Vulnerability from variot

Multiple out-of-bounds read issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0). V-Simulator and V-Server Lite Is vulnerable to an out-of-bounds read.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite are both products of Fuji Electric, Japan. Fuji Electric Tellus Lite V-Simulator is a remote monitoring software for industrial environments. Fuji Electric V-Server Lite is a remote monitoring software for industrial environments. The software can collect information about PLCs, temperature controllers, inverters and other equipment.

Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite have an out-of-bounds read vulnerability. Attackers can use this vulnerability to execute arbitrary code

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202101-0898",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "v-server",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "4.0.10.0"
      },
      {
        "model": "v-simulator",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "4.0.10.0"
      },
      {
        "model": "v-simulator",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u5bcc\u58eb\u96fb\u6a5f",
        "version": "lite 4.0.10.0"
      },
      {
        "model": "v-server",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u5bcc\u58eb\u96fb\u6a5f",
        "version": null
      },
      {
        "model": "electric tellus lite v-simulator",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "fuji",
        "version": "4.0.10.0"
      },
      {
        "model": "electric v-server lite",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "fuji",
        "version": "4.0.10.0"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17710"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002823"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22655"
      }
    ]
  },
  "cve": "CVE-2021-22655",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CVE-2021-22655",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.9,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CNVD-2021-17710",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2021-22655",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Local",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2021-22655",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "Required",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2021-22655",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2021-22655",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2021-17710",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202101-2403",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2021-22655",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17710"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22655"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002823"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2403"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22655"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Multiple out-of-bounds read issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0). V-Simulator and V-Server Lite Is vulnerable to an out-of-bounds read.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite are both products of Fuji Electric, Japan. Fuji Electric Tellus Lite V-Simulator is a remote monitoring software for industrial environments. Fuji Electric V-Server Lite is a remote monitoring software for industrial environments. The software can collect information about PLCs, temperature controllers, inverters and other equipment. \n\r\n\r\nFuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite have an out-of-bounds read vulnerability. Attackers can use this vulnerability to execute arbitrary code",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-22655"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002823"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17710"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22655"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2021-22655",
        "trust": 3.1
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-21-026-01",
        "trust": 3.1
      },
      {
        "db": "JVN",
        "id": "JVNVU93293369",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002823",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17710",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2021.0297",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2403",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22655",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17710"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22655"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002823"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2403"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22655"
      }
    ]
  },
  "id": "VAR-202101-0898",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17710"
      }
    ],
    "trust": 1.53529412
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17710"
      }
    ]
  },
  "last_update_date": "2024-11-23T20:48:55.682000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top\u00a0Page",
        "trust": 0.8,
        "url": "https://www.fujielectric.com/index.html"
      },
      {
        "title": "Patch for Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite out-of-bounds read vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/252816"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17710"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002823"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-125",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds read (CWE-125) [NVD Evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002823"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22655"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-22655"
      },
      {
        "trust": 0.8,
        "url": "http://jvn.jp/vu/jvnvu93293369/index.html"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2021.0297/"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/125.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17710"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22655"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002823"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2403"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22655"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17710"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22655"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002823"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2403"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22655"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-03-16T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-17710"
      },
      {
        "date": "2021-01-27T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-22655"
      },
      {
        "date": "2021-10-05T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-002823"
      },
      {
        "date": "2021-01-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-2403"
      },
      {
        "date": "2021-01-27T20:15:13.397000",
        "db": "NVD",
        "id": "CVE-2021-22655"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-03-16T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-17710"
      },
      {
        "date": "2021-01-29T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-22655"
      },
      {
        "date": "2021-10-05T08:53:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-002823"
      },
      {
        "date": "2021-02-01T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-2403"
      },
      {
        "date": "2024-11-21T05:50:24.890000",
        "db": "NVD",
        "id": "CVE-2021-22655"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2403"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "V-Simulator\u00a0 and \u00a0V-Server\u00a0Lite\u00a0 Out-of-bounds read vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002823"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2403"
      }
    ],
    "trust": 0.6
  }
}

var-202102-0298
Vulnerability from variot

The affected Fuji Electric V-Server Lite versions prior to 3.3.24.0 are vulnerable to an out-of-bounds write, which may allow an attacker to remotely execute arbitrary code. Provided by Fuji Electric Co., Ltd. V-Server Lite Is an industrial software that collects production information in real time. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of VPR files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated data structure. An attacker can leverage this vulnerability to execute code in the context of the current process

Show details on source website


{
  "affected_products": {
    "_id": null,
    "data": [
      {
        "_id": null,
        "model": "v-server",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "3.3.24.0"
      },
      {
        "_id": null,
        "model": "v-server",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "fuji electric",
        "version": "lite 3.3.24.0 \u306e\u5168\u3066"
      },
      {
        "_id": null,
        "model": "v-server lite",
        "scope": null,
        "trust": 0.7,
        "vendor": "fuji electric",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-20-1384"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-009656"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-25171"
      }
    ]
  },
  "configurations": {
    "_id": null,
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "3.3.24.0",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-25171"
      }
    ]
  },
  "credits": {
    "_id": null,
    "data": "Tran Van Khang - khangkito of VinCSS (Member of Vingroup)",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-20-1384"
      }
    ],
    "trust": 0.7
  },
  "cve": "CVE-2020-25171",
  "cvss": {
    "_id": null,
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CVE-2020-25171",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": true,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2020-25171",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Local",
            "author": "IPA score",
            "availabilityImpact": "High",
            "baseScore": 7.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-009656",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "Required",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "ZDI",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2020-25171",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 0.7,
            "userInteraction": "REQUIRED",
            "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2020-25171",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "IPA",
            "id": "JVNDB-2020-009656",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "ZDI",
            "id": "CVE-2020-25171",
            "trust": 0.7,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202011-1837",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-20-1384"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-009656"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202011-1837"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-25171"
      }
    ]
  },
  "description": {
    "_id": null,
    "data": "The affected Fuji Electric V-Server Lite versions prior to 3.3.24.0 are vulnerable to an out-of-bounds write, which may allow an attacker to remotely execute arbitrary code. Provided by Fuji Electric Co., Ltd. V-Server Lite Is an industrial software that collects production information in real time. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of VPR files.  The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated data structure. An attacker can leverage this vulnerability to execute code in the context of the current process",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-25171"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-009656"
      },
      {
        "db": "ZDI",
        "id": "ZDI-20-1384"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "_id": null,
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-25171",
        "trust": 3.1
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-20-329-02",
        "trust": 2.4
      },
      {
        "db": "JVN",
        "id": "JVNVU97620058",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-009656",
        "trust": 0.8
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-11353",
        "trust": 0.7
      },
      {
        "db": "ZDI",
        "id": "ZDI-20-1384",
        "trust": 0.7
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2020.4169",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202011-1837",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-20-1384"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-009656"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202011-1837"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-25171"
      }
    ]
  },
  "id": "VAR-202102-0298",
  "iot": {
    "_id": null,
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.41666666
  },
  "last_update_date": "2022-05-04T09:42:08.814000Z",
  "patch": {
    "_id": null,
    "data": [
      {
        "title": "Fe Library | Search Remote Control Software Documents (\u8981\u30ed\u30b0\u30a4\u30f3)",
        "trust": 0.8,
        "url": "https://felib.fujielectric.co.jp/download/pod_document.htm?product1_id=p10003\u0026product2_id=p20023\u0026product3_id=p30262\u0026material1_id=m10009\u0026site=global\u0026lang=en"
      },
      {
        "title": "Fuji Electric has issued an update to correct this vulnerability.",
        "trust": 0.7,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-329-02"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-20-1384"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-009656"
      }
    ]
  },
  "problemtype_data": {
    "_id": null,
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-009656"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-25171"
      }
    ]
  },
  "references": {
    "_id": null,
    "data": [
      {
        "trust": 3.1,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-329-02"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-25171"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu97620058"
      },
      {
        "trust": 0.6,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-25171"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2020.4169/"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-20-1384"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-009656"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202011-1837"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-25171"
      }
    ]
  },
  "sources": {
    "_id": null,
    "data": [
      {
        "db": "ZDI",
        "id": "ZDI-20-1384",
        "ident": null
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-009656",
        "ident": null
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202011-1837",
        "ident": null
      },
      {
        "db": "NVD",
        "id": "CVE-2020-25171",
        "ident": null
      }
    ]
  },
  "sources_release_date": {
    "_id": null,
    "data": [
      {
        "date": "2020-11-25T00:00:00",
        "db": "ZDI",
        "id": "ZDI-20-1384",
        "ident": null
      },
      {
        "date": "2020-11-26T06:26:17",
        "db": "JVNDB",
        "id": "JVNDB-2020-009656",
        "ident": null
      },
      {
        "date": "2020-11-24T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202011-1837",
        "ident": null
      },
      {
        "date": "2021-02-19T18:15:00",
        "db": "NVD",
        "id": "CVE-2020-25171",
        "ident": null
      }
    ]
  },
  "sources_update_date": {
    "_id": null,
    "data": [
      {
        "date": "2020-11-25T00:00:00",
        "db": "ZDI",
        "id": "ZDI-20-1384",
        "ident": null
      },
      {
        "date": "2020-11-26T06:26:17",
        "db": "JVNDB",
        "id": "JVNDB-2020-009656",
        "ident": null
      },
      {
        "date": "2021-02-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202011-1837",
        "ident": null
      },
      {
        "date": "2021-02-25T22:16:00",
        "db": "NVD",
        "id": "CVE-2020-25171",
        "ident": null
      }
    ]
  },
  "threat_type": {
    "_id": null,
    "data": "local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202011-1837"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "_id": null,
    "data": "Made by Fuji Electric  V-Server Lite Out-of-bounds write vulnerability in",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-009656"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "_id": null,
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202011-1837"
      }
    ],
    "trust": 0.6
  }
}

var-201809-0155
Vulnerability from variot

Fuji Electric V-Server 4.0.3.0 and prior, An out-of-bounds read vulnerability has been identified, which may allow remote code execution. Fuji Electric V-Server Contains an out-of-bounds vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of a VPR file. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code under the context of the V-Server process. Fuji Electric V-Server VPR is a data collection software from Fuji Electric of Japan. Fuji Electric V-Server is prone to multiple security vulnerabilities: 1. A use-after-free vulnerability 2. Multiple untrusted pointer dereference remote code-execution vulnerabilities 3. A heap-based buffer overflow vulnerability 4. Multiple out-of-bounds write vulnerabilities 5. An integer underflow vulnerability 6. An out-of-bounds read vulnerability 7. V-Server 4.0.3.0 and prior are vulnerable

Show details on source website


{
  "affected_products": {
    "_id": null,
    "data": [
      {
        "_id": null,
        "model": "v-server",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "4.0.3.0"
      },
      {
        "_id": null,
        "model": "v-server",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "fuji electric",
        "version": "4.0.3.0"
      },
      {
        "_id": null,
        "model": "v-server",
        "scope": null,
        "trust": 0.7,
        "vendor": "fuji electric",
        "version": null
      },
      {
        "_id": null,
        "model": "electric v-server vpr",
        "scope": "lte",
        "trust": 0.6,
        "vendor": "fuji",
        "version": "\u003c=4.0.3.0"
      },
      {
        "_id": null,
        "model": "v-server",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "fujielectric",
        "version": "4.0.3.0"
      },
      {
        "_id": null,
        "model": "electric v-server",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "4.0.3.0"
      },
      {
        "_id": null,
        "model": "electric v-server",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "4.0.1.0"
      },
      {
        "_id": null,
        "model": "electric v-server",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "4.0.0.0"
      },
      {
        "_id": null,
        "model": "electric v-server",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "3.3.22.0"
      },
      {
        "_id": null,
        "model": "electric v-server",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "4.0.4.0"
      },
      {
        "_id": null,
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "v server",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2fd422f-39ab-11e9-af52-000c29342cb1"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1018"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20780"
      },
      {
        "db": "BID",
        "id": "105341"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010430"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-581"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14819"
      }
    ]
  },
  "configurations": {
    "_id": null,
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:fujielectric:v-server_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010430"
      }
    ]
  },
  "credits": {
    "_id": null,
    "data": "Steven Seeley (mr_me) of Source Incite",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-18-1018"
      }
    ],
    "trust": 0.7
  },
  "cve": "CVE-2018-14819",
  "cvss": {
    "_id": null,
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-14819",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "ZDI",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CVE-2018-14819",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "MEDIUM",
            "trust": 0.7,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2018-20780",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "e2fd422f-39ab-11e9-af52-000c29342cb1",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "VHN-125016",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-14819",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-14819",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-14819",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "ZDI",
            "id": "CVE-2018-14819",
            "trust": 0.7,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2018-20780",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201809-581",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "IVD",
            "id": "e2fd422f-39ab-11e9-af52-000c29342cb1",
            "trust": 0.2,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-125016",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2fd422f-39ab-11e9-af52-000c29342cb1"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1018"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20780"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125016"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010430"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-581"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14819"
      }
    ]
  },
  "description": {
    "_id": null,
    "data": "Fuji Electric V-Server 4.0.3.0 and prior, An out-of-bounds read vulnerability has been identified, which may allow remote code execution. Fuji Electric V-Server Contains an out-of-bounds vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of a VPR file. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code under the context of the V-Server process. Fuji Electric V-Server VPR is a data collection software from Fuji Electric of Japan. Fuji Electric V-Server is prone to multiple security vulnerabilities:\n1. A use-after-free vulnerability\n2. Multiple untrusted pointer dereference remote code-execution vulnerabilities\n3. A heap-based buffer overflow vulnerability\n4. Multiple out-of-bounds write vulnerabilities\n5. An integer underflow vulnerability\n6. An out-of-bounds read vulnerability\n7. \nV-Server 4.0.3.0 and prior are vulnerable",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-14819"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010430"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1018"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20780"
      },
      {
        "db": "BID",
        "id": "105341"
      },
      {
        "db": "IVD",
        "id": "e2fd422f-39ab-11e9-af52-000c29342cb1"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125016"
      }
    ],
    "trust": 3.33
  },
  "external_ids": {
    "_id": null,
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-14819",
        "trust": 4.3
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-18-254-01",
        "trust": 2.8
      },
      {
        "db": "BID",
        "id": "105341",
        "trust": 2.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-581",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20780",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010430",
        "trust": 0.8
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-5884",
        "trust": 0.7
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1018",
        "trust": 0.7
      },
      {
        "db": "IVD",
        "id": "E2FD422F-39AB-11E9-AF52-000C29342CB1",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-125016",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2fd422f-39ab-11e9-af52-000c29342cb1"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1018"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20780"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125016"
      },
      {
        "db": "BID",
        "id": "105341"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010430"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-581"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14819"
      }
    ]
  },
  "id": "VAR-201809-0155",
  "iot": {
    "_id": null,
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "e2fd422f-39ab-11e9-af52-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20780"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125016"
      }
    ],
    "trust": 1.77058824
  },
  "iot_taxonomy": {
    "_id": null,
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2fd422f-39ab-11e9-af52-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20780"
      }
    ]
  },
  "last_update_date": "2024-11-23T21:38:23.853000Z",
  "patch": {
    "_id": null,
    "data": [
      {
        "title": "\u30c8\u30c3\u30d7\u30da\u30fc\u30b8",
        "trust": 0.8,
        "url": "http://www.fujielectric.co.jp/"
      },
      {
        "title": "Fuji Electric has issued an update to correct this vulnerability.",
        "trust": 0.7,
        "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
      },
      {
        "title": "Fuji Electric V-Server cross-border read vulnerability patch",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/142203"
      },
      {
        "title": "Fuji Electric V-Server VPR Buffer error vulnerability fix",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=84848"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-18-1018"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20780"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010430"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-581"
      }
    ]
  },
  "problemtype_data": {
    "_id": null,
    "data": [
      {
        "problemtype": "CWE-125",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-125016"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010430"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14819"
      }
    ]
  },
  "references": {
    "_id": null,
    "data": [
      {
        "trust": 3.5,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-254-01"
      },
      {
        "trust": 2.3,
        "url": "http://www.securityfocus.com/bid/105341"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14819"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-14819"
      },
      {
        "trust": 0.3,
        "url": "http://www.fujielectric.com/"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-18-1018"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20780"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125016"
      },
      {
        "db": "BID",
        "id": "105341"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010430"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-581"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14819"
      }
    ]
  },
  "sources": {
    "_id": null,
    "data": [
      {
        "db": "IVD",
        "id": "e2fd422f-39ab-11e9-af52-000c29342cb1",
        "ident": null
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1018",
        "ident": null
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20780",
        "ident": null
      },
      {
        "db": "VULHUB",
        "id": "VHN-125016",
        "ident": null
      },
      {
        "db": "BID",
        "id": "105341",
        "ident": null
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010430",
        "ident": null
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-581",
        "ident": null
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14819",
        "ident": null
      }
    ]
  },
  "sources_release_date": {
    "_id": null,
    "data": [
      {
        "date": "2018-10-12T00:00:00",
        "db": "IVD",
        "id": "e2fd422f-39ab-11e9-af52-000c29342cb1",
        "ident": null
      },
      {
        "date": "2018-09-12T00:00:00",
        "db": "ZDI",
        "id": "ZDI-18-1018",
        "ident": null
      },
      {
        "date": "2018-10-12T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-20780",
        "ident": null
      },
      {
        "date": "2018-09-26T00:00:00",
        "db": "VULHUB",
        "id": "VHN-125016",
        "ident": null
      },
      {
        "date": "2018-09-11T00:00:00",
        "db": "BID",
        "id": "105341",
        "ident": null
      },
      {
        "date": "2018-12-14T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-010430",
        "ident": null
      },
      {
        "date": "2018-09-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201809-581",
        "ident": null
      },
      {
        "date": "2018-09-26T20:29:00.870000",
        "db": "NVD",
        "id": "CVE-2018-14819",
        "ident": null
      }
    ]
  },
  "sources_update_date": {
    "_id": null,
    "data": [
      {
        "date": "2018-09-12T00:00:00",
        "db": "ZDI",
        "id": "ZDI-18-1018",
        "ident": null
      },
      {
        "date": "2018-10-12T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-20780",
        "ident": null
      },
      {
        "date": "2019-10-09T00:00:00",
        "db": "VULHUB",
        "id": "VHN-125016",
        "ident": null
      },
      {
        "date": "2018-09-11T00:00:00",
        "db": "BID",
        "id": "105341",
        "ident": null
      },
      {
        "date": "2018-12-14T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-010430",
        "ident": null
      },
      {
        "date": "2019-10-17T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201809-581",
        "ident": null
      },
      {
        "date": "2024-11-21T03:49:51.803000",
        "db": "NVD",
        "id": "CVE-2018-14819",
        "ident": null
      }
    ]
  },
  "threat_type": {
    "_id": null,
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-581"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "_id": null,
    "data": "Fuji Electric V-Server Vulnerable to out-of-bounds reading",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010430"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "_id": null,
    "data": "Buffer error",
    "sources": [
      {
        "db": "IVD",
        "id": "e2fd422f-39ab-11e9-af52-000c29342cb1"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-581"
      }
    ],
    "trust": 0.8
  }
}

var-201906-0328
Vulnerability from variot

Fuji Electric V-Server before 6.0.33.0 stores database credentials in project files as plaintext. An attacker that can gain access to the project file can recover the database credentials and gain access to the database server. Fuji Electric V-Server Contains vulnerabilities related to certificate and password management.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Fuji Electric V-Server is prone to multiple security vulnerabilities: 1. A remote denial-of-service vulnerability 2. An information disclosure vulnerability An attacker can exploit these issues to cause a denial-of-service condition or obtain sensitive information that may lead to further attacks . Versions prior to V-SFT 6.0.33.0 are vulnerable

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201906-0328",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "v-server",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "6.0.33.0"
      },
      {
        "model": "v-server",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "fuji electric",
        "version": "6.0.33.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.9.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.8.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.7.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.6.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.5.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.4.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.32.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.31.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.30.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.3.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.29.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.28.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.27.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.26.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.25.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.24.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.23.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.22.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.21.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.20.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.2.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.19.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.18.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.17.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.16.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.15.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.14.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.13.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.12.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.11.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.10.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.33.0"
      }
    ],
    "sources": [
      {
        "db": "BID",
        "id": "108740"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005462"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-3947"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:fujielectric:v-server",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005462"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenable",
    "sources": [
      {
        "db": "BID",
        "id": "108740"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-558"
      }
    ],
    "trust": 0.9
  },
  "cve": "CVE-2019-3947",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2019-3947",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.9,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2019-3947",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2019-3947",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2019-3947",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201906-558",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULMON",
            "id": "CVE-2019-3947",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2019-3947"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005462"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-558"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-3947"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Fuji Electric V-Server before 6.0.33.0 stores database credentials in project files as plaintext. An attacker that can gain access to the project file can recover the database credentials and gain access to the database server. Fuji Electric V-Server Contains vulnerabilities related to certificate and password management.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Fuji Electric V-Server is prone to multiple security vulnerabilities:\n1. A remote denial-of-service vulnerability\n2. An information disclosure vulnerability\nAn attacker can exploit these issues to cause a denial-of-service condition or obtain sensitive information that may lead to further attacks . \nVersions prior to V-SFT 6.0.33.0 are vulnerable",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-3947"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005462"
      },
      {
        "db": "BID",
        "id": "108740"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-3947"
      }
    ],
    "trust": 1.98
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "TENABLE",
        "id": "TRA-2019-27",
        "trust": 2.8
      },
      {
        "db": "NVD",
        "id": "CVE-2019-3947",
        "trust": 2.8
      },
      {
        "db": "BID",
        "id": "108740",
        "trust": 2.0
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005462",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-558",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-3947",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2019-3947"
      },
      {
        "db": "BID",
        "id": "108740"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005462"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-558"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-3947"
      }
    ]
  },
  "id": "VAR-201906-0328",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.65
  },
  "last_update_date": "2024-11-23T22:33:54.379000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "V-Server",
        "trust": 0.8,
        "url": "https://monitouch.fujielectric.com/site/tellus-e/tellus03-01.html"
      },
      {
        "title": "Fuji Electric V-Server Repair measures for trust management problem vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=93790"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005462"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-558"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-522",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-255",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005462"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-3947"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.8,
        "url": "https://www.tenable.com/security/research/tra-2019-27"
      },
      {
        "trust": 1.8,
        "url": "http://www.securityfocus.com/bid/108740"
      },
      {
        "trust": 0.9,
        "url": "http://www.fujielectric.com/"
      },
      {
        "trust": 0.9,
        "url": "https://monitouch.fujielectric.com/site/support-e/more-index-t.html"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-3947"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-3947"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/522.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2019-3947"
      },
      {
        "db": "BID",
        "id": "108740"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005462"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-558"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-3947"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULMON",
        "id": "CVE-2019-3947"
      },
      {
        "db": "BID",
        "id": "108740"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005462"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-558"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-3947"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-06-12T00:00:00",
        "db": "VULMON",
        "id": "CVE-2019-3947"
      },
      {
        "date": "2019-06-11T00:00:00",
        "db": "BID",
        "id": "108740"
      },
      {
        "date": "2019-06-20T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-005462"
      },
      {
        "date": "2019-06-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201906-558"
      },
      {
        "date": "2019-06-12T15:29:00.910000",
        "db": "NVD",
        "id": "CVE-2019-3947"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-08-24T00:00:00",
        "db": "VULMON",
        "id": "CVE-2019-3947"
      },
      {
        "date": "2019-06-11T00:00:00",
        "db": "BID",
        "id": "108740"
      },
      {
        "date": "2019-06-20T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-005462"
      },
      {
        "date": "2020-08-25T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201906-558"
      },
      {
        "date": "2024-11-21T04:42:55.407000",
        "db": "NVD",
        "id": "CVE-2019-3947"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-558"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Fuji Electric V-Server Vulnerabilities related to certificate and password management",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005462"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "trust management problem",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-558"
      }
    ],
    "trust": 0.6
  }
}

var-201809-0152
Vulnerability from variot

Fuji Electric V-Server 4.0.3.0 and prior, A heap-based buffer overflow vulnerability has been identified, which may allow remote code execution. Fuji Electric V-Server Contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of a VPR file. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute code under the context of the process. Fuji Electric V-Server VPR is a data collection software from Fuji Electric of Japan. Fuji Electric V-Server is prone to multiple security vulnerabilities: 1. A use-after-free vulnerability 2. Multiple untrusted pointer dereference remote code-execution vulnerabilities 3. Multiple out-of-bounds write vulnerabilities 5. An integer underflow vulnerability 6. An out-of-bounds read vulnerability 7. V-Server 4.0.3.0 and prior are vulnerable

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201809-0152",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "v-server",
        "scope": null,
        "trust": 1.4,
        "vendor": "fuji electric",
        "version": null
      },
      {
        "model": "v-server",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "4.0.3.0"
      },
      {
        "model": "v-server",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "fuji electric",
        "version": "4.0.3.0"
      },
      {
        "model": "electric v-server vpr",
        "scope": "lte",
        "trust": 0.6,
        "vendor": "fuji",
        "version": "\u003c=4.0.3.0"
      },
      {
        "model": "v-server",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "fujielectric",
        "version": "4.0.3.0"
      },
      {
        "model": "electric v-server",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "4.0.3.0"
      },
      {
        "model": "electric v-server",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "4.0.1.0"
      },
      {
        "model": "electric v-server",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "4.0.0.0"
      },
      {
        "model": "electric v-server",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "3.3.22.0"
      },
      {
        "model": "electric v-server",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "4.0.4.0"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "v server",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2fd1b22-39ab-11e9-970b-000c29342cb1"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1017"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1013"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20754"
      },
      {
        "db": "BID",
        "id": "105341"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010415"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-578"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14813"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:fujielectric:v-server",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010415"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Steven Seeley (mr_me) of Source Incite",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-18-1017"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1013"
      }
    ],
    "trust": 1.4
  },
  "cve": "CVE-2018-14813",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-14813",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "ZDI",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CVE-2018-14813",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "MEDIUM",
            "trust": 1.4,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2018-20754",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "e2fd1b22-39ab-11e9-970b-000c29342cb1",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "VHN-125010",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-14813",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2018-14813",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "ZDI",
            "id": "CVE-2018-14813",
            "trust": 1.4,
            "value": "MEDIUM"
          },
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-14813",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-14813",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2018-20754",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201809-578",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "IVD",
            "id": "e2fd1b22-39ab-11e9-970b-000c29342cb1",
            "trust": 0.2,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-125010",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2fd1b22-39ab-11e9-970b-000c29342cb1"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1017"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1013"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20754"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125010"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010415"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-578"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14813"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Fuji Electric V-Server 4.0.3.0 and prior, A heap-based buffer overflow vulnerability has been identified, which may allow remote code execution. Fuji Electric V-Server Contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of a VPR file. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute code under the context of the process. Fuji Electric V-Server VPR is a data collection software from Fuji Electric of Japan. Fuji Electric V-Server is prone to multiple security vulnerabilities:\n1. A use-after-free vulnerability\n2. Multiple untrusted pointer dereference remote code-execution vulnerabilities\n3. Multiple out-of-bounds write vulnerabilities\n5. An integer underflow vulnerability\n6. An out-of-bounds read vulnerability\n7. \nV-Server 4.0.3.0 and prior are vulnerable",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-14813"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010415"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1017"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1013"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20754"
      },
      {
        "db": "BID",
        "id": "105341"
      },
      {
        "db": "IVD",
        "id": "e2fd1b22-39ab-11e9-970b-000c29342cb1"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125010"
      }
    ],
    "trust": 3.96
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-14813",
        "trust": 5.0
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-18-254-01",
        "trust": 2.8
      },
      {
        "db": "BID",
        "id": "105341",
        "trust": 2.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-578",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20754",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010415",
        "trust": 0.8
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-5883",
        "trust": 0.7
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1017",
        "trust": 0.7
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-5879",
        "trust": 0.7
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1013",
        "trust": 0.7
      },
      {
        "db": "IVD",
        "id": "E2FD1B22-39AB-11E9-970B-000C29342CB1",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-125010",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2fd1b22-39ab-11e9-970b-000c29342cb1"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1017"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1013"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20754"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125010"
      },
      {
        "db": "BID",
        "id": "105341"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010415"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-578"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14813"
      }
    ]
  },
  "id": "VAR-201809-0152",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "e2fd1b22-39ab-11e9-970b-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20754"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125010"
      }
    ],
    "trust": 1.77058824
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2fd1b22-39ab-11e9-970b-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20754"
      }
    ]
  },
  "last_update_date": "2024-11-23T21:38:23.999000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Fuji Electric has issued an update to correct this vulnerability.",
        "trust": 1.4,
        "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
      },
      {
        "title": "\u30c8\u30c3\u30d7\u30da\u30fc\u30b8",
        "trust": 0.8,
        "url": "https://www.fujielectric.co.jp/"
      },
      {
        "title": "Patch for Fuji Electric V-Server Buffer Overflow Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/142229"
      },
      {
        "title": "Fuji Electric V-Server VPR Buffer error vulnerability fix",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=84845"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-18-1017"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1013"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20754"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010415"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-578"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-122",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-119",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-125010"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010415"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14813"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 4.2,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-254-01"
      },
      {
        "trust": 2.3,
        "url": "http://www.securityfocus.com/bid/105341"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14813"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-14813"
      },
      {
        "trust": 0.3,
        "url": "http://www.fujielectric.com/"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-18-1017"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1013"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20754"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125010"
      },
      {
        "db": "BID",
        "id": "105341"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010415"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-578"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14813"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "e2fd1b22-39ab-11e9-970b-000c29342cb1"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1017"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1013"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20754"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125010"
      },
      {
        "db": "BID",
        "id": "105341"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010415"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-578"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14813"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-10-12T00:00:00",
        "db": "IVD",
        "id": "e2fd1b22-39ab-11e9-970b-000c29342cb1"
      },
      {
        "date": "2018-09-12T00:00:00",
        "db": "ZDI",
        "id": "ZDI-18-1017"
      },
      {
        "date": "2018-09-12T00:00:00",
        "db": "ZDI",
        "id": "ZDI-18-1013"
      },
      {
        "date": "2018-10-12T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-20754"
      },
      {
        "date": "2018-09-26T00:00:00",
        "db": "VULHUB",
        "id": "VHN-125010"
      },
      {
        "date": "2018-09-11T00:00:00",
        "db": "BID",
        "id": "105341"
      },
      {
        "date": "2018-12-13T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-010415"
      },
      {
        "date": "2018-09-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201809-578"
      },
      {
        "date": "2018-09-26T20:29:00.510000",
        "db": "NVD",
        "id": "CVE-2018-14813"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-09-12T00:00:00",
        "db": "ZDI",
        "id": "ZDI-18-1017"
      },
      {
        "date": "2018-09-12T00:00:00",
        "db": "ZDI",
        "id": "ZDI-18-1013"
      },
      {
        "date": "2018-10-12T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-20754"
      },
      {
        "date": "2020-08-28T00:00:00",
        "db": "VULHUB",
        "id": "VHN-125010"
      },
      {
        "date": "2018-09-11T00:00:00",
        "db": "BID",
        "id": "105341"
      },
      {
        "date": "2018-12-13T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-010415"
      },
      {
        "date": "2019-10-17T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201809-578"
      },
      {
        "date": "2024-11-21T03:49:50.993000",
        "db": "NVD",
        "id": "CVE-2018-14813"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-578"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Fuji Electric V-Server Buffer Overflow Vulnerability",
    "sources": [
      {
        "db": "IVD",
        "id": "e2fd1b22-39ab-11e9-970b-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20754"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Buffer error",
    "sources": [
      {
        "db": "IVD",
        "id": "e2fd1b22-39ab-11e9-970b-000c29342cb1"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-578"
      }
    ],
    "trust": 0.8
  }
}

var-201911-1048
Vulnerability from variot

In Fuji Electric V-Server 4.0.6 and prior, several heap-based buffer overflows have been identified, which may allow an attacker to remotely execute arbitrary code. Fuji Electric V-Server Contains an out-of-bounds vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the processing of VPR files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Fuji Electric V-Server is a set of software used by Fuji Electric to collect and manage real-time field data.

A buffer overflow vulnerability exists in Fuji Electric V-Server 4.0.6 and earlier. This vulnerability is caused by a network system or product performing an operation on memory that does not properly validate data boundaries, causing an error to be performed on other associated memory locations. Read and write operations that an attacker can exploit to cause a buffer overflow or heap overflow

Show details on source website


{
  "affected_products": {
    "_id": null,
    "data": [
      {
        "_id": null,
        "model": "v-server",
        "scope": null,
        "trust": 3.5,
        "vendor": "fuji electric",
        "version": null
      },
      {
        "_id": null,
        "model": "v-server",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "4.0.6"
      },
      {
        "_id": null,
        "model": "v-server",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "fuji electric",
        "version": "4.0.6"
      },
      {
        "_id": null,
        "model": "electric v-server",
        "scope": "lte",
        "trust": 0.6,
        "vendor": "fuji",
        "version": "\u003c=4.0.6"
      },
      {
        "_id": null,
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "v server",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "c161eb5b-3004-48c3-93e9-62ac80f32cd5"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-968"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-970"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-967"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-969"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-971"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-41427"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-012000"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-18240"
      }
    ]
  },
  "configurations": {
    "_id": null,
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:fujielectric:v-server",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-012000"
      }
    ]
  },
  "credits": {
    "_id": null,
    "data": "kimiya of 9SG",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-19-968"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-970"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-967"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-969"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-971"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-426"
      }
    ],
    "trust": 4.1
  },
  "cve": "CVE-2019-18240",
  "cvss": {
    "_id": null,
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2019-18240",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-41427",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "c161eb5b-3004-48c3-93e9-62ac80f32cd5",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.9 [IVD]"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "ZDI",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2019-18240",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 3.5,
            "userInteraction": "REQUIRED",
            "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2019-18240",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2019-18240",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "ZDI",
            "id": "CVE-2019-18240",
            "trust": 3.5,
            "value": "HIGH"
          },
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2019-18240",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2019-18240",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-41427",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201911-426",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "IVD",
            "id": "c161eb5b-3004-48c3-93e9-62ac80f32cd5",
            "trust": 0.2,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "c161eb5b-3004-48c3-93e9-62ac80f32cd5"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-968"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-970"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-967"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-969"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-971"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-41427"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-012000"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-426"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-18240"
      }
    ]
  },
  "description": {
    "_id": null,
    "data": "In Fuji Electric V-Server 4.0.6 and prior, several heap-based buffer overflows have been identified, which may allow an attacker to remotely execute arbitrary code. Fuji Electric V-Server Contains an out-of-bounds vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state.  User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the processing of VPR files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer.  An attacker can leverage this vulnerability to execute code in the context of the current process. Fuji Electric V-Server is a set of software used by Fuji Electric to collect and manage real-time field data. \n\nA buffer overflow vulnerability exists in Fuji Electric V-Server 4.0.6 and earlier. This vulnerability is caused by a network system or product performing an operation on memory that does not properly validate data boundaries, causing an error to be performed on other associated memory locations. Read and write operations that an attacker can exploit to cause a buffer overflow or heap overflow",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-18240"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-012000"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-968"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-970"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-967"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-969"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-971"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-41427"
      },
      {
        "db": "IVD",
        "id": "c161eb5b-3004-48c3-93e9-62ac80f32cd5"
      }
    ],
    "trust": 5.49
  },
  "external_ids": {
    "_id": null,
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2019-18240",
        "trust": 6.7
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-19-311-02",
        "trust": 3.0
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-971",
        "trust": 1.3
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2019.4210",
        "trust": 1.2
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-41427",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-426",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-012000",
        "trust": 0.8
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-8848",
        "trust": 0.7
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-968",
        "trust": 0.7
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-8931",
        "trust": 0.7
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-970",
        "trust": 0.7
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-8844",
        "trust": 0.7
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-967",
        "trust": 0.7
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-8904",
        "trust": 0.7
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-969",
        "trust": 0.7
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-8932",
        "trust": 0.7
      },
      {
        "db": "IVD",
        "id": "C161EB5B-3004-48C3-93E9-62AC80F32CD5",
        "trust": 0.2
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "c161eb5b-3004-48c3-93e9-62ac80f32cd5"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-968"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-970"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-967"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-969"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-971"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-41427"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-012000"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-426"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-18240"
      }
    ]
  },
  "id": "VAR-201911-1048",
  "iot": {
    "_id": null,
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "c161eb5b-3004-48c3-93e9-62ac80f32cd5"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-41427"
      }
    ],
    "trust": 1.67058824
  },
  "iot_taxonomy": {
    "_id": null,
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "c161eb5b-3004-48c3-93e9-62ac80f32cd5"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-41427"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:29:50.428000Z",
  "patch": {
    "_id": null,
    "data": [
      {
        "title": "Fuji Electric has issued an update to correct this vulnerability.",
        "trust": 3.5,
        "url": "https://www.us-cert.gov/ics/advisories/icsa-19-311-02"
      },
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.fujielectric.com/index.html"
      },
      {
        "title": "Patch for Fuji Electric V-Server Buffer Overflow Vulnerability (CNVD-2019-41427)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/191105"
      },
      {
        "title": "Fuji Electric V-Server Buffer error vulnerability fix",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=103039"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-19-968"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-970"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-967"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-969"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-971"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-41427"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-012000"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-426"
      }
    ]
  },
  "problemtype_data": {
    "_id": null,
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.8
      },
      {
        "problemtype": "CWE-122",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-012000"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-18240"
      }
    ]
  },
  "references": {
    "_id": null,
    "data": [
      {
        "trust": 7.1,
        "url": "https://www.us-cert.gov/ics/advisories/icsa-19-311-02"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-18240"
      },
      {
        "trust": 1.2,
        "url": "https://www.auscert.org.au/bulletins/esb-2019.4210/"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-18240"
      },
      {
        "trust": 0.6,
        "url": "https://www.zerodayinitiative.com/advisories/zdi-19-971/"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-19-968"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-970"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-967"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-969"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-971"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-41427"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-012000"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-426"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-18240"
      }
    ]
  },
  "sources": {
    "_id": null,
    "data": [
      {
        "db": "IVD",
        "id": "c161eb5b-3004-48c3-93e9-62ac80f32cd5",
        "ident": null
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-968",
        "ident": null
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-970",
        "ident": null
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-967",
        "ident": null
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-969",
        "ident": null
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-971",
        "ident": null
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-41427",
        "ident": null
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-012000",
        "ident": null
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-426",
        "ident": null
      },
      {
        "db": "NVD",
        "id": "CVE-2019-18240",
        "ident": null
      }
    ]
  },
  "sources_release_date": {
    "_id": null,
    "data": [
      {
        "date": "2019-11-20T00:00:00",
        "db": "IVD",
        "id": "c161eb5b-3004-48c3-93e9-62ac80f32cd5",
        "ident": null
      },
      {
        "date": "2019-11-11T00:00:00",
        "db": "ZDI",
        "id": "ZDI-19-968",
        "ident": null
      },
      {
        "date": "2019-11-11T00:00:00",
        "db": "ZDI",
        "id": "ZDI-19-970",
        "ident": null
      },
      {
        "date": "2019-11-11T00:00:00",
        "db": "ZDI",
        "id": "ZDI-19-967",
        "ident": null
      },
      {
        "date": "2019-11-11T00:00:00",
        "db": "ZDI",
        "id": "ZDI-19-969",
        "ident": null
      },
      {
        "date": "2019-11-11T00:00:00",
        "db": "ZDI",
        "id": "ZDI-19-971",
        "ident": null
      },
      {
        "date": "2019-11-20T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-41427",
        "ident": null
      },
      {
        "date": "2019-11-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-012000",
        "ident": null
      },
      {
        "date": "2019-11-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201911-426",
        "ident": null
      },
      {
        "date": "2019-11-13T23:15:11.433000",
        "db": "NVD",
        "id": "CVE-2019-18240",
        "ident": null
      }
    ]
  },
  "sources_update_date": {
    "_id": null,
    "data": [
      {
        "date": "2019-11-11T00:00:00",
        "db": "ZDI",
        "id": "ZDI-19-968",
        "ident": null
      },
      {
        "date": "2019-11-11T00:00:00",
        "db": "ZDI",
        "id": "ZDI-19-970",
        "ident": null
      },
      {
        "date": "2019-11-11T00:00:00",
        "db": "ZDI",
        "id": "ZDI-19-967",
        "ident": null
      },
      {
        "date": "2019-11-11T00:00:00",
        "db": "ZDI",
        "id": "ZDI-19-969",
        "ident": null
      },
      {
        "date": "2019-11-11T00:00:00",
        "db": "ZDI",
        "id": "ZDI-19-971",
        "ident": null
      },
      {
        "date": "2019-11-20T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-41427",
        "ident": null
      },
      {
        "date": "2019-11-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-012000",
        "ident": null
      },
      {
        "date": "2020-07-10T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201911-426",
        "ident": null
      },
      {
        "date": "2024-11-21T04:32:54.107000",
        "db": "NVD",
        "id": "CVE-2019-18240",
        "ident": null
      }
    ]
  },
  "threat_type": {
    "_id": null,
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-426"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "_id": null,
    "data": "Fuji Electric V-Server VPR File Parsing Heap-based Buffer Overflow Remote Code Execution Vulnerability",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-19-968"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-970"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-967"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-969"
      },
      {
        "db": "ZDI",
        "id": "ZDI-19-971"
      }
    ],
    "trust": 3.5
  },
  "type": {
    "_id": null,
    "data": "Buffer error",
    "sources": [
      {
        "db": "IVD",
        "id": "c161eb5b-3004-48c3-93e9-62ac80f32cd5"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-426"
      }
    ],
    "trust": 0.8
  }
}

var-201906-0327
Vulnerability from variot

Fuji Electric V-Server before 6.0.33.0 is vulnerable to denial of service via a crafted UDP message sent to port 8005. An unauthenticated, remote attacker can crash vserver.exe due to an integer overflow in the UDP message handling logic. Fuji Electric V-Server Contains vulnerabilities related to certificate and password management.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Fuji Electric V-Server is a set of software used by Fuji Electric to collect and manage real-time field data. An input validation error vulnerability exists in Fuji Electric V-Server prior to 6.0.33.0. The vulnerability stems from a network system or product that does not properly validate the input data. A remote denial-of-service vulnerability 2. An information disclosure vulnerability An attacker can exploit these issues to cause a denial-of-service condition or obtain sensitive information that may lead to further attacks . Versions prior to V-SFT 6.0.33.0 are vulnerable

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201906-0327",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "v-server",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "fuji electric",
        "version": "6.0.33.0"
      },
      {
        "model": "v-server",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "6.0.33.0"
      },
      {
        "model": "electric v-server",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "fuji",
        "version": "6.0.33.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.9.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.8.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.7.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.6.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.5.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.4.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.32.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.31.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.30.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.3.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.29.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.28.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.27.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.26.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.25.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.24.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.23.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.22.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.21.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.20.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.2.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.19.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.18.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.17.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.16.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.15.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.14.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.13.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.12.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.11.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.10.0"
      },
      {
        "model": "electric monitouch v-sft",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "6.0.33.0"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "v server",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "b858cd6c-22d1-49a4-a77a-e989933c9367"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-25688"
      },
      {
        "db": "BID",
        "id": "108740"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005490"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005462"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-3946"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:fujielectric:v-server",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005490"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenable",
    "sources": [
      {
        "db": "BID",
        "id": "108740"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-559"
      }
    ],
    "trust": 0.9
  },
  "cve": "CVE-2019-3946",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2019-3946",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.9,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 5.0,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "CVE-2019-3946",
            "impactScore": null,
            "integrityImpact": "None",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-25688",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "b858cd6c-22d1-49a4-a77a-e989933c9367",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.9 [IVD]"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2019-3946",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2019-3946",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2019-3946",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2019-3946",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "NVD",
            "id": "CVE-2019-3946",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-25688",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201906-559",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "IVD",
            "id": "b858cd6c-22d1-49a4-a77a-e989933c9367",
            "trust": 0.2,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2019-3946",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "b858cd6c-22d1-49a4-a77a-e989933c9367"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-25688"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-3946"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005490"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005462"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-559"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-3946"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Fuji Electric V-Server before 6.0.33.0 is vulnerable to denial of service via a crafted UDP message sent to port 8005. An unauthenticated, remote attacker can crash vserver.exe due to an integer overflow in the UDP message handling logic. Fuji Electric V-Server Contains vulnerabilities related to certificate and password management.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Fuji Electric V-Server is a set of software used by Fuji Electric to collect and manage real-time field data. An input validation error vulnerability exists in Fuji Electric V-Server prior to 6.0.33.0. The vulnerability stems from a network system or product that does not properly validate the input data. A remote denial-of-service vulnerability\n2. An information disclosure vulnerability\nAn attacker can exploit these issues to cause a denial-of-service condition or obtain sensitive information that may lead to further attacks . \nVersions prior to V-SFT 6.0.33.0 are vulnerable",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-3946"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005490"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005462"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-25688"
      },
      {
        "db": "BID",
        "id": "108740"
      },
      {
        "db": "IVD",
        "id": "b858cd6c-22d1-49a4-a77a-e989933c9367"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-3946"
      }
    ],
    "trust": 3.42
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2019-3946",
        "trust": 4.4
      },
      {
        "db": "TENABLE",
        "id": "TRA-2019-27",
        "trust": 4.2
      },
      {
        "db": "BID",
        "id": "108740",
        "trust": 2.0
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-25688",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-559",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005490",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005462",
        "trust": 0.8
      },
      {
        "db": "IVD",
        "id": "B858CD6C-22D1-49A4-A77A-E989933C9367",
        "trust": 0.2
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-3946",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "b858cd6c-22d1-49a4-a77a-e989933c9367"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-25688"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-3946"
      },
      {
        "db": "BID",
        "id": "108740"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005490"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005462"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-559"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-3946"
      }
    ]
  },
  "id": "VAR-201906-0327",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "b858cd6c-22d1-49a4-a77a-e989933c9367"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-25688"
      }
    ],
    "trust": 1.56029412
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "b858cd6c-22d1-49a4-a77a-e989933c9367"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-25688"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:33:54.410000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "V-Server",
        "trust": 1.6,
        "url": "https://monitouch.fujielectric.com/site/tellus-e/tellus03-01.html"
      },
      {
        "title": "Fuji Electric V-Server enters a patch to verify the error vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/172789"
      },
      {
        "title": "Fuji Electric V-Server Enter the fix for the verification error vulnerability",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=93791"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-25688"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005490"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005462"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-559"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-190",
        "trust": 1.8
      },
      {
        "problemtype": "CWE-255",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005490"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005462"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-3946"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 4.2,
        "url": "https://www.tenable.com/security/research/tra-2019-27"
      },
      {
        "trust": 1.8,
        "url": "http://www.securityfocus.com/bid/108740"
      },
      {
        "trust": 0.9,
        "url": "http://www.fujielectric.com/"
      },
      {
        "trust": 0.9,
        "url": "https://monitouch.fujielectric.com/site/support-e/more-index-t.html"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-3946"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-3946"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-3947"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-3947"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/190.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-25688"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-3946"
      },
      {
        "db": "BID",
        "id": "108740"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005490"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005462"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-559"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-3946"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "b858cd6c-22d1-49a4-a77a-e989933c9367"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-25688"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-3946"
      },
      {
        "db": "BID",
        "id": "108740"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005490"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-005462"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-559"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-3946"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-08-02T00:00:00",
        "db": "IVD",
        "id": "b858cd6c-22d1-49a4-a77a-e989933c9367"
      },
      {
        "date": "2019-08-02T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-25688"
      },
      {
        "date": "2019-06-12T00:00:00",
        "db": "VULMON",
        "id": "CVE-2019-3946"
      },
      {
        "date": "2019-06-11T00:00:00",
        "db": "BID",
        "id": "108740"
      },
      {
        "date": "2019-06-20T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-005490"
      },
      {
        "date": "2019-06-20T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-005462"
      },
      {
        "date": "2019-06-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201906-559"
      },
      {
        "date": "2019-06-12T15:29:00.863000",
        "db": "NVD",
        "id": "CVE-2019-3946"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-08-02T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-25688"
      },
      {
        "date": "2019-06-14T00:00:00",
        "db": "VULMON",
        "id": "CVE-2019-3946"
      },
      {
        "date": "2019-06-11T00:00:00",
        "db": "BID",
        "id": "108740"
      },
      {
        "date": "2019-06-20T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-005490"
      },
      {
        "date": "2019-06-20T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-005462"
      },
      {
        "date": "2019-06-17T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201906-559"
      },
      {
        "date": "2024-11-21T04:42:55.280000",
        "db": "NVD",
        "id": "CVE-2019-3946"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-559"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Fuji Electric V-Server Input validation error vulnerability",
    "sources": [
      {
        "db": "IVD",
        "id": "b858cd6c-22d1-49a4-a77a-e989933c9367"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-25688"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-559"
      }
    ],
    "trust": 1.4
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Input validation error",
    "sources": [
      {
        "db": "IVD",
        "id": "b858cd6c-22d1-49a4-a77a-e989933c9367"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-559"
      }
    ],
    "trust": 0.8
  }
}

var-202004-0059
Vulnerability from variot

Fuji Electric V-Server Lite all versions prior to 4.0.9.0 contains a heap based buffer overflow. The buffer allocated to read data, when parsing VPR files, is too small. Provided by Fuji Electric Co., Ltd. V-Server Lite Is an industrial software that collects production information in real time. V-Server Lite To VPR File ( Project file ) Heap-based buffer overflow vulnerability due to too small buffer size allocated when reading (CWE-122) Exists.A remote attacker could elevate privileges and execute arbitrary code. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric V-Server Lite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the processing of VPR files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process

Show details on source website


{
  "affected_products": {
    "_id": null,
    "data": [
      {
        "_id": null,
        "model": "v-server lite",
        "scope": null,
        "trust": 1.4,
        "vendor": "fuji electric",
        "version": null
      },
      {
        "_id": null,
        "model": "v-server",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "4.0.9.0"
      },
      {
        "_id": null,
        "model": "v-server",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "fuji electric",
        "version": "lite 4.0.9.0 \u306e\u5168\u3066"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-20-451"
      },
      {
        "db": "ZDI",
        "id": "ZDI-20-452"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-003280"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-10646"
      }
    ]
  },
  "configurations": {
    "_id": null,
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "4.0.9.0",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-10646"
      }
    ]
  },
  "credits": {
    "_id": null,
    "data": "kimiya",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-20-451"
      },
      {
        "db": "ZDI",
        "id": "ZDI-20-452"
      }
    ],
    "trust": 1.4
  },
  "cve": "CVE-2020-10646",
  "cvss": {
    "_id": null,
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CVE-2020-10646",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": true,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "ZDI",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2020-10646",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.4,
            "userInteraction": "REQUIRED",
            "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2020-10646",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Local",
            "author": "IPA score",
            "availabilityImpact": "High",
            "baseScore": 7.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-003280",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "Required",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "ZDI",
            "id": "CVE-2020-10646",
            "trust": 1.4,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2020-10646",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "IPA",
            "id": "JVNDB-2020-003280",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202004-374",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-20-451"
      },
      {
        "db": "ZDI",
        "id": "ZDI-20-452"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-003280"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202004-374"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-10646"
      }
    ]
  },
  "description": {
    "_id": null,
    "data": "Fuji Electric V-Server Lite all versions prior to 4.0.9.0 contains a heap based buffer overflow. The buffer allocated to read data, when parsing VPR files, is too small. Provided by Fuji Electric Co., Ltd. V-Server Lite Is an industrial software that collects production information in real time. V-Server Lite To VPR File ( Project file ) Heap-based buffer overflow vulnerability due to too small buffer size allocated when reading (CWE-122) Exists.A remote attacker could elevate privileges and execute arbitrary code. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric V-Server Lite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the processing of VPR files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-10646"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-003280"
      },
      {
        "db": "ZDI",
        "id": "ZDI-20-451"
      },
      {
        "db": "ZDI",
        "id": "ZDI-20-452"
      }
    ],
    "trust": 2.88
  },
  "external_ids": {
    "_id": null,
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-10646",
        "trust": 3.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-20-098-04",
        "trust": 2.4
      },
      {
        "db": "ZDI",
        "id": "ZDI-20-452",
        "trust": 1.3
      },
      {
        "db": "JVN",
        "id": "JVNVU98887141",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-003280",
        "trust": 0.8
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-10119",
        "trust": 0.7
      },
      {
        "db": "ZDI",
        "id": "ZDI-20-451",
        "trust": 0.7
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-10120",
        "trust": 0.7
      },
      {
        "db": "NSFOCUS",
        "id": "47584",
        "trust": 0.6
      },
      {
        "db": "NSFOCUS",
        "id": "47741",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2020.1254",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202004-374",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-20-451"
      },
      {
        "db": "ZDI",
        "id": "ZDI-20-452"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-003280"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202004-374"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-10646"
      }
    ]
  },
  "id": "VAR-202004-0059",
  "iot": {
    "_id": null,
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.41666666
  },
  "last_update_date": "2022-05-04T09:21:58.233000Z",
  "patch": {
    "_id": null,
    "data": [
      {
        "title": "Fuji Electric has issued an update to correct this vulnerability.",
        "trust": 1.4,
        "url": "https://www.us-cert.gov/ics/advisories/icsa-20-098-04"
      },
      {
        "title": "Fe Library",
        "trust": 0.8,
        "url": "https://felib.fujielectric.co.jp/download/pod_document.htm?product1_id=p10003\u0026product2_id=p20023\u0026product3_id=p30262\u0026material1_id=m10009\u0026site=global\u0026lang=en"
      },
      {
        "title": "Fuji Electric V-Server Lite Buffer error vulnerability fix",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=115595"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-20-451"
      },
      {
        "db": "ZDI",
        "id": "ZDI-20-452"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-003280"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202004-374"
      }
    ]
  },
  "problemtype_data": {
    "_id": null,
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-122",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-003280"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-10646"
      }
    ]
  },
  "references": {
    "_id": null,
    "data": [
      {
        "trust": 3.8,
        "url": "https://www.us-cert.gov/ics/advisories/icsa-20-098-04"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-10646"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu98887141/index.html"
      },
      {
        "trust": 0.6,
        "url": "http://www.nsfocus.net/vulndb/47741"
      },
      {
        "trust": 0.6,
        "url": "https://www.zerodayinitiative.com/advisories/zdi-20-452/"
      },
      {
        "trust": 0.6,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-10646"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2020.1254/"
      },
      {
        "trust": 0.6,
        "url": "http://www.nsfocus.net/vulndb/47584"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-20-451"
      },
      {
        "db": "ZDI",
        "id": "ZDI-20-452"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-003280"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202004-374"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-10646"
      }
    ]
  },
  "sources": {
    "_id": null,
    "data": [
      {
        "db": "ZDI",
        "id": "ZDI-20-451",
        "ident": null
      },
      {
        "db": "ZDI",
        "id": "ZDI-20-452",
        "ident": null
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-003280",
        "ident": null
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202004-374",
        "ident": null
      },
      {
        "db": "NVD",
        "id": "CVE-2020-10646",
        "ident": null
      }
    ]
  },
  "sources_release_date": {
    "_id": null,
    "data": [
      {
        "date": "2020-04-09T00:00:00",
        "db": "ZDI",
        "id": "ZDI-20-451",
        "ident": null
      },
      {
        "date": "2020-04-09T00:00:00",
        "db": "ZDI",
        "id": "ZDI-20-452",
        "ident": null
      },
      {
        "date": "2020-04-13T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-003280",
        "ident": null
      },
      {
        "date": "2020-04-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202004-374",
        "ident": null
      },
      {
        "date": "2020-04-13T19:15:00",
        "db": "NVD",
        "id": "CVE-2020-10646",
        "ident": null
      }
    ]
  },
  "sources_update_date": {
    "_id": null,
    "data": [
      {
        "date": "2020-04-09T00:00:00",
        "db": "ZDI",
        "id": "ZDI-20-451",
        "ident": null
      },
      {
        "date": "2020-04-09T00:00:00",
        "db": "ZDI",
        "id": "ZDI-20-452",
        "ident": null
      },
      {
        "date": "2020-04-13T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-003280",
        "ident": null
      },
      {
        "date": "2020-08-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202004-374",
        "ident": null
      },
      {
        "date": "2020-04-13T20:11:00",
        "db": "NVD",
        "id": "CVE-2020-10646",
        "ident": null
      }
    ]
  },
  "threat_type": {
    "_id": null,
    "data": "local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202004-374"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "_id": null,
    "data": "Fuji Electric V-Server Lite VPR File Parsing Heap-based Buffer Overflow Remote Code Execution Vulnerability",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-20-451"
      },
      {
        "db": "ZDI",
        "id": "ZDI-20-452"
      }
    ],
    "trust": 1.4
  },
  "type": {
    "_id": null,
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202004-374"
      }
    ],
    "trust": 0.6
  }
}

var-201809-0153
Vulnerability from variot

Fuji Electric V-Server 4.0.3.0 and prior, Several out-of-bounds write vulnerabilities have been identified, which may allow remote code execution. Fuji Electric V-Server Contains an out-of-bounds vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of a VPR file. The issue results from the lack of proper validation of user-supplied data, which can result in a type confusion condition. An attacker can leverage this vulnerability to execute code under the context of the V-Server process. Fuji Electric V-server is Fuji Electric Co., Ltd. to collect and manage real-time field data. Real-time monitoring of the plant from a remote location to solve problems without having to visit the site. A use-after-free vulnerability 2. Multiple untrusted pointer dereference remote code-execution vulnerabilities 3. A heap-based buffer overflow vulnerability 4. An integer underflow vulnerability 6. V-Server 4.0.3.0 and prior are vulnerable

Show details on source website


{
  "affected_products": {
    "_id": null,
    "data": [
      {
        "_id": null,
        "model": "v-server",
        "scope": null,
        "trust": 1.4,
        "vendor": "fuji electric",
        "version": null
      },
      {
        "_id": null,
        "model": "v-server",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "4.0.3.0"
      },
      {
        "_id": null,
        "model": "v-server",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "fuji electric",
        "version": "4.0.3.0"
      },
      {
        "_id": null,
        "model": "electric v-server vpr",
        "scope": "lte",
        "trust": 0.6,
        "vendor": "fuji",
        "version": "\u003c=4.0.3.0"
      },
      {
        "_id": null,
        "model": "v-server",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "fujielectric",
        "version": "4.0.3.0"
      },
      {
        "_id": null,
        "model": "electric v-server",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "4.0.3.0"
      },
      {
        "_id": null,
        "model": "electric v-server",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "4.0.1.0"
      },
      {
        "_id": null,
        "model": "electric v-server",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "4.0.0.0"
      },
      {
        "_id": null,
        "model": "electric v-server",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "3.3.22.0"
      },
      {
        "_id": null,
        "model": "electric v-server",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "4.0.4.0"
      },
      {
        "_id": null,
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "v server",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2fd6941-39ab-11e9-aeed-000c29342cb1"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1015"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1016"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20785"
      },
      {
        "db": "BID",
        "id": "105341"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010416"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-579"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14815"
      }
    ]
  },
  "configurations": {
    "_id": null,
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:fujielectric:v-server",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010416"
      }
    ]
  },
  "credits": {
    "_id": null,
    "data": "Steven Seeley (mr_me) of Source Incite",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-18-1015"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1016"
      }
    ],
    "trust": 1.4
  },
  "cve": "CVE-2018-14815",
  "cvss": {
    "_id": null,
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-14815",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "ZDI",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CVE-2018-14815",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "MEDIUM",
            "trust": 1.4,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2018-20785",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "e2fd6941-39ab-11e9-aeed-000c29342cb1",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "VHN-125012",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-14815",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "ZDI",
            "id": "CVE-2018-14815",
            "trust": 1.4,
            "value": "MEDIUM"
          },
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-14815",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-14815",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2018-20785",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201809-579",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "IVD",
            "id": "e2fd6941-39ab-11e9-aeed-000c29342cb1",
            "trust": 0.2,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-125012",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2fd6941-39ab-11e9-aeed-000c29342cb1"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1015"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1016"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20785"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125012"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010416"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-579"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14815"
      }
    ]
  },
  "description": {
    "_id": null,
    "data": "Fuji Electric V-Server 4.0.3.0 and prior, Several out-of-bounds write vulnerabilities have been identified, which may allow remote code execution. Fuji Electric V-Server Contains an out-of-bounds vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of a VPR file. The issue results from the lack of proper validation of user-supplied data, which can result in a type confusion condition. An attacker can leverage this vulnerability to execute code under the context of the V-Server process. Fuji Electric V-server is Fuji Electric Co., Ltd. to collect and manage real-time field data. Real-time monitoring of the plant from a remote location to solve problems without having to visit the site. A use-after-free vulnerability\n2. Multiple untrusted pointer dereference remote code-execution vulnerabilities\n3. A heap-based buffer overflow vulnerability\n4. An integer underflow vulnerability\n6. \nV-Server 4.0.3.0 and prior are vulnerable",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-14815"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010416"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1015"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1016"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20785"
      },
      {
        "db": "BID",
        "id": "105341"
      },
      {
        "db": "IVD",
        "id": "e2fd6941-39ab-11e9-aeed-000c29342cb1"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125012"
      }
    ],
    "trust": 3.96
  },
  "external_ids": {
    "_id": null,
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-14815",
        "trust": 5.0
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-18-254-01",
        "trust": 2.8
      },
      {
        "db": "BID",
        "id": "105341",
        "trust": 2.0
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-579",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20785",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010416",
        "trust": 0.8
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-5881",
        "trust": 0.7
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1015",
        "trust": 0.7
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-5882",
        "trust": 0.7
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1016",
        "trust": 0.7
      },
      {
        "db": "IVD",
        "id": "E2FD6941-39AB-11E9-AEED-000C29342CB1",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-125012",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2fd6941-39ab-11e9-aeed-000c29342cb1"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1015"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1016"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20785"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125012"
      },
      {
        "db": "BID",
        "id": "105341"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010416"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-579"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14815"
      }
    ]
  },
  "id": "VAR-201809-0153",
  "iot": {
    "_id": null,
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "e2fd6941-39ab-11e9-aeed-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20785"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125012"
      }
    ],
    "trust": 1.77058824
  },
  "iot_taxonomy": {
    "_id": null,
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2fd6941-39ab-11e9-aeed-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20785"
      }
    ]
  },
  "last_update_date": "2024-11-23T21:38:24.091000Z",
  "patch": {
    "_id": null,
    "data": [
      {
        "title": "Fuji Electric has issued an update to correct this vulnerability.",
        "trust": 1.4,
        "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
      },
      {
        "title": "\u30c8\u30c3\u30d7\u30da\u30fc\u30b8",
        "trust": 0.8,
        "url": "https://www.fujielectric.co.jp/"
      },
      {
        "title": "Fuji Electric V-Server patch for out-of-bounds write vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/142221"
      },
      {
        "title": "Fuji Electric V-Server VPR Buffer error vulnerability fix",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=84846"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-18-1015"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1016"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20785"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010416"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-579"
      }
    ]
  },
  "problemtype_data": {
    "_id": null,
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-125012"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010416"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14815"
      }
    ]
  },
  "references": {
    "_id": null,
    "data": [
      {
        "trust": 4.2,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-254-01"
      },
      {
        "trust": 1.7,
        "url": "http://www.securityfocus.com/bid/105341"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14815"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-14815"
      },
      {
        "trust": 0.3,
        "url": "http://www.fujielectric.com/"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-18-1015"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1016"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20785"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125012"
      },
      {
        "db": "BID",
        "id": "105341"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010416"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-579"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14815"
      }
    ]
  },
  "sources": {
    "_id": null,
    "data": [
      {
        "db": "IVD",
        "id": "e2fd6941-39ab-11e9-aeed-000c29342cb1",
        "ident": null
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1015",
        "ident": null
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1016",
        "ident": null
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20785",
        "ident": null
      },
      {
        "db": "VULHUB",
        "id": "VHN-125012",
        "ident": null
      },
      {
        "db": "BID",
        "id": "105341",
        "ident": null
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010416",
        "ident": null
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-579",
        "ident": null
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14815",
        "ident": null
      }
    ]
  },
  "sources_release_date": {
    "_id": null,
    "data": [
      {
        "date": "2018-10-12T00:00:00",
        "db": "IVD",
        "id": "e2fd6941-39ab-11e9-aeed-000c29342cb1",
        "ident": null
      },
      {
        "date": "2018-09-12T00:00:00",
        "db": "ZDI",
        "id": "ZDI-18-1015",
        "ident": null
      },
      {
        "date": "2018-09-12T00:00:00",
        "db": "ZDI",
        "id": "ZDI-18-1016",
        "ident": null
      },
      {
        "date": "2018-10-12T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-20785",
        "ident": null
      },
      {
        "date": "2018-09-26T00:00:00",
        "db": "VULHUB",
        "id": "VHN-125012",
        "ident": null
      },
      {
        "date": "2018-09-11T00:00:00",
        "db": "BID",
        "id": "105341",
        "ident": null
      },
      {
        "date": "2018-12-13T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-010416",
        "ident": null
      },
      {
        "date": "2018-09-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201809-579",
        "ident": null
      },
      {
        "date": "2018-09-26T20:29:00.620000",
        "db": "NVD",
        "id": "CVE-2018-14815",
        "ident": null
      }
    ]
  },
  "sources_update_date": {
    "_id": null,
    "data": [
      {
        "date": "2018-09-12T00:00:00",
        "db": "ZDI",
        "id": "ZDI-18-1015",
        "ident": null
      },
      {
        "date": "2018-09-12T00:00:00",
        "db": "ZDI",
        "id": "ZDI-18-1016",
        "ident": null
      },
      {
        "date": "2018-10-12T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-20785",
        "ident": null
      },
      {
        "date": "2018-11-16T00:00:00",
        "db": "VULHUB",
        "id": "VHN-125012",
        "ident": null
      },
      {
        "date": "2018-09-11T00:00:00",
        "db": "BID",
        "id": "105341",
        "ident": null
      },
      {
        "date": "2018-12-13T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-010416",
        "ident": null
      },
      {
        "date": "2018-09-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201809-579",
        "ident": null
      },
      {
        "date": "2024-11-21T03:49:51.263000",
        "db": "NVD",
        "id": "CVE-2018-14815",
        "ident": null
      }
    ]
  },
  "threat_type": {
    "_id": null,
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-579"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "_id": null,
    "data": "Fuji Electric V-Server Vulnerable to out-of-bounds writing",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010416"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "_id": null,
    "data": "Buffer error",
    "sources": [
      {
        "db": "IVD",
        "id": "e2fd6941-39ab-11e9-aeed-000c29342cb1"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-579"
      }
    ],
    "trust": 0.8
  }
}

var-202101-1103
Vulnerability from variot

Multiple stack-based buffer overflow issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0). V-Simulator and V-Server Lite Is vulnerable to an out-of-bounds write.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric V-Server Lite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of VPR files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite are both products of Fuji Electric, Japan. The software can collect information about PLCs, temperature controllers, inverters and other equipment

Show details on source website


{
  "affected_products": {
    "_id": null,
    "data": [
      {
        "_id": null,
        "model": "v-server",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "4.0.10.0"
      },
      {
        "_id": null,
        "model": "v-simulator",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "4.0.10.0"
      },
      {
        "_id": null,
        "model": "v-simulator",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u5bcc\u58eb\u96fb\u6a5f",
        "version": "lite 4.0.10.0"
      },
      {
        "_id": null,
        "model": "v-server",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u5bcc\u58eb\u96fb\u6a5f",
        "version": null
      },
      {
        "_id": null,
        "model": "v-server lite",
        "scope": null,
        "trust": 0.7,
        "vendor": "fuji electric",
        "version": null
      },
      {
        "_id": null,
        "model": "electric tellus lite v-simulator",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "fuji",
        "version": "4.0.10.0"
      },
      {
        "_id": null,
        "model": "electric v-server lite",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "fuji",
        "version": "4.0.10.0"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-097"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17711"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002819"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22637"
      }
    ]
  },
  "credits": {
    "_id": null,
    "data": "Anonymous",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-097"
      }
    ],
    "trust": 0.7
  },
  "cve": "CVE-2021-22637",
  "cvss": {
    "_id": null,
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CVE-2021-22637",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.9,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CNVD-2021-17711",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2021-22637",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Local",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2021-22637",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "Required",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "ZDI",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2021-22637",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 0.7,
            "userInteraction": "REQUIRED",
            "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2021-22637",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2021-22637",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "ZDI",
            "id": "CVE-2021-22637",
            "trust": 0.7,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2021-17711",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202101-2406",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2021-22637",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-097"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17711"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22637"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002819"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2406"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22637"
      }
    ]
  },
  "description": {
    "_id": null,
    "data": "Multiple stack-based buffer overflow issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0). V-Simulator and V-Server Lite Is vulnerable to an out-of-bounds write.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric V-Server Lite.  User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of VPR files.  The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite are both products of Fuji Electric, Japan. The software can collect information about PLCs, temperature controllers, inverters and other equipment",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-22637"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002819"
      },
      {
        "db": "ZDI",
        "id": "ZDI-21-097"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17711"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22637"
      }
    ],
    "trust": 2.88
  },
  "external_ids": {
    "_id": null,
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2021-22637",
        "trust": 3.8
      },
      {
        "db": "ZDI",
        "id": "ZDI-21-097",
        "trust": 3.2
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-21-026-01",
        "trust": 3.1
      },
      {
        "db": "JVN",
        "id": "JVNVU93293369",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002819",
        "trust": 0.8
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-11170",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17711",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2021.0297",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2406",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22637",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-097"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17711"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22637"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002819"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2406"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22637"
      }
    ]
  },
  "id": "VAR-202101-1103",
  "iot": {
    "_id": null,
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17711"
      }
    ],
    "trust": 1.53529412
  },
  "iot_taxonomy": {
    "_id": null,
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17711"
      }
    ]
  },
  "last_update_date": "2024-11-23T19:25:31.113000Z",
  "patch": {
    "_id": null,
    "data": [
      {
        "title": "Top\u00a0Page",
        "trust": 0.8,
        "url": "https://www.fujielectric.com/index.html"
      },
      {
        "title": "Fuji Electric has issued an update to correct this vulnerability.",
        "trust": 0.7,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
      },
      {
        "title": "Patch for Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite buffer overflow vulnerabilities",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/252811"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-097"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17711"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002819"
      }
    ]
  },
  "problemtype_data": {
    "_id": null,
    "data": [
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002819"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22637"
      }
    ]
  },
  "references": {
    "_id": null,
    "data": [
      {
        "trust": 4.4,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
      },
      {
        "trust": 2.5,
        "url": "https://www.zerodayinitiative.com/advisories/zdi-21-097/"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-22637"
      },
      {
        "trust": 0.8,
        "url": "http://jvn.jp/vu/jvnvu93293369/index.html"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2021.0297/"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/787.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-097"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17711"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22637"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002819"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2406"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22637"
      }
    ]
  },
  "sources": {
    "_id": null,
    "data": [
      {
        "db": "ZDI",
        "id": "ZDI-21-097",
        "ident": null
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17711",
        "ident": null
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22637",
        "ident": null
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002819",
        "ident": null
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2406",
        "ident": null
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22637",
        "ident": null
      }
    ]
  },
  "sources_release_date": {
    "_id": null,
    "data": [
      {
        "date": "2021-01-29T00:00:00",
        "db": "ZDI",
        "id": "ZDI-21-097",
        "ident": null
      },
      {
        "date": "2021-03-16T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-17711",
        "ident": null
      },
      {
        "date": "2021-01-27T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-22637",
        "ident": null
      },
      {
        "date": "2021-10-05T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-002819",
        "ident": null
      },
      {
        "date": "2021-01-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-2406",
        "ident": null
      },
      {
        "date": "2021-01-27T20:15:12.770000",
        "db": "NVD",
        "id": "CVE-2021-22637",
        "ident": null
      }
    ]
  },
  "sources_update_date": {
    "_id": null,
    "data": [
      {
        "date": "2021-01-29T00:00:00",
        "db": "ZDI",
        "id": "ZDI-21-097",
        "ident": null
      },
      {
        "date": "2021-03-16T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-17711",
        "ident": null
      },
      {
        "date": "2021-01-29T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-22637",
        "ident": null
      },
      {
        "date": "2021-10-05T08:53:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-002819",
        "ident": null
      },
      {
        "date": "2021-02-01T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-2406",
        "ident": null
      },
      {
        "date": "2024-11-21T05:50:21.713000",
        "db": "NVD",
        "id": "CVE-2021-22637",
        "ident": null
      }
    ]
  },
  "threat_type": {
    "_id": null,
    "data": "local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2406"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "_id": null,
    "data": "V-Simulator\u00a0 and \u00a0V-Server\u00a0Lite\u00a0 Out-of-bounds Vulnerability in Microsoft",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002819"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "_id": null,
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2406"
      }
    ],
    "trust": 0.6
  }
}

var-201707-1005
Vulnerability from variot

An issue was discovered in Fuji Electric V-Server Version 3.3.22.0 and prior. A memory corruption vulnerability has been identified (aka improper restriction of operations within the bounds of a memory buffer), which may allow remote code execution. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within parsing of a VPR file. The issue results from the lack of proper validation of user-supplied data which can result in a memory corruption condition. An attacker can leverage this vulnerability to execute arbitrary code under the context of the current process. Fuji Electric V-Server is a data collection software from Fuji Electric of Japan. Failed attacks will cause denial of service conditions

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201707-1005",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "v-server",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "3.3.22.0"
      },
      {
        "model": "v-server",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "fuji electric",
        "version": "3.3.22.0"
      },
      {
        "model": "v-server",
        "scope": null,
        "trust": 0.7,
        "vendor": "fuji electric",
        "version": null
      },
      {
        "model": "electric v-server",
        "scope": "lte",
        "trust": 0.6,
        "vendor": "fuji",
        "version": "\u003c=3.3.22.0"
      },
      {
        "model": "v-server",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "fujielectric",
        "version": "3.3.22.0"
      },
      {
        "model": "electric v-server",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "3.3.22.0"
      },
      {
        "model": "electric v-server",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "0"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "v server",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "d5865a84-e9fb-47b5-8f83-edac0330897f"
      },
      {
        "db": "ZDI",
        "id": "ZDI-17-485"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-22993"
      },
      {
        "db": "BID",
        "id": "99544"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-005845"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201706-864"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-9639"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:fujielectric:v-server",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-005845"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Ariele Caltabiano (kimiya)",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-17-485"
      }
    ],
    "trust": 0.7
  },
  "cve": "CVE-2017-9639",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2017-9639",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "ZDI",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CVE-2017-9639",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "MEDIUM",
            "trust": 0.7,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2017-22993",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "d5865a84-e9fb-47b5-8f83-edac0330897f",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.9 [IVD]"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "LOW",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 3.9,
            "id": "CVE-2017-9639",
            "impactScore": 3.4,
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2017-9639",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2017-9639",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "ZDI",
            "id": "CVE-2017-9639",
            "trust": 0.7,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2017-22993",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201706-864",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "IVD",
            "id": "d5865a84-e9fb-47b5-8f83-edac0330897f",
            "trust": 0.2,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "d5865a84-e9fb-47b5-8f83-edac0330897f"
      },
      {
        "db": "ZDI",
        "id": "ZDI-17-485"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-22993"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-005845"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201706-864"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-9639"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered in Fuji Electric V-Server Version 3.3.22.0 and prior. A memory corruption vulnerability has been identified (aka improper restriction of operations within the bounds of a memory buffer), which may allow remote code execution.  User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within parsing of a VPR file. The issue results from the lack of proper validation of user-supplied data which can result in a memory corruption condition.  An attacker can leverage this vulnerability to execute arbitrary code under the context of the current process. Fuji Electric V-Server is a data collection software from Fuji Electric of Japan. Failed attacks will cause denial of service conditions",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-9639"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-005845"
      },
      {
        "db": "ZDI",
        "id": "ZDI-17-485"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-22993"
      },
      {
        "db": "BID",
        "id": "99544"
      },
      {
        "db": "IVD",
        "id": "d5865a84-e9fb-47b5-8f83-edac0330897f"
      }
    ],
    "trust": 3.24
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2017-9639",
        "trust": 4.2
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-17-192-02",
        "trust": 2.7
      },
      {
        "db": "BID",
        "id": "99544",
        "trust": 1.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-22993",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201706-864",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-005845",
        "trust": 0.8
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-4030",
        "trust": 0.7
      },
      {
        "db": "ZDI",
        "id": "ZDI-17-485",
        "trust": 0.7
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-17-192-03",
        "trust": 0.6
      },
      {
        "db": "IVD",
        "id": "D5865A84-E9FB-47B5-8F83-EDAC0330897F",
        "trust": 0.2
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "d5865a84-e9fb-47b5-8f83-edac0330897f"
      },
      {
        "db": "ZDI",
        "id": "ZDI-17-485"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-22993"
      },
      {
        "db": "BID",
        "id": "99544"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-005845"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201706-864"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-9639"
      }
    ]
  },
  "id": "VAR-201707-1005",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "d5865a84-e9fb-47b5-8f83-edac0330897f"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-22993"
      }
    ],
    "trust": 1.67058824
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "d5865a84-e9fb-47b5-8f83-edac0330897f"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-22993"
      }
    ]
  },
  "last_update_date": "2024-11-23T21:53:56.772000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "\u30c8\u30c3\u30d7\u30da\u30fc\u30b8",
        "trust": 0.8,
        "url": "http://www.fujielectric.co.jp/"
      },
      {
        "title": "Fuji Electric has issued an update to correct this vulnerability.",
        "trust": 0.7,
        "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-192-02"
      },
      {
        "title": "Fuji Electric V-Server Memory Corruption Vulnerability Patch",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/100865"
      },
      {
        "title": "Fuji Electric V-Server Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=99873"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-17-485"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-22993"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-005845"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201706-864"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-005845"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-9639"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.4,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-17-192-02"
      },
      {
        "trust": 1.6,
        "url": "http://www.securityfocus.com/bid/99544"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-9639"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-9639"
      },
      {
        "trust": 0.6,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-17-192-03"
      },
      {
        "trust": 0.3,
        "url": "http://www.fujielectric.com/"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-17-485"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-22993"
      },
      {
        "db": "BID",
        "id": "99544"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-005845"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201706-864"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-9639"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "d5865a84-e9fb-47b5-8f83-edac0330897f"
      },
      {
        "db": "ZDI",
        "id": "ZDI-17-485"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-22993"
      },
      {
        "db": "BID",
        "id": "99544"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-005845"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201706-864"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-9639"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-08-25T00:00:00",
        "db": "IVD",
        "id": "d5865a84-e9fb-47b5-8f83-edac0330897f"
      },
      {
        "date": "2017-07-12T00:00:00",
        "db": "ZDI",
        "id": "ZDI-17-485"
      },
      {
        "date": "2017-08-25T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-22993"
      },
      {
        "date": "2017-07-11T00:00:00",
        "db": "BID",
        "id": "99544"
      },
      {
        "date": "2017-08-08T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-005845"
      },
      {
        "date": "2017-06-21T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201706-864"
      },
      {
        "date": "2017-07-17T19:29:00.340000",
        "db": "NVD",
        "id": "CVE-2017-9639"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-07-12T00:00:00",
        "db": "ZDI",
        "id": "ZDI-17-485"
      },
      {
        "date": "2017-08-25T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-22993"
      },
      {
        "date": "2017-07-11T00:00:00",
        "db": "BID",
        "id": "99544"
      },
      {
        "date": "2017-08-08T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-005845"
      },
      {
        "date": "2019-10-17T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201706-864"
      },
      {
        "date": "2024-11-21T03:36:34.153000",
        "db": "NVD",
        "id": "CVE-2017-9639"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201706-864"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Fuji Electric V-Server Memory corruption vulnerability",
    "sources": [
      {
        "db": "IVD",
        "id": "d5865a84-e9fb-47b5-8f83-edac0330897f"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-22993"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-005845"
      }
    ],
    "trust": 1.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Buffer error",
    "sources": [
      {
        "db": "IVD",
        "id": "d5865a84-e9fb-47b5-8f83-edac0330897f"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201706-864"
      }
    ],
    "trust": 0.8
  }
}

var-201809-0157
Vulnerability from variot

Fuji Electric V-Server 4.0.3.0 and prior, A stack-based buffer overflow vulnerability has been identified, which may allow remote code execution. Fuji Electric V-Server Contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of a VPR file. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code under the context of the process. Fuji Electric V-Server VPR is a data collection software from Fuji Electric of Japan. Fuji Electric V-Server is prone to multiple security vulnerabilities: 1. A use-after-free vulnerability 2. Multiple untrusted pointer dereference remote code-execution vulnerabilities 3. Multiple out-of-bounds write vulnerabilities 5. An integer underflow vulnerability 6. An out-of-bounds read vulnerability 7. V-Server 4.0.3.0 and prior are vulnerable

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201809-0157",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "v-server",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "4.0.3.0"
      },
      {
        "model": "v-server",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "fuji electric",
        "version": "4.0.3.0"
      },
      {
        "model": "v-server",
        "scope": null,
        "trust": 0.7,
        "vendor": "fuji electric",
        "version": null
      },
      {
        "model": "electric v-server vpr",
        "scope": "lte",
        "trust": 0.6,
        "vendor": "fuji",
        "version": "\u003c=4.0.3.0"
      },
      {
        "model": "v-server",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "fujielectric",
        "version": "4.0.3.0"
      },
      {
        "model": "electric v-server",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "4.0.3.0"
      },
      {
        "model": "electric v-server",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "4.0.1.0"
      },
      {
        "model": "electric v-server",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "4.0.0.0"
      },
      {
        "model": "electric v-server",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "3.3.22.0"
      },
      {
        "model": "electric v-server",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "4.0.4.0"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "v server",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2fd1b23-39ab-11e9-8157-000c29342cb1"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1012"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-19612"
      },
      {
        "db": "BID",
        "id": "105341"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010431"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-582"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14823"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:fujielectric:v-server_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010431"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Ghirmay Desta",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-18-1012"
      }
    ],
    "trust": 0.7
  },
  "cve": "CVE-2018-14823",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-14823",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "ZDI",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CVE-2018-14823",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "MEDIUM",
            "trust": 0.7,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2018-19612",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "e2fd1b23-39ab-11e9-8157-000c29342cb1",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "VHN-125021",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-14823",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2018-14823",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-14823",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-14823",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "ZDI",
            "id": "CVE-2018-14823",
            "trust": 0.7,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2018-19612",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201809-582",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "IVD",
            "id": "e2fd1b23-39ab-11e9-8157-000c29342cb1",
            "trust": 0.2,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-125021",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2fd1b23-39ab-11e9-8157-000c29342cb1"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1012"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-19612"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125021"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010431"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-582"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14823"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Fuji Electric V-Server 4.0.3.0 and prior, A stack-based buffer overflow vulnerability has been identified, which may allow remote code execution. Fuji Electric V-Server Contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of a VPR file. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code under the context of the process. Fuji Electric V-Server VPR is a data collection software from Fuji Electric of Japan. Fuji Electric V-Server is prone to multiple security vulnerabilities:\n1. A use-after-free vulnerability\n2. Multiple untrusted pointer dereference remote code-execution vulnerabilities\n3. Multiple out-of-bounds write vulnerabilities\n5. An integer underflow vulnerability\n6. An out-of-bounds read vulnerability\n7. \nV-Server 4.0.3.0 and prior are vulnerable",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-14823"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010431"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1012"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-19612"
      },
      {
        "db": "BID",
        "id": "105341"
      },
      {
        "db": "IVD",
        "id": "e2fd1b23-39ab-11e9-8157-000c29342cb1"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125021"
      }
    ],
    "trust": 3.33
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-14823",
        "trust": 4.3
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-18-254-01",
        "trust": 2.8
      },
      {
        "db": "BID",
        "id": "105341",
        "trust": 2.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-582",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-19612",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010431",
        "trust": 0.8
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-5889",
        "trust": 0.7
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1012",
        "trust": 0.7
      },
      {
        "db": "IVD",
        "id": "E2FD1B23-39AB-11E9-8157-000C29342CB1",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-125021",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2fd1b23-39ab-11e9-8157-000c29342cb1"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1012"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-19612"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125021"
      },
      {
        "db": "BID",
        "id": "105341"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010431"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-582"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14823"
      }
    ]
  },
  "id": "VAR-201809-0157",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "e2fd1b23-39ab-11e9-8157-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-19612"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125021"
      }
    ],
    "trust": 1.77058824
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2fd1b23-39ab-11e9-8157-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-19612"
      }
    ]
  },
  "last_update_date": "2024-11-23T21:38:24.141000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "\u30c8\u30c3\u30d7\u30da\u30fc\u30b8",
        "trust": 0.8,
        "url": "http://www.fujielectric.co.jp/"
      },
      {
        "title": "Fuji Electric has issued an update to correct this vulnerability.",
        "trust": 0.7,
        "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
      },
      {
        "title": "Patch for Fuji Electric V-Server Buffer Overflow Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/140889"
      },
      {
        "title": "Fuji Electric V-Server VPR Buffer error vulnerability fix",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=84850"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-18-1012"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-19612"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010431"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-582"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-119",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-125021"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010431"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14823"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.5,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-254-01"
      },
      {
        "trust": 2.3,
        "url": "http://www.securityfocus.com/bid/105341"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14823"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-14823"
      },
      {
        "trust": 0.3,
        "url": "http://www.fujielectric.com/"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-18-1012"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-19612"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125021"
      },
      {
        "db": "BID",
        "id": "105341"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010431"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-582"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14823"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "e2fd1b23-39ab-11e9-8157-000c29342cb1"
      },
      {
        "db": "ZDI",
        "id": "ZDI-18-1012"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-19612"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125021"
      },
      {
        "db": "BID",
        "id": "105341"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010431"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-582"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14823"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-09-21T00:00:00",
        "db": "IVD",
        "id": "e2fd1b23-39ab-11e9-8157-000c29342cb1"
      },
      {
        "date": "2018-09-12T00:00:00",
        "db": "ZDI",
        "id": "ZDI-18-1012"
      },
      {
        "date": "2018-09-21T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-19612"
      },
      {
        "date": "2018-09-26T00:00:00",
        "db": "VULHUB",
        "id": "VHN-125021"
      },
      {
        "date": "2018-09-11T00:00:00",
        "db": "BID",
        "id": "105341"
      },
      {
        "date": "2018-12-14T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-010431"
      },
      {
        "date": "2018-09-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201809-582"
      },
      {
        "date": "2018-09-26T20:29:00.980000",
        "db": "NVD",
        "id": "CVE-2018-14823"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-09-12T00:00:00",
        "db": "ZDI",
        "id": "ZDI-18-1012"
      },
      {
        "date": "2018-10-12T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-19612"
      },
      {
        "date": "2020-08-28T00:00:00",
        "db": "VULHUB",
        "id": "VHN-125021"
      },
      {
        "date": "2018-09-11T00:00:00",
        "db": "BID",
        "id": "105341"
      },
      {
        "date": "2018-12-14T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-010431"
      },
      {
        "date": "2019-10-17T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201809-582"
      },
      {
        "date": "2024-11-21T03:49:52.330000",
        "db": "NVD",
        "id": "CVE-2018-14823"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-582"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Fuji Electric V-Server Buffer error vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010431"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Buffer error",
    "sources": [
      {
        "db": "IVD",
        "id": "e2fd1b23-39ab-11e9-8157-000c29342cb1"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-582"
      }
    ],
    "trust": 0.8
  }
}

var-201809-0154
Vulnerability from variot

Fuji Electric V-Server 4.0.3.0 and prior, An integer underflow vulnerability has been identified, which may allow remote code execution. Fuji Electric V-Server VPR is a data collection software from Fuji Electric of Japan. A remote attacker could exploit the vulnerability to execute code. Fuji Electric V-Server is prone to multiple security vulnerabilities: 1. A use-after-free vulnerability 2. Multiple untrusted pointer dereference remote code-execution vulnerabilities 3. A heap-based buffer overflow vulnerability 4. Multiple out-of-bounds write vulnerabilities 5. An integer underflow vulnerability 6. An out-of-bounds read vulnerability 7. V-Server 4.0.3.0 and prior are vulnerable

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201809-0154",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "v-server",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "4.0.3.0"
      },
      {
        "model": "v-server",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "fuji electric",
        "version": "4.0.3.0"
      },
      {
        "model": "electric v-server vpr",
        "scope": "lte",
        "trust": 0.6,
        "vendor": "fuji",
        "version": "\u003c=4.0.3.0"
      },
      {
        "model": "v-server",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "fujielectric",
        "version": "4.0.3.0"
      },
      {
        "model": "electric v-server",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "4.0.3.0"
      },
      {
        "model": "electric v-server",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "4.0.1.0"
      },
      {
        "model": "electric v-server",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "4.0.0.0"
      },
      {
        "model": "electric v-server",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "3.3.22.0"
      },
      {
        "model": "electric v-server",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "fuji",
        "version": "4.0.4.0"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "v server",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2fd6940-39ab-11e9-8108-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20784"
      },
      {
        "db": "BID",
        "id": "105341"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010417"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-580"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14817"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:fujielectric:v-server",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010417"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Steven Seeley (mr_me) of Source Incite and Ghirmay Desta working with Trend Micro??s Zero Day Initiative",
    "sources": [
      {
        "db": "BID",
        "id": "105341"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2018-14817",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-14817",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2018-20784",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "e2fd6940-39ab-11e9-8108-000c29342cb1",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "VHN-125014",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-14817",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-14817",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-14817",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2018-20784",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201809-580",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "IVD",
            "id": "e2fd6940-39ab-11e9-8108-000c29342cb1",
            "trust": 0.2,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-125014",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2fd6940-39ab-11e9-8108-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20784"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125014"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010417"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-580"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14817"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Fuji Electric V-Server 4.0.3.0 and prior, An integer underflow vulnerability has been identified, which may allow remote code execution. Fuji Electric V-Server VPR is a data collection software from Fuji Electric of Japan. A remote attacker could exploit the vulnerability to execute code. Fuji Electric V-Server is prone to multiple security vulnerabilities:\n1. A use-after-free vulnerability\n2. Multiple untrusted pointer dereference remote code-execution vulnerabilities\n3. A heap-based buffer overflow vulnerability\n4. Multiple out-of-bounds write vulnerabilities\n5. An integer underflow vulnerability\n6. An out-of-bounds read vulnerability\n7. \nV-Server 4.0.3.0 and prior are vulnerable",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-14817"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010417"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20784"
      },
      {
        "db": "BID",
        "id": "105341"
      },
      {
        "db": "IVD",
        "id": "e2fd6940-39ab-11e9-8108-000c29342cb1"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125014"
      }
    ],
    "trust": 2.7
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-14817",
        "trust": 3.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-18-254-01",
        "trust": 2.8
      },
      {
        "db": "BID",
        "id": "105341",
        "trust": 2.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-580",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20784",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010417",
        "trust": 0.8
      },
      {
        "db": "IVD",
        "id": "E2FD6940-39AB-11E9-8108-000C29342CB1",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-125014",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2fd6940-39ab-11e9-8108-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20784"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125014"
      },
      {
        "db": "BID",
        "id": "105341"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010417"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-580"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14817"
      }
    ]
  },
  "id": "VAR-201809-0154",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "e2fd6940-39ab-11e9-8108-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20784"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125014"
      }
    ],
    "trust": 1.77058824
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2fd6940-39ab-11e9-8108-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20784"
      }
    ]
  },
  "last_update_date": "2024-11-23T21:38:23.896000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "\u30c8\u30c3\u30d7\u30da\u30fc\u30b8",
        "trust": 0.8,
        "url": "https://www.fujielectric.co.jp/"
      },
      {
        "title": "Patch for Fuji Electric V-Server Integer Overflow Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/142217"
      },
      {
        "title": "Fuji Electric V-Server VPR Fixes for digital error vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=84847"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-20784"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010417"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-580"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-191",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-125014"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010417"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14817"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.8,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-254-01"
      },
      {
        "trust": 2.3,
        "url": "http://www.securityfocus.com/bid/105341"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14817"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-14817"
      },
      {
        "trust": 0.3,
        "url": "http://www.fujielectric.com/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-20784"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125014"
      },
      {
        "db": "BID",
        "id": "105341"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010417"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-580"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14817"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "e2fd6940-39ab-11e9-8108-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20784"
      },
      {
        "db": "VULHUB",
        "id": "VHN-125014"
      },
      {
        "db": "BID",
        "id": "105341"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010417"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-580"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14817"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-10-12T00:00:00",
        "db": "IVD",
        "id": "e2fd6940-39ab-11e9-8108-000c29342cb1"
      },
      {
        "date": "2018-10-12T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-20784"
      },
      {
        "date": "2018-09-26T00:00:00",
        "db": "VULHUB",
        "id": "VHN-125014"
      },
      {
        "date": "2018-09-11T00:00:00",
        "db": "BID",
        "id": "105341"
      },
      {
        "date": "2018-12-13T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-010417"
      },
      {
        "date": "2018-09-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201809-580"
      },
      {
        "date": "2018-09-26T20:29:00.747000",
        "db": "NVD",
        "id": "CVE-2018-14817"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-10-12T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-20784"
      },
      {
        "date": "2019-10-09T00:00:00",
        "db": "VULHUB",
        "id": "VHN-125014"
      },
      {
        "date": "2018-09-11T00:00:00",
        "db": "BID",
        "id": "105341"
      },
      {
        "date": "2018-12-13T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-010417"
      },
      {
        "date": "2019-10-17T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201809-580"
      },
      {
        "date": "2024-11-21T03:49:51.510000",
        "db": "NVD",
        "id": "CVE-2018-14817"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-580"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Fuji Electric V-Server Integer Overflow Vulnerability",
    "sources": [
      {
        "db": "IVD",
        "id": "e2fd6940-39ab-11e9-8108-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-20784"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "digital error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-580"
      }
    ],
    "trust": 0.6
  }
}

var-202101-0897
Vulnerability from variot

Multiple out-of-bounds write issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0). V-Simulator and V-Server Lite Is vulnerable to an out-of-bounds write.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite are both products of Fuji Electric, Japan. Fuji Electric Tellus Lite V-Simulator is a remote monitoring software for industrial environments. Fuji Electric V-Server Lite is a remote monitoring software for industrial environments. The software can collect information about PLCs, temperature controllers, inverters and other equipment.

Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite have an out-of-bounds write vulnerability, which can be exploited by attackers to execute arbitrary code

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202101-0897",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "v-server",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "4.0.10.0"
      },
      {
        "model": "v-simulator",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "4.0.10.0"
      },
      {
        "model": "v-simulator",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u5bcc\u58eb\u96fb\u6a5f",
        "version": "lite 4.0.10.0"
      },
      {
        "model": "v-server",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u5bcc\u58eb\u96fb\u6a5f",
        "version": null
      },
      {
        "model": "electric tellus lite v-simulator",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "fuji",
        "version": "4.0.10.0"
      },
      {
        "model": "electric v-server lite",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "fuji",
        "version": "4.0.10.0"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17709"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002822"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22653"
      }
    ]
  },
  "cve": "CVE-2021-22653",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CVE-2021-22653",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.9,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CNVD-2021-17709",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2021-22653",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Local",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2021-22653",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "Required",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2021-22653",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2021-22653",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2021-17709",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202101-2401",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2021-22653",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17709"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22653"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002822"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2401"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22653"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Multiple out-of-bounds write issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0). V-Simulator and V-Server Lite Is vulnerable to an out-of-bounds write.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite are both products of Fuji Electric, Japan. Fuji Electric Tellus Lite V-Simulator is a remote monitoring software for industrial environments. Fuji Electric V-Server Lite is a remote monitoring software for industrial environments. The software can collect information about PLCs, temperature controllers, inverters and other equipment. \n\r\n\r\nFuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite have an out-of-bounds write vulnerability, which can be exploited by attackers to execute arbitrary code",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-22653"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002822"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17709"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22653"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "ICS CERT",
        "id": "ICSA-21-026-01",
        "trust": 3.1
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22653",
        "trust": 3.1
      },
      {
        "db": "JVN",
        "id": "JVNVU93293369",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002822",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17709",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2021.0297",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2401",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22653",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17709"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22653"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002822"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2401"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22653"
      }
    ]
  },
  "id": "VAR-202101-0897",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17709"
      }
    ],
    "trust": 1.53529412
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17709"
      }
    ]
  },
  "last_update_date": "2024-11-23T19:59:32.536000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top\u00a0Page",
        "trust": 0.8,
        "url": "https://www.fujielectric.com/index.html"
      },
      {
        "title": "Patch for Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite out-of-bounds write vulnerabilities",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/252821"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17709"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002822"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002822"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22653"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-22653"
      },
      {
        "trust": 0.8,
        "url": "http://jvn.jp/vu/jvnvu93293369/index.html"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2021.0297/"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/787.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17709"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22653"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002822"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2401"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22653"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17709"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22653"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002822"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2401"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22653"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-03-16T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-17709"
      },
      {
        "date": "2021-01-27T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-22653"
      },
      {
        "date": "2021-10-05T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-002822"
      },
      {
        "date": "2021-01-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-2401"
      },
      {
        "date": "2021-01-27T20:15:13.317000",
        "db": "NVD",
        "id": "CVE-2021-22653"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-03-16T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-17709"
      },
      {
        "date": "2021-01-29T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-22653"
      },
      {
        "date": "2021-10-05T08:53:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-002822"
      },
      {
        "date": "2021-02-01T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-2401"
      },
      {
        "date": "2024-11-21T05:50:24.550000",
        "db": "NVD",
        "id": "CVE-2021-22653"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2401"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "V-Simulator\u00a0 and \u00a0V-Server\u00a0Lite\u00a0 Out-of-bounds Vulnerability in Microsoft",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002822"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2401"
      }
    ],
    "trust": 0.6
  }
}

cve-2018-14819
Vulnerability from cvelistv5
Published
2018-09-26 20:00
Modified
2024-09-16 16:47
Severity ?
Summary
Fuji Electric V-Server 4.0.3.0 and prior, An out-of-bounds read vulnerability has been identified, which may allow remote code execution.
References
Impacted products
Vendor Product Version
Fuji Electric V-Server Version: 4.0.3.0 and prior
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T09:38:13.959Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
          },
          {
            "name": "105341",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/105341"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server",
          "vendor": "Fuji Electric",
          "versions": [
            {
              "status": "affected",
              "version": "4.0.3.0 and prior"
            }
          ]
        }
      ],
      "datePublic": "2018-09-11T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric V-Server 4.0.3.0 and prior, An out-of-bounds read vulnerability has been identified, which may allow remote code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "OUT-OF-BOUNDS READ CWE-125",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-09-27T09:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
        },
        {
          "name": "105341",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/105341"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-09-11T00:00:00",
          "ID": "CVE-2018-14819",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "V-Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "4.0.3.0 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Fuji Electric"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Fuji Electric V-Server 4.0.3.0 and prior, An out-of-bounds read vulnerability has been identified, which may allow remote code execution."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "OUT-OF-BOUNDS READ CWE-125"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
            },
            {
              "name": "105341",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/105341"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-14819",
    "datePublished": "2018-09-26T20:00:00Z",
    "dateReserved": "2018-08-01T00:00:00",
    "dateUpdated": "2024-09-16T16:47:54.538Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-18240
Vulnerability from cvelistv5
Published
2019-11-13 22:21
Modified
2024-08-05 01:47
Severity ?
Summary
In Fuji Electric V-Server 4.0.6 and prior, several heap-based buffer overflows have been identified, which may allow an attacker to remotely execute arbitrary code.
References
Impacted products
Vendor Product Version
n/a Fuji Electric V-Server 4.0.6 and prior Version: Fuji Electric V-Server 4.0.6 and prior
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T01:47:13.942Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-19-311-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Fuji Electric V-Server 4.0.6 and prior",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Fuji Electric V-Server 4.0.6 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In Fuji Electric V-Server 4.0.6 and prior, several heap-based buffer overflows have been identified, which may allow an attacker to remotely execute arbitrary code."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "HEAP-BASED BUFFER OVERFLOW CWE-122",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-11-13T22:21:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-19-311-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2019-18240",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Fuji Electric V-Server 4.0.6 and prior",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Fuji Electric V-Server 4.0.6 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In Fuji Electric V-Server 4.0.6 and prior, several heap-based buffer overflows have been identified, which may allow an attacker to remotely execute arbitrary code."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "HEAP-BASED BUFFER OVERFLOW CWE-122"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-19-311-02",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-19-311-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2019-18240",
    "datePublished": "2019-11-13T22:21:01",
    "dateReserved": "2019-10-22T00:00:00",
    "dateUpdated": "2024-08-05T01:47:13.942Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2018-14815
Vulnerability from cvelistv5
Published
2018-09-26 20:00
Modified
2024-08-05 09:38
Severity ?
Summary
Fuji Electric V-Server 4.0.3.0 and prior, Several out-of-bounds write vulnerabilities have been identified, which may allow remote code execution.
References
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T09:38:13.986Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
          },
          {
            "name": "105341",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/105341"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-09-11T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric V-Server 4.0.3.0 and prior, Several out-of-bounds write vulnerabilities have been identified, which may allow remote code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-09-27T09:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
        },
        {
          "name": "105341",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/105341"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2018-14815",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Fuji Electric V-Server 4.0.3.0 and prior, Several out-of-bounds write vulnerabilities have been identified, which may allow remote code execution."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
            },
            {
              "name": "105341",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/105341"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-14815",
    "datePublished": "2018-09-26T20:00:00",
    "dateReserved": "2018-08-01T00:00:00",
    "dateUpdated": "2024-08-05T09:38:13.986Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-38419
Vulnerability from cvelistv5
Published
2021-12-20 20:08
Modified
2024-08-04 01:44
Summary
Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds write, which can result in data corruption, a system crash, or code execution.
References
Impacted products
Vendor Product Version
Fuji Electric V-Server Lite Version: unspecified   < 4.0.12.0
Create a notification for this product.
   Fuji Electric Tellus Lite V-Simulator Version: unspecified   < 4.0.12.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:44:22.450Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server Lite",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Tellus Lite V-Simulator",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds write, which can result in data corruption, a system crash, or code execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787 Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-20T20:08:50",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
        }
      ],
      "source": {
        "advisory": "ICSA-21-299-01",
        "discovery": "EXTERNAL"
      },
      "title": " Fuji Electric Tellus Lite V-Simulator out of bounds write",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-38419",
          "STATE": "PUBLIC",
          "TITLE": " Fuji Electric Tellus Lite V-Simulator out of bounds write"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "V-Server Lite",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Tellus Lite V-Simulator",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": " Fuji Electric"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds write, which can result in data corruption, a system crash, or code execution."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-787 Out-of-bounds Write"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
          }
        ],
        "source": {
          "advisory": "ICSA-21-299-01",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-38419",
    "datePublished": "2021-12-20T20:08:50",
    "dateReserved": "2021-08-10T00:00:00",
    "dateUpdated": "2024-08-04T01:44:22.450Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-38415
Vulnerability from cvelistv5
Published
2021-12-20 20:08
Modified
2024-08-04 01:44
Summary
Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable a heap-based buffer overflow when parsing a specially crafted project file, which may allow an attacker to execute arbitrary code.
References
Impacted products
Vendor Product Version
Fuji Electric V-Server Lite Version: unspecified   < 4.0.12.0
Create a notification for this product.
   Fuji Electric Tellus Lite V-Simulator Version: unspecified   < 4.0.12.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:44:22.244Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server Lite",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Tellus Lite V-Simulator",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable a heap-based buffer overflow when parsing a specially crafted project file, which may allow an attacker to execute arbitrary code."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "CWE-122 Heap-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-20T20:08:48",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
        }
      ],
      "source": {
        "advisory": "ICSA-21-299-01",
        "discovery": "EXTERNAL"
      },
      "title": " Fuji Electric Tellus Lite V-Simulator heap based buffer overflow",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-38415",
          "STATE": "PUBLIC",
          "TITLE": " Fuji Electric Tellus Lite V-Simulator heap based buffer overflow"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "V-Server Lite",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Tellus Lite V-Simulator",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": " Fuji Electric"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable a heap-based buffer overflow when parsing a specially crafted project file, which may allow an attacker to execute arbitrary code."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-122 Heap-based Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
          }
        ],
        "source": {
          "advisory": "ICSA-21-299-01",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-38415",
    "datePublished": "2021-12-20T20:08:48",
    "dateReserved": "2021-08-10T00:00:00",
    "dateUpdated": "2024-08-04T01:44:22.244Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-47317
Vulnerability from cvelistv5
Published
2023-01-03 00:00
Modified
2024-08-03 14:47
Severity ?
Summary
Out-of-bounds write vulnerability in V-Server v4.0.12.0 and earlier allows a local attacker to obtain the information and/or execute arbitrary code by having a user to open a specially crafted project file.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T14:47:29.527Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/vu/JVNVU92811888/index.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server",
          "vendor": "FUJI ELECTRIC CO., LTD. and Hakko Electronics Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "v4.0.12.0 and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Out-of-bounds write vulnerability in V-Server v4.0.12.0 and earlier allows a local attacker to obtain the information and/or execute arbitrary code by having a user to open a specially crafted project file."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Out-of-bounds Write",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-01-03T00:00:00",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "url": "https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php"
        },
        {
          "url": "https://jvn.jp/en/vu/JVNVU92811888/index.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2022-47317",
    "datePublished": "2023-01-03T00:00:00",
    "dateReserved": "2022-12-26T00:00:00",
    "dateUpdated": "2024-08-03T14:47:29.527Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2018-14811
Vulnerability from cvelistv5
Published
2018-09-26 20:00
Modified
2024-09-16 20:41
Severity ?
Summary
Fuji Electric V-Server 4.0.3.0 and prior, Multiple untrusted pointer dereference vulnerabilities have been identified, which may allow remote code execution.
References
Impacted products
Vendor Product Version
Fuji Electric V-Server Version: 4.0.3.0 and prior
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T09:38:13.982Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
          },
          {
            "name": "105341",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/105341"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server",
          "vendor": "Fuji Electric",
          "versions": [
            {
              "status": "affected",
              "version": "4.0.3.0 and prior"
            }
          ]
        }
      ],
      "datePublic": "2018-09-11T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric V-Server 4.0.3.0 and prior, Multiple untrusted pointer dereference vulnerabilities have been identified, which may allow remote code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-822",
              "description": "UNTRUSTED POINTER DEREFERENCE CWE-822",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-09-27T09:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
        },
        {
          "name": "105341",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/105341"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-09-11T00:00:00",
          "ID": "CVE-2018-14811",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "V-Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "4.0.3.0 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Fuji Electric"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Fuji Electric V-Server 4.0.3.0 and prior, Multiple untrusted pointer dereference vulnerabilities have been identified, which may allow remote code execution."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "UNTRUSTED POINTER DEREFERENCE CWE-822"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
            },
            {
              "name": "105341",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/105341"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-14811",
    "datePublished": "2018-09-26T20:00:00Z",
    "dateReserved": "2018-08-01T00:00:00",
    "dateUpdated": "2024-09-16T20:41:49.709Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-31239
Vulnerability from cvelistv5
Published
2023-06-19 00:00
Modified
2024-12-23 21:34
Summary
Stack-based buffer overflow vulnerability in V-Server v4.0.15.0 and V-Server Lite v4.0.15.0 and earlier allows an attacker to execute arbitrary code by having user open a specially crafted VPR file.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:53:30.695Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/vu/JVNVU98818508/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2023-31239",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-12-23T21:34:08.650253Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-125",
                "description": "CWE-125 Out-of-bounds Read",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-12-23T21:34:13.092Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server and V-Server Lite",
          "vendor": "FUJI ELECTRIC CO., LTD. and Hakko Electronics Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "v4.0.15.0 and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Stack-based buffer overflow vulnerability in V-Server v4.0.15.0 and V-Server Lite v4.0.15.0 and earlier allows an attacker to execute arbitrary code by having user open a specially crafted VPR file."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-06-19T00:00:00",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "url": "https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php"
        },
        {
          "url": "https://jvn.jp/en/vu/JVNVU98818508/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2023-31239",
    "datePublished": "2023-06-19T00:00:00",
    "dateReserved": "2023-05-11T00:00:00",
    "dateUpdated": "2024-12-23T21:34:13.092Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-38413
Vulnerability from cvelistv5
Published
2021-12-20 20:08
Modified
2024-08-04 01:44
Summary
Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to a stack-based buffer overflow, which may allow an attacker to achieve code execution.
References
Impacted products
Vendor Product Version
Fuji Electric V-Server Lite Version: unspecified   < 4.0.12.0
Create a notification for this product.
   Fuji Electric Tellus Lite V-Simulator Version: unspecified   < 4.0.12.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:44:22.252Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server Lite",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Tellus Lite V-Simulator",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to a stack-based buffer overflow, which may allow an attacker to achieve code execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-20T20:08:49",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
        }
      ],
      "source": {
        "advisory": "ICSA-21-299-01",
        "discovery": "EXTERNAL"
      },
      "title": " Fuji Electric Tellus Lite V-Simulator stack based buffer overflow",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-38413",
          "STATE": "PUBLIC",
          "TITLE": " Fuji Electric Tellus Lite V-Simulator stack based buffer overflow"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "V-Server Lite",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Tellus Lite V-Simulator",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": " Fuji Electric"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to a stack-based buffer overflow, which may allow an attacker to achieve code execution."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121 Stack-based Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
          }
        ],
        "source": {
          "advisory": "ICSA-21-299-01",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-38413",
    "datePublished": "2021-12-20T20:08:49",
    "dateReserved": "2021-08-10T00:00:00",
    "dateUpdated": "2024-08-04T01:44:22.252Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-29524
Vulnerability from cvelistv5
Published
2022-06-14 07:05
Modified
2024-08-03 06:26
Severity ?
Summary
Out-of-bounds write vulnerability exists in V-Server v4.0.11.0 and earlier and V-Server Lite v4.0.13.0 and earlier, which may allow an attacker to obtain information and/or execute arbitrary code by having a user to open a specially crafted image file.
Impacted products
Vendor Product Version
FUJI ELECTRIC CO., LTD. / Hakko Electronics Co., Ltd. V-Server and V-Server Lite Version: V-Server v4.0.11.0 and earlier, and V-Server Lite v4.0.13.0 and earlier
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:26:06.068Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://monitouch.fujielectric.com/site/download-e/09vsft6_inf/Search.php"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://monitouch.fujielectric.com/site/download-eu/03tellus_inf/index.php"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/vu/JVNVU93134398/index.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server and V-Server Lite",
          "vendor": "FUJI ELECTRIC CO., LTD. / Hakko Electronics Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "V-Server v4.0.11.0 and earlier, and V-Server Lite v4.0.13.0 and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Out-of-bounds write vulnerability exists in V-Server v4.0.11.0 and earlier and V-Server Lite v4.0.13.0 and earlier, which may allow an attacker to obtain information and/or execute arbitrary code by having a user to open a specially crafted image file."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Out-of-bounds Write",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-14T07:05:45",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://monitouch.fujielectric.com/site/download-e/09vsft6_inf/Search.php"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://monitouch.fujielectric.com/site/download-eu/03tellus_inf/index.php"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jvn.jp/en/vu/JVNVU93134398/index.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vultures@jpcert.or.jp",
          "ID": "CVE-2022-29524",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "V-Server and V-Server Lite",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "V-Server v4.0.11.0 and earlier, and V-Server Lite v4.0.13.0 and earlier"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "FUJI ELECTRIC CO., LTD. / Hakko Electronics Co., Ltd."
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Out-of-bounds write vulnerability exists in V-Server v4.0.11.0 and earlier and V-Server Lite v4.0.13.0 and earlier, which may allow an attacker to obtain information and/or execute arbitrary code by having a user to open a specially crafted image file."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Out-of-bounds Write"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://monitouch.fujielectric.com/site/download-e/09vsft6_inf/Search.php",
              "refsource": "MISC",
              "url": "https://monitouch.fujielectric.com/site/download-e/09vsft6_inf/Search.php"
            },
            {
              "name": "https://monitouch.fujielectric.com/site/download-eu/03tellus_inf/index.php",
              "refsource": "MISC",
              "url": "https://monitouch.fujielectric.com/site/download-eu/03tellus_inf/index.php"
            },
            {
              "name": "https://jvn.jp/en/vu/JVNVU93134398/index.html",
              "refsource": "MISC",
              "url": "https://jvn.jp/en/vu/JVNVU93134398/index.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2022-29524",
    "datePublished": "2022-06-14T07:05:45",
    "dateReserved": "2022-05-23T00:00:00",
    "dateUpdated": "2024-08-03T06:26:06.068Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2018-14809
Vulnerability from cvelistv5
Published
2018-09-26 20:00
Modified
2024-09-16 22:03
Severity ?
Summary
Fuji Electric V-Server 4.0.3.0 and prior, A use after free vulnerability has been identified, which may allow remote code execution.
References
Impacted products
Vendor Product Version
Fuji Electric V-Server Version: 4.0.3.0 and prior
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T09:38:14.042Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server",
          "vendor": "Fuji Electric",
          "versions": [
            {
              "status": "affected",
              "version": "4.0.3.0 and prior"
            }
          ]
        }
      ],
      "datePublic": "2018-09-11T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric V-Server 4.0.3.0 and prior, A use after free vulnerability has been identified, which may allow remote code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-416",
              "description": "USE AFTER FREE CWE-416",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-09-26T19:57:02",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-09-11T00:00:00",
          "ID": "CVE-2018-14809",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "V-Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "4.0.3.0 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Fuji Electric"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Fuji Electric V-Server 4.0.3.0 and prior, A use after free vulnerability has been identified, which may allow remote code execution."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "USE AFTER FREE CWE-416"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-14809",
    "datePublished": "2018-09-26T20:00:00Z",
    "dateReserved": "2018-08-01T00:00:00",
    "dateUpdated": "2024-09-16T22:03:37.405Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-22637
Vulnerability from cvelistv5
Published
2021-01-27 19:09
Modified
2024-08-03 18:44
Severity ?
Summary
Multiple stack-based buffer overflow issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0).
Impacted products
Vendor Product Version
n/a Tellus Lite V-Simulator and V-Server Lite Version: Versions prior to 4.0.10.0
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:44:14.149Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-097/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Tellus Lite V-Simulator and V-Server Lite",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Versions prior to 4.0.10.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Multiple stack-based buffer overflow issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0)."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "STACK-BASED BUFFER OVERFLOW CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-01-29T07:06:36",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-097/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-22637",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Tellus Lite V-Simulator and V-Server Lite",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Versions prior to 4.0.10.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Multiple stack-based buffer overflow issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0)."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "STACK-BASED BUFFER OVERFLOW CWE-121"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
            },
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-097/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-097/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-22637",
    "datePublished": "2021-01-27T19:09:49",
    "dateReserved": "2021-01-05T00:00:00",
    "dateUpdated": "2024-08-03T18:44:14.149Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-22653
Vulnerability from cvelistv5
Published
2021-01-27 19:01
Modified
2024-08-03 18:51
Severity ?
Summary
Multiple out-of-bounds write issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0).
References
Impacted products
Vendor Product Version
n/a Tellus Lite V-Simulator and V-Server Lite Version: Versions prior to 4.0.10.0
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:51:05.842Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Tellus Lite V-Simulator and V-Server Lite",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Versions prior to 4.0.10.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Multiple out-of-bounds write issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0)."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "OUT-OF-BOUNDS WRITE CWE-787",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-01-27T19:01:55",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-22653",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Tellus Lite V-Simulator and V-Server Lite",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Versions prior to 4.0.10.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Multiple out-of-bounds write issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0)."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "OUT-OF-BOUNDS WRITE CWE-787"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-22653",
    "datePublished": "2021-01-27T19:01:55",
    "dateReserved": "2021-01-05T00:00:00",
    "dateUpdated": "2024-08-03T18:51:05.842Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2020-25171
Vulnerability from cvelistv5
Published
2021-02-19 17:06
Modified
2024-08-04 15:26
Severity ?
Summary
The affected Fuji Electric V-Server Lite versions prior to 3.3.24.0 are vulnerable to an out-of-bounds write, which may allow an attacker to remotely execute arbitrary code.
References
Impacted products
Vendor Product Version
Fuji Electric V-Server Lite Version: unspecified   < 3.3.24.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T15:26:10.248Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-329-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server Lite",
          "vendor": "Fuji Electric",
          "versions": [
            {
              "lessThan": "3.3.24.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The affected Fuji Electric V-Server Lite versions prior to 3.3.24.0 are vulnerable to an out-of-bounds write, which may allow an attacker to remotely execute arbitrary code."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "OUT-OF-BOUNDS WRITE CWE-787",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-02-19T17:06:18",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-329-02"
        }
      ],
      "source": {
        "advisory": "ICSA-20-329-02",
        "discovery": "UNKNOWN"
      },
      "title": "Fuji Electric V-Server Lite",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-25171",
          "STATE": "PUBLIC",
          "TITLE": "Fuji Electric V-Server Lite"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "V-Server Lite",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "3.3.24.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Fuji Electric"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The affected Fuji Electric V-Server Lite versions prior to 3.3.24.0 are vulnerable to an out-of-bounds write, which may allow an attacker to remotely execute arbitrary code."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "OUT-OF-BOUNDS WRITE CWE-787"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-329-02",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-329-02"
            }
          ]
        },
        "source": {
          "advisory": "ICSA-20-329-02",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-25171",
    "datePublished": "2021-02-19T17:06:18",
    "dateReserved": "2020-09-04T00:00:00",
    "dateUpdated": "2024-08-04T15:26:10.248Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-29506
Vulnerability from cvelistv5
Published
2022-06-14 07:05
Modified
2024-08-03 06:26
Severity ?
Summary
Out-of-bounds read vulnerability exist in the simulator module contained in the graphic editor 'V-SFT' v6.1.3.0 and earlier, which may allow an attacker to obtain information and/or execute arbitrary code by having a user to open a specially crafted image file.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:26:06.231Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://monitouch.fujielectric.com/site/download-e/09vsft6_inf/Search.php"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://monitouch.fujielectric.com/site/download-eu/03tellus_inf/index.php"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/vu/JVNVU93134398/index.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-SFT",
          "vendor": "FUJI ELECTRIC CO., LTD. / Hakko Electronics Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "v6.1.3.0 and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Out-of-bounds read vulnerability exist in the simulator module contained in the graphic editor \u0027V-SFT\u0027 v6.1.3.0 and earlier, which may allow an attacker to obtain information and/or execute arbitrary code by having a user to open a specially crafted image file."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Out-of-bounds Read",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-14T07:05:41",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://monitouch.fujielectric.com/site/download-e/09vsft6_inf/Search.php"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://monitouch.fujielectric.com/site/download-eu/03tellus_inf/index.php"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jvn.jp/en/vu/JVNVU93134398/index.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vultures@jpcert.or.jp",
          "ID": "CVE-2022-29506",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "V-SFT",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "v6.1.3.0 and earlier"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "FUJI ELECTRIC CO., LTD. / Hakko Electronics Co., Ltd."
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Out-of-bounds read vulnerability exist in the simulator module contained in the graphic editor \u0027V-SFT\u0027 v6.1.3.0 and earlier, which may allow an attacker to obtain information and/or execute arbitrary code by having a user to open a specially crafted image file."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://monitouch.fujielectric.com/site/download-e/09vsft6_inf/Search.php",
              "refsource": "MISC",
              "url": "https://monitouch.fujielectric.com/site/download-e/09vsft6_inf/Search.php"
            },
            {
              "name": "https://monitouch.fujielectric.com/site/download-eu/03tellus_inf/index.php",
              "refsource": "MISC",
              "url": "https://monitouch.fujielectric.com/site/download-eu/03tellus_inf/index.php"
            },
            {
              "name": "https://jvn.jp/en/vu/JVNVU93134398/index.html",
              "refsource": "MISC",
              "url": "https://jvn.jp/en/vu/JVNVU93134398/index.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2022-29506",
    "datePublished": "2022-06-14T07:05:41",
    "dateReserved": "2022-05-23T00:00:00",
    "dateUpdated": "2024-08-03T06:26:06.231Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-47586
Vulnerability from cvelistv5
Published
2023-11-15 06:03
Modified
2024-08-29 17:50
Severity ?
Summary
Multiple heap-based buffer overflow vulnerabilities exist in V-Server V4.0.18.0 and earlier and V-Server Lite V4.0.18.0 and earlier. If a user opens a specially crafted VPR file, information may be disclosed and/or arbitrary code may be executed.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T21:09:37.352Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://hakko-elec.co.jp/site/download/03tellus_inf/index.php"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/vu/JVNVU93840158/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:fujielectric:v-server_lite:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "v-server_lite",
            "vendor": "fujielectric",
            "versions": [
              {
                "lessThan": "V4.0.18.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-47586",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-29T17:48:25.083109Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-29T17:50:00.621Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server",
          "vendor": "FUJI ELECTRIC CO., LTD. and Hakko Electronics Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "V4.0.18.0 and earlier"
            }
          ]
        },
        {
          "product": "V-Server Lite",
          "vendor": "FUJI ELECTRIC CO., LTD. and Hakko Electronics Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "V4.0.18.0 and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Multiple heap-based buffer overflow vulnerabilities exist in V-Server V4.0.18.0 and earlier and V-Server Lite V4.0.18.0 and earlier. If a user opens a specially crafted VPR file, information may be disclosed and/or arbitrary code may be executed."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Heap-based buffer overflow",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-15T06:03:46.888Z",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "url": "https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php"
        },
        {
          "url": "https://hakko-elec.co.jp/site/download/03tellus_inf/index.php"
        },
        {
          "url": "https://jvn.jp/en/vu/JVNVU93840158/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2023-47586",
    "datePublished": "2023-11-15T06:03:46.888Z",
    "dateReserved": "2023-11-07T02:41:20.173Z",
    "dateUpdated": "2024-08-29T17:50:00.621Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2018-10637
Vulnerability from cvelistv5
Published
2018-09-13 20:00
Modified
2024-09-17 01:11
Severity ?
Summary
A maliciously crafted project file may cause a buffer overflow, which may allow the attacker to execute arbitrary code that affects Fuji Electric V-Server Lite 4.0.3.0 and prior.
References
Impacted products
Vendor Product Version
Fuji Electric V-Server Lite Version: 4.0.3.0 and prior
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T07:46:47.265Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "105328",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/105328"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server Lite",
          "vendor": "Fuji Electric",
          "versions": [
            {
              "status": "affected",
              "version": "4.0.3.0 and prior"
            }
          ]
        }
      ],
      "datePublic": "2018-09-11T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A maliciously crafted project file may cause a buffer overflow, which may allow the attacker to execute arbitrary code that affects Fuji Electric V-Server Lite 4.0.3.0 and prior."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "BUFFER COPY WITHOUT CHECKING SIZE OF INPUT (\u0027CLASSIC BUFFER OVERFLOW\u0027) CWE-120",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-09-14T09:57:02",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "105328",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/105328"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-09-11T00:00:00",
          "ID": "CVE-2018-10637",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "V-Server Lite",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "4.0.3.0 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Fuji Electric"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A maliciously crafted project file may cause a buffer overflow, which may allow the attacker to execute arbitrary code that affects Fuji Electric V-Server Lite 4.0.3.0 and prior."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "BUFFER COPY WITHOUT CHECKING SIZE OF INPUT (\u0027CLASSIC BUFFER OVERFLOW\u0027) CWE-120"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "105328",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/105328"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-10637",
    "datePublished": "2018-09-13T20:00:00Z",
    "dateReserved": "2018-05-01T00:00:00",
    "dateUpdated": "2024-09-17T01:11:13.766Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-47584
Vulnerability from cvelistv5
Published
2023-11-15 06:03
Modified
2024-08-29 15:15
Severity ?
Summary
Out-of-bounds write vulnerability exists in V-Server V4.0.18.0 and earlier and V-Server Lite V4.0.18.0 and earlier. If a user opens a specially crafted VPR file, information may be disclosed and/or arbitrary code may be executed.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T21:09:37.423Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://hakko-elec.co.jp/site/download/03tellus_inf/index.php"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/vu/JVNVU93840158/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:fujielectric:v-server_lite:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "v-server_lite",
            "vendor": "fujielectric",
            "versions": [
              {
                "lessThan": "V4.0.18.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-47584",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-29T15:14:50.816482Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-29T15:15:45.277Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server",
          "vendor": "FUJI ELECTRIC CO., LTD. and Hakko Electronics Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "V4.0.18.0 and earlier"
            }
          ]
        },
        {
          "product": "V-Server Lite",
          "vendor": "FUJI ELECTRIC CO., LTD. and Hakko Electronics Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "V4.0.18.0 and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Out-of-bounds write vulnerability exists in V-Server V4.0.18.0 and earlier and V-Server Lite V4.0.18.0 and earlier. If a user opens a specially crafted VPR file, information may be disclosed and/or arbitrary code may be executed.\r\n"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Out-of-bounds write",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-15T06:03:19.425Z",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "url": "https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php"
        },
        {
          "url": "https://hakko-elec.co.jp/site/download/03tellus_inf/index.php"
        },
        {
          "url": "https://jvn.jp/en/vu/JVNVU93840158/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2023-47584",
    "datePublished": "2023-11-15T06:03:19.425Z",
    "dateReserved": "2023-11-07T02:41:20.173Z",
    "dateUpdated": "2024-08-29T15:15:45.277Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-47585
Vulnerability from cvelistv5
Published
2023-11-15 06:03
Modified
2024-08-29 15:13
Severity ?
Summary
Out-of-bounds read vulnerability exists in V-Server V4.0.18.0 and earlier and V-Server Lite V4.0.18.0 and earlier. If a user opens a specially crafted VPR file, information may be disclosed and/or arbitrary code may be executed.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T21:09:37.505Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://hakko-elec.co.jp/site/download/03tellus_inf/index.php"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/vu/JVNVU93840158/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:fujielectric:v-server_lite:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "v-server_lite",
            "vendor": "fujielectric",
            "versions": [
              {
                "lessThan": "V4.0.18.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-47585",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-29T15:11:07.366451Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-29T15:13:49.252Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server",
          "vendor": "FUJI ELECTRIC CO., LTD. and Hakko Electronics Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "V4.0.18.0 and earlier"
            }
          ]
        },
        {
          "product": "V-Server Lite",
          "vendor": "FUJI ELECTRIC CO., LTD. and Hakko Electronics Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "V4.0.18.0 and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Out-of-bounds read vulnerability exists in V-Server V4.0.18.0 and earlier and V-Server Lite V4.0.18.0 and earlier. If a user opens a specially crafted VPR file, information may be disclosed and/or arbitrary code may be executed."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Out-of-bounds read",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-15T06:03:31.138Z",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "url": "https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php"
        },
        {
          "url": "https://hakko-elec.co.jp/site/download/03tellus_inf/index.php"
        },
        {
          "url": "https://jvn.jp/en/vu/JVNVU93840158/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2023-47585",
    "datePublished": "2023-11-15T06:03:31.138Z",
    "dateReserved": "2023-11-07T02:41:20.173Z",
    "dateUpdated": "2024-08-29T15:13:49.252Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2018-14813
Vulnerability from cvelistv5
Published
2018-09-26 20:00
Modified
2024-09-17 01:26
Severity ?
Summary
Fuji Electric V-Server 4.0.3.0 and prior, A heap-based buffer overflow vulnerability has been identified, which may allow remote code execution.
References
Impacted products
Vendor Product Version
Fuji Electric V-Server Version: 4.0.3.0 and prior
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T09:38:14.060Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
          },
          {
            "name": "105341",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/105341"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server",
          "vendor": "Fuji Electric",
          "versions": [
            {
              "status": "affected",
              "version": "4.0.3.0 and prior"
            }
          ]
        }
      ],
      "datePublic": "2018-09-11T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric V-Server 4.0.3.0 and prior, A heap-based buffer overflow vulnerability has been identified, which may allow remote code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "HEAP-BASED BUFFER OVERFLOW CWE-122",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-09-27T09:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
        },
        {
          "name": "105341",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/105341"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-09-11T00:00:00",
          "ID": "CVE-2018-14813",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "V-Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "4.0.3.0 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Fuji Electric"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Fuji Electric V-Server 4.0.3.0 and prior, A heap-based buffer overflow vulnerability has been identified, which may allow remote code execution."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "HEAP-BASED BUFFER OVERFLOW CWE-122"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
            },
            {
              "name": "105341",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/105341"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-14813",
    "datePublished": "2018-09-26T20:00:00Z",
    "dateReserved": "2018-08-01T00:00:00",
    "dateUpdated": "2024-09-17T01:26:31.392Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-38401
Vulnerability from cvelistv5
Published
2021-12-20 20:08
Modified
2024-08-04 01:37
Summary
Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an untrusted pointer dereference, which may allow an attacker to execute arbitrary code and cause the application to crash.
References
Impacted products
Vendor Product Version
Fuji Electric V-Server Lite Version: unspecified   < 4.0.12.0
Create a notification for this product.
   Fuji Electric Tellus Lite V-Simulator Version: unspecified   < 4.0.12.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:37:16.513Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server Lite",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Tellus Lite V-Simulator",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an untrusted pointer dereference, which may allow an attacker to execute arbitrary code and cause the application to crash."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-822",
              "description": "CWE-822 - Untrusted pointer dereference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-20T20:08:47",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
        }
      ],
      "source": {
        "advisory": "ICSA-21-299-01",
        "discovery": "EXTERNAL"
      },
      "title": " Fuji Electric Tellus Lite V-Simulator untrusted pointer dereference",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-38401",
          "STATE": "PUBLIC",
          "TITLE": " Fuji Electric Tellus Lite V-Simulator untrusted pointer dereference"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "V-Server Lite",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Tellus Lite V-Simulator",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": " Fuji Electric"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an untrusted pointer dereference, which may allow an attacker to execute arbitrary code and cause the application to crash."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-822 - Untrusted pointer dereference"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
          }
        ],
        "source": {
          "advisory": "ICSA-21-299-01",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-38401",
    "datePublished": "2021-12-20T20:08:47",
    "dateReserved": "2021-08-10T00:00:00",
    "dateUpdated": "2024-08-04T01:37:16.513Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-30549
Vulnerability from cvelistv5
Published
2022-06-16 01:35
Modified
2024-08-03 06:48
Severity ?
Summary
Out-of-bounds read vulnerability exists in V-Server v4.0.11.0 and earlier and V-Server Lite v4.0.13.0 and earlier, which may allow an attacker to obtain information and/or execute arbitrary code by having a user to open a specially crafted image file.
Impacted products
Vendor Product Version
FUJI ELECTRIC CO., LTD. / Hakko Electronics Co., Ltd. V-Server and V-Server Lite Version: V-Server v4.0.11.0 and earlier, and V-Server Lite v4.0.13.0 and earlier
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:48:36.444Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://monitouch.fujielectric.com/site/download-e/09vsft6_inf/Search.php"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://monitouch.fujielectric.com/site/download-eu/03tellus_inf/index.php"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/vu/JVNVU93134398/index.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server and V-Server Lite",
          "vendor": "FUJI ELECTRIC CO., LTD. / Hakko Electronics Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "V-Server v4.0.11.0 and earlier, and V-Server Lite v4.0.13.0 and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Out-of-bounds read vulnerability exists in V-Server v4.0.11.0 and earlier and V-Server Lite v4.0.13.0 and earlier, which may allow an attacker to obtain information and/or execute arbitrary code by having a user to open a specially crafted image file."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Out-of-bounds Read",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-16T01:35:24",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://monitouch.fujielectric.com/site/download-e/09vsft6_inf/Search.php"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://monitouch.fujielectric.com/site/download-eu/03tellus_inf/index.php"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jvn.jp/en/vu/JVNVU93134398/index.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vultures@jpcert.or.jp",
          "ID": "CVE-2022-30549",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "V-Server and V-Server Lite",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "V-Server v4.0.11.0 and earlier, and V-Server Lite v4.0.13.0 and earlier"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "FUJI ELECTRIC CO., LTD. / Hakko Electronics Co., Ltd."
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Out-of-bounds read vulnerability exists in V-Server v4.0.11.0 and earlier and V-Server Lite v4.0.13.0 and earlier, which may allow an attacker to obtain information and/or execute arbitrary code by having a user to open a specially crafted image file."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://monitouch.fujielectric.com/site/download-e/09vsft6_inf/Search.php",
              "refsource": "MISC",
              "url": "https://monitouch.fujielectric.com/site/download-e/09vsft6_inf/Search.php"
            },
            {
              "name": "https://monitouch.fujielectric.com/site/download-eu/03tellus_inf/index.php",
              "refsource": "MISC",
              "url": "https://monitouch.fujielectric.com/site/download-eu/03tellus_inf/index.php"
            },
            {
              "name": "https://jvn.jp/en/vu/JVNVU93134398/index.html",
              "refsource": "MISC",
              "url": "https://jvn.jp/en/vu/JVNVU93134398/index.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2022-30549",
    "datePublished": "2022-06-16T01:35:24",
    "dateReserved": "2022-05-23T00:00:00",
    "dateUpdated": "2024-08-03T06:48:36.444Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2018-14817
Vulnerability from cvelistv5
Published
2018-09-26 20:00
Modified
2024-09-16 22:09
Severity ?
Summary
Fuji Electric V-Server 4.0.3.0 and prior, An integer underflow vulnerability has been identified, which may allow remote code execution.
References
Impacted products
Vendor Product Version
Fuji Electric V-Server Version: 4.0.3.0 and prior
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T09:38:13.911Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
          },
          {
            "name": "105341",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/105341"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server",
          "vendor": "Fuji Electric",
          "versions": [
            {
              "status": "affected",
              "version": "4.0.3.0 and prior"
            }
          ]
        }
      ],
      "datePublic": "2018-09-11T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric V-Server 4.0.3.0 and prior, An integer underflow vulnerability has been identified, which may allow remote code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-191",
              "description": "INTEGER UNDERFLOW CWE-191",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-09-27T09:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
        },
        {
          "name": "105341",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/105341"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-09-11T00:00:00",
          "ID": "CVE-2018-14817",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "V-Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "4.0.3.0 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Fuji Electric"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Fuji Electric V-Server 4.0.3.0 and prior, An integer underflow vulnerability has been identified, which may allow remote code execution."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "INTEGER UNDERFLOW CWE-191"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
            },
            {
              "name": "105341",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/105341"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-14817",
    "datePublished": "2018-09-26T20:00:00Z",
    "dateReserved": "2018-08-01T00:00:00",
    "dateUpdated": "2024-09-16T22:09:53.694Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-38421
Vulnerability from cvelistv5
Published
2021-12-20 20:08
Modified
2024-08-04 01:44
Summary
Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds read, which may allow an attacker to read sensitive information from other memory locations or cause a crash.
References
Impacted products
Vendor Product Version
Fuji Electric V-Server Lite Version: unspecified   < 4.0.12.0
Create a notification for this product.
   Fuji Electric Tellus Lite V-Simulator Version: unspecified   < 4.0.12.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:44:22.159Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server Lite",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Tellus Lite V-Simulator",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds read, which may allow an attacker to read sensitive information from other memory locations or cause a crash."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125 Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-20T20:08:48",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
        }
      ],
      "source": {
        "advisory": "ICSA-21-299-01",
        "discovery": "EXTERNAL"
      },
      "title": " Fuji Electric Tellus Lite V-Simulator out of bounds read",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-38421",
          "STATE": "PUBLIC",
          "TITLE": " Fuji Electric Tellus Lite V-Simulator out of bounds read"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "V-Server Lite",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Tellus Lite V-Simulator",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": " Fuji Electric"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds read, which may allow an attacker to read sensitive information from other memory locations or cause a crash."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-125 Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
          }
        ],
        "source": {
          "advisory": "ICSA-21-299-01",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-38421",
    "datePublished": "2021-12-20T20:08:48",
    "dateReserved": "2021-08-10T00:00:00",
    "dateUpdated": "2024-08-04T01:44:22.159Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-3947
Vulnerability from cvelistv5
Published
2019-06-12 14:06
Modified
2024-08-04 19:26
Severity ?
Summary
Fuji Electric V-Server before 6.0.33.0 stores database credentials in project files as plaintext. An attacker that can gain access to the project file can recover the database credentials and gain access to the database server.
References
Impacted products
Vendor Product Version
n/a Fuji Electric V-Server Version: Versions prior to 6.0.33.0
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T19:26:27.750Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.tenable.com/security/research/tra-2019-27"
          },
          {
            "name": "108740",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/108740"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Fuji Electric V-Server",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Versions prior to 6.0.33.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric V-Server before 6.0.33.0 stores database credentials in project files as plaintext. An attacker that can gain access to the project file can recover the database credentials and gain access to the database server."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Plaintext storage of credentials",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-06-13T11:06:07",
        "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "shortName": "tenable"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.tenable.com/security/research/tra-2019-27"
        },
        {
          "name": "108740",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/108740"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vulnreport@tenable.com",
          "ID": "CVE-2019-3947",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Fuji Electric V-Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Versions prior to 6.0.33.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Fuji Electric V-Server before 6.0.33.0 stores database credentials in project files as plaintext. An attacker that can gain access to the project file can recover the database credentials and gain access to the database server."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Plaintext storage of credentials"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.tenable.com/security/research/tra-2019-27",
              "refsource": "MISC",
              "url": "https://www.tenable.com/security/research/tra-2019-27"
            },
            {
              "name": "108740",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/108740"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
    "assignerShortName": "tenable",
    "cveId": "CVE-2019-3947",
    "datePublished": "2019-06-12T14:06:57",
    "dateReserved": "2019-01-03T00:00:00",
    "dateUpdated": "2024-08-04T19:26:27.750Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-47908
Vulnerability from cvelistv5
Published
2023-01-03 00:00
Modified
2024-08-03 15:02
Severity ?
Summary
Stack-based buffer overflow vulnerability in V-Server v4.0.12.0 and earlier allows a local attacker to obtain the information and/or execute arbitrary code by having a user to open a specially crafted project file.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T15:02:36.472Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/vu/JVNVU92811888/index.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server",
          "vendor": "FUJI ELECTRIC CO., LTD. and Hakko Electronics Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "v4.0.12.0 and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Stack-based buffer overflow vulnerability in V-Server v4.0.12.0 and earlier allows a local attacker to obtain the information and/or execute arbitrary code by having a user to open a specially crafted project file."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-01-03T00:00:00",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "url": "https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php"
        },
        {
          "url": "https://jvn.jp/en/vu/JVNVU92811888/index.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2022-47908",
    "datePublished": "2023-01-03T00:00:00",
    "dateReserved": "2022-12-26T00:00:00",
    "dateUpdated": "2024-08-03T15:02:36.472Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-29522
Vulnerability from cvelistv5
Published
2022-06-14 07:05
Modified
2024-08-03 06:26
Severity ?
Summary
Use after free vulnerability exists in the simulator module contained in the graphic editor 'V-SFT' versions prior to v6.1.6.0, which may allow an attacker to obtain information and/or execute arbitrary code by having a user to open a specially crafted image file.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:26:06.350Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://monitouch.fujielectric.com/site/download-e/09vsft6_inf/Search.php"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/vu/JVNVU99188133/index.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-SFT",
          "vendor": "FUJI ELECTRIC CO., LTD. / Hakko Electronics Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "versions prior to v6.1.6.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Use after free vulnerability exists in the simulator module contained in the graphic editor \u0027V-SFT\u0027 versions prior to v6.1.6.0, which may allow an attacker to obtain information and/or execute arbitrary code by having a user to open a specially crafted image file."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Use After Free",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-14T07:05:44",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://monitouch.fujielectric.com/site/download-e/09vsft6_inf/Search.php"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jvn.jp/en/vu/JVNVU99188133/index.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vultures@jpcert.or.jp",
          "ID": "CVE-2022-29522",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "V-SFT",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "versions prior to v6.1.6.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "FUJI ELECTRIC CO., LTD. / Hakko Electronics Co., Ltd."
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Use after free vulnerability exists in the simulator module contained in the graphic editor \u0027V-SFT\u0027 versions prior to v6.1.6.0, which may allow an attacker to obtain information and/or execute arbitrary code by having a user to open a specially crafted image file."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Use After Free"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://monitouch.fujielectric.com/site/download-e/09vsft6_inf/Search.php",
              "refsource": "MISC",
              "url": "https://monitouch.fujielectric.com/site/download-e/09vsft6_inf/Search.php"
            },
            {
              "name": "https://jvn.jp/en/vu/JVNVU99188133/index.html",
              "refsource": "MISC",
              "url": "https://jvn.jp/en/vu/JVNVU99188133/index.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2022-29522",
    "datePublished": "2022-06-14T07:05:44",
    "dateReserved": "2022-05-12T00:00:00",
    "dateUpdated": "2024-08-03T06:26:06.350Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-3946
Vulnerability from cvelistv5
Published
2019-06-12 14:06
Modified
2024-08-04 19:26
Severity ?
Summary
Fuji Electric V-Server before 6.0.33.0 is vulnerable to denial of service via a crafted UDP message sent to port 8005. An unauthenticated, remote attacker can crash vserver.exe due to an integer overflow in the UDP message handling logic.
References
Impacted products
Vendor Product Version
n/a Fuji Electric V-Server Version: Versions prior to 6.0.33.0
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T19:26:27.278Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.tenable.com/security/research/tra-2019-27"
          },
          {
            "name": "108740",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/108740"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Fuji Electric V-Server",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Versions prior to 6.0.33.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric V-Server before 6.0.33.0 is vulnerable to denial of service via a crafted UDP message sent to port 8005. An unauthenticated, remote attacker can crash vserver.exe due to an integer overflow in the UDP message handling logic."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Denial of Service",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-06-13T11:06:07",
        "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "shortName": "tenable"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.tenable.com/security/research/tra-2019-27"
        },
        {
          "name": "108740",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/108740"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vulnreport@tenable.com",
          "ID": "CVE-2019-3946",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Fuji Electric V-Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Versions prior to 6.0.33.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Fuji Electric V-Server before 6.0.33.0 is vulnerable to denial of service via a crafted UDP message sent to port 8005. An unauthenticated, remote attacker can crash vserver.exe due to an integer overflow in the UDP message handling logic."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Denial of Service"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.tenable.com/security/research/tra-2019-27",
              "refsource": "MISC",
              "url": "https://www.tenable.com/security/research/tra-2019-27"
            },
            {
              "name": "108740",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/108740"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
    "assignerShortName": "tenable",
    "cveId": "CVE-2019-3946",
    "datePublished": "2019-06-12T14:06:52",
    "dateReserved": "2019-01-03T00:00:00",
    "dateUpdated": "2024-08-04T19:26:27.278Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-22655
Vulnerability from cvelistv5
Published
2021-01-27 19:06
Modified
2024-08-03 18:51
Severity ?
Summary
Multiple out-of-bounds read issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0).
References
Impacted products
Vendor Product Version
n/a Tellus Lite V-Simulator and V-Server Lite Version: Versions prior to 4.0.10.0
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:51:06.042Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Tellus Lite V-Simulator and V-Server Lite",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Versions prior to 4.0.10.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Multiple out-of-bounds read issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0)."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "OUT-OF-BOUNDS READ CWE-125",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-01-27T19:06:42",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-22655",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Tellus Lite V-Simulator and V-Server Lite",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Versions prior to 4.0.10.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Multiple out-of-bounds read issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0)."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "OUT-OF-BOUNDS READ CWE-125"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-22655",
    "datePublished": "2021-01-27T19:06:42",
    "dateReserved": "2021-01-05T00:00:00",
    "dateUpdated": "2024-08-03T18:51:06.042Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-41645
Vulnerability from cvelistv5
Published
2023-01-03 00:00
Modified
2024-08-03 12:49
Severity ?
Summary
Out-of-bounds read vulnerability in V-Server v4.0.12.0 and earlier allows a local attacker to obtain the information and/or execute arbitrary code by having a user to open a specially crafted project file.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T12:49:43.359Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/vu/JVNVU92811888/index.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server",
          "vendor": "FUJI ELECTRIC CO., LTD. and Hakko Electronics Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "v4.0.12.0 and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Out-of-bounds read vulnerability in V-Server v4.0.12.0 and earlier allows a local attacker to obtain the information and/or execute arbitrary code by having a user to open a specially crafted project file."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Out-of-bounds Read",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-01-03T00:00:00",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "url": "https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php"
        },
        {
          "url": "https://jvn.jp/en/vu/JVNVU92811888/index.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2022-41645",
    "datePublished": "2023-01-03T00:00:00",
    "dateReserved": "2022-12-26T00:00:00",
    "dateUpdated": "2024-08-03T12:49:43.359Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2020-10646
Vulnerability from cvelistv5
Published
2020-04-13 18:50
Modified
2024-08-04 11:06
Severity ?
Summary
Fuji Electric V-Server Lite all versions prior to 4.0.9.0 contains a heap based buffer overflow. The buffer allocated to read data, when parsing VPR files, is too small.
References
Impacted products
Vendor Product Version
n/a Fuji Electric V-Server Lite all versions prior to 4.0.9.0 Version: Fuji Electric V-Server Lite all versions prior to 4.0.9.0
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:06:10.554Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-20-098-04"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Fuji Electric V-Server Lite all versions prior to 4.0.9.0",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Fuji Electric V-Server Lite all versions prior to 4.0.9.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric V-Server Lite all versions prior to 4.0.9.0 contains a heap based buffer overflow. The buffer allocated to read data, when parsing VPR files, is too small."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "HEAP-BASED BUFFER OVERFLOW CWE-122",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-04-13T18:50:27",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-098-04"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-10646",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Fuji Electric V-Server Lite all versions prior to 4.0.9.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Fuji Electric V-Server Lite all versions prior to 4.0.9.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Fuji Electric V-Server Lite all versions prior to 4.0.9.0 contains a heap based buffer overflow. The buffer allocated to read data, when parsing VPR files, is too small."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "HEAP-BASED BUFFER OVERFLOW CWE-122"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-20-098-04",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-098-04"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-10646",
    "datePublished": "2020-04-13T18:50:27",
    "dateReserved": "2020-03-16T00:00:00",
    "dateUpdated": "2024-08-04T11:06:10.554Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-22639
Vulnerability from cvelistv5
Published
2021-01-27 19:05
Modified
2024-08-03 18:44
Severity ?
Summary
An uninitialized pointer issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0).
Impacted products
Vendor Product Version
n/a Tellus Lite V-Simulator and V-Server Lite Version: Versions prior to 4.0.10.0
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:44:14.040Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-098/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Tellus Lite V-Simulator and V-Server Lite",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Versions prior to 4.0.10.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An uninitialized pointer issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0)."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-824",
              "description": "ACCESS OF UNINITIALIZED POINTER CWE-824",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-01-29T07:06:35",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-098/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-22639",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Tellus Lite V-Simulator and V-Server Lite",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Versions prior to 4.0.10.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An uninitialized pointer issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0)."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "ACCESS OF UNINITIALIZED POINTER CWE-824"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
            },
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-098/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-098/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-22639",
    "datePublished": "2021-01-27T19:05:19",
    "dateReserved": "2021-01-05T00:00:00",
    "dateUpdated": "2024-08-03T18:44:14.040Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2017-9639
Vulnerability from cvelistv5
Published
2017-07-17 19:00
Modified
2024-08-05 17:11
Severity ?
Summary
An issue was discovered in Fuji Electric V-Server Version 3.3.22.0 and prior. A memory corruption vulnerability has been identified (aka improper restriction of operations within the bounds of a memory buffer), which may allow remote code execution.
References
Impacted products
Vendor Product Version
n/a Fuji Electric V-Server Version: Fuji Electric V-Server
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T17:11:02.361Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-192-02"
          },
          {
            "name": "99544",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/99544"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Fuji Electric V-Server",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Fuji Electric V-Server"
            }
          ]
        }
      ],
      "datePublic": "2017-07-17T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in Fuji Electric V-Server Version 3.3.22.0 and prior. A memory corruption vulnerability has been identified (aka improper restriction of operations within the bounds of a memory buffer), which may allow remote code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "CWE-119",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-07-18T09:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-192-02"
        },
        {
          "name": "99544",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/99544"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-9639",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Fuji Electric V-Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Fuji Electric V-Server"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered in Fuji Electric V-Server Version 3.3.22.0 and prior. A memory corruption vulnerability has been identified (aka improper restriction of operations within the bounds of a memory buffer), which may allow remote code execution."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-119"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-192-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-192-02"
            },
            {
              "name": "99544",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/99544"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-9639",
    "datePublished": "2017-07-17T19:00:00",
    "dateReserved": "2017-06-14T00:00:00",
    "dateUpdated": "2024-08-05T17:11:02.361Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-38409
Vulnerability from cvelistv5
Published
2021-12-20 20:08
Modified
2024-08-04 01:37
Summary
Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an access of uninitialized pointer, which may allow an attacker read from or write to unexpected memory locations, leading to a denial-of-service.
References
Impacted products
Vendor Product Version
Fuji Electric V-Server Lite Version: unspecified   < 4.0.12.0
Create a notification for this product.
   Fuji Electric Tellus Lite V-Simulator Version: unspecified   < 4.0.12.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:37:16.652Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server Lite",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Tellus Lite V-Simulator",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an access of uninitialized pointer, which may allow an attacker read from or write to unexpected memory locations, leading to a denial-of-service."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-824",
              "description": "CWE-824 Access of Uninitialized Pointer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-20T20:08:46",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
        }
      ],
      "source": {
        "advisory": "ICSA-21-299-01",
        "discovery": "EXTERNAL"
      },
      "title": " Fuji Electric Tellus Lite V-Simulator uninitialized pointer",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-38409",
          "STATE": "PUBLIC",
          "TITLE": " Fuji Electric Tellus Lite V-Simulator uninitialized pointer"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "V-Server Lite",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Tellus Lite V-Simulator",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": " Fuji Electric"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an access of uninitialized pointer, which may allow an attacker read from or write to unexpected memory locations, leading to a denial-of-service."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-824 Access of Uninitialized Pointer"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
          }
        ],
        "source": {
          "advisory": "ICSA-21-299-01",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-38409",
    "datePublished": "2021-12-20T20:08:46",
    "dateReserved": "2021-08-10T00:00:00",
    "dateUpdated": "2024-08-04T01:37:16.652Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2018-14823
Vulnerability from cvelistv5
Published
2018-09-26 20:00
Modified
2024-09-17 02:16
Severity ?
Summary
Fuji Electric V-Server 4.0.3.0 and prior, A stack-based buffer overflow vulnerability has been identified, which may allow remote code execution.
References
Impacted products
Vendor Product Version
Fuji Electric V-Server Version: 4.0.3.0 and prior
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T09:38:13.957Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
          },
          {
            "name": "105341",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/105341"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server",
          "vendor": "Fuji Electric",
          "versions": [
            {
              "status": "affected",
              "version": "4.0.3.0 and prior"
            }
          ]
        }
      ],
      "datePublic": "2018-09-11T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric V-Server 4.0.3.0 and prior, A stack-based buffer overflow vulnerability has been identified, which may allow remote code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "STACK-BASED BUFFER OVERFLOW CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-09-27T09:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
        },
        {
          "name": "105341",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/105341"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-09-11T00:00:00",
          "ID": "CVE-2018-14823",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "V-Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "4.0.3.0 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Fuji Electric"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Fuji Electric V-Server 4.0.3.0 and prior, A stack-based buffer overflow vulnerability has been identified, which may allow remote code execution."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "STACK-BASED BUFFER OVERFLOW CWE-121"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-01"
            },
            {
              "name": "105341",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/105341"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-14823",
    "datePublished": "2018-09-26T20:00:00Z",
    "dateReserved": "2018-08-01T00:00:00",
    "dateUpdated": "2024-09-17T02:16:13.438Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-22641
Vulnerability from cvelistv5
Published
2021-01-27 19:03
Modified
2024-08-03 18:44
Severity ?
Summary
A heap-based buffer overflow issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0).
Impacted products
Vendor Product Version
n/a Tellus Lite V-Simulator and V-Server Lite Version: Versions prior to 4.0.10.0
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:44:13.855Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-099/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Tellus Lite V-Simulator and V-Server Lite",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Versions prior to 4.0.10.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A heap-based buffer overflow issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0)."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "HEAP-BASED BUFFER OVERFLOW CWE-122",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-01-29T07:06:35",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-099/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-22641",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Tellus Lite V-Simulator and V-Server Lite",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Versions prior to 4.0.10.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A heap-based buffer overflow issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0)."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "HEAP-BASED BUFFER OVERFLOW CWE-122"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
            },
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-099/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-099/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-22641",
    "datePublished": "2021-01-27T19:03:41",
    "dateReserved": "2021-01-05T00:00:00",
    "dateUpdated": "2024-08-03T18:44:13.855Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",