    CVE-2019-12948 (GCVE-0-2019-12948)

    Vulnerability from cvelistv5 – Published: 2019-07-29 15:16 – Updated: 2024-08-04 23:32
    VLAI
    Summary
    A vulnerability in the web-based management interface of VVX, Trio, SoundStructure, SoundPoint, and SoundStation phones running Polycom UC Software, if exploited, could allow an authenticated, remote attacker with admin privileges to cause a denial of service (DoS) condition or execute arbitrary code.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T23:32:55.646Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://support.polycom.com/content/dam/polycom-support/global/documentation/remote-code-execution-vulnerability-in-ucs-software-v1-1.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability in the web-based management interface of VVX, Trio, SoundStructure, SoundPoint, and SoundStation phones running Polycom UC Software, if exploited, could allow an authenticated, remote attacker with admin privileges to cause a denial of service (DoS) condition or execute arbitrary code."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-08-02T20:40:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://support.polycom.com/content/dam/polycom-support/global/documentation/remote-code-execution-vulnerability-in-ucs-software-v1-1.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-12948",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability in the web-based management interface of VVX, Trio, SoundStructure, SoundPoint, and SoundStation phones running Polycom UC Software, if exploited, could allow an authenticated, remote attacker with admin privileges to cause a denial of service (DoS) condition or execute arbitrary code."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://support.polycom.com/content/dam/polycom-support/global/documentation/remote-code-execution-vulnerability-in-ucs-software-v1-1.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://support.polycom.com/content/dam/polycom-support/global/documentation/remote-code-execution-vulnerability-in-ucs-software-v1-1.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-12948",
        "datePublished": "2019-07-29T15:16:41.000Z",
        "dateReserved": "2019-06-24T00:00:00.000Z",
        "dateUpdated": "2024-08-04T23:32:55.646Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-10689 (GCVE-0-2019-10689)

    Vulnerability from cvelistv5 – Published: 2019-06-24 21:10 – Updated: 2024-08-04 22:32
    VLAI
    Summary
    VVX products using UCS software version 5.9.2 and earlier with Better Together over Ethernet Connector (BToE) application version 3.9.1 and earlier provides insufficient authentication between the BToE application and the BToE component, resulting in leakage of sensitive information.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2019-06-18 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T22:32:01.063Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "108799",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/108799"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://support.polycom.com/content/dam/polycom-support/global/documentation/insufficient-authentication-leakage-vvx-products.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2019-06-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "VVX products using UCS software version 5.9.2 and earlier with Better Together over Ethernet Connector (BToE) application version 3.9.1 and earlier provides insufficient authentication between the BToE application and the BToE component, resulting in leakage of sensitive information."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-06-24T21:11:17.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "name": "108799",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/108799"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://support.polycom.com/content/dam/polycom-support/global/documentation/insufficient-authentication-leakage-vvx-products.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-10689",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "VVX products using UCS software version 5.9.2 and earlier with Better Together over Ethernet Connector (BToE) application version 3.9.1 and earlier provides insufficient authentication between the BToE application and the BToE component, resulting in leakage of sensitive information."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "108799",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/108799"
                },
                {
                  "name": "https://support.polycom.com/content/dam/polycom-support/global/documentation/insufficient-authentication-leakage-vvx-products.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://support.polycom.com/content/dam/polycom-support/global/documentation/insufficient-authentication-leakage-vvx-products.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-10689",
        "datePublished": "2019-06-24T21:10:20.000Z",
        "dateReserved": "2019-04-01T00:00:00.000Z",
        "dateUpdated": "2024-08-04T22:32:01.063Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-10688 (GCVE-0-2019-10688)

    Vulnerability from cvelistv5 – Published: 2019-04-23 20:58 – Updated: 2024-08-04 22:32
    VLAI
    Summary
    VVX products with software versions including and prior to, UCS 5.9.2 with Better Together over Ethernet Connector (BToE) application 3.9.1, use hard-coded credentials to establish connections between the host application and the device.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2019-04-23 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T22:32:01.168Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://support.polycom.com/content/dam/polycom-support/global/documentation/hard-coded-credentials-vulnerability-in-vvx-products.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2019-04-23T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "VVX products with software versions including and prior to, UCS 5.9.2 with Better Together over Ethernet Connector (BToE) application 3.9.1, use hard-coded credentials to establish connections between the host application and the device."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-06-17T15:35:35.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://support.polycom.com/content/dam/polycom-support/global/documentation/hard-coded-credentials-vulnerability-in-vvx-products.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-10688",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "VVX products with software versions including and prior to, UCS 5.9.2 with Better Together over Ethernet Connector (BToE) application 3.9.1, use hard-coded credentials to establish connections between the host application and the device."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://support.polycom.com/content/dam/polycom-support/global/documentation/hard-coded-credentials-vulnerability-in-vvx-products.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://support.polycom.com/content/dam/polycom-support/global/documentation/hard-coded-credentials-vulnerability-in-vvx-products.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-10688",
        "datePublished": "2019-04-23T20:58:29.000Z",
        "dateReserved": "2019-04-01T00:00:00.000Z",
        "dateUpdated": "2024-08-04T22:32:01.168Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-18566 (GCVE-0-2018-18566)

    Vulnerability from cvelistv5 – Published: 2018-10-24 22:00 – Updated: 2024-08-05 11:15
    VLAI
    Summary
    The SIP service in Polycom VVX 500 and 601 devices 5.8.0.12848 and earlier allow remote attackers to obtain sensitive phone configuration information by leveraging use with an on-premise installation with Skype for Business.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2018-10-23 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T11:15:59.629Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2018-028.txt"
              },
              {
                "name": "105746",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/105746"
              },
              {
                "name": "20181023 [SYSS-2018-028] information leakage with Polycom VVX Phones (Skype for Business, on-premise) - CVE-2018-18566",
                "tags": [
                  "mailing-list",
                  "x_refsource_BUGTRAQ",
                  "x_transferred"
                ],
                "url": "https://seclists.org/bugtraq/2018/Oct/33"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-10-23T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The SIP service in Polycom VVX 500 and 601 devices 5.8.0.12848 and earlier allow remote attackers to obtain sensitive phone configuration information by leveraging use with an on-premise installation with Skype for Business."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-10-30T09:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2018-028.txt"
            },
            {
              "name": "105746",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/105746"
            },
            {
              "name": "20181023 [SYSS-2018-028] information leakage with Polycom VVX Phones (Skype for Business, on-premise) - CVE-2018-18566",
              "tags": [
                "mailing-list",
                "x_refsource_BUGTRAQ"
              ],
              "url": "https://seclists.org/bugtraq/2018/Oct/33"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-18566",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The SIP service in Polycom VVX 500 and 601 devices 5.8.0.12848 and earlier allow remote attackers to obtain sensitive phone configuration information by leveraging use with an on-premise installation with Skype for Business."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2018-028.txt",
                  "refsource": "MISC",
                  "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2018-028.txt"
                },
                {
                  "name": "105746",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/105746"
                },
                {
                  "name": "20181023 [SYSS-2018-028] information leakage with Polycom VVX Phones (Skype for Business, on-premise) - CVE-2018-18566",
                  "refsource": "BUGTRAQ",
                  "url": "https://seclists.org/bugtraq/2018/Oct/33"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-18566",
        "datePublished": "2018-10-24T22:00:00.000Z",
        "dateReserved": "2018-10-22T00:00:00.000Z",
        "dateUpdated": "2024-08-05T11:15:59.629Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-18568 (GCVE-0-2018-18568)

    Vulnerability from cvelistv5 – Published: 2018-10-24 22:00 – Updated: 2024-08-05 11:15
    VLAI
    Summary
    Polycom VVX 500 and 601 devices 5.8.0.12848 and earlier allows man-in-the-middle attackers to obtain sensitive credential information by leveraging failure to validate X.509 certificates when used with an on-premise installation with Skype for Business.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2018-10-23 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T11:15:59.735Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2018-027.txt"
              },
              {
                "name": "20181023 [SYSS-2018-027] missing X.509 validation with Polycom VVX Phones (Skype for Business, on-premise) - CVE-2018-18568",
                "tags": [
                  "mailing-list",
                  "x_refsource_BUGTRAQ",
                  "x_transferred"
                ],
                "url": "https://seclists.org/bugtraq/2018/Oct/36"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-10-23T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Polycom VVX 500 and 601 devices 5.8.0.12848 and earlier allows man-in-the-middle attackers to obtain sensitive credential information by leveraging failure to validate X.509 certificates when used with an on-premise installation with Skype for Business."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-10-24T21:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2018-027.txt"
            },
            {
              "name": "20181023 [SYSS-2018-027] missing X.509 validation with Polycom VVX Phones (Skype for Business, on-premise) - CVE-2018-18568",
              "tags": [
                "mailing-list",
                "x_refsource_BUGTRAQ"
              ],
              "url": "https://seclists.org/bugtraq/2018/Oct/36"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-18568",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Polycom VVX 500 and 601 devices 5.8.0.12848 and earlier allows man-in-the-middle attackers to obtain sensitive credential information by leveraging failure to validate X.509 certificates when used with an on-premise installation with Skype for Business."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2018-027.txt",
                  "refsource": "MISC",
                  "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2018-027.txt"
                },
                {
                  "name": "20181023 [SYSS-2018-027] missing X.509 validation with Polycom VVX Phones (Skype for Business, on-premise) - CVE-2018-18568",
                  "refsource": "BUGTRAQ",
                  "url": "https://seclists.org/bugtraq/2018/Oct/36"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-18568",
        "datePublished": "2018-10-24T22:00:00.000Z",
        "dateReserved": "2018-10-22T00:00:00.000Z",
        "dateUpdated": "2024-08-05T11:15:59.735Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2017-12857 (GCVE-0-2017-12857)

    Vulnerability from cvelistv5 – Published: 2017-08-25 19:00 – Updated: 2024-08-05 18:51
    VLAI
    Summary
    Polycom SoundStation IP, VVX, and RealPresence Trio that are running software older than UCS 4.0.12, 5.4.5 rev AG, 5.4.7, 5.5.2, or 5.6.0 are affected by a vulnerability in their UCS web application. This vulnerability could allow an authenticated remote attacker to read a segment of the phone's memory which could contain an administrator's password or other sensitive information.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    URL Tags
    http://www.securitytracker.com/id/1039309 vdb-entryx_refsource_SECTRACK
    http://support.polycom.com/content/dam/polycom-su… x_refsource_CONFIRM
    Date Public
    2017-08-25 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T18:51:06.775Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "1039309",
                "tags": [
                  "vdb-entry",
                  "x_refsource_SECTRACK",
                  "x_transferred"
                ],
                "url": "http://www.securitytracker.com/id/1039309"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://support.polycom.com/content/dam/polycom-support/global/documentation/security-advisory-information-disclosure-on-polycom-voice-products-v1.0.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2017-08-25T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Polycom SoundStation IP, VVX, and RealPresence Trio that are running software older than UCS 4.0.12, 5.4.5 rev AG, 5.4.7, 5.5.2, or 5.6.0 are affected by a vulnerability in their UCS web application. This vulnerability could allow an authenticated remote attacker to read a segment of the phone\u0027s memory which could contain an administrator\u0027s password or other sensitive information."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-09-12T09:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "name": "1039309",
              "tags": [
                "vdb-entry",
                "x_refsource_SECTRACK"
              ],
              "url": "http://www.securitytracker.com/id/1039309"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://support.polycom.com/content/dam/polycom-support/global/documentation/security-advisory-information-disclosure-on-polycom-voice-products-v1.0.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2017-12857",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Polycom SoundStation IP, VVX, and RealPresence Trio that are running software older than UCS 4.0.12, 5.4.5 rev AG, 5.4.7, 5.5.2, or 5.6.0 are affected by a vulnerability in their UCS web application. This vulnerability could allow an authenticated remote attacker to read a segment of the phone\u0027s memory which could contain an administrator\u0027s password or other sensitive information."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "1039309",
                  "refsource": "SECTRACK",
                  "url": "http://www.securitytracker.com/id/1039309"
                },
                {
                  "name": "http://support.polycom.com/content/dam/polycom-support/global/documentation/security-advisory-information-disclosure-on-polycom-voice-products-v1.0.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://support.polycom.com/content/dam/polycom-support/global/documentation/security-advisory-information-disclosure-on-polycom-voice-products-v1.0.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2017-12857",
        "datePublished": "2017-08-25T19:00:00.000Z",
        "dateReserved": "2017-08-15T00:00:00.000Z",
        "dateUpdated": "2024-08-05T18:51:06.775Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-12948 (GCVE-0-2019-12948)

    Vulnerability from nvd – Published: 2019-07-29 15:16 – Updated: 2024-08-04 23:32
    VLAI
    Summary
    A vulnerability in the web-based management interface of VVX, Trio, SoundStructure, SoundPoint, and SoundStation phones running Polycom UC Software, if exploited, could allow an authenticated, remote attacker with admin privileges to cause a denial of service (DoS) condition or execute arbitrary code.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T23:32:55.646Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://support.polycom.com/content/dam/polycom-support/global/documentation/remote-code-execution-vulnerability-in-ucs-software-v1-1.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability in the web-based management interface of VVX, Trio, SoundStructure, SoundPoint, and SoundStation phones running Polycom UC Software, if exploited, could allow an authenticated, remote attacker with admin privileges to cause a denial of service (DoS) condition or execute arbitrary code."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-08-02T20:40:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://support.polycom.com/content/dam/polycom-support/global/documentation/remote-code-execution-vulnerability-in-ucs-software-v1-1.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-12948",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability in the web-based management interface of VVX, Trio, SoundStructure, SoundPoint, and SoundStation phones running Polycom UC Software, if exploited, could allow an authenticated, remote attacker with admin privileges to cause a denial of service (DoS) condition or execute arbitrary code."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://support.polycom.com/content/dam/polycom-support/global/documentation/remote-code-execution-vulnerability-in-ucs-software-v1-1.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://support.polycom.com/content/dam/polycom-support/global/documentation/remote-code-execution-vulnerability-in-ucs-software-v1-1.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-12948",
        "datePublished": "2019-07-29T15:16:41.000Z",
        "dateReserved": "2019-06-24T00:00:00.000Z",
        "dateUpdated": "2024-08-04T23:32:55.646Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-10689 (GCVE-0-2019-10689)

    Vulnerability from nvd – Published: 2019-06-24 21:10 – Updated: 2024-08-04 22:32
    VLAI
    Summary
    VVX products using UCS software version 5.9.2 and earlier with Better Together over Ethernet Connector (BToE) application version 3.9.1 and earlier provides insufficient authentication between the BToE application and the BToE component, resulting in leakage of sensitive information.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2019-06-18 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T22:32:01.063Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "108799",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/108799"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://support.polycom.com/content/dam/polycom-support/global/documentation/insufficient-authentication-leakage-vvx-products.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2019-06-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "VVX products using UCS software version 5.9.2 and earlier with Better Together over Ethernet Connector (BToE) application version 3.9.1 and earlier provides insufficient authentication between the BToE application and the BToE component, resulting in leakage of sensitive information."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-06-24T21:11:17.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "name": "108799",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/108799"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://support.polycom.com/content/dam/polycom-support/global/documentation/insufficient-authentication-leakage-vvx-products.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-10689",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "VVX products using UCS software version 5.9.2 and earlier with Better Together over Ethernet Connector (BToE) application version 3.9.1 and earlier provides insufficient authentication between the BToE application and the BToE component, resulting in leakage of sensitive information."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "108799",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/108799"
                },
                {
                  "name": "https://support.polycom.com/content/dam/polycom-support/global/documentation/insufficient-authentication-leakage-vvx-products.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://support.polycom.com/content/dam/polycom-support/global/documentation/insufficient-authentication-leakage-vvx-products.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-10689",
        "datePublished": "2019-06-24T21:10:20.000Z",
        "dateReserved": "2019-04-01T00:00:00.000Z",
        "dateUpdated": "2024-08-04T22:32:01.063Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-10688 (GCVE-0-2019-10688)

    Vulnerability from nvd – Published: 2019-04-23 20:58 – Updated: 2024-08-04 22:32
    VLAI
    Summary
    VVX products with software versions including and prior to, UCS 5.9.2 with Better Together over Ethernet Connector (BToE) application 3.9.1, use hard-coded credentials to establish connections between the host application and the device.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2019-04-23 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T22:32:01.168Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://support.polycom.com/content/dam/polycom-support/global/documentation/hard-coded-credentials-vulnerability-in-vvx-products.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2019-04-23T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "VVX products with software versions including and prior to, UCS 5.9.2 with Better Together over Ethernet Connector (BToE) application 3.9.1, use hard-coded credentials to establish connections between the host application and the device."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-06-17T15:35:35.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://support.polycom.com/content/dam/polycom-support/global/documentation/hard-coded-credentials-vulnerability-in-vvx-products.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-10688",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "VVX products with software versions including and prior to, UCS 5.9.2 with Better Together over Ethernet Connector (BToE) application 3.9.1, use hard-coded credentials to establish connections between the host application and the device."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://support.polycom.com/content/dam/polycom-support/global/documentation/hard-coded-credentials-vulnerability-in-vvx-products.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://support.polycom.com/content/dam/polycom-support/global/documentation/hard-coded-credentials-vulnerability-in-vvx-products.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-10688",
        "datePublished": "2019-04-23T20:58:29.000Z",
        "dateReserved": "2019-04-01T00:00:00.000Z",
        "dateUpdated": "2024-08-04T22:32:01.168Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-18566 (GCVE-0-2018-18566)

    Vulnerability from nvd – Published: 2018-10-24 22:00 – Updated: 2024-08-05 11:15
    VLAI
    Summary
    The SIP service in Polycom VVX 500 and 601 devices 5.8.0.12848 and earlier allow remote attackers to obtain sensitive phone configuration information by leveraging use with an on-premise installation with Skype for Business.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2018-10-23 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T11:15:59.629Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2018-028.txt"
              },
              {
                "name": "105746",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/105746"
              },
              {
                "name": "20181023 [SYSS-2018-028] information leakage with Polycom VVX Phones (Skype for Business, on-premise) - CVE-2018-18566",
                "tags": [
                  "mailing-list",
                  "x_refsource_BUGTRAQ",
                  "x_transferred"
                ],
                "url": "https://seclists.org/bugtraq/2018/Oct/33"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-10-23T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The SIP service in Polycom VVX 500 and 601 devices 5.8.0.12848 and earlier allow remote attackers to obtain sensitive phone configuration information by leveraging use with an on-premise installation with Skype for Business."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-10-30T09:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2018-028.txt"
            },
            {
              "name": "105746",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/105746"
            },
            {
              "name": "20181023 [SYSS-2018-028] information leakage with Polycom VVX Phones (Skype for Business, on-premise) - CVE-2018-18566",
              "tags": [
                "mailing-list",
                "x_refsource_BUGTRAQ"
              ],
              "url": "https://seclists.org/bugtraq/2018/Oct/33"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-18566",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The SIP service in Polycom VVX 500 and 601 devices 5.8.0.12848 and earlier allow remote attackers to obtain sensitive phone configuration information by leveraging use with an on-premise installation with Skype for Business."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2018-028.txt",
                  "refsource": "MISC",
                  "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2018-028.txt"
                },
                {
                  "name": "105746",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/105746"
                },
                {
                  "name": "20181023 [SYSS-2018-028] information leakage with Polycom VVX Phones (Skype for Business, on-premise) - CVE-2018-18566",
                  "refsource": "BUGTRAQ",
                  "url": "https://seclists.org/bugtraq/2018/Oct/33"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-18566",
        "datePublished": "2018-10-24T22:00:00.000Z",
        "dateReserved": "2018-10-22T00:00:00.000Z",
        "dateUpdated": "2024-08-05T11:15:59.629Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-18568 (GCVE-0-2018-18568)

    Vulnerability from nvd – Published: 2018-10-24 22:00 – Updated: 2024-08-05 11:15
    VLAI
    Summary
    Polycom VVX 500 and 601 devices 5.8.0.12848 and earlier allows man-in-the-middle attackers to obtain sensitive credential information by leveraging failure to validate X.509 certificates when used with an on-premise installation with Skype for Business.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2018-10-23 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T11:15:59.735Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2018-027.txt"
              },
              {
                "name": "20181023 [SYSS-2018-027] missing X.509 validation with Polycom VVX Phones (Skype for Business, on-premise) - CVE-2018-18568",
                "tags": [
                  "mailing-list",
                  "x_refsource_BUGTRAQ",
                  "x_transferred"
                ],
                "url": "https://seclists.org/bugtraq/2018/Oct/36"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-10-23T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Polycom VVX 500 and 601 devices 5.8.0.12848 and earlier allows man-in-the-middle attackers to obtain sensitive credential information by leveraging failure to validate X.509 certificates when used with an on-premise installation with Skype for Business."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-10-24T21:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2018-027.txt"
            },
            {
              "name": "20181023 [SYSS-2018-027] missing X.509 validation with Polycom VVX Phones (Skype for Business, on-premise) - CVE-2018-18568",
              "tags": [
                "mailing-list",
                "x_refsource_BUGTRAQ"
              ],
              "url": "https://seclists.org/bugtraq/2018/Oct/36"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-18568",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Polycom VVX 500 and 601 devices 5.8.0.12848 and earlier allows man-in-the-middle attackers to obtain sensitive credential information by leveraging failure to validate X.509 certificates when used with an on-premise installation with Skype for Business."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2018-027.txt",
                  "refsource": "MISC",
                  "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2018-027.txt"
                },
                {
                  "name": "20181023 [SYSS-2018-027] missing X.509 validation with Polycom VVX Phones (Skype for Business, on-premise) - CVE-2018-18568",
                  "refsource": "BUGTRAQ",
                  "url": "https://seclists.org/bugtraq/2018/Oct/36"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-18568",
        "datePublished": "2018-10-24T22:00:00.000Z",
        "dateReserved": "2018-10-22T00:00:00.000Z",
        "dateUpdated": "2024-08-05T11:15:59.735Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2017-12857 (GCVE-0-2017-12857)

    Vulnerability from nvd – Published: 2017-08-25 19:00 – Updated: 2024-08-05 18:51
    VLAI
    Summary
    Polycom SoundStation IP, VVX, and RealPresence Trio that are running software older than UCS 4.0.12, 5.4.5 rev AG, 5.4.7, 5.5.2, or 5.6.0 are affected by a vulnerability in their UCS web application. This vulnerability could allow an authenticated remote attacker to read a segment of the phone's memory which could contain an administrator's password or other sensitive information.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    URL Tags
    http://www.securitytracker.com/id/1039309 vdb-entryx_refsource_SECTRACK
    http://support.polycom.com/content/dam/polycom-su… x_refsource_CONFIRM
    Date Public
    2017-08-25 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T18:51:06.775Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "1039309",
                "tags": [
                  "vdb-entry",
                  "x_refsource_SECTRACK",
                  "x_transferred"
                ],
                "url": "http://www.securitytracker.com/id/1039309"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://support.polycom.com/content/dam/polycom-support/global/documentation/security-advisory-information-disclosure-on-polycom-voice-products-v1.0.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2017-08-25T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Polycom SoundStation IP, VVX, and RealPresence Trio that are running software older than UCS 4.0.12, 5.4.5 rev AG, 5.4.7, 5.5.2, or 5.6.0 are affected by a vulnerability in their UCS web application. This vulnerability could allow an authenticated remote attacker to read a segment of the phone\u0027s memory which could contain an administrator\u0027s password or other sensitive information."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-09-12T09:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "name": "1039309",
              "tags": [
                "vdb-entry",
                "x_refsource_SECTRACK"
              ],
              "url": "http://www.securitytracker.com/id/1039309"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://support.polycom.com/content/dam/polycom-support/global/documentation/security-advisory-information-disclosure-on-polycom-voice-products-v1.0.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2017-12857",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Polycom SoundStation IP, VVX, and RealPresence Trio that are running software older than UCS 4.0.12, 5.4.5 rev AG, 5.4.7, 5.5.2, or 5.6.0 are affected by a vulnerability in their UCS web application. This vulnerability could allow an authenticated remote attacker to read a segment of the phone\u0027s memory which could contain an administrator\u0027s password or other sensitive information."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "1039309",
                  "refsource": "SECTRACK",
                  "url": "http://www.securitytracker.com/id/1039309"
                },
                {
                  "name": "http://support.polycom.com/content/dam/polycom-support/global/documentation/security-advisory-information-disclosure-on-polycom-voice-products-v1.0.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://support.polycom.com/content/dam/polycom-support/global/documentation/security-advisory-information-disclosure-on-polycom-voice-products-v1.0.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2017-12857",
        "datePublished": "2017-08-25T19:00:00.000Z",
        "dateReserved": "2017-08-15T00:00:00.000Z",
        "dateUpdated": "2024-08-05T18:51:06.775Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }