Vulnerabilites related to Siemens - syngo.plaza VB30E
cve-2024-52335
Vulnerability from cvelistv5
Published
2024-12-06 13:14
Modified
2024-12-06 17:58
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C
9.3 (Critical) - CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
9.3 (Critical) - CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
EPSS score ?
Summary
A vulnerability has been identified in syngo.plaza VB30E (All versions < VB30E_HF05). The affected application do not properly sanitize input data before sending it to the SQL server. This could allow an attacker with access to the application could use this vulnerability to execute malicious SQL commands to compromise the whole database.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Siemens | syngo.plaza VB30E |
Version: 0 < VB30E_HF05 |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:siemens:syngo_plaza_vb30e:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "syngo_plaza_vb30e", "vendor": "siemens", "versions": [ { "lessThan": "VB30E_HF05", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-52335", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-12-06T17:55:36.160911Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-12-06T17:58:49.178Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "syngo.plaza VB30E", "vendor": "Siemens", "versions": [ { "lessThan": "VB30E_HF05", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in syngo.plaza VB30E (All versions \u003c VB30E_HF05). The affected application do not properly sanitize input data before sending it to the SQL server. This could allow an attacker with access to the application could use this vulnerability to execute malicious SQL commands to compromise the whole database." } ], "metrics": [ { "cvssV3_1": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 9.3, "baseSeverity": "CRITICAL", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-89", "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-12-06T13:14:16.935Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-160244" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-52335", "datePublished": "2024-12-06T13:14:16.935Z", "dateReserved": "2024-11-08T12:49:09.651Z", "dateUpdated": "2024-12-06T17:58:49.178Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }