Vulnerabilites related to siemens - siprotec_5_7sj81
cve-2022-45044
Vulnerability from cvelistv5
Published
2022-12-13 00:00
Modified
2024-08-03 14:01
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.50), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions < V9.50), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions < V9.50), SIPROTEC 5 6MD89 (CP300) (All versions < V9.64), SIPROTEC 5 6MU85 (CP300) (All versions < V9.50), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions < V9.64), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions < V9.50), SIPROTEC 5 7SA84 (CP200) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions < V9.50), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions < V9.50), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions < V9.50), SIPROTEC 5 7SD84 (CP200) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions < V9.50), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions < V9.50), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.50), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.50), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions < V9.50), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions < V9.50), SIPROTEC 5 7SK82 (CP100) (All versions < V8.89), SIPROTEC 5 7SK82 (CP150) (All versions < V9.50), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions < V9.50), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions < V9.50), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions < V9.50), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions < V9.50), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions < V9.50), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions < V9.64), SIPROTEC 5 7ST86 (CP300) (All versions < V9.64), SIPROTEC 5 7SX82 (CP150) (All versions < V9.50), SIPROTEC 5 7SX85 (CP300) (All versions < V9.50), SIPROTEC 5 7UM85 (CP300) (All versions < V9.50), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions < V9.50), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions < V9.50), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions < V9.50), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions < V9.50), SIPROTEC 5 7VE85 (CP300) (All versions < V9.50), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions < V9.50), SIPROTEC 5 7VU85 (CP300) (All versions < V9.50), SIPROTEC 5 Communication Module ETH-BA-2EL (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (All versions < V9.50 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (All versions < V9.50 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions < V9.50), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.50). Affected devices do not properly restrict secure client-initiated renegotiations within the SSL and TLS protocols. This could allow an attacker to create a denial of service condition on the ports 443/tcp and 4443/tcp for the duration of the attack.
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T14:01:31.505Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-552874.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-552874.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIPROTEC 5 6MD84 (CP300)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.50" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 6MD85 (CP200)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 6MD85 (CP300)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.50" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 6MD86 (CP200)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 6MD86 (CP300)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.50" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 6MD89 (CP300)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.64" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 6MU85 (CP300)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.50" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7KE85 (CP200)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7KE85 (CP300)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.64" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SA82 (CP100)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SA82 (CP150)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.50" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SA84 (CP200)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SA86 (CP200)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SA86 (CP300)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.50" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SA87 (CP200)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SA87 (CP300)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.50" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SD82 (CP100)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SD82 (CP150)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.50" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SD84 (CP200)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SD86 (CP200)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SD86 (CP300)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.50" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SD87 (CP200)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SD87 (CP300)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.50" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SJ81 (CP100)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.89" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SJ81 (CP150)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.50" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SJ82 (CP100)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.89" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SJ82 (CP150)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.50" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SJ85 (CP200)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SJ85 (CP300)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.50" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SJ86 (CP200)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SJ86 (CP300)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.50" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SK82 (CP100)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.89" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SK82 (CP150)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.50" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SK85 (CP200)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SK85 (CP300)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.50" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SL82 (CP100)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SL82 (CP150)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.50" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SL86 (CP200)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SL86 (CP300)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.50" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SL87 (CP200)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SL87 (CP300)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.50" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SS85 (CP200)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SS85 (CP300)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.50" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7ST85 (CP200)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7ST85 (CP300)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.64" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7ST86 (CP300)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.64" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SX82 (CP150)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.50" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SX85 (CP300)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.50" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7UM85 (CP300)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.50" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7UT82 (CP100)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7UT82 (CP150)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.50" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7UT85 (CP200)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7UT85 (CP300)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.50" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7UT86 (CP200)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7UT86 (CP300)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.50" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7UT87 (CP200)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7UT87 (CP300)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.50" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7VE85 (CP300)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.50" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7VK87 (CP200)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7VK87 (CP300)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.50" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7VU85 (CP300)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.50" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 Communication Module ETH-BA-2EL", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.89 installed on CP100 devices" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 Communication Module ETH-BA-2EL", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.50 installed on CP150 and CP300 devices" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 Communication Module ETH-BA-2EL", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions installed on CP200 devices" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 Communication Module ETH-BB-2FO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.89 installed on CP100 devices" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 Communication Module ETH-BB-2FO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.50 installed on CP150 and CP300 devices" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 Communication Module ETH-BB-2FO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions installed on CP200 devices" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 Communication Module ETH-BD-2FO", "vendor": "Siemens", "versions": [ { "lessThan": "V9.50", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 Compact 7SX800 (CP050)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.50" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions \u003c V9.50), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions \u003c V9.50), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions \u003c V9.50), SIPROTEC 5 6MD89 (CP300) (All versions \u003c V9.64), SIPROTEC 5 6MU85 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions \u003c V9.64), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions \u003c V9.50), SIPROTEC 5 7SA84 (CP200) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions \u003c V9.50), SIPROTEC 5 7SD84 (CP200) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7SJ81 (CP100) (All versions \u003c V8.89), SIPROTEC 5 7SJ81 (CP150) (All versions \u003c V9.50), SIPROTEC 5 7SJ82 (CP100) (All versions \u003c V8.89), SIPROTEC 5 7SJ82 (CP150) (All versions \u003c V9.50), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7SK82 (CP100) (All versions \u003c V8.89), SIPROTEC 5 7SK82 (CP150) (All versions \u003c V9.50), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions \u003c V9.50), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions \u003c V9.64), SIPROTEC 5 7ST86 (CP300) (All versions \u003c V9.64), SIPROTEC 5 7SX82 (CP150) (All versions \u003c V9.50), SIPROTEC 5 7SX85 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7UM85 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions \u003c V9.50), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7VE85 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7VU85 (CP300) (All versions \u003c V9.50), SIPROTEC 5 Communication Module ETH-BA-2EL (All versions \u003c V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (All versions \u003c V9.50 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (All versions \u003c V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (All versions \u003c V9.50 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions \u003c V9.50), SIPROTEC 5 Compact 7SX800 (CP050) (All versions \u003c V9.50). Affected devices do not properly restrict secure client-initiated renegotiations within the SSL and TLS protocols. This could allow an attacker to create a denial of service condition on the ports 443/tcp and 4443/tcp for the duration of the attack." } ], "metrics": [ { "cvssV3_1": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:T/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-05-15T07:23:32.902Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-552874.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-552874.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-45044", "datePublished": "2022-12-13T00:00:00", "dateReserved": "2022-11-07T00:00:00", "dateUpdated": "2024-08-03T14:01:31.505Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-28766
Vulnerability from cvelistv5
Published
2023-04-11 09:03
Modified
2024-08-02 13:51
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V9.64), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions < V9.40), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions < V9.40), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.40), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.40), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SK82 (CP100) (All versions < V8.89), SIPROTEC 5 7SK82 (CP150) (All versions < V9.40), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions < V9.40), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7ST85 (CP300) (All versions >= V7.80 < V9.64), SIPROTEC 5 7ST86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SX82 (CP150) (All versions < V9.40), SIPROTEC 5 7SX85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions < V9.40), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7VU85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 Communication Module ETH-BA-2EL (All versions < V9.40 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (All versions < V9.40 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions < V9.40), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.40). Affected devices lack proper validation of http request parameters of the hosted web service.
An unauthenticated remote attacker could send specially crafted packets that could cause denial of service condition of the target device.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIPROTEC 5 6MD85 (CP300) |
Version: V7.80 < V9.40 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T13:51:38.336Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-322980.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-322980.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIPROTEC 5 6MD85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.40", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 6MD86 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.40", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 6MD89 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.64", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 6MU85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.40", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7KE85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.40", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SA82 (CP100)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SA82 (CP150)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.40", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SA86 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.40", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SA87 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.40", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SD82 (CP100)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SD82 (CP150)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.40", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SD86 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.40", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SD87 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.40", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SJ81 (CP100)", "vendor": "Siemens", "versions": [ { "lessThan": "V8.89", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SJ81 (CP150)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.40", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SJ82 (CP100)", "vendor": "Siemens", "versions": [ { "lessThan": "V8.89", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SJ82 (CP150)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.40", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SJ85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.40", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SJ86 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.40", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SK82 (CP100)", "vendor": "Siemens", "versions": [ { "lessThan": "V8.89", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SK82 (CP150)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.40", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SK85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.40", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SL82 (CP100)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SL82 (CP150)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.40", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SL86 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.40", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SL87 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.40", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SS85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.40", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7ST85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.64", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7ST86 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.40", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SX82 (CP150)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.40", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SX85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.40", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7UM85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.40", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7UT82 (CP100)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7UT82 (CP150)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.40", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7UT85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.40", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7UT86 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.40", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7UT87 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.40", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7VE85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.40", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7VK87 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.40", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7VU85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.40", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 Communication Module ETH-BA-2EL", "vendor": "Siemens", "versions": [ { "lessThan": "V9.40", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 Communication Module ETH-BA-2EL", "vendor": "Siemens", "versions": [ { "lessThan": "V8.89", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 Communication Module ETH-BB-2FO", "vendor": "Siemens", "versions": [ { "lessThan": "V9.40", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 Communication Module ETH-BB-2FO", "vendor": "Siemens", "versions": [ { "lessThan": "V8.89", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 Communication Module ETH-BD-2FO", "vendor": "Siemens", "versions": [ { "lessThan": "V9.40", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 Compact 7SX800 (CP050)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.40", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIPROTEC 5 6MD85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 6MD86 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 6MD89 (CP300) (All versions \u003e= V7.80 \u003c V9.64), SIPROTEC 5 6MU85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7KE85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions \u003c V9.40), SIPROTEC 5 7SA86 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SA87 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions \u003c V9.40), SIPROTEC 5 7SD86 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SD87 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SJ81 (CP100) (All versions \u003c V8.89), SIPROTEC 5 7SJ81 (CP150) (All versions \u003c V9.40), SIPROTEC 5 7SJ82 (CP100) (All versions \u003c V8.89), SIPROTEC 5 7SJ82 (CP150) (All versions \u003c V9.40), SIPROTEC 5 7SJ85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SJ86 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SK82 (CP100) (All versions \u003c V8.89), SIPROTEC 5 7SK82 (CP150) (All versions \u003c V9.40), SIPROTEC 5 7SK85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions \u003c V9.40), SIPROTEC 5 7SL86 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SL87 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SS85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7ST85 (CP300) (All versions \u003e= V7.80 \u003c V9.64), SIPROTEC 5 7ST86 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SX82 (CP150) (All versions \u003c V9.40), SIPROTEC 5 7SX85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7UM85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions \u003c V9.40), SIPROTEC 5 7UT85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7UT86 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7UT87 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7VE85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7VK87 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7VU85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 Communication Module ETH-BA-2EL (All versions \u003c V9.40 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (All versions \u003c V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (All versions \u003c V9.40 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (All versions \u003c V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions \u003c V9.40), SIPROTEC 5 Compact 7SX800 (CP050) (All versions \u003c V9.40). Affected devices lack proper validation of http request parameters of the hosted web service.\r\nAn unauthenticated remote attacker could send specially crafted packets that could cause denial of service condition of the target device." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-476", "description": "CWE-476: NULL Pointer Dereference", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-05-15T07:23:35.884Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-322980.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-322980.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-28766", "datePublished": "2023-04-11T09:03:05.547Z", "dateReserved": "2023-03-23T09:09:31.711Z", "dateUpdated": "2024-08-02T13:51:38.336Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2022-12-13 16:15
Modified
2024-11-21 07:28
Severity ?
5.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.50), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions < V9.50), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions < V9.50), SIPROTEC 5 6MD89 (CP300) (All versions < V9.64), SIPROTEC 5 6MU85 (CP300) (All versions < V9.50), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions < V9.64), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions < V9.50), SIPROTEC 5 7SA84 (CP200) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions < V9.50), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions < V9.50), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions < V9.50), SIPROTEC 5 7SD84 (CP200) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions < V9.50), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions < V9.50), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.50), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.50), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions < V9.50), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions < V9.50), SIPROTEC 5 7SK82 (CP100) (All versions < V8.89), SIPROTEC 5 7SK82 (CP150) (All versions < V9.50), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions < V9.50), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions < V9.50), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions < V9.50), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions < V9.50), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions < V9.50), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions < V9.64), SIPROTEC 5 7ST86 (CP300) (All versions < V9.64), SIPROTEC 5 7SX82 (CP150) (All versions < V9.50), SIPROTEC 5 7SX85 (CP300) (All versions < V9.50), SIPROTEC 5 7UM85 (CP300) (All versions < V9.50), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions < V9.50), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions < V9.50), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions < V9.50), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions < V9.50), SIPROTEC 5 7VE85 (CP300) (All versions < V9.50), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions < V9.50), SIPROTEC 5 7VU85 (CP300) (All versions < V9.50), SIPROTEC 5 Communication Module ETH-BA-2EL (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (All versions < V9.50 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (All versions < V9.50 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions < V9.50), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.50). Affected devices do not properly restrict secure client-initiated renegotiations within the SSL and TLS protocols. This could allow an attacker to create a denial of service condition on the ports 443/tcp and 4443/tcp for the duration of the attack.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-552874.html | ||
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-552874.pdf | Mitigation, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/html/ssa-552874.html | ||
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-552874.pdf | Mitigation, Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | siprotec_5_6md85_firmware | - | |
siemens | siprotec_5_6md85 | cp200 | |
siemens | siprotec_5_6md85_firmware | - | |
siemens | siprotec_5_6md85 | cp300 | |
siemens | siprotec_5_6md86_firmware | - | |
siemens | siprotec_5_6md86 | cp200 | |
siemens | siprotec_5_6md86_firmware | - | |
siemens | siprotec_5_6md86 | cp300 | |
siemens | siprotec_5_6md89_firmware | - | |
siemens | siprotec_5_6md89 | cp300 | |
siemens | siprotec_5_6mu85_firmware | - | |
siemens | siprotec_5_6mu85 | cp200 | |
siemens | siprotec_5_6mu85_firmware | - | |
siemens | siprotec_5_6mu85 | cp300 | |
siemens | siprotec_5_7ke85_firmware | - | |
siemens | siprotec_5_7ke85 | cp200 | |
siemens | siprotec_5_7ke85_firmware | - | |
siemens | siprotec_5_7ke85 | cp300 | |
siemens | siprotec_5_7sa82_firmware | - | |
siemens | siprotec_5_7sa82 | cp100 | |
siemens | siprotec_5_7sa82_firmware | - | |
siemens | siprotec_5_7sa82 | cp150 | |
siemens | siprotec_5_7sa86_firmware | - | |
siemens | siprotec_5_7sa86 | cp200 | |
siemens | siprotec_5_7sa86_firmware | - | |
siemens | siprotec_5_7sa86 | cp300 | |
siemens | siprotec_5_7sa87_firmware | - | |
siemens | siprotec_5_7sa87 | cp200 | |
siemens | siprotec_5_7sa87_firmware | - | |
siemens | siprotec_5_7sa87 | cp300 | |
siemens | siprotec_5_7sd82_firmware | - | |
siemens | siprotec_5_7sd82 | cp100 | |
siemens | siprotec_5_7sd82_firmware | - | |
siemens | siprotec_5_7sd82 | cp150 | |
siemens | siprotec_5_7sd86_firmware | - | |
siemens | siprotec_5_7sd86 | cp200 | |
siemens | siprotec_5_7sd86_firmware | - | |
siemens | siprotec_5_7sd86 | cp300 | |
siemens | siprotec_5_7sd87_firmware | - | |
siemens | siprotec_5_7sd87 | cp200 | |
siemens | siprotec_5_7sd87_firmware | - | |
siemens | siprotec_5_7sd87 | cp300 | |
siemens | siprotec_5_7sj81_firmware | - | |
siemens | siprotec_5_7sj81 | cp100 | |
siemens | siprotec_5_7sj81_firmware | - | |
siemens | siprotec_5_7sj81 | cp150 | |
siemens | siprotec_5_7sj82_firmware | - | |
siemens | siprotec_5_7sj82 | cp100 | |
siemens | siprotec_5_7sj82_firmware | - | |
siemens | siprotec_5_7sj82 | cp150 | |
siemens | siprotec_5_7sj85_firmware | - | |
siemens | siprotec_5_7sj85 | cp200 | |
siemens | siprotec_5_7sj85_firmware | - | |
siemens | siprotec_5_7sj85 | cp300 | |
siemens | siprotec_5_7sj86_firmware | - | |
siemens | siprotec_5_7sj86 | cp200 | |
siemens | siprotec_5_7sj86_firmware | - | |
siemens | siprotec_5_7sj86 | cp300 | |
siemens | siprotec_5_7sk82_firmware | - | |
siemens | siprotec_5_7sk82 | cp100 | |
siemens | siprotec_5_7sk82_firmware | - | |
siemens | siprotec_5_7sk82 | cp150 | |
siemens | siprotec_5_7sk85_firmware | - | |
siemens | siprotec_5_7sk85 | cp200 | |
siemens | siprotec_5_7sk85_firmware | - | |
siemens | siprotec_5_7sk85 | cp300 | |
siemens | siprotec_5_7sl82_firmware | - | |
siemens | siprotec_5_7sl82 | cp100 | |
siemens | siprotec_5_7sl82_firmware | - | |
siemens | siprotec_5_7sl82 | cp150 | |
siemens | siprotec_5_7sl86_firmware | - | |
siemens | siprotec_5_7sl86 | cp200 | |
siemens | siprotec_5_7sl86_firmware | - | |
siemens | siprotec_5_7sl86 | cp300 | |
siemens | siprotec_5_7sl87_firmware | - | |
siemens | siprotec_5_7sl87 | cp200 | |
siemens | siprotec_5_7sl87_firmware | - | |
siemens | siprotec_5_7sl87 | cp300 | |
siemens | siprotec_5_7ss85_firmware | - | |
siemens | siprotec_5_7ss85 | cp200 | |
siemens | siprotec_5_7ss85_firmware | - | |
siemens | siprotec_5_7ss85 | cp300 | |
siemens | siprotec_5_7st85_firmware | - | |
siemens | siprotec_5_7st85 | cp200 | |
siemens | siprotec_5_7st85_firmware | - | |
siemens | siprotec_5_7st85 | cp300 | |
siemens | siprotec_5_7sx85_firmware | - | |
siemens | siprotec_5_7sx85 | cp300 | |
siemens | siprotec_5_7um85_firmware | - | |
siemens | siprotec_5_7um85 | cp300 | |
siemens | siprotec_5_7ut82_firmware | - | |
siemens | siprotec_5_7ut82 | cp100 | |
siemens | siprotec_5_7ut82_firmware | - | |
siemens | siprotec_5_7ut82 | cp150 | |
siemens | siprotec_5_7ut85_firmware | - | |
siemens | siprotec_5_7ut85 | cp200 | |
siemens | siprotec_5_7ut85_firmware | - | |
siemens | siprotec_5_7ut85 | cp300 | |
siemens | siprotec_5_7ut86_firmware | - | |
siemens | siprotec_5_7ut86 | cp200 | |
siemens | siprotec_5_7ut86_firmware | - | |
siemens | siprotec_5_7ut86 | cp300 | |
siemens | siprotec_5_7ut87_firmware | - | |
siemens | siprotec_5_7ut87 | cp200 | |
siemens | siprotec_5_7ut87_firmware | - | |
siemens | siprotec_5_7ut87 | cp300 | |
siemens | siprotec_5_7ve85_firmware | - | |
siemens | siprotec_5_7ve85 | cp300 | |
siemens | siprotec_5_7vk87_firmware | - | |
siemens | siprotec_5_7vk87 | cp200 | |
siemens | siprotec_5_7vk87_firmware | - | |
siemens | siprotec_5_7vk87 | cp300 | |
siemens | siprotec_5_communication_module_ethba2el_firmware | - | |
siemens | siprotec_5_communication_module_ethba2el | - | |
siemens | siprotec_5_communication_module_ethbb2fo_firmware | - | |
siemens | siprotec_5_communication_module_ethbb2fo | - | |
siemens | siprotec_5_communication_module_ethbd2fo_firmware | - | |
siemens | siprotec_5_communication_module_ethbd2fo | - | |
siemens | siprotec_5_compact_7sx800_firmware | - | |
siemens | siprotec_5_compact_7sx800 | cp050 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_6md85_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "E22A051D-40EC-425D-911F-5C2A97349CB4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_6md85:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "D4CC1B1C-9EB5-4235-BC3C-D20F39567A69", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_6md85_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "E22A051D-40EC-425D-911F-5C2A97349CB4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_6md85:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "6A111316-A19F-47CD-87CB-860C90205A90", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_6md86_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "A1633FC5-AA65-4E16-B92F-FA385B252CBA", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_6md86:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "640BF11A-A17B-4F8B-9D2B-1C1D2D4075BA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_6md86_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "A1633FC5-AA65-4E16-B92F-FA385B252CBA", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_6md86:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "31902FCD-60CD-48BF-9783-423D99AFA813", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_6md89_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "C6AB71CC-7DEA-439D-B719-14CA355C3A87", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_6md89:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "C7084F2B-5865-4ED1-9A6A-E369FC0F1BEB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_6mu85_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "6C68B9E7-76C2-4F35-AC5E-BA1A939D3D25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_6mu85:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "648898BC-147E-462F-8807-1CD9BF3113D9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_6mu85_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "6C68B9E7-76C2-4F35-AC5E-BA1A939D3D25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_6mu85:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "1452A607-3CD5-4928-AB0B-169B262703E1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7ke85_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "15EDD8FD-3DE0-426B-BA12-429415BB14F8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7ke85:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "FC91C797-4849-4A3B-8100-E2AFE3B4272E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7ke85_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "15EDD8FD-3DE0-426B-BA12-429415BB14F8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7ke85:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "B9C327E6-E0C8-430C-A314-E3D1A60A6809", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sa82_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "9553DE28-D9EB-4072-AF16-936EAD0CB6AC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sa82:cp100:*:*:*:*:*:*:*", "matchCriteriaId": "5BC0B29E-2407-4473-81AB-647648E2B05A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sa82_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "9553DE28-D9EB-4072-AF16-936EAD0CB6AC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sa82:cp150:*:*:*:*:*:*:*", "matchCriteriaId": "6F61F485-9A80-45A3-BD5A-6526916EC0EA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sa86_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "9A3043DF-964C-43F6-AB07-649832080479", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sa86:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "08B16445-C707-4D26-8C8A-F1166F85A64B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sa86_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "9A3043DF-964C-43F6-AB07-649832080479", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sa86:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "8A1DCC8A-5795-4253-A111-5C0EF29FB4B7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sa87_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "368158B8-A626-4ABC-874E-E6A2DF81FD81", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sa87:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "8FE5CD98-00BD-4AEA-8E3F-2A8AE215AAFA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sa87_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "368158B8-A626-4ABC-874E-E6A2DF81FD81", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sa87:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "FDD47A1D-993D-449D-9E23-8D0A5D9B14E1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sd82_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "A452FF73-3824-4948-97A1-399DB5AADC9C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sd82:cp100:*:*:*:*:*:*:*", "matchCriteriaId": "8D3E5539-B71B-453E-8397-C2A714646D51", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sd82_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "A452FF73-3824-4948-97A1-399DB5AADC9C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sd82:cp150:*:*:*:*:*:*:*", "matchCriteriaId": "A9CD8B78-EC91-4507-A0F8-3159935DFE42", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sd86_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "737CDED1-CA67-453B-9B2A-43FCAEB29756", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sd86:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "C88252DD-84A0-4245-BF75-5A59061FC45F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sd86_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "737CDED1-CA67-453B-9B2A-43FCAEB29756", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sd86:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "D9C43FC0-76C8-4E52-9AFE-5498F54BF1D5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sd87_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "1B39DA20-3FB1-453D-800B-7AC88203D59B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sd87:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "3296A090-50EE-4203-8D19-8610D0784037", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sd87_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "1B39DA20-3FB1-453D-800B-7AC88203D59B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sd87:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "0E8F3C87-242C-4606-B139-5E64BBAB18D5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sj81_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "E1FD1EBF-6C21-48E9-9572-DEF1F5EDF0B6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sj81:cp100:*:*:*:*:*:*:*", "matchCriteriaId": "6E8FD72B-E34D-4F7E-ADDF-00955A58299F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sj81_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "E1FD1EBF-6C21-48E9-9572-DEF1F5EDF0B6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sj81:cp150:*:*:*:*:*:*:*", "matchCriteriaId": "A9EB411D-D0AA-4CDD-BDBB-C3D90F9C53ED", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sj82_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "B4498D5D-84B9-4EF1-ADFA-8EE89A8248EA", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sj82:cp100:*:*:*:*:*:*:*", "matchCriteriaId": "83094A08-9EFC-4CB8-BFF6-20C17F3E1682", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sj82_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "B4498D5D-84B9-4EF1-ADFA-8EE89A8248EA", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sj82:cp150:*:*:*:*:*:*:*", "matchCriteriaId": "DC03BAAF-4507-483F-BF1A-67D8944638A9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sj85_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "A0690077-33B2-4356-9ACB-889F0D1C0A1D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sj85:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "0AFB2251-7B60-49B6-A9C6-98F47FADE02D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sj85_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "A0690077-33B2-4356-9ACB-889F0D1C0A1D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sj85:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "466A7D08-762C-4F17-BC44-A81876D24074", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sj86_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E36DA40-23A6-4202-A1DC-3F0DD896EC66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sj86:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "9D2D8944-6F54-4528-A2EE-56F54454F941", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sj86_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E36DA40-23A6-4202-A1DC-3F0DD896EC66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sj86:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "B5E80208-787F-49BD-88C9-A5F51D7FA367", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sk82_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "455CAAA3-E0DF-4CD1-972D-D3A2545797D1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sk82:cp100:*:*:*:*:*:*:*", "matchCriteriaId": "08ABC5D4-F8CF-47D7-B482-8E6771DD3213", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sk82_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "455CAAA3-E0DF-4CD1-972D-D3A2545797D1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sk82:cp150:*:*:*:*:*:*:*", "matchCriteriaId": "E0A9451D-AC58-4CC5-BE77-18DF5C7A4A47", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sk85_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "A627EAD7-470D-485B-B5C4-07617B074F22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sk85:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "CF56A2EE-6D67-4C60-88A1-7ADB77B89088", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sk85_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "A627EAD7-470D-485B-B5C4-07617B074F22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sk85:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "0D919812-54DF-4861-B809-861197F597CF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sl82_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "5447A73E-F153-464B-935B-B052FCE014AA", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sl82:cp100:*:*:*:*:*:*:*", "matchCriteriaId": "4F0D9D58-C0A1-4634-887A-0A62117AAC2C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sl82_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "5447A73E-F153-464B-935B-B052FCE014AA", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sl82:cp150:*:*:*:*:*:*:*", "matchCriteriaId": "289B2058-EF26-4965-A713-344E278CC5D4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sl86_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "EE508B38-836F-4FF1-94D3-2209F1900B88", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sl86:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "7B437991-E019-41BD-AAA0-BE663CC0BD53", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sl86_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "EE508B38-836F-4FF1-94D3-2209F1900B88", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sl86:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "49C49601-7A9B-47AC-AFC0-D37674E520A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sl87_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "0BF49E0A-F508-430C-9770-B7DAA55ECCF9", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sl87:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "F979441B-57A5-427B-B67C-04267322F2F5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sl87_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "0BF49E0A-F508-430C-9770-B7DAA55ECCF9", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sl87:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "FB997A05-826D-4E4D-9FE9-05EBAFD7C9F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7ss85_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "734A86D1-831A-463A-87A1-D0FE12BA34E3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7ss85:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "E229DA19-6D09-4D5C-9FBD-15009F36CFBC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7ss85_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "734A86D1-831A-463A-87A1-D0FE12BA34E3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7ss85:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "2354C161-5D95-43DD-8735-70EAFFB96A35", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7st85_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "C2AAE0F7-3B4B-4A57-8DD1-7512E78C3AF0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7st85:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "BE32C2B7-4EA5-44E3-A8A8-122AE1C937C5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7st85_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "C2AAE0F7-3B4B-4A57-8DD1-7512E78C3AF0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7st85:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "3DDE4AA1-E4A6-4A86-9826-BBFC7A076F95", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sx85_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "1A6AE60D-3FA4-4700-8DD7-2AD8105A298E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sx85:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "1A07BC72-9EA0-4D12-A9F8-8E3E8E522F94", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7um85_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "480158A1-C487-42D9-9C9F-496978DA6B96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7um85:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "176D2DA2-3429-4CE3-A7CB-F1EBA54ADC24", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7ut82_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "D1FB0725-E7F6-45CF-9B3A-9E26589EBA2F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7ut82:cp100:*:*:*:*:*:*:*", "matchCriteriaId": "01B099AA-77B5-4A8A-BB1E-E30C754A047A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7ut82_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "D1FB0725-E7F6-45CF-9B3A-9E26589EBA2F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7ut82:cp150:*:*:*:*:*:*:*", "matchCriteriaId": "E83EC770-F876-4518-A625-742268FAC1C7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7ut85_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "D7F73308-D570-48D4-9B67-F94E37105363", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7ut85:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "563D1E66-BECC-4A8A-A002-3CCCBB7F4DE2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7ut85_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "D7F73308-D570-48D4-9B67-F94E37105363", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7ut85:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "CD4C3BC9-0D67-46D0-9033-F5D9BB4E27A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7ut86_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "17A1E87B-D702-48C5-B29C-D7A0996EF7B6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7ut86:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "99CEF9BE-987E-40A5-A1CA-55A5F52899F5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7ut86_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "17A1E87B-D702-48C5-B29C-D7A0996EF7B6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7ut86:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "120ADDE5-167C-482F-8DD4-FD90B0C79027", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7ut87_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "79D3EA52-D551-402A-977D-8409035857CF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7ut87:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "E830FAFE-60D8-4758-843B-31058C682656", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7ut87_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "79D3EA52-D551-402A-977D-8409035857CF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7ut87:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "ADEE1942-0B7F-439C-829B-B92F300EC76B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7ve85_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "B1AE8A73-578A-4076-B6CC-3E2E5E0CFED1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7ve85:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "8A39EFCE-2926-4E58-8521-18DC7A5246B3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7vk87_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "9B0B967E-2021-4000-A327-995D39B75BC8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7vk87:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "16390127-25E5-4188-9977-9A1F1A085F33", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7vk87_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "9B0B967E-2021-4000-A327-995D39B75BC8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7vk87:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "435A96CD-B713-46D0-882D-5F78DD8769A2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_communication_module_ethba2el_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "EEB1BB43-7C10-4078-A13F-218A67654E85", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_communication_module_ethba2el:-:*:*:*:*:*:*:*", "matchCriteriaId": "1AF3C9BB-2A5E-4C19-BB2B-85466A339559", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_communication_module_ethbb2fo_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "22D9DD07-4B59-4B0E-AAA8-34F9C52D59FF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_communication_module_ethbb2fo:-:*:*:*:*:*:*:*", "matchCriteriaId": "21DCC99B-0D05-4434-9234-099FE3125971", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_communication_module_ethbd2fo_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "CB602D88-4E13-4B19-82BB-58723D97C028", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_communication_module_ethbd2fo:-:*:*:*:*:*:*:*", "matchCriteriaId": "ABE48BEE-223F-4E50-B013-36577693B6F5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_compact_7sx800_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "43634EA6-9F64-4423-854C-B66546615422", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_compact_7sx800:cp050:*:*:*:*:*:*:*", "matchCriteriaId": "839E7AF3-C681-4882-8F06-8FC1E7B520C2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions \u003c V9.50), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions \u003c V9.50), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions \u003c V9.50), SIPROTEC 5 6MD89 (CP300) (All versions \u003c V9.64), SIPROTEC 5 6MU85 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions \u003c V9.64), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions \u003c V9.50), SIPROTEC 5 7SA84 (CP200) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions \u003c V9.50), SIPROTEC 5 7SD84 (CP200) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7SJ81 (CP100) (All versions \u003c V8.89), SIPROTEC 5 7SJ81 (CP150) (All versions \u003c V9.50), SIPROTEC 5 7SJ82 (CP100) (All versions \u003c V8.89), SIPROTEC 5 7SJ82 (CP150) (All versions \u003c V9.50), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7SK82 (CP100) (All versions \u003c V8.89), SIPROTEC 5 7SK82 (CP150) (All versions \u003c V9.50), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions \u003c V9.50), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions \u003c V9.64), SIPROTEC 5 7ST86 (CP300) (All versions \u003c V9.64), SIPROTEC 5 7SX82 (CP150) (All versions \u003c V9.50), SIPROTEC 5 7SX85 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7UM85 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions \u003c V9.50), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7VE85 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions \u003c V9.50), SIPROTEC 5 7VU85 (CP300) (All versions \u003c V9.50), SIPROTEC 5 Communication Module ETH-BA-2EL (All versions \u003c V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (All versions \u003c V9.50 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (All versions \u003c V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (All versions \u003c V9.50 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions \u003c V9.50), SIPROTEC 5 Compact 7SX800 (CP050) (All versions \u003c V9.50). Affected devices do not properly restrict secure client-initiated renegotiations within the SSL and TLS protocols. This could allow an attacker to create a denial of service condition on the ports 443/tcp and 4443/tcp for the duration of the attack." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en \nSIPROTEC 5 6MD84 (CP300) (versiones \u0026lt; V9.50), SIPROTEC 5 6MD85 (CP200) (Todas las versiones), \nSIPROTEC 5 6MD85 (CP300) (versiones \u0026lt; V9.50), SIPROTEC 5 6MD86 (CP200) (Todas las versiones), \nSIPROTEC 5 6MD86 (CP300) (versiones \u0026lt; V9.50), SIPROTEC 5 6MD89 (CP300) (versiones \u0026lt; V9.60), \nSIPROTEC 5 6MU85 (CP300) (versiones \u0026lt; V9. 50), SIPROTEC 5 7KE85 (CP200) (Todas las versiones), \nSIPROTEC 5 7KE85 (CP300) (versiones \u0026lt; V9.60), SIPROTEC 5 7SA82 (CP100) (Todas las versiones), \nSIPROTEC 5 7SA82 (CP150) (versiones \u0026lt; V9.50), SIPROTEC 5 7SA84 (CP200) (Todas las versiones), \nSIPROTEC 5 7SA86 (CP200) (Todas las versiones), SIPROTEC 5 7SA86 (CP300) (versiones \u0026lt; V9.50), \nSIPROTEC 5 7SA87 (CP200) (Todas las versiones), SIPROTEC 5 7SA87 (CP300) (versiones \u0026lt; V9.50), \nSIPROTEC 5 7SD82 (CP100) (Todas las versiones), SIPROTEC 5 7SD82 (CP150) (versiones \u0026lt; V9.50), \nSIPROTEC 5 7SD84 (CP200) (Todas las versiones), SIPROTEC 5 7SD86 (CP200) (Todas las versiones), \nSIPROTEC 5 7SD86 (CP300) (versiones \u0026lt; V9.50), SIPROTEC 5 7SD87 (CP200) (Todas las versiones), \nSIPROTEC 5 7SD87 (CP300) (versiones \u0026lt; V9.50), SIPROTEC 5 7SJ81 (CP100) (Todas las versiones), \nSIPROTEC 5 7SJ81 (CP150) (versiones \u0026lt; V9.50), SIPROTEC 5 7SJ82 (CP100) (Todas las versiones), \nSIPROTEC 5 7SJ82 (CP150) (versiones \u0026lt; V9.50), SIPROTEC 5 7SJ85 (CP200) (Todas las versiones), \nSIPROTEC 5 7SJ85 (CP300) (versiones \u0026lt; V9.50), SIPROTEC 5 7SJ86 (CP200) (Todas las versiones), \nSIPROTEC 5 7SJ86 ( CP300) (versiones \u0026lt; V9.50), SIPROTEC 5 7SK82 (CP100) (Todas las versiones), \nSIPROTEC 5 7SK82 (CP150) (versiones \u0026lt; V9.50), SIPROTEC 5 7SK85 (CP200) (Todas las versiones),\nSIPROTEC 5 7SK85 (CP300) (versiones \u0026lt; V9.50), SIPROTEC 5 7SL82 (CP100) (Todas las versiones), \nSIPROTEC 5 7SL82 (CP150) (versiones \u0026lt; V9.50), SIPROTEC 5 7SL86 (CP200) (Todas las versiones),\nSIPROTEC 5 7SL86 (CP300) (versiones \u0026lt; V9.50), SIPROTEC 5 7SL87 (CP200) (Todas las versiones), \nSIPROTEC 5 7SL87 (CP300) (versiones \u0026lt; V9.50), SIPROTEC 5 7SS85 (CP200) (Todas las versiones), \nSIPROTEC 5 7SS85 (CP300) (versiones \u0026lt; V9.50), SIPROTEC 5 7ST85 (CP200) (Todas las versiones), \nSIPROTEC 5 7ST85 (CP300) (versiones \u0026lt; V9.60), SIPROTEC 5 7ST86 (CP300) (versiones \u0026lt; V9.60), \nSIPROTEC 5 7SX82 (CP150) (versiones \u0026lt; V9.50), SIPROTEC 5 7SX85 (CP300) (versiones \u0026lt; V9.50), \nSIPROTEC 5 7UM85 (CP300) (versiones \u0026lt; V9. 50), SIPROTEC 5 7UT82 (CP100) (Todas las versiones), \nSIPROTEC 5 7UT82 (CP150) (versiones \u0026lt; V9.50), SIPROTEC 5 7UT85 (CP200) (Todas las versiones), \nSIPROTEC 5 7UT85 (CP300) (versiones \u0026lt; V9.50), SIPROTEC 5 7UT86 (CP200) (Todas las versiones), \nSIPROTEC 5 7UT86 (CP300) (versiones \u0026lt; V9.50), SIPROTEC 5 7UT87 (CP200) (Todas las versiones), \nSIPROTEC 5 7UT87 (CP300) (versiones \u0026lt; V9.50), SIPROTEC 5 7VE85 (CP300) (versiones \u0026lt; V9.50), \nSIPROTEC 5 7VK87 (CP200) (Todas las versiones), SIPROTEC 5 7VK87 (CP300) (versiones \u0026lt; V9.50), \nSIPROTEC 5 7VU85 (CP300) (versiones \u0026lt; V9.50), SIPROTEC 5 Communication Module ETH-BA-2EL (versiones \u0026lt; V9.50 instaladas en dispositivos CP150 y CP300), \nSIPROTEC 5 Communication Module ETH-BA-2EL (Todas las versiones instaladas en dispositivos CP100 y CP200), \nSIPROTEC 5 Communication Module ETH-BB-2FO (versiones \u0026lt; V9.50 instaladas en dispositivos CP150 y CP300), SIPROTEC 5 Communication Module ETH-BB-2FO (Todas las versiones instaladas en dispositivos CP100 y CP200) , \nSIPROTEC 5 Communication Module ETH-BD-2FO (versiones \u0026lt; V9.50), SIPROTEC 5 Compact 7SX800 (CP050) (versiones \u0026lt; V9.50). \n\nLos dispositivos afectados no restringen adecuadamente las renegociaciones seguras iniciadas por el cliente dentro de los protocolos SSL y TLS. Esto podr\u00eda permitir a un atacante crear una condici\u00f3n de denegaci\u00f3n de servicio en los puertos 443/tcp y 4443/tcp mientras dure el ataque." } ], "id": "CVE-2022-45044", "lastModified": "2024-11-21T07:28:39.987", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 1.4, "source": "productcert@siemens.com", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Secondary" } ] }, "published": "2022-12-13T16:15:24.617", "references": [ { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-552874.html" }, { "source": "productcert@siemens.com", "tags": [ "Mitigation", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-552874.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/html/ssa-552874.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mitigation", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-552874.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2023-04-11 10:15
Modified
2024-11-21 07:55
Severity ?
Summary
A vulnerability has been identified in SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V9.64), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions < V9.40), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions < V9.40), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.40), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.40), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SK82 (CP100) (All versions < V8.89), SIPROTEC 5 7SK82 (CP150) (All versions < V9.40), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions < V9.40), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7ST85 (CP300) (All versions >= V7.80 < V9.64), SIPROTEC 5 7ST86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SX82 (CP150) (All versions < V9.40), SIPROTEC 5 7SX85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions < V9.40), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7VU85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 Communication Module ETH-BA-2EL (All versions < V9.40 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (All versions < V9.40 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions < V9.40), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.40). Affected devices lack proper validation of http request parameters of the hosted web service.
An unauthenticated remote attacker could send specially crafted packets that could cause denial of service condition of the target device.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-322980.html | ||
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-322980.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/html/ssa-322980.html | ||
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-322980.pdf | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | siprotec_5_6md85_firmware | * | |
siemens | siprotec_5_6md85 | cp200 | |
siemens | siprotec_5_6md85_firmware | * | |
siemens | siprotec_5_6md85 | cp300 | |
siemens | siprotec_5_6md86_firmware | * | |
siemens | siprotec_5_6md86 | cp200 | |
siemens | siprotec_5_6md86_firmware | * | |
siemens | siprotec_5_6md86 | cp300 | |
siemens | siprotec_5_6md89_firmware | * | |
siemens | siprotec_5_6md89 | cp300 | |
siemens | siprotec_5_6mu85_firmware | * | |
siemens | siprotec_5_6mu85 | cp300 | |
siemens | siprotec_5_7ke85_firmware | * | |
siemens | siprotec_5_7ke85 | cp200 | |
siemens | siprotec_5_7ke85_firmware | * | |
siemens | siprotec_5_7ke85 | cp300 | |
siemens | siprotec_5_7sa82_firmware | * | |
siemens | siprotec_5_7sa82 | cp100 | |
siemens | siprotec_5_7sa82_firmware | * | |
siemens | siprotec_5_7sa82 | cp150 | |
siemens | siprotec_5_7sa86_firmware | * | |
siemens | siprotec_5_7sa86 | cp200 | |
siemens | siprotec_5_7sa86_firmware | * | |
siemens | siprotec_5_7sa86 | cp300 | |
siemens | siprotec_5_7sa87_firmware | * | |
siemens | siprotec_5_7sa87 | cp200 | |
siemens | siprotec_5_7sa87_firmware | * | |
siemens | siprotec_5_7sa87 | cp300 | |
siemens | siprotec_5_7sd82_firmware | * | |
siemens | siprotec_5_7sd82 | cp100 | |
siemens | siprotec_5_7sd82_firmware | * | |
siemens | siprotec_5_7sd82 | cp150 | |
siemens | siprotec_5_7sd86_firmware | * | |
siemens | siprotec_5_7sd86 | cp200 | |
siemens | siprotec_5_7sd86_firmware | * | |
siemens | siprotec_5_7sd86 | cp300 | |
siemens | siprotec_5_7sd87_firmware | * | |
siemens | siprotec_5_7sd87 | cp200 | |
siemens | siprotec_5_7sd87_firmware | * | |
siemens | siprotec_5_7sd87 | cp300 | |
siemens | siprotec_5_7sj81_firmware | * | |
siemens | siprotec_5_7sj81 | cp100 | |
siemens | siprotec_5_7sj81_firmware | * | |
siemens | siprotec_5_7sj81 | cp150 | |
siemens | siprotec_5_7sj82_firmware | * | |
siemens | siprotec_5_7sj82 | cp100 | |
siemens | siprotec_5_7sj82_firmware | * | |
siemens | siprotec_5_7sj82 | cp150 | |
siemens | siprotec_5_7sj85_firmware | * | |
siemens | siprotec_5_7sj85 | cp200 | |
siemens | siprotec_5_7sj85_firmware | * | |
siemens | siprotec_5_7sj85 | cp300 | |
siemens | siprotec_5_7sj86_firmware | * | |
siemens | siprotec_5_7sj86 | cp200 | |
siemens | siprotec_5_7sj86_firmware | * | |
siemens | siprotec_5_7sj86 | cp300 | |
siemens | siprotec_5_7sk82_firmware | * | |
siemens | siprotec_5_7sk82 | cp100 | |
siemens | siprotec_5_7sk82_firmware | * | |
siemens | siprotec_5_7sk82 | cp150 | |
siemens | siprotec_5_7sk85_firmware | * | |
siemens | siprotec_5_7sk85 | cp200 | |
siemens | siprotec_5_7sk85_firmware | * | |
siemens | siprotec_5_7sk85 | cp300 | |
siemens | siprotec_5_7sl82_firmware | * | |
siemens | siprotec_5_7sl82 | cp100 | |
siemens | siprotec_5_7sl82_firmware | * | |
siemens | siprotec_5_7sl82 | cp150 | |
siemens | siprotec_5_7sl86_firmware | * | |
siemens | siprotec_5_7sl86 | cp200 | |
siemens | siprotec_5_7sl86_firmware | * | |
siemens | siprotec_5_7sl86 | cp300 | |
siemens | siprotec_5_7sl87_firmware | * | |
siemens | siprotec_5_7sl87 | cp200 | |
siemens | siprotec_5_7sl87_firmware | * | |
siemens | siprotec_5_7sl87 | cp300 | |
siemens | siprotec_5_7ss85_firmware | * | |
siemens | siprotec_5_7ss85 | cp200 | |
siemens | siprotec_5_7ss85_firmware | * | |
siemens | siprotec_5_7ss85 | cp300 | |
siemens | siprotec_5_7st85_firmware | * | |
siemens | siprotec_5_7st85 | cp200 | |
siemens | siprotec_5_7st85_firmware | * | |
siemens | siprotec_5_7st85 | cp300 | |
siemens | siprotec_5_7sx85_firmware | * | |
siemens | siprotec_5_7sx85 | cp300 | |
siemens | siprotec_5_7um85_firmware | * | |
siemens | siprotec_5_7um85 | cp300 | |
siemens | siprotec_5_7ut82_firmware | * | |
siemens | siprotec_5_7ut82 | cp100 | |
siemens | siprotec_5_7ut82_firmware | * | |
siemens | siprotec_5_7ut82 | cp150 | |
siemens | siprotec_5_7ut85_firmware | * | |
siemens | siprotec_5_7ut85 | cp200 | |
siemens | siprotec_5_7ut85_firmware | * | |
siemens | siprotec_5_7ut85 | cp300 | |
siemens | siprotec_5_7ut86_firmware | * | |
siemens | siprotec_5_7ut86 | cp200 | |
siemens | siprotec_5_7ut86_firmware | * | |
siemens | siprotec_5_7ut86 | cp300 | |
siemens | siprotec_5_7ut87_firmware | * | |
siemens | siprotec_5_7ut87 | cp200 | |
siemens | siprotec_5_7ut87_firmware | * | |
siemens | siprotec_5_7ut87 | cp300 | |
siemens | siprotec_5_7ve85_firmware | * | |
siemens | siprotec_5_7ve85 | cp300 | |
siemens | siprotec_5_7vk87_firmware | * | |
siemens | siprotec_5_7vk87 | cp200 | |
siemens | siprotec_5_7vk87_firmware | * | |
siemens | siprotec_5_7vk87 | cp300 | |
siemens | siprotec_5_communication_module_ethba2el_firmware | * | |
siemens | siprotec_5_communication_module_ethba2el | - | |
siemens | siprotec_5_communication_module_ethbb2fo_firmware | * | |
siemens | siprotec_5_communication_module_ethbb2fo | - | |
siemens | siprotec_5_communication_module_ethbd2fo_firmware | * | |
siemens | siprotec_5_communication_module_ethbd2fo | - | |
siemens | siprotec_5_compact_7sx800_firmware | * | |
siemens | siprotec_5_compact_7sx800 | cp050 | |
siemens | siprotec_5_7sa84_firmware | * | |
siemens | siprotec_5_7sa84 | cp200 | |
siemens | siprotec_5_7sd84_firmware | * | |
siemens | siprotec_5_7sd84 | cp200 | |
siemens | siprotec_5_7st86_firmware | * | |
siemens | siprotec_5_7st86 | cp300 | |
siemens | siprotec_5_7sx82_firmware | * | |
siemens | siprotec_5_7sx82 | cp150 | |
siemens | siprotec_5_7vu85_firmware | * | |
siemens | siprotec_5_7vu85 | cp300 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_6md85_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6A0D29DB-48A2-4A00-8B91-F336CC5E4FBE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_6md85:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "D4CC1B1C-9EB5-4235-BC3C-D20F39567A69", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_6md85_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C1C2A76-380A-4121-8A73-6A0EF336C8D9", "versionEndExcluding": "9.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_6md85:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "6A111316-A19F-47CD-87CB-860C90205A90", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_6md86_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CB4BC292-1845-4F87-85EF-FA227CA6BA0A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_6md86:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "640BF11A-A17B-4F8B-9D2B-1C1D2D4075BA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_6md86_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D248593-B211-419C-B0EA-883AB75AB191", "versionEndExcluding": "9.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_6md86:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "31902FCD-60CD-48BF-9783-423D99AFA813", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_6md89_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "66F75F3B-AA90-463B-AFB0-7D25BDADE3F5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_6md89:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "C7084F2B-5865-4ED1-9A6A-E369FC0F1BEB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_6mu85_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "546B673C-FBCC-4449-A1B7-1F5B25AC0F15", "versionEndExcluding": "9.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_6mu85:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "1452A607-3CD5-4928-AB0B-169B262703E1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7ke85_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EACDE50E-CD2D-482A-B662-7ACF6BC09311", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7ke85:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "FC91C797-4849-4A3B-8100-E2AFE3B4272E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7ke85_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "61C2EDD8-8466-4B0E-BCC3-20FD36C3E114", "versionEndExcluding": "9.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7ke85:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "B9C327E6-E0C8-430C-A314-E3D1A60A6809", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sa82_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1A81C84C-AA56-480C-85FF-8BF0B13BA278", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sa82:cp100:*:*:*:*:*:*:*", "matchCriteriaId": "5BC0B29E-2407-4473-81AB-647648E2B05A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sa82_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BD24BEEE-813D-48A5-AB8A-D91F095493C8", "versionEndExcluding": "9.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sa82:cp150:*:*:*:*:*:*:*", "matchCriteriaId": "6F61F485-9A80-45A3-BD5A-6526916EC0EA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sa86_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "90068748-1128-46DA-A0A1-8712FAB0DC7F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sa86:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "08B16445-C707-4D26-8C8A-F1166F85A64B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sa86_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "952F74A7-D7DA-4253-8850-5449044D42E2", "versionEndExcluding": "9.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sa86:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "8A1DCC8A-5795-4253-A111-5C0EF29FB4B7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sa87_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F9C7421C-2DBE-44A7-83BB-C073F8BAC848", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sa87:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "8FE5CD98-00BD-4AEA-8E3F-2A8AE215AAFA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sa87_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5532456A-2CED-47E0-961F-1734C5AE5049", "versionEndExcluding": "9.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sa87:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "FDD47A1D-993D-449D-9E23-8D0A5D9B14E1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sd82_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F1D59E9-63FA-473C-860E-4ACBD0D0B77F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sd82:cp100:*:*:*:*:*:*:*", "matchCriteriaId": "8D3E5539-B71B-453E-8397-C2A714646D51", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sd82_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "694F4536-1802-49B5-8823-743F174E844D", "versionEndExcluding": "9.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sd82:cp150:*:*:*:*:*:*:*", "matchCriteriaId": "A9CD8B78-EC91-4507-A0F8-3159935DFE42", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sd86_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2077F31A-5938-402F-B8AF-44E26CE9634D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sd86:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "C88252DD-84A0-4245-BF75-5A59061FC45F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sd86_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "46965175-C2E4-492A-9ADC-4653EFB82A66", "versionEndExcluding": "9.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sd86:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "D9C43FC0-76C8-4E52-9AFE-5498F54BF1D5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sd87_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9B9852DB-ED49-415B-AE21-4A974F4FEB74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sd87:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "3296A090-50EE-4203-8D19-8610D0784037", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sd87_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "09B91947-FC3A-4E55-BA46-FC79ECED1EB6", "versionEndExcluding": "9.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sd87:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "0E8F3C87-242C-4606-B139-5E64BBAB18D5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sj81_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4D0B011-FDC2-4C8B-9DB2-BC3A64A3C9AF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sj81:cp100:*:*:*:*:*:*:*", "matchCriteriaId": "6E8FD72B-E34D-4F7E-ADDF-00955A58299F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sj81_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8A1F7FD7-EA88-424B-9B5B-25DE5D62BC3A", "versionEndExcluding": "9.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sj81:cp150:*:*:*:*:*:*:*", "matchCriteriaId": "A9EB411D-D0AA-4CDD-BDBB-C3D90F9C53ED", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sj82_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1C2D1FE4-499C-47C1-B47F-904DE2DC32F0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sj82:cp100:*:*:*:*:*:*:*", "matchCriteriaId": "83094A08-9EFC-4CB8-BFF6-20C17F3E1682", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sj82_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5B8B47A5-EFFE-4F0E-8BBA-9AEF6D629920", "versionEndExcluding": "9.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sj82:cp150:*:*:*:*:*:*:*", "matchCriteriaId": "DC03BAAF-4507-483F-BF1A-67D8944638A9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sj85_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "95686A74-193F-4016-AAF0-E24B60735EFC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sj85:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "0AFB2251-7B60-49B6-A9C6-98F47FADE02D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sj85_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CD3FA333-6DC9-4C9F-81C3-D72AF6DE6DE0", "versionEndExcluding": "9.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sj85:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "466A7D08-762C-4F17-BC44-A81876D24074", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sj86_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D0913FC3-7E96-4B12-B576-C7592873EC56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sj86:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "9D2D8944-6F54-4528-A2EE-56F54454F941", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sj86_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AF51F61C-E0C9-40C0-BB97-AC75DA4894EC", "versionEndExcluding": "9.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sj86:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "B5E80208-787F-49BD-88C9-A5F51D7FA367", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sk82_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E9DD37B3-6C4D-4362-A87B-1DB570B34F71", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sk82:cp100:*:*:*:*:*:*:*", "matchCriteriaId": "08ABC5D4-F8CF-47D7-B482-8E6771DD3213", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sk82_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AA40B67E-C7F0-4DDA-9C33-058FF2770630", "versionEndExcluding": "9.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sk82:cp150:*:*:*:*:*:*:*", "matchCriteriaId": "E0A9451D-AC58-4CC5-BE77-18DF5C7A4A47", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sk85_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4393A068-93FF-4597-88BE-DDA15B3CC374", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sk85:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "CF56A2EE-6D67-4C60-88A1-7ADB77B89088", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sk85_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "52E922D9-98DD-4EB0-9EC4-31A958C29A2C", "versionEndExcluding": "9.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sk85:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "0D919812-54DF-4861-B809-861197F597CF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sl82_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44762C83-76EB-48C8-9A17-4EA22814DB83", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sl82:cp100:*:*:*:*:*:*:*", "matchCriteriaId": "4F0D9D58-C0A1-4634-887A-0A62117AAC2C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sl82_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D673C294-90F4-4132-A0C1-D243105CC29F", "versionEndExcluding": "9.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sl82:cp150:*:*:*:*:*:*:*", "matchCriteriaId": "289B2058-EF26-4965-A713-344E278CC5D4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sl86_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9D7D1187-7ACD-4DCC-ADAD-7653E9BEFC17", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sl86:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "7B437991-E019-41BD-AAA0-BE663CC0BD53", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sl86_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "79272FA8-7DC9-421B-84A0-21ADE2DCB3CA", "versionEndExcluding": "9.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sl86:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "49C49601-7A9B-47AC-AFC0-D37674E520A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sl87_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "55CBD184-8088-473B-8542-F48156BC7369", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sl87:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "F979441B-57A5-427B-B67C-04267322F2F5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sl87_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EC53C37E-C0FE-4BAD-B20A-6B8BB8866310", "versionEndExcluding": "9.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sl87:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "FB997A05-826D-4E4D-9FE9-05EBAFD7C9F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7ss85_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BA3FBC65-B49F-4EA3-982D-4D3FC1046E30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7ss85:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "E229DA19-6D09-4D5C-9FBD-15009F36CFBC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7ss85_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BB620012-EE24-4F5E-A77C-DD865E5CEAF1", "versionEndExcluding": "9.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7ss85:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "2354C161-5D95-43DD-8735-70EAFFB96A35", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7st85_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0E658244-116E-41AF-9638-E0D7CCD4F158", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7st85:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "BE32C2B7-4EA5-44E3-A8A8-122AE1C937C5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7st85_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0E658244-116E-41AF-9638-E0D7CCD4F158", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7st85:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "3DDE4AA1-E4A6-4A86-9826-BBFC7A076F95", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sx85_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6A08C3E4-9299-40B3-8BF2-B9D4A2CCF2C0", "versionEndExcluding": "9.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sx85:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "1A07BC72-9EA0-4D12-A9F8-8E3E8E522F94", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7um85_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DC448F2-0323-4AB4-BCE6-77D19167A33D", "versionEndExcluding": "9.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7um85:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "176D2DA2-3429-4CE3-A7CB-F1EBA54ADC24", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7ut82_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F140ED12-5A00-4B1C-B03A-5E1946980D3B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7ut82:cp100:*:*:*:*:*:*:*", "matchCriteriaId": "01B099AA-77B5-4A8A-BB1E-E30C754A047A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7ut82_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "23E9564B-E66D-40BC-B9CD-5F5E74C6D852", "versionEndExcluding": "9.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7ut82:cp150:*:*:*:*:*:*:*", "matchCriteriaId": "E83EC770-F876-4518-A625-742268FAC1C7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7ut85_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F27AA82-CB13-466F-88F6-87509B01C83E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7ut85:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "563D1E66-BECC-4A8A-A002-3CCCBB7F4DE2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7ut85_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "11D09EFC-CD9D-4CD2-9F35-4FBA023AABD8", "versionEndExcluding": "9.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7ut85:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "CD4C3BC9-0D67-46D0-9033-F5D9BB4E27A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7ut86_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "30CCFCC0-EB3E-4437-9A74-FF5787F69A0E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7ut86:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "99CEF9BE-987E-40A5-A1CA-55A5F52899F5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7ut86_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A1CC685C-7E61-4BDD-B84A-B9F2D11A1AA5", "versionEndExcluding": "9.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7ut86:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "120ADDE5-167C-482F-8DD4-FD90B0C79027", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7ut87_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4EFF5E81-800A-42D9-8899-152E84F28987", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7ut87:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "E830FAFE-60D8-4758-843B-31058C682656", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7ut87_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "12B8CDA6-745F-492B-A132-F99E22743B38", "versionEndExcluding": "9.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7ut87:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "ADEE1942-0B7F-439C-829B-B92F300EC76B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7ve85_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAC0590E-5E3D-41CC-8022-7D845A3DAC98", "versionEndExcluding": "9.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7ve85:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "8A39EFCE-2926-4E58-8521-18DC7A5246B3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7vk87_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DB5FBA4A-650A-4162-90FE-89DA95C09918", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7vk87:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "16390127-25E5-4188-9977-9A1F1A085F33", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7vk87_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8BD59C0-C5AD-472F-B19E-07BFF388B81A", "versionEndExcluding": "9.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7vk87:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "435A96CD-B713-46D0-882D-5F78DD8769A2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_communication_module_ethba2el_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F5E4E495-29B0-43B3-9D47-32380FF4C089", "versionEndExcluding": "9.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_communication_module_ethba2el:-:*:*:*:*:*:*:*", "matchCriteriaId": "1AF3C9BB-2A5E-4C19-BB2B-85466A339559", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_communication_module_ethbb2fo_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3FDEAB27-F510-4C90-83B9-5745785BCF9D", "versionEndExcluding": "9.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_communication_module_ethbb2fo:-:*:*:*:*:*:*:*", "matchCriteriaId": "21DCC99B-0D05-4434-9234-099FE3125971", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_communication_module_ethbd2fo_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A9F4733E-350E-4C18-8CD9-2AFE73AD7277", "versionEndExcluding": "9.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_communication_module_ethbd2fo:-:*:*:*:*:*:*:*", "matchCriteriaId": "ABE48BEE-223F-4E50-B013-36577693B6F5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_compact_7sx800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ECA4C229-AEE6-43C9-BD07-DA54B38BFD7E", "versionEndExcluding": "9.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_compact_7sx800:cp050:*:*:*:*:*:*:*", "matchCriteriaId": "839E7AF3-C681-4882-8F06-8FC1E7B520C2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sa84_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "784DAA71-3A20-4B48-B3ED-EAA65C416E79", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sa84:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "B4E0986C-40CE-4E22-A0C0-84CF9EC3FD57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sd84_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FC1FAB3D-2D2A-493B-9542-14801D6AE6FD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sd84:cp200:*:*:*:*:*:*:*", "matchCriteriaId": "3FB92824-0B69-40E1-B7A1-72DDCA9B291C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7st86_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "08CA1260-07CC-46C3-9BEE-6280B1E13536", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7st86:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "8B361049-BC5B-40D1-AA49-B7D6F2E8383E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7sx82_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F1DE6142-B1D8-4924-9862-30B03F5CD945", "versionEndExcluding": "9.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7sx82:cp150:*:*:*:*:*:*:*", "matchCriteriaId": "8C83A0C3-3636-4C59-AC23-2B0210714790", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_5_7vu85_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "220636C3-4856-4FDB-A69B-69058F8F5975", "versionEndExcluding": "9.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_5_7vu85:cp300:*:*:*:*:*:*:*", "matchCriteriaId": "2A123C1A-8A14-437D-8591-3F550CE9128D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIPROTEC 5 6MD85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 6MD86 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 6MD89 (CP300) (All versions \u003e= V7.80 \u003c V9.64), SIPROTEC 5 6MU85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7KE85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions \u003c V9.40), SIPROTEC 5 7SA86 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SA87 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions \u003c V9.40), SIPROTEC 5 7SD86 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SD87 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SJ81 (CP100) (All versions \u003c V8.89), SIPROTEC 5 7SJ81 (CP150) (All versions \u003c V9.40), SIPROTEC 5 7SJ82 (CP100) (All versions \u003c V8.89), SIPROTEC 5 7SJ82 (CP150) (All versions \u003c V9.40), SIPROTEC 5 7SJ85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SJ86 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SK82 (CP100) (All versions \u003c V8.89), SIPROTEC 5 7SK82 (CP150) (All versions \u003c V9.40), SIPROTEC 5 7SK85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions \u003c V9.40), SIPROTEC 5 7SL86 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SL87 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SS85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7ST85 (CP300) (All versions \u003e= V7.80 \u003c V9.64), SIPROTEC 5 7ST86 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SX82 (CP150) (All versions \u003c V9.40), SIPROTEC 5 7SX85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7UM85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions \u003c V9.40), SIPROTEC 5 7UT85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7UT86 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7UT87 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7VE85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7VK87 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7VU85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 Communication Module ETH-BA-2EL (All versions \u003c V9.40 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (All versions \u003c V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (All versions \u003c V9.40 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (All versions \u003c V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions \u003c V9.40), SIPROTEC 5 Compact 7SX800 (CP050) (All versions \u003c V9.40). Affected devices lack proper validation of http request parameters of the hosted web service.\r\nAn unauthenticated remote attacker could send specially crafted packets that could cause denial of service condition of the target device." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en \nSIPROTEC 5 6MD85 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40), \nSIPROTEC 5 6MD86 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40), \nSIPROTEC 5 6MD89 ( CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.60), \nSIPROTEC 5 6MU85 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40), \nSIPROTEC 5 7KE85 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40), \nSIPROTEC 5 7SA82 (CP100) (Todas las versiones), \nSIPROTEC 5 7SA82 (CP150) (Todas las versiones \u0026lt; V9.40), \nSIPROTEC 5 7SA86 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40 ), \nSIPROTEC 5 7SA87 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40), \nSIPROTEC 5 7SD82 (CP100) (Todas las versiones), \nSIPROTEC 5 7SD82 (CP150) (Todas las versiones \u0026lt; V9.40), \nSIPROTEC 5 7SD86 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40), \nSIPROTEC 5 7SD87 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40), \nSIPROTEC 5 7SJ81 (CP100) (Todas las versiones), \nSIPROTEC 5 7SJ81 (CP150) (Todas las versiones \u0026lt; V9.40), \nSIPROTEC 5 7SJ82 (CP100) (Todas las versiones), \nSIPROTEC 5 7SJ82 (CP150) (Todas las versiones \u0026lt; V9.40), \nSIPROTEC 5 7SJ85 (CP300) (Todas las versiones \u0026gt; = V7.80 \u0026lt; V9.40), \nSIPROTEC 5 7SJ86 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40), \nSIPROTEC 5 7SK82 (CP100) (Todas las versiones), \nSIPROTEC 5 7SK82 (CP150) (Todas las versiones \u0026lt; V9.40), \nSIPROTEC 5 7SK85 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40), \nSIPROTEC 5 7SL82 (CP100) (Todas las versiones), \nSIPROTEC 5 7SL82 (CP150) (Todas las versiones \u0026lt; V9.40 ), \nSIPROTEC 5 7SL86 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40), \nSIPROTEC 5 7SL87 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40), \nSIPROTEC 5 7SS85 (CP300) (Todas versiones \u0026gt;= V7.80 \u0026lt; V9.40), \nSIPROTEC 5 7ST85 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.60), \nSIPROTEC 5 7ST86 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40 ), \nSIPROTEC 5 7SX82 (CP150) (Todas las versiones \u0026lt; V9.40), \nSIPROTEC 5 7SX85 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40), \nSIPROTEC 5 7UM85 (CP300) (Todas las versiones \u0026gt;= V7. 80 \u0026lt; V9.40), \nSIPROTEC 5 7UT82 (CP100) (Todas las versiones), \nSIPROTEC 5 7UT82 (CP150) (Todas las versiones \u0026lt; V9.40), \nSIPROTEC 5 7UT85 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9. 40), \nSIPROTEC 5 7UT86 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40), \nSIPROTEC 5 7UT87 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40), \nSIPROTEC 5 7VE85 (CP300) ( Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40), \nSIPROTEC 5 7VK87 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40), \nSIPROTEC 5 7VU85 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9. 40), \nSIPROTEC 5 Communication Module ETH-BA-2EL (todas las versiones \u0026lt; V9.40), \nSIPROTEC 5 Communication Module ETH-BB-2FO (todas las versiones \u0026lt; V9.40), \nSIPROTEC 5 Communication Module ETH-BD-2FO (todas versiones \u0026lt; V9.40), \nSIPROTEC 5 Compact 7SX800 (CP050) (Todas las versiones \u0026lt; V9.40). \n\nLos dispositivos afectados carecen de una validaci\u00f3n adecuada de los par\u00e1metros de solicitud http del servicio web alojado. Un atacante remoto no autenticado podr\u00eda enviar paquetes especialmente manipulados que podr\u00edan provocar una condici\u00f3n de denegaci\u00f3n de servicio del dispositivo objetivo." } ], "id": "CVE-2023-28766", "lastModified": "2024-11-21T07:55:57.867", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "productcert@siemens.com", "type": "Primary" } ] }, "published": "2023-04-11T10:15:18.337", "references": [ { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-322980.html" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-322980.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/html/ssa-322980.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-322980.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-476" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }