Vulnerabilites related to siemens - siprotec_5_7sa84
cve-2023-28766
Vulnerability from cvelistv5
Published
2023-04-11 09:03
Modified
2024-08-02 13:51
Summary
A vulnerability has been identified in SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V9.64), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions < V9.40), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions < V9.40), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.40), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.40), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SK82 (CP100) (All versions < V8.89), SIPROTEC 5 7SK82 (CP150) (All versions < V9.40), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions < V9.40), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7ST85 (CP300) (All versions >= V7.80 < V9.64), SIPROTEC 5 7ST86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SX82 (CP150) (All versions < V9.40), SIPROTEC 5 7SX85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions < V9.40), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7VU85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 Communication Module ETH-BA-2EL (All versions < V9.40 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (All versions < V9.40 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions < V9.40), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.40). Affected devices lack proper validation of http request parameters of the hosted web service. An unauthenticated remote attacker could send specially crafted packets that could cause denial of service condition of the target device.
Impacted products
Vendor Product Version
Siemens SIPROTEC 5 6MD85 (CP300) Version: V7.80   < V9.40
Create a notification for this product.
   Siemens SIPROTEC 5 6MD86 (CP300) Version: V7.80   < V9.40
Create a notification for this product.
   Siemens SIPROTEC 5 6MD89 (CP300) Version: V7.80   < V9.64
Create a notification for this product.
   Siemens SIPROTEC 5 6MU85 (CP300) Version: V7.80   < V9.40
Create a notification for this product.
   Siemens SIPROTEC 5 7KE85 (CP300) Version: V7.80   < V9.40
Create a notification for this product.
   Siemens SIPROTEC 5 7SA82 (CP100) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7SA82 (CP150) Version: 0   < V9.40
Create a notification for this product.
   Siemens SIPROTEC 5 7SA86 (CP300) Version: V7.80   < V9.40
Create a notification for this product.
   Siemens SIPROTEC 5 7SA87 (CP300) Version: V7.80   < V9.40
Create a notification for this product.
   Siemens SIPROTEC 5 7SD82 (CP100) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7SD82 (CP150) Version: 0   < V9.40
Create a notification for this product.
   Siemens SIPROTEC 5 7SD86 (CP300) Version: V7.80   < V9.40
Create a notification for this product.
   Siemens SIPROTEC 5 7SD87 (CP300) Version: V7.80   < V9.40
Create a notification for this product.
   Siemens SIPROTEC 5 7SJ81 (CP100) Version: 0   < V8.89
Create a notification for this product.
   Siemens SIPROTEC 5 7SJ81 (CP150) Version: 0   < V9.40
Create a notification for this product.
   Siemens SIPROTEC 5 7SJ82 (CP100) Version: 0   < V8.89
Create a notification for this product.
   Siemens SIPROTEC 5 7SJ82 (CP150) Version: 0   < V9.40
Create a notification for this product.
   Siemens SIPROTEC 5 7SJ85 (CP300) Version: V7.80   < V9.40
Create a notification for this product.
   Siemens SIPROTEC 5 7SJ86 (CP300) Version: V7.80   < V9.40
Create a notification for this product.
   Siemens SIPROTEC 5 7SK82 (CP100) Version: 0   < V8.89
Create a notification for this product.
   Siemens SIPROTEC 5 7SK82 (CP150) Version: 0   < V9.40
Create a notification for this product.
   Siemens SIPROTEC 5 7SK85 (CP300) Version: V7.80   < V9.40
Create a notification for this product.
   Siemens SIPROTEC 5 7SL82 (CP100) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7SL82 (CP150) Version: 0   < V9.40
Create a notification for this product.
   Siemens SIPROTEC 5 7SL86 (CP300) Version: V7.80   < V9.40
Create a notification for this product.
   Siemens SIPROTEC 5 7SL87 (CP300) Version: V7.80   < V9.40
Create a notification for this product.
   Siemens SIPROTEC 5 7SS85 (CP300) Version: V7.80   < V9.40
Create a notification for this product.
   Siemens SIPROTEC 5 7ST85 (CP300) Version: V7.80   < V9.64
Create a notification for this product.
   Siemens SIPROTEC 5 7ST86 (CP300) Version: V7.80   < V9.40
Create a notification for this product.
   Siemens SIPROTEC 5 7SX82 (CP150) Version: 0   < V9.40
Create a notification for this product.
   Siemens SIPROTEC 5 7SX85 (CP300) Version: V7.80   < V9.40
Create a notification for this product.
   Siemens SIPROTEC 5 7UM85 (CP300) Version: V7.80   < V9.40
Create a notification for this product.
   Siemens SIPROTEC 5 7UT82 (CP100) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7UT82 (CP150) Version: 0   < V9.40
Create a notification for this product.
   Siemens SIPROTEC 5 7UT85 (CP300) Version: V7.80   < V9.40
Create a notification for this product.
   Siemens SIPROTEC 5 7UT86 (CP300) Version: V7.80   < V9.40
Create a notification for this product.
   Siemens SIPROTEC 5 7UT87 (CP300) Version: V7.80   < V9.40
Create a notification for this product.
   Siemens SIPROTEC 5 7VE85 (CP300) Version: V7.80   < V9.40
Create a notification for this product.
   Siemens SIPROTEC 5 7VK87 (CP300) Version: V7.80   < V9.40
Create a notification for this product.
   Siemens SIPROTEC 5 7VU85 (CP300) Version: V7.80   < V9.40
Create a notification for this product.
   Siemens SIPROTEC 5 Communication Module ETH-BA-2EL Version: 0   < V9.40
Create a notification for this product.
   Siemens SIPROTEC 5 Communication Module ETH-BA-2EL Version: 0   < V8.89
Create a notification for this product.
   Siemens SIPROTEC 5 Communication Module ETH-BB-2FO Version: 0   < V9.40
Create a notification for this product.
   Siemens SIPROTEC 5 Communication Module ETH-BB-2FO Version: 0   < V8.89
Create a notification for this product.
   Siemens SIPROTEC 5 Communication Module ETH-BD-2FO Version: 0   < V9.40
Create a notification for this product.
   Siemens SIPROTEC 5 Compact 7SX800 (CP050) Version: 0   < V9.40
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T13:51:38.336Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-322980.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-322980.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 6MD85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.40",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 6MD86 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.40",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 6MD89 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.64",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 6MU85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.40",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7KE85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.40",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SA82 (CP100)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SA82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.40",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SA86 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.40",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SA87 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.40",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SD82 (CP100)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SD82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.40",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SD86 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.40",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SD87 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.40",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SJ81 (CP100)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.89",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SJ81 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.40",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SJ82 (CP100)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.89",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SJ82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.40",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SJ85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.40",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SJ86 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.40",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SK82 (CP100)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.89",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SK82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.40",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SK85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.40",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SL82 (CP100)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SL82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.40",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SL86 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.40",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SL87 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.40",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SS85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.40",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7ST85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.64",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7ST86 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.40",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SX82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.40",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SX85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.40",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UM85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.40",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UT82 (CP100)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UT82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.40",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UT85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.40",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UT86 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.40",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UT87 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.40",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7VE85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.40",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7VK87 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.40",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7VU85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.40",
              "status": "affected",
              "version": "V7.80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 Communication Module ETH-BA-2EL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.40",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 Communication Module ETH-BA-2EL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.89",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 Communication Module ETH-BB-2FO",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.40",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 Communication Module ETH-BB-2FO",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.89",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 Communication Module ETH-BD-2FO",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.40",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 Compact 7SX800 (CP050)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.40",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIPROTEC 5 6MD85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 6MD86 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 6MD89 (CP300) (All versions \u003e= V7.80 \u003c V9.64), SIPROTEC 5 6MU85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7KE85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions \u003c V9.40), SIPROTEC 5 7SA86 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SA87 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions \u003c V9.40), SIPROTEC 5 7SD86 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SD87 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SJ81 (CP100) (All versions \u003c V8.89), SIPROTEC 5 7SJ81 (CP150) (All versions \u003c V9.40), SIPROTEC 5 7SJ82 (CP100) (All versions \u003c V8.89), SIPROTEC 5 7SJ82 (CP150) (All versions \u003c V9.40), SIPROTEC 5 7SJ85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SJ86 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SK82 (CP100) (All versions \u003c V8.89), SIPROTEC 5 7SK82 (CP150) (All versions \u003c V9.40), SIPROTEC 5 7SK85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions \u003c V9.40), SIPROTEC 5 7SL86 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SL87 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SS85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7ST85 (CP300) (All versions \u003e= V7.80 \u003c V9.64), SIPROTEC 5 7ST86 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SX82 (CP150) (All versions \u003c V9.40), SIPROTEC 5 7SX85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7UM85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions \u003c V9.40), SIPROTEC 5 7UT85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7UT86 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7UT87 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7VE85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7VK87 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7VU85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 Communication Module ETH-BA-2EL (All versions \u003c V9.40 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (All versions \u003c V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (All versions \u003c V9.40 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (All versions \u003c V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions \u003c V9.40), SIPROTEC 5 Compact 7SX800 (CP050) (All versions \u003c V9.40). Affected devices lack proper validation of http request parameters of the hosted web service.\r\nAn unauthenticated remote attacker could send specially crafted packets that could cause denial of service condition of the target device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-476",
              "description": "CWE-476: NULL Pointer Dereference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-15T07:23:35.884Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-322980.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-322980.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-28766",
    "datePublished": "2023-04-11T09:03:05.547Z",
    "dateReserved": "2023-03-23T09:09:31.711Z",
    "dateUpdated": "2024-08-02T13:51:38.336Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Vulnerability from fkie_nvd
Published
2023-04-11 10:15
Modified
2024-11-21 07:55
Summary
A vulnerability has been identified in SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V9.64), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions < V9.40), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions < V9.40), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.40), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.40), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SK82 (CP100) (All versions < V8.89), SIPROTEC 5 7SK82 (CP150) (All versions < V9.40), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions < V9.40), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7ST85 (CP300) (All versions >= V7.80 < V9.64), SIPROTEC 5 7ST86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SX82 (CP150) (All versions < V9.40), SIPROTEC 5 7SX85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions < V9.40), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7VU85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 Communication Module ETH-BA-2EL (All versions < V9.40 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (All versions < V9.40 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions < V9.40), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.40). Affected devices lack proper validation of http request parameters of the hosted web service. An unauthenticated remote attacker could send specially crafted packets that could cause denial of service condition of the target device.
Impacted products
Vendor Product Version
siemens siprotec_5_6md85_firmware *
siemens siprotec_5_6md85 cp200
siemens siprotec_5_6md85_firmware *
siemens siprotec_5_6md85 cp300
siemens siprotec_5_6md86_firmware *
siemens siprotec_5_6md86 cp200
siemens siprotec_5_6md86_firmware *
siemens siprotec_5_6md86 cp300
siemens siprotec_5_6md89_firmware *
siemens siprotec_5_6md89 cp300
siemens siprotec_5_6mu85_firmware *
siemens siprotec_5_6mu85 cp300
siemens siprotec_5_7ke85_firmware *
siemens siprotec_5_7ke85 cp200
siemens siprotec_5_7ke85_firmware *
siemens siprotec_5_7ke85 cp300
siemens siprotec_5_7sa82_firmware *
siemens siprotec_5_7sa82 cp100
siemens siprotec_5_7sa82_firmware *
siemens siprotec_5_7sa82 cp150
siemens siprotec_5_7sa86_firmware *
siemens siprotec_5_7sa86 cp200
siemens siprotec_5_7sa86_firmware *
siemens siprotec_5_7sa86 cp300
siemens siprotec_5_7sa87_firmware *
siemens siprotec_5_7sa87 cp200
siemens siprotec_5_7sa87_firmware *
siemens siprotec_5_7sa87 cp300
siemens siprotec_5_7sd82_firmware *
siemens siprotec_5_7sd82 cp100
siemens siprotec_5_7sd82_firmware *
siemens siprotec_5_7sd82 cp150
siemens siprotec_5_7sd86_firmware *
siemens siprotec_5_7sd86 cp200
siemens siprotec_5_7sd86_firmware *
siemens siprotec_5_7sd86 cp300
siemens siprotec_5_7sd87_firmware *
siemens siprotec_5_7sd87 cp200
siemens siprotec_5_7sd87_firmware *
siemens siprotec_5_7sd87 cp300
siemens siprotec_5_7sj81_firmware *
siemens siprotec_5_7sj81 cp100
siemens siprotec_5_7sj81_firmware *
siemens siprotec_5_7sj81 cp150
siemens siprotec_5_7sj82_firmware *
siemens siprotec_5_7sj82 cp100
siemens siprotec_5_7sj82_firmware *
siemens siprotec_5_7sj82 cp150
siemens siprotec_5_7sj85_firmware *
siemens siprotec_5_7sj85 cp200
siemens siprotec_5_7sj85_firmware *
siemens siprotec_5_7sj85 cp300
siemens siprotec_5_7sj86_firmware *
siemens siprotec_5_7sj86 cp200
siemens siprotec_5_7sj86_firmware *
siemens siprotec_5_7sj86 cp300
siemens siprotec_5_7sk82_firmware *
siemens siprotec_5_7sk82 cp100
siemens siprotec_5_7sk82_firmware *
siemens siprotec_5_7sk82 cp150
siemens siprotec_5_7sk85_firmware *
siemens siprotec_5_7sk85 cp200
siemens siprotec_5_7sk85_firmware *
siemens siprotec_5_7sk85 cp300
siemens siprotec_5_7sl82_firmware *
siemens siprotec_5_7sl82 cp100
siemens siprotec_5_7sl82_firmware *
siemens siprotec_5_7sl82 cp150
siemens siprotec_5_7sl86_firmware *
siemens siprotec_5_7sl86 cp200
siemens siprotec_5_7sl86_firmware *
siemens siprotec_5_7sl86 cp300
siemens siprotec_5_7sl87_firmware *
siemens siprotec_5_7sl87 cp200
siemens siprotec_5_7sl87_firmware *
siemens siprotec_5_7sl87 cp300
siemens siprotec_5_7ss85_firmware *
siemens siprotec_5_7ss85 cp200
siemens siprotec_5_7ss85_firmware *
siemens siprotec_5_7ss85 cp300
siemens siprotec_5_7st85_firmware *
siemens siprotec_5_7st85 cp200
siemens siprotec_5_7st85_firmware *
siemens siprotec_5_7st85 cp300
siemens siprotec_5_7sx85_firmware *
siemens siprotec_5_7sx85 cp300
siemens siprotec_5_7um85_firmware *
siemens siprotec_5_7um85 cp300
siemens siprotec_5_7ut82_firmware *
siemens siprotec_5_7ut82 cp100
siemens siprotec_5_7ut82_firmware *
siemens siprotec_5_7ut82 cp150
siemens siprotec_5_7ut85_firmware *
siemens siprotec_5_7ut85 cp200
siemens siprotec_5_7ut85_firmware *
siemens siprotec_5_7ut85 cp300
siemens siprotec_5_7ut86_firmware *
siemens siprotec_5_7ut86 cp200
siemens siprotec_5_7ut86_firmware *
siemens siprotec_5_7ut86 cp300
siemens siprotec_5_7ut87_firmware *
siemens siprotec_5_7ut87 cp200
siemens siprotec_5_7ut87_firmware *
siemens siprotec_5_7ut87 cp300
siemens siprotec_5_7ve85_firmware *
siemens siprotec_5_7ve85 cp300
siemens siprotec_5_7vk87_firmware *
siemens siprotec_5_7vk87 cp200
siemens siprotec_5_7vk87_firmware *
siemens siprotec_5_7vk87 cp300
siemens siprotec_5_communication_module_ethba2el_firmware *
siemens siprotec_5_communication_module_ethba2el -
siemens siprotec_5_communication_module_ethbb2fo_firmware *
siemens siprotec_5_communication_module_ethbb2fo -
siemens siprotec_5_communication_module_ethbd2fo_firmware *
siemens siprotec_5_communication_module_ethbd2fo -
siemens siprotec_5_compact_7sx800_firmware *
siemens siprotec_5_compact_7sx800 cp050
siemens siprotec_5_7sa84_firmware *
siemens siprotec_5_7sa84 cp200
siemens siprotec_5_7sd84_firmware *
siemens siprotec_5_7sd84 cp200
siemens siprotec_5_7st86_firmware *
siemens siprotec_5_7st86 cp300
siemens siprotec_5_7sx82_firmware *
siemens siprotec_5_7sx82 cp150
siemens siprotec_5_7vu85_firmware *
siemens siprotec_5_7vu85 cp300



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_6md85_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A0D29DB-48A2-4A00-8B91-F336CC5E4FBE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_6md85:cp200:*:*:*:*:*:*:*",
              "matchCriteriaId": "D4CC1B1C-9EB5-4235-BC3C-D20F39567A69",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_6md85_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C1C2A76-380A-4121-8A73-6A0EF336C8D9",
              "versionEndExcluding": "9.40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_6md85:cp300:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A111316-A19F-47CD-87CB-860C90205A90",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_6md86_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB4BC292-1845-4F87-85EF-FA227CA6BA0A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_6md86:cp200:*:*:*:*:*:*:*",
              "matchCriteriaId": "640BF11A-A17B-4F8B-9D2B-1C1D2D4075BA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_6md86_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D248593-B211-419C-B0EA-883AB75AB191",
              "versionEndExcluding": "9.40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_6md86:cp300:*:*:*:*:*:*:*",
              "matchCriteriaId": "31902FCD-60CD-48BF-9783-423D99AFA813",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_6md89_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "66F75F3B-AA90-463B-AFB0-7D25BDADE3F5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_6md89:cp300:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7084F2B-5865-4ED1-9A6A-E369FC0F1BEB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_6mu85_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "546B673C-FBCC-4449-A1B7-1F5B25AC0F15",
              "versionEndExcluding": "9.40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_6mu85:cp300:*:*:*:*:*:*:*",
              "matchCriteriaId": "1452A607-3CD5-4928-AB0B-169B262703E1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7ke85_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EACDE50E-CD2D-482A-B662-7ACF6BC09311",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7ke85:cp200:*:*:*:*:*:*:*",
              "matchCriteriaId": "FC91C797-4849-4A3B-8100-E2AFE3B4272E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7ke85_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "61C2EDD8-8466-4B0E-BCC3-20FD36C3E114",
              "versionEndExcluding": "9.40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7ke85:cp300:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9C327E6-E0C8-430C-A314-E3D1A60A6809",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7sa82_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1A81C84C-AA56-480C-85FF-8BF0B13BA278",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7sa82:cp100:*:*:*:*:*:*:*",
              "matchCriteriaId": "5BC0B29E-2407-4473-81AB-647648E2B05A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7sa82_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BD24BEEE-813D-48A5-AB8A-D91F095493C8",
              "versionEndExcluding": "9.40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7sa82:cp150:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F61F485-9A80-45A3-BD5A-6526916EC0EA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7sa86_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "90068748-1128-46DA-A0A1-8712FAB0DC7F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7sa86:cp200:*:*:*:*:*:*:*",
              "matchCriteriaId": "08B16445-C707-4D26-8C8A-F1166F85A64B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7sa86_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "952F74A7-D7DA-4253-8850-5449044D42E2",
              "versionEndExcluding": "9.40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7sa86:cp300:*:*:*:*:*:*:*",
              "matchCriteriaId": "8A1DCC8A-5795-4253-A111-5C0EF29FB4B7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7sa87_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9C7421C-2DBE-44A7-83BB-C073F8BAC848",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7sa87:cp200:*:*:*:*:*:*:*",
              "matchCriteriaId": "8FE5CD98-00BD-4AEA-8E3F-2A8AE215AAFA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7sa87_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5532456A-2CED-47E0-961F-1734C5AE5049",
              "versionEndExcluding": "9.40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7sa87:cp300:*:*:*:*:*:*:*",
              "matchCriteriaId": "FDD47A1D-993D-449D-9E23-8D0A5D9B14E1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7sd82_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5F1D59E9-63FA-473C-860E-4ACBD0D0B77F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7sd82:cp100:*:*:*:*:*:*:*",
              "matchCriteriaId": "8D3E5539-B71B-453E-8397-C2A714646D51",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7sd82_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "694F4536-1802-49B5-8823-743F174E844D",
              "versionEndExcluding": "9.40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7sd82:cp150:*:*:*:*:*:*:*",
              "matchCriteriaId": "A9CD8B78-EC91-4507-A0F8-3159935DFE42",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7sd86_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2077F31A-5938-402F-B8AF-44E26CE9634D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7sd86:cp200:*:*:*:*:*:*:*",
              "matchCriteriaId": "C88252DD-84A0-4245-BF75-5A59061FC45F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7sd86_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "46965175-C2E4-492A-9ADC-4653EFB82A66",
              "versionEndExcluding": "9.40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7sd86:cp300:*:*:*:*:*:*:*",
              "matchCriteriaId": "D9C43FC0-76C8-4E52-9AFE-5498F54BF1D5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7sd87_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B9852DB-ED49-415B-AE21-4A974F4FEB74",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7sd87:cp200:*:*:*:*:*:*:*",
              "matchCriteriaId": "3296A090-50EE-4203-8D19-8610D0784037",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7sd87_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "09B91947-FC3A-4E55-BA46-FC79ECED1EB6",
              "versionEndExcluding": "9.40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7sd87:cp300:*:*:*:*:*:*:*",
              "matchCriteriaId": "0E8F3C87-242C-4606-B139-5E64BBAB18D5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7sj81_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B4D0B011-FDC2-4C8B-9DB2-BC3A64A3C9AF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7sj81:cp100:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E8FD72B-E34D-4F7E-ADDF-00955A58299F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7sj81_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8A1F7FD7-EA88-424B-9B5B-25DE5D62BC3A",
              "versionEndExcluding": "9.40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7sj81:cp150:*:*:*:*:*:*:*",
              "matchCriteriaId": "A9EB411D-D0AA-4CDD-BDBB-C3D90F9C53ED",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7sj82_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1C2D1FE4-499C-47C1-B47F-904DE2DC32F0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7sj82:cp100:*:*:*:*:*:*:*",
              "matchCriteriaId": "83094A08-9EFC-4CB8-BFF6-20C17F3E1682",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7sj82_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5B8B47A5-EFFE-4F0E-8BBA-9AEF6D629920",
              "versionEndExcluding": "9.40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7sj82:cp150:*:*:*:*:*:*:*",
              "matchCriteriaId": "DC03BAAF-4507-483F-BF1A-67D8944638A9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7sj85_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "95686A74-193F-4016-AAF0-E24B60735EFC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7sj85:cp200:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AFB2251-7B60-49B6-A9C6-98F47FADE02D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7sj85_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CD3FA333-6DC9-4C9F-81C3-D72AF6DE6DE0",
              "versionEndExcluding": "9.40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7sj85:cp300:*:*:*:*:*:*:*",
              "matchCriteriaId": "466A7D08-762C-4F17-BC44-A81876D24074",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7sj86_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D0913FC3-7E96-4B12-B576-C7592873EC56",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7sj86:cp200:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D2D8944-6F54-4528-A2EE-56F54454F941",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7sj86_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AF51F61C-E0C9-40C0-BB97-AC75DA4894EC",
              "versionEndExcluding": "9.40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7sj86:cp300:*:*:*:*:*:*:*",
              "matchCriteriaId": "B5E80208-787F-49BD-88C9-A5F51D7FA367",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7sk82_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9DD37B3-6C4D-4362-A87B-1DB570B34F71",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7sk82:cp100:*:*:*:*:*:*:*",
              "matchCriteriaId": "08ABC5D4-F8CF-47D7-B482-8E6771DD3213",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7sk82_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AA40B67E-C7F0-4DDA-9C33-058FF2770630",
              "versionEndExcluding": "9.40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7sk82:cp150:*:*:*:*:*:*:*",
              "matchCriteriaId": "E0A9451D-AC58-4CC5-BE77-18DF5C7A4A47",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7sk85_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4393A068-93FF-4597-88BE-DDA15B3CC374",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7sk85:cp200:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF56A2EE-6D67-4C60-88A1-7ADB77B89088",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7sk85_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "52E922D9-98DD-4EB0-9EC4-31A958C29A2C",
              "versionEndExcluding": "9.40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7sk85:cp300:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D919812-54DF-4861-B809-861197F597CF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7sl82_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "44762C83-76EB-48C8-9A17-4EA22814DB83",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7sl82:cp100:*:*:*:*:*:*:*",
              "matchCriteriaId": "4F0D9D58-C0A1-4634-887A-0A62117AAC2C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7sl82_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D673C294-90F4-4132-A0C1-D243105CC29F",
              "versionEndExcluding": "9.40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7sl82:cp150:*:*:*:*:*:*:*",
              "matchCriteriaId": "289B2058-EF26-4965-A713-344E278CC5D4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7sl86_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D7D1187-7ACD-4DCC-ADAD-7653E9BEFC17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7sl86:cp200:*:*:*:*:*:*:*",
              "matchCriteriaId": "7B437991-E019-41BD-AAA0-BE663CC0BD53",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7sl86_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "79272FA8-7DC9-421B-84A0-21ADE2DCB3CA",
              "versionEndExcluding": "9.40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7sl86:cp300:*:*:*:*:*:*:*",
              "matchCriteriaId": "49C49601-7A9B-47AC-AFC0-D37674E520A7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7sl87_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "55CBD184-8088-473B-8542-F48156BC7369",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7sl87:cp200:*:*:*:*:*:*:*",
              "matchCriteriaId": "F979441B-57A5-427B-B67C-04267322F2F5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7sl87_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EC53C37E-C0FE-4BAD-B20A-6B8BB8866310",
              "versionEndExcluding": "9.40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7sl87:cp300:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB997A05-826D-4E4D-9FE9-05EBAFD7C9F4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7ss85_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BA3FBC65-B49F-4EA3-982D-4D3FC1046E30",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7ss85:cp200:*:*:*:*:*:*:*",
              "matchCriteriaId": "E229DA19-6D09-4D5C-9FBD-15009F36CFBC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7ss85_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BB620012-EE24-4F5E-A77C-DD865E5CEAF1",
              "versionEndExcluding": "9.40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7ss85:cp300:*:*:*:*:*:*:*",
              "matchCriteriaId": "2354C161-5D95-43DD-8735-70EAFFB96A35",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7st85_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0E658244-116E-41AF-9638-E0D7CCD4F158",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7st85:cp200:*:*:*:*:*:*:*",
              "matchCriteriaId": "BE32C2B7-4EA5-44E3-A8A8-122AE1C937C5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7st85_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0E658244-116E-41AF-9638-E0D7CCD4F158",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7st85:cp300:*:*:*:*:*:*:*",
              "matchCriteriaId": "3DDE4AA1-E4A6-4A86-9826-BBFC7A076F95",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7sx85_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A08C3E4-9299-40B3-8BF2-B9D4A2CCF2C0",
              "versionEndExcluding": "9.40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7sx85:cp300:*:*:*:*:*:*:*",
              "matchCriteriaId": "1A07BC72-9EA0-4D12-A9F8-8E3E8E522F94",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7um85_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1DC448F2-0323-4AB4-BCE6-77D19167A33D",
              "versionEndExcluding": "9.40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7um85:cp300:*:*:*:*:*:*:*",
              "matchCriteriaId": "176D2DA2-3429-4CE3-A7CB-F1EBA54ADC24",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7ut82_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F140ED12-5A00-4B1C-B03A-5E1946980D3B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7ut82:cp100:*:*:*:*:*:*:*",
              "matchCriteriaId": "01B099AA-77B5-4A8A-BB1E-E30C754A047A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7ut82_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "23E9564B-E66D-40BC-B9CD-5F5E74C6D852",
              "versionEndExcluding": "9.40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7ut82:cp150:*:*:*:*:*:*:*",
              "matchCriteriaId": "E83EC770-F876-4518-A625-742268FAC1C7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7ut85_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5F27AA82-CB13-466F-88F6-87509B01C83E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7ut85:cp200:*:*:*:*:*:*:*",
              "matchCriteriaId": "563D1E66-BECC-4A8A-A002-3CCCBB7F4DE2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7ut85_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "11D09EFC-CD9D-4CD2-9F35-4FBA023AABD8",
              "versionEndExcluding": "9.40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7ut85:cp300:*:*:*:*:*:*:*",
              "matchCriteriaId": "CD4C3BC9-0D67-46D0-9033-F5D9BB4E27A7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7ut86_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "30CCFCC0-EB3E-4437-9A74-FF5787F69A0E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7ut86:cp200:*:*:*:*:*:*:*",
              "matchCriteriaId": "99CEF9BE-987E-40A5-A1CA-55A5F52899F5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7ut86_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1CC685C-7E61-4BDD-B84A-B9F2D11A1AA5",
              "versionEndExcluding": "9.40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7ut86:cp300:*:*:*:*:*:*:*",
              "matchCriteriaId": "120ADDE5-167C-482F-8DD4-FD90B0C79027",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7ut87_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4EFF5E81-800A-42D9-8899-152E84F28987",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7ut87:cp200:*:*:*:*:*:*:*",
              "matchCriteriaId": "E830FAFE-60D8-4758-843B-31058C682656",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7ut87_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "12B8CDA6-745F-492B-A132-F99E22743B38",
              "versionEndExcluding": "9.40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7ut87:cp300:*:*:*:*:*:*:*",
              "matchCriteriaId": "ADEE1942-0B7F-439C-829B-B92F300EC76B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7ve85_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FAC0590E-5E3D-41CC-8022-7D845A3DAC98",
              "versionEndExcluding": "9.40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7ve85:cp300:*:*:*:*:*:*:*",
              "matchCriteriaId": "8A39EFCE-2926-4E58-8521-18DC7A5246B3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7vk87_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DB5FBA4A-650A-4162-90FE-89DA95C09918",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7vk87:cp200:*:*:*:*:*:*:*",
              "matchCriteriaId": "16390127-25E5-4188-9977-9A1F1A085F33",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7vk87_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8BD59C0-C5AD-472F-B19E-07BFF388B81A",
              "versionEndExcluding": "9.40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7vk87:cp300:*:*:*:*:*:*:*",
              "matchCriteriaId": "435A96CD-B713-46D0-882D-5F78DD8769A2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_communication_module_ethba2el_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5E4E495-29B0-43B3-9D47-32380FF4C089",
              "versionEndExcluding": "9.40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_communication_module_ethba2el:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1AF3C9BB-2A5E-4C19-BB2B-85466A339559",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_communication_module_ethbb2fo_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3FDEAB27-F510-4C90-83B9-5745785BCF9D",
              "versionEndExcluding": "9.40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_communication_module_ethbb2fo:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "21DCC99B-0D05-4434-9234-099FE3125971",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_communication_module_ethbd2fo_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A9F4733E-350E-4C18-8CD9-2AFE73AD7277",
              "versionEndExcluding": "9.40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_communication_module_ethbd2fo:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ABE48BEE-223F-4E50-B013-36577693B6F5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_compact_7sx800_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "ECA4C229-AEE6-43C9-BD07-DA54B38BFD7E",
              "versionEndExcluding": "9.40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_compact_7sx800:cp050:*:*:*:*:*:*:*",
              "matchCriteriaId": "839E7AF3-C681-4882-8F06-8FC1E7B520C2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7sa84_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "784DAA71-3A20-4B48-B3ED-EAA65C416E79",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7sa84:cp200:*:*:*:*:*:*:*",
              "matchCriteriaId": "B4E0986C-40CE-4E22-A0C0-84CF9EC3FD57",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7sd84_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FC1FAB3D-2D2A-493B-9542-14801D6AE6FD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7sd84:cp200:*:*:*:*:*:*:*",
              "matchCriteriaId": "3FB92824-0B69-40E1-B7A1-72DDCA9B291C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7st86_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "08CA1260-07CC-46C3-9BEE-6280B1E13536",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7st86:cp300:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B361049-BC5B-40D1-AA49-B7D6F2E8383E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7sx82_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F1DE6142-B1D8-4924-9862-30B03F5CD945",
              "versionEndExcluding": "9.40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7sx82:cp150:*:*:*:*:*:*:*",
              "matchCriteriaId": "8C83A0C3-3636-4C59-AC23-2B0210714790",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_7vu85_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "220636C3-4856-4FDB-A69B-69058F8F5975",
              "versionEndExcluding": "9.40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_5_7vu85:cp300:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A123C1A-8A14-437D-8591-3F550CE9128D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIPROTEC 5 6MD85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 6MD86 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 6MD89 (CP300) (All versions \u003e= V7.80 \u003c V9.64), SIPROTEC 5 6MU85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7KE85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions \u003c V9.40), SIPROTEC 5 7SA86 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SA87 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions \u003c V9.40), SIPROTEC 5 7SD86 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SD87 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SJ81 (CP100) (All versions \u003c V8.89), SIPROTEC 5 7SJ81 (CP150) (All versions \u003c V9.40), SIPROTEC 5 7SJ82 (CP100) (All versions \u003c V8.89), SIPROTEC 5 7SJ82 (CP150) (All versions \u003c V9.40), SIPROTEC 5 7SJ85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SJ86 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SK82 (CP100) (All versions \u003c V8.89), SIPROTEC 5 7SK82 (CP150) (All versions \u003c V9.40), SIPROTEC 5 7SK85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions \u003c V9.40), SIPROTEC 5 7SL86 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SL87 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SS85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7ST85 (CP300) (All versions \u003e= V7.80 \u003c V9.64), SIPROTEC 5 7ST86 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7SX82 (CP150) (All versions \u003c V9.40), SIPROTEC 5 7SX85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7UM85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions \u003c V9.40), SIPROTEC 5 7UT85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7UT86 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7UT87 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7VE85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7VK87 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 7VU85 (CP300) (All versions \u003e= V7.80 \u003c V9.40), SIPROTEC 5 Communication Module ETH-BA-2EL (All versions \u003c V9.40 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (All versions \u003c V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (All versions \u003c V9.40 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (All versions \u003c V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions \u003c V9.40), SIPROTEC 5 Compact 7SX800 (CP050) (All versions \u003c V9.40). Affected devices lack proper validation of http request parameters of the hosted web service.\r\nAn unauthenticated remote attacker could send specially crafted packets that could cause denial of service condition of the target device."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en \nSIPROTEC 5 6MD85 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40), \nSIPROTEC 5 6MD86 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40), \nSIPROTEC 5 6MD89 ( CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.60), \nSIPROTEC 5 6MU85 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40), \nSIPROTEC 5 7KE85 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40), \nSIPROTEC 5 7SA82 (CP100) (Todas las versiones), \nSIPROTEC 5 7SA82 (CP150) (Todas las versiones \u0026lt; V9.40), \nSIPROTEC 5 7SA86 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40 ), \nSIPROTEC 5 7SA87 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40), \nSIPROTEC 5 7SD82 (CP100) (Todas las versiones), \nSIPROTEC 5 7SD82 (CP150) (Todas las versiones \u0026lt; V9.40), \nSIPROTEC 5 7SD86 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40), \nSIPROTEC 5 7SD87 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40), \nSIPROTEC 5 7SJ81 (CP100) (Todas las versiones), \nSIPROTEC 5 7SJ81 (CP150) (Todas las versiones \u0026lt; V9.40), \nSIPROTEC 5 7SJ82 (CP100) (Todas las versiones), \nSIPROTEC 5 7SJ82 (CP150) (Todas las versiones \u0026lt; V9.40), \nSIPROTEC 5 7SJ85 (CP300) (Todas las versiones \u0026gt; = V7.80 \u0026lt; V9.40), \nSIPROTEC 5 7SJ86 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40), \nSIPROTEC 5 7SK82 (CP100) (Todas las versiones), \nSIPROTEC 5 7SK82 (CP150) (Todas las versiones \u0026lt; V9.40), \nSIPROTEC 5 7SK85 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40), \nSIPROTEC 5 7SL82 (CP100) (Todas las versiones), \nSIPROTEC 5 7SL82 (CP150) (Todas las versiones \u0026lt; V9.40 ), \nSIPROTEC 5 7SL86 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40), \nSIPROTEC 5 7SL87 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40), \nSIPROTEC 5 7SS85 (CP300) (Todas versiones \u0026gt;= V7.80 \u0026lt; V9.40), \nSIPROTEC 5 7ST85 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.60), \nSIPROTEC 5 7ST86 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40 ), \nSIPROTEC 5 7SX82 (CP150) (Todas las versiones \u0026lt; V9.40), \nSIPROTEC 5 7SX85 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40), \nSIPROTEC 5 7UM85 (CP300) (Todas las versiones \u0026gt;= V7. 80 \u0026lt; V9.40), \nSIPROTEC 5 7UT82 (CP100) (Todas las versiones), \nSIPROTEC 5 7UT82 (CP150) (Todas las versiones \u0026lt; V9.40), \nSIPROTEC 5 7UT85 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9. 40), \nSIPROTEC 5 7UT86 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40), \nSIPROTEC 5 7UT87 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40), \nSIPROTEC 5 7VE85 (CP300) ( Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40), \nSIPROTEC 5 7VK87 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.40), \nSIPROTEC 5 7VU85 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9. 40), \nSIPROTEC 5 Communication Module ETH-BA-2EL (todas las versiones \u0026lt; V9.40), \nSIPROTEC 5 Communication Module ETH-BB-2FO (todas las versiones \u0026lt; V9.40), \nSIPROTEC 5 Communication Module ETH-BD-2FO (todas versiones \u0026lt; V9.40), \nSIPROTEC 5 Compact 7SX800 (CP050) (Todas las versiones \u0026lt; V9.40). \n\nLos dispositivos afectados carecen de una validaci\u00f3n adecuada de los par\u00e1metros de solicitud http del servicio web alojado. Un atacante remoto no autenticado podr\u00eda enviar paquetes especialmente manipulados que podr\u00edan provocar una condici\u00f3n de denegaci\u00f3n de servicio del dispositivo objetivo."
    }
  ],
  "id": "CVE-2023-28766",
  "lastModified": "2024-11-21T07:55:57.867",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-04-11T10:15:18.337",
  "references": [
    {
      "source": "productcert@siemens.com",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-322980.html"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-322980.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-322980.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-322980.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-476"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}