A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0891D85-C5F4-4CD2-8EFA-84356CE36654", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:-:*:*:*:*:*:*", "matchCriteriaId": "E0005A53-33AD-47AF-B172-CAF423DE213F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update1:*:*:*:*:*:*", "matchCriteriaId": "9696B0D9-5A66-4747-9437-791EAC150DDA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update2:*:*:*:*:*:*", "matchCriteriaId": "F6AC2BA5-1668-4B71-8812-925AC6554F5A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update3:*:*:*:*:*:*", "matchCriteriaId": "047D0868-3DA6-41CF-A6F9-D15668D536FB", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sh150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0F1FAFD2-1E4D-44F3-87A1-8A1380B980BC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sh150:-:*:*:*:*:*:*:*", "matchCriteriaId": "EBC7AA8D-9046-4111-A263-38343997F984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm150i_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D6067521-A21D-4B2A-AFB2-2E033F66B63E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm150i:-:*:*:*:*:*:*:*", "matchCriteriaId": "A44DEAD8-8DB8-41CC-9495-B842BE76EA8F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4BF9157D-0089-4569-9AA1-4DEE94140D25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*", "matchCriteriaId": "BF977545-395A-4C34-BB22-A1047B5B6E85", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4D780400-0AA8-449C-B754-7167CA878D3D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DED7F33B-D475-4232-8683-48554A6729F7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "61CD50EE-6C46-445E-8D46-82768CAAC305", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E032554B-7F51-4482-AF55-743FFB5AC352", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "C6619B0F-7CDC-40A6-89B2-C6067AF45214", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CFFE3048-EEB0-48A0-BED0-8647284B022B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*", "matchCriteriaId": "444DD77F-DB65-4766-A89D-7A679B4CA1E1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33B7E1DE-61B5-4CFC-8640-EB8029CD79D6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "2AE231E2-2B2B-407A-BF7A-9EA35F394229", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "244D9B27-649C-4983-B374-6A8774771AC5", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "A2530BB3-484C-4D24-82F6-15967C8B7B32", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "B5A1FACE-E693-4FDA-944D-0B7F500007B6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D7FB4AA4-1F48-4A25-AA21-5F867A38D23E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "6A673BD0-96B5-48CA-B060-A5D01687A764", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "428B633D-55FF-4DB8-B6DD-5E4EEE52A44C", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:*:*:*:*:*:*:*", "matchCriteriaId": "C33A64DD-22A2-4260-929F-7595CD037823", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "9756D206-E295-4B0C-B159-F9A953342E37", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "82D6FBBF-FD9B-4AFA-B3E1-8E3341948A37", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D43D2191-DBBD-4F7A-B02A-3DCEE46BF904", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "23C6AD3C-C15B-4B67-88D1-236C10BB12CF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FEE4201E-E660-4B3E-91EC-B6A7DC35C189", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "F2D6D924-858A-4542-BCD0-A5631F941039", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "309E4D56-6D39-4E8F-8312-FF178B721392", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "EDB63639-3101-4F60-8193-EF219D99C128", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "4C6C83EE-3DC7-4CB3-8148-CB24A825274E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C6C72B0-17D7-491E-816A-AF855166A90B", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "322584EF-72C0-4032-A02B-FDFFDCCE3FDE", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "C3D5F1BA-2BEA-40A9-8D5B-A612D467C40C", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D14DE5C7-318A-4D08-BB39-1E43F624816A", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "FCDAF23F-9272-4DC5-8D46-37FAC08950CC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "21FB0305-DF87-42FF-BACA-E8255EA74AA9", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "BAA5B299-A45A-4918-AB8F-03A476CEDA17", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "0C29FD64-C041-4269-BC52-8F91321BC247", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "7182C6C0-7DAD-4446-B14E-8EF46FB0CFA9", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "44F6F972-26AF-4A6E-AAD9-B30EBDF52465", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E57B8F3D-5E02-4F0F-9927-9D7C336EBE56", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "845C78A9-AE0F-42B9-9E25-47F541DF5196", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "B23096F5-3546-41D8-BE30-8698BC0C9B42", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D7C5AF13-69FF-444F-B84A-130D7413B307", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "66A17FC6-B6AE-4915-8069-68B41F3C87E2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4C618736-1382-4515-A295-6EC67A2731EA", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "BC0AD5A8-768E-4747-AD89-B924D369565E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "4C2FD1E4-4A01-4BFB-9D2A-5A030C37BD96", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "0AA5C3DC-E67F-4773-B32C-6B362C94BCBE", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "C96C7676-9A0D-46B5-9C49-5F5CE873E2C1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AF42C3EA-84A5-4419-ACBA-6A2F8DB994E2", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "105CCE4B-D8F9-43EA-9089-CEE16A410751", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "7C163E7E-C9E3-4FBD-885A-C2E7FB8B845F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "2CD3DD84-BDAC-4583-BD61-799A5F01A5B4", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "0A4F6758-0B36-4546-A7A7-A4C71B63772E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "12A613F7-4EA4-40FF-931F-EF3C477300DA", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "4B048552-A26D-419E-9EEA-9AFD9457B70B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "0E4E1016-F217-4B75-83D7-F73B1C5A54F9", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "EF2F6982-2C38-4F9B-87A4-AE4404197B7A", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "7745AA84-BC12-4DBD-90A6-DA294EADB7BF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "67CFFD89-1FF2-4F25-A5AB-D6FF8F721132", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "BA4B198A-8288-459D-9586-CD402DE23023", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "AC4FDB83-702A-41D5-B2A5-BDA58B7E13D2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "D972823A-1128-4222-8910-9CA3D38B472F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "A05007D7-3C49-4192-ABDF-FE94BA7FD1D1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "869AD837-79B1-4F76-947B-7DCAD172BDC0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "5C152EB8-A13A-4F16-994A-B6D93A017CC3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "42F38FBA-7D23-4CB2-9A2D-45616E2A2DFB", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "553C9A57-A9D2-47F9-ABA8-042B05DE46C7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "8F5F3B33-2A82-4CDF-A678-76DE13F256D7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "9FE49F2D-B904-4E48-AAFD-669141B570F6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "729F784C-9AC0-4231-A75A-1FA8373FA31F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "FA61AC05-061D-4EE7-BFEF-568F30B9B883", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "374BAF2F-0A32-4F1A-B838-894F9E9D3E0F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C636FCD-78AE-4FA2-95E5-2BBD5A88DA68", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "FDE42199-9152-41A3-BE56-E6789315CF28", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "040F990F-F3C2-46EF-9E40-FD136A19575F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "748BFFBC-56BD-42EC-9B5F-0752D2A70D17", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "B37490B0-A214-4A62-9B67-934048921C1E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "3D7B9F45-5749-4F36-961D-6C5D650ADA07", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "F544593D-368B-4EC1-8448-8C2BA1301216", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A9D26D9F-7081-42B2-8AE4-D04E8429B88D", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "5F902732-9944-4821-BCFB-9937D1301FF6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "B0C061AC-3E64-4667-A0E7-DD58B2E5A014", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "3EECF743-25E8-4483-AA68-B304B38A9290", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "2F557157-AAD6-4601-84C2-2F8574F23683", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "A6BF6644-AF29-4541-9D6A-D07D0CC026F0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "C4FD5396-8094-4DD0-BE7B-0FB6CC6D45F1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A8EC6926-258F-4F5C-88D2-33FE363340DB", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "97E283EF-A950-40E7-91C7-839203A333A5", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "B5B130C2-28B8-464C-981C-B5662B4B4309", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "79407355-4181-4082-A661-C27734D95363", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "8989C7D4-5246-443E-B6E4-8E91462B2E96", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "2BFBC5B2-B00B-4FCD-86B1-A187122035AB", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "B47671A7-A8DB-4DA2-9076-78708C7F1C42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D9CF819-E06C-4EAA-85B3-AC40E039D485", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "4AF727E5-7849-4980-8AA5-7469FD52DF86", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "F36ABC58-C9FE-4F4A-AB81-26D48A79FFD2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "A87DD9FF-9CA3-4AE2-8C86-C30A779E0CE6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "891AF48F-1F4D-4AB8-AE66-FBABDD2CAA76", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "5052CB07-626A-46C4-8966-B8C9325A3BB3", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "6CD47CC7-1414-42C9-94C6-9DBC2C1D9CBE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B28FB484-526A-437E-80E3-B62F54F1BEF6", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "61DFC57F-0359-4B4A-A13C-067B21D3DA7B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "81CE70BF-EBBE-4CD7-999C-25662670EFCB", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "034B7CFC-1234-4914-8C84-7E5BD5FB6E4D", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "221EB3AE-1420-46F8-9EAD-1914503B0435", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "5F9A416C-277F-44B0-A74C-263CB0C37D03", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "FA858127-69A0-4280-80A8-65E0778A90AD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "66FC2264-7DDD-4BEF-9795-AC6A5A00886B", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "D68363A9-D1D5-4E49-98D1-E5F8C324BC22", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "A35D0B0C-695D-4274-8B9E-69ED20B62585", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "FE9C9981-BA54-48BB-A89D-3CA06C7E17C6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "EA400339-123F-494A-8CD8-7232281E7D29", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "C8E943A5-E35C-4CFA-8998-A74385C8740B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "F4D7038E-C705-4FB9-A2D3-82FFC8EE80CC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8E4F0084-91A5-4D7E-971B-9DB979849594", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "36EEF9EB-91EF-4697-A963-7C8F955778EC", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "AA0728BD-F463-456C-A6EB-9FF2FD42AA23", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "7BB0B884-C99A-4854-992F-8588840CC296", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "04BA4916-5693-4915-B4D7-29D97FA02474", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "DC588CE7-1F9D-43EF-A478-C23C8D909685", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "2DE08529-E210-48C1-A7C3-D2D316902A40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "06364800-4C54-4BE4-B4AA-0CF29E4E82AA", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "4FBDFA7B-504A-4F58-967F-15CAFCEB5594", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "4D184A8F-963A-4730-AED4-1994EEA91702", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "16DAC92E-141C-4923-96F5-2620F60E763A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "B3300D8B-E0A1-4CEF-8BE0-AED3F19E9015", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "8104E528-ED7D-451E-8834-057295A7FF49", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "0AF02DF4-7190-4F6C-8F15-37581FFC9B86", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (Todas las versiones anteriores a V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (Todas las versiones anteriores a V16 Update 4), SINAMICS GH150 (Todas las versiones), SINAMICS GL150 (con opci\u00f3n X30) (Todas las versiones), SINAMICS GM150 (con opci\u00f3n X30) (Todas las versiones), SINAMICS SH150 (Todas las versiones), SINAMICS SL150 (Todas las versiones), SINAMICS SM120 (Todas las versiones), SINAMICS SM150 (Todas las versiones), SINAMICS SM150i (Todas las versiones). SmartVNC presenta una vulnerabilidad de fuga de asignaci\u00f3n de la pila en el manejador de dise\u00f1o del dispositivo en el lado del cliente, lo que podr\u00eda resultar en una condici\u00f3n de Denegaci\u00f3n de Servicio" } ], "id": "CVE-2021-27386", "lastModified": "2024-11-21T05:57:53.533", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-05-12T14:15:11.767", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-401" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-401" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2020-07-14 14:15
Modified
2024-11-21 05:37
Severity ?
Summary
A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC HMI KTP700F Mobile Arctic (All versions), SIMATIC HMI Mobile Panels 2nd Generation (All versions), SIMATIC WinCC Runtime Advanced (All versions). Unencrypted communication between the configuration software and the respective device could allow an attacker to capture potential plain text communication and have access to sensitive information.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-364335.pdf | Vendor Advisory | |
productcert@siemens.com | https://us-cert.cisa.gov/ics/advisories/icsa-20-196-04 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-364335.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-20-196-04 | Third Party Advisory, US Government Resource |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_hmi_basic_panels_1st_generation:*:*:*:*:*:*:*:*", "matchCriteriaId": "CF9AA1D8-BDF6-40EC-8D04-49C5EAB39431", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_hmi_basic_panels_2nd_generation:*:*:*:*:*:*:*:*", "matchCriteriaId": "7E561873-49B4-4D85-8D40-9D33CEE7E7CE", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "79EE15DC-74D3-4551-AAD0-EA0CB600DA76", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3C98A381-02D5-460E-8849-63F4576BC52C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BCFE761-35C9-43EF-85BC-E8083B9F75CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp700f_mobile_arctic_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BAC6E895-5577-4047-B7CC-95398563984D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp700f_mobile_arctic:-:*:*:*:*:*:*:*", "matchCriteriaId": "4631C615-B2A4-40C3-9D1A-A1AD3C64EC51", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_mobile_panels_2nd_generation_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "08693615-7A47-4062-A73D-7CDE359826F5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_mobile_panels_2nd_generation:-:*:*:*:*:*:*:*", "matchCriteriaId": "59D5490F-EACA-467F-89ED-988A45393EAC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC HMI KTP700F Mobile Arctic (All versions), SIMATIC HMI Mobile Panels 2nd Generation (All versions), SIMATIC WinCC Runtime Advanced (All versions). Unencrypted communication between the configuration software and the respective device could allow an attacker to capture potential plain text communication and have access to sensitive information." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC HMI Basic Panels 1st Generation (incluyendo las variantes SIPLUS) (Todas las versiones), SIMATIC HMI Basic Panels 2nd Generation (incluyendo las variantes SIPLUS) (Todas las versiones), SIMATIC HMI Comfort Panels (incluyendo las variantes SIPLUS) (Todas las versiones), SIMATIC HMI KTP700F Mobile Arctic (Todas las versiones), SIMATIC HMI Mobile Panels 2nd Generation (Todas las versiones), SIMATIC WinCC Runtime Advanced (Todas las versiones). Una comunicaci\u00f3n no cifrada entre el software de configuraci\u00f3n y el dispositivo respectivo podr\u00eda permitir a un atacante capturar la comunicaci\u00f3n potencial de texto plano y tener acceso a informaci\u00f3n confidencial" } ], "id": "CVE-2020-7592", "lastModified": "2024-11-21T05:37:26.090", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-07-14T14:15:19.073", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-364335.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-196-04" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-364335.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-196-04" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-319" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-319" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-05-12 14:15
Modified
2024-11-21 05:55
Severity ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the server side when sending data from the client, which could result in a Denial-of-Service condition.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Patch, Vendor Advisory |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "244D9B27-649C-4983-B374-6A8774771AC5", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "A2530BB3-484C-4D24-82F6-15967C8B7B32", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "B5A1FACE-E693-4FDA-944D-0B7F500007B6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D7FB4AA4-1F48-4A25-AA21-5F867A38D23E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "6A673BD0-96B5-48CA-B060-A5D01687A764", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "428B633D-55FF-4DB8-B6DD-5E4EEE52A44C", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:*:*:*:*:*:*:*", "matchCriteriaId": "C33A64DD-22A2-4260-929F-7595CD037823", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "9756D206-E295-4B0C-B159-F9A953342E37", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "82D6FBBF-FD9B-4AFA-B3E1-8E3341948A37", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D43D2191-DBBD-4F7A-B02A-3DCEE46BF904", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "23C6AD3C-C15B-4B67-88D1-236C10BB12CF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FEE4201E-E660-4B3E-91EC-B6A7DC35C189", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "F2D6D924-858A-4542-BCD0-A5631F941039", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "309E4D56-6D39-4E8F-8312-FF178B721392", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "EDB63639-3101-4F60-8193-EF219D99C128", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "4C6C83EE-3DC7-4CB3-8148-CB24A825274E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C6C72B0-17D7-491E-816A-AF855166A90B", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "322584EF-72C0-4032-A02B-FDFFDCCE3FDE", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "C3D5F1BA-2BEA-40A9-8D5B-A612D467C40C", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D14DE5C7-318A-4D08-BB39-1E43F624816A", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "FCDAF23F-9272-4DC5-8D46-37FAC08950CC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "21FB0305-DF87-42FF-BACA-E8255EA74AA9", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "BAA5B299-A45A-4918-AB8F-03A476CEDA17", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "0C29FD64-C041-4269-BC52-8F91321BC247", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "7182C6C0-7DAD-4446-B14E-8EF46FB0CFA9", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "44F6F972-26AF-4A6E-AAD9-B30EBDF52465", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E57B8F3D-5E02-4F0F-9927-9D7C336EBE56", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "845C78A9-AE0F-42B9-9E25-47F541DF5196", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "B23096F5-3546-41D8-BE30-8698BC0C9B42", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D7C5AF13-69FF-444F-B84A-130D7413B307", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "66A17FC6-B6AE-4915-8069-68B41F3C87E2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4C618736-1382-4515-A295-6EC67A2731EA", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "BC0AD5A8-768E-4747-AD89-B924D369565E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "4C2FD1E4-4A01-4BFB-9D2A-5A030C37BD96", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "0AA5C3DC-E67F-4773-B32C-6B362C94BCBE", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "C96C7676-9A0D-46B5-9C49-5F5CE873E2C1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AF42C3EA-84A5-4419-ACBA-6A2F8DB994E2", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "105CCE4B-D8F9-43EA-9089-CEE16A410751", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "7C163E7E-C9E3-4FBD-885A-C2E7FB8B845F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "2CD3DD84-BDAC-4583-BD61-799A5F01A5B4", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "0A4F6758-0B36-4546-A7A7-A4C71B63772E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "12A613F7-4EA4-40FF-931F-EF3C477300DA", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "4B048552-A26D-419E-9EEA-9AFD9457B70B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "0E4E1016-F217-4B75-83D7-F73B1C5A54F9", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "EF2F6982-2C38-4F9B-87A4-AE4404197B7A", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "7745AA84-BC12-4DBD-90A6-DA294EADB7BF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0891D85-C5F4-4CD2-8EFA-84356CE36654", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:-:*:*:*:*:*:*", "matchCriteriaId": "E0005A53-33AD-47AF-B172-CAF423DE213F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update1:*:*:*:*:*:*", "matchCriteriaId": "9696B0D9-5A66-4747-9437-791EAC150DDA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update2:*:*:*:*:*:*", "matchCriteriaId": "F6AC2BA5-1668-4B71-8812-925AC6554F5A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update3:*:*:*:*:*:*", "matchCriteriaId": "047D0868-3DA6-41CF-A6F9-D15668D536FB", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "67CFFD89-1FF2-4F25-A5AB-D6FF8F721132", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "BA4B198A-8288-459D-9586-CD402DE23023", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "AC4FDB83-702A-41D5-B2A5-BDA58B7E13D2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "D972823A-1128-4222-8910-9CA3D38B472F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "A05007D7-3C49-4192-ABDF-FE94BA7FD1D1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "869AD837-79B1-4F76-947B-7DCAD172BDC0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "5C152EB8-A13A-4F16-994A-B6D93A017CC3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "42F38FBA-7D23-4CB2-9A2D-45616E2A2DFB", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "553C9A57-A9D2-47F9-ABA8-042B05DE46C7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "8F5F3B33-2A82-4CDF-A678-76DE13F256D7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "9FE49F2D-B904-4E48-AAFD-669141B570F6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "729F784C-9AC0-4231-A75A-1FA8373FA31F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "FA61AC05-061D-4EE7-BFEF-568F30B9B883", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "374BAF2F-0A32-4F1A-B838-894F9E9D3E0F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C636FCD-78AE-4FA2-95E5-2BBD5A88DA68", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "FDE42199-9152-41A3-BE56-E6789315CF28", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "040F990F-F3C2-46EF-9E40-FD136A19575F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "748BFFBC-56BD-42EC-9B5F-0752D2A70D17", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "B37490B0-A214-4A62-9B67-934048921C1E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "3D7B9F45-5749-4F36-961D-6C5D650ADA07", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "F544593D-368B-4EC1-8448-8C2BA1301216", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A9D26D9F-7081-42B2-8AE4-D04E8429B88D", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "5F902732-9944-4821-BCFB-9937D1301FF6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "B0C061AC-3E64-4667-A0E7-DD58B2E5A014", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "3EECF743-25E8-4483-AA68-B304B38A9290", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "2F557157-AAD6-4601-84C2-2F8574F23683", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "A6BF6644-AF29-4541-9D6A-D07D0CC026F0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "C4FD5396-8094-4DD0-BE7B-0FB6CC6D45F1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A8EC6926-258F-4F5C-88D2-33FE363340DB", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "97E283EF-A950-40E7-91C7-839203A333A5", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "B5B130C2-28B8-464C-981C-B5662B4B4309", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "79407355-4181-4082-A661-C27734D95363", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "8989C7D4-5246-443E-B6E4-8E91462B2E96", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "2BFBC5B2-B00B-4FCD-86B1-A187122035AB", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "B47671A7-A8DB-4DA2-9076-78708C7F1C42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D9CF819-E06C-4EAA-85B3-AC40E039D485", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "4AF727E5-7849-4980-8AA5-7469FD52DF86", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "F36ABC58-C9FE-4F4A-AB81-26D48A79FFD2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "A87DD9FF-9CA3-4AE2-8C86-C30A779E0CE6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "891AF48F-1F4D-4AB8-AE66-FBABDD2CAA76", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "5052CB07-626A-46C4-8966-B8C9325A3BB3", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "6CD47CC7-1414-42C9-94C6-9DBC2C1D9CBE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B28FB484-526A-437E-80E3-B62F54F1BEF6", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "61DFC57F-0359-4B4A-A13C-067B21D3DA7B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "81CE70BF-EBBE-4CD7-999C-25662670EFCB", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "034B7CFC-1234-4914-8C84-7E5BD5FB6E4D", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "221EB3AE-1420-46F8-9EAD-1914503B0435", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "5F9A416C-277F-44B0-A74C-263CB0C37D03", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "FA858127-69A0-4280-80A8-65E0778A90AD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "66FC2264-7DDD-4BEF-9795-AC6A5A00886B", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "D68363A9-D1D5-4E49-98D1-E5F8C324BC22", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "A35D0B0C-695D-4274-8B9E-69ED20B62585", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "FE9C9981-BA54-48BB-A89D-3CA06C7E17C6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "EA400339-123F-494A-8CD8-7232281E7D29", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "C8E943A5-E35C-4CFA-8998-A74385C8740B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "F4D7038E-C705-4FB9-A2D3-82FFC8EE80CC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8E4F0084-91A5-4D7E-971B-9DB979849594", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "36EEF9EB-91EF-4697-A963-7C8F955778EC", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "AA0728BD-F463-456C-A6EB-9FF2FD42AA23", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "7BB0B884-C99A-4854-992F-8588840CC296", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "04BA4916-5693-4915-B4D7-29D97FA02474", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "DC588CE7-1F9D-43EF-A478-C23C8D909685", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "2DE08529-E210-48C1-A7C3-D2D316902A40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "06364800-4C54-4BE4-B4AA-0CF29E4E82AA", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "4FBDFA7B-504A-4F58-967F-15CAFCEB5594", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "4D184A8F-963A-4730-AED4-1994EEA91702", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "16DAC92E-141C-4923-96F5-2620F60E763A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "B3300D8B-E0A1-4CEF-8BE0-AED3F19E9015", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "8104E528-ED7D-451E-8834-057295A7FF49", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "0AF02DF4-7190-4F6C-8F15-37581FFC9B86", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the server side when sending data from the client, which could result in a Denial-of-Service condition." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Outdoor Panels V15 7\\\" y 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (Todas las versiones anteriores a V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (Todas las versiones anteriores a V16 Update 4). SmartVNC presenta una vulnerabilidad de acceso a la memoria fuera de l\u00edmites que podr\u00eda ser desencadenada en el lado del servidor al enviar datos desde el cliente, lo que podr\u00eda resultar en una condici\u00f3n de Denegaci\u00f3n de Servicio" } ], "id": "CVE-2021-25660", "lastModified": "2024-11-21T05:55:14.307", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-05-12T14:15:11.253", "references": [ { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-788" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2019-04-17 14:29
Modified
2024-11-21 04:46
Severity ?
Summary
A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R family (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions < V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp443-1_opc_ua_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5D0780D2-8892-490E-9C38-6D1516EBCA76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp443-1_opc_ua:-:*:*:*:*:*:*:*", "matchCriteriaId": "47272AD2-1D05-419E-A6BE-8836DF69FF82", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200_open_controller_cpu_1515sp_pc2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DFB5AE88-04E5-467E-85E5-D3C0DDA2B21F", "versionEndExcluding": "2.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200_open_controller_cpu_1515sp_pc2:-:*:*:*:*:*:*:*", "matchCriteriaId": "AF0944C4-8FD7-4B00-85B7-6DB430EAA884", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc_diagmonitor_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "91371CD0-EBDF-43C5-A262-A46E1C343716", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc_diagmonitor:-:*:*:*:*:*:*:*", "matchCriteriaId": "A5E06833-4C26-40AC-B6CF-F7D1322462D6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_net_pc_software_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "77022802-113F-42E7-8FBF-C47BB50E8DA7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_net_pc_software:-:*:*:*:*:*:*:*", "matchCriteriaId": "E7A00F5A-9B28-45FF-8549-290302939DFD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf188c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7F3D41E9-58B3-4251-8710-A8C4A24ABBD3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf188c:-:*:*:*:*:*:*:*", "matchCriteriaId": "E21F9909-8D80-40BE-81E0-6ED7FE140A3A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf600r_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9523EC09-36C9-41E1-A485-C75819A2DB72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf600r:-:*:*:*:*:*:*:*", "matchCriteriaId": "EFA55275-691D-4269-93E4-C559C89E3FA3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "065D2218-EA10-410E-A49A-C9A259469421", "versionEndIncluding": "2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500:-:*:*:*:*:*:*:*", "matchCriteriaId": "30DDEA9B-E1BF-4572-8E12-D13C54603E77", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:opc_unified_architecture:*:*:*:*:*:*:*:*", "matchCriteriaId": "6230C5B0-2F36-4C94-BA28-D36170952423", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:*", "matchCriteriaId": "054D17CD-74AF-473E-A3BC-7B69DFB1C04B", "versionEndIncluding": "2.5", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_oa:*:*:*:*:*:*:*:*", "matchCriteriaId": "1B74D88E-E8D7-4AA9-8B54-CC833E26CEB4", "versionEndExcluding": "3.15-p018", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "79EE15DC-74D3-4551-AAD0-EA0CB600DA76", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_comfort:*:*:*:*:*:*:*:*", "matchCriteriaId": "C9AE946B-D532-4CEB-B109-C8B951B61E49", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_hsp_comfort:*:*:*:*:*:*:*:*", "matchCriteriaId": "49D722B2-948B-4F11-AD36-E1378BB40403", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_mobile:*:*:*:*:*:*:*:*", "matchCriteriaId": "455411C4-037C-47BF-9BD6-AC7F9C2D30F1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinec-nms:*:*:*:*:*:*:*:*", "matchCriteriaId": "8ED63145-9082-4346-871B-DF0A6F91E7F0", "versionEndExcluding": "1.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinec-nms:1.0:-:*:*:*:*:*:*", "matchCriteriaId": "1F6F05DC-0FBA-4D25-A2E6-06D873B3DFAA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinema_server:*:*:*:*:*:*:*:*", "matchCriteriaId": "C55DA617-6333-40DA-AB7D-EE49A453E143", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinumerik_opc_ua_server:*:*:*:*:*:*:*:*", "matchCriteriaId": "5E31B88B-E743-4DFD-996B-154F7F48C510", "versionEndExcluding": "2.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*", "matchCriteriaId": "D2ECBEF2-9B1A-49F8-9850-0AF09BF71ED7", "versionEndExcluding": "3.1.1", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "58CCDA0F-F657-4AF8-BE53-A3993C0280B3", "versionEndIncluding": "2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500f:-:*:*:*:*:*:*:*", "matchCriteriaId": "A255BC06-2776-4111-A525-76B17371B295", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F3F162D0-998E-4EC9-BA59-D9B47B07EF69", "versionEndIncluding": "2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500s:-:*:*:*:*:*:*:*", "matchCriteriaId": "C1752A2A-0034-4E00-AAC6-FA15345D7A41", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500t_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C47ADAD6-2DDE-49EF-864B-CC9448399E7B", "versionEndIncluding": "2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500t:-:*:*:*:*:*:*:*", "matchCriteriaId": "741B2C38-174C-49DF-98D8-F7D6F49D1CE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7299F88D-8885-4871-93E1-CBEFD3156B15", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "F18EA7BD-47D0-4367-8F18-C89239B201E3", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:15.1:upd_1:*:*:*:*:*:*", "matchCriteriaId": "DE71784C-012F-40EC-82E2-3BE8589F00DC", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:15.1:upd_2:*:*:*:*:*:*", "matchCriteriaId": "C5A35FDE-C76F-430E-BD15-373F9F30FED5", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:15.1:upd_3:*:*:*:*:*:*", "matchCriteriaId": "37A6344F-CB58-4CFA-A971-395BFB3FF02B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*", "matchCriteriaId": "F4830E0D-0128-4E5B-AB81-2B238471AE4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A8EC6926-258F-4F5C-88D2-33FE363340DB", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "97E283EF-A950-40E7-91C7-839203A333A5", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:upd_1:*:*:*:*:*:*", "matchCriteriaId": "E949961E-320A-4E25-A0CA-5EBC7DA0AD9D", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:upd_2:*:*:*:*:*:*", "matchCriteriaId": "A390DCB7-4511-4931-A34B-BF6A9B84370D", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:upd_3:*:*:*:*:*:*", "matchCriteriaId": "FF5136A8-130C-4121-A250-B4DE5883239E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "66FC2264-7DDD-4BEF-9795-AC6A5A00886B", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "D68363A9-D1D5-4E49-98D1-E5F8C324BC22", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:upd_1:*:*:*:*:*:*", "matchCriteriaId": "862B1996-202B-42DF-A7DA-D01CD43C4AB3", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:upd_2:*:*:*:*:*:*", "matchCriteriaId": "7AFD3E4C-7125-4FB5-991F-76A31AD61BD9", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:upd_3:*:*:*:*:*:*", "matchCriteriaId": "71172F82-C9B6-4DEC-ADCC-F455E72936CA", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B28FB484-526A-437E-80E3-B62F54F1BEF6", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "61DFC57F-0359-4B4A-A13C-067B21D3DA7B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:upd_1:*:*:*:*:*:*", "matchCriteriaId": "A8CA985F-3678-46F4-BE2E-BDBCCD1BC0FE", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:upd_2:*:*:*:*:*:*", "matchCriteriaId": "1A28CC05-0CEA-4221-83CE-4029726F60E0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:upd_3:*:*:*:*:*:*", "matchCriteriaId": "5D612CB7-45A0-44AC-BB96-12AFE2B14CE8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D9CF819-E06C-4EAA-85B3-AC40E039D485", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "4AF727E5-7849-4980-8AA5-7469FD52DF86", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:upd_1:*:*:*:*:*:*", "matchCriteriaId": "7B0FAB4F-7D95-4FC0-AF59-CCEDC6E22DC3", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:upd_2:*:*:*:*:*:*", "matchCriteriaId": "5C925AE3-7262-4DDD-803D-D871A66CD2B2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:upd_3:*:*:*:*:*:*", "matchCriteriaId": "E64DEED6-7E6F-4E79-BA4D-2B2E43B2B97D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8E4F0084-91A5-4D7E-971B-9DB979849594", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "36EEF9EB-91EF-4697-A963-7C8F955778EC", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:upd_1:*:*:*:*:*:*", "matchCriteriaId": "9429BA23-CB76-4574-B7F8-530882CF704A", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:upd_2:*:*:*:*:*:*", "matchCriteriaId": "3794C871-098D-428F-89EA-ADDEFD4E4A86", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:upd_3:*:*:*:*:*:*", "matchCriteriaId": "386F501D-5C7D-4336-A39D-31B12C5BCB56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V2.7), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants) (All versions \u003c V15.1 Upd 4), SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants) (All versions \u003c V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions \u003c V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions \u003c V1.1.0), SIMATIC RF600R family (All versions \u003c V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.5 \u003c V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions \u003c V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Upd 4), SINEC NMS (All versions \u003c V1.0 SP1), SINEMA Server (All versions \u003c V14 SP2), SINUMERIK OPC UA Server (All versions \u003c V2.1), TeleControl Server Basic (All versions \u003c V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC CP 443-1 OPC UA (todas las versiones), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incluidas las variantes SIPLUS) (todas las versiones anteriores a V2.7), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026amp; 15\" (incluidas las variantes SIPLUS) (todas las versiones anteriores a V15.1 Upd 4), SIMATIC HMI Comfort Panels 4\" - 22\" (incluidas las variantes SIPLUS) (todas las versiones anteriores a V15. 1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 y KTP900F (Todas las versiones anteriores a V15.1 Upd 4), SIMATIC IPC DiagMonitor (Todas las versiones anteriores a V5.1. 3), SIMATIC NET PC Software V13 (Todas las versiones), SIMATIC NET PC Software V14 (Todas las versiones anteriores a V14 SP1 Update 14), SIMATIC NET PC Software V15 (Todas las versiones), SIMATIC RF188C (Todas las versiones anteriores a V1. 1.0), familia SIMATIC RF600R (Todas las versiones anteriores a V3.2.1), familia de CPUs SIMATIC S7-1500 (incluidas las CPUs ET200 relacionadas y las variantes SIPLUS) (Todas las versiones posteriores o iguales a V2.5 anteriores a V2.6.1), SIMATIC S7-1500 Software Controller (Todas las versiones entre V2.5 (incluida) y V2.7 (excluida)), SIMATIC WinCC OA (Todas las versiones anteriores a V3. 15 P018), SIMATIC WinCC Runtime Advanced (Todas las versiones anteriores a V15.1 Upd 4), SINEC NMS (Todas las versiones anteriores a V1.0 SP1), SINEMA Server (Todas las versiones anteriores a V14 SP2), SINUMERIK OPC UA Server (Todas las versiones anteriores a V2.1), TeleControl Server Basic (Todas las versiones anteriores a V3.1.1). Los paquetes de red especialmente dise\u00f1ados que se env\u00edan a los dispositivos afectados en el puerto 4840/tcp podr\u00edan permitir a un atacante remoto no autenticado provocar una condici\u00f3n de denegaci\u00f3n de servicio de la comunicaci\u00f3n OPC o bloquear el dispositivo. La vulnerabilidad de seguridad podr\u00eda ser explotada por un atacante con acceso a la red de los sistemas afectados. La explotaci\u00f3n exitosa no requiere privilegios del sistema ni interacci\u00f3n del usuario. Un atacante podr\u00eda utilizar la vulnerabilidad para comprometer la disponibilidad de la comunicaci\u00f3n OPC" } ], "id": "CVE-2019-6575", "lastModified": "2024-11-21T04:46:43.960", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2019-04-17T14:29:03.760", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-248" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-755" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2021-05-12 14:15
Modified
2024-11-21 05:57
Severity ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | Vendor Advisory | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Vendor Advisory | |
productcert@siemens.com | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | Third Party Advisory, US Government Resource |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0891D85-C5F4-4CD2-8EFA-84356CE36654", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:-:*:*:*:*:*:*", "matchCriteriaId": "E0005A53-33AD-47AF-B172-CAF423DE213F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update1:*:*:*:*:*:*", "matchCriteriaId": "9696B0D9-5A66-4747-9437-791EAC150DDA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update2:*:*:*:*:*:*", "matchCriteriaId": "F6AC2BA5-1668-4B71-8812-925AC6554F5A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update3:*:*:*:*:*:*", "matchCriteriaId": "047D0868-3DA6-41CF-A6F9-D15668D536FB", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sh150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0F1FAFD2-1E4D-44F3-87A1-8A1380B980BC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sh150:-:*:*:*:*:*:*:*", "matchCriteriaId": "EBC7AA8D-9046-4111-A263-38343997F984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm150i_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D6067521-A21D-4B2A-AFB2-2E033F66B63E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm150i:-:*:*:*:*:*:*:*", "matchCriteriaId": "A44DEAD8-8DB8-41CC-9495-B842BE76EA8F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4BF9157D-0089-4569-9AA1-4DEE94140D25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*", "matchCriteriaId": "BF977545-395A-4C34-BB22-A1047B5B6E85", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4D780400-0AA8-449C-B754-7167CA878D3D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DED7F33B-D475-4232-8683-48554A6729F7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "61CD50EE-6C46-445E-8D46-82768CAAC305", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E032554B-7F51-4482-AF55-743FFB5AC352", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "C6619B0F-7CDC-40A6-89B2-C6067AF45214", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CFFE3048-EEB0-48A0-BED0-8647284B022B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*", "matchCriteriaId": "444DD77F-DB65-4766-A89D-7A679B4CA1E1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33B7E1DE-61B5-4CFC-8640-EB8029CD79D6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "2AE231E2-2B2B-407A-BF7A-9EA35F394229", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "244D9B27-649C-4983-B374-6A8774771AC5", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "A2530BB3-484C-4D24-82F6-15967C8B7B32", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "B5A1FACE-E693-4FDA-944D-0B7F500007B6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D7FB4AA4-1F48-4A25-AA21-5F867A38D23E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "6A673BD0-96B5-48CA-B060-A5D01687A764", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "428B633D-55FF-4DB8-B6DD-5E4EEE52A44C", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:*:*:*:*:*:*:*", "matchCriteriaId": "C33A64DD-22A2-4260-929F-7595CD037823", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "9756D206-E295-4B0C-B159-F9A953342E37", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "82D6FBBF-FD9B-4AFA-B3E1-8E3341948A37", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D43D2191-DBBD-4F7A-B02A-3DCEE46BF904", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "23C6AD3C-C15B-4B67-88D1-236C10BB12CF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FEE4201E-E660-4B3E-91EC-B6A7DC35C189", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "F2D6D924-858A-4542-BCD0-A5631F941039", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "309E4D56-6D39-4E8F-8312-FF178B721392", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "EDB63639-3101-4F60-8193-EF219D99C128", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "4C6C83EE-3DC7-4CB3-8148-CB24A825274E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C6C72B0-17D7-491E-816A-AF855166A90B", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "322584EF-72C0-4032-A02B-FDFFDCCE3FDE", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "C3D5F1BA-2BEA-40A9-8D5B-A612D467C40C", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D14DE5C7-318A-4D08-BB39-1E43F624816A", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "FCDAF23F-9272-4DC5-8D46-37FAC08950CC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "21FB0305-DF87-42FF-BACA-E8255EA74AA9", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "BAA5B299-A45A-4918-AB8F-03A476CEDA17", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "0C29FD64-C041-4269-BC52-8F91321BC247", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "7182C6C0-7DAD-4446-B14E-8EF46FB0CFA9", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "44F6F972-26AF-4A6E-AAD9-B30EBDF52465", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E57B8F3D-5E02-4F0F-9927-9D7C336EBE56", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "845C78A9-AE0F-42B9-9E25-47F541DF5196", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "B23096F5-3546-41D8-BE30-8698BC0C9B42", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D7C5AF13-69FF-444F-B84A-130D7413B307", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "66A17FC6-B6AE-4915-8069-68B41F3C87E2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4C618736-1382-4515-A295-6EC67A2731EA", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "BC0AD5A8-768E-4747-AD89-B924D369565E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "4C2FD1E4-4A01-4BFB-9D2A-5A030C37BD96", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "0AA5C3DC-E67F-4773-B32C-6B362C94BCBE", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "C96C7676-9A0D-46B5-9C49-5F5CE873E2C1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AF42C3EA-84A5-4419-ACBA-6A2F8DB994E2", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "105CCE4B-D8F9-43EA-9089-CEE16A410751", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "7C163E7E-C9E3-4FBD-885A-C2E7FB8B845F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "2CD3DD84-BDAC-4583-BD61-799A5F01A5B4", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "0A4F6758-0B36-4546-A7A7-A4C71B63772E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "12A613F7-4EA4-40FF-931F-EF3C477300DA", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "4B048552-A26D-419E-9EEA-9AFD9457B70B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "0E4E1016-F217-4B75-83D7-F73B1C5A54F9", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "EF2F6982-2C38-4F9B-87A4-AE4404197B7A", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "7745AA84-BC12-4DBD-90A6-DA294EADB7BF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "67CFFD89-1FF2-4F25-A5AB-D6FF8F721132", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "BA4B198A-8288-459D-9586-CD402DE23023", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "AC4FDB83-702A-41D5-B2A5-BDA58B7E13D2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "D972823A-1128-4222-8910-9CA3D38B472F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "A05007D7-3C49-4192-ABDF-FE94BA7FD1D1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "869AD837-79B1-4F76-947B-7DCAD172BDC0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "5C152EB8-A13A-4F16-994A-B6D93A017CC3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "42F38FBA-7D23-4CB2-9A2D-45616E2A2DFB", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "553C9A57-A9D2-47F9-ABA8-042B05DE46C7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "8F5F3B33-2A82-4CDF-A678-76DE13F256D7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "9FE49F2D-B904-4E48-AAFD-669141B570F6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "729F784C-9AC0-4231-A75A-1FA8373FA31F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "FA61AC05-061D-4EE7-BFEF-568F30B9B883", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "374BAF2F-0A32-4F1A-B838-894F9E9D3E0F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C636FCD-78AE-4FA2-95E5-2BBD5A88DA68", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "FDE42199-9152-41A3-BE56-E6789315CF28", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "040F990F-F3C2-46EF-9E40-FD136A19575F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "748BFFBC-56BD-42EC-9B5F-0752D2A70D17", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "B37490B0-A214-4A62-9B67-934048921C1E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "3D7B9F45-5749-4F36-961D-6C5D650ADA07", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "F544593D-368B-4EC1-8448-8C2BA1301216", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A9D26D9F-7081-42B2-8AE4-D04E8429B88D", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "5F902732-9944-4821-BCFB-9937D1301FF6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "B0C061AC-3E64-4667-A0E7-DD58B2E5A014", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "3EECF743-25E8-4483-AA68-B304B38A9290", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "2F557157-AAD6-4601-84C2-2F8574F23683", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "A6BF6644-AF29-4541-9D6A-D07D0CC026F0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "C4FD5396-8094-4DD0-BE7B-0FB6CC6D45F1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A8EC6926-258F-4F5C-88D2-33FE363340DB", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "97E283EF-A950-40E7-91C7-839203A333A5", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "B5B130C2-28B8-464C-981C-B5662B4B4309", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "79407355-4181-4082-A661-C27734D95363", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "8989C7D4-5246-443E-B6E4-8E91462B2E96", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "2BFBC5B2-B00B-4FCD-86B1-A187122035AB", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "B47671A7-A8DB-4DA2-9076-78708C7F1C42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D9CF819-E06C-4EAA-85B3-AC40E039D485", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "4AF727E5-7849-4980-8AA5-7469FD52DF86", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "F36ABC58-C9FE-4F4A-AB81-26D48A79FFD2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "A87DD9FF-9CA3-4AE2-8C86-C30A779E0CE6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "891AF48F-1F4D-4AB8-AE66-FBABDD2CAA76", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "5052CB07-626A-46C4-8966-B8C9325A3BB3", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "6CD47CC7-1414-42C9-94C6-9DBC2C1D9CBE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B28FB484-526A-437E-80E3-B62F54F1BEF6", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "61DFC57F-0359-4B4A-A13C-067B21D3DA7B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "81CE70BF-EBBE-4CD7-999C-25662670EFCB", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "034B7CFC-1234-4914-8C84-7E5BD5FB6E4D", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "221EB3AE-1420-46F8-9EAD-1914503B0435", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "5F9A416C-277F-44B0-A74C-263CB0C37D03", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "FA858127-69A0-4280-80A8-65E0778A90AD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "66FC2264-7DDD-4BEF-9795-AC6A5A00886B", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "D68363A9-D1D5-4E49-98D1-E5F8C324BC22", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "A35D0B0C-695D-4274-8B9E-69ED20B62585", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "FE9C9981-BA54-48BB-A89D-3CA06C7E17C6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "EA400339-123F-494A-8CD8-7232281E7D29", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "C8E943A5-E35C-4CFA-8998-A74385C8740B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "F4D7038E-C705-4FB9-A2D3-82FFC8EE80CC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8E4F0084-91A5-4D7E-971B-9DB979849594", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "36EEF9EB-91EF-4697-A963-7C8F955778EC", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "AA0728BD-F463-456C-A6EB-9FF2FD42AA23", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "7BB0B884-C99A-4854-992F-8588840CC296", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "04BA4916-5693-4915-B4D7-29D97FA02474", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "DC588CE7-1F9D-43EF-A478-C23C8D909685", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "2DE08529-E210-48C1-A7C3-D2D316902A40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "06364800-4C54-4BE4-B4AA-0CF29E4E82AA", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "4FBDFA7B-504A-4F58-967F-15CAFCEB5594", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "4D184A8F-963A-4730-AED4-1994EEA91702", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "16DAC92E-141C-4923-96F5-2620F60E763A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "B3300D8B-E0A1-4CEF-8BE0-AED3F19E9015", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "8104E528-ED7D-451E-8834-057295A7FF49", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "0AF02DF4-7190-4F6C-8F15-37581FFC9B86", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (Todas las versiones anteriores a V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (Todas las versiones anteriores a V16 Update 4), SINAMICS GH150 (Todas las versiones), SINAMICS GL150 (con opci\u00f3n X30) (Todas las versiones), SINAMICS GM150 (con opci\u00f3n X30) (Todas las versiones), SINAMICS SH150 (Todas las versiones), SINAMICS SL150 (Todas las versiones), SINAMICS SM120 (Todas las versiones), SINAMICS SM150 (Todas las versiones), SINAMICS SM150i (Todas las versiones). Un atacante remoto podr\u00eda enviar paquetes especialmente dise\u00f1ados al manejador de dise\u00f1o de dispositivos SmartVNC en el lado del cliente, lo que podr\u00eda influir en la cantidad de recursos consumidos y dar lugar a una condici\u00f3n de denegaci\u00f3n de servicio (bucle infinito)" } ], "id": "CVE-2021-27385", "lastModified": "2024-11-21T05:57:53.380", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-05-12T14:15:11.727", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-835" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2019-04-17 14:29
Modified
2024-11-21 04:46
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
The webserver of the affected devices contains a vulnerability that may lead to
a denial of service condition. An attacker may cause a denial of service
situation which leads to a restart of the webserver of the affected device.
The security vulnerability could be exploited by an attacker with network
access to the affected systems. Successful exploitation requires no system
privileges and no user interaction. An attacker could use the vulnerability
to compromise availability of the device.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:cp1604_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E737620D-9D00-4151-B232-7DFB7FD768B3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:cp1604:-:*:*:*:*:*:*:*", "matchCriteriaId": "6222006F-09D7-49F7-B8C7-4D94298A8F6A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:cp1616_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "65FE6F54-1457-4EB6-9273-1D93B3B97386", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:cp1616:-:*:*:*:*:*:*:*", "matchCriteriaId": "184365A2-BAD2-4926-ACEE-F71E018D3CE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf185c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "69EE2BF6-3846-478F-9AC6-BEF34617F3B5", "versionEndExcluding": "1.1.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf185c:-:*:*:*:*:*:*:*", "matchCriteriaId": "82494B5E-80EE-47ED-B87E-CF8C8907B6FE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp343-1_advanced_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1E6601B8-E032-4B39-BF65-F25CF047EB99", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp343-1_advanced:-:*:*:*:*:*:*:*", "matchCriteriaId": "ACCC0229-E454-4BEF-931A-3CD820500822", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp443-1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2035A020-F41E-4FC7-A290-9923574D4921", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp443-1:-:*:*:*:*:*:*:*", "matchCriteriaId": "EB8636E9-A3DA-4DDC-A3FC-B3EAAD07952E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp443-1_advanced_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1AD15638-8B84-4DA2-9DDC-9A1CA3548E91", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp443-1_advanced:-:*:*:*:*:*:*:*", "matchCriteriaId": "BFE94F56-71DB-4837-9818-6827C80DE2BC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D1873751-81F4-4732-B30F-9F2DEECBC110", "versionEndExcluding": "2.1.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9A5678E-9EAA-441A-AC77-94F824D64AEE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F36AC571-C958-4CB8-91D9-5417C1812C02", "versionEndExcluding": "2.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc2:-:*:*:*:*:*:*:*", "matchCriteriaId": "00361A3C-60E9-4365-BB51-09D7792C441D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7299F88D-8885-4871-93E1-CBEFD3156B15", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "F18EA7BD-47D0-4367-8F18-C89239B201E3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*", "matchCriteriaId": "F4830E0D-0128-4E5B-AB81-2B238471AE4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "865FD012-F390-4BB8-B14F-533840B95512", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "5418D916-49A6-4B79-A653-E2C5221DEBE8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BCFE761-35C9-43EF-85BC-E8083B9F75CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A8EC6926-258F-4F5C-88D2-33FE363340DB", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "97E283EF-A950-40E7-91C7-839203A333A5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D9CF819-E06C-4EAA-85B3-AC40E039D485", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "4AF727E5-7849-4980-8AA5-7469FD52DF86", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B28FB484-526A-437E-80E3-B62F54F1BEF6", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "61DFC57F-0359-4B4A-A13C-067B21D3DA7B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "66FC2264-7DDD-4BEF-9795-AC6A5A00886B", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "D68363A9-D1D5-4E49-98D1-E5F8C324BC22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8E4F0084-91A5-4D7E-971B-9DB979849594", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "36EEF9EB-91EF-4697-A963-7C8F955778EC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_cp443-1_opc_ua:*:*:*:*:*:*:*:*", "matchCriteriaId": "56396833-12BF-4AE5-8D3E-695652A99DBF", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_ipc_diagmonitor:*:*:*:*:*:*:*:*", "matchCriteriaId": "6FD49A39-47D7-473C-9E46-6D9246BC6D04", "versionEndExcluding": "5.1.3", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:*", "matchCriteriaId": "11C0A94D-5506-4A75-99E1-CA9769AF057C", "versionEndExcluding": "2.7", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_s7-plcsim_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "8B66A2A4-5062-45F8-A615-2DA716650909", "versionEndExcluding": "2.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_s7-plcsim_advanced:2.0:-:*:*:*:*:*:*", "matchCriteriaId": "AED3A3AF-EF77-4E58-91AD-BBE01E1DA4A6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_s7-plcsim_advanced:2.0:sp1:*:*:*:*:*:*", "matchCriteriaId": "23039930-E45C-4B0E-883A-E2F9A7502984", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "06364800-4C54-4BE4-B4AA-0CF29E4E82AA", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "4FBDFA7B-504A-4F58-967F-15CAFCEB5594", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "4D184A8F-963A-4730-AED4-1994EEA91702", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "16DAC92E-141C-4923-96F5-2620F60E763A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "B3300D8B-E0A1-4CEF-8BE0-AED3F19E9015", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sitop_manager:*:*:*:*:*:*:*:*", "matchCriteriaId": "2662688E-6975-46C7-939B-25FF4790518D", "versionEndExcluding": "1.1", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf600r_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "16CBED3D-892A-4EC0-BE2E-358040C34304", "versionEndExcluding": "3.2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf600r:-:*:*:*:*:*:*:*", "matchCriteriaId": "EFA55275-691D-4269-93E4-C559C89E3FA3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf188c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "25F96DAA-696D-4EB4-97DF-986C7681700B", "versionEndExcluding": "1.1.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf188c:-:*:*:*:*:*:*:*", "matchCriteriaId": "E21F9909-8D80-40BE-81E0-6ED7FE140A3A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf186c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CF8FFD1C-8E33-48E9-A884-B80311F8BA4C", "versionEndExcluding": "1.1.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf186c:-:*:*:*:*:*:*:*", "matchCriteriaId": "9B0933EB-82BE-42BB-978B-C9EC2FE1C795", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf182c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0FC4F972-3A3B-421C-8D62-9C5C4D1992CF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf182c:-:*:*:*:*:*:*:*", "matchCriteriaId": "7540DAD9-2AAC-46A9-B1C5-BB1AC4FCE710", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf181-eip_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AFA94867-4367-4186-8A4B-44C3CBCCEF7F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf181-eip:-:*:*:*:*:*:*:*", "matchCriteriaId": "E10A0D57-8805-44DB-95E3-1B240ED5ED09", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2AE766CD-695B-4A12-8BC5-3743D8E3D73E", "versionEndExcluding": "2.6.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500:-:*:*:*:*:*:*:*", "matchCriteriaId": "30DDEA9B-E1BF-4572-8E12-D13C54603E77", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9461CADE-1624-4D1B-8CF2-CF65F75071C0", "versionEndExcluding": "3.3.17", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD4E99-5C66-443F-8B6F-FA01C895DE78", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-400_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0A2219FE-2C3F-4948-85D6-3C53AC08722B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "795D0FF9-1D0B-4C74-BEF3-58EAE74DFA0C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-400_pn\\/dp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BC917346-94F6-44FD-AC00-AED0CF3CBBD1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_pn\\/dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "F60D816D-85A5-4971-AF2D-666AE0B74E9E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_advanced_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C8E76BDE-C7E9-4D6B-B5D9-A456516CD016", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_advanced:-:*:*:*:*:*:*:*", "matchCriteriaId": "71DA3D1A-E435-418F-9A13-945B4BA15FC7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_basic_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "80D166A8-1EEC-42F4-8EAB-1747247A7A05", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_basic:-:*:*:*:*:*:*:*", "matchCriteriaId": "FFA520B6-5177-43E4-87C0-C215F79FE9B4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_standard_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5C887573-8BE8-42CF-B35A-22F9311AC627", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_standard:-:*:*:*:*:*:*:*", "matchCriteriaId": "3A5A3F7E-D039-430F-89B0-6AB4FD2428D4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "80BDBB38-20D2-48C3-8B58-62C2D8CC00B8", "versionEndExcluding": "2010", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:2010:-:*:*:*:*:*:*", "matchCriteriaId": "EA59D713-F342-4CDA-BDC8-108352D385DA", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_winac_rtx:-:*:*:*:*:*:*:*", "matchCriteriaId": "CA5ADAB0-3985-4933-8CDD-D1546D8271CC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simocode_pro_v_eip_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8A001968-C7FD-4C11-8439-11532B234CC2", "versionEndExcluding": "1.1.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simocode_pro_v_eip:-:*:*:*:*:*:*:*", "matchCriteriaId": "50BDA360-0D33-42DC-ADB9-2F69503C2CD8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simocode_pro_v_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "15CB26DA-7CA0-4BD6-A219-01F6E8A6F03F", "versionEndExcluding": "2.1.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simocode_pro_v_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "1779AE78-AC90-48BE-8FF2-CC11E7CA3CB4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_g130_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "856768D2-C096-4CA7-B26F-E94B005C0D79", "versionEndExcluding": "5.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*", "matchCriteriaId": "373DBE44-AC28-4D04-93BB-35CD8C60E899", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_g150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C579C2C7-0402-46B2-A770-C3B7F71D1096", "versionEndExcluding": "5.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*", "matchCriteriaId": "2296CA65-0E89-4BCB-8003-E7212BF1F585", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "03F9CBC3-B2B3-4FA7-963D-A8F3AE6D8EA0", "versionEndExcluding": "5.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*", "matchCriteriaId": "E5A824BD-935F-4E53-8313-C5544B0489C7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_s150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "126AC93E-A39F-4754-9707-207C9F2F64F4", "versionEndExcluding": "5.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_s150_firmware:5.1:-:*:*:*:*:*:*", "matchCriteriaId": "3E8BCCED-BDC6-4785-8705-799836E5024E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_s150_firmware:5.1:sp1:*:*:*:*:*:*", "matchCriteriaId": "098262CC-4D3B-4E55-83C3-2816403C553B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_s150_firmware:5.1:sp1_hotfix2:*:*:*:*:*:*", "matchCriteriaId": "6092F899-9A89-4FA4-BD80-97511DF7CF8F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_s150:-:*:*:*:*:*:*:*", "matchCriteriaId": "0D48682C-A39D-4A09-B904-50FA64A9D2A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_s210_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B7269713-6505-41DF-B85B-F729E24A3F5B", "versionEndExcluding": "5.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_s210_firmware:5.1:-:*:*:*:*:*:*", "matchCriteriaId": "BEBF14B3-65A0-41E9-B99C-D88548F307CD", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_s210_firmware:5.1:sp1:*:*:*:*:*:*", "matchCriteriaId": "F151297C-3097-483F-98B5-0261BD547421", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_s210:-:*:*:*:*:*:*:*", "matchCriteriaId": "7BFA8FB3-12A9-4D2E-BCFD-C66313521C80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sitop_psu8600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6F389808-001E-4650-86B2-00A72D25BCD0", "versionEndExcluding": "1.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sitop_psu8600:-:*:*:*:*:*:*:*", "matchCriteriaId": "55058209-8AE5-42AF-80D4-5A7A44307266", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sitop_ups1600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BD39CC96-ABE3-4854-A102-36AFE1F6CB14", "versionEndExcluding": "2.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sitop_ups1600:-:*:*:*:*:*:*:*", "matchCriteriaId": "6FC1A64E-6A27-4F91-8A13-829E0F7D8E80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:tim_1531_irc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B023E75A-B76D-4FD8-9660-1F233092160F", "versionEndExcluding": "2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*", "matchCriteriaId": "C1D94BEB-BBFB-4258-9835-87DBBB999239", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F9C47A4A-BE81-499A-AB36-491661B88693", "versionEndExcluding": "2.6.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500f:-:*:*:*:*:*:*:*", "matchCriteriaId": "A255BC06-2776-4111-A525-76B17371B295", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "66A446D2-39ED-4635-AAA0-85D977F600FE", "versionEndExcluding": "2.6.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500s:-:*:*:*:*:*:*:*", "matchCriteriaId": "C1752A2A-0034-4E00-AAC6-FA15345D7A41", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500t_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5238622A-BCAD-4A06-9920-49BECFDDC2A6", "versionEndExcluding": "2.6.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500t:-:*:*:*:*:*:*:*", "matchCriteriaId": "741B2C38-174C-49DF-98D8-F7D6F49D1CE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6E231DE7-8B8D-41A3-A163-CE8EF50AF9D0", "versionEndExcluding": "4.8", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:4.8:-:*:*:*:*:*:*", "matchCriteriaId": "6D076504-AFE3-4C51-80E5-C5992CA7D511", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*", "matchCriteriaId": "BF977545-395A-4C34-BB22-A1047B5B6E85", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3653DA37-DB23-41E0-8CE8-838E384AA40A", "versionEndExcluding": "4.8", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:4.8:-:*:*:*:*:*:*", "matchCriteriaId": "0F86A334-10F9-4DFB-A421-CBCAFD86C8C2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DED7F33B-D475-4232-8683-48554A6729F7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0E25804D-D943-4C2A-9C78-AAC61F7BA4FF", "versionEndExcluding": "4.8", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:4.8:-:*:*:*:*:*:*", "matchCriteriaId": "06B69CD4-3AEC-4014-81DB-33805A44A5D3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FD67D30A-8681-41AE-B248-7E50BA1B9FC8", "versionEndExcluding": "4.8", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:4.8:-:*:*:*:*:*:*", "matchCriteriaId": "FCC0EE8B-1088-46B6-992A-B8E12A7B7DC2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "C6619B0F-7CDC-40A6-89B2-C6067AF45214", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "31393A1B-4DBC-476D-875E-463B4B887E1B", "versionEndExcluding": "4.8", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:4.8:-:*:*:*:*:*:*", "matchCriteriaId": "0206F9F2-27C7-4D2F-817B-13F8FA31E547", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*", "matchCriteriaId": "444DD77F-DB65-4766-A89D-7A679B4CA1E1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FC70D596-AA1E-4196-87B0-BECEE6568AA7", "versionEndExcluding": "5.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_sm150_firmware:5.1:-:*:*:*:*:*:*", "matchCriteriaId": "1E81CDB5-122F-48D1-B9F1-4C401D46D978", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "2AE231E2-2B2B-407A-BF7A-9EA35F394229", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "The webserver of the affected devices contains a vulnerability that may lead to\r\na denial of service condition. An attacker may cause a denial of service\r\nsituation which leads to a restart of the webserver of the affected device.\r\n\r\nThe security vulnerability could be exploited by an attacker with network\r\naccess to the affected systems. Successful exploitation requires no system\r\nprivileges and no user interaction. An attacker could use the vulnerability\r\nto compromise availability of the device." }, { "lang": "es", "value": "SIPLUS), paneles exteriores SIMATIC HMI Comfort de 7\" y 15\" (incl. variantes SIPLUS), paneles SIMATIC HMI Comfort de 4\" - 22\" (incl. variantes SIPLUS), paneles SIMATIC ET 200SP Open Controller CPU 1515SP PC SIPLUS), paneles m\u00f3viles SIMATIC HMI KTP KTP400F, KTP700, KTP700F, KTP900 y KTP900F, SIMATIC IPC DiagMonitor, SIMATIC RF182C, SIMATIC RF185C, SIMATIC RF186C, SIMATIC RF188C, familia SIMATIC RF600R, familia de CPUs SIMATIC S7-1500 (incl. CPUs ET200 y variantes SIPLUS), controlador de software SIMATIC S7-1500, familia de CPUs SIMATIC S7-300 (incluidas las CPUs ET200 y variantes SIPLUS), familia de CPUs SIMATIC S7-400 PN/DP V6 e inferiores (incluidas las variantes SIPLUS), familia de CPUs SIMATIC S7-400 PN/DP V7 (incluidas las variantes SIPLUS) SIPLUS), SIMATIC S7-PLCSIM Advanced, SIMATIC Teleservice Adapter IE Advanced, SIMATIC Teleservice Adapter IE Basic, SIMATIC Teleservice Adapter IE Standard, SIMATIC WinAC RTX (F) 2010, SIMATIC WinCC Runtime Advanced, SIMOCODE pro V EIP (incl. SIPLUS), SIMOCODE pro V PN (incl. variantes SIPLUS), SINAMICS G130 V4.6 Control Unit, SINAMICS G130 V4.7 Control Unit, SINAMICS G130 V4.7 SP1 Control Unit, SINAMICS G130 V4.8 Control Unit, SINAMICS G130 V5.1 Control Unit, SINAMICS G130 V5. 1 SP1 Unidad de control, SINAMICS G150 V4.6 Unidad de control, SINAMICS G150 V4.7 Unidad de control, SINAMICS G150 V4.7 SP1 Unidad de control, SINAMICS G150 V4.8 Unidad de control, SINAMICS G150 V5. 1 Unidad de control, SINAMICS G150 V5.1 SP1 Unidad de control, SINAMICS GH150 V4.7 (Unidad de control), SINAMICS GH150 V4.8 (Unidad de control), SINAMICS GL150 V4.7 (Unidad de control), SINAMICS GL150 V4. 8 (Unidad de control), SINAMICS GM150 V4.7 (Unidad de control), SINAMICS GM150 V4.8 (Unidad de control), SINAMICS S120 V4.6 Unidad de control (incl. variantes SIPLUS), SINAMICS S120 V4.7 Unidad de control (incl. variantes SIPLUS) SIPLUS), SINAMICS S120 V4.7 SP1 (incl. variantes SIPLUS), SINAMICS S120 V4.8 (incl. variantes SIPLUS), SINAMICS S120 V5.1 (incl. variantes SIPLUS) SIPLUS), SINAMICS S120 V5.1 SP1 Unidad de Control (incl. variantes SIPLUS), SINAMICS S150 V4.6 Unidad de Control, SINAMICS S150 V4.7 Unidad de Control, SINAMICS S150 V4.7 SP1 Unidad de Control, SINAMICS S150 V4. 8 Unidad de control, SINAMICS S150 V5.1 Unidad de control, SINAMICS S150 V5.1 SP1 Unidad de control, SINAMICS S210 V5.1 Unidad de control, SINAMICS S210 V5.1 SP1 Unidad de control, SINAMICS SL150 V4. 7 (Unidad de Control), SINAMICS SL150 V4.8 (Unidad de Control), SINAMICS SM120 V4.7 (Unidad de Control), SINAMICS SM120 V4.8 (Unidad de Control), SINAMICS SM150 V4. 8 (unidad de control), SIPLUS NET CP 343-1 Advanced, SIPLUS NET CP 443-1, SIPLUS NET CP 443-1 Advanced, SITOP Manager, SITOP PSU8600, SITOP UPS1600 (incl. variantes SIPLUS), TIM 1531 IRC (incl. variantes SIPLUS NET). El servidor web de los dispositivos afectados contiene una vulnerabilidad que puede conducir a una condici\u00f3n de denegaci\u00f3n de servicio. Un atacante puede provocar una situaci\u00f3n de denegaci\u00f3n de servicio que lleve a reiniciar el servidor web del dispositivo afectado. La vulnerabilidad de seguridad podr\u00eda ser explotada por un atacante con acceso a la red de los sistemas afectados. La explotaci\u00f3n exitosa no requiere privilegios del sistema ni interacci\u00f3n del usuario. Un atacante podr\u00eda utilizar la vulnerabilidad para comprometer la disponibilidad del dispositivo" } ], "id": "CVE-2019-6568", "lastModified": "2024-11-21T04:46:42.773", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Secondary" } ] }, "published": "2019-04-17T14:29:03.683", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2021-05-12 14:15
Modified
2024-11-21 05:55
Severity ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC client fails to handle an exception properly if the program execution process is modified after sending a packet from the server, which could result in a Denial-of-Service condition.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Vendor Advisory | |
productcert@siemens.com | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | Third Party Advisory, US Government Resource |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0891D85-C5F4-4CD2-8EFA-84356CE36654", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:-:*:*:*:*:*:*", "matchCriteriaId": "E0005A53-33AD-47AF-B172-CAF423DE213F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update1:*:*:*:*:*:*", "matchCriteriaId": "9696B0D9-5A66-4747-9437-791EAC150DDA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update2:*:*:*:*:*:*", "matchCriteriaId": "F6AC2BA5-1668-4B71-8812-925AC6554F5A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update3:*:*:*:*:*:*", "matchCriteriaId": "047D0868-3DA6-41CF-A6F9-D15668D536FB", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "244D9B27-649C-4983-B374-6A8774771AC5", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "A2530BB3-484C-4D24-82F6-15967C8B7B32", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "B5A1FACE-E693-4FDA-944D-0B7F500007B6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D7FB4AA4-1F48-4A25-AA21-5F867A38D23E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "6A673BD0-96B5-48CA-B060-A5D01687A764", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "428B633D-55FF-4DB8-B6DD-5E4EEE52A44C", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:*:*:*:*:*:*:*", "matchCriteriaId": "C33A64DD-22A2-4260-929F-7595CD037823", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "9756D206-E295-4B0C-B159-F9A953342E37", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "82D6FBBF-FD9B-4AFA-B3E1-8E3341948A37", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D43D2191-DBBD-4F7A-B02A-3DCEE46BF904", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "23C6AD3C-C15B-4B67-88D1-236C10BB12CF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FEE4201E-E660-4B3E-91EC-B6A7DC35C189", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "F2D6D924-858A-4542-BCD0-A5631F941039", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "309E4D56-6D39-4E8F-8312-FF178B721392", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "EDB63639-3101-4F60-8193-EF219D99C128", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "4C6C83EE-3DC7-4CB3-8148-CB24A825274E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C6C72B0-17D7-491E-816A-AF855166A90B", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "322584EF-72C0-4032-A02B-FDFFDCCE3FDE", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "C3D5F1BA-2BEA-40A9-8D5B-A612D467C40C", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D14DE5C7-318A-4D08-BB39-1E43F624816A", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "FCDAF23F-9272-4DC5-8D46-37FAC08950CC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "21FB0305-DF87-42FF-BACA-E8255EA74AA9", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "BAA5B299-A45A-4918-AB8F-03A476CEDA17", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "0C29FD64-C041-4269-BC52-8F91321BC247", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "7182C6C0-7DAD-4446-B14E-8EF46FB0CFA9", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "44F6F972-26AF-4A6E-AAD9-B30EBDF52465", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E57B8F3D-5E02-4F0F-9927-9D7C336EBE56", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "845C78A9-AE0F-42B9-9E25-47F541DF5196", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "B23096F5-3546-41D8-BE30-8698BC0C9B42", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D7C5AF13-69FF-444F-B84A-130D7413B307", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "66A17FC6-B6AE-4915-8069-68B41F3C87E2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4C618736-1382-4515-A295-6EC67A2731EA", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "BC0AD5A8-768E-4747-AD89-B924D369565E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "4C2FD1E4-4A01-4BFB-9D2A-5A030C37BD96", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "0AA5C3DC-E67F-4773-B32C-6B362C94BCBE", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "C96C7676-9A0D-46B5-9C49-5F5CE873E2C1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AF42C3EA-84A5-4419-ACBA-6A2F8DB994E2", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "105CCE4B-D8F9-43EA-9089-CEE16A410751", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "7C163E7E-C9E3-4FBD-885A-C2E7FB8B845F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "2CD3DD84-BDAC-4583-BD61-799A5F01A5B4", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "0A4F6758-0B36-4546-A7A7-A4C71B63772E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "12A613F7-4EA4-40FF-931F-EF3C477300DA", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "4B048552-A26D-419E-9EEA-9AFD9457B70B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "0E4E1016-F217-4B75-83D7-F73B1C5A54F9", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "EF2F6982-2C38-4F9B-87A4-AE4404197B7A", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "7745AA84-BC12-4DBD-90A6-DA294EADB7BF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "67CFFD89-1FF2-4F25-A5AB-D6FF8F721132", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "BA4B198A-8288-459D-9586-CD402DE23023", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "AC4FDB83-702A-41D5-B2A5-BDA58B7E13D2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "D972823A-1128-4222-8910-9CA3D38B472F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "A05007D7-3C49-4192-ABDF-FE94BA7FD1D1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "869AD837-79B1-4F76-947B-7DCAD172BDC0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "5C152EB8-A13A-4F16-994A-B6D93A017CC3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "42F38FBA-7D23-4CB2-9A2D-45616E2A2DFB", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "553C9A57-A9D2-47F9-ABA8-042B05DE46C7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "8F5F3B33-2A82-4CDF-A678-76DE13F256D7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "9FE49F2D-B904-4E48-AAFD-669141B570F6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "729F784C-9AC0-4231-A75A-1FA8373FA31F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "FA61AC05-061D-4EE7-BFEF-568F30B9B883", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "374BAF2F-0A32-4F1A-B838-894F9E9D3E0F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C636FCD-78AE-4FA2-95E5-2BBD5A88DA68", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "FDE42199-9152-41A3-BE56-E6789315CF28", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "040F990F-F3C2-46EF-9E40-FD136A19575F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "748BFFBC-56BD-42EC-9B5F-0752D2A70D17", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "B37490B0-A214-4A62-9B67-934048921C1E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "3D7B9F45-5749-4F36-961D-6C5D650ADA07", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "F544593D-368B-4EC1-8448-8C2BA1301216", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A9D26D9F-7081-42B2-8AE4-D04E8429B88D", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "5F902732-9944-4821-BCFB-9937D1301FF6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "B0C061AC-3E64-4667-A0E7-DD58B2E5A014", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "3EECF743-25E8-4483-AA68-B304B38A9290", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "2F557157-AAD6-4601-84C2-2F8574F23683", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "A6BF6644-AF29-4541-9D6A-D07D0CC026F0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "C4FD5396-8094-4DD0-BE7B-0FB6CC6D45F1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A8EC6926-258F-4F5C-88D2-33FE363340DB", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "97E283EF-A950-40E7-91C7-839203A333A5", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "B5B130C2-28B8-464C-981C-B5662B4B4309", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "79407355-4181-4082-A661-C27734D95363", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "8989C7D4-5246-443E-B6E4-8E91462B2E96", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "2BFBC5B2-B00B-4FCD-86B1-A187122035AB", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "B47671A7-A8DB-4DA2-9076-78708C7F1C42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D9CF819-E06C-4EAA-85B3-AC40E039D485", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "4AF727E5-7849-4980-8AA5-7469FD52DF86", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "F36ABC58-C9FE-4F4A-AB81-26D48A79FFD2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "A87DD9FF-9CA3-4AE2-8C86-C30A779E0CE6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "891AF48F-1F4D-4AB8-AE66-FBABDD2CAA76", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "5052CB07-626A-46C4-8966-B8C9325A3BB3", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "6CD47CC7-1414-42C9-94C6-9DBC2C1D9CBE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B28FB484-526A-437E-80E3-B62F54F1BEF6", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "61DFC57F-0359-4B4A-A13C-067B21D3DA7B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "81CE70BF-EBBE-4CD7-999C-25662670EFCB", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "034B7CFC-1234-4914-8C84-7E5BD5FB6E4D", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "221EB3AE-1420-46F8-9EAD-1914503B0435", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "5F9A416C-277F-44B0-A74C-263CB0C37D03", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "FA858127-69A0-4280-80A8-65E0778A90AD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "66FC2264-7DDD-4BEF-9795-AC6A5A00886B", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "D68363A9-D1D5-4E49-98D1-E5F8C324BC22", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "A35D0B0C-695D-4274-8B9E-69ED20B62585", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "FE9C9981-BA54-48BB-A89D-3CA06C7E17C6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "EA400339-123F-494A-8CD8-7232281E7D29", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "C8E943A5-E35C-4CFA-8998-A74385C8740B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "F4D7038E-C705-4FB9-A2D3-82FFC8EE80CC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8E4F0084-91A5-4D7E-971B-9DB979849594", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "36EEF9EB-91EF-4697-A963-7C8F955778EC", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "AA0728BD-F463-456C-A6EB-9FF2FD42AA23", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "7BB0B884-C99A-4854-992F-8588840CC296", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "04BA4916-5693-4915-B4D7-29D97FA02474", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "DC588CE7-1F9D-43EF-A478-C23C8D909685", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "2DE08529-E210-48C1-A7C3-D2D316902A40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "06364800-4C54-4BE4-B4AA-0CF29E4E82AA", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "4FBDFA7B-504A-4F58-967F-15CAFCEB5594", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "4D184A8F-963A-4730-AED4-1994EEA91702", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "16DAC92E-141C-4923-96F5-2620F60E763A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "B3300D8B-E0A1-4CEF-8BE0-AED3F19E9015", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "8104E528-ED7D-451E-8834-057295A7FF49", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "0AF02DF4-7190-4F6C-8F15-37581FFC9B86", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4). SmartVNC client fails to handle an exception properly if the program execution process is modified after sending a packet from the server, which could result in a Denial-of-Service condition." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (Todas las versiones anteriores a V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (Todas las versiones anteriores a V16 Update 4). El cliente SmartVNC presenta un fallo al manejar una excepci\u00f3n apropiadamente si el proceso de ejecuci\u00f3n del programa es modificado despu\u00e9s de enviar un paquete desde el servidor, lo que podr\u00eda resultar en una condici\u00f3n de Denegaci\u00f3n de Servicio" } ], "id": "CVE-2021-25662", "lastModified": "2024-11-21T05:55:14.660", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-05-12T14:15:11.343", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-755" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-06-10 17:15
Modified
2024-11-21 05:37
Severity ?
Summary
A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf | Vendor Advisory | |
productcert@siemens.com | https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04 | Third Party Advisory, US Government Resource |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_automatic_tool:*:*:*:*:*:*:*:*", "matchCriteriaId": "A659B687-1038-42F5-B8AC-A394E41D22A8", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_net_pc:*:*:*:*:*:*:*:*", "matchCriteriaId": "744B5953-511F-42CA-80A0-DBE36A6AA144", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_net_pc:16:-:*:*:*:*:*:*", "matchCriteriaId": "496E3C43-5DA8-4983-8AC6-0F32454E22F3", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_net_pc:16:update1:*:*:*:*:*:*", "matchCriteriaId": "17BCC3CD-61D0-416D-A241-D35AF8EE5BF8", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*", "matchCriteriaId": "13E3BDF0-B691-4A97-A74A-A65EC910480E", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*", "matchCriteriaId": "D61D4B81-7F51-49BE-83DD-D2C28D23B0EA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_prosave:*:*:*:*:*:*:*:*", "matchCriteriaId": "CB7752CF-D754-4A78-999B-45FE379E03DE", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:*", "matchCriteriaId": "658E1A3F-29D6-48D2-BCCE-0BCC41AC49F6", "versionEndExcluding": "21.8", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*", "matchCriteriaId": "CAF09D6E-3375-4731-B16D-30B7592EA5FB", "versionEndExcluding": "5.6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*", "matchCriteriaId": "1A3CA33C-AFAB-418F-870F-0236B8E55943", "versionEndIncluding": "16", "versionStartIncluding": "13", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:5.6:-:*:*:*:*:*:*", "matchCriteriaId": "851F8474-4568-487D-98FB-47DF7EAEAC3B", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:5.6:sp1:*:*:*:*:*:*", "matchCriteriaId": "81EADA2F-884C-4D72-8489-71025B3EBAEE", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:5.6:sp2:*:*:*:*:*:*", "matchCriteriaId": "78366D2F-B728-47F6-B539-5FB2D1B0419D", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:5.6:sp2_hotfix1:*:*:*:*:*:*", "matchCriteriaId": "06A86DA0-BC1F-4306-B02E-ED2FA36BE273", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*", "matchCriteriaId": "3F39B396-140B-4005-9A61-F984C9FAF742", "versionEndExcluding": "7.4", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:-:*:*:*:*:*:*", "matchCriteriaId": "3B0BD5DE-C6EF-4B89-831B-DA34DB0D68F6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1:*:*:*:*:*:*", "matchCriteriaId": "2637C346-8AAF-481F-AFB0-BAD4254D14F4", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update1:*:*:*:*:*:*", "matchCriteriaId": "BF8404AB-579E-4C6B-BCA7-E95F2CE24F7D", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update10:*:*:*:*:*:*", "matchCriteriaId": "88F6B3BF-727F-432E-89D8-37FB7C76FE2B", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update11:*:*:*:*:*:*", "matchCriteriaId": "62EB588C-CBB4-4B17-9BB5-B14B1FC6BB21", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update12:*:*:*:*:*:*", "matchCriteriaId": "AF3F613C-6707-4517-B4B8-530C912B79E6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update13:*:*:*:*:*:*", "matchCriteriaId": "590F62CE-9245-4AC9-9FBC-35136E217B0E", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update2:*:*:*:*:*:*", "matchCriteriaId": "241D5A28-FB22-4C5B-A067-733168E847BF", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update3:*:*:*:*:*:*", "matchCriteriaId": "A5418F92-84A9-439C-B86C-ED5820697603", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update4:*:*:*:*:*:*", "matchCriteriaId": "40631FBD-116B-4589-B77A-6C5A69990F73", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update5:*:*:*:*:*:*", "matchCriteriaId": "64B14972-6163-4D44-A9C6-16328E02AC69", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update6:*:*:*:*:*:*", "matchCriteriaId": "8929E926-740F-4F17-B52C-4C73914B1818", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update7:*:*:*:*:*:*", "matchCriteriaId": "D4F72666-D10A-4EB2-80D3-18B04C101256", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update8:*:*:*:*:*:*", "matchCriteriaId": "0E343221-1E1A-4EE7-80AE-AB24E2244BA0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update9:*:*:*:*:*:*", "matchCriteriaId": "1BF716D7-0A77-400F-9B43-64FBE3E65735", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:-:*:*:*:*:*:*", "matchCriteriaId": "E79DA14E-419C-49BA-8E4F-2907E1D8937F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1:*:*:*:*:*:*", "matchCriteriaId": "81F9C13C-065C-4E40-BB46-687D791348A9", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update1:*:*:*:*:*:*", "matchCriteriaId": "5CF06E69-0A23-418D-B0EC-574DACBB4DD9", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update2:*:*:*:*:*:*", "matchCriteriaId": "9164EAC1-C416-4F1F-A910-CE84A167A6D1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_open_architecture:3.16:*:*:*:*:*:*:*", "matchCriteriaId": "4B9ED7EF-EF58-400F-92C9-3D52D8E39783", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_open_architecture:3.17:*:*:*:*:*:*:*", "matchCriteriaId": "1C3F9210-7A1E-4B10-B384-119FD5733A86", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "79EE15DC-74D3-4551-AAD0-EA0CB600DA76", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:*:*:*:*:*:*:*:*", "matchCriteriaId": "3C9253AD-BD82-4BB2-84AD-EB1892B60358", "versionEndIncluding": "16", "versionStartIncluding": "13", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinamics_startdrive:*:*:*:*:*:*:*:*", "matchCriteriaId": "C11DB09A-74E1-45EF-A162-9C1E91F54C04", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinamics_starter_commissioning_tool:*:*:*:*:*:*:*:*", "matchCriteriaId": "1976CDDA-F2AF-4C47-804E-2C1DF44FBF41", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinec_network_management_system:*:*:*:*:*:*:*:*", "matchCriteriaId": "52F7076E-12F7-4F62-9804-18598C39D3FF", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinema_server:*:*:*:*:*:*:*:*", "matchCriteriaId": "C55DA617-6333-40DA-AB7D-EE49A453E143", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinumerik_one_virtual:*:*:*:*:*:*:*:*", "matchCriteriaId": "A607E4B7-2F58-4F68-91EB-16874986E92F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinumerik_operate:*:*:*:*:*:*:*:*", "matchCriteriaId": "BAFC5C25-EC3C-4EB6-B5B2-478AE9CEF10F", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC Automation Tool (All versions \u003c V4 SP2), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions \u003c V16 Upd3), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC ProSave (All versions \u003c V17), SIMATIC S7-1500 Software Controller (All versions \u003c V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions \u003c V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMATIC STEP 7 V5 (All versions \u003c V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions \u003c V3.16 P018), SIMATIC WinCC OA V3.17 (All versions \u003c V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions \u003c V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions \u003c V16 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP1 Update 3), SINAMICS STARTER (All Versions \u003c V5.4 HF2), SINAMICS Startdrive (All Versions \u003c V16 Update 3), SINEC NMS (All versions \u003c V1.0 SP2), SINEMA Server (All versions \u003c V14 SP3), SINUMERIK ONE virtual (All Versions \u003c V6.14), SINUMERIK Operate (All Versions \u003c V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC Automation Tool (Todas las versiones anteriores a la versi\u00f3n V4 SP2), SIMATIC NET PC Software V14 (Todas las versiones anteriores a la versi\u00f3n V14 SP1 Update 14), SIMATIC NET PC Software V15 (Todas las versiones), SIMATIC NET PC Software V16 (Todas las versiones anteriores a la versi\u00f3n V16 Upd3), SIMATIC PCS neo (Todas las versiones anteriores a la versi\u00f3n V3.0 SP1), SIMATIC ProSave (Todas las versiones anteriores a la versi\u00f3n V17), SIMATIC S7-1500 Software Controller (Todas las versiones anteriores a la versi\u00f3n V21. 8), SIMATIC STEP 7 (Todas las versiones anteriores a la versi\u00f3n V5.6 SP2 HF3), SIMATIC STEP 7 (TIA Portal) V13 (Todas las versiones anteriores a la versi\u00f3n V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (Todas las versiones anteriores a la versi\u00f3n V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (Todas las versiones anteriores a la versi\u00f3n V15. 1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (Todas las versiones anteriores a la versi\u00f3n V16 Update 2), SIMATIC WinCC OA V3.16 (Todas las versiones anteriores a la versi\u00f3n V3.16 P018), SIMATIC WinCC OA V3. 17 (Todas las versiones anteriores a la versi\u00f3n V3.17 P003), SIMATIC WinCC Runtime Advanced (Todas las versiones anteriores a la versi\u00f3n V16 Update 2), SIMATIC WinCC Runtime Professional V13 (Todas las versiones anteriores a la versi\u00f3n V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (Todas las versiones anteriores a la versi\u00f3n V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (Todas las versiones anteriores a la versi\u00f3n V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (Todas las versiones anteriores a la versi\u00f3n V16 Update 2), SIMATIC WinCC V7. 4 (Todas las versiones anteriores a la versi\u00f3n V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (Todas las versiones anteriores a la versi\u00f3n V7.5 SP1 Update 3), SINAMICS STARTER (Todas las versiones anteriores a la versi\u00f3n V5.4 HF2), SINAMICS Startdrive (Todas las versiones anteriores a la versi\u00f3n V16 Update 3), SINEC NMS (Todas las versiones anteriores a la versi\u00f3n V1. 0 SP2), SINEMA Server (Todas las versiones anteriores a la versi\u00f3n V14 SP3), SINUMERIK ONE virtual (Todas las versiones anteriores a la versi\u00f3n V6.14), SINUMERIK Operate (Todas las versiones anteriores a la versi\u00f3n V6.14). Un componente dentro de la aplicaci\u00f3n afectada llama regularmente a un binario de ayuda con privilegios de SISTEMA mientras la ruta de llamada no est\u00e1 citada" } ], "id": "CVE-2020-7580", "lastModified": "2024-11-21T05:37:24.840", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-10T17:15:12.347", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-428" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-428" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2021-05-12 14:15
Modified
2024-11-21 05:57
Severity ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | Vendor Advisory | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Vendor Advisory | |
productcert@siemens.com | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | Third Party Advisory, US Government Resource |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0891D85-C5F4-4CD2-8EFA-84356CE36654", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:-:*:*:*:*:*:*", "matchCriteriaId": "E0005A53-33AD-47AF-B172-CAF423DE213F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update1:*:*:*:*:*:*", "matchCriteriaId": "9696B0D9-5A66-4747-9437-791EAC150DDA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update2:*:*:*:*:*:*", "matchCriteriaId": "F6AC2BA5-1668-4B71-8812-925AC6554F5A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update3:*:*:*:*:*:*", "matchCriteriaId": "047D0868-3DA6-41CF-A6F9-D15668D536FB", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sh150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0F1FAFD2-1E4D-44F3-87A1-8A1380B980BC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sh150:-:*:*:*:*:*:*:*", "matchCriteriaId": "EBC7AA8D-9046-4111-A263-38343997F984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm150i_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D6067521-A21D-4B2A-AFB2-2E033F66B63E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm150i:-:*:*:*:*:*:*:*", "matchCriteriaId": "A44DEAD8-8DB8-41CC-9495-B842BE76EA8F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4BF9157D-0089-4569-9AA1-4DEE94140D25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*", "matchCriteriaId": "BF977545-395A-4C34-BB22-A1047B5B6E85", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4D780400-0AA8-449C-B754-7167CA878D3D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DED7F33B-D475-4232-8683-48554A6729F7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "61CD50EE-6C46-445E-8D46-82768CAAC305", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E032554B-7F51-4482-AF55-743FFB5AC352", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "C6619B0F-7CDC-40A6-89B2-C6067AF45214", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CFFE3048-EEB0-48A0-BED0-8647284B022B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*", "matchCriteriaId": "444DD77F-DB65-4766-A89D-7A679B4CA1E1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33B7E1DE-61B5-4CFC-8640-EB8029CD79D6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "2AE231E2-2B2B-407A-BF7A-9EA35F394229", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "244D9B27-649C-4983-B374-6A8774771AC5", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "A2530BB3-484C-4D24-82F6-15967C8B7B32", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "B5A1FACE-E693-4FDA-944D-0B7F500007B6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D7FB4AA4-1F48-4A25-AA21-5F867A38D23E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "6A673BD0-96B5-48CA-B060-A5D01687A764", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "428B633D-55FF-4DB8-B6DD-5E4EEE52A44C", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:*:*:*:*:*:*:*", "matchCriteriaId": "C33A64DD-22A2-4260-929F-7595CD037823", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "9756D206-E295-4B0C-B159-F9A953342E37", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "82D6FBBF-FD9B-4AFA-B3E1-8E3341948A37", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D43D2191-DBBD-4F7A-B02A-3DCEE46BF904", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "23C6AD3C-C15B-4B67-88D1-236C10BB12CF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FEE4201E-E660-4B3E-91EC-B6A7DC35C189", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "F2D6D924-858A-4542-BCD0-A5631F941039", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "309E4D56-6D39-4E8F-8312-FF178B721392", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "EDB63639-3101-4F60-8193-EF219D99C128", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "4C6C83EE-3DC7-4CB3-8148-CB24A825274E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C6C72B0-17D7-491E-816A-AF855166A90B", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "322584EF-72C0-4032-A02B-FDFFDCCE3FDE", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "C3D5F1BA-2BEA-40A9-8D5B-A612D467C40C", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D14DE5C7-318A-4D08-BB39-1E43F624816A", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "FCDAF23F-9272-4DC5-8D46-37FAC08950CC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "21FB0305-DF87-42FF-BACA-E8255EA74AA9", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "BAA5B299-A45A-4918-AB8F-03A476CEDA17", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "0C29FD64-C041-4269-BC52-8F91321BC247", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "7182C6C0-7DAD-4446-B14E-8EF46FB0CFA9", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "44F6F972-26AF-4A6E-AAD9-B30EBDF52465", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E57B8F3D-5E02-4F0F-9927-9D7C336EBE56", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "845C78A9-AE0F-42B9-9E25-47F541DF5196", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "B23096F5-3546-41D8-BE30-8698BC0C9B42", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D7C5AF13-69FF-444F-B84A-130D7413B307", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "66A17FC6-B6AE-4915-8069-68B41F3C87E2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4C618736-1382-4515-A295-6EC67A2731EA", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "BC0AD5A8-768E-4747-AD89-B924D369565E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "4C2FD1E4-4A01-4BFB-9D2A-5A030C37BD96", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "0AA5C3DC-E67F-4773-B32C-6B362C94BCBE", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "C96C7676-9A0D-46B5-9C49-5F5CE873E2C1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AF42C3EA-84A5-4419-ACBA-6A2F8DB994E2", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "105CCE4B-D8F9-43EA-9089-CEE16A410751", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "7C163E7E-C9E3-4FBD-885A-C2E7FB8B845F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "2CD3DD84-BDAC-4583-BD61-799A5F01A5B4", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "0A4F6758-0B36-4546-A7A7-A4C71B63772E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "12A613F7-4EA4-40FF-931F-EF3C477300DA", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "4B048552-A26D-419E-9EEA-9AFD9457B70B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "0E4E1016-F217-4B75-83D7-F73B1C5A54F9", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "EF2F6982-2C38-4F9B-87A4-AE4404197B7A", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "7745AA84-BC12-4DBD-90A6-DA294EADB7BF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "67CFFD89-1FF2-4F25-A5AB-D6FF8F721132", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "BA4B198A-8288-459D-9586-CD402DE23023", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "AC4FDB83-702A-41D5-B2A5-BDA58B7E13D2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "D972823A-1128-4222-8910-9CA3D38B472F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "A05007D7-3C49-4192-ABDF-FE94BA7FD1D1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "869AD837-79B1-4F76-947B-7DCAD172BDC0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "5C152EB8-A13A-4F16-994A-B6D93A017CC3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "42F38FBA-7D23-4CB2-9A2D-45616E2A2DFB", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "553C9A57-A9D2-47F9-ABA8-042B05DE46C7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "8F5F3B33-2A82-4CDF-A678-76DE13F256D7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "9FE49F2D-B904-4E48-AAFD-669141B570F6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "729F784C-9AC0-4231-A75A-1FA8373FA31F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "FA61AC05-061D-4EE7-BFEF-568F30B9B883", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "374BAF2F-0A32-4F1A-B838-894F9E9D3E0F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C636FCD-78AE-4FA2-95E5-2BBD5A88DA68", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "FDE42199-9152-41A3-BE56-E6789315CF28", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "040F990F-F3C2-46EF-9E40-FD136A19575F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "748BFFBC-56BD-42EC-9B5F-0752D2A70D17", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "B37490B0-A214-4A62-9B67-934048921C1E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "3D7B9F45-5749-4F36-961D-6C5D650ADA07", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "F544593D-368B-4EC1-8448-8C2BA1301216", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A9D26D9F-7081-42B2-8AE4-D04E8429B88D", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "5F902732-9944-4821-BCFB-9937D1301FF6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "B0C061AC-3E64-4667-A0E7-DD58B2E5A014", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "3EECF743-25E8-4483-AA68-B304B38A9290", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "2F557157-AAD6-4601-84C2-2F8574F23683", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "A6BF6644-AF29-4541-9D6A-D07D0CC026F0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "C4FD5396-8094-4DD0-BE7B-0FB6CC6D45F1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A8EC6926-258F-4F5C-88D2-33FE363340DB", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "97E283EF-A950-40E7-91C7-839203A333A5", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "B5B130C2-28B8-464C-981C-B5662B4B4309", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "79407355-4181-4082-A661-C27734D95363", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "8989C7D4-5246-443E-B6E4-8E91462B2E96", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "2BFBC5B2-B00B-4FCD-86B1-A187122035AB", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "B47671A7-A8DB-4DA2-9076-78708C7F1C42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D9CF819-E06C-4EAA-85B3-AC40E039D485", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "4AF727E5-7849-4980-8AA5-7469FD52DF86", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "F36ABC58-C9FE-4F4A-AB81-26D48A79FFD2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "A87DD9FF-9CA3-4AE2-8C86-C30A779E0CE6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "891AF48F-1F4D-4AB8-AE66-FBABDD2CAA76", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "5052CB07-626A-46C4-8966-B8C9325A3BB3", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "6CD47CC7-1414-42C9-94C6-9DBC2C1D9CBE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B28FB484-526A-437E-80E3-B62F54F1BEF6", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "61DFC57F-0359-4B4A-A13C-067B21D3DA7B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "81CE70BF-EBBE-4CD7-999C-25662670EFCB", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "034B7CFC-1234-4914-8C84-7E5BD5FB6E4D", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "221EB3AE-1420-46F8-9EAD-1914503B0435", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "5F9A416C-277F-44B0-A74C-263CB0C37D03", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "FA858127-69A0-4280-80A8-65E0778A90AD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "66FC2264-7DDD-4BEF-9795-AC6A5A00886B", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "D68363A9-D1D5-4E49-98D1-E5F8C324BC22", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "A35D0B0C-695D-4274-8B9E-69ED20B62585", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "FE9C9981-BA54-48BB-A89D-3CA06C7E17C6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "EA400339-123F-494A-8CD8-7232281E7D29", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "C8E943A5-E35C-4CFA-8998-A74385C8740B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "F4D7038E-C705-4FB9-A2D3-82FFC8EE80CC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8E4F0084-91A5-4D7E-971B-9DB979849594", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "36EEF9EB-91EF-4697-A963-7C8F955778EC", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "AA0728BD-F463-456C-A6EB-9FF2FD42AA23", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "7BB0B884-C99A-4854-992F-8588840CC296", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "04BA4916-5693-4915-B4D7-29D97FA02474", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "DC588CE7-1F9D-43EF-A478-C23C8D909685", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "2DE08529-E210-48C1-A7C3-D2D316902A40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "06364800-4C54-4BE4-B4AA-0CF29E4E82AA", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "4FBDFA7B-504A-4F58-967F-15CAFCEB5594", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "4D184A8F-963A-4730-AED4-1994EEA91702", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "16DAC92E-141C-4923-96F5-2620F60E763A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "B3300D8B-E0A1-4CEF-8BE0-AED3F19E9015", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "8104E528-ED7D-451E-8834-057295A7FF49", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "0AF02DF4-7190-4F6C-8F15-37581FFC9B86", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (Todas las versiones anteriores a V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (Todas las versiones anteriores a V16 Update 4), SINAMICS GH150 (Todas las versiones), SINAMICS GL150 (con la opci\u00f3n X30) (Todas las versiones), SINAMICS GM150 (with option X30) (Todas las versiones), SINAMICS SH150 (Todas las versiones), SINAMICS SL150 (Todas las versiones), SINAMICS SM120 (Todas las versiones), SINAMICS SM150 (Todas las versiones), SINAMICS SM150i (Todas las versiones). SmartVNC tiene una vulnerabilidad de fuga de asignaci\u00f3n de heap en el codificador Tight del servidor, que podr\u00eda dar lugar a una condici\u00f3n de denegaci\u00f3n de servicio" } ], "id": "CVE-2021-27383", "lastModified": "2024-11-21T05:57:53.060", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-05-12T14:15:11.633", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-770" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-770" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2021-03-25 15:15
Modified
2024-11-21 06:21
Severity ?
Summary
An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j).
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:openssl:openssl:*:*:*:*:*:*:*:*", "matchCriteriaId": "B213E696-A6D9-45E7-B4E4-E4CFE54ECEB8", "versionEndExcluding": "1.1.1k", "versionStartIncluding": "1.1.1", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:debian:debian_linux:9.0:*:*:*:*:*:*:*", "matchCriteriaId": "DEECE5FC-CACF-4496-A3E7-164736409252", "vulnerable": true }, { "criteria": "cpe:2.3:o:debian:debian_linux:10.0:*:*:*:*:*:*:*", "matchCriteriaId": "07B237A9-69A3-4A9C-9DA0-4E06BD37AE73", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:freebsd:freebsd:12.2:-:*:*:*:*:*:*", "matchCriteriaId": "73D9C08B-8F5B-40C4-A5BD-B00D2E4C012D", "vulnerable": true }, { "criteria": "cpe:2.3:o:freebsd:freebsd:12.2:p1:*:*:*:*:*:*", "matchCriteriaId": "62A178A3-6A52-4981-9A27-FB07AD8AF778", "vulnerable": true }, { "criteria": "cpe:2.3:o:freebsd:freebsd:12.2:p2:*:*:*:*:*:*", "matchCriteriaId": "54A487B1-E5CE-4C76-87E8-518D24C5D86D", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:netapp:active_iq_unified_manager:-:*:*:*:*:vmware_vsphere:*:*", "matchCriteriaId": "3A756737-1CC4-42C2-A4DF-E1C893B4E2D5", "vulnerable": true }, { "criteria": "cpe:2.3:a:netapp:cloud_volumes_ontap_mediator:-:*:*:*:*:*:*:*", "matchCriteriaId": "280AA828-6FA9-4260-8EC1-019423B966E1", "vulnerable": true }, { "criteria": "cpe:2.3:a:netapp:e-series_performance_analyzer:-:*:*:*:*:*:*:*", "matchCriteriaId": "24B8DB06-590A-4008-B0AB-FCD1401C77C6", "vulnerable": true }, { "criteria": "cpe:2.3:a:netapp:oncommand_insight:-:*:*:*:*:*:*:*", "matchCriteriaId": "F1BE6C1F-2565-4E97-92AA-16563E5660A5", "vulnerable": true }, { "criteria": "cpe:2.3:a:netapp:oncommand_workflow_automation:-:*:*:*:*:*:*:*", "matchCriteriaId": "5735E553-9731-4AAC-BCFF-989377F817B3", "vulnerable": true }, { "criteria": "cpe:2.3:a:netapp:ontap_select_deploy_administration_utility:-:*:*:*:*:*:*:*", "matchCriteriaId": "E7CF3019-975D-40BB-A8A4-894E62BD3797", "vulnerable": true }, { "criteria": "cpe:2.3:a:netapp:santricity_smi-s_provider:-:*:*:*:*:*:*:*", "matchCriteriaId": "361B791A-D336-4431-8F68-8135BEFFAEA2", "vulnerable": true }, { "criteria": "cpe:2.3:a:netapp:snapcenter:-:*:*:*:*:*:*:*", "matchCriteriaId": "BDFB1169-41A0-4A86-8E4F-FDA9730B1E94", "vulnerable": true }, { "criteria": "cpe:2.3:a:netapp:storagegrid:-:*:*:*:*:*:*:*", "matchCriteriaId": "8ADFF451-740F-4DBA-BD23-3881945D3E40", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:tenable:log_correlation_engine:*:*:*:*:*:*:*:*", "matchCriteriaId": "4ACF85D6-6B45-43DA-9C01-F0208186F014", "versionEndExcluding": "6.0.9", "vulnerable": true }, { "criteria": "cpe:2.3:a:tenable:nessus:*:*:*:*:*:*:*:*", "matchCriteriaId": "0AC12300-9051-4C70-9941-9FE5E64B4B30", "versionEndIncluding": "8.13.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.11.0:*:*:*:*:*:*:*", "matchCriteriaId": "657682A0-54D5-4DC6-A98E-8BAF685926C4", "vulnerable": true }, { "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.11.1:*:*:*:*:*:*:*", "matchCriteriaId": "8FC5C76C-3474-4B26-8CF0-2DFAFA3D5458", "vulnerable": true }, { "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.12.0:*:*:*:*:*:*:*", "matchCriteriaId": "8661D361-71B5-4C41-A818-C89EC551D900", "vulnerable": true }, { "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.12.1:*:*:*:*:*:*:*", "matchCriteriaId": "253603DC-2D92-442A-B3A8-A63E14D8A070", "vulnerable": true }, { "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.13.0:*:*:*:*:*:*:*", "matchCriteriaId": "8E112CFF-31F9-4D87-9A1B-AE0FCF69615E", "vulnerable": true }, { "criteria": "cpe:2.3:a:tenable:tenable.sc:*:*:*:*:*:*:*:*", "matchCriteriaId": "AC1721B5-9FCD-47C3-8338-E02932CF2C05", "versionEndIncluding": "5.17.0", "versionStartIncluding": "5.13.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:fedoraproject:fedora:34:*:*:*:*:*:*:*", "matchCriteriaId": "A930E247-0B43-43CB-98FF-6CE7B8189835", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:mcafee:web_gateway:8.2.19:*:*:*:*:*:*:*", "matchCriteriaId": "DEA7F1FD-9FAB-4654-98B0-4588EEC8B69A", "vulnerable": true }, { "criteria": "cpe:2.3:a:mcafee:web_gateway:9.2.10:*:*:*:*:*:*:*", "matchCriteriaId": "868B2C4B-CE6B-41DA-A373-7D4FA51EFE9F", "vulnerable": true }, { "criteria": "cpe:2.3:a:mcafee:web_gateway:10.1.1:*:*:*:*:*:*:*", "matchCriteriaId": "550F47A2-3393-481E-BC40-CE606BFA8776", "vulnerable": true }, { "criteria": "cpe:2.3:a:mcafee:web_gateway_cloud_service:8.2.19:*:*:*:*:*:*:*", "matchCriteriaId": "43392D27-6C07-41C7-A17F-10C433338CE9", "vulnerable": true }, { "criteria": "cpe:2.3:a:mcafee:web_gateway_cloud_service:9.2.10:*:*:*:*:*:*:*", "matchCriteriaId": "8FBF6C4C-195F-49A7-861D-52677D9BE58D", "vulnerable": true }, { "criteria": "cpe:2.3:a:mcafee:web_gateway_cloud_service:10.1.1:*:*:*:*:*:*:*", "matchCriteriaId": "90732D53-E802-4E1B-B6C8-B1FDCE7905A4", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:checkpoint:quantum_security_management_firmware:r80.40:*:*:*:*:*:*:*", "matchCriteriaId": "A98B128A-C58E-48EC-B691-AF73126A0822", "vulnerable": true }, { "criteria": "cpe:2.3:o:checkpoint:quantum_security_management_firmware:r81:*:*:*:*:*:*:*", "matchCriteriaId": "345B990F-C1C4-440B-804E-0A2882FE7C01", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:checkpoint:quantum_security_management:-:*:*:*:*:*:*:*", "matchCriteriaId": "08601413-25E2-4977-B67A-C11A9D788EA8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:checkpoint:multi-domain_management_firmware:r80.40:*:*:*:*:*:*:*", "matchCriteriaId": "EFC067CC-EB90-43F5-9674-089D5C611573", "vulnerable": true }, { "criteria": "cpe:2.3:o:checkpoint:multi-domain_management_firmware:r81:*:*:*:*:*:*:*", "matchCriteriaId": "80B223A7-1039-445D-ABE1-5E481004D956", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:checkpoint:multi-domain_management:-:*:*:*:*:*:*:*", "matchCriteriaId": "1584E1B4-412C-40E2-BF07-4E464692F2AE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:checkpoint:quantum_security_gateway_firmware:r80.40:*:*:*:*:*:*:*", "matchCriteriaId": "A0002A29-8B42-445D-9EC4-58BC93194241", "vulnerable": true }, { "criteria": "cpe:2.3:o:checkpoint:quantum_security_gateway_firmware:r81:*:*:*:*:*:*:*", "matchCriteriaId": "3B0EDB21-9305-4601-AB96-A77BD00F311D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:checkpoint:quantum_security_gateway:-:*:*:*:*:*:*:*", "matchCriteriaId": "9016DDF6-285C-4E64-88D0-29ECCEF048F8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:oracle:communications_communications_policy_management:12.6.0.0.0:*:*:*:*:*:*:*", "matchCriteriaId": "570DB369-A31B-4108-A7FD-09F674129603", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:enterprise_manager_for_storage_management:13.4.0.0:*:*:*:*:*:*:*", "matchCriteriaId": "61516569-C48F-4362-B334-8CA10EDB0EC2", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:essbase:21.2:*:*:*:*:*:*:*", "matchCriteriaId": "394A16F2-CCD4-44E5-BF6B-E0C782A9FA38", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:graalvm:19.3.5:*:*:*:enterprise:*:*:*", "matchCriteriaId": "058C7C4B-D692-49DE-924A-C2725A8162D3", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:graalvm:20.3.1.2:*:*:*:enterprise:*:*:*", "matchCriteriaId": "0F0434A5-F2A1-4973-917C-A95F2ABE97D1", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:graalvm:21.0.0.2:*:*:*:enterprise:*:*:*", "matchCriteriaId": "96DD93E0-274E-4C36-99F3-EEF085E57655", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:jd_edwards_enterpriseone_tools:*:*:*:*:*:*:*:*", "matchCriteriaId": "86305E47-33E9-411C-B932-08C395C09982", "versionEndExcluding": "9.2.6.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:jd_edwards_world_security:a9.4:*:*:*:*:*:*:*", "matchCriteriaId": "0B1CAD50-749F-4ADB-A046-BF3585677A58", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:mysql_connectors:*:*:*:*:*:*:*:*", "matchCriteriaId": "A8782A14-89B0-45EE-A5CB-FF715F5BA379", "versionEndIncluding": "8.0.23", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:mysql_server:*:*:*:*:*:*:*:*", "matchCriteriaId": "5C40ECC8-933B-47A4-8082-FCF0EF9C973E", "versionEndIncluding": "5.7.33", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:mysql_server:*:*:*:*:*:*:*:*", "matchCriteriaId": "32714AD7-BCD1-4624-9923-5E6D927CF3CB", "versionEndIncluding": "8.0.23", "versionStartIncluding": "8.0.15", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:mysql_workbench:*:*:*:*:*:*:*:*", "matchCriteriaId": "CB1A94E1-A6C6-488D-A74C-6C0B24637272", "versionEndIncluding": "8.0.23", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:8.57:*:*:*:*:*:*:*", "matchCriteriaId": "7E1E416B-920B-49A0-9523-382898C2979D", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:8.58:*:*:*:*:*:*:*", "matchCriteriaId": "D9DB4A14-2EF5-4B54-95D2-75E6CF9AA0A9", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:8.59:*:*:*:*:*:*:*", "matchCriteriaId": "C8AF00C6-B97F-414D-A8DF-057E6BFD8597", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:primavera_unifier:*:*:*:*:*:*:*:*", "matchCriteriaId": "08FA59A8-6A62-4B33-8952-D6E658F8DAC9", "versionEndIncluding": "17.12", "versionStartIncluding": "17.7", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:primavera_unifier:19.12:*:*:*:*:*:*:*", "matchCriteriaId": "10864586-270E-4ACF-BDCC-ECFCD299305F", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:primavera_unifier:20.12:*:*:*:*:*:*:*", "matchCriteriaId": "38340E3C-C452-4370-86D4-355B6B4E0A06", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:primavera_unifier:21.12:*:*:*:*:*:*:*", "matchCriteriaId": "E9C55C69-E22E-4B80-9371-5CD821D79FE2", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:secure_backup:*:*:*:*:*:*:*:*", "matchCriteriaId": "C01E8B82-71C7-4A4A-A70A-7B147524AB4A", "versionEndExcluding": "18.1.0.1.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:secure_global_desktop:5.6:*:*:*:*:*:*:*", "matchCriteriaId": "9DA11710-9EA8-49B4-8FD1-3AEE442F6ADC", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:zfs_storage_appliance_kit:8.8:*:*:*:*:*:*:*", "matchCriteriaId": "D3E503FB-6279-4D4A-91D8-E237ECF9D2B0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:sonicwall:sma100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6E8B6D50-D482-43E9-A20D-FA77FD59AE2D", "versionEndExcluding": "10.2.1.0-17sv", "versionStartIncluding": "10.2.0.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:sonicwall:sma100:-:*:*:*:*:*:*:*", "matchCriteriaId": "8E4A2B7B-40F5-4AE0-ACC7-E94B82435DBA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:sonicwall:capture_client:3.5:*:*:*:*:*:*:*", "matchCriteriaId": "349EB4AE-65E3-42DC-8F9C-3A1A155324D7", "vulnerable": true }, { "criteria": "cpe:2.3:o:sonicwall:sonicos:7.0.1.0:*:*:*:*:*:*:*", "matchCriteriaId": "2BD8688A-2D55-4A7E-A143-1BD0FCF957B0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:ruggedcom_rcm1224_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5081E52B-E7C0-46BD-B1D0-2C70ABCC8831", "versionStartIncluding": "6.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:ruggedcom_rcm1224:-:*:*:*:*:*:*:*", "matchCriteriaId": "3747CDD7-E833-4B68-A362-77D6A2E9D888", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_lpe9403_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "058D21EA-E94C-4DDC-AD92-967DAC934457", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_lpe9403:-:*:*:*:*:*:*:*", "matchCriteriaId": "52A77C9D-E59C-4397-B834-797D7B334A6B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "424CD8EA-D8CB-40C7-8E0F-AC4B05C59C99", "versionStartIncluding": "6.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFB9921A-5204-40A3-88AB-B7755F5C6875", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_s602_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "858B6A84-5D0E-4E23-AE32-A45B51BAC8CF", "versionStartIncluding": "4.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_s602:-:*:*:*:*:*:*:*", "matchCriteriaId": "F4D89D82-C2CE-44DC-A05B-B956F20BF4E3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_s612_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D173626B-9C50-489F-8BA4-1C45E5F96526", "versionStartIncluding": "4.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_s612:-:*:*:*:*:*:*:*", "matchCriteriaId": "CA7B48D2-0D17-420D-AAE1-35E5C0BE2924", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E967F5FC-6F3E-4982-8813-CA1DAF3BE165", "versionStartIncluding": "6.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*", "matchCriteriaId": "E917CBBB-EF41-4113-B0CA-EB91889235E7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_s623_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81F315D8-0B26-4442-B330-85124017A482", "versionStartIncluding": "4.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_s623:-:*:*:*:*:*:*:*", "matchCriteriaId": "F80D9A79-7984-462B-B4B9-6A4429422038", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_s627-2m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6F20F735-7A70-4A24-9621-786F99C8F87D", "versionStartIncluding": "4.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_s627-2m:-:*:*:*:*:*:*:*", "matchCriteriaId": "B51B40F8-71D2-4D2D-8EC2-CE154A6D7533", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_sc-600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "973B8030-B630-4D67-B897-25A359A96185", "versionStartIncluding": "2.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_sc-600:-:*:*:*:*:*:*:*", "matchCriteriaId": "725C671B-D7A0-48CF-8A31-5F9C4173F1DD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_w700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86EA8E3F-81BD-47BC-9834-A9B69CA7E70C", "versionStartIncluding": "6.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_w700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D3033B1E-57A6-4AE3-A861-7047CF8EAD79", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_w1700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BE116AD9-B55F-41C8-8B55-329809DB63E1", "versionStartIncluding": "2.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_w1700:-:*:*:*:*:*:*:*", "matchCriteriaId": "5D9A73DD-4A21-4096-B4B6-A0A825E71006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "144CDF5E-7E07-428B-B4DF-C94992B3A44A", "versionEndExcluding": "4.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xb-200:-:*:*:*:*:*:*:*", "matchCriteriaId": "6CB3CC2D-CBF0-4F53-A412-01BBC39E34C2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "339FFBDF-6957-481F-84CE-878B5CAAD9C8", "versionEndExcluding": "4.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xc-200:-:*:*:*:*:*:*:*", "matchCriteriaId": "7719E194-EE3D-4CE8-8C85-CF0D82A553AA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xf-200ba_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6FBB13D3-4E04-4D01-B880-C16C4FFA240B", "versionEndExcluding": "4.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xf-200ba:-:*:*:*:*:*:*:*", "matchCriteriaId": "58377C58-F660-4C17-A3CB-BFC2F28848CD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xm-400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E40058B3-3726-4F6A-AB41-7679487639F2", "versionEndExcluding": "6.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xm-400:-:*:*:*:*:*:*:*", "matchCriteriaId": "798E900F-5EF9-4B39-B8C2-79FAE659E7F5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1E642D10-E701-44DF-863B-D0DAA5530F50", "versionEndExcluding": "4.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xp-200:-:*:*:*:*:*:*:*", "matchCriteriaId": "8F962FC7-0616-467F-8CCA-ADEA224B5F7B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr-300wg_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4A53C2B5-A3FD-44CC-A78B-D2124EF37DB4", "versionEndExcluding": "4.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr-300wg:-:*:*:*:*:*:*:*", "matchCriteriaId": "434BC9BE-C5DB-4DAF-8E07-DFE4EEA0D7FE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr524-8c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "54FBE4D4-F31E-4B61-9216-44C8EC2988AB", "versionEndExcluding": "6.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr524-8c:-:*:*:*:*:*:*:*", "matchCriteriaId": "B0E6B7D8-3F9E-43D6-AEFE-DEE3993679C5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr526-8c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "20511D61-FC1D-453E-BDF6-D3FB9951192A", "versionEndExcluding": "6.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr526-8c:-:*:*:*:*:*:*:*", "matchCriteriaId": "67661569-6233-4C74-9C72-88BD14B257FE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr528-6m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "640AC619-B516-46FC-821B-09C4542A3FD6", "versionEndExcluding": "6.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr528-6m:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E048C4A-A414-4C87-A865-4D4218AE32EE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr552-12_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1FB979DB-731B-4693-A9F8-B11ED953717C", "versionEndExcluding": "6.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr552-12:-:*:*:*:*:*:*:*", "matchCriteriaId": "09743616-31C9-4E47-8A4A-B15D76204BE7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cloud_connect_7_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "886D2FE6-B054-4E3B-BACB-F08C0A119A80", "versionStartIncluding": "1.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_cloud_connect_7_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "3B185B70-CAC9-47AC-8639-7A4707C21540", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cloud_connect_7:-:*:*:*:*:*:*:*", "matchCriteriaId": "9FA78457-260C-467B-9785-04B3C8EDF3B3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1242-7_gprs_v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ABEA3BEE-E7AF-4C9A-ADE4-CE7FC1DB7639", "versionStartIncluding": "3.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_cp_1242-7_gprs_v2_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "049460B8-6186-44F9-B41F-284A2EC0B3B4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1242-7_gprs_v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "205482DA-548C-4757-91F0-1599438873BD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_basic_panels_2nd_generation_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "45208694-635A-42AC-B668-8B67C60568B8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_basic_panels_2nd_generation:-:*:*:*:*:*:*:*", "matchCriteriaId": "7D8F8BCE-35CE-492A-8BFE-2C36EA51CE5C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4C147D9-4649-4289-B18B-55BD6E33521A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*", "matchCriteriaId": "F4830E0D-0128-4E5B-AB81-2B238471AE4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "54EFA8B5-8DA1-4547-9E15-BDC265C56006", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels:-:*:*:*:*:*:*:*", "matchCriteriaId": "B1CEB200-E38F-4629-9279-5AF065396678", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_mv500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DE4FA1E6-4C5A-4CDC-AD40-E384C0BCA90D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_mv500:-:*:*:*:*:*:*:*", "matchCriteriaId": "93A5B50E-0316-4189-8F41-54732CFCF63F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1243-1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D254DA1D-C53E-426B-9C69-580CC47CF0AA", "versionStartIncluding": "3.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1243-1:-:*:*:*:*:*:*:*", "matchCriteriaId": "65278BA0-3C81-4D81-9801-D7BE3A1D7680", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_net_cp1243-7_lte_eu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C06A02ED-0BA3-4A2C-AF0C-689B8AEB34B8", "versionStartIncluding": "3.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_net_cp1243-7_lte_eu:-:*:*:*:*:*:*:*", "matchCriteriaId": "209C7B1E-10F6-4215-AF69-CC36192E0FCE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_net_cp1243-7_lte_us_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CF8C00EE-1154-440C-A223-A2CE99CE3126", "versionStartIncluding": "3.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_net_cp1243-7_lte_us:-:*:*:*:*:*:*:*", "matchCriteriaId": "171A9543-E677-422F-8AEA-1BC2D0E53593", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1243-8_irc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DB201DD3-8890-453E-A11E-1E13B3DAB3F9", "versionStartIncluding": "3.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1243-8_irc:-:*:*:*:*:*:*:*", "matchCriteriaId": "350FD323-C876-4C7A-A2E7-4B0660C87F6C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "61E498B1-87FF-454B-8DF0-61D0D3208491", "versionStartIncluding": "2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1542sp-1_irc:-:*:*:*:*:*:*:*", "matchCriteriaId": "C1EE2F10-A7A6-486F-AE5C-53AE25BAF200", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1543-1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "90FB801F-11B5-438C-98A1-E928BFEA2ADB", "versionEndExcluding": "3.0", "versionStartIncluding": "2.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1543-1:-:*:*:*:*:*:*:*", "matchCriteriaId": "F56C2BDC-928E-491A-8E7C-F976B3787C7A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8E4BA1E6-64F7-4B96-8302-134057DAB1BE", "versionStartIncluding": "2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1543sp-1:-:*:*:*:*:*:*:*", "matchCriteriaId": "783B50B8-2FB7-4982-88AA-B4F2AD094796", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1545-1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DCA9544-DD17-4F56-B34C-91A3F37154AF", "versionStartIncluding": "1.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1545-1:-:*:*:*:*:*:*:*", "matchCriteriaId": "1256EB4B-DD8A-4F99-AE69-F74E8F789C63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_pcs_7_telecontrol_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5C25165E-EDE9-42F1-A3B9-0E47630D49CC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_pcs_7_telecontrol:-:*:*:*:*:*:*:*", "matchCriteriaId": "5BF281FB-26E0-43E4-A2B6-4015661368AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_pcs_neo_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6EEACFC9-41B7-4EE0-9427-692363880326", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_pcs_neo:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3CA343-CA2A-4593-930C-158612CE7A55", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_pdm_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7E9AE23E-7DAE-4191-BA4E-A7CD655C4BC8", "versionStartIncluding": "9.1.0.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_pdm:-:*:*:*:*:*:*:*", "matchCriteriaId": "E092B735-42D5-48D5-947B-288C0FA2E180", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_process_historian_opc_ua_server_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D874D636-392A-4750-B976-F411DBCEBA8D", "versionStartIncluding": "2019", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_process_historian_opc_ua_server:-:*:*:*:*:*:*:*", "matchCriteriaId": "14EC9343-7778-40B0-A74D-5C156FF2A229", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf166c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "968FBB4E-5B0B-43D4-B3AD-418028093990", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf166c:-:*:*:*:*:*:*:*", "matchCriteriaId": "391AD485-A49D-43D0-AAE5-1F58B38D4E22", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf185c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5212F097-B65A-4D73-BB6F-49687F8AD980", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf185c:-:*:*:*:*:*:*:*", "matchCriteriaId": "82494B5E-80EE-47ED-B87E-CF8C8907B6FE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf186c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D806113B-57EB-4AA0-9D5E-12E30337A93B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf186c:-:*:*:*:*:*:*:*", "matchCriteriaId": "9B0933EB-82BE-42BB-978B-C9EC2FE1C795", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf186ci_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "53FA50A7-2DF6-454E-8A8E-838C392AB417", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf186ci:-:*:*:*:*:*:*:*", "matchCriteriaId": "1EAEB335-BD22-4CEF-A3EA-9D98A09FEBF0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf188c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7F3D41E9-58B3-4251-8710-A8C4A24ABBD3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf188c:-:*:*:*:*:*:*:*", "matchCriteriaId": "E21F9909-8D80-40BE-81E0-6ED7FE140A3A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf188ci_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FC628CB7-0816-4267-9C5D-954BD0233D2E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf188ci:-:*:*:*:*:*:*:*", "matchCriteriaId": "B0927991-E820-4FC3-9EFE-96E4C9BFCCCD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf360r_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "88E64167-16AA-48D7-BCDC-B15D37FA666D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf360r:-:*:*:*:*:*:*:*", "matchCriteriaId": "63F05227-208B-42C8-8D56-A5D106CAD32F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "47F1294A-1C26-4D43-9C53-D833F2510536", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*", "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4AF60081-D534-44F5-972F-23257F16F372", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*", "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212fc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AEF1726E-B56F-4D39-AFF4-E79A3CA00DE6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212fc:-:*:*:*:*:*:*:*", "matchCriteriaId": "68B3573B-A31E-4489-B2DD-B01B5C1D03CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214_fc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9CC4A9F7-9858-4F95-8097-F8D09DA61314", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214_fc:-:*:*:*:*:*:*:*", "matchCriteriaId": "B640800C-9263-4BEA-9DA5-1323932540BD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4948734A-0AAD-4D28-B7FF-FFBBB9AA39C6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*", "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214_fc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9CC4A9F7-9858-4F95-8097-F8D09DA61314", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214_fc:-:*:*:*:*:*:*:*", "matchCriteriaId": "B640800C-9263-4BEA-9DA5-1323932540BD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215_fc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6EE37798-B068-40E5-BC03-1D8D303E5926", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215_fc:-:*:*:*:*:*:*:*", "matchCriteriaId": "76C7D55C-8D99-4E2F-A254-1BDE2B12A203", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8E0C491C-5C4A-4F1C-ABD4-9502A54AAA78", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*", "matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E7657063-1296-4734-B108-A2FF7A01B07F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*", "matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_mfp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8C477CCD-06C7-4907-8B0C-4FCE7F6DADAD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_mfp:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BC4FA01-8DDB-41E4-B759-7B504F78AEBC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_connect_300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3360ACCE-E735-4E34-B278-0D4460E74CBF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_connect_300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7B854F5B-78C7-41FE-9364-5E71B36342A3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:tim_1531_irc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D2B20D95-C4B3-4D13-A3D8-F22AC42DC059", "versionEndExcluding": "2.2", "versionStartIncluding": "2.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*", "matchCriteriaId": "C1D94BEB-BBFB-4258-9835-87DBBB999239", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_logon:*:*:*:*:*:*:*:*", "matchCriteriaId": "D6F24E40-F3F0-48F3-B3DC-5F98B0564F7A", "versionStartIncluding": "1.6.0.2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_logon:1.5:sp3_update_1:*:*:*:*:*:*", "matchCriteriaId": "423359E5-9C36-4C6B-AB24-B030E6C61D53", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "79EE15DC-74D3-4551-AAD0-EA0CB600DA76", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_telecontrol:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3169FD3-CBA2-417C-95EF-4F8AE9FAB5AD", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinec_nms:1.0:-:*:*:*:*:*:*", "matchCriteriaId": "4ED13FC8-63C0-42C6-A51C-C480C45327C2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinec_nms:1.0:sp1:*:*:*:*:*:*", "matchCriteriaId": "E68FE047-8F53-46B8-82D4-9342B1C8CA55", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinec_pni:-:*:*:*:*:*:*:*", "matchCriteriaId": "1353DC31-FB12-427A-B1B2-9164A4BEE14B", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:-:*:*:*:*:*:*", "matchCriteriaId": "B0A5CC25-A323-4D49-8989-5A417D12D646", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:sp1:*:*:*:*:*:*", "matchCriteriaId": "A690BCD3-6497-43F7-8A51-E033B9121DC8", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:sp2:*:*:*:*:*:*", "matchCriteriaId": "AA375D44-ECC5-4BD3-A3D5-6D2AA68782D5", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:sp2_update1:*:*:*:*:*:*", "matchCriteriaId": "6CD26C73-B61F-424B-91C2-352E2CAE6666", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:sp2_update2:*:*:*:*:*:*", "matchCriteriaId": "DB4EA15F-ECA4-477F-948F-490FC90BC66A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinumerik_opc_ua_server:*:*:*:*:*:*:*:*", "matchCriteriaId": "ABA14E65-214C-431D-A49A-D8FC142D4541", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:tia_administrator:*:*:*:*:*:*:*:*", "matchCriteriaId": "915B09CB-CA0A-445B-89D3-16AE9B08858E", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:sinec_infrastructure_network_services:*:*:*:*:*:*:*:*", "matchCriteriaId": "B0F46497-4AB0-49A7-9453-CC26837BF253", "versionEndExcluding": "1.0.1.1", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*", "matchCriteriaId": "25A3180B-21AF-4010-9DAB-41ADFD2D8031", "versionEndIncluding": "10.12.0", "versionStartIncluding": "10.0.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*", "matchCriteriaId": "43B199B4-D89C-483D-ACAE-6CB2A59EE67C", "versionEndIncluding": "10.24.0", "versionStartIncluding": "10.13.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*", "matchCriteriaId": "564ED5C8-50D7-413A-B88E-E62B6C07336A", "versionEndIncluding": "12.12.0", "versionStartIncluding": "12.0.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*", "matchCriteriaId": "3DEBF7C8-B000-47B9-B597-DC440F2603B3", "versionEndExcluding": "12.22.1", "versionStartIncluding": "12.13.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*", "matchCriteriaId": "428DCD7B-6F66-4F18-B780-5BD80143D482", "versionEndIncluding": "14.14.0", "versionStartIncluding": "14.0.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*", "matchCriteriaId": "380D03F3-6A7E-43A2-B002-FB2521FD3C58", "versionEndExcluding": "14.16.1", "versionStartIncluding": "14.15.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*", "matchCriteriaId": "3ED4D313-F372-4CC1-BE11-6BBA2F0E90E3", "versionEndExcluding": "15.14.0", "versionStartIncluding": "15.0.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)." }, { "lang": "es", "value": "Un servidor OpenSSL TLS puede cometer un fallo si un cliente env\u00eda un mensaje ClientHello de renegociaci\u00f3n dise\u00f1ado maliciosamente.\u0026#xa0;Si una renegociaci\u00f3n de TLSv1.2 ClientHello omite la extensi\u00f3n signature_algorithms (donde estaba presente en el ClientHello inicial), pero incluye una extensi\u00f3n signature_algorithms_cert, se producir\u00e1 una desreferencia del puntero NULL, lo que conllevar\u00e1 un bloqueo y un ataque de denegaci\u00f3n de servicio.\u0026#xa0;Un servidor solo es vulnerable si tiene TLSv1.2 y la renegociaci\u00f3n habilitada (que es la configuraci\u00f3n predeterminada).\u0026#xa0;Los clientes de OpenSSL TLS no est\u00e1n afectados por este problema.\u0026#xa0;Todas las versiones de OpenSSL versi\u00f3n 1.1.1 est\u00e1n afectadas por este problema.\u0026#xa0;Los usuarios de estas versiones deben actualizar a OpenSSL versi\u00f3n 1.1.1k.\u0026#xa0;OpenSSL versi\u00f3n 1.0.2 no est\u00e1 afectado por este problema.\u0026#xa0;Corregido en OpenSSL versi\u00f3n 1.1.1k (Afectadas versiones 1.1.1-1.1.1j)" } ], "id": "CVE-2021-3449", "lastModified": "2024-11-21T06:21:33.050", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 4.3, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 5.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.2, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-25T15:15:13.450", "references": [ { "source": "openssl-security@openssl.org", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1" }, { "source": "openssl-security@openssl.org", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2" }, { "source": "openssl-security@openssl.org", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3" }, { "source": "openssl-security@openssl.org", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf" }, { "source": "openssl-security@openssl.org", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf" }, { "source": "openssl-security@openssl.org", "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356" }, { "source": "openssl-security@openssl.org", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html" }, { "source": "openssl-security@openssl.org", "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://security.gentoo.org/glsa/202103-03" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://security.netapp.com/advisory/ntap-20210326-0006/" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://security.netapp.com/advisory/ntap-20210513-0002/" }, { "source": "openssl-security@openssl.org", "url": "https://security.netapp.com/advisory/ntap-20240621-0006/" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://www.debian.org/security/2021/dsa-4875" }, { "source": "openssl-security@openssl.org", "tags": [ "Vendor Advisory" ], "url": "https://www.openssl.org/news/secadv/20210325.txt" }, { "source": "openssl-security@openssl.org", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://www.oracle.com//security-alerts/cpujul2021.html" }, { "source": "openssl-security@openssl.org", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://www.oracle.com/security-alerts/cpuApr2021.html" }, { "source": "openssl-security@openssl.org", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://www.oracle.com/security-alerts/cpujul2022.html" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://www.oracle.com/security-alerts/cpuoct2021.html" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://www.tenable.com/security/tns-2021-05" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://www.tenable.com/security/tns-2021-06" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://www.tenable.com/security/tns-2021-09" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://www.tenable.com/security/tns-2021-10" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://security.gentoo.org/glsa/202103-03" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://security.netapp.com/advisory/ntap-20210326-0006/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://security.netapp.com/advisory/ntap-20210513-0002/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://security.netapp.com/advisory/ntap-20240621-0006/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://www.debian.org/security/2021/dsa-4875" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.openssl.org/news/secadv/20210325.txt" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://www.oracle.com//security-alerts/cpujul2021.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://www.oracle.com/security-alerts/cpuApr2021.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://www.oracle.com/security-alerts/cpujul2022.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://www.oracle.com/security-alerts/cpuoct2021.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://www.tenable.com/security/tns-2021-05" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://www.tenable.com/security/tns-2021-06" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://www.tenable.com/security/tns-2021-09" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://www.tenable.com/security/tns-2021-10" } ], "sourceIdentifier": "openssl-security@openssl.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-476" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-05-12 14:15
Modified
2024-11-21 05:57
Severity ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | Patch, Vendor Advisory | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Patch, Vendor Advisory | |
productcert@siemens.com | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11 | Third Party Advisory, US Government Resource |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0891D85-C5F4-4CD2-8EFA-84356CE36654", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:-:*:*:*:*:*:*", "matchCriteriaId": "E0005A53-33AD-47AF-B172-CAF423DE213F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update1:*:*:*:*:*:*", "matchCriteriaId": "9696B0D9-5A66-4747-9437-791EAC150DDA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update2:*:*:*:*:*:*", "matchCriteriaId": "F6AC2BA5-1668-4B71-8812-925AC6554F5A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update3:*:*:*:*:*:*", "matchCriteriaId": "047D0868-3DA6-41CF-A6F9-D15668D536FB", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sh150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0F1FAFD2-1E4D-44F3-87A1-8A1380B980BC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sh150:-:*:*:*:*:*:*:*", "matchCriteriaId": "EBC7AA8D-9046-4111-A263-38343997F984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm150i_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D6067521-A21D-4B2A-AFB2-2E033F66B63E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm150i:-:*:*:*:*:*:*:*", "matchCriteriaId": "A44DEAD8-8DB8-41CC-9495-B842BE76EA8F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4BF9157D-0089-4569-9AA1-4DEE94140D25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*", "matchCriteriaId": "BF977545-395A-4C34-BB22-A1047B5B6E85", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4D780400-0AA8-449C-B754-7167CA878D3D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DED7F33B-D475-4232-8683-48554A6729F7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "61CD50EE-6C46-445E-8D46-82768CAAC305", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E032554B-7F51-4482-AF55-743FFB5AC352", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "C6619B0F-7CDC-40A6-89B2-C6067AF45214", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CFFE3048-EEB0-48A0-BED0-8647284B022B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*", "matchCriteriaId": "444DD77F-DB65-4766-A89D-7A679B4CA1E1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33B7E1DE-61B5-4CFC-8640-EB8029CD79D6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "2AE231E2-2B2B-407A-BF7A-9EA35F394229", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "244D9B27-649C-4983-B374-6A8774771AC5", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "A2530BB3-484C-4D24-82F6-15967C8B7B32", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "B5A1FACE-E693-4FDA-944D-0B7F500007B6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D7FB4AA4-1F48-4A25-AA21-5F867A38D23E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "6A673BD0-96B5-48CA-B060-A5D01687A764", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "428B633D-55FF-4DB8-B6DD-5E4EEE52A44C", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:*:*:*:*:*:*:*", "matchCriteriaId": "C33A64DD-22A2-4260-929F-7595CD037823", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "9756D206-E295-4B0C-B159-F9A953342E37", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "82D6FBBF-FD9B-4AFA-B3E1-8E3341948A37", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D43D2191-DBBD-4F7A-B02A-3DCEE46BF904", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "23C6AD3C-C15B-4B67-88D1-236C10BB12CF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FEE4201E-E660-4B3E-91EC-B6A7DC35C189", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "F2D6D924-858A-4542-BCD0-A5631F941039", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "309E4D56-6D39-4E8F-8312-FF178B721392", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "EDB63639-3101-4F60-8193-EF219D99C128", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "4C6C83EE-3DC7-4CB3-8148-CB24A825274E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C6C72B0-17D7-491E-816A-AF855166A90B", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "322584EF-72C0-4032-A02B-FDFFDCCE3FDE", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "C3D5F1BA-2BEA-40A9-8D5B-A612D467C40C", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D14DE5C7-318A-4D08-BB39-1E43F624816A", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "FCDAF23F-9272-4DC5-8D46-37FAC08950CC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "21FB0305-DF87-42FF-BACA-E8255EA74AA9", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "BAA5B299-A45A-4918-AB8F-03A476CEDA17", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "0C29FD64-C041-4269-BC52-8F91321BC247", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "7182C6C0-7DAD-4446-B14E-8EF46FB0CFA9", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "44F6F972-26AF-4A6E-AAD9-B30EBDF52465", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E57B8F3D-5E02-4F0F-9927-9D7C336EBE56", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "845C78A9-AE0F-42B9-9E25-47F541DF5196", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "B23096F5-3546-41D8-BE30-8698BC0C9B42", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D7C5AF13-69FF-444F-B84A-130D7413B307", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "66A17FC6-B6AE-4915-8069-68B41F3C87E2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4C618736-1382-4515-A295-6EC67A2731EA", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "BC0AD5A8-768E-4747-AD89-B924D369565E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "4C2FD1E4-4A01-4BFB-9D2A-5A030C37BD96", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "0AA5C3DC-E67F-4773-B32C-6B362C94BCBE", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "C96C7676-9A0D-46B5-9C49-5F5CE873E2C1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AF42C3EA-84A5-4419-ACBA-6A2F8DB994E2", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "105CCE4B-D8F9-43EA-9089-CEE16A410751", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "7C163E7E-C9E3-4FBD-885A-C2E7FB8B845F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "2CD3DD84-BDAC-4583-BD61-799A5F01A5B4", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "0A4F6758-0B36-4546-A7A7-A4C71B63772E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "12A613F7-4EA4-40FF-931F-EF3C477300DA", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "4B048552-A26D-419E-9EEA-9AFD9457B70B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "0E4E1016-F217-4B75-83D7-F73B1C5A54F9", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "EF2F6982-2C38-4F9B-87A4-AE4404197B7A", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "7745AA84-BC12-4DBD-90A6-DA294EADB7BF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "67CFFD89-1FF2-4F25-A5AB-D6FF8F721132", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "BA4B198A-8288-459D-9586-CD402DE23023", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "AC4FDB83-702A-41D5-B2A5-BDA58B7E13D2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "D972823A-1128-4222-8910-9CA3D38B472F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "A05007D7-3C49-4192-ABDF-FE94BA7FD1D1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "869AD837-79B1-4F76-947B-7DCAD172BDC0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "5C152EB8-A13A-4F16-994A-B6D93A017CC3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "42F38FBA-7D23-4CB2-9A2D-45616E2A2DFB", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "553C9A57-A9D2-47F9-ABA8-042B05DE46C7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "8F5F3B33-2A82-4CDF-A678-76DE13F256D7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "9FE49F2D-B904-4E48-AAFD-669141B570F6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "729F784C-9AC0-4231-A75A-1FA8373FA31F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "FA61AC05-061D-4EE7-BFEF-568F30B9B883", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "374BAF2F-0A32-4F1A-B838-894F9E9D3E0F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C636FCD-78AE-4FA2-95E5-2BBD5A88DA68", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "FDE42199-9152-41A3-BE56-E6789315CF28", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "040F990F-F3C2-46EF-9E40-FD136A19575F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "748BFFBC-56BD-42EC-9B5F-0752D2A70D17", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "B37490B0-A214-4A62-9B67-934048921C1E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "3D7B9F45-5749-4F36-961D-6C5D650ADA07", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "F544593D-368B-4EC1-8448-8C2BA1301216", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A9D26D9F-7081-42B2-8AE4-D04E8429B88D", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "5F902732-9944-4821-BCFB-9937D1301FF6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "B0C061AC-3E64-4667-A0E7-DD58B2E5A014", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "3EECF743-25E8-4483-AA68-B304B38A9290", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "2F557157-AAD6-4601-84C2-2F8574F23683", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "A6BF6644-AF29-4541-9D6A-D07D0CC026F0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "C4FD5396-8094-4DD0-BE7B-0FB6CC6D45F1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A8EC6926-258F-4F5C-88D2-33FE363340DB", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "97E283EF-A950-40E7-91C7-839203A333A5", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "B5B130C2-28B8-464C-981C-B5662B4B4309", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "79407355-4181-4082-A661-C27734D95363", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "8989C7D4-5246-443E-B6E4-8E91462B2E96", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "2BFBC5B2-B00B-4FCD-86B1-A187122035AB", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "B47671A7-A8DB-4DA2-9076-78708C7F1C42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D9CF819-E06C-4EAA-85B3-AC40E039D485", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "4AF727E5-7849-4980-8AA5-7469FD52DF86", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "F36ABC58-C9FE-4F4A-AB81-26D48A79FFD2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "A87DD9FF-9CA3-4AE2-8C86-C30A779E0CE6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "891AF48F-1F4D-4AB8-AE66-FBABDD2CAA76", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "5052CB07-626A-46C4-8966-B8C9325A3BB3", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "6CD47CC7-1414-42C9-94C6-9DBC2C1D9CBE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B28FB484-526A-437E-80E3-B62F54F1BEF6", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "61DFC57F-0359-4B4A-A13C-067B21D3DA7B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "81CE70BF-EBBE-4CD7-999C-25662670EFCB", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "034B7CFC-1234-4914-8C84-7E5BD5FB6E4D", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "221EB3AE-1420-46F8-9EAD-1914503B0435", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "5F9A416C-277F-44B0-A74C-263CB0C37D03", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "FA858127-69A0-4280-80A8-65E0778A90AD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "66FC2264-7DDD-4BEF-9795-AC6A5A00886B", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "D68363A9-D1D5-4E49-98D1-E5F8C324BC22", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "A35D0B0C-695D-4274-8B9E-69ED20B62585", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "FE9C9981-BA54-48BB-A89D-3CA06C7E17C6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "EA400339-123F-494A-8CD8-7232281E7D29", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "C8E943A5-E35C-4CFA-8998-A74385C8740B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "F4D7038E-C705-4FB9-A2D3-82FFC8EE80CC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8E4F0084-91A5-4D7E-971B-9DB979849594", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "36EEF9EB-91EF-4697-A963-7C8F955778EC", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "AA0728BD-F463-456C-A6EB-9FF2FD42AA23", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "7BB0B884-C99A-4854-992F-8588840CC296", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "04BA4916-5693-4915-B4D7-29D97FA02474", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "DC588CE7-1F9D-43EF-A478-C23C8D909685", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "2DE08529-E210-48C1-A7C3-D2D316902A40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "06364800-4C54-4BE4-B4AA-0CF29E4E82AA", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "4FBDFA7B-504A-4F58-967F-15CAFCEB5594", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "4D184A8F-963A-4730-AED4-1994EEA91702", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "16DAC92E-141C-4923-96F5-2620F60E763A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "B3300D8B-E0A1-4CEF-8BE0-AED3F19E9015", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "8104E528-ED7D-451E-8834-057295A7FF49", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "0AF02DF4-7190-4F6C-8F15-37581FFC9B86", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (Todas las versiones anteriores a V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (Todas las versiones anteriores a V16 Update 4), SINAMICS GH150 (Todas las versiones anteriores), SINAMICS GL150 (with option X30) (Todas las versiones anteriores), SINAMICS GM150 (with option X30) (Todas las versiones anteriores), SINAMICS SH150 (Todas las versiones anteriores), SINAMICS SL150 (Todas las versiones anteriores), SINAMICS SM120 (Todas las versiones anteriores), SINAMICS SM150 (Todas las versiones anteriores), SINAMICS SM150i (Todas las versiones anteriores). SmartVNC tiene una vulnerabilidad de acceso a memoria fuera de l\u00edmites en el manejador de dise\u00f1o del dispositivo, representado por un flujo de datos binarios en el lado del cliente, que potencialmente puede resultar en la ejecuci\u00f3n de c\u00f3digo" } ], "id": "CVE-2021-27384", "lastModified": "2024-11-21T05:57:53.230", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-05-12T14:15:11.677", "references": [ { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-788" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-05-12 14:15
Modified
2024-11-21 05:55
Severity ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the client side when sending data from the server, which could result in a Denial-of-Service condition.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Vendor Advisory | |
productcert@siemens.com | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | Third Party Advisory, US Government Resource |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0891D85-C5F4-4CD2-8EFA-84356CE36654", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:-:*:*:*:*:*:*", "matchCriteriaId": "E0005A53-33AD-47AF-B172-CAF423DE213F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update1:*:*:*:*:*:*", "matchCriteriaId": "9696B0D9-5A66-4747-9437-791EAC150DDA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update2:*:*:*:*:*:*", "matchCriteriaId": "F6AC2BA5-1668-4B71-8812-925AC6554F5A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update3:*:*:*:*:*:*", "matchCriteriaId": "047D0868-3DA6-41CF-A6F9-D15668D536FB", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "244D9B27-649C-4983-B374-6A8774771AC5", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "A2530BB3-484C-4D24-82F6-15967C8B7B32", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "B5A1FACE-E693-4FDA-944D-0B7F500007B6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D7FB4AA4-1F48-4A25-AA21-5F867A38D23E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "6A673BD0-96B5-48CA-B060-A5D01687A764", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "428B633D-55FF-4DB8-B6DD-5E4EEE52A44C", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:*:*:*:*:*:*:*", "matchCriteriaId": "C33A64DD-22A2-4260-929F-7595CD037823", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "9756D206-E295-4B0C-B159-F9A953342E37", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "82D6FBBF-FD9B-4AFA-B3E1-8E3341948A37", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D43D2191-DBBD-4F7A-B02A-3DCEE46BF904", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "23C6AD3C-C15B-4B67-88D1-236C10BB12CF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FEE4201E-E660-4B3E-91EC-B6A7DC35C189", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "F2D6D924-858A-4542-BCD0-A5631F941039", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "309E4D56-6D39-4E8F-8312-FF178B721392", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "EDB63639-3101-4F60-8193-EF219D99C128", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "4C6C83EE-3DC7-4CB3-8148-CB24A825274E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C6C72B0-17D7-491E-816A-AF855166A90B", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "322584EF-72C0-4032-A02B-FDFFDCCE3FDE", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "C3D5F1BA-2BEA-40A9-8D5B-A612D467C40C", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D14DE5C7-318A-4D08-BB39-1E43F624816A", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "FCDAF23F-9272-4DC5-8D46-37FAC08950CC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "21FB0305-DF87-42FF-BACA-E8255EA74AA9", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "BAA5B299-A45A-4918-AB8F-03A476CEDA17", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "0C29FD64-C041-4269-BC52-8F91321BC247", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "7182C6C0-7DAD-4446-B14E-8EF46FB0CFA9", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "44F6F972-26AF-4A6E-AAD9-B30EBDF52465", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E57B8F3D-5E02-4F0F-9927-9D7C336EBE56", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "845C78A9-AE0F-42B9-9E25-47F541DF5196", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "B23096F5-3546-41D8-BE30-8698BC0C9B42", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D7C5AF13-69FF-444F-B84A-130D7413B307", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "66A17FC6-B6AE-4915-8069-68B41F3C87E2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4C618736-1382-4515-A295-6EC67A2731EA", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "BC0AD5A8-768E-4747-AD89-B924D369565E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "4C2FD1E4-4A01-4BFB-9D2A-5A030C37BD96", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "0AA5C3DC-E67F-4773-B32C-6B362C94BCBE", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "C96C7676-9A0D-46B5-9C49-5F5CE873E2C1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AF42C3EA-84A5-4419-ACBA-6A2F8DB994E2", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "105CCE4B-D8F9-43EA-9089-CEE16A410751", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "7C163E7E-C9E3-4FBD-885A-C2E7FB8B845F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "2CD3DD84-BDAC-4583-BD61-799A5F01A5B4", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "0A4F6758-0B36-4546-A7A7-A4C71B63772E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "12A613F7-4EA4-40FF-931F-EF3C477300DA", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "4B048552-A26D-419E-9EEA-9AFD9457B70B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "0E4E1016-F217-4B75-83D7-F73B1C5A54F9", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "EF2F6982-2C38-4F9B-87A4-AE4404197B7A", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "7745AA84-BC12-4DBD-90A6-DA294EADB7BF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "67CFFD89-1FF2-4F25-A5AB-D6FF8F721132", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "BA4B198A-8288-459D-9586-CD402DE23023", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "AC4FDB83-702A-41D5-B2A5-BDA58B7E13D2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "D972823A-1128-4222-8910-9CA3D38B472F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "A05007D7-3C49-4192-ABDF-FE94BA7FD1D1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "869AD837-79B1-4F76-947B-7DCAD172BDC0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "5C152EB8-A13A-4F16-994A-B6D93A017CC3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "42F38FBA-7D23-4CB2-9A2D-45616E2A2DFB", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "553C9A57-A9D2-47F9-ABA8-042B05DE46C7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "8F5F3B33-2A82-4CDF-A678-76DE13F256D7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "9FE49F2D-B904-4E48-AAFD-669141B570F6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "729F784C-9AC0-4231-A75A-1FA8373FA31F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "FA61AC05-061D-4EE7-BFEF-568F30B9B883", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "374BAF2F-0A32-4F1A-B838-894F9E9D3E0F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C636FCD-78AE-4FA2-95E5-2BBD5A88DA68", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "FDE42199-9152-41A3-BE56-E6789315CF28", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "040F990F-F3C2-46EF-9E40-FD136A19575F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "748BFFBC-56BD-42EC-9B5F-0752D2A70D17", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "B37490B0-A214-4A62-9B67-934048921C1E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "3D7B9F45-5749-4F36-961D-6C5D650ADA07", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "F544593D-368B-4EC1-8448-8C2BA1301216", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A9D26D9F-7081-42B2-8AE4-D04E8429B88D", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "5F902732-9944-4821-BCFB-9937D1301FF6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "B0C061AC-3E64-4667-A0E7-DD58B2E5A014", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "3EECF743-25E8-4483-AA68-B304B38A9290", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "2F557157-AAD6-4601-84C2-2F8574F23683", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "A6BF6644-AF29-4541-9D6A-D07D0CC026F0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "C4FD5396-8094-4DD0-BE7B-0FB6CC6D45F1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A8EC6926-258F-4F5C-88D2-33FE363340DB", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "97E283EF-A950-40E7-91C7-839203A333A5", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "B5B130C2-28B8-464C-981C-B5662B4B4309", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "79407355-4181-4082-A661-C27734D95363", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "8989C7D4-5246-443E-B6E4-8E91462B2E96", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "2BFBC5B2-B00B-4FCD-86B1-A187122035AB", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "B47671A7-A8DB-4DA2-9076-78708C7F1C42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D9CF819-E06C-4EAA-85B3-AC40E039D485", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "4AF727E5-7849-4980-8AA5-7469FD52DF86", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "F36ABC58-C9FE-4F4A-AB81-26D48A79FFD2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "A87DD9FF-9CA3-4AE2-8C86-C30A779E0CE6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "891AF48F-1F4D-4AB8-AE66-FBABDD2CAA76", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "5052CB07-626A-46C4-8966-B8C9325A3BB3", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "6CD47CC7-1414-42C9-94C6-9DBC2C1D9CBE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B28FB484-526A-437E-80E3-B62F54F1BEF6", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "61DFC57F-0359-4B4A-A13C-067B21D3DA7B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "81CE70BF-EBBE-4CD7-999C-25662670EFCB", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "034B7CFC-1234-4914-8C84-7E5BD5FB6E4D", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "221EB3AE-1420-46F8-9EAD-1914503B0435", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "5F9A416C-277F-44B0-A74C-263CB0C37D03", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "FA858127-69A0-4280-80A8-65E0778A90AD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "66FC2264-7DDD-4BEF-9795-AC6A5A00886B", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "D68363A9-D1D5-4E49-98D1-E5F8C324BC22", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "A35D0B0C-695D-4274-8B9E-69ED20B62585", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "FE9C9981-BA54-48BB-A89D-3CA06C7E17C6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "EA400339-123F-494A-8CD8-7232281E7D29", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "C8E943A5-E35C-4CFA-8998-A74385C8740B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "F4D7038E-C705-4FB9-A2D3-82FFC8EE80CC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8E4F0084-91A5-4D7E-971B-9DB979849594", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "36EEF9EB-91EF-4697-A963-7C8F955778EC", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "AA0728BD-F463-456C-A6EB-9FF2FD42AA23", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "7BB0B884-C99A-4854-992F-8588840CC296", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "04BA4916-5693-4915-B4D7-29D97FA02474", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "DC588CE7-1F9D-43EF-A478-C23C8D909685", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "2DE08529-E210-48C1-A7C3-D2D316902A40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "06364800-4C54-4BE4-B4AA-0CF29E4E82AA", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "4FBDFA7B-504A-4F58-967F-15CAFCEB5594", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "4D184A8F-963A-4730-AED4-1994EEA91702", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "16DAC92E-141C-4923-96F5-2620F60E763A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "B3300D8B-E0A1-4CEF-8BE0-AED3F19E9015", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "8104E528-ED7D-451E-8834-057295A7FF49", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "0AF02DF4-7190-4F6C-8F15-37581FFC9B86", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the client side when sending data from the server, which could result in a Denial-of-Service condition." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (Todas las versiones anteriores a V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (Todas las versiones anteriores a V16 Update 4). SmartVNC tiene una vulnerabilidad de acceso a la memoria fuera de los l\u00edmites que podr\u00eda activarse en el lado del cliente al enviar datos desde el servidor, lo que podr\u00eda dar lugar a una condici\u00f3n de denegaci\u00f3n de servicio" } ], "id": "CVE-2021-25661", "lastModified": "2024-11-21T05:55:14.483", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-05-12T14:15:11.300", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-788" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
cve-2021-25662
Vulnerability from cvelistv5
Published
2021-05-12 13:18
Modified
2024-08-03 20:11
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC client fails to handle an exception properly if the program execution process is modified after sending a packet from the server, which could result in a Denial-of-Service condition.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | x_refsource_MISC | |
https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) |
Version: All versions < V15.1 Update 6 |
||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T20:11:27.535Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4). SmartVNC client fails to handle an exception properly if the program execution process is modified after sending a packet from the server, which could result in a Denial-of-Service condition." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-755", "description": "CWE-755: Improper Handling of Exceptional Conditions", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-10-12T09:49:14", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-25662", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V15", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4). SmartVNC client fails to handle an exception properly if the program execution process is modified after sending a packet from the server, which could result in a Denial-of-Service condition." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-755: Improper Handling of Exceptional Conditions" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-25662", "datePublished": "2021-05-12T13:18:22", "dateReserved": "2021-01-21T00:00:00", "dateUpdated": "2024-08-03T20:11:27.535Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-3449
Vulnerability from cvelistv5
Published
2021-03-25 14:25
Modified
2024-09-17 03:43
Severity ?
EPSS score ?
Summary
An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j).
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T16:53:17.609Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.openssl.org/news/secadv/20210325.txt" }, { "tags": [ "x_transferred" ], "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148" }, { "name": "20210325 Multiple Vulnerabilities in OpenSSL Affecting Cisco Products: March 2021", "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd" }, { "name": "DSA-4875", "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://www.debian.org/security/2021/dsa-4875" }, { "name": "[oss-security] 20210327 OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing", "tags": [ "mailing-list", "x_transferred" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1" }, { "name": "[oss-security] 20210327 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing", "tags": [ "mailing-list", "x_transferred" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2" }, { "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing", "tags": [ "mailing-list", "x_transferred" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3" }, { "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing", "tags": [ "mailing-list", "x_transferred" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4" }, { "name": "GLSA-202103-03", "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://security.gentoo.org/glsa/202103-03" }, { "name": "FEDORA-2021-cbf14ab8f9", "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/" }, { "tags": [ "x_transferred" ], "url": "https://www.oracle.com/security-alerts/cpuApr2021.html" }, { "tags": [ "x_transferred" ], "url": "https://www.tenable.com/security/tns-2021-10" }, { "tags": [ "x_transferred" ], "url": "https://www.tenable.com/security/tns-2021-09" }, { "tags": [ "x_transferred" ], "url": "https://security.netapp.com/advisory/ntap-20210513-0002/" }, { "tags": [ "x_transferred" ], "url": "https://security.netapp.com/advisory/ntap-20210326-0006/" }, { "tags": [ "x_transferred" ], "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc" }, { "tags": [ "x_transferred" ], "url": "https://www.tenable.com/security/tns-2021-06" }, { "tags": [ "x_transferred" ], "url": "https://www.tenable.com/security/tns-2021-05" }, { "tags": [ "x_transferred" ], "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356" }, { "tags": [ "x_transferred" ], "url": "https://www.oracle.com//security-alerts/cpujul2021.html" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf" }, { "tags": [ "x_transferred" ], "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845" }, { "tags": [ "x_transferred" ], "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013" }, { "name": "[debian-lts-announce] 20210831 [SECURITY] [DLA 2751-1] postgresql-9.6 security update", "tags": [ "mailing-list", "x_transferred" ], "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html" }, { "tags": [ "x_transferred" ], "url": "https://www.oracle.com/security-alerts/cpuoct2021.html" }, { "tags": [ "x_transferred" ], "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf" }, { "tags": [ "x_transferred" ], "url": "https://www.oracle.com/security-alerts/cpujul2022.html" }, { "tags": [ "x_transferred" ], "url": "https://security.netapp.com/advisory/ntap-20240621-0006/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "OpenSSL", "vendor": "OpenSSL", "versions": [ { "status": "affected", "version": "Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)" } ] } ], "credits": [ { "lang": "en", "value": "Peter K\u00e4stle (Nokia) and Samuel Sapalski (Nokia)" } ], "datePublic": "2021-03-25T00:00:00", "descriptions": [ { "lang": "en", "value": "An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)." } ], "metrics": [ { "other": { "content": { "lang": "eng", "url": "https://www.openssl.org/policies/secpolicy.html#High", "value": "High" }, "type": "unknown" } } ], "problemTypes": [ { "descriptions": [ { "description": "NULL pointer dereference", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-06-21T19:05:57.096577", "orgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5", "shortName": "openssl" }, "references": [ { "url": "https://www.openssl.org/news/secadv/20210325.txt" }, { "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148" }, { "name": "20210325 Multiple Vulnerabilities in OpenSSL Affecting Cisco Products: March 2021", "tags": [ "vendor-advisory" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd" }, { "name": "DSA-4875", "tags": [ "vendor-advisory" ], "url": "https://www.debian.org/security/2021/dsa-4875" }, { "name": "[oss-security] 20210327 OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing", "tags": [ "mailing-list" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1" }, { "name": "[oss-security] 20210327 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing", "tags": [ "mailing-list" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2" }, { "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing", "tags": [ "mailing-list" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3" }, { "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing", "tags": [ "mailing-list" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4" }, { "name": "GLSA-202103-03", "tags": [ "vendor-advisory" ], "url": "https://security.gentoo.org/glsa/202103-03" }, { "name": "FEDORA-2021-cbf14ab8f9", "tags": [ "vendor-advisory" ], "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/" }, { "url": "https://www.oracle.com/security-alerts/cpuApr2021.html" }, { "url": "https://www.tenable.com/security/tns-2021-10" }, { "url": "https://www.tenable.com/security/tns-2021-09" }, { "url": "https://security.netapp.com/advisory/ntap-20210513-0002/" }, { "url": "https://security.netapp.com/advisory/ntap-20210326-0006/" }, { "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc" }, { "url": "https://www.tenable.com/security/tns-2021-06" }, { "url": "https://www.tenable.com/security/tns-2021-05" }, { "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356" }, { "url": "https://www.oracle.com//security-alerts/cpujul2021.html" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf" }, { "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845" }, { "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013" }, { "name": "[debian-lts-announce] 20210831 [SECURITY] [DLA 2751-1] postgresql-9.6 security update", "tags": [ "mailing-list" ], "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html" }, { "url": "https://www.oracle.com/security-alerts/cpuoct2021.html" }, { "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf" }, { "url": "https://www.oracle.com/security-alerts/cpujul2022.html" }, { "url": "https://security.netapp.com/advisory/ntap-20240621-0006/" } ], "title": "NULL pointer deref in signature_algorithms processing" } }, "cveMetadata": { "assignerOrgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5", "assignerShortName": "openssl", "cveId": "CVE-2021-3449", "datePublished": "2021-03-25T14:25:13.659307Z", "dateReserved": "2021-03-17T00:00:00", "dateUpdated": "2024-09-17T03:43:55.497Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-7592
Vulnerability from cvelistv5
Published
2020-07-14 13:18
Modified
2024-08-04 09:33
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC HMI KTP700F Mobile Arctic (All versions), SIMATIC HMI Mobile Panels 2nd Generation (All versions), SIMATIC WinCC Runtime Advanced (All versions). Unencrypted communication between the configuration software and the respective device could allow an attacker to capture potential plain text communication and have access to sensitive information.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-364335.pdf | x_refsource_MISC | |
https://us-cert.cisa.gov/ics/advisories/icsa-20-196-04 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens AG | SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants) |
Version: All versions |
||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T09:33:19.896Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-364335.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-196-04" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC HMI KTP700F Mobile Arctic", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC HMI Mobile Panels 2nd Generation", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC WinCC Runtime Advanced", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC HMI KTP700F Mobile Arctic (All versions), SIMATIC HMI Mobile Panels 2nd Generation (All versions), SIMATIC WinCC Runtime Advanced (All versions). Unencrypted communication between the configuration software and the respective device could allow an attacker to capture potential plain text communication and have access to sensitive information." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-319", "description": "CWE-319: Cleartext Transmission of Sensitive Information", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-07-16T13:40:34", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-364335.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-196-04" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-7592", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC HMI KTP700F Mobile Arctic", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC HMI Mobile Panels 2nd Generation", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC HMI KTP700F Mobile Arctic (All versions), SIMATIC HMI Mobile Panels 2nd Generation (All versions), SIMATIC WinCC Runtime Advanced (All versions). Unencrypted communication between the configuration software and the respective device could allow an attacker to capture potential plain text communication and have access to sensitive information." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-319: Cleartext Transmission of Sensitive Information" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-364335.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-364335.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-196-04", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-196-04" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-7592", "datePublished": "2020-07-14T13:18:05", "dateReserved": "2020-01-21T00:00:00", "dateUpdated": "2024-08-04T09:33:19.896Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-27386
Vulnerability from cvelistv5
Published
2021-05-12 13:18
Modified
2024-08-03 20:48
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | x_refsource_MISC | |
https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | x_refsource_CONFIRM |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T20:48:16.446Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SINAMICS GH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GL150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GM150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SL150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM120", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150i", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-401", "description": "CWE-401: Missing Release of Memory after Effective Lifetime", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-10-12T09:49:18", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-27386", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V15", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SINAMICS GH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GL150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GM150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SL150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM120", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150i", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-401: Missing Release of Memory after Effective Lifetime" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-27386", "datePublished": "2021-05-12T13:18:23", "dateReserved": "2021-02-18T00:00:00", "dateUpdated": "2024-08-03T20:48:16.446Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-6568
Vulnerability from cvelistv5
Published
2019-04-17 13:40
Modified
2024-08-04 20:23
Severity ?
EPSS score ?
Summary
The webserver of the affected devices contains a vulnerability that may lead to
a denial of service condition. An attacker may cause a denial of service
situation which leads to a restart of the webserver of the affected device.
The security vulnerability could be exploited by an attacker with network
access to the affected systems. Successful exploitation requires no system
privileges and no user interaction. An attacker could use the vulnerability
to compromise availability of the device.
References
Impacted products
Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC CP 1604 |
Version: All versions |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T20:23:22.207Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC CP 1604", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1616", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1 Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 OPC UA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM154-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM154-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM154-8FX PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200S IM151-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200S IM151-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.6" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Upd4" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Upd4" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Upd4" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC IPC DiagMonitor", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF182C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF185C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF186C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF188C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF600R family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RFID 181EIP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.6.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 Software Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 314C-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315T-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317T-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317TF-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 319-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 319F-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-PLCSIM Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0 SP1 UPD1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Basic", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Standard", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX F 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Upd4" } ] }, { "defaultStatus": "unknown", "product": "SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.3" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.6 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.7 SP1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.8 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF6" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V5.1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V5.1 SP1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1 SP1 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.6 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.7 SP1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.8 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF6" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V5.1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V5.1 SP1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1 SP1 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GH150 V4.7 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GH150 V4.8 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2 HF9" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GL150 V4.7 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GL150 V4.8 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2 HF9" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GM150 V4.7 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GM150 V4.8 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2 HF9" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.6 Control Unit (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.7 SP1 Control Unit (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.8 Control Unit (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF6" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V5.1 Control Unit (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V5.1 SP1 Control Unit (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1 SP1 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.6 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.7 SP1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.8 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF6" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V5.1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V5.1 SP1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1 SP1 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S210", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1 SP1 HF8" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SL150 V4.7 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF33" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SL150 V4.8 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SM120 V4.7 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SM120 V4.8 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2 HF10" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SM150 V4.8 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200S IM151-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200S IM151-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET CP 343-1 Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET CP 443-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET CP 443-1 Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 314C-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.16" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 315-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 315F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 317-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 317F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SITOP Manager", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1" } ] }, { "defaultStatus": "unknown", "product": "SITOP PSU8600", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.5" } ] }, { "defaultStatus": "unknown", "product": "SITOP UPS1600 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3" } ] }, { "defaultStatus": "unknown", "product": "TIM 1531 IRC (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] } ], "descriptions": [ { "lang": "en", "value": "The webserver of the affected devices contains a vulnerability that may lead to\r\na denial of service condition. An attacker may cause a denial of service\r\nsituation which leads to a restart of the webserver of the affected device.\r\n\r\nThe security vulnerability could be exploited by an attacker with network\r\naccess to the affected systems. Successful exploitation requires no system\r\nprivileges and no user interaction. An attacker could use the vulnerability\r\nto compromise availability of the device." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125: Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-05-09T11:51:03.049Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-6568", "datePublished": "2019-04-17T13:40:24", "dateReserved": "2019-01-22T00:00:00", "dateUpdated": "2024-08-04T20:23:22.207Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-7580
Vulnerability from cvelistv5
Published
2020-06-10 00:00
Modified
2024-08-04 09:33
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges.
References
Impacted products
Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC Automation Tool |
Version: All versions < V4 SP2 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T09:33:19.492Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf" }, { "tags": [ "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC Automation Tool", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4 SP2" } ] }, { "product": "SIMATIC NET PC Software V14", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1 Update 14" } ] }, { "product": "SIMATIC NET PC Software V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC NET PC Software V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Upd3" } ] }, { "product": "SIMATIC PCS neo", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0 SP1" } ] }, { "product": "SIMATIC ProSave", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V17" } ] }, { "product": "SIMATIC S7-1500 Software Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V21.8" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V13", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V13 SP2 Update 4" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V14", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1 Update 10" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 5" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 2" } ] }, { "product": "SIMATIC STEP 7 V5", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.6 SP2 HF3" } ] }, { "product": "SIMATIC WinCC OA V3.16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.16 P018" } ] }, { "product": "SIMATIC WinCC OA V3.17", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.17 P003" } ] }, { "product": "SIMATIC WinCC Runtime Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 2" } ] }, { "product": "SIMATIC WinCC Runtime Professional V13", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V13 SP2 Update 4" } ] }, { "product": "SIMATIC WinCC Runtime Professional V14", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1 Update 10" } ] }, { "product": "SIMATIC WinCC Runtime Professional V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 5" } ] }, { "product": "SIMATIC WinCC Runtime Professional V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 2" } ] }, { "product": "SIMATIC WinCC V7.4", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.4 SP1 Update 14" } ] }, { "product": "SIMATIC WinCC V7.5", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.5 SP1 Update 3" } ] }, { "product": "SINAMICS STARTER", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.4 HF2" } ] }, { "product": "SINAMICS Startdrive", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V16 Update 3" } ] }, { "product": "SINEC NMS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0 SP2" } ] }, { "product": "SINEMA Server", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP3" } ] }, { "product": "SINUMERIK ONE virtual", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V6.14" } ] }, { "product": "SINUMERIK Operate", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V6.14" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC Automation Tool (All versions \u003c V4 SP2), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions \u003c V16 Upd3), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC ProSave (All versions \u003c V17), SIMATIC S7-1500 Software Controller (All versions \u003c V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions \u003c V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMATIC STEP 7 V5 (All versions \u003c V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions \u003c V3.16 P018), SIMATIC WinCC OA V3.17 (All versions \u003c V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions \u003c V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions \u003c V16 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP1 Update 3), SINAMICS STARTER (All Versions \u003c V5.4 HF2), SINAMICS Startdrive (All Versions \u003c V16 Update 3), SINEC NMS (All versions \u003c V1.0 SP2), SINEMA Server (All versions \u003c V14 SP3), SINUMERIK ONE virtual (All Versions \u003c V6.14), SINUMERIK Operate (All Versions \u003c V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-428", "description": "CWE-428: Unquoted Search Path or Element", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-13T00:00:00", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf" }, { "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-7580", "datePublished": "2020-06-10T00:00:00", "dateReserved": "2020-01-21T00:00:00", "dateUpdated": "2024-08-04T09:33:19.492Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-27385
Vulnerability from cvelistv5
Published
2021-05-12 13:18
Modified
2024-08-03 20:48
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | x_refsource_MISC | |
https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) |
Version: All versions < V15.1 Update 6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T20:48:16.474Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SINAMICS GH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GL150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GM150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SL150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM120", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150i", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-10-12T09:49:17", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-27385", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V15", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SINAMICS GH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GL150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GM150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SL150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM120", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150i", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-400: Uncontrolled Resource Consumption" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-27385", "datePublished": "2021-05-12T13:18:23", "dateReserved": "2021-02-18T00:00:00", "dateUpdated": "2024-08-03T20:48:16.474Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-25661
Vulnerability from cvelistv5
Published
2021-05-12 13:18
Modified
2024-08-03 20:11
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the client side when sending data from the server, which could result in a Denial-of-Service condition.
References
▼ | URL | Tags |
---|---|---|
https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | x_refsource_CONFIRM |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) |
Version: All versions < V15.1 Update 6 |
||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T20:11:27.591Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the client side when sending data from the server, which could result in a Denial-of-Service condition." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-788", "description": "CWE-788: Access of Memory Location After End of Buffer", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-10-12T09:49:12", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-25661", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V15", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the client side when sending data from the server, which could result in a Denial-of-Service condition." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-788: Access of Memory Location After End of Buffer" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-25661", "datePublished": "2021-05-12T13:18:22", "dateReserved": "2021-01-21T00:00:00", "dateUpdated": "2024-08-03T20:11:27.591Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-27384
Vulnerability from cvelistv5
Published
2021-05-12 13:18
Modified
2024-08-03 20:48
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | x_refsource_MISC | |
https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) |
Version: All versions < V15.1 Update 6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T20:48:16.461Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SINAMICS GH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GL150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GM150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SL150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM120", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150i", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-788", "description": "CWE-788: Access of Memory Location After End of Buffer", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-10-12T09:49:16", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-27384", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V15", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SINAMICS GH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GL150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GM150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SL150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM120", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150i", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-788: Access of Memory Location After End of Buffer" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-27384", "datePublished": "2021-05-12T13:18:22", "dateReserved": "2021-02-18T00:00:00", "dateUpdated": "2024-08-03T20:48:16.461Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-6575
Vulnerability from cvelistv5
Published
2019-04-17 13:40
Modified
2024-08-04 20:23
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R family (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions < V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf | x_refsource_MISC |
Impacted products
Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC CP 443-1 OPC UA |
Version: All versions |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T20:23:22.041Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC CP 443-1 OPC UA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.7" } ] }, { "product": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Upd 4" } ] }, { "product": "SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Upd 4" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Upd 4" } ] }, { "product": "SIMATIC IPC DiagMonitor", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1.3" } ] }, { "product": "SIMATIC NET PC Software V13", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC NET PC Software V14", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1 Update 14" } ] }, { "product": "SIMATIC NET PC Software V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC RF188C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.0" } ] }, { "product": "SIMATIC RF600R family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.1" } ] }, { "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.5 \u003c V2.6.1" } ] }, { "product": "SIMATIC S7-1500 Software Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions between V2.5 (including) and V2.7 (excluding)" } ] }, { "product": "SIMATIC WinCC OA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.15 P018" } ] }, { "product": "SIMATIC WinCC Runtime Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Upd 4" } ] }, { "product": "SINEC NMS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0 SP1" } ] }, { "product": "SINEMA Server", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP2" } ] }, { "product": "SINUMERIK OPC UA Server", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] }, { "product": "TeleControl Server Basic", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.1.1" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V2.7), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants) (All versions \u003c V15.1 Upd 4), SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants) (All versions \u003c V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions \u003c V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions \u003c V1.1.0), SIMATIC RF600R family (All versions \u003c V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.5 \u003c V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions \u003c V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Upd 4), SINEC NMS (All versions \u003c V1.0 SP1), SINEMA Server (All versions \u003c V14 SP2), SINUMERIK OPC UA Server (All versions \u003c V2.1), TeleControl Server Basic (All versions \u003c V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-248", "description": "CWE-248: Uncaught Exception", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-08-10T11:16:36", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-6575", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC CP 443-1 OPC UA", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V2.7" } ] } }, { "product_name": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Upd 4" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Upd 4" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Upd 4" } ] } }, { "product_name": "SIMATIC IPC DiagMonitor", "version": { "version_data": [ { "version_value": "All versions \u003c V5.1.3" } ] } }, { "product_name": "SIMATIC NET PC Software V13", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC NET PC Software V14", "version": { "version_data": [ { "version_value": "All versions \u003c V14 SP1 Update 14" } ] } }, { "product_name": "SIMATIC NET PC Software V15", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC RF188C", "version": { "version_data": [ { "version_value": "All versions \u003c V1.1.0" } ] } }, { "product_name": "SIMATIC RF600R family", "version": { "version_data": [ { "version_value": "All versions \u003c V3.2.1" } ] } }, { "product_name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.5 \u003c V2.6.1" } ] } }, { "product_name": "SIMATIC S7-1500 Software Controller", "version": { "version_data": [ { "version_value": "All versions between V2.5 (including) and V2.7 (excluding)" } ] } }, { "product_name": "SIMATIC WinCC OA", "version": { "version_data": [ { "version_value": "All versions \u003c V3.15 P018" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Upd 4" } ] } }, { "product_name": "SINEC NMS", "version": { "version_data": [ { "version_value": "All versions \u003c V1.0 SP1" } ] } }, { "product_name": "SINEMA Server", "version": { "version_data": [ { "version_value": "All versions \u003c V14 SP2" } ] } }, { "product_name": "SINUMERIK OPC UA Server", "version": { "version_data": [ { "version_value": "All versions \u003c V2.1" } ] } }, { "product_name": "TeleControl Server Basic", "version": { "version_data": [ { "version_value": "All versions \u003c V3.1.1" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V2.7), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants) (All versions \u003c V15.1 Upd 4), SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants) (All versions \u003c V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions \u003c V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions \u003c V1.1.0), SIMATIC RF600R family (All versions \u003c V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.5 \u003c V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions \u003c V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Upd 4), SINEC NMS (All versions \u003c V1.0 SP1), SINEMA Server (All versions \u003c V14 SP2), SINUMERIK OPC UA Server (All versions \u003c V2.1), TeleControl Server Basic (All versions \u003c V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-248: Uncaught Exception" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-6575", "datePublished": "2019-04-17T13:40:24", "dateReserved": "2019-01-22T00:00:00", "dateUpdated": "2024-08-04T20:23:22.041Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-25660
Vulnerability from cvelistv5
Published
2021-05-12 13:18
Modified
2024-08-03 20:11
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the server side when sending data from the client, which could result in a Denial-of-Service condition.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) |
Version: All versions < V15.1 Update 6 |
||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T20:11:27.734Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the server side when sending data from the client, which could result in a Denial-of-Service condition." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-788", "description": "CWE-788: Access of Memory Location After End of Buffer", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-10-12T09:49:11", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-25660", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V15", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the server side when sending data from the client, which could result in a Denial-of-Service condition." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-788: Access of Memory Location After End of Buffer" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-25660", "datePublished": "2021-05-12T13:18:22", "dateReserved": "2021-01-21T00:00:00", "dateUpdated": "2024-08-03T20:11:27.734Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-27383
Vulnerability from cvelistv5
Published
2021-05-12 13:18
Modified
2024-08-03 20:48
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | x_refsource_MISC | |
https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) |
Version: All versions < V15.1 Update 6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T20:48:16.589Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SINAMICS GH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GL150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GM150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SL150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM120", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150i", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-770", "description": "CWE-770: Allocation of Resources Without Limits or Throttling", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-10-12T09:49:15", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-27383", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V15", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SINAMICS GH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GL150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GM150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SL150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM120", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150i", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-770: Allocation of Resources Without Limits or Throttling" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-27383", "datePublished": "2021-05-12T13:18:22", "dateReserved": "2021-02-18T00:00:00", "dateUpdated": "2024-08-03T20:48:16.589Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }