Vulnerabilites related to siemens - simatic_wincc_flexible_runtime
Vulnerability from fkie_nvd
Published
2011-09-16 12:35
Modified
2024-11-21 01:30
Severity ?
Summary
Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted packet to TCP port 2308.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_wincc_flexible_runtime | * | |
siemens | simatic_wincc_runtime | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_wincc_flexible_runtime:*:*:*:*:*:*:*:*", "matchCriteriaId": "BA49B1B5-57A3-4405-964F-258B10BAD144", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime:-:*:*:*:advanced:*:*:*", "matchCriteriaId": "1116304B-6CD9-4D44-BC95-B945D82873A4", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted packet to TCP port 2308." }, { "lang": "es", "value": "Desbordamiento de buffer de memoria din\u00e1mica en Siemens WinCC Runtime Advanced Loader, tal como se usa en SIMATIC WinCC flexible Runtime y SIMATIC WinCC (TIA Portal) Runtime Advanced, permite a atacantes remotos provocar una denegaci\u00f3n de servicio (corrupci\u00f3n de memoria) o posiblemente ejecutar c\u00f3digo arbitrario a trav\u00e9s de un paquete modificado al puerto TCP 2308." } ], "id": "CVE-2011-3321", "lastModified": "2024-11-21T01:30:15.513", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ] }, "published": "2011-09-16T12:35:26.450", "references": [ { "source": "cret@cert.org", "url": "http://cache.automation.siemens.com/dnl/jI/jI0NDY5AAAA_29054992_FAQ/Siemens_Security_Advisory_SSA-460621_V1_2.pdf" }, { "source": "cret@cert.org", "tags": [ "Vendor Advisory" ], "url": "http://secunia.com/advisories/46011" }, { "source": "cret@cert.org", "url": "http://support.automation.siemens.com/WW/view/en/29054992" }, { "source": "cret@cert.org", "tags": [ "US Government Resource" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-244-01.pdf" }, { "source": "cret@cert.org", "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69803" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://cache.automation.siemens.com/dnl/jI/jI0NDY5AAAA_29054992_FAQ/Siemens_Security_Advisory_SSA-460621_V1_2.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "http://secunia.com/advisories/46011" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://support.automation.siemens.com/WW/view/en/29054992" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "US Government Resource" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-244-01.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69803" } ], "sourceIdentifier": "cret@cert.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
cve-2011-3321
Vulnerability from cvelistv5
Published
2011-09-15 21:00
Modified
2024-08-06 23:29
Severity ?
EPSS score ?
Summary
Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted packet to TCP port 2308.
References
▼ | URL | Tags |
---|---|---|
http://support.automation.siemens.com/WW/view/en/29054992 | x_refsource_MISC | |
http://cache.automation.siemens.com/dnl/jI/jI0NDY5AAAA_29054992_FAQ/Siemens_Security_Advisory_SSA-460621_V1_2.pdf | x_refsource_CONFIRM | |
https://exchange.xforce.ibmcloud.com/vulnerabilities/69803 | vdb-entry, x_refsource_XF | |
http://secunia.com/advisories/46011 | third-party-advisory, x_refsource_SECUNIA | |
http://www.us-cert.gov/control_systems/pdf/ICSA-11-244-01.pdf | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T23:29:56.827Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://support.automation.siemens.com/WW/view/en/29054992" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://cache.automation.siemens.com/dnl/jI/jI0NDY5AAAA_29054992_FAQ/Siemens_Security_Advisory_SSA-460621_V1_2.pdf" }, { "name": "simatic-wincc-runtime-bo(69803)", "tags": [ "vdb-entry", "x_refsource_XF", "x_transferred" ], "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69803" }, { "name": "46011", "tags": [ "third-party-advisory", "x_refsource_SECUNIA", "x_transferred" ], "url": "http://secunia.com/advisories/46011" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-244-01.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2011-09-06T00:00:00", "descriptions": [ { "lang": "en", "value": "Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted packet to TCP port 2308." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2017-08-28T12:57:01", "orgId": "37e5125f-f79b-445b-8fad-9564f167944b", "shortName": "certcc" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "http://support.automation.siemens.com/WW/view/en/29054992" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://cache.automation.siemens.com/dnl/jI/jI0NDY5AAAA_29054992_FAQ/Siemens_Security_Advisory_SSA-460621_V1_2.pdf" }, { "name": "simatic-wincc-runtime-bo(69803)", "tags": [ "vdb-entry", "x_refsource_XF" ], "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69803" }, { "name": "46011", "tags": [ "third-party-advisory", "x_refsource_SECUNIA" ], "url": "http://secunia.com/advisories/46011" }, { "tags": [ "x_refsource_MISC" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-244-01.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cert@cert.org", "ID": "CVE-2011-3321", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted packet to TCP port 2308." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "http://support.automation.siemens.com/WW/view/en/29054992", "refsource": "MISC", "url": "http://support.automation.siemens.com/WW/view/en/29054992" }, { "name": "http://cache.automation.siemens.com/dnl/jI/jI0NDY5AAAA_29054992_FAQ/Siemens_Security_Advisory_SSA-460621_V1_2.pdf", "refsource": "CONFIRM", "url": "http://cache.automation.siemens.com/dnl/jI/jI0NDY5AAAA_29054992_FAQ/Siemens_Security_Advisory_SSA-460621_V1_2.pdf" }, { "name": "simatic-wincc-runtime-bo(69803)", "refsource": "XF", "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69803" }, { "name": "46011", "refsource": "SECUNIA", "url": "http://secunia.com/advisories/46011" }, { "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-244-01.pdf", "refsource": "MISC", "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-244-01.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b", "assignerShortName": "certcc", "cveId": "CVE-2011-3321", "datePublished": "2011-09-15T21:00:00", "dateReserved": "2011-08-29T00:00:00", "dateUpdated": "2024-08-06T23:29:56.827Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }