Vulnerabilites related to siemens - simatic_tiaportal
Vulnerability from fkie_nvd
Published
2014-11-26 11:59
Modified
2024-11-21 02:19
Severity ?
Summary
The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:7.1:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "BE258BF2-AD82-401C-B020-08A22A549A25",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs7:7.1:sp3:*:*:*:*:*:*",
              "matchCriteriaId": "33FA164B-E269-4140-AC85-2623356AF636",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs7:7.1:sp4:*:*:*:*:*:*",
              "matchCriteriaId": "D62C7959-87D9-42EC-A224-2EE6EF23C1CF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs7:8.0:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "428F68D2-8C1D-4ADE-A6FB-65EC4C426F99",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs7:8.0:sp2:*:*:*:*:*:*",
              "matchCriteriaId": "14193511-1B9B-4319-92AE-BB26F398550C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs7:8.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "172A6A81-C32E-4ACC-AB8C-2014BF3A6901",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_tiaportal:13.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "19C3A00B-A47E-4723-B652-B64FDC5F2601",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_tiaportal:13.0:3:*:*:*:*:*:*",
              "matchCriteriaId": "144DE778-4439-489F-830D-B4742BB11FEB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_tiaportal:13.0:5:*:*:*:*:*:*",
              "matchCriteriaId": "39B75B5E-7979-4E3B-BE94-AE04F17A6F3C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "3CF84FC5-9450-47B7-A4F0-99361C528C00",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.0:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "E8274939-833E-40E1-8D2E-1B28CEA91036",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.0:sp2:*:*:*:*:*:*",
              "matchCriteriaId": "61F46206-F232-4F62-AF4F-E2DCF462AE60",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.0:sp3:*:*:*:*:*:*",
              "matchCriteriaId": "0D0BB2E6-1444-499A-943E-8D19C402F1BD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:1:*:*:*:*:*:*",
              "matchCriteriaId": "2D6E154F-F8A0-4E9D-BC37-E95B1820D2BF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:2:*:*:*:*:*:*",
              "matchCriteriaId": "D6745F96-FA72-457B-AD14-07C4B353310F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:3:*:*:*:*:*:*",
              "matchCriteriaId": "E555D458-59C4-4CBC-95F4-CBA503BCCB24",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:4:*:*:*:*:*:*",
              "matchCriteriaId": "3BEE67FC-D188-4B0C-A837-FC91B406982E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:5:*:*:*:*:*:*",
              "matchCriteriaId": "75121F46-303D-4416-8FBD-1938BDD60AAB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:6:*:*:*:*:*:*",
              "matchCriteriaId": "FF8B251F-399E-4165-B3A6-801775212C5D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:7:*:*:*:*:*:*",
              "matchCriteriaId": "FBE45DD1-630F-448F-90FE-D3CC00266EF1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:8:*:*:*:*:*:*",
              "matchCriteriaId": "CFC7DC1F-B4C5-4116-9B53-706F2B3227DD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.3:1:*:*:*:*:*:*",
              "matchCriteriaId": "B8F27E75-90CD-4C3B-AF0E-90EF338A2D91",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets."
    },
    {
      "lang": "es",
      "value": "El servidor WinCC en Siemens SIMATIC WinCC 7.0 hasta SP3, 7.2 anterior a la actualizaci\u00f3n 9, y 7.3 anterior a la actualizaci\u00f3n 2; SIMATIC PCS 7 7.1 hasta SP4, 8.0 hasta SP2; y 8.1; y TIA Portal 13 anterior a la actualizaci\u00f3n 6 permite a atacantes remotos leer ficheros arbitrarios a trav\u00e9s de paquetes manipulados."
    }
  ],
  "id": "CVE-2014-8552",
  "lastModified": "2024-11-21T02:19:19.387",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2014-11-26T11:59:01.373",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-200"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2014-11-26 11:59
Modified
2024-11-21 02:19
Severity ?
Summary
The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to execute arbitrary code via crafted packets.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:7.1:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "BE258BF2-AD82-401C-B020-08A22A549A25",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs7:7.1:sp3:*:*:*:*:*:*",
              "matchCriteriaId": "33FA164B-E269-4140-AC85-2623356AF636",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs7:7.1:sp4:*:*:*:*:*:*",
              "matchCriteriaId": "D62C7959-87D9-42EC-A224-2EE6EF23C1CF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs7:8.0:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "428F68D2-8C1D-4ADE-A6FB-65EC4C426F99",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs7:8.0:sp2:*:*:*:*:*:*",
              "matchCriteriaId": "14193511-1B9B-4319-92AE-BB26F398550C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs7:8.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "172A6A81-C32E-4ACC-AB8C-2014BF3A6901",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_tiaportal:13.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "19C3A00B-A47E-4723-B652-B64FDC5F2601",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_tiaportal:13.0:3:*:*:*:*:*:*",
              "matchCriteriaId": "144DE778-4439-489F-830D-B4742BB11FEB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_tiaportal:13.0:5:*:*:*:*:*:*",
              "matchCriteriaId": "39B75B5E-7979-4E3B-BE94-AE04F17A6F3C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "3CF84FC5-9450-47B7-A4F0-99361C528C00",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.0:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "E8274939-833E-40E1-8D2E-1B28CEA91036",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.0:sp2:*:*:*:*:*:*",
              "matchCriteriaId": "61F46206-F232-4F62-AF4F-E2DCF462AE60",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.0:sp3:*:*:*:*:*:*",
              "matchCriteriaId": "0D0BB2E6-1444-499A-943E-8D19C402F1BD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:1:*:*:*:*:*:*",
              "matchCriteriaId": "2D6E154F-F8A0-4E9D-BC37-E95B1820D2BF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:2:*:*:*:*:*:*",
              "matchCriteriaId": "D6745F96-FA72-457B-AD14-07C4B353310F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:3:*:*:*:*:*:*",
              "matchCriteriaId": "E555D458-59C4-4CBC-95F4-CBA503BCCB24",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:4:*:*:*:*:*:*",
              "matchCriteriaId": "3BEE67FC-D188-4B0C-A837-FC91B406982E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:5:*:*:*:*:*:*",
              "matchCriteriaId": "75121F46-303D-4416-8FBD-1938BDD60AAB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:6:*:*:*:*:*:*",
              "matchCriteriaId": "FF8B251F-399E-4165-B3A6-801775212C5D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:7:*:*:*:*:*:*",
              "matchCriteriaId": "FBE45DD1-630F-448F-90FE-D3CC00266EF1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:8:*:*:*:*:*:*",
              "matchCriteriaId": "CFC7DC1F-B4C5-4116-9B53-706F2B3227DD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.3:1:*:*:*:*:*:*",
              "matchCriteriaId": "B8F27E75-90CD-4C3B-AF0E-90EF338A2D91",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to execute arbitrary code via crafted packets."
    },
    {
      "lang": "es",
      "value": "El servidor WinCC en Siemens SIMATIC WinCC 7.0 hasta SP3, 7.2 anterior a la actualizaci\u00f3n 9, y 7.3 anterior a la actualizaci\u00f3n 2; SIMATIC PCS 7 7.1 hasta SP4, 8.0 hasta SP2, y 8.1; y TIA Portal 13 anterior a la actualizaci\u00f3n 6 permite a atacantes remotos ejecutar c\u00f3digo arbitrario a trav\u00e9s de paquetes manipulados."
    }
  ],
  "id": "CVE-2014-8551",
  "lastModified": "2024-11-21T02:19:19.247",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2014-11-26T11:59:00.093",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-94"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

cve-2014-8551
Vulnerability from cvelistv5
Published
2014-11-26 11:00
Modified
2024-08-06 13:18
Severity ?
Summary
The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to execute arbitrary code via crafted packets.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T13:18:48.431Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2014-11-21T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to execute arbitrary code via crafted packets."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2014-11-26T06:57:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2014-8551",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to execute arbitrary code via crafted packets."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2014-8551",
    "datePublished": "2014-11-26T11:00:00",
    "dateReserved": "2014-10-30T00:00:00",
    "dateUpdated": "2024-08-06T13:18:48.431Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2014-8552
Vulnerability from cvelistv5
Published
2014-11-26 11:00
Modified
2024-08-06 13:18
Severity ?
Summary
The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T13:18:48.641Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2014-11-21T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2014-11-26T06:57:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2014-8552",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2014-8552",
    "datePublished": "2014-11-26T11:00:00",
    "dateReserved": "2014-10-30T00:00:00",
    "dateUpdated": "2024-08-06T13:18:48.641Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}