Vulnerabilites related to siemens - simatic_tiaportal
Vulnerability from fkie_nvd
Published
2014-11-26 11:59
Modified
2024-11-21 02:19
Severity ?
Summary
The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_pcs_7 | 7.1 | |
siemens | simatic_pcs7 | 7.1 | |
siemens | simatic_pcs7 | 7.1 | |
siemens | simatic_pcs7 | 8.0 | |
siemens | simatic_pcs7 | 8.0 | |
siemens | simatic_pcs7 | 8.1 | |
siemens | simatic_tiaportal | 13.0 | |
siemens | simatic_tiaportal | 13.0 | |
siemens | simatic_tiaportal | 13.0 | |
siemens | simatic_wincc | 7.0 | |
siemens | simatic_wincc | 7.0 | |
siemens | simatic_wincc | 7.0 | |
siemens | simatic_wincc | 7.0 | |
siemens | simatic_wincc | 7.2 | |
siemens | simatic_wincc | 7.2 | |
siemens | simatic_wincc | 7.2 | |
siemens | simatic_wincc | 7.2 | |
siemens | simatic_wincc | 7.2 | |
siemens | simatic_wincc | 7.2 | |
siemens | simatic_wincc | 7.2 | |
siemens | simatic_wincc | 7.2 | |
siemens | simatic_wincc | 7.3 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:7.1:sp1:*:*:*:*:*:*", "matchCriteriaId": "BE258BF2-AD82-401C-B020-08A22A549A25", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs7:7.1:sp3:*:*:*:*:*:*", "matchCriteriaId": "33FA164B-E269-4140-AC85-2623356AF636", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs7:7.1:sp4:*:*:*:*:*:*", "matchCriteriaId": "D62C7959-87D9-42EC-A224-2EE6EF23C1CF", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs7:8.0:sp1:*:*:*:*:*:*", "matchCriteriaId": "428F68D2-8C1D-4ADE-A6FB-65EC4C426F99", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs7:8.0:sp2:*:*:*:*:*:*", "matchCriteriaId": "14193511-1B9B-4319-92AE-BB26F398550C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs7:8.1:*:*:*:*:*:*:*", "matchCriteriaId": "172A6A81-C32E-4ACC-AB8C-2014BF3A6901", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_tiaportal:13.0:*:*:*:*:*:*:*", "matchCriteriaId": "19C3A00B-A47E-4723-B652-B64FDC5F2601", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_tiaportal:13.0:3:*:*:*:*:*:*", "matchCriteriaId": "144DE778-4439-489F-830D-B4742BB11FEB", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_tiaportal:13.0:5:*:*:*:*:*:*", "matchCriteriaId": "39B75B5E-7979-4E3B-BE94-AE04F17A6F3C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.0:*:*:*:*:*:*:*", "matchCriteriaId": "3CF84FC5-9450-47B7-A4F0-99361C528C00", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.0:sp1:*:*:*:*:*:*", "matchCriteriaId": "E8274939-833E-40E1-8D2E-1B28CEA91036", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.0:sp2:*:*:*:*:*:*", "matchCriteriaId": "61F46206-F232-4F62-AF4F-E2DCF462AE60", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.0:sp3:*:*:*:*:*:*", "matchCriteriaId": "0D0BB2E6-1444-499A-943E-8D19C402F1BD", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:1:*:*:*:*:*:*", "matchCriteriaId": "2D6E154F-F8A0-4E9D-BC37-E95B1820D2BF", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:2:*:*:*:*:*:*", "matchCriteriaId": "D6745F96-FA72-457B-AD14-07C4B353310F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:3:*:*:*:*:*:*", "matchCriteriaId": "E555D458-59C4-4CBC-95F4-CBA503BCCB24", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:4:*:*:*:*:*:*", "matchCriteriaId": "3BEE67FC-D188-4B0C-A837-FC91B406982E", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:5:*:*:*:*:*:*", "matchCriteriaId": "75121F46-303D-4416-8FBD-1938BDD60AAB", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:6:*:*:*:*:*:*", "matchCriteriaId": "FF8B251F-399E-4165-B3A6-801775212C5D", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:7:*:*:*:*:*:*", "matchCriteriaId": "FBE45DD1-630F-448F-90FE-D3CC00266EF1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:8:*:*:*:*:*:*", "matchCriteriaId": "CFC7DC1F-B4C5-4116-9B53-706F2B3227DD", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.3:1:*:*:*:*:*:*", "matchCriteriaId": "B8F27E75-90CD-4C3B-AF0E-90EF338A2D91", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets." }, { "lang": "es", "value": "El servidor WinCC en Siemens SIMATIC WinCC 7.0 hasta SP3, 7.2 anterior a la actualizaci\u00f3n 9, y 7.3 anterior a la actualizaci\u00f3n 2; SIMATIC PCS 7 7.1 hasta SP4, 8.0 hasta SP2; y 8.1; y TIA Portal 13 anterior a la actualizaci\u00f3n 6 permite a atacantes remotos leer ficheros arbitrarios a trav\u00e9s de paquetes manipulados." } ], "id": "CVE-2014-8552", "lastModified": "2024-11-21T02:19:19.387", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ] }, "published": "2014-11-26T11:59:01.373", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-200" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2014-11-26 11:59
Modified
2024-11-21 02:19
Severity ?
Summary
The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to execute arbitrary code via crafted packets.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_pcs_7 | 7.1 | |
siemens | simatic_pcs7 | 7.1 | |
siemens | simatic_pcs7 | 7.1 | |
siemens | simatic_pcs7 | 8.0 | |
siemens | simatic_pcs7 | 8.0 | |
siemens | simatic_pcs7 | 8.1 | |
siemens | simatic_tiaportal | 13.0 | |
siemens | simatic_tiaportal | 13.0 | |
siemens | simatic_tiaportal | 13.0 | |
siemens | simatic_wincc | 7.0 | |
siemens | simatic_wincc | 7.0 | |
siemens | simatic_wincc | 7.0 | |
siemens | simatic_wincc | 7.0 | |
siemens | simatic_wincc | 7.2 | |
siemens | simatic_wincc | 7.2 | |
siemens | simatic_wincc | 7.2 | |
siemens | simatic_wincc | 7.2 | |
siemens | simatic_wincc | 7.2 | |
siemens | simatic_wincc | 7.2 | |
siemens | simatic_wincc | 7.2 | |
siemens | simatic_wincc | 7.2 | |
siemens | simatic_wincc | 7.3 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:7.1:sp1:*:*:*:*:*:*", "matchCriteriaId": "BE258BF2-AD82-401C-B020-08A22A549A25", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs7:7.1:sp3:*:*:*:*:*:*", "matchCriteriaId": "33FA164B-E269-4140-AC85-2623356AF636", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs7:7.1:sp4:*:*:*:*:*:*", "matchCriteriaId": "D62C7959-87D9-42EC-A224-2EE6EF23C1CF", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs7:8.0:sp1:*:*:*:*:*:*", "matchCriteriaId": "428F68D2-8C1D-4ADE-A6FB-65EC4C426F99", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs7:8.0:sp2:*:*:*:*:*:*", "matchCriteriaId": "14193511-1B9B-4319-92AE-BB26F398550C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs7:8.1:*:*:*:*:*:*:*", "matchCriteriaId": "172A6A81-C32E-4ACC-AB8C-2014BF3A6901", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_tiaportal:13.0:*:*:*:*:*:*:*", "matchCriteriaId": "19C3A00B-A47E-4723-B652-B64FDC5F2601", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_tiaportal:13.0:3:*:*:*:*:*:*", "matchCriteriaId": "144DE778-4439-489F-830D-B4742BB11FEB", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_tiaportal:13.0:5:*:*:*:*:*:*", "matchCriteriaId": "39B75B5E-7979-4E3B-BE94-AE04F17A6F3C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.0:*:*:*:*:*:*:*", "matchCriteriaId": "3CF84FC5-9450-47B7-A4F0-99361C528C00", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.0:sp1:*:*:*:*:*:*", "matchCriteriaId": "E8274939-833E-40E1-8D2E-1B28CEA91036", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.0:sp2:*:*:*:*:*:*", "matchCriteriaId": "61F46206-F232-4F62-AF4F-E2DCF462AE60", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.0:sp3:*:*:*:*:*:*", "matchCriteriaId": "0D0BB2E6-1444-499A-943E-8D19C402F1BD", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:1:*:*:*:*:*:*", "matchCriteriaId": "2D6E154F-F8A0-4E9D-BC37-E95B1820D2BF", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:2:*:*:*:*:*:*", "matchCriteriaId": "D6745F96-FA72-457B-AD14-07C4B353310F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:3:*:*:*:*:*:*", "matchCriteriaId": "E555D458-59C4-4CBC-95F4-CBA503BCCB24", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:4:*:*:*:*:*:*", "matchCriteriaId": "3BEE67FC-D188-4B0C-A837-FC91B406982E", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:5:*:*:*:*:*:*", "matchCriteriaId": "75121F46-303D-4416-8FBD-1938BDD60AAB", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:6:*:*:*:*:*:*", "matchCriteriaId": "FF8B251F-399E-4165-B3A6-801775212C5D", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:7:*:*:*:*:*:*", "matchCriteriaId": "FBE45DD1-630F-448F-90FE-D3CC00266EF1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:8:*:*:*:*:*:*", "matchCriteriaId": "CFC7DC1F-B4C5-4116-9B53-706F2B3227DD", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.3:1:*:*:*:*:*:*", "matchCriteriaId": "B8F27E75-90CD-4C3B-AF0E-90EF338A2D91", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to execute arbitrary code via crafted packets." }, { "lang": "es", "value": "El servidor WinCC en Siemens SIMATIC WinCC 7.0 hasta SP3, 7.2 anterior a la actualizaci\u00f3n 9, y 7.3 anterior a la actualizaci\u00f3n 2; SIMATIC PCS 7 7.1 hasta SP4, 8.0 hasta SP2, y 8.1; y TIA Portal 13 anterior a la actualizaci\u00f3n 6 permite a atacantes remotos ejecutar c\u00f3digo arbitrario a trav\u00e9s de paquetes manipulados." } ], "id": "CVE-2014-8551", "lastModified": "2024-11-21T02:19:19.247", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ] }, "published": "2014-11-26T11:59:00.093", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-94" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
cve-2014-8551
Vulnerability from cvelistv5
Published
2014-11-26 11:00
Modified
2024-08-06 13:18
Severity ?
EPSS score ?
Summary
The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to execute arbitrary code via crafted packets.
References
▼ | URL | Tags |
---|---|---|
http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf | x_refsource_CONFIRM |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T13:18:48.431Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2014-11-21T00:00:00", "descriptions": [ { "lang": "en", "value": "The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to execute arbitrary code via crafted packets." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2014-11-26T06:57:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2014-8551", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to execute arbitrary code via crafted packets." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf", "refsource": "CONFIRM", "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2014-8551", "datePublished": "2014-11-26T11:00:00", "dateReserved": "2014-10-30T00:00:00", "dateUpdated": "2024-08-06T13:18:48.431Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2014-8552
Vulnerability from cvelistv5
Published
2014-11-26 11:00
Modified
2024-08-06 13:18
Severity ?
EPSS score ?
Summary
The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets.
References
▼ | URL | Tags |
---|---|---|
http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf | x_refsource_CONFIRM |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T13:18:48.641Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2014-11-21T00:00:00", "descriptions": [ { "lang": "en", "value": "The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2014-11-26T06:57:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2014-8552", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf", "refsource": "CONFIRM", "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2014-8552", "datePublished": "2014-11-26T11:00:00", "dateReserved": "2014-10-30T00:00:00", "dateUpdated": "2024-08-06T13:18:48.641Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }