Vulnerabilites related to siemens - simatic_mv500
cve-2020-28400
Vulnerability from cvelistv5
Published
2021-07-13 11:02
Modified
2024-12-10 13:53
Summary
Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial of service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device.
Impacted products
Vendor Product Version
Siemens Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller Version: All versions
Create a notification for this product.
   Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 Version: All versions
Create a notification for this product.
   Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P Version: All versions < V4.7
Create a notification for this product.
   Siemens RUGGEDCOM RM1224 LTE(4G) EU Version: 0   < V6.4
Create a notification for this product.
   Siemens RUGGEDCOM RM1224 LTE(4G) NAM Version: 0   < V6.4
Create a notification for this product.
   Siemens SCALANCE M804PB Version: 0   < V6.4
Create a notification for this product.
   Siemens SCALANCE M812-1 ADSL-Router Version: 0   < V6.4
Create a notification for this product.
   Siemens SCALANCE M812-1 ADSL-Router Version: 0   < V6.4
Create a notification for this product.
   Siemens SCALANCE M816-1 ADSL-Router Version: 0   < V6.4
Create a notification for this product.
   Siemens SCALANCE M816-1 ADSL-Router Version: 0   < V6.4
Create a notification for this product.
   Siemens SCALANCE M826-2 SHDSL-Router Version: 0   < V6.4
Create a notification for this product.
   Siemens SCALANCE M874-2 Version: 0   < V6.4
Create a notification for this product.
   Siemens SCALANCE M874-3 Version: 0   < V6.4
Create a notification for this product.
   Siemens SCALANCE M874-3 3G-Router (CN) Version: 0   < V6.4
Create a notification for this product.
   Siemens SCALANCE M876-3 Version: 0   < V6.4
Create a notification for this product.
   Siemens SCALANCE M876-3 (ROK) Version: 0   < V6.4
Create a notification for this product.
   Siemens SCALANCE M876-4 Version: 0   < V6.4
Create a notification for this product.
   Siemens SCALANCE M876-4 (EU) Version: 0   < V6.4
Create a notification for this product.
   Siemens SCALANCE M876-4 (NAM) Version: 0   < V6.4
Create a notification for this product.
   Siemens SCALANCE MUM853-1 (A1) Version: 0   < V6.4
Create a notification for this product.
   Siemens SCALANCE MUM853-1 (B1) Version: 0   < V6.4
Create a notification for this product.
   Siemens SCALANCE MUM853-1 (EU) Version: 0   < V6.4
Create a notification for this product.
   Siemens SCALANCE MUM856-1 (A1) Version: 0   < V6.4
Create a notification for this product.
   Siemens SCALANCE MUM856-1 (B1) Version: 0   < V6.4
Create a notification for this product.
   Siemens SCALANCE MUM856-1 (CN) Version: 0   < V6.4
Create a notification for this product.
   Siemens SCALANCE MUM856-1 (EU) Version: 0   < V6.4
Create a notification for this product.
   Siemens SCALANCE MUM856-1 (RoW) Version: 0   < V6.4
Create a notification for this product.
   Siemens SCALANCE S615 EEC LAN-Router Version: 0   < V6.4
Create a notification for this product.
   Siemens SCALANCE S615 LAN-Router Version: 0   < V6.4
Create a notification for this product.
   Siemens SCALANCE W1748-1 M12 Version: All versions < V3.0.0
Create a notification for this product.
   Siemens SCALANCE W1748-1 M12 Version: All versions < V3.0.0
Create a notification for this product.
   Siemens SCALANCE W1788-1 M12 Version: All versions < V3.0.0
Create a notification for this product.
   Siemens SCALANCE W1788-2 EEC M12 Version: All versions < V3.0.0
Create a notification for this product.
   Siemens SCALANCE W1788-2 M12 Version: All versions < V3.0.0
Create a notification for this product.
   Siemens SCALANCE W1788-2IA M12 Version: All versions < V3.0.0
Create a notification for this product.
   Siemens SCALANCE W721-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W721-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W722-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W722-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W722-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W734-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W734-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W734-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W734-1 RJ45 (USA) Version: All versions
Create a notification for this product.
   Siemens SCALANCE W738-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W738-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W748-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W748-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W748-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W748-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W761-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W761-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W774-1 M12 EEC Version: All versions
Create a notification for this product.
   Siemens SCALANCE W774-1 M12 EEC Version: All versions
Create a notification for this product.
   Siemens SCALANCE W774-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W774-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W774-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W774-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W774-1 RJ45 (USA) Version: All versions
Create a notification for this product.
   Siemens SCALANCE W778-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W778-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W778-1 M12 EEC Version: All versions
Create a notification for this product.
   Siemens SCALANCE W778-1 M12 EEC (USA) Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-2 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-2 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-2 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-2 SFP Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-2 SFP Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-2IA RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-2IA RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-2 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-2 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-2 M12 EEC Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-2 M12 EEC Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-2 M12 EEC Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-2 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-2 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-2 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE X200-4P IRT Version: All Versions < V5.5.0
Create a notification for this product.
   Siemens SCALANCE X201-3P IRT Version: All Versions < V5.5.0
Create a notification for this product.
   Siemens SCALANCE X201-3P IRT PRO Version: All Versions < V5.5.0
Create a notification for this product.
   Siemens SCALANCE X202-2IRT Version: All Versions < V5.5.0
Create a notification for this product.
   Siemens SCALANCE X202-2P IRT Version: All Versions < V5.5.0
Create a notification for this product.
   Siemens SCALANCE X202-2P IRT PRO Version: All Versions < V5.5.0
Create a notification for this product.
   Siemens SCALANCE X204-2 Version: 0   < V5.2.5
Create a notification for this product.
   Siemens SCALANCE X204-2FM Version: 0   < V5.2.5
Create a notification for this product.
   Siemens SCALANCE X204-2LD Version: 0   < V5.2.5
Create a notification for this product.
   Siemens SCALANCE X204-2LD TS Version: 0   < V5.2.5
Create a notification for this product.
   Siemens SCALANCE X204-2TS Version: 0   < V5.2.5
Create a notification for this product.
   Siemens SCALANCE X204IRT Version: All Versions < V5.5.0
Create a notification for this product.
   Siemens SCALANCE X204IRT PRO Version: All Versions < V5.5.0
Create a notification for this product.
   Siemens SCALANCE X206-1 Version: 0   < V5.2.5
Create a notification for this product.
   Siemens SCALANCE X206-1LD Version: 0   < V5.2.5
Create a notification for this product.
   Siemens SCALANCE X208 Version: 0   < V5.2.5
Create a notification for this product.
   Siemens SCALANCE X208PRO Version: 0   < V5.2.5
Create a notification for this product.
   Siemens SCALANCE X212-2 Version: 0   < V5.2.5
Create a notification for this product.
   Siemens SCALANCE X212-2LD Version: 0   < V5.2.5
Create a notification for this product.
   Siemens SCALANCE X216 Version: 0   < V5.2.5
Create a notification for this product.
   Siemens SCALANCE X224 Version: 0   < V5.2.5
Create a notification for this product.
   Siemens SCALANCE X302-7 EEC (230V, coated) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X302-7 EEC (230V) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X302-7 EEC (24V, coated) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X302-7 EEC (24V) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X302-7 EEC (2x 230V, coated) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X302-7 EEC (2x 230V) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X302-7 EEC (2x 24V, coated) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X302-7 EEC (2x 24V) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X304-2FE Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X306-1LD FE Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X307-2 EEC (230V, coated) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X307-2 EEC (230V) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X307-2 EEC (24V, coated) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X307-2 EEC (24V) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X307-2 EEC (2x 230V, coated) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X307-2 EEC (2x 230V) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X307-2 EEC (2x 24V, coated) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X307-2 EEC (2x 24V) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X307-3 Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X307-3 Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X307-3LD Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X307-3LD Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X308-2 Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X308-2 Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X308-2LD Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X308-2LD Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X308-2LH Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X308-2LH Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X308-2LH+ Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X308-2LH+ Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X308-2M Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X308-2M Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X308-2M PoE Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X308-2M PoE Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X308-2M TS Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X308-2M TS Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X310 Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X310 Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X310FE Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X310FE Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X320-1 FE Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X320-1-2LD FE Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE X408-2 Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE XB205-3 (SC, PN) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XB205-3 (ST, E/IP) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XB205-3 (ST, E/IP) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XB205-3 (ST, PN) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XB205-3LD (SC, E/IP) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XB205-3LD (SC, PN) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XB208 (E/IP) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XB208 (PN) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XB213-3 (SC, E/IP) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XB213-3 (SC, PN) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XB213-3 (ST, E/IP) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XB213-3 (ST, PN) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XB213-3LD (SC, E/IP) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XB213-3LD (SC, PN) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XB216 (E/IP) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XB216 (PN) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XC206-2 (SC) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XC206-2 (ST/BFOC) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XC206-2G PoE Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XC206-2G PoE (54 V DC) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XC206-2G PoE EEC (54 V DC) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XC206-2SFP Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XC206-2SFP EEC Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XC206-2SFP G Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XC206-2SFP G (EIP DEF.) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XC206-2SFP G EEC Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XC208 Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XC208EEC Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XC208G Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XC208G (EIP def.) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XC208G EEC Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XC208G PoE Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XC208G PoE (54 V DC) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XC216 Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XC216-3G PoE Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XC216-3G PoE (54 V DC) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XC216-4C Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XC216-4C G Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XC216-4C G (EIP Def.) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XC216-4C G EEC Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XC216EEC Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XC224 Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XC224-4C G Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XC224-4C G (EIP Def.) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XC224-4C G EEC Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XF201-3P IRT Version: All Versions < V5.5.0
Create a notification for this product.
   Siemens SCALANCE XF202-2P IRT Version: All Versions < V5.5.0
Create a notification for this product.
   Siemens SCALANCE XF204 Version: 0   < V5.2.5
Create a notification for this product.
   Siemens SCALANCE XF204 Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XF204 DNA Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XF204-2 Version: 0   < V5.2.5
Create a notification for this product.
   Siemens SCALANCE XF204-2BA Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XF204-2BA DNA Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XF204-2BA IRT Version: All Versions < V5.5.0
Create a notification for this product.
   Siemens SCALANCE XF204IRT Version: All Versions < V5.5.0
Create a notification for this product.
   Siemens SCALANCE XF206-1 Version: 0   < V5.2.5
Create a notification for this product.
   Siemens SCALANCE XF208 Version: 0   < V5.2.5
Create a notification for this product.
   Siemens SCALANCE XM408-4C Version: 0   < V6.3.1
Create a notification for this product.
   Siemens SCALANCE XM408-4C (L3 int.) Version: 0   < V6.3.1
Create a notification for this product.
   Siemens SCALANCE XM408-8C Version: 0   < V6.3.1
Create a notification for this product.
   Siemens SCALANCE XM408-8C (L3 int.) Version: 0   < V6.3.1
Create a notification for this product.
   Siemens SCALANCE XM416-4C Version: 0   < V6.3.1
Create a notification for this product.
   Siemens SCALANCE XM416-4C (L3 int.) Version: 0   < V6.3.1
Create a notification for this product.
   Siemens SCALANCE XP208 Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XP208 (Ethernet/IP) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XP208EEC Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XP208PoE EEC Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XP216 Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XP216 (Ethernet/IP) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XP216EEC Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XP216POE EEC Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XR324-12M (230V, ports on front) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE XR324-12M (230V, ports on front) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE XR324-12M (230V, ports on rear) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE XR324-12M (230V, ports on rear) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE XR324-12M (24V, ports on front) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE XR324-12M (24V, ports on front) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE XR324-12M (24V, ports on rear) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE XR324-12M (24V, ports on rear) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE XR324-12M TS (24V) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE XR324-12M TS (24V) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE XR324-4M EEC (24V, ports on front) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE XR324-4M EEC (24V, ports on front) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE XR324-4M EEC (24V, ports on rear) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE XR324-4M EEC (24V, ports on rear) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE XR324-4M EEC (2x 24V, ports on front) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE XR324-4M EEC (2x 24V, ports on front) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE XR324-4M EEC (2x 24V, ports on rear) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE XR324-4M EEC (2x 24V, ports on rear) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE XR324-4M PoE (230V, ports on front) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE XR324-4M PoE (230V, ports on rear) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE XR324-4M PoE (24V, ports on front) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE XR324-4M PoE (24V, ports on rear) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE XR324-4M PoE TS (24V, ports on front) Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SCALANCE XR324WG (24 x FE, AC 230V) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XR324WG (24 X FE, DC 24V) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XR326-2C PoE WG Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XR326-2C PoE WG (without UL) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (28xGE, AC 230V) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (28xGE, DC 24V) Version: 0   < V4.3
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 1x230V Version: 0   < V6.3.1
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 1x230V (L3 int.) Version: 0   < V6.3.1
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 24V Version: 0   < V6.3.1
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 24V (L3 int.) Version: 0   < V6.3.1
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 2x230V Version: 0   < V6.3.1
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 2x230V (L3 int.) Version: 0   < V6.3.1
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 1x230V Version: 0   < V6.3.1
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 1x230V (L3 int.) Version: 0   < V6.3.1
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 24V Version: 0   < V6.3.1
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 24V (L3 int.) Version: 0   < V6.3.1
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 2x230V Version: 0   < V6.3.1
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 2x230V (L3 int.) Version: 0   < V6.3.1
Create a notification for this product.
   Siemens SCALANCE XR528-6M Version: 0   < V6.3.1
Create a notification for this product.
   Siemens SCALANCE XR528-6M (2HR2, L3 int.) Version: 0   < V6.3.1
Create a notification for this product.
   Siemens SCALANCE XR528-6M (2HR2) Version: 0   < V6.3.1
Create a notification for this product.
   Siemens SCALANCE XR528-6M (L3 int.) Version: 0   < V6.3.1
Create a notification for this product.
   Siemens SCALANCE XR552-12M Version: 0   < V6.3.1
Create a notification for this product.
   Siemens SCALANCE XR552-12M (2HR2, L3 int.) Version: 0   < V6.3.1
Create a notification for this product.
   Siemens SCALANCE XR552-12M (2HR2) Version: 0   < V6.3.1
Create a notification for this product.
   Siemens SCALANCE XR552-12M (2HR2) Version: 0   < V6.3.1
Create a notification for this product.
   Siemens SIMATIC CFU DIQ Version: 0   < V2.0.0
Create a notification for this product.
   Siemens SIMATIC CFU PA Version: 0   < V2.0.0
Create a notification for this product.
   Siemens SIMATIC CM 1542-1 Version: All versions < V3.0
Create a notification for this product.
   Siemens SIMATIC CP 1604 Version: All Versions >= V2.7
Create a notification for this product.
   Siemens SIMATIC CP 1616 Version: All Versions >= V2.7
Create a notification for this product.
   Siemens SIMATIC CP 1626 Version: All versions
Create a notification for this product.
   Siemens SIMATIC IE/PB-LINK Version: V3   < *
Create a notification for this product.
   Siemens SIMATIC MV540 H Version: All versions < V3.0
Create a notification for this product.
   Siemens SIMATIC MV540 S Version: All versions < V3.0
Create a notification for this product.
   Siemens SIMATIC MV550 H Version: All versions < V3.0
Create a notification for this product.
   Siemens SIMATIC MV550 S Version: All versions < V3.0
Create a notification for this product.
   Siemens SIMATIC MV560 U Version: All versions < V3.0
Create a notification for this product.
   Siemens SIMATIC MV560 X Version: All versions < V3.0
Create a notification for this product.
   Siemens SIMATIC NET DK-16xx PN IO Version: All Versions >= V2.7
Create a notification for this product.
   Siemens SIMATIC Power Line Booster PLB, Base Module Version: All versions
Create a notification for this product.
   Siemens SIMATIC PROFINET Driver Version: All versions < V2.3
Create a notification for this product.
   Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) Version: All Versions < V4.5
Create a notification for this product.
   Siemens SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants) Version: All versions < V1.1.3
Create a notification for this product.
   Siemens SIMOCODE pro V PROFINET (incl. SIPLUS variants) Version: All versions < V2.1.3
Create a notification for this product.
   Siemens SIPLUS NET SCALANCE X308-2 Version: 0   < V4.1.4
Create a notification for this product.
   Siemens SIPLUS NET SCALANCE XC206-2 Version: 0   < V4.3
Create a notification for this product.
   Siemens SIPLUS NET SCALANCE XC206-2SFP Version: 0   < V4.3
Create a notification for this product.
   Siemens SIPLUS NET SCALANCE XC208 Version: 0   < V4.3
Create a notification for this product.
   Siemens SIPLUS NET SCALANCE XC216-4C Version: 0   < V4.3
Create a notification for this product.
   Siemens SOFTNET-IE PNIO Version: All versions
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:seimens:scalance_m812-1_adsl-router_annex_b:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m812-1_adsl-router_annex_b",
            "vendor": "seimens",
            "versions": [
              {
                "status": "affected",
                "version": "0"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:development_evaluation_kits_for_profinet_io_dk_standard_ethernet_controller:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "development_evaluation_kits_for_profinet_io_dk_standard_ethernet_controller",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:development_evaluation_kits_for_profinet_io_ek_ertec_200:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "development_evaluation_kits_for_profinet_io_ek_ertec_200",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:development_evaluation_kits_for_profinet_io_ek_ertec_200p:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "development_evaluation_kits_for_profinet_io_ek_ertec_200p",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v4.7",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:ruggedcom_rm1224:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ruggedcom_rm1224",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:scalance_m804pb:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m804pb",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:seimens:scalance_m812-1_adsl-router_annex_a:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m812-1_adsl-router_annex_a",
            "vendor": "seimens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:seimens:scalance_m812-1_adsl-router_annex_b:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m812-1_adsl-router_annex_b",
            "vendor": "seimens",
            "versions": [
              {
                "lessThan": "6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_m816_1_adsl_router_annex_a:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m816_1_adsl_router_annex_a",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_m816-1_adsl-router_annex_b:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m816-1_adsl-router_annex_b",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_m826-2_shdsl-router:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m826-2_shdsl-router",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalence_m874_2:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalence_m874_2",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalence_m874_3:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalence_m874_3",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_m876_3_evdo:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m876_3_evdo",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_m876_3_rok:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m876_3_rok",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_m876_4_eu:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m876_4_eu",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_m876_4_nam:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m876_4_nam",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_s615",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_w700_ieee_802.11n_family:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_w700_ieee_802.11n_family",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_w1748_1_m12:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_w1748_1_m12",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.0.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_w1788_1_m12:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_w1788_1_m12",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.0.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_w1788_2_eec_m12:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_w1788_2_eec_m12",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.0.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_w1788_2_m12:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_w1788_2_m12",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.0.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_w1788_2ia_m12:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_w1788_2ia_m12",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.0.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_x200_4p_irt:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_x200_4p_irt",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.5.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_x201_3p_irt:0.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_x201_3p_irt",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.5.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_x201_3p_irt_pro:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_x201_3p_irt_pro",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.5.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalancce_x202_2p_irt:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalancce_x202_2p_irt",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.5.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalence_202_2p_irt_pro:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalence_202_2p_irt_pro",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.5.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalancce_x204_2:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalancce_x204_2",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.25",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalence_x204_2fm:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalence_x204_2fm",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.25",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalence_x204_2ld:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalence_x204_2ld",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.25",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalence_x204_2ld_ts:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalence_x204_2ld_ts",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.25",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalence_x204_2ts:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalence_x204_2ts",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.25",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2020-28400",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-13T18:59:11.953107Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-24T18:07:44.485Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:33:59.218Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-599968.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) EU",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) NAM",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M804PB",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M826-2 SHDSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-3 3G-Router (CN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (ROK)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (NAM)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM853-1 (A1)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM853-1 (B1)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM853-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (A1)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (B1)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (CN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (RoW)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615 EEC LAN-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615 LAN-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2 EEC M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2IA M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W721-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W721-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W738-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W738-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W761-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W761-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12 EEC (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2IA RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2IA RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X200-4P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X201-3P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X201-3P IRT PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X202-2IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X202-2P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X202-2P IRT PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2FM",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2LD TS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2TS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204IRT PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X206-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X206-1LD",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X208",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X208PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X212-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X212-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X216",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X224",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X304-2FE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X306-1LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X320-1 FE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X320-1-2LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X408-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (SC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (ST/BFOC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G (EIP DEF.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G (EIP def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF201-3P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF202-2P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204 DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF206-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF208",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-4C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-8C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-8C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM416-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM416-4C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208PoE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216POE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M PoE (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M PoE (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 x FE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 X FE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG (without UL)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 1x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 24V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 24V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 2x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 1x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 24V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 24V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 2x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (2HR2, L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2, L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CFU DIQ",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CFU PA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CM 1542-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1604",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003e= V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1616",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003e= V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1626",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IE/PB-LINK",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV540 H",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV540 S",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV550 H",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV550 S",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV560 U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV560 X",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC NET DK-16xx PN IO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003e= V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Power Line Booster PLB, Base Module",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PROFINET Driver",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V4.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SOFTNET-IE PNIO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial of service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-770",
              "description": "CWE-770: Allocation of Resources Without Limits or Throttling",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-12-10T13:53:22.763Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-599968.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-28400",
    "datePublished": "2021-07-13T11:02:49",
    "dateReserved": "2020-11-10T00:00:00",
    "dateUpdated": "2024-12-10T13:53:22.763Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-3449
Vulnerability from cvelistv5
Published
2021-03-25 14:25
Modified
2024-09-17 03:43
Severity ?
Summary
An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j).
References
https://www.openssl.org/news/secadv/20210325.txt
https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148
https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJdvendor-advisory
https://www.debian.org/security/2021/dsa-4875vendor-advisory
http://www.openwall.com/lists/oss-security/2021/03/27/1mailing-list
http://www.openwall.com/lists/oss-security/2021/03/27/2mailing-list
http://www.openwall.com/lists/oss-security/2021/03/28/3mailing-list
http://www.openwall.com/lists/oss-security/2021/03/28/4mailing-list
https://security.gentoo.org/glsa/202103-03vendor-advisory
https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/vendor-advisory
https://www.oracle.com/security-alerts/cpuApr2021.html
https://www.tenable.com/security/tns-2021-10
https://www.tenable.com/security/tns-2021-09
https://security.netapp.com/advisory/ntap-20210513-0002/
https://security.netapp.com/advisory/ntap-20210326-0006/
https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc
https://www.tenable.com/security/tns-2021-06
https://www.tenable.com/security/tns-2021-05
https://kc.mcafee.com/corporate/index?page=content&id=SB10356
https://www.oracle.com//security-alerts/cpujul2021.html
https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf
https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845
https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013
https://lists.debian.org/debian-lts-announce/2021/08/msg00029.htmlmailing-list
https://www.oracle.com/security-alerts/cpuoct2021.html
https://www.oracle.com/security-alerts/cpuapr2022.html
https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf
https://www.oracle.com/security-alerts/cpujul2022.html
https://security.netapp.com/advisory/ntap-20240621-0006/
Impacted products
Vendor Product Version
OpenSSL OpenSSL Version: Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T16:53:17.609Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.openssl.org/news/secadv/20210325.txt"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148"
          },
          {
            "name": "20210325 Multiple Vulnerabilities in OpenSSL Affecting Cisco Products: March 2021",
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd"
          },
          {
            "name": "DSA-4875",
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.debian.org/security/2021/dsa-4875"
          },
          {
            "name": "[oss-security] 20210327 OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
            "tags": [
              "mailing-list",
              "x_transferred"
            ],
            "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1"
          },
          {
            "name": "[oss-security] 20210327 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
            "tags": [
              "mailing-list",
              "x_transferred"
            ],
            "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2"
          },
          {
            "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
            "tags": [
              "mailing-list",
              "x_transferred"
            ],
            "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3"
          },
          {
            "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
            "tags": [
              "mailing-list",
              "x_transferred"
            ],
            "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4"
          },
          {
            "name": "GLSA-202103-03",
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://security.gentoo.org/glsa/202103-03"
          },
          {
            "name": "FEDORA-2021-cbf14ab8f9",
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.tenable.com/security/tns-2021-10"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.tenable.com/security/tns-2021-09"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20210513-0002/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20210326-0006/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.tenable.com/security/tns-2021-06"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.tenable.com/security/tns-2021-05"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.oracle.com//security-alerts/cpujul2021.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013"
          },
          {
            "name": "[debian-lts-announce] 20210831 [SECURITY] [DLA 2751-1] postgresql-9.6 security update",
            "tags": [
              "mailing-list",
              "x_transferred"
            ],
            "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "OpenSSL",
          "vendor": "OpenSSL",
          "versions": [
            {
              "status": "affected",
              "version": "Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Peter K\u00e4stle (Nokia) and Samuel Sapalski (Nokia)"
        }
      ],
      "datePublic": "2021-03-25T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)."
        }
      ],
      "metrics": [
        {
          "other": {
            "content": {
              "lang": "eng",
              "url": "https://www.openssl.org/policies/secpolicy.html#High",
              "value": "High"
            },
            "type": "unknown"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "NULL pointer dereference",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-21T19:05:57.096577",
        "orgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5",
        "shortName": "openssl"
      },
      "references": [
        {
          "url": "https://www.openssl.org/news/secadv/20210325.txt"
        },
        {
          "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148"
        },
        {
          "name": "20210325 Multiple Vulnerabilities in OpenSSL Affecting Cisco Products: March 2021",
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd"
        },
        {
          "name": "DSA-4875",
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.debian.org/security/2021/dsa-4875"
        },
        {
          "name": "[oss-security] 20210327 OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
          "tags": [
            "mailing-list"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1"
        },
        {
          "name": "[oss-security] 20210327 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
          "tags": [
            "mailing-list"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2"
        },
        {
          "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
          "tags": [
            "mailing-list"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3"
        },
        {
          "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
          "tags": [
            "mailing-list"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4"
        },
        {
          "name": "GLSA-202103-03",
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://security.gentoo.org/glsa/202103-03"
        },
        {
          "name": "FEDORA-2021-cbf14ab8f9",
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/"
        },
        {
          "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
        },
        {
          "url": "https://www.tenable.com/security/tns-2021-10"
        },
        {
          "url": "https://www.tenable.com/security/tns-2021-09"
        },
        {
          "url": "https://security.netapp.com/advisory/ntap-20210513-0002/"
        },
        {
          "url": "https://security.netapp.com/advisory/ntap-20210326-0006/"
        },
        {
          "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc"
        },
        {
          "url": "https://www.tenable.com/security/tns-2021-06"
        },
        {
          "url": "https://www.tenable.com/security/tns-2021-05"
        },
        {
          "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356"
        },
        {
          "url": "https://www.oracle.com//security-alerts/cpujul2021.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf"
        },
        {
          "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845"
        },
        {
          "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013"
        },
        {
          "name": "[debian-lts-announce] 20210831 [SECURITY] [DLA 2751-1] postgresql-9.6 security update",
          "tags": [
            "mailing-list"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html"
        },
        {
          "url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
        },
        {
          "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
        },
        {
          "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
        },
        {
          "url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
        }
      ],
      "title": "NULL pointer deref in signature_algorithms processing"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5",
    "assignerShortName": "openssl",
    "cveId": "CVE-2021-3449",
    "datePublished": "2021-03-25T14:25:13.659307Z",
    "dateReserved": "2021-03-17T00:00:00",
    "dateUpdated": "2024-09-17T03:43:55.497Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Vulnerability from fkie_nvd
Published
2021-03-25 15:15
Modified
2024-11-21 06:21
Summary
An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j).
References
openssl-security@openssl.orghttp://www.openwall.com/lists/oss-security/2021/03/27/1Mailing List, Third Party Advisory
openssl-security@openssl.orghttp://www.openwall.com/lists/oss-security/2021/03/27/2Mailing List, Third Party Advisory
openssl-security@openssl.orghttp://www.openwall.com/lists/oss-security/2021/03/28/3Mailing List, Third Party Advisory
openssl-security@openssl.orghttp://www.openwall.com/lists/oss-security/2021/03/28/4Mailing List, Third Party Advisory
openssl-security@openssl.orghttps://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdfThird Party Advisory
openssl-security@openssl.orghttps://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdfPatch, Third Party Advisory
openssl-security@openssl.orghttps://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148
openssl-security@openssl.orghttps://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845Third Party Advisory
openssl-security@openssl.orghttps://kc.mcafee.com/corporate/index?page=content&id=SB10356Third Party Advisory
openssl-security@openssl.orghttps://lists.debian.org/debian-lts-announce/2021/08/msg00029.htmlMailing List, Third Party Advisory
openssl-security@openssl.orghttps://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/
openssl-security@openssl.orghttps://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013Third Party Advisory
openssl-security@openssl.orghttps://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.ascThird Party Advisory
openssl-security@openssl.orghttps://security.gentoo.org/glsa/202103-03Third Party Advisory
openssl-security@openssl.orghttps://security.netapp.com/advisory/ntap-20210326-0006/Third Party Advisory
openssl-security@openssl.orghttps://security.netapp.com/advisory/ntap-20210513-0002/Third Party Advisory
openssl-security@openssl.orghttps://security.netapp.com/advisory/ntap-20240621-0006/
openssl-security@openssl.orghttps://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJdThird Party Advisory
openssl-security@openssl.orghttps://www.debian.org/security/2021/dsa-4875Third Party Advisory
openssl-security@openssl.orghttps://www.openssl.org/news/secadv/20210325.txtVendor Advisory
openssl-security@openssl.orghttps://www.oracle.com//security-alerts/cpujul2021.htmlPatch, Third Party Advisory
openssl-security@openssl.orghttps://www.oracle.com/security-alerts/cpuApr2021.htmlPatch, Third Party Advisory
openssl-security@openssl.orghttps://www.oracle.com/security-alerts/cpuapr2022.htmlPatch, Third Party Advisory
openssl-security@openssl.orghttps://www.oracle.com/security-alerts/cpujul2022.htmlThird Party Advisory
openssl-security@openssl.orghttps://www.oracle.com/security-alerts/cpuoct2021.htmlThird Party Advisory
openssl-security@openssl.orghttps://www.tenable.com/security/tns-2021-05Third Party Advisory
openssl-security@openssl.orghttps://www.tenable.com/security/tns-2021-06Third Party Advisory
openssl-security@openssl.orghttps://www.tenable.com/security/tns-2021-09Third Party Advisory
openssl-security@openssl.orghttps://www.tenable.com/security/tns-2021-10Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2021/03/27/1Mailing List, Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2021/03/27/2Mailing List, Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2021/03/28/3Mailing List, Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2021/03/28/4Mailing List, Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdfThird Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdfPatch, Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148
af854a3a-2127-422b-91ae-364da2661108https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://kc.mcafee.com/corporate/index?page=content&id=SB10356Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://lists.debian.org/debian-lts-announce/2021/08/msg00029.htmlMailing List, Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/
af854a3a-2127-422b-91ae-364da2661108https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.ascThird Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://security.gentoo.org/glsa/202103-03Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://security.netapp.com/advisory/ntap-20210326-0006/Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://security.netapp.com/advisory/ntap-20210513-0002/Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://security.netapp.com/advisory/ntap-20240621-0006/
af854a3a-2127-422b-91ae-364da2661108https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJdThird Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://www.debian.org/security/2021/dsa-4875Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://www.openssl.org/news/secadv/20210325.txtVendor Advisory
af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com//security-alerts/cpujul2021.htmlPatch, Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com/security-alerts/cpuApr2021.htmlPatch, Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com/security-alerts/cpuapr2022.htmlPatch, Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com/security-alerts/cpujul2022.htmlThird Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com/security-alerts/cpuoct2021.htmlThird Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://www.tenable.com/security/tns-2021-05Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://www.tenable.com/security/tns-2021-06Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://www.tenable.com/security/tns-2021-09Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://www.tenable.com/security/tns-2021-10Third Party Advisory
Impacted products
Vendor Product Version
openssl openssl *
debian debian_linux 9.0
debian debian_linux 10.0
freebsd freebsd 12.2
freebsd freebsd 12.2
freebsd freebsd 12.2
netapp active_iq_unified_manager -
netapp cloud_volumes_ontap_mediator -
netapp e-series_performance_analyzer -
netapp oncommand_insight -
netapp oncommand_workflow_automation -
netapp ontap_select_deploy_administration_utility -
netapp santricity_smi-s_provider -
netapp snapcenter -
netapp storagegrid -
tenable log_correlation_engine *
tenable nessus *
tenable nessus_network_monitor 5.11.0
tenable nessus_network_monitor 5.11.1
tenable nessus_network_monitor 5.12.0
tenable nessus_network_monitor 5.12.1
tenable nessus_network_monitor 5.13.0
tenable tenable.sc *
fedoraproject fedora 34
mcafee web_gateway 8.2.19
mcafee web_gateway 9.2.10
mcafee web_gateway 10.1.1
mcafee web_gateway_cloud_service 8.2.19
mcafee web_gateway_cloud_service 9.2.10
mcafee web_gateway_cloud_service 10.1.1
checkpoint quantum_security_management_firmware r80.40
checkpoint quantum_security_management_firmware r81
checkpoint quantum_security_management -
checkpoint multi-domain_management_firmware r80.40
checkpoint multi-domain_management_firmware r81
checkpoint multi-domain_management -
checkpoint quantum_security_gateway_firmware r80.40
checkpoint quantum_security_gateway_firmware r81
checkpoint quantum_security_gateway -
oracle communications_communications_policy_management 12.6.0.0.0
oracle enterprise_manager_for_storage_management 13.4.0.0
oracle essbase 21.2
oracle graalvm 19.3.5
oracle graalvm 20.3.1.2
oracle graalvm 21.0.0.2
oracle jd_edwards_enterpriseone_tools *
oracle jd_edwards_world_security a9.4
oracle mysql_connectors *
oracle mysql_server *
oracle mysql_server *
oracle mysql_workbench *
oracle peoplesoft_enterprise_peopletools 8.57
oracle peoplesoft_enterprise_peopletools 8.58
oracle peoplesoft_enterprise_peopletools 8.59
oracle primavera_unifier *
oracle primavera_unifier 19.12
oracle primavera_unifier 20.12
oracle primavera_unifier 21.12
oracle secure_backup *
oracle secure_global_desktop 5.6
oracle zfs_storage_appliance_kit 8.8
sonicwall sma100_firmware *
sonicwall sma100 -
sonicwall capture_client 3.5
sonicwall sonicos 7.0.1.0
siemens ruggedcom_rcm1224_firmware *
siemens ruggedcom_rcm1224 -
siemens scalance_lpe9403_firmware *
siemens scalance_lpe9403 -
siemens scalance_m-800_firmware *
siemens scalance_m-800 -
siemens scalance_s602_firmware *
siemens scalance_s602 -
siemens scalance_s612_firmware *
siemens scalance_s612 -
siemens scalance_s615_firmware *
siemens scalance_s615 -
siemens scalance_s623_firmware *
siemens scalance_s623 -
siemens scalance_s627-2m_firmware *
siemens scalance_s627-2m -
siemens scalance_sc-600_firmware *
siemens scalance_sc-600 -
siemens scalance_w700_firmware *
siemens scalance_w700 -
siemens scalance_w1700_firmware *
siemens scalance_w1700 -
siemens scalance_xb-200_firmware *
siemens scalance_xb-200 -
siemens scalance_xc-200_firmware *
siemens scalance_xc-200 -
siemens scalance_xf-200ba_firmware *
siemens scalance_xf-200ba -
siemens scalance_xm-400_firmware *
siemens scalance_xm-400 -
siemens scalance_xp-200_firmware *
siemens scalance_xp-200 -
siemens scalance_xr-300wg_firmware *
siemens scalance_xr-300wg -
siemens scalance_xr524-8c_firmware *
siemens scalance_xr524-8c -
siemens scalance_xr526-8c_firmware *
siemens scalance_xr526-8c -
siemens scalance_xr528-6m_firmware *
siemens scalance_xr528-6m -
siemens scalance_xr552-12_firmware *
siemens scalance_xr552-12 -
siemens simatic_cloud_connect_7_firmware *
siemens simatic_cloud_connect_7_firmware -
siemens simatic_cloud_connect_7 -
siemens simatic_cp_1242-7_gprs_v2_firmware *
siemens simatic_cp_1242-7_gprs_v2_firmware -
siemens simatic_cp_1242-7_gprs_v2 -
siemens simatic_hmi_basic_panels_2nd_generation_firmware *
siemens simatic_hmi_basic_panels_2nd_generation -
siemens simatic_hmi_comfort_outdoor_panels_firmware *
siemens simatic_hmi_comfort_outdoor_panels -
siemens simatic_hmi_ktp_mobile_panels_firmware *
siemens simatic_hmi_ktp_mobile_panels -
siemens simatic_mv500_firmware *
siemens simatic_mv500 -
siemens simatic_net_cp_1243-1_firmware *
siemens simatic_net_cp_1243-1 -
siemens simatic_net_cp1243-7_lte_eu_firmware *
siemens simatic_net_cp1243-7_lte_eu -
siemens simatic_net_cp1243-7_lte_us_firmware *
siemens simatic_net_cp1243-7_lte_us -
siemens simatic_net_cp_1243-8_irc_firmware *
siemens simatic_net_cp_1243-8_irc -
siemens simatic_net_cp_1542sp-1_irc_firmware *
siemens simatic_net_cp_1542sp-1_irc -
siemens simatic_net_cp_1543-1_firmware *
siemens simatic_net_cp_1543-1 -
siemens simatic_net_cp_1543sp-1_firmware *
siemens simatic_net_cp_1543sp-1 -
siemens simatic_net_cp_1545-1_firmware *
siemens simatic_net_cp_1545-1 -
siemens simatic_pcs_7_telecontrol_firmware *
siemens simatic_pcs_7_telecontrol -
siemens simatic_pcs_neo_firmware *
siemens simatic_pcs_neo -
siemens simatic_pdm_firmware *
siemens simatic_pdm -
siemens simatic_process_historian_opc_ua_server_firmware *
siemens simatic_process_historian_opc_ua_server -
siemens simatic_rf166c_firmware *
siemens simatic_rf166c -
siemens simatic_rf185c_firmware *
siemens simatic_rf185c -
siemens simatic_rf186c_firmware *
siemens simatic_rf186c -
siemens simatic_rf186ci_firmware *
siemens simatic_rf186ci -
siemens simatic_rf188c_firmware *
siemens simatic_rf188c -
siemens simatic_rf188ci_firmware *
siemens simatic_rf188ci -
siemens simatic_rf360r_firmware *
siemens simatic_rf360r -
siemens simatic_s7-1200_cpu_1211c_firmware *
siemens simatic_s7-1200_cpu_1211c -
siemens simatic_s7-1200_cpu_1212c_firmware *
siemens simatic_s7-1200_cpu_1212c -
siemens simatic_s7-1200_cpu_1212fc_firmware *
siemens simatic_s7-1200_cpu_1212fc -
siemens simatic_s7-1200_cpu_1214_fc_firmware *
siemens simatic_s7-1200_cpu_1214_fc -
siemens simatic_s7-1200_cpu_1214c_firmware *
siemens simatic_s7-1200_cpu_1214c -
siemens simatic_s7-1200_cpu_1214_fc_firmware *
siemens simatic_s7-1200_cpu_1214_fc -
siemens simatic_s7-1200_cpu_1215_fc_firmware *
siemens simatic_s7-1200_cpu_1215_fc -
siemens simatic_s7-1200_cpu_1215c_firmware *
siemens simatic_s7-1200_cpu_1215c -
siemens simatic_s7-1200_cpu_1217c_firmware *
siemens simatic_s7-1200_cpu_1217c -
siemens simatic_s7-1500_cpu_1518-4_pn\/dp_mfp_firmware *
siemens simatic_s7-1500_cpu_1518-4_pn\/dp_mfp -
siemens sinamics_connect_300_firmware *
siemens sinamics_connect_300 -
siemens tim_1531_irc_firmware *
siemens tim_1531_irc -
siemens simatic_logon *
siemens simatic_logon 1.5
siemens simatic_wincc_runtime_advanced *
siemens simatic_wincc_telecontrol -
siemens sinec_nms 1.0
siemens sinec_nms 1.0
siemens sinec_pni -
siemens sinema_server 14.0
siemens sinema_server 14.0
siemens sinema_server 14.0
siemens sinema_server 14.0
siemens sinema_server 14.0
siemens sinumerik_opc_ua_server *
siemens tia_administrator *
siemens sinec_infrastructure_network_services *
nodejs node.js *
nodejs node.js *
nodejs node.js *
nodejs node.js *
nodejs node.js *
nodejs node.js *
nodejs node.js *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:openssl:openssl:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B213E696-A6D9-45E7-B4E4-E4CFE54ECEB8",
              "versionEndExcluding": "1.1.1k",
              "versionStartIncluding": "1.1.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:debian:debian_linux:9.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "DEECE5FC-CACF-4496-A3E7-164736409252",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:debian:debian_linux:10.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "07B237A9-69A3-4A9C-9DA0-4E06BD37AE73",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:freebsd:freebsd:12.2:-:*:*:*:*:*:*",
              "matchCriteriaId": "73D9C08B-8F5B-40C4-A5BD-B00D2E4C012D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:freebsd:freebsd:12.2:p1:*:*:*:*:*:*",
              "matchCriteriaId": "62A178A3-6A52-4981-9A27-FB07AD8AF778",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:freebsd:freebsd:12.2:p2:*:*:*:*:*:*",
              "matchCriteriaId": "54A487B1-E5CE-4C76-87E8-518D24C5D86D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:netapp:active_iq_unified_manager:-:*:*:*:*:vmware_vsphere:*:*",
              "matchCriteriaId": "3A756737-1CC4-42C2-A4DF-E1C893B4E2D5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:netapp:cloud_volumes_ontap_mediator:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "280AA828-6FA9-4260-8EC1-019423B966E1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:netapp:e-series_performance_analyzer:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "24B8DB06-590A-4008-B0AB-FCD1401C77C6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:netapp:oncommand_insight:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F1BE6C1F-2565-4E97-92AA-16563E5660A5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:netapp:oncommand_workflow_automation:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5735E553-9731-4AAC-BCFF-989377F817B3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:netapp:ontap_select_deploy_administration_utility:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E7CF3019-975D-40BB-A8A4-894E62BD3797",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:netapp:santricity_smi-s_provider:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "361B791A-D336-4431-8F68-8135BEFFAEA2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:netapp:snapcenter:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BDFB1169-41A0-4A86-8E4F-FDA9730B1E94",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:netapp:storagegrid:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8ADFF451-740F-4DBA-BD23-3881945D3E40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:tenable:log_correlation_engine:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4ACF85D6-6B45-43DA-9C01-F0208186F014",
              "versionEndExcluding": "6.0.9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:tenable:nessus:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AC12300-9051-4C70-9941-9FE5E64B4B30",
              "versionEndIncluding": "8.13.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.11.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "657682A0-54D5-4DC6-A98E-8BAF685926C4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.11.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "8FC5C76C-3474-4B26-8CF0-2DFAFA3D5458",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.12.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "8661D361-71B5-4C41-A818-C89EC551D900",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.12.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "253603DC-2D92-442A-B3A8-A63E14D8A070",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.13.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "8E112CFF-31F9-4D87-9A1B-AE0FCF69615E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:tenable:tenable.sc:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AC1721B5-9FCD-47C3-8338-E02932CF2C05",
              "versionEndIncluding": "5.17.0",
              "versionStartIncluding": "5.13.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:fedoraproject:fedora:34:*:*:*:*:*:*:*",
              "matchCriteriaId": "A930E247-0B43-43CB-98FF-6CE7B8189835",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mcafee:web_gateway:8.2.19:*:*:*:*:*:*:*",
              "matchCriteriaId": "DEA7F1FD-9FAB-4654-98B0-4588EEC8B69A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mcafee:web_gateway:9.2.10:*:*:*:*:*:*:*",
              "matchCriteriaId": "868B2C4B-CE6B-41DA-A373-7D4FA51EFE9F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mcafee:web_gateway:10.1.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "550F47A2-3393-481E-BC40-CE606BFA8776",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mcafee:web_gateway_cloud_service:8.2.19:*:*:*:*:*:*:*",
              "matchCriteriaId": "43392D27-6C07-41C7-A17F-10C433338CE9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mcafee:web_gateway_cloud_service:9.2.10:*:*:*:*:*:*:*",
              "matchCriteriaId": "8FBF6C4C-195F-49A7-861D-52677D9BE58D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mcafee:web_gateway_cloud_service:10.1.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "90732D53-E802-4E1B-B6C8-B1FDCE7905A4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:checkpoint:quantum_security_management_firmware:r80.40:*:*:*:*:*:*:*",
              "matchCriteriaId": "A98B128A-C58E-48EC-B691-AF73126A0822",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:checkpoint:quantum_security_management_firmware:r81:*:*:*:*:*:*:*",
              "matchCriteriaId": "345B990F-C1C4-440B-804E-0A2882FE7C01",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:checkpoint:quantum_security_management:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "08601413-25E2-4977-B67A-C11A9D788EA8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:checkpoint:multi-domain_management_firmware:r80.40:*:*:*:*:*:*:*",
              "matchCriteriaId": "EFC067CC-EB90-43F5-9674-089D5C611573",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:checkpoint:multi-domain_management_firmware:r81:*:*:*:*:*:*:*",
              "matchCriteriaId": "80B223A7-1039-445D-ABE1-5E481004D956",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:checkpoint:multi-domain_management:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1584E1B4-412C-40E2-BF07-4E464692F2AE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:checkpoint:quantum_security_gateway_firmware:r80.40:*:*:*:*:*:*:*",
              "matchCriteriaId": "A0002A29-8B42-445D-9EC4-58BC93194241",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:checkpoint:quantum_security_gateway_firmware:r81:*:*:*:*:*:*:*",
              "matchCriteriaId": "3B0EDB21-9305-4601-AB96-A77BD00F311D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:checkpoint:quantum_security_gateway:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9016DDF6-285C-4E64-88D0-29ECCEF048F8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:oracle:communications_communications_policy_management:12.6.0.0.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "570DB369-A31B-4108-A7FD-09F674129603",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:enterprise_manager_for_storage_management:13.4.0.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "61516569-C48F-4362-B334-8CA10EDB0EC2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:essbase:21.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "394A16F2-CCD4-44E5-BF6B-E0C782A9FA38",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:graalvm:19.3.5:*:*:*:enterprise:*:*:*",
              "matchCriteriaId": "058C7C4B-D692-49DE-924A-C2725A8162D3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:graalvm:20.3.1.2:*:*:*:enterprise:*:*:*",
              "matchCriteriaId": "0F0434A5-F2A1-4973-917C-A95F2ABE97D1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:graalvm:21.0.0.2:*:*:*:enterprise:*:*:*",
              "matchCriteriaId": "96DD93E0-274E-4C36-99F3-EEF085E57655",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:jd_edwards_enterpriseone_tools:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "86305E47-33E9-411C-B932-08C395C09982",
              "versionEndExcluding": "9.2.6.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:jd_edwards_world_security:a9.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B1CAD50-749F-4ADB-A046-BF3585677A58",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:mysql_connectors:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A8782A14-89B0-45EE-A5CB-FF715F5BA379",
              "versionEndIncluding": "8.0.23",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:mysql_server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5C40ECC8-933B-47A4-8082-FCF0EF9C973E",
              "versionEndIncluding": "5.7.33",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:mysql_server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "32714AD7-BCD1-4624-9923-5E6D927CF3CB",
              "versionEndIncluding": "8.0.23",
              "versionStartIncluding": "8.0.15",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:mysql_workbench:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB1A94E1-A6C6-488D-A74C-6C0B24637272",
              "versionEndIncluding": "8.0.23",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:8.57:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E1E416B-920B-49A0-9523-382898C2979D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:8.58:*:*:*:*:*:*:*",
              "matchCriteriaId": "D9DB4A14-2EF5-4B54-95D2-75E6CF9AA0A9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:8.59:*:*:*:*:*:*:*",
              "matchCriteriaId": "C8AF00C6-B97F-414D-A8DF-057E6BFD8597",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:primavera_unifier:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "08FA59A8-6A62-4B33-8952-D6E658F8DAC9",
              "versionEndIncluding": "17.12",
              "versionStartIncluding": "17.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:primavera_unifier:19.12:*:*:*:*:*:*:*",
              "matchCriteriaId": "10864586-270E-4ACF-BDCC-ECFCD299305F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:primavera_unifier:20.12:*:*:*:*:*:*:*",
              "matchCriteriaId": "38340E3C-C452-4370-86D4-355B6B4E0A06",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:primavera_unifier:21.12:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9C55C69-E22E-4B80-9371-5CD821D79FE2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:secure_backup:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C01E8B82-71C7-4A4A-A70A-7B147524AB4A",
              "versionEndExcluding": "18.1.0.1.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:secure_global_desktop:5.6:*:*:*:*:*:*:*",
              "matchCriteriaId": "9DA11710-9EA8-49B4-8FD1-3AEE442F6ADC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:zfs_storage_appliance_kit:8.8:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3E503FB-6279-4D4A-91D8-E237ECF9D2B0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:sonicwall:sma100_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E8B6D50-D482-43E9-A20D-FA77FD59AE2D",
              "versionEndExcluding": "10.2.1.0-17sv",
              "versionStartIncluding": "10.2.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:sonicwall:sma100:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8E4A2B7B-40F5-4AE0-ACC7-E94B82435DBA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:sonicwall:capture_client:3.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "349EB4AE-65E3-42DC-8F9C-3A1A155324D7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:sonicwall:sonicos:7.0.1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "2BD8688A-2D55-4A7E-A143-1BD0FCF957B0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ruggedcom_rcm1224_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5081E52B-E7C0-46BD-B1D0-2C70ABCC8831",
              "versionStartIncluding": "6.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ruggedcom_rcm1224:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3747CDD7-E833-4B68-A362-77D6A2E9D888",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_lpe9403_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "058D21EA-E94C-4DDC-AD92-967DAC934457",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_lpe9403:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "52A77C9D-E59C-4397-B834-797D7B334A6B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "424CD8EA-D8CB-40C7-8E0F-AC4B05C59C99",
              "versionStartIncluding": "6.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFB9921A-5204-40A3-88AB-B7755F5C6875",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_s602_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "858B6A84-5D0E-4E23-AE32-A45B51BAC8CF",
              "versionStartIncluding": "4.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s602:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4D89D82-C2CE-44DC-A05B-B956F20BF4E3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_s612_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D173626B-9C50-489F-8BA4-1C45E5F96526",
              "versionStartIncluding": "4.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s612:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA7B48D2-0D17-420D-AAE1-35E5C0BE2924",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E967F5FC-6F3E-4982-8813-CA1DAF3BE165",
              "versionStartIncluding": "6.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E917CBBB-EF41-4113-B0CA-EB91889235E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_s623_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "81F315D8-0B26-4442-B330-85124017A482",
              "versionStartIncluding": "4.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s623:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F80D9A79-7984-462B-B4B9-6A4429422038",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_s627-2m_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F20F735-7A70-4A24-9621-786F99C8F87D",
              "versionStartIncluding": "4.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s627-2m:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B51B40F8-71D2-4D2D-8EC2-CE154A6D7533",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_sc-600_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "973B8030-B630-4D67-B897-25A359A96185",
              "versionStartIncluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_sc-600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "725C671B-D7A0-48CF-8A31-5F9C4173F1DD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w700_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "86EA8E3F-81BD-47BC-9834-A9B69CA7E70C",
              "versionStartIncluding": "6.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w700:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3033B1E-57A6-4AE3-A861-7047CF8EAD79",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w1700_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BE116AD9-B55F-41C8-8B55-329809DB63E1",
              "versionStartIncluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w1700:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D9A73DD-4A21-4096-B4B6-A0A825E71006",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "144CDF5E-7E07-428B-B4DF-C94992B3A44A",
              "versionEndExcluding": "4.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb-200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6CB3CC2D-CBF0-4F53-A412-01BBC39E34C2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "339FFBDF-6957-481F-84CE-878B5CAAD9C8",
              "versionEndExcluding": "4.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc-200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7719E194-EE3D-4CE8-8C85-CF0D82A553AA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xf-200ba_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FBB13D3-4E04-4D01-B880-C16C4FFA240B",
              "versionEndExcluding": "4.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xf-200ba:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58377C58-F660-4C17-A3CB-BFC2F28848CD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm-400_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E40058B3-3726-4F6A-AB41-7679487639F2",
              "versionEndExcluding": "6.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm-400:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "798E900F-5EF9-4B39-B8C2-79FAE659E7F5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E642D10-E701-44DF-863B-D0DAA5530F50",
              "versionEndExcluding": "4.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp-200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F962FC7-0616-467F-8CCA-ADEA224B5F7B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr-300wg_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A53C2B5-A3FD-44CC-A78B-D2124EF37DB4",
              "versionEndExcluding": "4.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr-300wg:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "434BC9BE-C5DB-4DAF-8E07-DFE4EEA0D7FE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr524-8c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "54FBE4D4-F31E-4B61-9216-44C8EC2988AB",
              "versionEndExcluding": "6.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr524-8c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0E6B7D8-3F9E-43D6-AEFE-DEE3993679C5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr526-8c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "20511D61-FC1D-453E-BDF6-D3FB9951192A",
              "versionEndExcluding": "6.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr526-8c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "67661569-6233-4C74-9C72-88BD14B257FE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr528-6m_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "640AC619-B516-46FC-821B-09C4542A3FD6",
              "versionEndExcluding": "6.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr528-6m:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3E048C4A-A414-4C87-A865-4D4218AE32EE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr552-12_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1FB979DB-731B-4693-A9F8-B11ED953717C",
              "versionEndExcluding": "6.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr552-12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "09743616-31C9-4E47-8A4A-B15D76204BE7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cloud_connect_7_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "886D2FE6-B054-4E3B-BACB-F08C0A119A80",
              "versionStartIncluding": "1.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cloud_connect_7_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3B185B70-CAC9-47AC-8639-7A4707C21540",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cloud_connect_7:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9FA78457-260C-467B-9785-04B3C8EDF3B3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1242-7_gprs_v2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "ABEA3BEE-E7AF-4C9A-ADE4-CE7FC1DB7639",
              "versionStartIncluding": "3.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1242-7_gprs_v2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "049460B8-6186-44F9-B41F-284A2EC0B3B4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1242-7_gprs_v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "205482DA-548C-4757-91F0-1599438873BD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_basic_panels_2nd_generation_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "45208694-635A-42AC-B668-8B67C60568B8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_basic_panels_2nd_generation:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7D8F8BCE-35CE-492A-8BFE-2C36EA51CE5C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B4C147D9-4649-4289-B18B-55BD6E33521A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4830E0D-0128-4E5B-AB81-2B238471AE4B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "54EFA8B5-8DA1-4547-9E15-BDC265C56006",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B1CEB200-E38F-4629-9279-5AF065396678",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_mv500_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DE4FA1E6-4C5A-4CDC-AD40-E384C0BCA90D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_mv500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "93A5B50E-0316-4189-8F41-54732CFCF63F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D254DA1D-C53E-426B-9C69-580CC47CF0AA",
              "versionStartIncluding": "3.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1243-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "65278BA0-3C81-4D81-9801-D7BE3A1D7680",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_net_cp1243-7_lte_eu_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C06A02ED-0BA3-4A2C-AF0C-689B8AEB34B8",
              "versionStartIncluding": "3.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_net_cp1243-7_lte_eu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "209C7B1E-10F6-4215-AF69-CC36192E0FCE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_net_cp1243-7_lte_us_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF8C00EE-1154-440C-A223-A2CE99CE3126",
              "versionStartIncluding": "3.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_net_cp1243-7_lte_us:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "171A9543-E677-422F-8AEA-1BC2D0E53593",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1243-8_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DB201DD3-8890-453E-A11E-1E13B3DAB3F9",
              "versionStartIncluding": "3.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1243-8_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "350FD323-C876-4C7A-A2E7-4B0660C87F6C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "61E498B1-87FF-454B-8DF0-61D0D3208491",
              "versionStartIncluding": "2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1542sp-1_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1EE2F10-A7A6-486F-AE5C-53AE25BAF200",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1543-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "90FB801F-11B5-438C-98A1-E928BFEA2ADB",
              "versionEndExcluding": "3.0",
              "versionStartIncluding": "2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1543-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F56C2BDC-928E-491A-8E7C-F976B3787C7A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8E4BA1E6-64F7-4B96-8302-134057DAB1BE",
              "versionStartIncluding": "2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1543sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "783B50B8-2FB7-4982-88AA-B4F2AD094796",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1545-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1DCA9544-DD17-4F56-B34C-91A3F37154AF",
              "versionStartIncluding": "1.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1545-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1256EB4B-DD8A-4F99-AE69-F74E8F789C63",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_pcs_7_telecontrol_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5C25165E-EDE9-42F1-A3B9-0E47630D49CC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_pcs_7_telecontrol:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5BF281FB-26E0-43E4-A2B6-4015661368AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_pcs_neo_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6EEACFC9-41B7-4EE0-9427-692363880326",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_pcs_neo:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EF3CA343-CA2A-4593-930C-158612CE7A55",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_pdm_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E9AE23E-7DAE-4191-BA4E-A7CD655C4BC8",
              "versionStartIncluding": "9.1.0.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_pdm:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E092B735-42D5-48D5-947B-288C0FA2E180",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_process_historian_opc_ua_server_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D874D636-392A-4750-B976-F411DBCEBA8D",
              "versionStartIncluding": "2019",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_process_historian_opc_ua_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "14EC9343-7778-40B0-A74D-5C156FF2A229",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf166c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "968FBB4E-5B0B-43D4-B3AD-418028093990",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf166c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "391AD485-A49D-43D0-AAE5-1F58B38D4E22",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf185c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5212F097-B65A-4D73-BB6F-49687F8AD980",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf185c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "82494B5E-80EE-47ED-B87E-CF8C8907B6FE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf186c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D806113B-57EB-4AA0-9D5E-12E30337A93B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf186c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B0933EB-82BE-42BB-978B-C9EC2FE1C795",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf186ci_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "53FA50A7-2DF6-454E-8A8E-838C392AB417",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf186ci:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1EAEB335-BD22-4CEF-A3EA-9D98A09FEBF0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf188c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F3D41E9-58B3-4251-8710-A8C4A24ABBD3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf188c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E21F9909-8D80-40BE-81E0-6ED7FE140A3A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf188ci_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FC628CB7-0816-4267-9C5D-954BD0233D2E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf188ci:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0927991-E820-4FC3-9EFE-96E4C9BFCCCD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf360r_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "88E64167-16AA-48D7-BCDC-B15D37FA666D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf360r:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "63F05227-208B-42C8-8D56-A5D106CAD32F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "47F1294A-1C26-4D43-9C53-D833F2510536",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4AF60081-D534-44F5-972F-23257F16F372",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AEF1726E-B56F-4D39-AFF4-E79A3CA00DE6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "68B3573B-A31E-4489-B2DD-B01B5C1D03CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214_fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9CC4A9F7-9858-4F95-8097-F8D09DA61314",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214_fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B640800C-9263-4BEA-9DA5-1323932540BD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4948734A-0AAD-4D28-B7FF-FFBBB9AA39C6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214_fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9CC4A9F7-9858-4F95-8097-F8D09DA61314",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214_fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B640800C-9263-4BEA-9DA5-1323932540BD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215_fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6EE37798-B068-40E5-BC03-1D8D303E5926",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215_fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "76C7D55C-8D99-4E2F-A254-1BDE2B12A203",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8E0C491C-5C4A-4F1C-ABD4-9502A54AAA78",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E7657063-1296-4734-B108-A2FF7A01B07F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_mfp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8C477CCD-06C7-4907-8B0C-4FCE7F6DADAD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_mfp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BC4FA01-8DDB-41E4-B759-7B504F78AEBC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_connect_300_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3360ACCE-E735-4E34-B278-0D4460E74CBF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_connect_300:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7B854F5B-78C7-41FE-9364-5E71B36342A3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:tim_1531_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D2B20D95-C4B3-4D13-A3D8-F22AC42DC059",
              "versionEndExcluding": "2.2",
              "versionStartIncluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1D94BEB-BBFB-4258-9835-87DBBB999239",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_logon:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D6F24E40-F3F0-48F3-B3DC-5F98B0564F7A",
              "versionStartIncluding": "1.6.0.2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_logon:1.5:sp3_update_1:*:*:*:*:*:*",
              "matchCriteriaId": "423359E5-9C36-4C6B-AB24-B030E6C61D53",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "79EE15DC-74D3-4551-AAD0-EA0CB600DA76",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_telecontrol:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F3169FD3-CBA2-417C-95EF-4F8AE9FAB5AD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinec_nms:1.0:-:*:*:*:*:*:*",
              "matchCriteriaId": "4ED13FC8-63C0-42C6-A51C-C480C45327C2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinec_nms:1.0:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "E68FE047-8F53-46B8-82D4-9342B1C8CA55",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinec_pni:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1353DC31-FB12-427A-B1B2-9164A4BEE14B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:-:*:*:*:*:*:*",
              "matchCriteriaId": "B0A5CC25-A323-4D49-8989-5A417D12D646",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "A690BCD3-6497-43F7-8A51-E033B9121DC8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:sp2:*:*:*:*:*:*",
              "matchCriteriaId": "AA375D44-ECC5-4BD3-A3D5-6D2AA68782D5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:sp2_update1:*:*:*:*:*:*",
              "matchCriteriaId": "6CD26C73-B61F-424B-91C2-352E2CAE6666",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:sp2_update2:*:*:*:*:*:*",
              "matchCriteriaId": "DB4EA15F-ECA4-477F-948F-490FC90BC66A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinumerik_opc_ua_server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "ABA14E65-214C-431D-A49A-D8FC142D4541",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:tia_administrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "915B09CB-CA0A-445B-89D3-16AE9B08858E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:sinec_infrastructure_network_services:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0F46497-4AB0-49A7-9453-CC26837BF253",
              "versionEndExcluding": "1.0.1.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
              "matchCriteriaId": "25A3180B-21AF-4010-9DAB-41ADFD2D8031",
              "versionEndIncluding": "10.12.0",
              "versionStartIncluding": "10.0.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*",
              "matchCriteriaId": "43B199B4-D89C-483D-ACAE-6CB2A59EE67C",
              "versionEndIncluding": "10.24.0",
              "versionStartIncluding": "10.13.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
              "matchCriteriaId": "564ED5C8-50D7-413A-B88E-E62B6C07336A",
              "versionEndIncluding": "12.12.0",
              "versionStartIncluding": "12.0.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*",
              "matchCriteriaId": "3DEBF7C8-B000-47B9-B597-DC440F2603B3",
              "versionEndExcluding": "12.22.1",
              "versionStartIncluding": "12.13.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
              "matchCriteriaId": "428DCD7B-6F66-4F18-B780-5BD80143D482",
              "versionEndIncluding": "14.14.0",
              "versionStartIncluding": "14.0.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*",
              "matchCriteriaId": "380D03F3-6A7E-43A2-B002-FB2521FD3C58",
              "versionEndExcluding": "14.16.1",
              "versionStartIncluding": "14.15.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
              "matchCriteriaId": "3ED4D313-F372-4CC1-BE11-6BBA2F0E90E3",
              "versionEndExcluding": "15.14.0",
              "versionStartIncluding": "15.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)."
    },
    {
      "lang": "es",
      "value": "Un servidor OpenSSL TLS puede cometer un fallo si un cliente env\u00eda un mensaje ClientHello de renegociaci\u00f3n dise\u00f1ado maliciosamente.\u0026#xa0;Si una renegociaci\u00f3n de TLSv1.2 ClientHello omite la extensi\u00f3n signature_algorithms (donde estaba presente en el ClientHello inicial), pero incluye una extensi\u00f3n signature_algorithms_cert, se producir\u00e1 una desreferencia del puntero NULL, lo que conllevar\u00e1 un bloqueo y un ataque de denegaci\u00f3n de servicio.\u0026#xa0;Un servidor solo es vulnerable si tiene TLSv1.2 y la renegociaci\u00f3n habilitada (que es la configuraci\u00f3n predeterminada).\u0026#xa0;Los clientes de OpenSSL TLS no est\u00e1n afectados por este problema.\u0026#xa0;Todas las versiones de OpenSSL versi\u00f3n 1.1.1 est\u00e1n afectadas por este problema.\u0026#xa0;Los usuarios de estas versiones deben actualizar a OpenSSL versi\u00f3n 1.1.1k.\u0026#xa0;OpenSSL versi\u00f3n 1.0.2 no est\u00e1 afectado por este problema.\u0026#xa0;Corregido en OpenSSL versi\u00f3n 1.1.1k (Afectadas versiones 1.1.1-1.1.1j)"
    }
  ],
  "id": "CVE-2021-3449",
  "lastModified": "2024-11-21T06:21:33.050",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 4.3,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 5.9,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.2,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-03-25T15:15:13.450",
  "references": [
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf"
    },
    {
      "source": "openssl-security@openssl.org",
      "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html"
    },
    {
      "source": "openssl-security@openssl.org",
      "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.gentoo.org/glsa/202103-03"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.netapp.com/advisory/ntap-20210326-0006/"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.netapp.com/advisory/ntap-20210513-0002/"
    },
    {
      "source": "openssl-security@openssl.org",
      "url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.debian.org/security/2021/dsa-4875"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.openssl.org/news/secadv/20210325.txt"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://www.oracle.com//security-alerts/cpujul2021.html"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.tenable.com/security/tns-2021-05"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.tenable.com/security/tns-2021-06"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.tenable.com/security/tns-2021-09"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.tenable.com/security/tns-2021-10"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.gentoo.org/glsa/202103-03"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.netapp.com/advisory/ntap-20210326-0006/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.netapp.com/advisory/ntap-20210513-0002/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.debian.org/security/2021/dsa-4875"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.openssl.org/news/secadv/20210325.txt"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://www.oracle.com//security-alerts/cpujul2021.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.tenable.com/security/tns-2021-05"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.tenable.com/security/tns-2021-06"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.tenable.com/security/tns-2021-09"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.tenable.com/security/tns-2021-10"
    }
  ],
  "sourceIdentifier": "openssl-security@openssl.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-476"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-07-13 11:15
Modified
2024-12-10 14:15
Summary
Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial of service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device.
Impacted products
Vendor Product Version
siemens dk_standard_ethernet_controller_evaluation_kit_firmware *
siemens dk_standard_ethernet_controller_evaluation_kit -
siemens ek-ertec_200_evaulation_kit_firmware *
siemens ek-ertec_200_evaulation_kit -
siemens ek-ertec_200p_evaluation_kit_firmware *
siemens ek-ertec_200p_evaluation_kit -
siemens ruggedcom_rm1224_firmware *
siemens ruggedcom_rm1224 -
siemens scalance_m-800_firmware *
siemens scalance_m-800 -
siemens scalance_s615_firmware *
siemens scalance_s615 -
siemens scalance_w700_firmware *
siemens scalance_w700 -
siemens scalance_w1700_firmware *
siemens scalance_w1700 -
siemens scalance_x200-4_p_irt_firmware *
siemens scalance_x200-4_p_irt -
siemens scalance_x201-3p_irt_firmware *
siemens scalance_x201-3p_irt -
siemens scalance_x201-3p_irt_pro_firmware *
siemens scalance_x201-3p_irt_pro -
siemens scalance_x202-2_irt_firmware *
siemens scalance_x202-2_irt -
siemens scalance_x202-2p_irt_pro_firmware *
siemens scalance_x202-2p_irt_pro -
siemens scalance_x204_irt_firmware *
siemens scalance_x204_irt -
siemens scalance_x204_irt_pro_firmware *
siemens scalance_x204_irt_pro -
siemens scalance_x204-2_firmware *
siemens scalance_x204-2_ -
siemens scalance_x204-2fm_firmware *
siemens scalance_x204-2fm -
siemens scalance_x204-2ld_firmware *
siemens scalance_x204-2ld -
siemens scalance_x204-2ld_ts_firmware *
siemens scalance_x204-2ld_ts -
siemens scalance_x204-2ts_firmware *
siemens scalance_x204-2ts -
siemens scalance_x206-1_firmware *
siemens scalance_x206-1 -
siemens scalance_x206-1ld_firmware *
siemens scalance_x206-1ld -
siemens scalance_x208_firmware *
siemens scalance_x208 -
siemens scalance_x208pro_firmware *
siemens scalance_x208pro -
siemens scalance_x212-2_firmware *
siemens scalance_x212-2 -
siemens scalance_x212-2ld_firmware *
siemens scalance_x212-2ld -
siemens scalance_x216_firmware *
siemens scalance_x216 -
siemens scalance_x224_firmware *
siemens scalance_x224 -
siemens scalance_x302-7eec_firmware *
siemens scalance_x302-7eec -
siemens scalance_x304-2fe_firmware *
siemens scalance_x304-2fe -
siemens scalance_x306-1ldfe_firmware *
siemens scalance_x306-1ldfe -
siemens scalance_x307-2eec_firmware *
siemens scalance_x307-2eec -
siemens scalance_x307-3_firmware *
siemens scalance_x307-3 -
siemens scalance_x307-3ld_firmware *
siemens scalance_x307-3ld -
siemens scalance_x308-2_firmware *
siemens scalance_x308-2 -
siemens scalance_x308-2ld_firmware *
siemens scalance_x308-2ld -
siemens scalance_x308-2lh_firmware *
siemens scalance_x308-2lh -
siemens scalance_x308-2lh\+_firmware *
siemens scalance_x308-2lh\+ -
siemens scalance_x308-2m_firmware *
siemens scalance_x308-2m -
siemens scalance_x308-2m_poe_firmware *
siemens scalance_x308-2m_poe -
siemens scalance_x308-2m_ts_firmware *
siemens scalance_x308-2m_ts -
siemens scalance_x310_firmware *
siemens scalance_x310 -
siemens scalance_x310fe_firmware *
siemens scalance_x310fe -
siemens scalance_x320-1fe_firmware *
siemens scalance_x320-1fe -
siemens scalance_x320-3ldfe_firmware *
siemens scalance_x320-3ldfe -
siemens scalance_xb-200_firmware *
siemens scalance_xb-200 -
siemens scalance_xc-200_firmware *
siemens scalance_xc-200 -
siemens scalance_xf201-3p_irt_firmware *
siemens scalance_xf201-3p_irt -
siemens scalance_xf202-2p_irt_firmware *
siemens scalance_xf202-2p_irt -
siemens scalance_xf204_firmware *
siemens scalance_xf204 -
siemens scalance_xf204_irt_firmware *
siemens scalance_xf204_irt -
siemens scalance_xf204-2_firmware *
siemens scalance_xf204-2_ -
siemens scalance_xf204-2ba_irt_firmware *
siemens scalance_xf204-2ba_irt -
siemens scalance_xf206-1_firmware *
siemens scalance_xf206-1 -
siemens scalance_xf208_firmware *
siemens scalance_xf208 -
siemens scalance_xf-200ba_firmware *
siemens scalance_xf-200ba -
siemens scalance_xm400_firmware *
siemens scalance_xm400 -
siemens scalance_xp-200_firmware *
siemens scalance_xp-200 -
siemens scalance_xr324-4m_eec_firmware *
siemens scalance_xr324-4m_eec -
siemens scalance_xr324-4m_poe_firmware *
siemens scalance_xr324-4m_poe -
siemens scalance_xr324-4m_poe_ts_firmware *
siemens scalance_xr324-4m_poe_ts -
siemens scalance_xr324-12m_firmware *
siemens scalance_xr324-12m -
siemens scalance_xr324-12m_ts_firmware *
siemens scalance_xr324-12m_ts -
siemens scalance_xr500_firmware *
siemens scalance_xr500 -
siemens scalance_xr-300wg_firmware *
siemens scalance_xr-300wg -
siemens simatic_cfu_pa_firmware *
siemens simatic_cfu_pa -
siemens simatic_ie\/pb-link_v3_firmware *
siemens simatic_ie\/pb-link_v3 -
siemens simatic_mv500_firmware *
siemens simatic_mv500 -
siemens simatic_net_cm_1542-1_firmware *
siemens simatic_net_cm_1542-1 -
siemens simatic_net_cp1616_firmware *
siemens simatic_net_cp1616 -
siemens simatic_net_cp1604_firmware *
siemens simatic_net_cp1604 -
siemens simatic_net_cp1626_firmware *
siemens simatic_net_cp1626 -
siemens simatic_net_dk-16xx_pn_io *
siemens simatic_power_line_booster_plb_firmware *
siemens simatic_power_line_booster_plb -
siemens simatic_profinet_driver_firmware *
siemens simatic_profinet_driver -
siemens simatic_s7-1200_firmware *
siemens simatic_s7-1200 -
siemens simocode_prov_ethernet\/ip_firmware *
siemens simocode_prov_ethernet\/ip -
siemens simocode_prov_profinet_firmware *
siemens simocode_prov_profinet -
siemens softnet-ie_pnio_firmware *
siemens softnet-ie_pnio -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_evaluation_kit_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1BA1C1FD-EF49-488E-AB49-6F571D9E21B0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:dk_standard_ethernet_controller_evaluation_kit:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "83110E06-CDB2-49AE-B1E6-6785E0801A53",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ek-ertec_200_evaulation_kit_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "978998A4-C7B5-4D6D-9FAD-3C6F975C8881",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ek-ertec_200_evaulation_kit:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "12C60870-6B8C-4E91-B156-60D87B85543F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ek-ertec_200p_evaluation_kit_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "249935E8-C45B-4586-B6BA-664AF23C7468",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ek-ertec_200p_evaluation_kit:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "37176F8D-F1CB-4792-86FF-DA0FF674E0B8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ruggedcom_rm1224_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "758CC5D1-F26C-4093-BE09-0583F4CDBBDB",
              "versionEndExcluding": "6.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ruggedcom_rm1224:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "284DF779-D900-48B4-A177-7281CD445AB5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "02BC878B-BF73-4A2C-A9D5-F9FF0F3D418B",
              "versionEndExcluding": "6.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFB9921A-5204-40A3-88AB-B7755F5C6875",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4F5AD34D-61AA-47B0-993A-4834984893EA",
              "versionEndExcluding": "6.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E917CBBB-EF41-4113-B0CA-EB91889235E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w700_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F60CB864-640E-4BC2-B378-5AF3DCA292D4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w700:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3033B1E-57A6-4AE3-A861-7047CF8EAD79",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w1700_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "44B0E5EA-4924-4865-AE6F-2F7BFCE5513B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w1700:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D9A73DD-4A21-4096-B4B6-A0A825E71006",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x200-4_p_irt_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8FCE9120-8091-41EC-A75E-01ED4AF64E28",
              "versionEndExcluding": "5.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x200-4_p_irt:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "73E42E20-18CB-40A7-B6D5-751F26303995",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x201-3p_irt_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA86FF0D-7B16-4991-B4A5-AF33BF40693A",
              "versionEndExcluding": "5.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x201-3p_irt:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3268CF75-6DAB-416A-B19B-2A8F95C268CF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x201-3p_irt_pro_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA2326FF-5125-44F5-871C-2DC505E2B299",
              "versionEndExcluding": "5.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x201-3p_irt_pro:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "492E8AC1-338B-4AC3-90C7-1FADCD4528C4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x202-2_irt_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3A12E0F8-A7BB-48E9-98E5-7DA4962FA8AE",
              "versionEndExcluding": "5.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x202-2_irt:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "577D1E21-717C-4508-AE91-0BC490C89F85",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x202-2p_irt_pro_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "29C03AD0-7A60-4BFB-A0D3-BABB9717F1A1",
              "versionEndExcluding": "5.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x202-2p_irt_pro:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4726901-34BF-4F70-80A6-71648A4A29FB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x204_irt_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "576A1BD5-84DE-4FFC-926D-6C40E5176660",
              "versionEndExcluding": "5.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x204_irt:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0BC31F0E-389B-4925-88DE-726F2F0D2A23",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x204_irt_pro_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AFE2ABF4-2996-4671-A5AF-4424FB2537C1",
              "versionEndExcluding": "5.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x204_irt_pro:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8FF096BA-A6F4-46B3-9B9B-7FCEE7E6A6C3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x204-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "ACE1A821-8F0A-4B96-AC8A-B219215014B1",
              "versionEndExcluding": "5.2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x204-2_:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1AA16CFF-C01A-4AC0-A20E-50CBD3AA1C3E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x204-2fm_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "54201E08-15E3-4C93-9A0D-DC376B7C8D88",
              "versionEndExcluding": "5.2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x204-2fm:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1FCBC784-8EA0-4C6C-B504-DFC164028E4B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x204-2ld_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "75220631-DD7D-4E86-8405-F98340FFE27C",
              "versionEndExcluding": "5.2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x204-2ld:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2BE27611-53E7-4162-8630-5BC334B02E37",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x204-2ld_ts_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3032A499-DFD5-4FEA-8AC6-E661781387AB",
              "versionEndExcluding": "5.2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x204-2ld_ts:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1FDEBD6B-6BE4-4FAD-A4E6-BE762595434D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x204-2ts_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A493C49A-8BF9-43E5-98D5-55E5390A36A5",
              "versionEndExcluding": "5.2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x204-2ts:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5FFC1E9-4326-4F41-A86A-C52AB6A9A674",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x206-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E2C9747F-BEC3-486E-B553-3339F8B54C3A",
              "versionEndExcluding": "5.2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x206-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0A5BB0F2-DD4C-4AB4-9B8F-B2501B239080",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x206-1ld_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C8D68AC-8F30-4919-ADB3-A6018458602B",
              "versionEndExcluding": "5.2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x206-1ld:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6DFF7FB7-774B-45ED-8400-951230DF0511",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x208_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2BC1450A-92ED-451F-9890-4E18CA974485",
              "versionEndExcluding": "5.2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x208:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B3B574E2-F7BA-496B-887C-D25F386AA5E1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x208pro_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "768320F0-10F5-4B36-AEB6-9DEEA43A30E8",
              "versionEndExcluding": "5.2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x208pro:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DF2C60CF-4089-4993-A2CB-B7FBDAF81D62",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x212-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "31B8367C-5EAC-49F4-83B8-C7E3BD373092",
              "versionEndExcluding": "5.2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x212-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E716A4E-50A9-4C52-8DA9-098F7506F4B5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x212-2ld_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "55F50ABF-3E9A-4435-BAA4-7D11A2047D46",
              "versionEndExcluding": "5.2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x212-2ld:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C08CDEE3-43EB-475E-8571-6E12824714FD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x216_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BC643617-D0B7-4379-8ADB-2C2BACA4B165",
              "versionEndExcluding": "5.2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x216:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F0C4BAB5-E161-4B59-8A8C-369C7852A66E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x224_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F0189DF6-DA80-49FE-B09F-0C07D892518E",
              "versionEndExcluding": "5.2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x224:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D2203895-BC4E-4B2F-9110-C2CD88A121F2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x302-7eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EF92A1A7-ADFB-49E1-AC54-03E32ECB73CE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x302-7eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C8E97B3B-1808-45D2-97B7-CF31CA6E7A60",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x304-2fe_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "392D0623-343D-4BF1-BE0B-F2B347A24B62",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x304-2fe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0087A1C6-AA76-4FD6-BAA1-D3190D2A0116",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x306-1ldfe_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "663897D9-82F5-436D-A0CF-BBB9338BF363",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x306-1ldfe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "880CF41B-B25D-4744-8E8B-C4B131932B1B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x307-2eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9666E7EA-A298-4972-80F8-765B0F99EB25",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x307-2eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "804EE08B-75A1-4CF6-9C30-8CF0CDC39658",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x307-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9676DB10-982D-445F-9779-B39AE720AF2F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x307-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "55EF0738-C9EF-4E4B-A7E7-ECC1B5F0678A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x307-3ld_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "48D3EB09-6069-4289-A61E-C15B044EA2E2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x307-3ld:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7737F0C2-43FC-4330-88F2-9B08BA5B35D7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x308-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F045D6B1-459B-46F0-86DF-F9AA3CCEA9BD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x308-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6CCED3E4-38EF-4645-B25C-4F2C3D4E091C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x308-2ld_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "40A1A5F9-4971-4E9D-BBE7-5A0357C56213",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x308-2ld:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE1909FA-C8C6-46BE-83C6-2635D36FE69B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x308-2lh_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F53C74B-2154-417E-ACFE-01F0BACD3F15",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x308-2lh:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6DDBD94D-5312-4A54-AF76-D9DF791C0292",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x308-2lh\\+_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D76A2268-5397-466C-98B5-01B46B4840A1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x308-2lh\\+:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "85153EED-C677-495D-A6BB-72365DE1ED3F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2F8888A7-3285-4ACA-A5AD-2B0578050C4C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AC54911E-C432-48FA-9551-9644422FFE14",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x308-2m_poe_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C08597D-6190-4C73-9ECF-2535553DECAA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x308-2m_poe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3E22C57C-2BD6-4C39-93D2-5D81A58EA6F0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x308-2m_ts_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A2C12934-E79C-41A4-B023-BADD7D68CB55",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x308-2m_ts:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFCCB68C-A58D-4543-A11F-721B01FFBBA4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x310_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D288227C-69C1-4248-AB4A-51F44A41FDEA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x310:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7FE3716E-1C0A-4B72-809A-8318E5853FB1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x310fe_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "27F765CD-B8A9-45B6-BA3C-C569FF0F8FF0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x310fe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8FB34E83-83A3-45C3-B040-D8910971D439",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x320-1fe_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "91EDD23A-1DBD-4117-9396-89ADBC705B3A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x320-1fe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC54880F-CBF4-4772-A4FB-B07D97287D44",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x320-3ldfe_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AF07B014-1BA3-477E-A405-5DB35F68126A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x320-3ldfe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "80502856-7617-4ED9-A103-681021131EE0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "144CDF5E-7E07-428B-B4DF-C94992B3A44A",
              "versionEndExcluding": "4.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb-200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6CB3CC2D-CBF0-4F53-A412-01BBC39E34C2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "339FFBDF-6957-481F-84CE-878B5CAAD9C8",
              "versionEndExcluding": "4.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc-200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7719E194-EE3D-4CE8-8C85-CF0D82A553AA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xf201-3p_irt_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B5557DB0-D3D8-4E53-BBA8-700B2BC336C0",
              "versionEndExcluding": "5.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xf201-3p_irt:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "41614C70-97B4-44C8-A441-530A413A26F9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xf202-2p_irt_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1A7EDE9-B5F9-4471-8C5D-B1D590CB85FB",
              "versionEndExcluding": "5.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xf202-2p_irt:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6751FB7D-C72C-4321-B535-5880FE696FC3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xf204_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8CD13707-1164-415E-9083-7946D151F1FC",
              "versionEndExcluding": "5.2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xf204:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0F1AE867-67B4-4871-BF56-88017533A737",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xf204_irt_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "86FBD0DA-ADA4-4F06-A2D6-11D7312257A2",
              "versionEndExcluding": "5.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xf204_irt:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "25DDF1EB-80E7-491F-A197-1B220E35CDF1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xf204-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3A09FF2D-F369-47B5-AEE4-A862BEDD9851",
              "versionEndExcluding": "5.2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xf204-2_:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C4207E0-7678-4E35-A79E-A6066D1E8BB5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xf204-2ba_irt_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "786738CF-CA6C-4812-BD4D-595E249BFA76",
              "versionEndExcluding": "5.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xf204-2ba_irt:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "99E6AFAA-B903-47BB-B0F3-7650B039C0FB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xf206-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CFCDC84E-0695-409A-844B-D24024CC33F2",
              "versionEndExcluding": "5.2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xf206-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2B40D2EB-5C69-47FA-801B-DC48407D418C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xf208_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1DB6C03-71BF-4359-834B-384E78910E64",
              "versionEndExcluding": "5.2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xf208:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "898613B2-4A9D-44B9-A3FC-4347A2AD7CAB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xf-200ba_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FBB13D3-4E04-4D01-B880-C16C4FFA240B",
              "versionEndExcluding": "4.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xf-200ba:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58377C58-F660-4C17-A3CB-BFC2F28848CD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D589735-017F-4675-8056-CA4FE57360E8",
              "versionEndExcluding": "6.3.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm400:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9FC408A8-903F-43A2-9D05-65AD4482FDBB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E642D10-E701-44DF-863B-D0DAA5530F50",
              "versionEndExcluding": "4.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp-200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F962FC7-0616-467F-8CCA-ADEA224B5F7B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E6AB4BE-D669-4A95-8F8A-F2DA146D5FB1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr324-4m_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F952542-6B79-4681-A236-15C188AAEB1E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F4B8E2B-DEFF-4F1C-B5A4-0C4671C605C1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr324-4m_poe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "664D9C76-BC13-4874-939C-A8211DA33903",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9F4DE2B7-1AB3-4BA5-B261-926B774B01DD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr324-4m_poe_ts:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4834A67B-7B0B-4F88-BBFB-25667FD68EC5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr324-12m_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AC751E0-FC87-4DEB-85E8-C3E028B76482",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr324-12m:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "36C9AE74-4683-4ED0-A605-3A6B065C230E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB09860F-9DC8-476B-9AF7-6FFE57101D6C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr324-12m_ts:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4356417E-B4CB-45B0-B395-CE9D423FAB44",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "32E2B545-326C-4724-90BC-147B57A37F20",
              "versionEndExcluding": "6.3.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "080E722F-FCD4-4967-86EE-151ADC5702E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr-300wg_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A53C2B5-A3FD-44CC-A78B-D2124EF37DB4",
              "versionEndExcluding": "4.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr-300wg:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "434BC9BE-C5DB-4DAF-8E07-DFE4EEA0D7FE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cfu_pa_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A5119182-CB31-466A-AB0F-7956C8B45AE0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cfu_pa:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6C1E4CC-2657-4383-83D8-5C8F88B12755",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ie\\/pb-link_v3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9A8C0F9C-AF27-424C-83F0-326EC10C40BE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ie\\/pb-link_v3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "939D9324-2A7F-4DBF-8F9F-DB8A379C977A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_mv500_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CDEAC63C-E402-4698-B4A8-E9B53D5540DA",
              "versionEndExcluding": "3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_mv500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "93A5B50E-0316-4189-8F41-54732CFCF63F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_net_cm_1542-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "761C2EC9-51B9-482B-8798-7982D265933D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_net_cm_1542-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "40757A32-7347-4975-BC01-A1B28760D2C3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_net_cp1616_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4575EFA7-C453-466D-9C37-38FEE0B78053",
              "versionEndIncluding": "2.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_net_cp1616:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B971242-13BA-4217-8FB0-92ACDCE463CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_net_cp1604_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9F73267-3A7A-4A38-B999-9877B173B518",
              "versionEndIncluding": "2.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_net_cp1604:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A0DB421E-A774-451F-85AB-E66A4FAA33A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_net_cp1626_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "18143A38-84B8-479E-99FB-93FCA8CB058D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_net_cp1626:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5B0286CB-0566-4306-B069-789E5A4F168F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_net_dk-16xx_pn_io:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "78430123-6230-4B76-B163-CDA3FA77413C",
              "versionEndIncluding": "2.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_power_line_booster_plb_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2AAAECA7-6936-48AD-B617-79F4C708E47F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_power_line_booster_plb:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B7B52AEC-7A90-49F2-8006-FC146405C3E0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_profinet_driver_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CE64639F-FC6D-43F6-A300-9B5A62495B27",
              "versionEndExcluding": "2.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_profinet_driver:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "526493E9-EF74-4836-9A8F-134B625035AA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6870C5CC-B7E0-45C3-9D98-F90765EE153F",
              "versionEndExcluding": "4.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EC545350-FD53-4B2E-886F-E20F12260C9B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simocode_prov_ethernet\\/ip_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FBDC4FD6-06A6-4728-B8A0-D896CD89FD3E",
              "versionEndExcluding": "1.1.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simocode_prov_ethernet\\/ip:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6CBAF8CF-6159-46D2-AB92-7CB5BFA7467B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simocode_prov_profinet_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "27AC468E-63F9-443B-906C-D1794B846744",
              "versionEndExcluding": "2.1.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simocode_prov_profinet:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E595680D-555C-4A8E-A409-88CBCE6681E6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:softnet-ie_pnio_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "45650D6F-1F5F-4DC8-BF5C-C4FBE3D3E39D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:softnet-ie_pnio:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B8673C81-91F5-4E74-8C5F-829040F39E0C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial of service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device."
    },
    {
      "lang": "es",
      "value": "Los dispositivos afectados contienen una vulnerabilidad que permite a un atacante no autentificado desencadenar una condici\u00f3n de denegaci\u00f3n de servicio. La vulnerabilidad puede activarse si se env\u00eda una gran cantidad de paquetes de restablecimiento de DCP al dispositivo"
    }
  ],
  "id": "CVE-2020-28400",
  "lastModified": "2024-12-10T14:15:19.373",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.0,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "automatable": "NOT_DEFINED",
          "availabilityRequirements": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirements": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirements": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubsequentSystemAvailability": "NOT_DEFINED",
          "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED",
          "modifiedSubsequentSystemIntegrity": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnerableSystemAvailability": "NOT_DEFINED",
          "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED",
          "modifiedVulnerableSystemIntegrity": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "recovery": "NOT_DEFINED",
          "safety": "NOT_DEFINED",
          "subsequentSystemAvailability": "NONE",
          "subsequentSystemConfidentiality": "NONE",
          "subsequentSystemIntegrity": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "vulnerableSystemAvailability": "HIGH",
          "vulnerableSystemConfidentiality": "NONE",
          "vulnerableSystemIntegrity": "NONE"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2021-07-13T11:15:08.960",
  "references": [
    {
      "source": "productcert@siemens.com",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-599968.html"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-599968.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",