Vulnerabilites related to schneider-electric - scadapack_474
cve-2022-26507
Vulnerability from cvelistv5
Published
2022-04-14 12:04
Modified
2024-08-03 05:03
Severity ?
EPSS score ?
Summary
A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer
References
▼ | URL | Tags |
---|---|---|
https://Claroty.com | x_refsource_MISC | |
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02 | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T05:03:32.896Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://Claroty.com" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT\u0026T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer" } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-04-14T12:04:26", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://Claroty.com" }, { "tags": [ "x_refsource_MISC" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02" } ], "tags": [ "unsupported-when-assigned" ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2022-26507", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "** UNSUPPORTED WHEN ASSIGNED ** A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT\u0026T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://Claroty.com", "refsource": "MISC", "url": "https://Claroty.com" }, { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-26507", "datePublished": "2022-04-14T12:04:26", "dateReserved": "2022-03-06T00:00:00", "dateUpdated": "2024-08-03T05:03:32.896Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-22797
Vulnerability from cvelistv5
Published
2022-03-28 16:25
Modified
2024-08-03 18:51
Severity ?
EPSS score ?
Summary
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior, including former Unity Pro), EcoStruxure Process Expert (2020 and prior, including former HDCS), SCADAPack RemoteConnect for x70 (All versions)
References
▼ | URL | Tags |
---|---|---|
https://www.se.com/ww/en/download/document/SEVD-2021-257-01/ | x_refsource_MISC |
Impacted products
Vendor | Product | Version | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Schneider Electric | EcoStruxure Control Expert |
Version: unspecified < V15.0 SP1 |
|||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.527Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2021-257-01/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "EcoStruxure Control Expert", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V15.0 SP1", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "EcoStruxure Process Expert", "vendor": "Schneider Electric", "versions": [ { "lessThan": "2020", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "SCADAPack RemoteConnect for x70", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior, including former Unity Pro), EcoStruxure Process Expert (2020 and prior, including former HDCS), SCADAPack RemoteConnect for x70 (All versions)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-22", "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-04-13T15:45:24", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2021-257-01/" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22797", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "EcoStruxure Control Expert", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "V15.0 SP1" } ] } }, { "product_name": "EcoStruxure Process Expert", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "2020" } ] } }, { "product_name": "SCADAPack RemoteConnect for x70", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Schneider Electric" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior, including former Unity Pro), EcoStruxure Process Expert (2020 and prior, including former HDCS), SCADAPack RemoteConnect for x70 (All versions)" } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.se.com/ww/en/download/document/SEVD-2021-257-01/", "refsource": "MISC", "url": "https://www.se.com/ww/en/download/document/SEVD-2021-257-01/" } ] }, "source": { "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22797", "datePublished": "2022-03-28T16:25:24", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.527Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2022-04-13 16:15
Modified
2024-11-21 05:50
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior, including former Unity Pro), EcoStruxure Process Expert (2020 and prior, including former HDCS), SCADAPack RemoteConnect for x70 (All versions)
References
▼ | URL | Tags | |
---|---|---|---|
cybersecurity@se.com | https://www.se.com/ww/en/download/document/SEVD-2021-257-01/ | Mitigation, Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.se.com/ww/en/download/document/SEVD-2021-257-01/ | Mitigation, Patch, Vendor Advisory |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*", "matchCriteriaId": "8DCC0C29-32C2-4463-B98F-AB4B56FF5314", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_process_expert:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAB4A9EC-96A2-424D-A858-162E662EBEFB", "versionEndExcluding": "2021", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:remoteconnect:-:*:*:*:*:*:*:*", "matchCriteriaId": "3FFDF36B-30A5-4B35-956C-60DC15CE7EE4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:scadapack_470:-:*:*:*:*:*:*:*", "matchCriteriaId": "F51A7887-4F1A-428C-9E68-260E7262A678", "vulnerable": false }, { "criteria": "cpe:2.3:h:schneider-electric:scadapack_474:-:*:*:*:*:*:*:*", "matchCriteriaId": "58BACC54-6609-4DCE-AEEC-A9C2396635A0", "vulnerable": false }, { "criteria": "cpe:2.3:h:schneider-electric:scadapack_570:-:*:*:*:*:*:*:*", "matchCriteriaId": "FFDF44F3-2514-4CB0-A1A4-87123225B0F1", "vulnerable": false }, { "criteria": "cpe:2.3:h:schneider-electric:scadapack_574:-:*:*:*:*:*:*:*", "matchCriteriaId": "4F5CDC99-C4C8-43FE-8EA7-65C7EDFD9BA3", "vulnerable": false }, { "criteria": "cpe:2.3:h:schneider-electric:scadapack_575:-:*:*:*:*:*:*:*", "matchCriteriaId": "DE4172DF-94E3-4AEE-8D6B-9F48DC453B9E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior, including former Unity Pro), EcoStruxure Process Expert (2020 and prior, including former HDCS), SCADAPack RemoteConnect for x70 (All versions)" }, { "lang": "es", "value": "Una CWE-22: Se presenta una vulnerabilidad de Limitaci\u00f3n inadecuada de un nombre de ruta a un directorio restringido (\" Salto de Ruta\") que podr\u00eda causar la implementaci\u00f3n de scripts maliciosos en una ubicaci\u00f3n no autorizada y puede resultar en una ejecuci\u00f3n de c\u00f3digo en la estaci\u00f3n de trabajo de ingenier\u00eda cuando es cargado un archivo de proyecto malicioso en el software de ingenier\u00eda. Producto afectado: EcoStruxure Control Expert (versiones V15.0 SP1 y anteriores, incluido el antiguo Unity Pro), EcoStruxure Process Expert (versiones 2020 y anteriores, incluido el antiguo HDCS), SCADAPack RemoteConnect para x70 (Todas las versiones)" } ], "id": "CVE-2021-22797", "lastModified": "2024-11-21T05:50:41.417", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "cybersecurity@se.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-04-13T16:15:09.370", "references": [ { "source": "cybersecurity@se.com", "tags": [ "Mitigation", "Patch", "Vendor Advisory" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2021-257-01/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mitigation", "Patch", "Vendor Advisory" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2021-257-01/" } ], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-22" } ], "source": "cybersecurity@se.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2022-04-14 13:15
Modified
2024-11-21 06:54
Severity ?
Summary
A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://Claroty.com | Not Applicable, Third Party Advisory | |
cve@mitre.org | https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02 | Mitigation, Release Notes, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://Claroty.com | Not Applicable, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02 | Mitigation, Release Notes, Third Party Advisory |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:att:xmill:0.7:*:*:*:*:*:*:*", "matchCriteriaId": "4CC987F6-AAFA-4CDE-842D-EA7858A3E7F4", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*", "matchCriteriaId": "8DCC0C29-32C2-4463-B98F-AB4B56FF5314", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "78F6B1CC-488B-48E8-B96B-77A1894E9E92", "vulnerable": true }, { "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_process_expert:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAB4A9EC-96A2-424D-A858-162E662EBEFB", "versionEndExcluding": "2021", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:remoteconnect:-:*:*:*:*:*:*:*", "matchCriteriaId": "3FFDF36B-30A5-4B35-956C-60DC15CE7EE4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:scadapack_470:-:*:*:*:*:*:*:*", "matchCriteriaId": "F51A7887-4F1A-428C-9E68-260E7262A678", "vulnerable": false }, { "criteria": "cpe:2.3:h:schneider-electric:scadapack_474:-:*:*:*:*:*:*:*", "matchCriteriaId": "58BACC54-6609-4DCE-AEEC-A9C2396635A0", "vulnerable": false }, { "criteria": "cpe:2.3:h:schneider-electric:scadapack_570:-:*:*:*:*:*:*:*", "matchCriteriaId": "FFDF44F3-2514-4CB0-A1A4-87123225B0F1", "vulnerable": false }, { "criteria": "cpe:2.3:h:schneider-electric:scadapack_574:-:*:*:*:*:*:*:*", "matchCriteriaId": "4F5CDC99-C4C8-43FE-8EA7-65C7EDFD9BA3", "vulnerable": false }, { "criteria": "cpe:2.3:h:schneider-electric:scadapack_575:-:*:*:*:*:*:*:*", "matchCriteriaId": "DE4172DF-94E3-4AEE-8D6B-9F48DC453B9E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [ { "sourceIdentifier": "cve@mitre.org", "tags": [ "unsupported-when-assigned" ] } ], "descriptions": [ { "lang": "en", "value": "A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT\u0026T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer" }, { "lang": "es", "value": "** NO SOPORTADO CUANDO SE ASIGN\u00d3 ** Se presenta un desbordamiento de b\u00fafer en la regi\u00f3n heap de la memoria en XML Decompression DecodeTreeBlock en AT\u0026amp;T Labs Xmill versi\u00f3n 0.7. Un archivo de entrada dise\u00f1ado puede conllevar a una ejecuci\u00f3n de c\u00f3digo remota. Esto no es lo mismo que cualquiera de: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, o CVE-2021-21830. NOTA: Esta vulnerabilidad s\u00f3lo afecta a productos que ya no son soportados por el mantenedor" } ], "id": "CVE-2022-26507", "lastModified": "2024-11-21T06:54:04.920", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-04-14T13:15:11.637", "references": [ { "source": "cve@mitre.org", "tags": [ "Not Applicable", "Third Party Advisory" ], "url": "https://Claroty.com" }, { "source": "cve@mitre.org", "tags": [ "Mitigation", "Release Notes", "Third Party Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Not Applicable", "Third Party Advisory" ], "url": "https://Claroty.com" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mitigation", "Release Notes", "Third Party Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }