Vulnerabilites related to schneider-electric - remoteconnect
cve-2021-22797
Vulnerability from cvelistv5
Published
2022-03-28 16:25
Modified
2024-08-03 18:51
Severity ?
EPSS score ?
Summary
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior, including former Unity Pro), EcoStruxure Process Expert (2020 and prior, including former HDCS), SCADAPack RemoteConnect for x70 (All versions)
References
▼ | URL | Tags |
---|---|---|
https://www.se.com/ww/en/download/document/SEVD-2021-257-01/ | x_refsource_MISC |
Impacted products
Vendor | Product | Version | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Schneider Electric | EcoStruxure Control Expert |
Version: unspecified < V15.0 SP1 |
|||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.527Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2021-257-01/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "EcoStruxure Control Expert", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V15.0 SP1", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "EcoStruxure Process Expert", "vendor": "Schneider Electric", "versions": [ { "lessThan": "2020", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "SCADAPack RemoteConnect for x70", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior, including former Unity Pro), EcoStruxure Process Expert (2020 and prior, including former HDCS), SCADAPack RemoteConnect for x70 (All versions)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-22", "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-04-13T15:45:24", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2021-257-01/" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22797", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "EcoStruxure Control Expert", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "V15.0 SP1" } ] } }, { "product_name": "EcoStruxure Process Expert", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "2020" } ] } }, { "product_name": "SCADAPack RemoteConnect for x70", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Schneider Electric" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior, including former Unity Pro), EcoStruxure Process Expert (2020 and prior, including former HDCS), SCADAPack RemoteConnect for x70 (All versions)" } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.se.com/ww/en/download/document/SEVD-2021-257-01/", "refsource": "MISC", "url": "https://www.se.com/ww/en/download/document/SEVD-2021-257-01/" } ] }, "source": { "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22797", "datePublished": "2022-03-28T16:25:24", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.527Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-22782
Vulnerability from cvelistv5
Published
2021-07-14 14:26
Modified
2024-08-03 18:51
Severity ?
EPSS score ?
Summary
Missing Encryption of Sensitive Data vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause an information leak allowing disclosure of network and process information, credentials or intellectual property when an attacker can access a project file.
References
▼ | URL | Tags |
---|---|---|
http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions |
Version: EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.424Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions", "vendor": "n/a", "versions": [ { "status": "affected", "version": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions" } ] } ], "descriptions": [ { "lang": "en", "value": "Missing Encryption of Sensitive Data vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause an information leak allowing disclosure of network and process information, credentials or intellectual property when an attacker can access a project file." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-311", "description": "CWE-311: Missing Encryption of Sensitive Data", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-07-14T14:26:56", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22782", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions", "version": { "version_data": [ { "version_value": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Missing Encryption of Sensitive Data vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause an information leak allowing disclosure of network and process information, credentials or intellectual property when an attacker can access a project file." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-311: Missing Encryption of Sensitive Data" } ] } ] }, "references": { "reference_data": [ { "name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01", "refsource": "MISC", "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22782", "datePublished": "2021-07-14T14:26:56", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.424Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-22781
Vulnerability from cvelistv5
Published
2021-07-14 14:26
Modified
2024-08-03 18:51
Severity ?
EPSS score ?
Summary
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause a leak of SMTP credential used for mailbox authentication when an attacker can access a project file.
References
▼ | URL | Tags |
---|---|---|
http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions |
Version: EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.462Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions", "vendor": "n/a", "versions": [ { "status": "affected", "version": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions" } ] } ], "descriptions": [ { "lang": "en", "value": "Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause a leak of SMTP credential used for mailbox authentication when an attacker can access a project file." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-522", "description": "CWE-522: Insufficiently Protected Credentials ", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-07-14T14:26:51", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22781", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions", "version": { "version_data": [ { "version_value": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause a leak of SMTP credential used for mailbox authentication when an attacker can access a project file." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-522: Insufficiently Protected Credentials " } ] } ] }, "references": { "reference_data": [ { "name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01", "refsource": "MISC", "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22781", "datePublished": "2021-07-14T14:26:51", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.462Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-22780
Vulnerability from cvelistv5
Published
2021-07-14 14:26
Modified
2024-08-03 18:51
Severity ?
EPSS score ?
Summary
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause unauthorized access to a project file protected by a password when this file is shared with untrusted sources. An attacker may bypass the password protection and be able to view and modify a project file.
References
▼ | URL | Tags |
---|---|---|
http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions |
Version: EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.462Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions", "vendor": "n/a", "versions": [ { "status": "affected", "version": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions" } ] } ], "descriptions": [ { "lang": "en", "value": "Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause unauthorized access to a project file protected by a password when this file is shared with untrusted sources. An attacker may bypass the password protection and be able to view and modify a project file." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-522", "description": "CWE-522: Insufficiently Protected Credentials ", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-07-14T14:26:46", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22780", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions", "version": { "version_data": [ { "version_value": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause unauthorized access to a project file protected by a password when this file is shared with untrusted sources. An attacker may bypass the password protection and be able to view and modify a project file." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-522: Insufficiently Protected Credentials " } ] } ] }, "references": { "reference_data": [ { "name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01", "refsource": "MISC", "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22780", "datePublished": "2021-07-14T14:26:46", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.462Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-22779
Vulnerability from cvelistv5
Published
2021-07-14 14:26
Modified
2024-08-03 18:51
Severity ?
EPSS score ?
Summary
Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller.
References
▼ | URL | Tags |
---|---|---|
http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*) |
Version: EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*) |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.432Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*)", "vendor": "n/a", "versions": [ { "status": "affected", "version": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*)" } ] } ], "descriptions": [ { "lang": "en", "value": "Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-290", "description": "CWE-290: Authentication Bypass by Spoofing", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-07-14T14:26:41", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22779", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*)", "version": { "version_data": [ { "version_value": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*)" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-290: Authentication Bypass by Spoofing" } ] } ] }, "references": { "reference_data": [ { "name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01", "refsource": "MISC", "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22779", "datePublished": "2021-07-14T14:26:41", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.432Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-26507
Vulnerability from cvelistv5
Published
2022-04-14 12:04
Modified
2024-08-03 05:03
Severity ?
EPSS score ?
Summary
A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer
References
▼ | URL | Tags |
---|---|---|
https://Claroty.com | x_refsource_MISC | |
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02 | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T05:03:32.896Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://Claroty.com" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT\u0026T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer" } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-04-14T12:04:26", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://Claroty.com" }, { "tags": [ "x_refsource_MISC" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02" } ], "tags": [ "unsupported-when-assigned" ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2022-26507", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "** UNSUPPORTED WHEN ASSIGNED ** A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT\u0026T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://Claroty.com", "refsource": "MISC", "url": "https://Claroty.com" }, { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-26507", "datePublished": "2022-04-14T12:04:26", "dateReserved": "2022-03-06T00:00:00", "dateUpdated": "2024-08-03T05:03:32.896Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-22778
Vulnerability from cvelistv5
Published
2021-07-14 14:26
Modified
2024-08-03 18:51
Severity ?
EPSS score ?
Summary
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause protected derived function blocks to be read or modified by unauthorized users when accessing a project file.
References
▼ | URL | Tags |
---|---|---|
http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions |
Version: EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.378Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions", "vendor": "n/a", "versions": [ { "status": "affected", "version": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions" } ] } ], "descriptions": [ { "lang": "en", "value": "Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause protected derived function blocks to be read or modified by unauthorized users when accessing a project file." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-522", "description": "CWE-522: Insufficiently Protected Credentials ", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-07-14T14:26:35", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22778", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions", "version": { "version_data": [ { "version_value": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause protected derived function blocks to be read or modified by unauthorized users when accessing a project file." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-522: Insufficiently Protected Credentials " } ] } ] }, "references": { "reference_data": [ { "name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01", "refsource": "MISC", "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22778", "datePublished": "2021-07-14T14:26:35", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.378Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2021-07-14 15:15
Modified
2024-11-21 05:50
Severity ?
Summary
Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*", "matchCriteriaId": "43140BF9-455B-4E3C-BF5E-BB9BBF9802D2", "versionEndExcluding": "15.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.0:-:*:*:*:*:*:*", "matchCriteriaId": "A9BF2D84-901E-4D34-941F-FFAB85B0E9D3", "vulnerable": true }, { "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.0:sp1:*:*:*:*:*:*", "matchCriteriaId": "939C02B6-B5C5-4F87-8179-4AFFE13FCFD2", "vulnerable": true }, { "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_process_expert:*:*:*:*:*:*:*:*", "matchCriteriaId": "FD97669F-93D5-42C4-BFC4-1993867F5911", "vulnerable": true }, { "criteria": "cpe:2.3:a:schneider-electric:remoteconnect:*:*:*:*:*:*:scadapack_x70:*", "matchCriteriaId": "2D7E0B75-171E-4A73-B722-13473CE1B9D7", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m580_bmep581020_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "49646E6C-381F-495B-A5E8-8F522571D4AD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m580_bmep581020:-:*:*:*:*:*:*:*", "matchCriteriaId": "2317F260-7AA2-4178-B468-03DF36223E26", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m580_bmep581020h_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2F472ED1-8FE6-43BC-A4FF-E956D17ED427", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m580_bmep581020h:-:*:*:*:*:*:*:*", "matchCriteriaId": "3D7DDC42-37A1-43B0-AD46-2E0D098564BA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m580_bmep582020_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3F1315A8-FDEE-487F-BA66-A99745783911", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m580_bmep582020:-:*:*:*:*:*:*:*", "matchCriteriaId": "765E4FEE-255E-4C47-824A-5661B84B490B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m580_bmep582020h_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F543A095-B798-4C5B-A2B6-DF893191EAC3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m580_bmep582020h:-:*:*:*:*:*:*:*", "matchCriteriaId": "B1FEA377-3C45-4F88-B233-088A24BD0771", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m580_bmep582040_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "71823B23-C4E6-40EC-AC9C-2EABFDAFE498", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m580_bmep582040:-:*:*:*:*:*:*:*", "matchCriteriaId": "EBCCDD6D-35CE-4680-8B0C-86584B1D8958", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m580_bmep582040h_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3BDD13AD-681C-4C7D-82D5-3017FB3BE852", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m580_bmep582040h:-:*:*:*:*:*:*:*", "matchCriteriaId": "68FD5968-C522-4231-A98C-93D3101B6148", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m580_bmep582040s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B782A209-0612-4CA1-8438-6653D75F452C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m580_bmep582040s:-:*:*:*:*:*:*:*", "matchCriteriaId": "C02B27F6-B8CF-4D3B-9DA6-054F540EA6B6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m580_bmep583020_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "43B3DF32-480E-4CE1-9396-B33CD5F63A22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m580_bmep583020:-:*:*:*:*:*:*:*", "matchCriteriaId": "BBC38FF1-693E-4899-883C-1B7B80A52F2C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m580_bmep583040_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA09FB51-0FDC-4457-8ED6-A963CAB97DF4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m580_bmep583040:-:*:*:*:*:*:*:*", "matchCriteriaId": "002E7F33-6729-4C35-9DDA-7D8383BD5668", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m580_bmep584020_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A9C82569-7D6C-4FD9-B5BB-2E9576FDFB0E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m580_bmep584020:-:*:*:*:*:*:*:*", "matchCriteriaId": "47DFEBAC-2F1D-4870-8425-2199BF80B425", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m580_bmep584040_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DC98F7D-BDCC-4CF1-BA80-55EA68C5DDB5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m580_bmep584040:-:*:*:*:*:*:*:*", "matchCriteriaId": "FC4A1DF2-FF4C-4DBE-BF74-6A4A09E3DECE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m580_bmep584040s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CB7741EA-7955-4FC6-BE64-23EFBB0E3DC6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m580_bmep584040s:-:*:*:*:*:*:*:*", "matchCriteriaId": "6222C1F8-BE52-4666-B7F5-2E8BBC214F70", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m580_bmep585040_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "252FA576-D00F-4BF2-871D-291D209B443C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m580_bmep585040:-:*:*:*:*:*:*:*", "matchCriteriaId": "5376D9F4-8AFB-4909-A11B-33C54C4220DB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m580_bmep585040c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2786E51E-B042-4DEF-98CE-C46F381D468C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m580_bmep585040c:-:*:*:*:*:*:*:*", "matchCriteriaId": "CADB178B-FEFD-48A9-B155-0E8F6D490229", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m580_bmep586040_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D9E6C74-FAEE-49D3-807B-7F8416C12725", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m580_bmep586040:-:*:*:*:*:*:*:*", "matchCriteriaId": "6B3C1879-269B-47EB-891B-EF2E90C911D7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m580_bmep586040c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B182E938-6B50-4F3A-BAF6-AD2637E31E43", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m580_bmep586040c:-:*:*:*:*:*:*:*", "matchCriteriaId": "5771A1A5-3DAF-4869-A24F-F9B0A38B5DA5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8C610F17-FD8F-425E-A169-47EA7E6E8A0A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m580_bmeh582040:-:*:*:*:*:*:*:*", "matchCriteriaId": "F484F8BB-60B5-4045-92C3-0C2A0CD4107E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "355FFF2A-2B69-4340-AC49-257C0DC63B70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m580_bmeh582040c:-:*:*:*:*:*:*:*", "matchCriteriaId": "F4F0F823-89EA-451D-81DC-07AACA039371", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "777E63F4-CC75-4D68-98CC-896C58EBDD5A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m580_bmeh582040s:-:*:*:*:*:*:*:*", "matchCriteriaId": "610AE743-9FD1-4149-AD45-3B1DAE268BF9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BF0ACFD6-D1EE-4C25-A307-2E3FB67F4A20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m580_bmeh584040:-:*:*:*:*:*:*:*", "matchCriteriaId": "77116949-1141-432D-964B-29A759939E8F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AB46DD56-7A06-428C-97CB-E01C22BC8214", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m580_bmeh584040c:-:*:*:*:*:*:*:*", "matchCriteriaId": "B6CE23A2-09CC-4417-A45F-63BCA66C4DD8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "29482B31-563A-4931-B11E-FDE86F87F25E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m580_bmeh584040s:-:*:*:*:*:*:*:*", "matchCriteriaId": "97AAD857-95C0-4AE3-8510-CB306E8293F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1D261663-D224-4C92-A3F4-3509CAA78A36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m580_bmeh586040:-:*:*:*:*:*:*:*", "matchCriteriaId": "07E2FB94-F402-4CF0-BE35-574C1C6528BA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C6737F3-F881-4BDC-A4F4-F6F08B88EC1E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m580_bmeh586040c:-:*:*:*:*:*:*:*", "matchCriteriaId": "2E776EE9-A662-4068-A61A-62CAE23C87F7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CEBCF494-DC4C-4567-A5C8-2C8D93BAF289", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m580_bmeh586040s:-:*:*:*:*:*:*:*", "matchCriteriaId": "D53BD038-D594-41FF-B3EF-3365C5432AD0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m340_bmxp341000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8152BD1B-DB69-4BD0-9DD3-79FC059319B1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp341000:-:*:*:*:*:*:*:*", "matchCriteriaId": "178D2338-E48E-493C-992F-337AACE794DE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342010_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4A4A2D03-6D4E-4ED9-A0CE-3DD681CB6E9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp342010:-:*:*:*:*:*:*:*", "matchCriteriaId": "833B2455-5D39-4457-9D6F-0CD738A2EB02", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342020_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C747D719-51A2-44F5-B940-89D84437DA95", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp342020:-:*:*:*:*:*:*:*", "matchCriteriaId": "99F2F851-C18F-4CB8-B47C-516F2AC7955D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342030_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "34CC8BAD-3D4F-4DAD-B8CE-09D0BF4A5E11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp342030:-:*:*:*:*:*:*:*", "matchCriteriaId": "E472ABB0-5556-4B96-9CEF-2180E24FA7FD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller." }, { "lang": "es", "value": "Se presenta una vulnerabilidad de Omisi\u00f3n de Autenticaci\u00f3n por Spoofing en EcoStruxure Control Expert (todas las versiones anteriores a V15.0 SP1, incluyendo todas las versiones de Unity Pro), EcoStruxure Control Expert versi\u00f3n V15.0 SP1, EcoStruxure Process Expert (todas las versiones, incluyendo todas las versiones de EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (todas las versiones), Modicon M580 CPU (todas las versiones - n\u00fameros de parte BMEP* y BMEH*), Modicon M340 CPU (todas las versiones - n\u00fameros de parte BMXP34*), que podr\u00eda causar un acceso no autorizado en modo de lectura y escritura al controlador mediante el spoofing de la comunicaci\u00f3n Modbus entre el software de ingenier\u00eda y el controlador" } ], "id": "CVE-2021-22779", "lastModified": "2024-11-21T05:50:38.990", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 6.4, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 4.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.2, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-07-14T15:15:08.240", "references": [ { "source": "cybersecurity@se.com", "tags": [ "Vendor Advisory" ], "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01" } ], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-290" } ], "source": "cybersecurity@se.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-07-14 15:15
Modified
2024-11-21 05:50
Severity ?
Summary
Missing Encryption of Sensitive Data vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause an information leak allowing disclosure of network and process information, credentials or intellectual property when an attacker can access a project file.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
schneider-electric | ecostruxure_control_expert | * | |
schneider-electric | ecostruxure_control_expert | 15.0 | |
schneider-electric | ecostruxure_process_expert | * | |
schneider-electric | remoteconnect | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*", "matchCriteriaId": "43140BF9-455B-4E3C-BF5E-BB9BBF9802D2", "versionEndExcluding": "15.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.0:-:*:*:*:*:*:*", "matchCriteriaId": "A9BF2D84-901E-4D34-941F-FFAB85B0E9D3", "vulnerable": true }, { "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_process_expert:*:*:*:*:*:*:*:*", "matchCriteriaId": "FD97669F-93D5-42C4-BFC4-1993867F5911", "vulnerable": true }, { "criteria": "cpe:2.3:a:schneider-electric:remoteconnect:*:*:*:*:*:*:scadapack_x70:*", "matchCriteriaId": "2D7E0B75-171E-4A73-B722-13473CE1B9D7", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Missing Encryption of Sensitive Data vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause an information leak allowing disclosure of network and process information, credentials or intellectual property when an attacker can access a project file." }, { "lang": "es", "value": "Se presenta una vulnerabilidad de falta de encriptaci\u00f3n de datos confidenciales en EcoStruxure Control Expert (todas las versiones anteriores a V15.0 SP1, incluyendo todas las versiones de Unity Pro), EcoStruxure Process Expert (todas las versiones, incluyendo todas las versiones de EcoStruxure Hybrid DCS), y SCADAPack RemoteConnect for x70, todas las versiones, que podr\u00eda causar una filtraci\u00f3n de informaci\u00f3n permitiendo la divulgaci\u00f3n de informaci\u00f3n de red y de proceso, credenciales o propiedad intelectual cuando un atacante puede acceder a un archivo de proyecto" } ], "id": "CVE-2021-22782", "lastModified": "2024-11-21T05:50:39.393", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 2.1, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-07-14T15:15:08.447", "references": [ { "source": "cybersecurity@se.com", "tags": [ "Vendor Advisory" ], "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01" } ], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-311" } ], "source": "cybersecurity@se.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2022-04-13 16:15
Modified
2024-11-21 05:50
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior, including former Unity Pro), EcoStruxure Process Expert (2020 and prior, including former HDCS), SCADAPack RemoteConnect for x70 (All versions)
References
▼ | URL | Tags | |
---|---|---|---|
cybersecurity@se.com | https://www.se.com/ww/en/download/document/SEVD-2021-257-01/ | Mitigation, Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.se.com/ww/en/download/document/SEVD-2021-257-01/ | Mitigation, Patch, Vendor Advisory |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*", "matchCriteriaId": "8DCC0C29-32C2-4463-B98F-AB4B56FF5314", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_process_expert:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAB4A9EC-96A2-424D-A858-162E662EBEFB", "versionEndExcluding": "2021", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:remoteconnect:-:*:*:*:*:*:*:*", "matchCriteriaId": "3FFDF36B-30A5-4B35-956C-60DC15CE7EE4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:scadapack_470:-:*:*:*:*:*:*:*", "matchCriteriaId": "F51A7887-4F1A-428C-9E68-260E7262A678", "vulnerable": false }, { "criteria": "cpe:2.3:h:schneider-electric:scadapack_474:-:*:*:*:*:*:*:*", "matchCriteriaId": "58BACC54-6609-4DCE-AEEC-A9C2396635A0", "vulnerable": false }, { "criteria": "cpe:2.3:h:schneider-electric:scadapack_570:-:*:*:*:*:*:*:*", "matchCriteriaId": "FFDF44F3-2514-4CB0-A1A4-87123225B0F1", "vulnerable": false }, { "criteria": "cpe:2.3:h:schneider-electric:scadapack_574:-:*:*:*:*:*:*:*", "matchCriteriaId": "4F5CDC99-C4C8-43FE-8EA7-65C7EDFD9BA3", "vulnerable": false }, { "criteria": "cpe:2.3:h:schneider-electric:scadapack_575:-:*:*:*:*:*:*:*", "matchCriteriaId": "DE4172DF-94E3-4AEE-8D6B-9F48DC453B9E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior, including former Unity Pro), EcoStruxure Process Expert (2020 and prior, including former HDCS), SCADAPack RemoteConnect for x70 (All versions)" }, { "lang": "es", "value": "Una CWE-22: Se presenta una vulnerabilidad de Limitaci\u00f3n inadecuada de un nombre de ruta a un directorio restringido (\" Salto de Ruta\") que podr\u00eda causar la implementaci\u00f3n de scripts maliciosos en una ubicaci\u00f3n no autorizada y puede resultar en una ejecuci\u00f3n de c\u00f3digo en la estaci\u00f3n de trabajo de ingenier\u00eda cuando es cargado un archivo de proyecto malicioso en el software de ingenier\u00eda. Producto afectado: EcoStruxure Control Expert (versiones V15.0 SP1 y anteriores, incluido el antiguo Unity Pro), EcoStruxure Process Expert (versiones 2020 y anteriores, incluido el antiguo HDCS), SCADAPack RemoteConnect para x70 (Todas las versiones)" } ], "id": "CVE-2021-22797", "lastModified": "2024-11-21T05:50:41.417", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "cybersecurity@se.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-04-13T16:15:09.370", "references": [ { "source": "cybersecurity@se.com", "tags": [ "Mitigation", "Patch", "Vendor Advisory" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2021-257-01/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mitigation", "Patch", "Vendor Advisory" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2021-257-01/" } ], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-22" } ], "source": "cybersecurity@se.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-07-14 15:15
Modified
2024-11-21 05:50
Severity ?
Summary
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause protected derived function blocks to be read or modified by unauthorized users when accessing a project file.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
schneider-electric | ecostruxure_control_expert | * | |
schneider-electric | ecostruxure_control_expert | 15.0 | |
schneider-electric | ecostruxure_process_expert | * | |
schneider-electric | remoteconnect | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*", "matchCriteriaId": "43140BF9-455B-4E3C-BF5E-BB9BBF9802D2", "versionEndExcluding": "15.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.0:-:*:*:*:*:*:*", "matchCriteriaId": "A9BF2D84-901E-4D34-941F-FFAB85B0E9D3", "vulnerable": true }, { "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_process_expert:*:*:*:*:*:*:*:*", "matchCriteriaId": "FD97669F-93D5-42C4-BFC4-1993867F5911", "vulnerable": true }, { "criteria": "cpe:2.3:a:schneider-electric:remoteconnect:*:*:*:*:*:*:scadapack_x70:*", "matchCriteriaId": "2D7E0B75-171E-4A73-B722-13473CE1B9D7", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause protected derived function blocks to be read or modified by unauthorized users when accessing a project file." }, { "lang": "es", "value": "Se presenta una vulnerabilidad de credenciales insuficientemente protegidas en EcoStruxure Control Expert (todas las versiones anteriores a V15.0 SP1, incluy\u00e9ndo todas las versiones de Unity Pro), EcoStruxure Process Expert (todas las versiones, incluy\u00e9ndo todas las versiones de EcoStruxure Hybrid DCS) y SCADAPack RemoteConnect for x70, todas las versiones, que podr\u00eda causar una lectura o modificaci\u00f3n de bloques de funci\u00f3n derivados protegidos por parte de usuarios no autorizados cuando se accede a un archivo de proyecto" } ], "id": "CVE-2021-22778", "lastModified": "2024-11-21T05:50:38.877", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 3.6, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 4.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.2, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-07-14T15:15:08.173", "references": [ { "source": "cybersecurity@se.com", "tags": [ "Vendor Advisory" ], "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01" } ], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-522" } ], "source": "cybersecurity@se.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2022-04-14 13:15
Modified
2024-11-21 06:54
Severity ?
Summary
A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://Claroty.com | Not Applicable, Third Party Advisory | |
cve@mitre.org | https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02 | Mitigation, Release Notes, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://Claroty.com | Not Applicable, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02 | Mitigation, Release Notes, Third Party Advisory |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:att:xmill:0.7:*:*:*:*:*:*:*", "matchCriteriaId": "4CC987F6-AAFA-4CDE-842D-EA7858A3E7F4", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*", "matchCriteriaId": "8DCC0C29-32C2-4463-B98F-AB4B56FF5314", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "78F6B1CC-488B-48E8-B96B-77A1894E9E92", "vulnerable": true }, { "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_process_expert:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAB4A9EC-96A2-424D-A858-162E662EBEFB", "versionEndExcluding": "2021", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:remoteconnect:-:*:*:*:*:*:*:*", "matchCriteriaId": "3FFDF36B-30A5-4B35-956C-60DC15CE7EE4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:scadapack_470:-:*:*:*:*:*:*:*", "matchCriteriaId": "F51A7887-4F1A-428C-9E68-260E7262A678", "vulnerable": false }, { "criteria": "cpe:2.3:h:schneider-electric:scadapack_474:-:*:*:*:*:*:*:*", "matchCriteriaId": "58BACC54-6609-4DCE-AEEC-A9C2396635A0", "vulnerable": false }, { "criteria": "cpe:2.3:h:schneider-electric:scadapack_570:-:*:*:*:*:*:*:*", "matchCriteriaId": "FFDF44F3-2514-4CB0-A1A4-87123225B0F1", "vulnerable": false }, { "criteria": "cpe:2.3:h:schneider-electric:scadapack_574:-:*:*:*:*:*:*:*", "matchCriteriaId": "4F5CDC99-C4C8-43FE-8EA7-65C7EDFD9BA3", "vulnerable": false }, { "criteria": "cpe:2.3:h:schneider-electric:scadapack_575:-:*:*:*:*:*:*:*", "matchCriteriaId": "DE4172DF-94E3-4AEE-8D6B-9F48DC453B9E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [ { "sourceIdentifier": "cve@mitre.org", "tags": [ "unsupported-when-assigned" ] } ], "descriptions": [ { "lang": "en", "value": "A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT\u0026T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer" }, { "lang": "es", "value": "** NO SOPORTADO CUANDO SE ASIGN\u00d3 ** Se presenta un desbordamiento de b\u00fafer en la regi\u00f3n heap de la memoria en XML Decompression DecodeTreeBlock en AT\u0026amp;T Labs Xmill versi\u00f3n 0.7. Un archivo de entrada dise\u00f1ado puede conllevar a una ejecuci\u00f3n de c\u00f3digo remota. Esto no es lo mismo que cualquiera de: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, o CVE-2021-21830. NOTA: Esta vulnerabilidad s\u00f3lo afecta a productos que ya no son soportados por el mantenedor" } ], "id": "CVE-2022-26507", "lastModified": "2024-11-21T06:54:04.920", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-04-14T13:15:11.637", "references": [ { "source": "cve@mitre.org", "tags": [ "Not Applicable", "Third Party Advisory" ], "url": "https://Claroty.com" }, { "source": "cve@mitre.org", "tags": [ "Mitigation", "Release Notes", "Third Party Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Not Applicable", "Third Party Advisory" ], "url": "https://Claroty.com" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mitigation", "Release Notes", "Third Party Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-07-14 15:15
Modified
2024-11-21 05:50
Severity ?
Summary
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause a leak of SMTP credential used for mailbox authentication when an attacker can access a project file.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
schneider-electric | ecostruxure_control_expert | * | |
schneider-electric | ecostruxure_control_expert | 15.0 | |
schneider-electric | ecostruxure_process_expert | * | |
schneider-electric | remoteconnect | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*", "matchCriteriaId": "43140BF9-455B-4E3C-BF5E-BB9BBF9802D2", "versionEndExcluding": "15.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.0:-:*:*:*:*:*:*", "matchCriteriaId": "A9BF2D84-901E-4D34-941F-FFAB85B0E9D3", "vulnerable": true }, { "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_process_expert:*:*:*:*:*:*:*:*", "matchCriteriaId": "FD97669F-93D5-42C4-BFC4-1993867F5911", "vulnerable": true }, { "criteria": "cpe:2.3:a:schneider-electric:remoteconnect:*:*:*:*:*:*:scadapack_x70:*", "matchCriteriaId": "2D7E0B75-171E-4A73-B722-13473CE1B9D7", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause a leak of SMTP credential used for mailbox authentication when an attacker can access a project file." }, { "lang": "es", "value": "Se presenta una vulnerabilidad de credenciales insuficientemente protegidas en EcoStruxure Control Expert (todas las versiones anteriores a V15.0 SP1, incluidas todas las versiones de Unity Pro), EcoStruxure Process Expert (todas las versiones, incluidas todas las versiones de EcoStruxure Hybrid DCS) y SCADAPack RemoteConnect for x70, todas las versiones, que podr\u00eda causar una filtraci\u00f3n de credenciales SMTP usadas para la autenticaci\u00f3n del buz\u00f3n cuando un atacante puede acceder a un archivo de proyecto" } ], "id": "CVE-2021-22781", "lastModified": "2024-11-21T05:50:39.270", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 2.1, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-07-14T15:15:08.377", "references": [ { "source": "cybersecurity@se.com", "tags": [ "Vendor Advisory" ], "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01" } ], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-522" } ], "source": "cybersecurity@se.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-522" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-07-14 15:15
Modified
2024-11-21 05:50
Severity ?
Summary
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause unauthorized access to a project file protected by a password when this file is shared with untrusted sources. An attacker may bypass the password protection and be able to view and modify a project file.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
schneider-electric | ecostruxure_control_expert | * | |
schneider-electric | ecostruxure_control_expert | 15.0 | |
schneider-electric | ecostruxure_process_expert | * | |
schneider-electric | remoteconnect | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*", "matchCriteriaId": "43140BF9-455B-4E3C-BF5E-BB9BBF9802D2", "versionEndExcluding": "15.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.0:-:*:*:*:*:*:*", "matchCriteriaId": "A9BF2D84-901E-4D34-941F-FFAB85B0E9D3", "vulnerable": true }, { "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_process_expert:*:*:*:*:*:*:*:*", "matchCriteriaId": "FD97669F-93D5-42C4-BFC4-1993867F5911", "vulnerable": true }, { "criteria": "cpe:2.3:a:schneider-electric:remoteconnect:*:*:*:*:*:*:scadapack_x70:*", "matchCriteriaId": "2D7E0B75-171E-4A73-B722-13473CE1B9D7", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause unauthorized access to a project file protected by a password when this file is shared with untrusted sources. An attacker may bypass the password protection and be able to view and modify a project file." }, { "lang": "es", "value": "Se presenta una vulnerabilidad de Credenciales Insuficientemente Protegidas en EcoStruxure Control Expert (todas las versiones anteriores a V15.0 SP1, incluyendo todas las versiones de Unity Pro), EcoStruxure Process Expert (todas las versiones, incluyendo todas las versiones de EcoStruxure Hybrid DCS), y SCADAPack RemoteConnect for x70, todas las versiones, que podr\u00eda causar un acceso no autorizado a un archivo de proyecto protegido por una contrase\u00f1a cuando este archivo se comparte con fuentes no confiables. Un atacante podr\u00eda omitir la protecci\u00f3n por contrase\u00f1a y ser capaz de visualizar y modificar un archivo de proyecto" } ], "id": "CVE-2021-22780", "lastModified": "2024-11-21T05:50:39.147", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 3.6, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 4.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.2, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-07-14T15:15:08.307", "references": [ { "source": "cybersecurity@se.com", "tags": [ "Vendor Advisory" ], "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01" } ], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-522" } ], "source": "cybersecurity@se.com", "type": "Primary" } ] }