Vulnerabilites related to netgear - rbk853
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk842_firmware | * | |
netgear | rbk842 | - | |
netgear | rbr840_firmware | * | |
netgear | rbr840 | - | |
netgear | rbs840_firmware | * | |
netgear | rbs840 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436BED04-0FD2-499B-9D42-F9E0AAA6CB97", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F35DDDEC-A64B-400E-ABF8-E13F432BD261", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "754ACE12-E256-4B21-ABD5-CB5F3DA4BDC7", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D19A1E4D-30F2-4263-B4BE-273EED14702E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44ED0285-F862-44B9-B0EE-C2FDC42706A2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A553C5A2-EB80-4314-A623-8F489A4E74E2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK842 versiones anteriores a 3.2.15.25, RBR840 versiones anteriores a 3.2.15.25, RBS840 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBK853 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25 y RBS850 versiones anteriores a 3.2.15.25" } ], "id": "CVE-2020-14440", "lastModified": "2024-11-21T05:03:16.930", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-18T17:15:13.140", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061943/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0065" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061943/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0065" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:L/A:L
Vendor | Product | Version | |
---|---|---|---|
netgear | rbw30_firmware | * | |
netgear | rbw30 | - | |
netgear | rbs40v_firmware | * | |
netgear | rbs40v | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbk754_firmware | * | |
netgear | rbk754 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbk854_firmware | * | |
netgear | rbk854 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6F388398-842E-40B1-9ACC-2D9A15D2BF2A", "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E2240C06-A117-48E6-9576-C58F3314A160", "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436BED04-0FD2-499B-9D42-F9E0AAA6CB97", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F35DDDEC-A64B-400E-ABF8-E13F432BD261", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk754_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "13C16392-F041-4A90-90C0-C291C0CD545E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk754:-:*:*:*:*:*:*:*", "matchCriteriaId": "F8BF464E-63DB-4AC4-9B5D-E3ECDC000305", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A553C5A2-EB80-4314-A623-8F489A4E74E2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C76041B8-E676-4E29-BE18-E1B9C4735D5C", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "matchCriteriaId": "01D12702-8B86-419C-8636-1259FD2D5844", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects RBW30 before 2.6.1.4, RBS40V before 2.6.1.4, RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBK754 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBK854 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una divulgaci\u00f3n de informaci\u00f3n confidencial.\u0026#xa0;Esto afecta a RBW30 versiones anteriores a 2.6.1.4, RBS40V versiones anteriores a 2.6.1.4, RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBK754 versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores al 3.2.15.25, RBK853 versiones anteriores al 3.2.15.25, RBK854 versiones anteriores al 3.2.15.25, RBR850 versiones anteriores al 3.2.15.25 y RBS850 versiones anteriores al 3.2.15.25" } ], "id": "CVE-2021-29082", "lastModified": "2024-11-21T06:00:40.660", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:L/A:L", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.3, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-23T07:15:14.390", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063005/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-WiFi-Systems-PSV-2020-0037" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063005/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-WiFi-Systems-PSV-2020-0037" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.6 (Critical) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbw30_firmware | * | |
netgear | rbw30 | - | |
netgear | rbs40v_firmware | * | |
netgear | rbs40v | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbk854_firmware | * | |
netgear | rbk854 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbk754_firmware | * | |
netgear | rbk754 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8EF8E22-9DC7-4A42-99E0-A6822F647DF7", "versionEndExcluding": "2.6.2.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1CA086E1-DB23-4130-B746-D56F5A188C3B", "versionEndExcluding": "2.6.2.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "64DF0B69-B591-47B6-88C1-82544AA3DE9B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "106863FF-9BE9-4C18-9A86-C458FF9EBDD6", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "matchCriteriaId": "01D12702-8B86-419C-8636-1259FD2D5844", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E1723D5F-FFDB-4E4D-80B7-4B28598D5895", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D041B9F-37E4-48A9-9841-85EFFF7FA1D1", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk754_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E6E6FDC1-BB17-454A-9B3A-5FB1F705C56B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk754:-:*:*:*:*:*:*:*", "matchCriteriaId": "F8BF464E-63DB-4AC4-9B5D-E3ECDC000305", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBW30 before 2.6.2.2, RBS40V before 2.6.2.4, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a RBW30 versiones anteriores a 2.6.2.2, RBS40V versiones anteriores a 2.6.2.4, RBK852 versiones anteriores a 3.2.17.12, RBK853 versiones anteriores a 3.2.17.12, RBK854 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3. 2.17.12, RBK752 versiones anteriores a 3.2.17.12, RBK753 versiones anteriores a 3.2.17.12, RBK753S versiones anteriores a 3.2.17.12, RBK754 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12 y RBS750 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-29077", "lastModified": "2024-11-21T06:00:39.877", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-23T07:15:14.013", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063016/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0486" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063016/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0486" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.6 (Critical) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbk854_firmware | * | |
netgear | rbk854 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "64DF0B69-B591-47B6-88C1-82544AA3DE9B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "106863FF-9BE9-4C18-9A86-C458FF9EBDD6", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "matchCriteriaId": "01D12702-8B86-419C-8636-1259FD2D5844", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una omisi\u00f3n de autenticaci\u00f3n. Esto afecta al RBK852 versiones anteriores a 3.2.17.12, al RBK853 versiones anteriores a 3.2.17.12, al RBK854 versiones anteriores a 3.2.17.12, al RBR850 versiones anteriores a 3.2.17.12 y al RBS850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-29066", "lastModified": "2024-11-21T06:00:37.963", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-23T07:15:13.157", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063014/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0484" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063014/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0484" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk842_firmware | * | |
netgear | rbk842 | - | |
netgear | rbr840_firmware | * | |
netgear | rbr840 | - | |
netgear | rbs840_firmware | * | |
netgear | rbs840 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436BED04-0FD2-499B-9D42-F9E0AAA6CB97", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F35DDDEC-A64B-400E-ABF8-E13F432BD261", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "754ACE12-E256-4B21-ABD5-CB5F3DA4BDC7", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D19A1E4D-30F2-4263-B4BE-273EED14702E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44ED0285-F862-44B9-B0EE-C2FDC42706A2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A553C5A2-EB80-4314-A623-8F489A4E74E2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK842 versiones anteriores a 3.2.15.25, RBR840 versiones anteriores a 3.2.15.25, RBS840 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBK853 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25 y RBS850 versiones anteriores a 3.2.15.25" } ], "id": "CVE-2020-14442", "lastModified": "2024-11-21T05:03:17.260", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-18T17:15:13.327", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061947/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0103" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061947/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0103" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk842_firmware | * | |
netgear | rbk842 | - | |
netgear | rbr840_firmware | * | |
netgear | rbr840 | - | |
netgear | rbs840_firmware | * | |
netgear | rbs840 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436BED04-0FD2-499B-9D42-F9E0AAA6CB97", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F35DDDEC-A64B-400E-ABF8-E13F432BD261", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "754ACE12-E256-4B21-ABD5-CB5F3DA4BDC7", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D19A1E4D-30F2-4263-B4BE-273EED14702E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44ED0285-F862-44B9-B0EE-C2FDC42706A2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A553C5A2-EB80-4314-A623-8F489A4E74E2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una divulgaci\u00f3n de credenciales administrativas. Esto afecta a RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK842 versiones anteriores a 3.2.15.25, RBR840 versiones anteriores a 3.2.15.25, RBS840 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBK853 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25 y RBS850 versiones anteriores a 3.2.15.25" } ], "id": "CVE-2020-14427", "lastModified": "2024-11-21T05:03:14.637", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-18T17:15:11.920", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061935/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0042" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061935/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0042" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk842_firmware | * | |
netgear | rbk842 | - | |
netgear | rbr840_firmware | * | |
netgear | rbr840 | - | |
netgear | rbs840_firmware | * | |
netgear | rbs840 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436BED04-0FD2-499B-9D42-F9E0AAA6CB97", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F35DDDEC-A64B-400E-ABF8-E13F432BD261", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "754ACE12-E256-4B21-ABD5-CB5F3DA4BDC7", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D19A1E4D-30F2-4263-B4BE-273EED14702E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44ED0285-F862-44B9-B0EE-C2FDC42706A2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A553C5A2-EB80-4314-A623-8F489A4E74E2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK842 versiones anteriores a 3.2.15.25, RBR840 versiones anteriores a 3.2.15.25, RBS840 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBK853 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25 y RBS850 versiones anteriores a 3.2.15.25" } ], "id": "CVE-2020-14438", "lastModified": "2024-11-21T05:03:16.597", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-18T17:15:12.953", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061941/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0063" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061941/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0063" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.6 (Critical) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbk854_firmware | * | |
netgear | rbk854 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "64DF0B69-B591-47B6-88C1-82544AA3DE9B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "106863FF-9BE9-4C18-9A86-C458FF9EBDD6", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "matchCriteriaId": "01D12702-8B86-419C-8636-1259FD2D5844", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a RBK852 versiones anteriores a 3.2.17.12, RBK853 versiones anteriores a 3.2.17.12, RBK854 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-29076", "lastModified": "2024-11-21T06:00:39.723", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-23T07:15:13.920", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063015/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0485" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063015/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0485" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.4 (High) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbk854_firmware | * | |
netgear | rbk854 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "64DF0B69-B591-47B6-88C1-82544AA3DE9B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "106863FF-9BE9-4C18-9A86-C458FF9EBDD6", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "matchCriteriaId": "01D12702-8B86-419C-8636-1259FD2D5844", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autentificado. Esto afecta a RBK852 versiones anteriores a 3.2.17.12, RBK853 versiones anteriores a 3.2.17.12, RBK854 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-29070", "lastModified": "2024-11-21T06:00:38.747", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-23T07:15:13.483", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063019/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Routers-PSV-2020-0530" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063019/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Routers-PSV-2020-0530" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbk842_firmware | * | |
netgear | rbk842 | - | |
netgear | rbr840_firmware | * | |
netgear | rbr840 | - | |
netgear | rbs840_firmware | * | |
netgear | rbs840 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436BED04-0FD2-499B-9D42-F9E0AAA6CB97", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F35DDDEC-A64B-400E-ABF8-E13F432BD261", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "971A9859-C378-4DEC-9432-364930E662B7", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "003185A9-52A8-42BB-A898-CE9F020AC301", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0B05A46-1FD0-4F51-857C-DA4F838C1A87", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D842A92-6063-4CF5-B73B-2FD9FCE4225A", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "28A22215-3A55-44B2-906D-10518A24F83C", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "894527F8-4315-4CF0-A3D5-EACC612E0318", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C1C6098D-779F-4807-988F-90103E312896", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBK853 before 3.2.10.11, RBR850 before 3.2.10.11, RBS850 before 3.2.10.11, RBK842 before 3.2.10.11, RBR840 before 3.2.10.11, and RBS840 before 3.2.10.11." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una divulgaci\u00f3n de credenciales administrativas. Esto afecta a RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.10.11, RBK853 versiones anteriores a 3.2.10.11, RBR850 versiones anteriores a 3.2.10.11, RBS850 versiones anteriores a 3.2.10.11, RBK842 versiones anteriores a 3.2.10.11, RBR840 versiones anteriores a 3.2.10.11 y RBS840 versiones anteriores a 3.2.10.11" } ], "id": "CVE-2020-14426", "lastModified": "2024-11-21T05:03:14.453", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-18T17:15:11.813", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061931/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-Wifi-Systems-PSV-2020-0033" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061931/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-Wifi-Systems-PSV-2020-0033" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk842_firmware | * | |
netgear | rbk842 | - | |
netgear | rbr840_firmware | * | |
netgear | rbr840 | - | |
netgear | rbs840_firmware | * | |
netgear | rbs840 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436BED04-0FD2-499B-9D42-F9E0AAA6CB97", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F35DDDEC-A64B-400E-ABF8-E13F432BD261", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "754ACE12-E256-4B21-ABD5-CB5F3DA4BDC7", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D19A1E4D-30F2-4263-B4BE-273EED14702E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44ED0285-F862-44B9-B0EE-C2FDC42706A2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A553C5A2-EB80-4314-A623-8F489A4E74E2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una divulgaci\u00f3n de credenciales administrativas. Esto afecta a RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK842 versiones anteriores a 3.2.15.25, RBR840 versiones anteriores a 3.2.15.25, RBS840 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBK853 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25 y RBS850 versiones anteriores a 3.2.15.25" } ], "id": "CVE-2020-14430", "lastModified": "2024-11-21T05:03:15.150", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-18T17:15:12.170", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061939/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0051" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061939/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0051" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbk842_firmware | * | |
netgear | rbk842 | - | |
netgear | rbr840_firmware | * | |
netgear | rbr840 | - | |
netgear | rbs840_firmware | * | |
netgear | rbs840 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436BED04-0FD2-499B-9D42-F9E0AAA6CB97", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F35DDDEC-A64B-400E-ABF8-E13F432BD261", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A553C5A2-EB80-4314-A623-8F489A4E74E2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "754ACE12-E256-4B21-ABD5-CB5F3DA4BDC7", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D19A1E4D-30F2-4263-B4BE-273EED14702E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44ED0285-F862-44B9-B0EE-C2FDC42706A2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, and RBS840 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBK853 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25, RBS850 versiones anteriores a 3.2.15.25, RBK842 versiones anteriores a 3.2.15.25, RBR840 versiones anteriores a 3.2.15.25 y RBS840 versiones anteriores a 3.2.15.25" } ], "id": "CVE-2020-14436", "lastModified": "2024-11-21T05:03:16.207", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-18T17:15:12.750", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061933/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0039" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061933/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0039" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.0 (Critical) - CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbk854_firmware | * | |
netgear | rbk854 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbr752_firmware | * | |
netgear | rbr752 | - | |
netgear | rbr753_firmware | * | |
netgear | rbr753 | - | |
netgear | rbr753s_firmware | * | |
netgear | rbr753s | - | |
netgear | rbr754_firmware | * | |
netgear | rbr754 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "64DF0B69-B591-47B6-88C1-82544AA3DE9B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "106863FF-9BE9-4C18-9A86-C458FF9EBDD6", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "matchCriteriaId": "01D12702-8B86-419C-8636-1259FD2D5844", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CCE2E74C-7472-41C9-B48B-4F6D09819694", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr752:-:*:*:*:*:*:*:*", "matchCriteriaId": "7A727637-4CB0-4CDF-86D6-91B72E8F1A67", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1B8A2AE8-D24F-4FE9-BCB5-629F879CD921", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr753:-:*:*:*:*:*:*:*", "matchCriteriaId": "749C2A47-CC43-433F-8FC7-EAC9853E32AB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "725B56D3-FE36-4A77-B723-A7A3D8DD0443", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "C08A0E20-90A3-4D49-8E06-97944C3EF312", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr754_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EAC29540-B53A-4033-B998-8E6BAB033FF5", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr754:-:*:*:*:*:*:*:*", "matchCriteriaId": "DE7FE0A5-16D7-4AEC-A3B1-940F44E5492F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBR752 before 3.2.17.12, RBR753 before 3.2.17.12, RBR753S before 3.2.17.12, RBR754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autentificado. Esto afecta a RBK852 versiones anteriores a 3.2.17.12, RBK853 versiones anteriores a 3.2.17.12, RBK854 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3.2.17.12, RBR752 versiones anteriores a 3. 2.17.12, RBR753 versiones anteriores a 3.2.17.12, RBR753S versiones anteriores a 3.2.17.12, RBR754 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12 y RBS750 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-29071", "lastModified": "2024-11-21T06:00:38.910", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.0, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.3, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-23T07:15:13.560", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063008/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0476" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063008/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0476" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbk842_firmware | * | |
netgear | rbk842 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbr840_firmware | * | |
netgear | rbr840 | - | |
netgear | rbs840_firmware | * | |
netgear | rbs840 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A553C5A2-EB80-4314-A623-8F489A4E74E2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "754ACE12-E256-4B21-ABD5-CB5F3DA4BDC7", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D19A1E4D-30F2-4263-B4BE-273EED14702E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44ED0285-F862-44B9-B0EE-C2FDC42706A2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436BED04-0FD2-499B-9D42-F9E0AAA6CB97", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F35DDDEC-A64B-400E-ABF8-E13F432BD261", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBK842 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, and RBS750 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK852 versiones anteriores a 3.2.15.25, RBK853 versiones anteriores a 3.2.15.25, RBK842 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25, RBS850 versiones anteriores a 3.2.15.25, RBR840 versiones anteriores a 3.2.15.25, RBS840 versiones anteriores a 3.2.15.25, RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25 y RBS750 versiones anteriores a 3.2.15.25" } ], "id": "CVE-2020-14433", "lastModified": "2024-11-21T05:03:15.677", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-18T17:15:12.453", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061932/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0035" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061932/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0035" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbk842_firmware | * | |
netgear | rbk842 | - | |
netgear | rbr840_firmware | * | |
netgear | rbr840 | - | |
netgear | rbs840_firmware | * | |
netgear | rbs840 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436BED04-0FD2-499B-9D42-F9E0AAA6CB97", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F35DDDEC-A64B-400E-ABF8-E13F432BD261", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A553C5A2-EB80-4314-A623-8F489A4E74E2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "754ACE12-E256-4B21-ABD5-CB5F3DA4BDC7", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D19A1E4D-30F2-4263-B4BE-273EED14702E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44ED0285-F862-44B9-B0EE-C2FDC42706A2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, and RBS840 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBK853 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25, RBS850 versiones anteriores a 3.2.15.25, RBK842 versiones anteriores a 3.2.15.25, RBR840 versiones anteriores a 3.2.15.25 y RBS840 versiones anteriores a 3.2.15.25" } ], "id": "CVE-2020-14434", "lastModified": "2024-11-21T05:03:15.850", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 7.7, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:A/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-18T17:15:12.547", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061934/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0040" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061934/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0040" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk842_firmware | * | |
netgear | rbk842 | - | |
netgear | rbr840_firmware | * | |
netgear | rbr840 | - | |
netgear | rbs840_firmware | * | |
netgear | rbs840 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436BED04-0FD2-499B-9D42-F9E0AAA6CB97", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F35DDDEC-A64B-400E-ABF8-E13F432BD261", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "754ACE12-E256-4B21-ABD5-CB5F3DA4BDC7", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D19A1E4D-30F2-4263-B4BE-273EED14702E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44ED0285-F862-44B9-B0EE-C2FDC42706A2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A553C5A2-EB80-4314-A623-8F489A4E74E2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK842 versiones anteriores a 3.2.15.25, RBR840 versiones anteriores a 3.2.15.25, RBS840 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBK853 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25 y RBS850 versiones anteriores a 3.2.15.25" } ], "id": "CVE-2020-14441", "lastModified": "2024-11-21T05:03:17.100", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-18T17:15:13.233", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061946/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0071" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061946/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0071" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.6 (Critical) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbw30_firmware | * | |
netgear | rbw30 | - | |
netgear | rbs40v_firmware | * | |
netgear | rbs40v | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbk854_firmware | * | |
netgear | rbk854 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbk754_firmware | * | |
netgear | rbk754 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8EF8E22-9DC7-4A42-99E0-A6822F647DF7", "versionEndExcluding": "2.6.2.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1CA086E1-DB23-4130-B746-D56F5A188C3B", "versionEndExcluding": "2.6.2.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "64DF0B69-B591-47B6-88C1-82544AA3DE9B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "106863FF-9BE9-4C18-9A86-C458FF9EBDD6", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "matchCriteriaId": "01D12702-8B86-419C-8636-1259FD2D5844", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E1723D5F-FFDB-4E4D-80B7-4B28598D5895", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D041B9F-37E4-48A9-9841-85EFFF7FA1D1", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk754_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E6E6FDC1-BB17-454A-9B3A-5FB1F705C56B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk754:-:*:*:*:*:*:*:*", "matchCriteriaId": "F8BF464E-63DB-4AC4-9B5D-E3ECDC000305", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects RBW30 before 2.6.2.2, RBS40V before 2.6.2.4, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una omisi\u00f3n de autenticaci\u00f3n. Esto afecta a RBW30 versiones anteriores a 2.6.2.2, RBS40V versiones anteriores a 2.6.2.4, RBK852 versiones anteriores a 3.2.17.12, RBK853 versiones anteriores a 3.2.17.12, RBK854 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3. 2.17.12, RBK752 versiones anteriores a 3.2.17.12, RBK753 versiones anteriores a 3.2.17.12, RBK753S versiones anteriores a 3.2.17.12, RBK754 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12 y RBS750 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-29067", "lastModified": "2024-11-21T06:00:38.160", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-23T07:15:13.233", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063017/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0492" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063017/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0492" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk842_firmware | * | |
netgear | rbk842 | - | |
netgear | rbr840_firmware | * | |
netgear | rbr840 | - | |
netgear | rbs840_firmware | * | |
netgear | rbs840 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436BED04-0FD2-499B-9D42-F9E0AAA6CB97", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F35DDDEC-A64B-400E-ABF8-E13F432BD261", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "754ACE12-E256-4B21-ABD5-CB5F3DA4BDC7", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D19A1E4D-30F2-4263-B4BE-273EED14702E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44ED0285-F862-44B9-B0EE-C2FDC42706A2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A553C5A2-EB80-4314-A623-8F489A4E74E2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK842 versiones anteriores a 3.2.15.25, RBR840 versiones anteriores a 3.2.15.25, RBS840 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBK853 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25 y RBS850 versiones anteriores a 3.2.15.25" } ], "id": "CVE-2020-14439", "lastModified": "2024-11-21T05:03:16.763", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-18T17:15:13.047", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061942/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0064" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061942/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0064" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.6 (Critical) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbk854_firmware | * | |
netgear | rbk854 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbk754_firmware | * | |
netgear | rbk754 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "64DF0B69-B591-47B6-88C1-82544AA3DE9B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "106863FF-9BE9-4C18-9A86-C458FF9EBDD6", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "matchCriteriaId": "01D12702-8B86-419C-8636-1259FD2D5844", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E1723D5F-FFDB-4E4D-80B7-4B28598D5895", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D041B9F-37E4-48A9-9841-85EFFF7FA1D1", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk754_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E6E6FDC1-BB17-454A-9B3A-5FB1F705C56B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk754:-:*:*:*:*:*:*:*", "matchCriteriaId": "F8BF464E-63DB-4AC4-9B5D-E3ECDC000305", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a RBK852 versiones anteriores a 3.2.17.12, RBK853 versiones anteriores a 3.2.17.12, RBK854 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3.2.17.12, RBK752 versiones anteriores a 3. 2.17.12, RBK753 versiones anteriores a 3.2.17.12, RBK753S versiones anteriores a 3.2.17.12, RBK754 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12 y RBS750 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-29078", "lastModified": "2024-11-21T06:00:40.030", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-23T07:15:14.077", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063009/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0511" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063009/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0511" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.6 (Critical) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbk854_firmware | * | |
netgear | rbk854 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "64DF0B69-B591-47B6-88C1-82544AA3DE9B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "106863FF-9BE9-4C18-9A86-C458FF9EBDD6", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "matchCriteriaId": "01D12702-8B86-419C-8636-1259FD2D5844", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a RBK852 versiones anteriores a 3.2.17.12, RBK853 versiones anteriores a 3.2.17.12, RBK854 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-29079", "lastModified": "2024-11-21T06:00:40.187", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-23T07:15:14.157", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063020/Security-Advisory-for-Pre-Authentication-Command-Injection-Some-WiFi-Routers-PSV-2020-0470" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063020/Security-Advisory-for-Pre-Authentication-Command-Injection-Some-WiFi-Routers-PSV-2020-0470" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk842_firmware | * | |
netgear | rbk842 | - | |
netgear | rbr840_firmware | * | |
netgear | rbr840 | - | |
netgear | rbs840_firmware | * | |
netgear | rbs840 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436BED04-0FD2-499B-9D42-F9E0AAA6CB97", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F35DDDEC-A64B-400E-ABF8-E13F432BD261", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "754ACE12-E256-4B21-ABD5-CB5F3DA4BDC7", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D19A1E4D-30F2-4263-B4BE-273EED14702E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44ED0285-F862-44B9-B0EE-C2FDC42706A2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A553C5A2-EB80-4314-A623-8F489A4E74E2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK842 versiones anteriores a 3.2.15.25, RBR840 versiones anteriores a 3.2.15.25, RBS840 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBK853 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25 y RBS850 versiones anteriores a 3.2.15.25" } ], "id": "CVE-2020-14437", "lastModified": "2024-11-21T05:03:16.423", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-18T17:15:12.860", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061940/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0054" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061940/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0054" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk842_firmware | * | |
netgear | rbk842 | - | |
netgear | rbr840_firmware | * | |
netgear | rbr840 | - | |
netgear | rbs840_firmware | * | |
netgear | rbs840 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436BED04-0FD2-499B-9D42-F9E0AAA6CB97", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F35DDDEC-A64B-400E-ABF8-E13F432BD261", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "754ACE12-E256-4B21-ABD5-CB5F3DA4BDC7", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D19A1E4D-30F2-4263-B4BE-273EED14702E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44ED0285-F862-44B9-B0EE-C2FDC42706A2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A553C5A2-EB80-4314-A623-8F489A4E74E2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una divulgaci\u00f3n de credenciales administrativas. Esto afecta a RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK842 versiones anteriores a 3.2.15.25, RBR840 versiones anteriores a 3.2.15.25, RBS840 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBK853 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25 y RBS850 versiones anteriores a 3.2.15.25" } ], "id": "CVE-2020-14431", "lastModified": "2024-11-21T05:03:15.320", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-18T17:15:12.250", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061944/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0068" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061944/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0068" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk842_firmware | * | |
netgear | rbk842 | - | |
netgear | rbr840_firmware | * | |
netgear | rbr840 | - | |
netgear | rbs840_firmware | * | |
netgear | rbs840 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436BED04-0FD2-499B-9D42-F9E0AAA6CB97", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F35DDDEC-A64B-400E-ABF8-E13F432BD261", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "754ACE12-E256-4B21-ABD5-CB5F3DA4BDC7", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D19A1E4D-30F2-4263-B4BE-273EED14702E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44ED0285-F862-44B9-B0EE-C2FDC42706A2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A553C5A2-EB80-4314-A623-8F489A4E74E2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by CSRF. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una vulnerabilidad de tipo CSRF. Esto afecta a RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK842 versiones anteriores a 3.2.15.25, RBR840 versiones anteriores a 3.2.15.25, RBS840 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBK853 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25 y RBS850 versiones anteriores a 3.2.15.25" } ], "id": "CVE-2020-14432", "lastModified": "2024-11-21T05:03:15.507", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-18T17:15:12.327", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061937/Security-Advisory-for-Cross-Site-Request-Forgery-on-Some-WiFi-Systems-PSV-2020-0049" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061937/Security-Advisory-for-Cross-Site-Request-Forgery-on-Some-WiFi-Systems-PSV-2020-0049" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-352" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
netgear | mk62_firmware | * | |
netgear | mk62 | - | |
netgear | mk63_firmware | * | |
netgear | mk63 | - | |
netgear | mr60_firmware | * | |
netgear | mr60 | - | |
netgear | ms60_firmware | * | |
netgear | ms60 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbk842_firmware | * | |
netgear | rbk842 | - | |
netgear | rbr840_firmware | * | |
netgear | rbr840 | - | |
netgear | rbs840_firmware | * | |
netgear | rbs840 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mk62_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C17F8372-6149-455C-B48F-4BE45DC92EC7", "versionEndExcluding": "1.0.4.92", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mk62:-:*:*:*:*:*:*:*", "matchCriteriaId": "69A79475-37BE-47BD-A629-DCEF22500B0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mk63_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "08087535-0C20-4FB8-9F73-CD4817343459", "versionEndExcluding": "1.0.4.92", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mk63:-:*:*:*:*:*:*:*", "matchCriteriaId": "3DFA7D26-4286-40B2-94CB-0D2A6E6FCF1C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9584E85F-AD4C-46A2-A96A-0FE52E0B4FE9", "versionEndExcluding": "1.0.4.92", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "matchCriteriaId": "65BB3ECD-2F0B-4625-A1DB-F6CEFC46E277", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "63495F09-8D4B-4BAC-96C0-3A15D9019C14", "versionEndExcluding": "1.0.4.92", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "matchCriteriaId": "F003F064-591C-4D7C-9EC4-D0E553BC6683", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436BED04-0FD2-499B-9D42-F9E0AAA6CB97", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F35DDDEC-A64B-400E-ABF8-E13F432BD261", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "754ACE12-E256-4B21-ABD5-CB5F3DA4BDC7", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D19A1E4D-30F2-4263-B4BE-273EED14702E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44ED0285-F862-44B9-B0EE-C2FDC42706A2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A553C5A2-EB80-4314-A623-8F489A4E74E2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects MK62 before 1.0.4.92, MK63 before 1.0.4.92, MR60 before 1.0.4.92, MS60 before 1.0.4.92, RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBS750 before 3.2.15.25, RBR750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una divulgaci\u00f3n de credenciales administrativas. Esto afecta a MK62 versiones anteriores a 1.0.4.92, MK63 versiones anteriores a 1.0.4.92, MR60 versiones anteriores a 1.0.4.92, MS60 versiones anteriores a 1.0.4.92, RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBK842 versiones anteriores a 3.2.15.25, RBR840 versiones anteriores a 3.2.15.25, RBS840 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBK853 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25 y RBS850 versiones anteriores a 3.2.15.25" } ], "id": "CVE-2020-14429", "lastModified": "2024-11-21T05:03:14.980", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-18T17:15:12.077", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061938/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0050" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061938/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0050" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.1 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbr854_firmware | * | |
netgear | rbr854 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | cbr40_firmware | * | |
netgear | cbr40 | - | |
netgear | r7000_firmware | * | |
netgear | r7000 | - | |
netgear | r6900p_firmware | * | |
netgear | r6900p | - | |
netgear | r7900_firmware | * | |
netgear | r7900 | - | |
netgear | r7960p_firmware | * | |
netgear | r7960p | - | |
netgear | r8000_firmware | * | |
netgear | r8000 | - | |
netgear | r7900p_firmware | * | |
netgear | r7900p | - | |
netgear | r8000p_firmware | * | |
netgear | r8000p | - | |
netgear | rax75_firmware | * | |
netgear | rax75 | - | |
netgear | rax80_firmware | * | |
netgear | rax80 | - | |
netgear | r7000p_firmware | * | |
netgear | r7000p | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "971A9859-C378-4DEC-9432-364930E662B7", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "003185A9-52A8-42BB-A898-CE9F020AC301", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr854_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "236C92E0-52FF-4639-819E-3EF0615639A9", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr854:-:*:*:*:*:*:*:*", "matchCriteriaId": "FEB30F51-49A4-448E-971F-BC70B389554C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0B05A46-1FD0-4F51-857C-DA4F838C1A87", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D842A92-6063-4CF5-B73B-2FD9FCE4225A", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2B05686E-7206-4E3B-BDBD-05C8EA6CABB5", "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D9F1DAD0-F8B8-48D5-B571-C55636B274C3", "versionEndExcluding": "1.0.11.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44801589-B49E-4B00-84DD-EFE47526C70C", "versionEndExcluding": "1.3.2.126", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "96390A31-03B8-477B-8710-F797CB44E741", "versionEndExcluding": "1.0.4.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5B717BA8-81B7-470C-BF20-A4318D063D77", "versionEndExcluding": "1.4.1.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "matchCriteriaId": "091CEDB5-0069-4253-86D8-B9FE17CB9F24", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9F5A371E-41CA-4C5A-8DDC-3BD197F49096", "versionEndExcluding": "1.0.4.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "65F881E3-22B3-40D9-A896-51B13FD09EAA", "versionEndExcluding": "1.4.1.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "101031E9-479E-4F86-B83A-19376F8C8A45", "versionEndExcluding": "1.4.1.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ADDF0077-E02C-4DDA-A84E-DF3A0237FC66", "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81DF924F-FDA4-4588-B8A3-6F18ABBD4976", "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "182AB5A2-5D07-4A5E-A863-4EE216D6F423", "versionEndExcluding": "1.3.2.126", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by password reset by an unauthenticated attacker. This affects RBK852 before 3.2.10.11, RBK853 before 3.2.10.11, RBR854 before 3.2.10.11, RBR850 before 3.2.10.11, RBS850 before 3.2.10.11, CBR40 before 2.5.0.10, R7000 before 1.0.11.116, R6900P before 1.3.2.126, R7900 before 1.0.4.38, R7960P before 1.4.1.66, R8000 before 1.0.4.66, R7900P before 1.4.1.66, R8000P before 1.4.1.66, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, and R7000P before 1.3.2.126." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un restablecimiento de contrase\u00f1a por parte de un atacante no autenticado. Esto afecta al RBK852 versiones anteriores a 3.2.10.11, al RBK853 versiones anteriores a 3.2.10.11, al RBR854 versiones anteriores a 3.2.10.11, al RBR850 versiones anteriores a 3.2.10.11, al RBS850 versiones anteriores a 3.2.10.11, al CBR40 versiones anteriores a 2.5.0.10, al R7000 versiones anteriores a 1.0.11.116, al R6900P versiones anteriores a 1. 3.2.126, R7900 versiones anteriores a 1.0.4.38, R7960P versiones anteriores a 1.4.1.66, R8000 versiones anteriores a 1.0.4.66, R7900P versiones anteriores a 1.4.1.66, R8000P versiones anteriores a 1.4.1.66, RAX75 versiones anteriores a 1.0.3.102, RAX80 versiones anteriores a 1.0.3.102 y R7000P versiones anteriores a 1.3.2.126" } ], "id": "CVE-2021-29080", "lastModified": "2024-11-21T06:00:40.337", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 4.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.2, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.2, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-23T07:15:14.217", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063007/Security-Advisory-for-Pre-authentication-Password-Reset-on-Some-Routers-and-WiFi-Systems-PSV-2019-0150" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063007/Security-Advisory-for-Pre-authentication-Password-Reset-on-Some-Routers-and-WiFi-Systems-PSV-2019-0150" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-640" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.4 (High) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbk854_firmware | * | |
netgear | rbk854 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "64DF0B69-B591-47B6-88C1-82544AA3DE9B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "106863FF-9BE9-4C18-9A86-C458FF9EBDD6", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "matchCriteriaId": "01D12702-8B86-419C-8636-1259FD2D5844", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autentificado. Esto afecta a RBK852 versiones anteriores a 3.2.17.12, RBK853 versiones anteriores a 3.2.17.12, RBK854 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-29072", "lastModified": "2024-11-21T06:00:39.080", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-23T07:15:13.640", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063018/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0493" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063018/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0493" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4E99E8C5-D88D-409C-8233-944E254D587F", "versionEndExcluding": "1.0.4.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:v3:*:*:*:*:*:*:*", "matchCriteriaId": "5A09A9E8-8C77-4EDB-9483-B3C540EF083A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1B80222E-C65C-4AA5-9399-E2017D844117", "versionEndExcluding": "1.0.4.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:v2:*:*:*:*:*:*:*", "matchCriteriaId": "52AE9AD2-BC8D-477D-A3D3-891AE52FA5F3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D208F2CA-DB20-4C82-8FFF-B99EBFE29713", "versionEndExcluding": "1.0.11.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:*:*:*:*:*:*:*:*", "matchCriteriaId": "E5A29C8A-71C1-477F-9D17-CD2E74784BB8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "61DE3850-1661-43D1-9E52-31E2E01979EE", "versionEndExcluding": "1.3.2.124", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:*:*:*:*:*:*:*:*", "matchCriteriaId": "3524A509-D0CF-40EB-93FE-9538169CEF53", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5C6F506A-464D-4BDE-8F9B-D537D3C7E137", "versionEndExcluding": "1.3.2.124", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:*:*:*:*:*:*:*:*", "matchCriteriaId": "8DC381A4-BDC7-4F40-AD68-F9EEE5370AC1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D9800CB2-C14A-406B-B1FF-B1B62862EBDB", "versionEndExcluding": "1.0.4.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:*:*:*:*:*:*:*:*", "matchCriteriaId": "0F35362B-CF27-4C04-AD15-8579F1F6B949", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4171EB00-3664-43D5-9B62-A3538C358142", "versionEndExcluding": "1.0.5.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7850:*:*:*:*:*:*:*:*", "matchCriteriaId": "7780F243-8E08-4E1F-A819-24386B05F817", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F030129E-95C6-4C31-92A6-DABCDC1B534B", "versionEndExcluding": "1.0.4.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:*:*:*:*:*:*:*:*", "matchCriteriaId": "41BA56D3-4429-43DA-9988-A83CC92D323D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rs400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "921A8CFC-D86E-4674-998E-31F4F956B5DC", "versionEndExcluding": "1.5.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rs400:*:*:*:*:*:*:*:*", "matchCriteriaId": "BE56058F-FE7A-43D3-A362-2043B74FAE81", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "478CE991-5E30-438D-94B0-0E15A29E27BD", "versionEndExcluding": "1.0.1.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:*:*:*:*:*:*:*:*", "matchCriteriaId": "09DF14C8-CE32-47AB-B087-D8D6C84C8F98", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "19D625E4-17F4-44EF-9A51-DA0BAD4835F2", "versionEndExcluding": "1.0.2.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:*:*:*:*:*:*:*:*", "matchCriteriaId": "B0D05E55-6C70-419A-9A5D-D89AA8F19499", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B1D59AC0-2859-46C0-B050-3BB8E3E9CB06", "versionEndExcluding": "1.0.2.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:*:*:*:*:*:*:*:*", "matchCriteriaId": "E5B64473-5409-419B-967A-E4D7922D7010", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mk60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "99DA73AE-E82E-4886-9237-291B6B32BE9E", "versionEndExcluding": "1.0.5.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mk60:*:*:*:*:*:*:*:*", "matchCriteriaId": "F2581D68-BF67-43E9-9465-A510DC80C236", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3E18CCBB-46CD-423D-AA66-36F223EFD6E6", "versionEndExcluding": "1.0.5.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mr60:*:*:*:*:*:*:*:*", "matchCriteriaId": "D651DEF9-CC2F-4ADB-9FEE-5C43A8366A75", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "07A1D7A9-29E9-4B1D-90DB-24E0967C9BC7", "versionEndExcluding": "1.0.5.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ms60:*:*:*:*:*:*:*:*", "matchCriteriaId": "7467498D-EEFE-4B57-8031-B9F99751D556", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2B05686E-7206-4E3B-BDBD-05C8EA6CABB5", "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:*:*:*:*:*:*:*:*", "matchCriteriaId": "ACAD2041-9A20-444A-BB81-8764610D6F00", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3B377E02-0228-4A2F-90F3-A82E7E964B37", "versionEndExcluding": "1.4.1.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:*:*:*:*:*:*:*:*", "matchCriteriaId": "2982807D-D17B-49B8-B0D7-80662EDFC306", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA8D0327-0A72-44EC-9CC2-6CAF6A0C08B2", "versionEndExcluding": "1.4.1.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7960p:*:*:*:*:*:*:*:*", "matchCriteriaId": "5C64BD39-F245-47DB-981D-36613AD40BFF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44537647-E0B2-477D-98A5-7EA850BF3321", "versionEndExcluding": "1.4.1.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:*:*:*:*:*:*:*:*", "matchCriteriaId": "67C27B00-2FD3-4AE9-90B7-AEFA2631C9E4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC5225D5-96AD-43EE-BAA3-37B7FEF97E86", "versionEndExcluding": "1.0.1.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax15:*:*:*:*:*:*:*:*", "matchCriteriaId": "3DED03C1-00A1-49B3-BD19-DCCC489E7FE2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33505A97-35DB-4EFD-9D47-EA03057C8FFD", "versionEndExcluding": "1.0.1.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax20:*:*:*:*:*:*:*:*", "matchCriteriaId": "B881D3AF-6D5B-4AC9-BB36-E673D88BDC54", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ADDF0077-E02C-4DDA-A84E-DF3A0237FC66", "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:*:*:*:*:*:*:*:*", "matchCriteriaId": "DCF91BA6-DF2A-4121-9246-83C6DAA89C11", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81DF924F-FDA4-4588-B8A3-6F18ABBD4976", "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:*:*:*:*:*:*:*:*", "matchCriteriaId": "E4EAEF0F-DCED-4ECC-B8DF-4E91AA030D8E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "49D5D1E8-637A-4970-8753-6A3FCA8FAC64", "versionEndExcluding": "1.0.2.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax200:*:*:*:*:*:*:*:*", "matchCriteriaId": "497D21B1-4F55-408F-8D05-18B2B9F55291", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5A3B894E-E712-477A-9960-30AFAB2C35CF", "versionEndExcluding": "1.0.2.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax45:*:*:*:*:*:*:*:*", "matchCriteriaId": "80FD45DF-A29E-46C7-99DC-09EE74F5A276", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A71AE85C-74C4-42C1-BF54-89B6EC38C707", "versionEndExcluding": "1.0.2.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax50:*:*:*:*:*:*:*:*", "matchCriteriaId": "12DA6A42-4064-4884-9D8C-7273CA8F0498", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B59B0C17-2714-48E8-8911-E72488CE32E3", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7500:*:*:*:*:*:*:*:*", "matchCriteriaId": "111905EF-0E9E-4321-837F-D7E7C146E9FF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C7EE6BC6-DEDA-4005-9E29-D66D0BC7E5C2", "versionEndExcluding": "1.0.1.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:eax80:*:*:*:*:*:*:*:*", "matchCriteriaId": "06EC4DE7-7424-4D7C-9979-88C58CBB0978", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "62EFA314-85C0-48CC-938E-E2BF42B16746", "versionEndExcluding": "1.0.0.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:eax20:*:*:*:*:*:*:*:*", "matchCriteriaId": "24022452-B0A3-4101-875A-46D0B5E60D48", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:*:*:*:*:*:*:*:*", "matchCriteriaId": "31427F8E-7D14-4DE1-AF03-7487073040B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3E391711-0D34-4CBB-9022-BF809C435616", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:*:*:*:*:*:*:*:*", "matchCriteriaId": "57204B6D-6D87-4616-91ED-446894C24A3A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C348EA7B-1226-4745-9961-A5B253BE8235", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:*:*:*:*:*:*:*:*", "matchCriteriaId": "DFFAC263-BF84-404C-9A4F-BF9D1D4134E5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk754_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "85D95CCB-7E4A-4CA5-A503-FB79DBC08DDE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk754:*:*:*:*:*:*:*:*", "matchCriteriaId": "2731D467-A9C2-4801-9D41-BBECF0F4C585", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:*:*:*:*:*:*:*:*", "matchCriteriaId": "C6CB2B42-ADFE-42A7-8A9D-B5C2ED6F2E7F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB5309A5-3F84-46F4-BB50-754E9C52FA88", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:*:*:*:*:*:*:*:*", "matchCriteriaId": "4B06308A-9862-4B1E-A100-B9A8B47311B5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "02781FF1-A884-44D3-8364-FF8371D47FCA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:*:*:*:*:*:*:*:*", "matchCriteriaId": "530F895F-0061-441F-A2BD-CC51A8C13BE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAA417FF-DB33-477B-9D73-003CE56C5D78", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk854:*:*:*:*:*:*:*:*", "matchCriteriaId": "B9217A7B-0410-4E57-BD91-8E20237FB52B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:*:*:*:*:*:*:*:*", "matchCriteriaId": "A77C093D-AF25-4757-880C-698A7902D507", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:*:*:*:*:*:*:*:*", "matchCriteriaId": "7A92FEE8-77A2-49DE-BCF7-9416F64E5F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F5C6DF5F-FEFB-4A30-87CC-379E726AE181", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:*:*:*:*:*:*:*:*", "matchCriteriaId": "1AC8A705-F376-4B1F-B5AD-024CE43EB997", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "451C5603-927A-4EB9-BF9D-150FE16A48F8", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:*:*:*:*:*:*:*:*", "matchCriteriaId": "057CD043-7ACD-4284-9CC0-171F437B1501", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4B22B149-BD16-42A0-BB1D-DEF483F6B5E1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D633C05-5C85-490D-8692-BBA04C36F450", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7F898DC9-9250-47DF-844C-F7308365135B", "versionEndExcluding": "1.0.0.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6120:*:*:*:*:*:*:*:*", "matchCriteriaId": "C1B44D10-8A75-4643-8937-9157C7C1014D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0754CB8B-A9D4-4444-8426-E1DDBBD2A9D1", "versionEndExcluding": "1.0.0.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6220:*:*:*:*:*:*:*:*", "matchCriteriaId": "D00B9746-B4B1-4473-8417-BF1B10831B50", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6230_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9D35F61B-5E8F-483B-9F31-A312AB8C717F", "versionEndExcluding": "1.0.0.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6230:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8C14B49-D069-41E3-94C3-A49E06022D60", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6260_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "23D4F7E6-C042-434E-87B8-55DB18B08B0A", "versionEndExcluding": "1.1.0.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6260:*:*:*:*:*:*:*:*", "matchCriteriaId": "0E2353F3-A93F-4477-9E2E-4E23EAA5F51C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3408536D-FC77-48C5-AD15-C5A170D7417C", "versionEndExcluding": "1.1.0.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6850:*:*:*:*:*:*:*:*", "matchCriteriaId": "D4F77BFF-3640-4906-ABCF-E3C6945050E3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6350_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9F105F6F-ECD3-411D-924E-94BCF036C1EA", "versionEndExcluding": "1.1.0.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6350:*:*:*:*:*:*:*:*", "matchCriteriaId": "5B54BEAD-CF85-48AB-87EE-F09FAAF1F3D6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6330_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6524B85E-23AC-4983-8331-96E12899B773", "versionEndExcluding": "1.1.0.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6330:*:*:*:*:*:*:*:*", "matchCriteriaId": "D552EC52-5DB8-45BF-BD1B-0554FCEBCD24", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ACEAC1F2-EEAE-4880-B6C0-FFAAA29685F1", "versionEndExcluding": "1.0.1.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:*:*:*:*:*:*:*:*", "matchCriteriaId": "0C82317F-0843-4B4F-9FE0-8A44BA651D26", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A0E3BFCB-BFF8-4722-BE48-5FA93CACD3AD", "versionEndExcluding": "2.6.1.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk50:*:*:*:*:*:*:*:*", "matchCriteriaId": "4660355E-74B6-40E5-86E0-3BA55589C557", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "39D6318D-F5A2-4469-B508-075F2825F0FA", "versionEndExcluding": "2.6.1.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr50:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D9688E5-D944-437C-81AC-03CA64087DC3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1F44708A-C946-4E0F-9D6C-A91AFB4C9EF3", "versionEndExcluding": "2.6.1.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs50:*:*:*:*:*:*:*:*", "matchCriteriaId": "00C4E1D7-94CB-4A0B-9E74-89880CBFF11C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AAC56D3D-B697-4C9D-ADBB-A45845A3B5D4", "versionEndExcluding": "2.6.1.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk40:*:*:*:*:*:*:*:*", "matchCriteriaId": "AADEEDB6-C8F5-41D3-93C8-AB94605554C9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1E21623E-9977-486F-93B1-858FC407E9D1", "versionEndExcluding": "2.6.1.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr40:*:*:*:*:*:*:*:*", "matchCriteriaId": "5428D4B4-DEEC-4A14-BF24-EB480A614FA8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A32769CF-7D0A-4A3F-AF20-6202CA0C6870", "versionEndExcluding": "2.6.1.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40:*:*:*:*:*:*:*:*", "matchCriteriaId": "772CF322-9944-4243-BFBB-8F133AE5A373", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk23_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "675E9C59-D39B-47B0-ABEC-32D548650AB7", "versionEndExcluding": "2.6.1.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk23:*:*:*:*:*:*:*:*", "matchCriteriaId": "752FA3EA-C87D-4402-ACFF-11E1DE15501B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C1612C65-9BA0-4CAF-93B3-D528287B0790", "versionEndExcluding": "2.6.1.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr20:*:*:*:*:*:*:*:*", "matchCriteriaId": "BE1E01AE-DE82-4F20-BCFB-E5A48CCE28AA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "04F03BE5-1440-4BC4-B902-97E702ED0ADF", "versionEndExcluding": "2.6.1.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs20:*:*:*:*:*:*:*:*", "matchCriteriaId": "B12E8664-5D49-4377-A8C4-175F15E94083", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk12_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9EC30751-F447-45A7-8C57-B73042869EA5", "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk12:*:*:*:*:*:*:*:*", "matchCriteriaId": "D26AB2BC-061D-4142-9E37-A22368398876", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk13_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2E7758BF-0AE4-46DB-A014-734F68AEEAA0", "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk13:*:*:*:*:*:*:*:*", "matchCriteriaId": "52BB59CE-7024-4F7C-B49B-C2444FAA923E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk14_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B7CD38DB-B4A3-460E-8F89-E85A0E0F5BD3", "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk14:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0CD88D0-E4F4-4695-A2BE-44758F6CA4C4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk15_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3E25990D-C38A-44E7-A301-AB9E80A9D5CA", "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk15:*:*:*:*:*:*:*:*", "matchCriteriaId": "87232E4A-7821-4A7A-8D31-67C91DCCA5B2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr10_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8246B8D3-8455-43B1-B0FA-F677B8FF84F5", "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr10:*:*:*:*:*:*:*:*", "matchCriteriaId": "69E984D9-C35E-4925-A3C3-695BCEF56C75", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs10_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "28DA498C-B466-422E-BAD2-A1F9A15B157F", "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs10:*:*:*:*:*:*:*:*", "matchCriteriaId": "B0242C44-637E-4984-B830-9148E265E74B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B8956A99-1071-42A7-8984-D7134E755CBF", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6800:*:*:*:*:*:*:*:*", "matchCriteriaId": "6F3127F5-9624-4002-B8F8-D76A01676ADA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A660042D-27F6-4110-AB03-BCAFAC194557", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E8EB69B-6619-47B6-A073-D0B840D4EB0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AFA2C5B9-92C2-4E70-B166-87AD9973F80E", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:v2:*:*:*:*:*:*:*", "matchCriteriaId": "9F9706E6-CA53-43E4-91B0-D52655C86860", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "02279B20-D951-46CE-B339-452BC585A4F3", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7200:*:*:*:*:*:*:*:*", "matchCriteriaId": "E330A8C5-1D91-4743-A35C-430CB5EAA0A2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7350_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B452611A-43C5-401B-95BD-189020B5C65C", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7350:*:*:*:*:*:*:*:*", "matchCriteriaId": "F27FB281-6C22-45E6-A3A1-DE90C3F2B608", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "237C68C0-C2A9-4F71-9E08-547F2A317CBC", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7400:*:*:*:*:*:*:*:*", "matchCriteriaId": "CE8F6B4F-5995-40A4-89B4-325BACA086A2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7450_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "63697E3A-AAA3-42E7-8116-93C6548D3AB7", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7450:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB5E5161-10A9-41A9-9FC4-9A5F6B4536AA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ac2100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4C1280B1-A2DF-4CAB-AB19-6B463206AA3D", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ac2100:*:*:*:*:*:*:*:*", "matchCriteriaId": "DDFA0025-8657-4A20-A282-D1034D8BBEF3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ac2400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76C658A4-BF82-40CE-A5E1-C9F3DA1A9B0B", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ac2400:*:*:*:*:*:*:*:*", "matchCriteriaId": "710011A1-F633-4B5D-9C09-04E518C71DE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ac2600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4A3A6655-B468-46FB-84D7-2294D4243C91", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ac2600:*:*:*:*:*:*:*:*", "matchCriteriaId": "474A7CEB-7133-40FA-8FC5-BC85D712DABF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C393DBF4-8281-4611-B591-CDB9DF0AA958", "versionEndExcluding": "1.0.2.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:*:*:*:*:*:*:*:*", "matchCriteriaId": "01CF301B-9DF5-4960-BD62-06E56EDF1031", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "57314D03-64B1-4973-9D36-5D22A71DBCBB", "versionEndExcluding": "1.0.5.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:*:*:*:*:*:*:*:*", "matchCriteriaId": "0CD4841B-0F5C-4B7B-9764-F37605BF7AD9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DCE56F2-5A45-4B31-99EF-1D8455C71E5C", "versionEndExcluding": "1.0.5.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:*:*:*:*:*:*:*:*", "matchCriteriaId": "E4AAEB70-4F97-4044-B897-86020787DE01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B697A877-214C-4701-AA9B-FE9C23FDBCEB", "versionEndExcluding": "1.0.1.136", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax120:*:*:*:*:*:*:*:*", "matchCriteriaId": "B302272A-8BCE-47B7-B7DB-026B22A39367", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr450_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "051E8D2A-0EB0-43A7-9AAA-8519B8CC7FE0", "versionEndExcluding": "2.3.2.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr450:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA83AEEB-FBEB-40A9-9F61-814596C00922", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0BCFB551-95C6-4EEF-83F0-4246F67E6668", "versionEndExcluding": "2.3.2.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr500:*:*:*:*:*:*:*:*", "matchCriteriaId": "7F284951-6DAA-4AA4-A189-44CDB44878A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "89AB672D-DD24-483E-B69D-7E46AF199483", "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr700:*:*:*:*:*:*:*:*", "matchCriteriaId": "1AF919EF-8893-4E1A-A854-3FB932682504", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D71EDB94-370B-46C3-A14E-3F3FB130DD49", "versionEndExcluding": "1.0.3.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr300:*:*:*:*:*:*:*:*", "matchCriteriaId": "AED2DE10-EC70-4A50-9C17-2C02569BD149", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects R6700v3 before 1.0.4.98, R6400v2 before 1.0.4.98, R7000 before 1.0.11.106, R6900P before 1.3.2.124, R7000P before 1.3.2.124, R7900 before 1.0.4.26, R7850 before 1.0.5.60, R8000 before 1.0.4.58, RS400 before 1.5.0.48, R6400 before 1.0.1.62, R6700 before 1.0.2.16, R6900 before 1.0.2.16, MK60 before 1.0.5.102, MR60 before 1.0.5.102, MS60 before 1.0.5.102, CBR40 before 2.5.0.10, R8000P before 1.4.1.62, R7960P before 1.4.1.62, R7900P before 1.4.1.62, RAX15 before 1.0.1.64, RAX20 before 1.0.1.64, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RAX200 before 1.0.2.102, RAX45 before 1.0.2.64, RAX50 before 1.0.2.64, EX7500 before 1.0.0.68, EAX80 before 1.0.1.62, EAX20 before 1.0.0.36, RBK752 before 3.2.16.6, RBK753 before 3.2.16.6, RBK753S before 3.2.16.6, RBK754 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBK853 before 3.2.16.6, RBK854 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RBR840 before 3.2.16.6, RBS840 before 3.2.16.6, R6120 before 1.0.0.70, R6220 before 1.1.0.100, R6230 before 1.1.0.100, R6260 before 1.1.0.76, R6850 before 1.1.0.76, R6350 before 1.1.0.76, R6330 before 1.1.0.76, D7800 before 1.0.1.58, RBK50 before 2.6.1.40, RBR50 before 2.6.1.40, RBS50 before 2.6.1.40, RBK40 before 2.6.1.36, RBR40 before 2.6.1.36, RBS40 before 2.6.1.38, RBK23 before 2.6.1.36, RBR20 before 2.6.1.38, RBS20 before 2.6.1.38, RBK12 before 2.6.1.44, RBK13 before 2.6.1.44, RBK14 before 2.6.1.44, RBK15 before 2.6.1.44, RBR10 before 2.6.1.44, RBS10 before 2.6.1.44, R6800 before 1.2.0.72, R6900v2 before 1.2.0.72, R6700v2 before 1.2.0.72, R7200 before 1.2.0.72, R7350 before 1.2.0.72, R7400 before 1.2.0.72, R7450 before 1.2.0.72, AC2100 before 1.2.0.72, AC2400 before 1.2.0.72, AC2600 before 1.2.0.72, R7800 before 1.0.2.74, R8900 before 1.0.5.24, R9000 before 1.0.5.24, RAX120 before 1.0.1.136, XR450 before 2.3.2.66, XR500 before 2.3.2.66, XR700 before 1.0.1.34, and XR300 before 1.0.3.50." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer por parte de un usuario autenticado. Esto afecta al R6700v3 versiones anteriores a 1.0.4.98, al R6400v2 versiones anteriores a 1.0.4.98, al R7000 versiones anteriores a 1.0.11.106, al R6900P versiones anteriores a 1.3.2.124, al R7000P versiones anteriores a 1.3.2.124, al R7900 versiones anteriores a 1.0.4.26, al R7850 versiones anteriores a 1.0.5.60, al R8000 versiones anteriores a 1.0.4.58, al RS400 versiones anteriores a 1.5.0.48, al R6400 versiones anteriores a 1.0.1. 62, R6700 versiones anteriores a 1.0.2.16, R6900 versiones anteriores a 1.0.2.16, MK60 versiones anteriores a 1.0.5.102, MR60 versiones anteriores a 1.0.5.102, MS60 versiones anteriores a 1.0.5.102, CBR40 versiones anteriores a 2.5.0.10, R8000P versiones anteriores a 1.4.1.62, R7960P versiones anteriores a 1.4.1.62, R7900P versiones anteriores a 1.4.1.62, RAX15 versiones anteriores a 1.0.1.64, RAX20 versiones anteriores a 1. 0.1.64, RAX75 versiones anteriores a 1.0.3.102, RAX80 versiones anteriores a 1.0.3.102, RAX200 versiones anteriores a 1.0.2.102, RAX45 versiones anteriores a 1.0.2.64, RAX50 versiones anteriores a 1.0.2.64, EX7500 versiones anteriores a 1.0.0.68, EAX80 versiones anteriores a 1.0.1.62, EAX20 versiones anteriores a 1.0.0.36, RBK752 versiones anteriores a 3.2.16.6, RBK753 versiones anteriores a 3.2.16. 6, RBK753S versiones anteriores a 3.2.16.6, RBK754 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16. 6, RBK853 versiones anteriores a 3.2.16.6, RBK854 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6, RBS850 versiones anteriores a 3.2.16.6, RBR840 versiones anteriores a 3.2.16. 6, RBS840 versiones anteriores a 3.2.16.6, R6120 versiones anteriores a 1.0.0.70, R6220 versiones anteriores a 1.1.0.100, R6230 versiones anteriores a 1.1.0.100, R6260 versiones anteriores a 1.1.0.76, R6850 versiones anteriores a 1.1.0.76, R6350 versiones anteriores a 1.1.0.76, R6330 versiones anteriores a 1.1.0.76, D7800 versiones anteriores a 1.0.1.58, RBK50 versiones anteriores a 2.6.1.40, RBR50 versiones anteriores a 2. 6.1.40, RBS50 versiones anteriores a 2.6.1.40, RBK40 versiones anteriores a 2.6.1.36, RBR40 versiones anteriores a 2.6.1.36, RBS40 versiones anteriores a 2.6.1.38, RBK23 versiones anteriores a 2.6.1.36, RBR20 versiones anteriores a 2.6.1.38, RBS20 versiones anteriores a 2.6.1.38, RBK12 versiones anteriores a 2.6.1.44, RBK13 versiones anteriores a 2.6.1.44, RBK14 versiones anteriores a 2.6.1. 44, RBK15 versiones anteriores a 2.6.1.44, RBR10 versiones anteriores a 2.6.1.44, RBS10 versiones anteriores a 2.6.1.44, R6800 versiones anteriores a 1.2.0.72, R6900v2 versiones anteriores a 1.2.0. 72, R6700v2 versiones anteriores a 1.2.0.72, R7200 versiones anteriores a 1.2.0.72, R7350 versiones anteriores a 1.2.0.72, R7400 versiones anteriores a 1.2.0.72, R7450 versiones anteriores a 1.2.0.72, AC2100 versiones anteriores a 1. 2.0.72, AC2400 versiones anteriores a 1.2.0.72, AC2600 versiones anteriores a 1.2.0.72, R7800 versiones anteriores a 1.0.2.74, R8900 versiones anteriores a 1.0.5.24, R9000 versiones anteriores a 1.0.5.24, RAX120 versiones anteriores a 1.0.1.136, XR450 versiones anteriores a 2.3.2.66, XR500 versiones anteriores a 2.3.2.66, XR700 versiones anteriores a 1.0.1.34 y XR300 versiones anteriores a 1.0.3.50" } ], "id": "CVE-2021-29068", "lastModified": "2024-11-21T06:00:38.353", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.9, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.1, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-23T07:15:13.297", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063021/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0155" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063021/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0155" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.4 (High) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbw30_firmware | * | |
netgear | rbw30 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbk854_firmware | * | |
netgear | rbk854 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbk754_firmware | * | |
netgear | rbk754 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8EF8E22-9DC7-4A42-99E0-A6822F647DF7", "versionEndExcluding": "2.6.2.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "64DF0B69-B591-47B6-88C1-82544AA3DE9B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "106863FF-9BE9-4C18-9A86-C458FF9EBDD6", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "matchCriteriaId": "01D12702-8B86-419C-8636-1259FD2D5844", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E1723D5F-FFDB-4E4D-80B7-4B28598D5895", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D041B9F-37E4-48A9-9841-85EFFF7FA1D1", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk754_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E6E6FDC1-BB17-454A-9B3A-5FB1F705C56B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk754:-:*:*:*:*:*:*:*", "matchCriteriaId": "F8BF464E-63DB-4AC4-9B5D-E3ECDC000305", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects RBW30 before 2.6.2.2, RBK852 before 3.2.17.12, RBK852 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a RBW30 versiones anteriores a 2.6.2.2, RBK852 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3.2.17. 12, RBK752 versiones anteriores a 3.2.17.12, RBK753 versiones anteriores a 3.2.17.12, RBK753S versiones anteriores a 3.2.17.12, RBK754 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12 y RBS750 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-29075", "lastModified": "2024-11-21T06:00:39.567", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-23T07:15:13.857", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063010/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-WiFi-Systems-PSV-2020-0466" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063010/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-WiFi-Systems-PSV-2020-0466" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk842_firmware | * | |
netgear | rbk842 | - | |
netgear | rbr840_firmware | * | |
netgear | rbr840 | - | |
netgear | rbs840_firmware | * | |
netgear | rbs840 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436BED04-0FD2-499B-9D42-F9E0AAA6CB97", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F35DDDEC-A64B-400E-ABF8-E13F432BD261", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "754ACE12-E256-4B21-ABD5-CB5F3DA4BDC7", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D19A1E4D-30F2-4263-B4BE-273EED14702E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44ED0285-F862-44B9-B0EE-C2FDC42706A2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A553C5A2-EB80-4314-A623-8F489A4E74E2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una divulgaci\u00f3n de credenciales administrativas. Esto afecta a RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK842 versiones anteriores a 3.2.15.25, RBR840 versiones anteriores a 3.2.15.25, RBS840 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBK853 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25 y RBS850 versiones anteriores a 3.2.15.25" } ], "id": "CVE-2020-14428", "lastModified": "2024-11-21T05:03:14.810", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-18T17:15:12.000", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061936/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0044" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061936/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0044" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.4 (High) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbw30_firmware | * | |
netgear | rbw30 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbk854_firmware | * | |
netgear | rbk854 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbk754_firmware | * | |
netgear | rbk754 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8EF8E22-9DC7-4A42-99E0-A6822F647DF7", "versionEndExcluding": "2.6.2.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "64DF0B69-B591-47B6-88C1-82544AA3DE9B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "106863FF-9BE9-4C18-9A86-C458FF9EBDD6", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "matchCriteriaId": "01D12702-8B86-419C-8636-1259FD2D5844", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E1723D5F-FFDB-4E4D-80B7-4B28598D5895", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D041B9F-37E4-48A9-9841-85EFFF7FA1D1", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk754_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E6E6FDC1-BB17-454A-9B3A-5FB1F705C56B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk754:-:*:*:*:*:*:*:*", "matchCriteriaId": "F8BF464E-63DB-4AC4-9B5D-E3ECDC000305", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects RBW30 before 2.6.2.2, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a RBW30 versiones anteriores a 2.6.2.2, RBK852 versiones anteriores a 3.2.17.12, RBK853 versiones anteriores a 3.2.17.12, RBK854 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3.2.17. 12, RBK752 versiones anteriores a 3.2.17.12, RBK753 versiones anteriores a 3.2.17.12, RBK753S versiones anteriores a 3.2.17.12, RBK754 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12 y RBS750 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-29074", "lastModified": "2024-11-21T06:00:39.400", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-23T07:15:13.797", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063011/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-WiFi-Routers-PSV-2020-0467" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063011/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-WiFi-Routers-PSV-2020-0467" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.4 (High) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbw30_firmware | * | |
netgear | rbw30 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbk854_firmware | * | |
netgear | rbk854 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbk754_firmware | * | |
netgear | rbk754 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8EF8E22-9DC7-4A42-99E0-A6822F647DF7", "versionEndExcluding": "2.6.2.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "64DF0B69-B591-47B6-88C1-82544AA3DE9B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "106863FF-9BE9-4C18-9A86-C458FF9EBDD6", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "matchCriteriaId": "01D12702-8B86-419C-8636-1259FD2D5844", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E1723D5F-FFDB-4E4D-80B7-4B28598D5895", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D041B9F-37E4-48A9-9841-85EFFF7FA1D1", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk754_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E6E6FDC1-BB17-454A-9B3A-5FB1F705C56B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk754:-:*:*:*:*:*:*:*", "matchCriteriaId": "F8BF464E-63DB-4AC4-9B5D-E3ECDC000305", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects RBW30 before 2.6.2.2, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un atacante no autenticado. Esto afecta a RBW30 versiones anteriores a 2.6.2.2, RBK852 versiones anteriores a 3.2.17.12, RBK853 versiones anteriores a 3.2.17.12, RBK854 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3.2.17. 12, RBK752 versiones anteriores a 3.2.17.12, RBK753 versiones anteriores a 3.2.17.12, RBK753S versiones anteriores a 3.2.17.12, RBK754 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12 y RBS750 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-29081", "lastModified": "2024-11-21T06:00:40.503", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-23T07:15:14.310", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063012/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-WiFi-Systems-PSV-2020-0465" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063012/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-WiFi-Systems-PSV-2020-0465" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
var-202103-1271
Vulnerability from variot
Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects R6700v3 before 1.0.4.98, R6400v2 before 1.0.4.98, R7000 before 1.0.11.106, R6900P before 1.3.2.124, R7000P before 1.3.2.124, R7900 before 1.0.4.26, R7850 before 1.0.5.60, R8000 before 1.0.4.58, RS400 before 1.5.0.48, R6400 before 1.0.1.62, R6700 before 1.0.2.16, R6900 before 1.0.2.16, MK60 before 1.0.5.102, MR60 before 1.0.5.102, MS60 before 1.0.5.102, CBR40 before 2.5.0.10, R8000P before 1.4.1.62, R7960P before 1.4.1.62, R7900P before 1.4.1.62, RAX15 before 1.0.1.64, RAX20 before 1.0.1.64, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RAX200 before 1.0.2.102, RAX45 before 1.0.2.64, RAX50 before 1.0.2.64, EX7500 before 1.0.0.68, EAX80 before 1.0.1.62, EAX20 before 1.0.0.36, RBK752 before 3.2.16.6, RBK753 before 3.2.16.6, RBK753S before 3.2.16.6, RBK754 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBK853 before 3.2.16.6, RBK854 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RBR840 before 3.2.16.6, RBS840 before 3.2.16.6, R6120 before 1.0.0.70, R6220 before 1.1.0.100, R6230 before 1.1.0.100, R6260 before 1.1.0.76, R6850 before 1.1.0.76, R6350 before 1.1.0.76, R6330 before 1.1.0.76, D7800 before 1.0.1.58, RBK50 before 2.6.1.40, RBR50 before 2.6.1.40, RBS50 before 2.6.1.40, RBK40 before 2.6.1.36, RBR40 before 2.6.1.36, RBS40 before 2.6.1.38, RBK23 before 2.6.1.36, RBR20 before 2.6.1.38, RBS20 before 2.6.1.38, RBK12 before 2.6.1.44, RBK13 before 2.6.1.44, RBK14 before 2.6.1.44, RBK15 before 2.6.1.44, RBR10 before 2.6.1.44, RBS10 before 2.6.1.44, R6800 before 1.2.0.72, R6900v2 before 1.2.0.72, R6700v2 before 1.2.0.72, R7200 before 1.2.0.72, R7350 before 1.2.0.72, R7400 before 1.2.0.72, R7450 before 1.2.0.72, AC2100 before 1.2.0.72, AC2400 before 1.2.0.72, AC2600 before 1.2.0.72, R7800 before 1.0.2.74, R8900 before 1.0.5.24, R9000 before 1.0.5.24, RAX120 before 1.0.1.136, XR450 before 2.3.2.66, XR500 before 2.3.2.66, XR700 before 1.0.1.34, and XR300 before 1.0.3.50. plural NETGEAR A classic buffer overflow vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects R6700v3 prior to 1.0.4.98, R6400v2 prior to 1.0.4.98, R7000 prior to 1.0.11.106, R6900P prior to 1.3.2.124, R7000P prior to 1.3.2.124, R7900 prior to 1.0.4.26, R7850 prior to 1.0.5.60, R8000 prior to 1.0.4.58, RS400 prior to 1.5.0.48, R6400 prior to 1.0.1.62, R6700 prior to 1.0.2.16, R6900 prior to 1.0.2.16, MK60 prior to 1.0.5.102, MR60 prior to 1.0.5.102, MS60 prior to 1.0.5.102, CBR40 prior to 2.5.0.10, R8000P prior to 1.4.1.62, R7960P prior to 1.4.1.62, R7900P prior to 1.4.1.62, RAX15 prior to 1.0.1.64, RAX20 prior to 1.0.1.64, RAX75 prior to 1.0.3.102, RAX80 prior to 1.0.3.102, RAX200 prior to 1.0.2.102, RAX45 prior to 1.0.2.64, RAX50 prior to 1.0.2.64, EX7500 prior to 1.0.0.68, EAX80 prior to 1.0.1.62, EAX20 prior to 1.0.0.36, RBK752 prior to 3.2.16.6, RBK753 prior to 3.2.16.6, RBK753S prior to 3.2.16.6, RBK754 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBK853 prior to 3.2.16.6, RBK854 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, RBS850 prior to 3.2.16.6, RBR840 prior to 3.2.16.6, RBS840 prior to 3.2.16.6, R6120 prior to 1.0.0.70, R6220 prior to 1.1.0.100, R6230 prior to 1.1.0.100, R6260 prior to 1.1.0.76, R6850 prior to 1.1.0.76, R6350 prior to 1.1.0.76, R6330 prior to 1.1.0.76, D7800 prior to 1.0.1.58, RBK50 prior to 2.6.1.40, RBR50 prior to 2.6.1.40, RBS50 prior to 2.6.1.40, RBK40 prior to 2.6.1.36, RBR40 prior to 2.6.1.36, RBS40 prior to 2.6.1.38, RBK23 prior to 2.6.1.36, RBR20 prior to 2.6.1.38, RBS20 prior to 2.6.1.38, RBK12 prior to 2.6.1.44, RBK13 prior to 2.6.1.44, RBK14 prior to 2.6.1.44, RBK15 prior to 2.6.1.44, RBR10 prior to 2.6.1.44, RBS10 prior to 2.6.1.44, R6800 prior to 1.2.0.72, R6900v2 prior to 1.2.0.72, R6700v2 prior to 1.2.0.72, R7200 prior to 1.2.0.72, R7350 prior to 1.2.0.72, R7400 prior to 1.2.0.72, R7450 prior to 1.2.0.72, AC2100 prior to 1.2.0.72, AC2400 prior to 1.2.0.72, AC2600 prior to 1.2.0.72, R7800 prior to 1.0.2.74, R8900 prior to 1.0.5.24, R9000 prior to 1.0.5.24, RAX120 prior to 1.0.1.136, XR450 prior to 2.3.2.66, XR500 prior to 2.3.2.66, XR700 prior to 1.0.1.34, and XR300 prior to 1.0.3.50
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1271", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "r6900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "ms60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.102" }, { "model": "rax200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.102" }, { "model": "r7400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "rbr50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.40" }, { "model": "r6900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.16" }, { "model": "r7350", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.40" }, { "model": "rbk12", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.44" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.36" }, { "model": "rbs10", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.44" }, { "model": "rax120", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.136" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.102" }, { "model": "r9000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.24" }, { "model": "rbk854", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "eax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.62" }, { "model": "r7800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.74" }, { "model": "r7900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.26" }, { "model": "ac2100", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "rbk753", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "xr300", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.50" }, { "model": "d7800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.58" }, { "model": "rax50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.64" }, { "model": "rbr20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.38" }, { "model": "r6260", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.0.76" }, { "model": "r8900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.24" }, { "model": "rbk14", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.44" }, { "model": "r6120", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.70" }, { "model": "xr700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.34" }, { "model": "ex7500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.68" }, { "model": "rbk23", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.36" }, { "model": "xr500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.2.66" }, { "model": "rbr840", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "r7960p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.62" }, { "model": "rbk15", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.44" }, { "model": "ac2600", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "rbs50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.40" }, { "model": "rax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.64" }, { "model": "rbs20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.38" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.10" }, { "model": "ac2400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "r6220", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.70" }, { "model": "r6330", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.0.76" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "r8000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.62" }, { "model": "rbk853", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "r6900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.2.124" }, { "model": "r6800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "xr450", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.2.66" }, { "model": "r6400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.98" }, { "model": "rs400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.5.0.48" }, { "model": "r6350", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.0.76" }, { "model": "r6700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.98" }, { "model": "r7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.11.106" }, { "model": "rbk13", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.44" }, { "model": "r7850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.60" }, { "model": "r6400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.62" }, { "model": "mr60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.102" }, { "model": "eax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.36" }, { "model": "rbk842", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "r7200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "r6700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "r8000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.58" }, { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.102" }, { "model": "rbk754", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "r6700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.16" }, { "model": "rax45", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.64" }, { "model": "rbk753s", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "r6230", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.70" }, { "model": "rbs40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.38" }, { "model": "rax15", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.64" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "r6850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.0.76" }, { "model": "rbk40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.36" }, { "model": "r7450", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "rbs840", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "r7900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.62" }, { "model": "r7000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.2.124" }, { "model": "mk60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.102" }, { "model": "rbr10", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.44" }, { "model": "r6900p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7000p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7000", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r6400", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7900", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r8000", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r6700", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-005326" }, { "db": "NVD", "id": "CVE-2021-29068" } ] }, "cve": "CVE-2021-29068", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "id": "CVE-2021-29068", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2021-29068", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 9.9, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.1, "id": "CVE-2021-29068", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-29068", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-29068", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-29068", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2021-29068", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-202103-1360", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-29068", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29068" }, { "db": "JVNDB", "id": "JVNDB-2021-005326" }, { "db": "CNNVD", "id": "CNNVD-202103-1360" }, { "db": "NVD", "id": "CVE-2021-29068" }, { "db": "NVD", "id": "CVE-2021-29068" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects R6700v3 before 1.0.4.98, R6400v2 before 1.0.4.98, R7000 before 1.0.11.106, R6900P before 1.3.2.124, R7000P before 1.3.2.124, R7900 before 1.0.4.26, R7850 before 1.0.5.60, R8000 before 1.0.4.58, RS400 before 1.5.0.48, R6400 before 1.0.1.62, R6700 before 1.0.2.16, R6900 before 1.0.2.16, MK60 before 1.0.5.102, MR60 before 1.0.5.102, MS60 before 1.0.5.102, CBR40 before 2.5.0.10, R8000P before 1.4.1.62, R7960P before 1.4.1.62, R7900P before 1.4.1.62, RAX15 before 1.0.1.64, RAX20 before 1.0.1.64, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RAX200 before 1.0.2.102, RAX45 before 1.0.2.64, RAX50 before 1.0.2.64, EX7500 before 1.0.0.68, EAX80 before 1.0.1.62, EAX20 before 1.0.0.36, RBK752 before 3.2.16.6, RBK753 before 3.2.16.6, RBK753S before 3.2.16.6, RBK754 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBK853 before 3.2.16.6, RBK854 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RBR840 before 3.2.16.6, RBS840 before 3.2.16.6, R6120 before 1.0.0.70, R6220 before 1.1.0.100, R6230 before 1.1.0.100, R6260 before 1.1.0.76, R6850 before 1.1.0.76, R6350 before 1.1.0.76, R6330 before 1.1.0.76, D7800 before 1.0.1.58, RBK50 before 2.6.1.40, RBR50 before 2.6.1.40, RBS50 before 2.6.1.40, RBK40 before 2.6.1.36, RBR40 before 2.6.1.36, RBS40 before 2.6.1.38, RBK23 before 2.6.1.36, RBR20 before 2.6.1.38, RBS20 before 2.6.1.38, RBK12 before 2.6.1.44, RBK13 before 2.6.1.44, RBK14 before 2.6.1.44, RBK15 before 2.6.1.44, RBR10 before 2.6.1.44, RBS10 before 2.6.1.44, R6800 before 1.2.0.72, R6900v2 before 1.2.0.72, R6700v2 before 1.2.0.72, R7200 before 1.2.0.72, R7350 before 1.2.0.72, R7400 before 1.2.0.72, R7450 before 1.2.0.72, AC2100 before 1.2.0.72, AC2400 before 1.2.0.72, AC2600 before 1.2.0.72, R7800 before 1.0.2.74, R8900 before 1.0.5.24, R9000 before 1.0.5.24, RAX120 before 1.0.1.136, XR450 before 2.3.2.66, XR500 before 2.3.2.66, XR700 before 1.0.1.34, and XR300 before 1.0.3.50. plural NETGEAR A classic buffer overflow vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects R6700v3 prior to 1.0.4.98, R6400v2 prior to 1.0.4.98, R7000 prior to 1.0.11.106, R6900P prior to 1.3.2.124, R7000P prior to 1.3.2.124, R7900 prior to 1.0.4.26, R7850 prior to 1.0.5.60, R8000 prior to 1.0.4.58, RS400 prior to 1.5.0.48, R6400 prior to 1.0.1.62, R6700 prior to 1.0.2.16, R6900 prior to 1.0.2.16, MK60 prior to 1.0.5.102, MR60 prior to 1.0.5.102, MS60 prior to 1.0.5.102, CBR40 prior to 2.5.0.10, R8000P prior to 1.4.1.62, R7960P prior to 1.4.1.62, R7900P prior to 1.4.1.62, RAX15 prior to 1.0.1.64, RAX20 prior to 1.0.1.64, RAX75 prior to 1.0.3.102, RAX80 prior to 1.0.3.102, RAX200 prior to 1.0.2.102, RAX45 prior to 1.0.2.64, RAX50 prior to 1.0.2.64, EX7500 prior to 1.0.0.68, EAX80 prior to 1.0.1.62, EAX20 prior to 1.0.0.36, RBK752 prior to 3.2.16.6, RBK753 prior to 3.2.16.6, RBK753S prior to 3.2.16.6, RBK754 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBK853 prior to 3.2.16.6, RBK854 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, RBS850 prior to 3.2.16.6, RBR840 prior to 3.2.16.6, RBS840 prior to 3.2.16.6, R6120 prior to 1.0.0.70, R6220 prior to 1.1.0.100, R6230 prior to 1.1.0.100, R6260 prior to 1.1.0.76, R6850 prior to 1.1.0.76, R6350 prior to 1.1.0.76, R6330 prior to 1.1.0.76, D7800 prior to 1.0.1.58, RBK50 prior to 2.6.1.40, RBR50 prior to 2.6.1.40, RBS50 prior to 2.6.1.40, RBK40 prior to 2.6.1.36, RBR40 prior to 2.6.1.36, RBS40 prior to 2.6.1.38, RBK23 prior to 2.6.1.36, RBR20 prior to 2.6.1.38, RBS20 prior to 2.6.1.38, RBK12 prior to 2.6.1.44, RBK13 prior to 2.6.1.44, RBK14 prior to 2.6.1.44, RBK15 prior to 2.6.1.44, RBR10 prior to 2.6.1.44, RBS10 prior to 2.6.1.44, R6800 prior to 1.2.0.72, R6900v2 prior to 1.2.0.72, R6700v2 prior to 1.2.0.72, R7200 prior to 1.2.0.72, R7350 prior to 1.2.0.72, R7400 prior to 1.2.0.72, R7450 prior to 1.2.0.72, AC2100 prior to 1.2.0.72, AC2400 prior to 1.2.0.72, AC2600 prior to 1.2.0.72, R7800 prior to 1.0.2.74, R8900 prior to 1.0.5.24, R9000 prior to 1.0.5.24, RAX120 prior to 1.0.1.136, XR450 prior to 2.3.2.66, XR500 prior to 2.3.2.66, XR700 prior to 1.0.1.34, and XR300 prior to 1.0.3.50", "sources": [ { "db": "NVD", "id": "CVE-2021-29068" }, { "db": "JVNDB", "id": "JVNDB-2021-005326" }, { "db": "VULMON", "id": "CVE-2021-29068" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-29068", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-005326", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202103-1360", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-29068", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29068" }, { "db": "JVNDB", "id": "JVNDB-2021-005326" }, { "db": "CNNVD", "id": "CNNVD-202103-1360" }, { "db": "NVD", "id": "CVE-2021-29068" } ] }, "id": "VAR-202103-1271", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.3117663121621622 }, "last_update_date": "2024-11-23T23:04:04.570000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Buffer\u00a0Overflow\u00a0on\u00a0Some\u00a0Routers,\u00a0Extenders,\u00a0and\u00a0WiFi\u00a0Systems\u00a0,\u00a0PSV-2020-0155", "trust": 0.8, "url": "https://kb.netgear.com/000063021/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0155" }, { "title": "Netgear NETGEAR Buffer error vulnerability fix", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=145681" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-005326" }, { "db": "CNNVD", "id": "CNNVD-202103-1360" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-120", "trust": 1.0 }, { "problemtype": "Classic buffer overflow (CWE-120) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-005326" }, { "db": "NVD", "id": "CVE-2021-29068" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000063021/security-advisory-for-post-authentication-buffer-overflow-on-some-routers-extenders-and-wifi-systems-psv-2020-0155" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29068" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/120.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29068" }, { "db": "JVNDB", "id": "JVNDB-2021-005326" }, { "db": "CNNVD", "id": "CNNVD-202103-1360" }, { "db": "NVD", "id": "CVE-2021-29068" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-29068" }, { "db": "JVNDB", "id": "JVNDB-2021-005326" }, { "db": "CNNVD", "id": "CNNVD-202103-1360" }, { "db": "NVD", "id": "CVE-2021-29068" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-23T00:00:00", "db": "VULMON", "id": "CVE-2021-29068" }, { "date": "2021-12-13T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-005326" }, { "date": "2021-03-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1360" }, { "date": "2021-03-23T07:15:13.297000", "db": "NVD", "id": "CVE-2021-29068" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-27T00:00:00", "db": "VULMON", "id": "CVE-2021-29068" }, { "date": "2021-12-13T01:53:00", "db": "JVNDB", "id": "JVNDB-2021-005326" }, { "date": "2021-03-30T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1360" }, { "date": "2024-11-21T06:00:38.353000", "db": "NVD", "id": "CVE-2021-29068" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1360" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Classic buffer overflow vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-005326" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1360" } ], "trust": 0.6 } }
var-202103-1278
Vulnerability from variot
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects RBW30 before 2.6.2.2, RBK852 before 3.2.17.12, RBK852 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12. plural NETGEAR The device contains an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBW30 prior to 2.6.2.2, RBK852 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, RBK753 prior to 3.2.17.12, RBK753S prior to 3.2.17.12, RBK754 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, and RBS750 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1278", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk753", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk754", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbw30", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.2.2" }, { "model": "rbk853", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk753s", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk854", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk753s", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk853", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbw30", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk854", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk753", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk754", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004581" }, { "db": "NVD", "id": "CVE-2021-29075" } ] }, "cve": "CVE-2021-29075", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "id": "CVE-2021-29075", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.9, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "id": "CVE-2021-29075", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 8.4, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-004581", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-29075", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-29075", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2021-29075", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-202103-1352", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-29075", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29075" }, { "db": "JVNDB", "id": "JVNDB-2021-004581" }, { "db": "CNNVD", "id": "CNNVD-202103-1352" }, { "db": "NVD", "id": "CVE-2021-29075" }, { "db": "NVD", "id": "CVE-2021-29075" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects RBW30 before 2.6.2.2, RBK852 before 3.2.17.12, RBK852 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12. plural NETGEAR The device contains an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBW30 prior to 2.6.2.2, RBK852 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, RBK753 prior to 3.2.17.12, RBK753S prior to 3.2.17.12, RBK754 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, and RBS750 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-29075" }, { "db": "JVNDB", "id": "JVNDB-2021-004581" }, { "db": "VULMON", "id": "CVE-2021-29075" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-29075", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2021-004581", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202103-1352", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-29075", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29075" }, { "db": "JVNDB", "id": "JVNDB-2021-004581" }, { "db": "CNNVD", "id": "CNNVD-202103-1352" }, { "db": "NVD", "id": "CVE-2021-29075" } ] }, "id": "VAR-202103-1278", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.303985029 }, "last_update_date": "2024-11-23T22:33:06.417000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Stack\u00a0Overflow\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0466", "trust": 0.8, "url": "https://kb.netgear.com/000063010/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-WiFi-Systems-PSV-2020-0466" }, { "title": "NETGEAR Repair measures for buffer errors and vulnerabilities in many products", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=144970" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004581" }, { "db": "CNNVD", "id": "CNNVD-202103-1352" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004581" }, { "db": "NVD", "id": "CVE-2021-29075" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000063010/security-advisory-for-post-authentication-stack-overflow-on-some-wifi-systems-psv-2020-0466" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29075" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/787.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29075" }, { "db": "JVNDB", "id": "JVNDB-2021-004581" }, { "db": "CNNVD", "id": "CNNVD-202103-1352" }, { "db": "NVD", "id": "CVE-2021-29075" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-29075" }, { "db": "JVNDB", "id": "JVNDB-2021-004581" }, { "db": "CNNVD", "id": "CNNVD-202103-1352" }, { "db": "NVD", "id": "CVE-2021-29075" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-23T00:00:00", "db": "VULMON", "id": "CVE-2021-29075" }, { "date": "2021-11-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-004581" }, { "date": "2021-03-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1352" }, { "date": "2021-03-23T07:15:13.857000", "db": "NVD", "id": "CVE-2021-29075" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-24T00:00:00", "db": "VULMON", "id": "CVE-2021-29075" }, { "date": "2021-11-25T03:10:00", "db": "JVNDB", "id": "JVNDB-2021-004581" }, { "date": "2021-08-16T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1352" }, { "date": "2024-11-21T06:00:39.567000", "db": "NVD", "id": "CVE-2021-29075" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1352" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Out-of-bounds write vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004581" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1352" } ], "trust": 0.6 } }
var-202006-0586
Vulnerability from variot
Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR Devices contain vulnerabilities in insufficient protection of credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR.
There are security vulnerabilities in many NETGEAR products. Attackers can use this vulnerability to obtain management credentials
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0586", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk752", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-62723" }, { "db": "JVNDB", "id": "JVNDB-2020-006749" }, { "db": "NVD", "id": "CVE-2020-14428" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:netgear:rbk752_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk753_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk753s_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk842_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk852_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk853_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr750_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr840_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr850_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs750_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs840_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs850_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006749" } ] }, "cve": "CVE-2020-14428", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CVE-2020-14428", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "LOW", "trust": 1.0, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "None", "baseScore": 3.3, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2020-006749", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CNVD-2021-62723", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "LOW", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2020-14428", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2020-14428", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-006749", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2020-14428", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-14428", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "JVNDB-2020-006749", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-62723", "trust": 0.6, "value": "LOW" }, { "author": "CNNVD", "id": "CNNVD-202006-1241", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-62723" }, { "db": "JVNDB", "id": "JVNDB-2020-006749" }, { "db": "CNNVD", "id": "CNNVD-202006-1241" }, { "db": "NVD", "id": "CVE-2020-14428" }, { "db": "NVD", "id": "CVE-2020-14428" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR Devices contain vulnerabilities in insufficient protection of credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. \n\r\n\r\nThere are security vulnerabilities in many NETGEAR products. Attackers can use this vulnerability to obtain management credentials", "sources": [ { "db": "NVD", "id": "CVE-2020-14428" }, { "db": "JVNDB", "id": "JVNDB-2020-006749" }, { "db": "CNVD", "id": "CNVD-2021-62723" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-14428", "trust": 3.0 }, { "db": "JVNDB", "id": "JVNDB-2020-006749", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-62723", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202006-1241", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-62723" }, { "db": "JVNDB", "id": "JVNDB-2020-006749" }, { "db": "CNNVD", "id": "CNNVD-202006-1241" }, { "db": "NVD", "id": "CVE-2020-14428" } ] }, "id": "VAR-202006-0586", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-62723" } ], "trust": 1.0097272085714286 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-62723" } ] }, "last_update_date": "2024-11-23T21:35:44.493000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Admin Credential Disclosure on Some WiFi Systems, PSV-2020-0044", "trust": 0.8, "url": "https://kb.netgear.com/000061936/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0044" }, { "title": "Patch for Information Disclosure Vulnerabilities in Multiple NETGEAR Products (CNVD-2021-62723)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/275116" }, { "title": "Multiple NETGEAR Product security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=121990" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-62723" }, { "db": "JVNDB", "id": "JVNDB-2020-006749" }, { "db": "CNNVD", "id": "CNNVD-202006-1241" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "CWE-522", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006749" }, { "db": "NVD", "id": "CVE-2020-14428" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14428" }, { "trust": 1.6, "url": "https://kb.netgear.com/000061936/security-advisory-for-admin-credential-disclosure-on-some-wifi-systems-psv-2020-0044" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14428" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-62723" }, { "db": "JVNDB", "id": "JVNDB-2020-006749" }, { "db": "CNNVD", "id": "CNNVD-202006-1241" }, { "db": "NVD", "id": "CVE-2020-14428" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-62723" }, { "db": "JVNDB", "id": "JVNDB-2020-006749" }, { "db": "CNNVD", "id": "CNNVD-202006-1241" }, { "db": "NVD", "id": "CVE-2020-14428" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-62723" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006749" }, { "date": "2020-06-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1241" }, { "date": "2020-06-18T17:15:12", "db": "NVD", "id": "CVE-2020-14428" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-08-17T00:00:00", "db": "CNVD", "id": "CNVD-2021-62723" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006749" }, { "date": "2020-06-22T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1241" }, { "date": "2024-11-21T05:03:14.810000", "db": "NVD", "id": "CVE-2020-14428" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1241" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR Inadequate protection of credentials on devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006749" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1241" } ], "trust": 0.6 } }
var-202006-0935
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR On the device OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. Attackers can use this vulnerability to execute arbitrary Shell commands on the system by sending a specially crafted request. This affects RBK752 prior to 3.2.15.25, RBK753 prior to 3.2.15.25, RBK753S prior to 3.2.15.25, RBR750 prior to 3.2.15.25, RBS750 prior to 3.2.15.25, RBK842 prior to 3.2.15.25, RBR840 prior to 3.2.15.25, RBS840 prior to 3.2.15.25, RBK852 prior to 3.2.15.25, RBK853 prior to 3.2.15.25, RBR850 prior to 3.2.15.25, and RBS850 prior to 3.2.15.25
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0935", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk752", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44783" }, { "db": "JVNDB", "id": "JVNDB-2020-006685" }, { "db": "NVD", "id": "CVE-2020-14438" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:netgear:rbk752_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk753_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk753s_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk842_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk852_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk853_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr750_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr840_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs750_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs840_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006685" } ] }, "cve": "CVE-2020-14438", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CVE-2020-14438", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.1, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2020-006685", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "HIGH", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 4.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 3.2, "id": "CNVD-2021-44783", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:A/AC:H/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2020-14438", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2020-14438", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-006685", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2020-14438", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-14438", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "JVNDB-2020-006685", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-44783", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202006-1254", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2020-14438", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44783" }, { "db": "VULMON", "id": "CVE-2020-14438" }, { "db": "JVNDB", "id": "JVNDB-2020-006685" }, { "db": "CNNVD", "id": "CNNVD-202006-1254" }, { "db": "NVD", "id": "CVE-2020-14438" }, { "db": "NVD", "id": "CVE-2020-14438" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR On the device OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. Attackers can use this vulnerability to execute arbitrary Shell commands on the system by sending a specially crafted request. This affects RBK752 prior to 3.2.15.25, RBK753 prior to 3.2.15.25, RBK753S prior to 3.2.15.25, RBR750 prior to 3.2.15.25, RBS750 prior to 3.2.15.25, RBK842 prior to 3.2.15.25, RBR840 prior to 3.2.15.25, RBS840 prior to 3.2.15.25, RBK852 prior to 3.2.15.25, RBK853 prior to 3.2.15.25, RBR850 prior to 3.2.15.25, and RBS850 prior to 3.2.15.25", "sources": [ { "db": "NVD", "id": "CVE-2020-14438" }, { "db": "JVNDB", "id": "JVNDB-2020-006685" }, { "db": "CNVD", "id": "CNVD-2021-44783" }, { "db": "VULMON", "id": "CVE-2020-14438" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-14438", "trust": 3.1 }, { "db": "JVNDB", "id": "JVNDB-2020-006685", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-44783", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202006-1254", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2020-14438", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44783" }, { "db": "VULMON", "id": "CVE-2020-14438" }, { "db": "JVNDB", "id": "JVNDB-2020-006685" }, { "db": "CNNVD", "id": "CNNVD-202006-1254" }, { "db": "NVD", "id": "CVE-2020-14438" } ] }, "id": "VAR-202006-0935", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-44783" } ], "trust": 1.0097272085714286 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44783" } ] }, "last_update_date": "2024-11-23T23:07:56.401000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Pre-Authentification Command Injection on Some WiFi Systems, PSV-2020-0063", "trust": 0.8, "url": "https://kb.netgear.com/000061941/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0063" }, { "title": "Patch for Operating system command injection vulnerabilities in multiple NETGEAR products (CNVD-2021-44783)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/274926" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44783" }, { "db": "JVNDB", "id": "JVNDB-2020-006685" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "CWE-78", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006685" }, { "db": "NVD", "id": "CVE-2020-14438" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14438" }, { "trust": 1.7, "url": "https://kb.netgear.com/000061941/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0063" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14438" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44783" }, { "db": "VULMON", "id": "CVE-2020-14438" }, { "db": "JVNDB", "id": "JVNDB-2020-006685" }, { "db": "CNNVD", "id": "CNNVD-202006-1254" }, { "db": "NVD", "id": "CVE-2020-14438" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-44783" }, { "db": "VULMON", "id": "CVE-2020-14438" }, { "db": "JVNDB", "id": "JVNDB-2020-006685" }, { "db": "CNNVD", "id": "CNNVD-202006-1254" }, { "db": "NVD", "id": "CVE-2020-14438" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44783" }, { "date": "2020-06-18T00:00:00", "db": "VULMON", "id": "CVE-2020-14438" }, { "date": "2020-07-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006685" }, { "date": "2020-06-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1254" }, { "date": "2020-06-18T17:15:12.953000", "db": "NVD", "id": "CVE-2020-14438" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44783" }, { "date": "2021-07-21T00:00:00", "db": "VULMON", "id": "CVE-2020-14438" }, { "date": "2020-07-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006685" }, { "date": "2020-07-02T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1254" }, { "date": "2024-11-21T05:03:16.597000", "db": "NVD", "id": "CVE-2020-14438" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1254" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR On the device OS Command injection vulnerabilities", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006685" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "operating system commend injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1254" } ], "trust": 0.6 } }
var-202103-1282
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1282", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk853", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk854", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk853", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk854", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004584" }, { "db": "NVD", "id": "CVE-2021-29079" } ] }, "cve": "CVE-2021-29079", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CVE-2021-29079", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.9, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2021-29079", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 9.6, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-004584", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-29079", "trust": 1.0, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2021-29079", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2021-29079", "trust": 0.8, "value": "Critical" }, { "author": "CNNVD", "id": "CNNVD-202103-1344", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-29079", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29079" }, { "db": "JVNDB", "id": "JVNDB-2021-004584" }, { "db": "CNNVD", "id": "CNNVD-202103-1344" }, { "db": "NVD", "id": "CVE-2021-29079" }, { "db": "NVD", "id": "CVE-2021-29079" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-29079" }, { "db": "JVNDB", "id": "JVNDB-2021-004584" }, { "db": "VULMON", "id": "CVE-2021-29079" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-29079", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2021-004584", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202103-1344", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-29079", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29079" }, { "db": "JVNDB", "id": "JVNDB-2021-004584" }, { "db": "CNNVD", "id": "CNNVD-202103-1344" }, { "db": "NVD", "id": "CVE-2021-29079" } ] }, "id": "VAR-202103-1282", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.3648863 }, "last_update_date": "2024-11-23T21:34:47.618000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Command\u00a0Injection\u00a0Some\u00a0WiFi\u00a0Routers,\u00a0PSV-2020-0470", "trust": 0.8, "url": "https://kb.netgear.com/000063020/Security-Advisory-for-Pre-Authentication-Command-Injection-Some-WiFi-Routers-PSV-2020-0470" }, { "title": "NETGEAR Repair measures for command injection vulnerabilities in multiple products", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=145160" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004584" }, { "db": "CNNVD", "id": "CNNVD-202103-1344" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004584" }, { "db": "NVD", "id": "CVE-2021-29079" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000063020/security-advisory-for-pre-authentication-command-injection-some-wifi-routers-psv-2020-0470" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29079" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29079" }, { "db": "JVNDB", "id": "JVNDB-2021-004584" }, { "db": "CNNVD", "id": "CNNVD-202103-1344" }, { "db": "NVD", "id": "CVE-2021-29079" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-29079" }, { "db": "JVNDB", "id": "JVNDB-2021-004584" }, { "db": "CNNVD", "id": "CNNVD-202103-1344" }, { "db": "NVD", "id": "CVE-2021-29079" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-23T00:00:00", "db": "VULMON", "id": "CVE-2021-29079" }, { "date": "2021-11-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-004584" }, { "date": "2021-03-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1344" }, { "date": "2021-03-23T07:15:14.157000", "db": "NVD", "id": "CVE-2021-29079" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-24T00:00:00", "db": "VULMON", "id": "CVE-2021-29079" }, { "date": "2021-11-25T03:10:00", "db": "JVNDB", "id": "JVNDB-2021-004584" }, { "date": "2021-08-16T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1344" }, { "date": "2024-11-21T06:00:40.187000", "db": "NVD", "id": "CVE-2021-29079" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1344" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004584" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1344" } ], "trust": 0.6 } }
var-202103-1279
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR The product contains a command injection vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1279", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk853", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk854", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk854", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk853", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004909" }, { "db": "NVD", "id": "CVE-2021-29076" } ] }, "cve": "CVE-2021-29076", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CVE-2021-29076", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.9, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2021-29076", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 9.6, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-004909", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-29076", "trust": 1.0, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2021-29076", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2021-29076", "trust": 0.8, "value": "Critical" }, { "author": "CNNVD", "id": "CNNVD-202103-1347", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-29076", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29076" }, { "db": "JVNDB", "id": "JVNDB-2021-004909" }, { "db": "CNNVD", "id": "CNNVD-202103-1347" }, { "db": "NVD", "id": "CVE-2021-29076" }, { "db": "NVD", "id": "CVE-2021-29076" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR The product contains a command injection vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-29076" }, { "db": "JVNDB", "id": "JVNDB-2021-004909" }, { "db": "VULMON", "id": "CVE-2021-29076" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-29076", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2021-004909", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202103-1347", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-29076", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29076" }, { "db": "JVNDB", "id": "JVNDB-2021-004909" }, { "db": "CNNVD", "id": "CNNVD-202103-1347" }, { "db": "NVD", "id": "CVE-2021-29076" } ] }, "id": "VAR-202103-1279", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.3648863 }, "last_update_date": "2024-11-23T22:20:50.335000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0485", "trust": 0.8, "url": "https://kb.netgear.com/000063015/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0485" }, { "title": "Netgear NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=145677" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004909" }, { "db": "CNNVD", "id": "CNNVD-202103-1347" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004909" }, { "db": "NVD", "id": "CVE-2021-29076" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000063015/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0485" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29076" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29076" }, { "db": "JVNDB", "id": "JVNDB-2021-004909" }, { "db": "CNNVD", "id": "CNNVD-202103-1347" }, { "db": "NVD", "id": "CVE-2021-29076" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-29076" }, { "db": "JVNDB", "id": "JVNDB-2021-004909" }, { "db": "CNNVD", "id": "CNNVD-202103-1347" }, { "db": "NVD", "id": "CVE-2021-29076" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-23T00:00:00", "db": "VULMON", "id": "CVE-2021-29076" }, { "date": "2021-12-02T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-004909" }, { "date": "2021-03-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1347" }, { "date": "2021-03-23T07:15:13.920000", "db": "NVD", "id": "CVE-2021-29076" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-26T00:00:00", "db": "VULMON", "id": "CVE-2021-29076" }, { "date": "2021-12-02T06:23:00", "db": "JVNDB", "id": "JVNDB-2021-004909" }, { "date": "2021-03-30T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1347" }, { "date": "2024-11-21T06:00:39.723000", "db": "NVD", "id": "CVE-2021-29076" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1347" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerabilities in the product", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004909" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1347" } ], "trust": 0.6 } }
var-202006-0934
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR On the device OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. Attackers can use this vulnerability to execute arbitrary Shell commands on the system by sending a specially crafted request
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0934", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk752", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44782" }, { "db": "JVNDB", "id": "JVNDB-2020-006684" }, { "db": "NVD", "id": "CVE-2020-14437" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:netgear:rbk752_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk753_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk753s_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk842_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk852_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk853_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr750_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr840_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs750_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs840_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006684" } ] }, "cve": "CVE-2020-14437", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CVE-2020-14437", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.0, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2020-006684", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CNVD-2021-44782", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2020-14437", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2020-14437", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-006684", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2020-14437", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-14437", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "JVNDB-2020-006684", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-44782", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202006-1253", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44782" }, { "db": "JVNDB", "id": "JVNDB-2020-006684" }, { "db": "CNNVD", "id": "CNNVD-202006-1253" }, { "db": "NVD", "id": "CVE-2020-14437" }, { "db": "NVD", "id": "CVE-2020-14437" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR On the device OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. Attackers can use this vulnerability to execute arbitrary Shell commands on the system by sending a specially crafted request", "sources": [ { "db": "NVD", "id": "CVE-2020-14437" }, { "db": "JVNDB", "id": "JVNDB-2020-006684" }, { "db": "CNVD", "id": "CNVD-2021-44782" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-14437", "trust": 3.0 }, { "db": "JVNDB", "id": "JVNDB-2020-006684", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-44782", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202006-1253", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44782" }, { "db": "JVNDB", "id": "JVNDB-2020-006684" }, { "db": "CNNVD", "id": "CNNVD-202006-1253" }, { "db": "NVD", "id": "CVE-2020-14437" } ] }, "id": "VAR-202006-0934", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-44782" } ], "trust": 1.0097272085714286 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44782" } ] }, "last_update_date": "2024-11-23T22:41:00.813000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Pre-Authentification Command Injection on Some WiFi Systems, PSV-2020-0054", "trust": 0.8, "url": "https://kb.netgear.com/000061940/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0054" }, { "title": "Patch for Operating system command injection vulnerabilities in multiple NETGEAR products (CNVD-2021-44782)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/275021" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44782" }, { "db": "JVNDB", "id": "JVNDB-2020-006684" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "CWE-78", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006684" }, { "db": "NVD", "id": "CVE-2020-14437" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14437" }, { "trust": 1.6, "url": "https://kb.netgear.com/000061940/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0054" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14437" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44782" }, { "db": "JVNDB", "id": "JVNDB-2020-006684" }, { "db": "CNNVD", "id": "CNNVD-202006-1253" }, { "db": "NVD", "id": "CVE-2020-14437" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-44782" }, { "db": "JVNDB", "id": "JVNDB-2020-006684" }, { "db": "CNNVD", "id": "CNNVD-202006-1253" }, { "db": "NVD", "id": "CVE-2020-14437" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44782" }, { "date": "2020-07-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006684" }, { "date": "2020-06-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1253" }, { "date": "2020-06-18T17:15:12.860000", "db": "NVD", "id": "CVE-2020-14437" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44782" }, { "date": "2020-07-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006684" }, { "date": "2020-07-02T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1253" }, { "date": "2024-11-21T05:03:16.423000", "db": "NVD", "id": "CVE-2020-14437" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1253" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR On the device OS Command injection vulnerabilities", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006684" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "operating system commend injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1253" } ], "trust": 0.6 } }
var-202006-0585
Vulnerability from variot
Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR Devices contain vulnerabilities in insufficient protection of credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR.
There are security vulnerabilities in many NETGEAR products. Attackers can use this vulnerability to obtain management credentials
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0585", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk752", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44774" }, { "db": "JVNDB", "id": "JVNDB-2020-006748" }, { "db": "NVD", "id": "CVE-2020-14427" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:netgear:rbk752_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk753_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk753s_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk842_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk852_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk853_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr750_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr840_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr850_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs750_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs840_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs850_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006748" } ] }, "cve": "CVE-2020-14427", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CVE-2020-14427", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "LOW", "trust": 1.0, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "None", "baseScore": 3.3, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2020-006748", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CNVD-2021-44774", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "LOW", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2020-14427", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2020-14427", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-006748", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2020-14427", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-14427", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "JVNDB-2020-006748", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-44774", "trust": 0.6, "value": "LOW" }, { "author": "CNNVD", "id": "CNNVD-202006-1240", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44774" }, { "db": "JVNDB", "id": "JVNDB-2020-006748" }, { "db": "CNNVD", "id": "CNNVD-202006-1240" }, { "db": "NVD", "id": "CVE-2020-14427" }, { "db": "NVD", "id": "CVE-2020-14427" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR Devices contain vulnerabilities in insufficient protection of credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. \n\r\n\r\nThere are security vulnerabilities in many NETGEAR products. Attackers can use this vulnerability to obtain management credentials", "sources": [ { "db": "NVD", "id": "CVE-2020-14427" }, { "db": "JVNDB", "id": "JVNDB-2020-006748" }, { "db": "CNVD", "id": "CNVD-2021-44774" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-14427", "trust": 3.0 }, { "db": "JVNDB", "id": "JVNDB-2020-006748", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-44774", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202006-1240", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44774" }, { "db": "JVNDB", "id": "JVNDB-2020-006748" }, { "db": "CNNVD", "id": "CNNVD-202006-1240" }, { "db": "NVD", "id": "CVE-2020-14427" } ] }, "id": "VAR-202006-0585", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-44774" } ], "trust": 1.0097272085714286 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44774" } ] }, "last_update_date": "2024-11-23T21:51:28.138000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Admin Credential Disclosure on Some WiFi Systems, PSV-2020-0042", "trust": 0.8, "url": "https://kb.netgear.com/000061935/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0042" }, { "title": "Patch for Information Disclosure Vulnerabilities in Multiple NETGEAR Products (CNVD-2021-44774)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/275076" }, { "title": "Multiple NETGEAR Product security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=121989" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44774" }, { "db": "JVNDB", "id": "JVNDB-2020-006748" }, { "db": "CNNVD", "id": "CNNVD-202006-1240" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "CWE-522", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006748" }, { "db": "NVD", "id": "CVE-2020-14427" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14427" }, { "trust": 1.6, "url": "https://kb.netgear.com/000061935/security-advisory-for-admin-credential-disclosure-on-some-wifi-systems-psv-2020-0042" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14427" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44774" }, { "db": "JVNDB", "id": "JVNDB-2020-006748" }, { "db": "CNNVD", "id": "CNNVD-202006-1240" }, { "db": "NVD", "id": "CVE-2020-14427" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-44774" }, { "db": "JVNDB", "id": "JVNDB-2020-006748" }, { "db": "CNNVD", "id": "CNNVD-202006-1240" }, { "db": "NVD", "id": "CVE-2020-14427" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44774" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006748" }, { "date": "2020-06-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1240" }, { "date": "2020-06-18T17:15:11.920000", "db": "NVD", "id": "CVE-2020-14427" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44774" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006748" }, { "date": "2020-06-22T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1240" }, { "date": "2024-11-21T05:03:14.637000", "db": "NVD", "id": "CVE-2020-14427" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1240" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR Inadequate protection of credentials on devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006748" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1240" } ], "trust": 0.6 } }
var-202103-1274
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBR752 before 3.2.17.12, RBR753 before 3.2.17.12, RBR753S before 3.2.17.12, RBR754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBR752 prior to 3.2.17.12, RBR753 prior to 3.2.17.12, RBR753S prior to 3.2.17.12, RBR754 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, and RBS750 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1274", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr754", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr753", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr753s", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk853", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk854", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk853", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr753s", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk854", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr753", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr754", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004577" }, { "db": "NVD", "id": "CVE-2021-29071" } ] }, "cve": "CVE-2021-29071", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "id": "CVE-2021-29071", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.9, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.0, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.3, "id": "CVE-2021-29071", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2021-29071", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.0, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-29071", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-29071", "trust": 1.0, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2021-29071", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2021-29071", "trust": 0.8, "value": "Critical" }, { "author": "CNNVD", "id": "CNNVD-202103-1355", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-29071", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29071" }, { "db": "JVNDB", "id": "JVNDB-2021-004577" }, { "db": "CNNVD", "id": "CNNVD-202103-1355" }, { "db": "NVD", "id": "CVE-2021-29071" }, { "db": "NVD", "id": "CVE-2021-29071" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBR752 before 3.2.17.12, RBR753 before 3.2.17.12, RBR753S before 3.2.17.12, RBR754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBR752 prior to 3.2.17.12, RBR753 prior to 3.2.17.12, RBR753S prior to 3.2.17.12, RBR754 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, and RBS750 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-29071" }, { "db": "JVNDB", "id": "JVNDB-2021-004577" }, { "db": "VULMON", "id": "CVE-2021-29071" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-29071", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2021-004577", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202103-1355", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-29071", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29071" }, { "db": "JVNDB", "id": "JVNDB-2021-004577" }, { "db": "CNNVD", "id": "CNNVD-202103-1355" }, { "db": "NVD", "id": "CVE-2021-29071" } ] }, "id": "VAR-202103-1274", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.25306323 }, "last_update_date": "2024-11-23T22:37:03.060000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0476", "trust": 0.8, "url": "https://kb.netgear.com/000063008/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0476" }, { "title": "NETGEAR Repair measures for command injection vulnerabilities in multiple products", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=144973" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004577" }, { "db": "CNNVD", "id": "CNNVD-202103-1355" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004577" }, { "db": "NVD", "id": "CVE-2021-29071" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000063008/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0476" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29071" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29071" }, { "db": "JVNDB", "id": "JVNDB-2021-004577" }, { "db": "CNNVD", "id": "CNNVD-202103-1355" }, { "db": "NVD", "id": "CVE-2021-29071" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-29071" }, { "db": "JVNDB", "id": "JVNDB-2021-004577" }, { "db": "CNNVD", "id": "CNNVD-202103-1355" }, { "db": "NVD", "id": "CVE-2021-29071" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-23T00:00:00", "db": "VULMON", "id": "CVE-2021-29071" }, { "date": "2021-11-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-004577" }, { "date": "2021-03-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1355" }, { "date": "2021-03-23T07:15:13.560000", "db": "NVD", "id": "CVE-2021-29071" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-24T00:00:00", "db": "VULMON", "id": "CVE-2021-29071" }, { "date": "2021-11-25T03:10:00", "db": "JVNDB", "id": "JVNDB-2021-004577" }, { "date": "2021-08-16T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1355" }, { "date": "2024-11-21T06:00:38.910000", "db": "NVD", "id": "CVE-2021-29071" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1355" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004577" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1355" } ], "trust": 0.6 } }
var-202006-0928
Vulnerability from variot
Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR Devices contain vulnerabilities in insufficient protection of credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR.
There are security vulnerabilities in many NETGEAR products. Attackers can use this vulnerability to obtain management credentials
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0928", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk752", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44776" }, { "db": "JVNDB", "id": "JVNDB-2020-006743" }, { "db": "NVD", "id": "CVE-2020-14431" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:netgear:rbk752_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk753_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk753s_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk842_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk852_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk853_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr750_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr840_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr850_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs750_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs840_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs850_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006743" } ] }, "cve": "CVE-2020-14431", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CVE-2020-14431", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "LOW", "trust": 1.0, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "None", "baseScore": 3.3, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2020-006743", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CNVD-2021-44776", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "LOW", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2020-14431", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2020-14431", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-006743", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2020-14431", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-14431", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "JVNDB-2020-006743", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-44776", "trust": 0.6, "value": "LOW" }, { "author": "CNNVD", "id": "CNNVD-202006-1245", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44776" }, { "db": "JVNDB", "id": "JVNDB-2020-006743" }, { "db": "CNNVD", "id": "CNNVD-202006-1245" }, { "db": "NVD", "id": "CVE-2020-14431" }, { "db": "NVD", "id": "CVE-2020-14431" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR Devices contain vulnerabilities in insufficient protection of credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. \n\r\n\r\nThere are security vulnerabilities in many NETGEAR products. Attackers can use this vulnerability to obtain management credentials", "sources": [ { "db": "NVD", "id": "CVE-2020-14431" }, { "db": "JVNDB", "id": "JVNDB-2020-006743" }, { "db": "CNVD", "id": "CNVD-2021-44776" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-14431", "trust": 3.0 }, { "db": "JVNDB", "id": "JVNDB-2020-006743", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-44776", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202006-1245", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44776" }, { "db": "JVNDB", "id": "JVNDB-2020-006743" }, { "db": "CNNVD", "id": "CNNVD-202006-1245" }, { "db": "NVD", "id": "CVE-2020-14431" } ] }, "id": "VAR-202006-0928", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-44776" } ], "trust": 1.0097272085714286 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44776" } ] }, "last_update_date": "2024-11-23T22:47:58.932000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Admin Credential Disclosure on Some WiFi Systems, PSV-2020-0068", "trust": 0.8, "url": "https://kb.netgear.com/000061944/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0068" }, { "title": "Patch for Information Disclosure Vulnerabilities in Multiple NETGEAR Products (CNVD-2021-44776)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/275106" }, { "title": "Multiple NETGEAR Product security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=121993" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44776" }, { "db": "JVNDB", "id": "JVNDB-2020-006743" }, { "db": "CNNVD", "id": "CNNVD-202006-1245" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "CWE-522", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006743" }, { "db": "NVD", "id": "CVE-2020-14431" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14431" }, { "trust": 1.6, "url": "https://kb.netgear.com/000061944/security-advisory-for-admin-credential-disclosure-on-some-wifi-systems-psv-2020-0068" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14431" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44776" }, { "db": "JVNDB", "id": "JVNDB-2020-006743" }, { "db": "CNNVD", "id": "CNNVD-202006-1245" }, { "db": "NVD", "id": "CVE-2020-14431" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-44776" }, { "db": "JVNDB", "id": "JVNDB-2020-006743" }, { "db": "CNNVD", "id": "CNNVD-202006-1245" }, { "db": "NVD", "id": "CVE-2020-14431" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44776" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006743" }, { "date": "2020-06-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1245" }, { "date": "2020-06-18T17:15:12.250000", "db": "NVD", "id": "CVE-2020-14431" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44776" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006743" }, { "date": "2020-06-22T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1245" }, { "date": "2024-11-21T05:03:15.320000", "db": "NVD", "id": "CVE-2020-14431" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1245" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR Inadequate protection of credentials on devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006743" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1245" } ], "trust": 0.6 } }
var-202006-0937
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR On the device OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. Attackers can use this vulnerability to execute arbitrary Shell commands on the system by sending a specially crafted request
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0937", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk752", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44785" }, { "db": "JVNDB", "id": "JVNDB-2020-006681" }, { "db": "NVD", "id": "CVE-2020-14440" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:netgear:rbk752_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk753_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk753s_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk842_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk852_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk853_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr750_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr840_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs750_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs840_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006681" } ] }, "cve": "CVE-2020-14440", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CVE-2020-14440", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.0, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2020-006681", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CNVD-2021-44785", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2020-14440", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2020-14440", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-006681", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2020-14440", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-14440", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "JVNDB-2020-006681", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-44785", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202006-1259", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44785" }, { "db": "JVNDB", "id": "JVNDB-2020-006681" }, { "db": "CNNVD", "id": "CNNVD-202006-1259" }, { "db": "NVD", "id": "CVE-2020-14440" }, { "db": "NVD", "id": "CVE-2020-14440" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR On the device OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. Attackers can use this vulnerability to execute arbitrary Shell commands on the system by sending a specially crafted request", "sources": [ { "db": "NVD", "id": "CVE-2020-14440" }, { "db": "JVNDB", "id": "JVNDB-2020-006681" }, { "db": "CNVD", "id": "CNVD-2021-44785" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-14440", "trust": 3.0 }, { "db": "JVNDB", "id": "JVNDB-2020-006681", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-44785", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202006-1259", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44785" }, { "db": "JVNDB", "id": "JVNDB-2020-006681" }, { "db": "CNNVD", "id": "CNNVD-202006-1259" }, { "db": "NVD", "id": "CVE-2020-14440" } ] }, "id": "VAR-202006-0937", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-44785" } ], "trust": 1.0097272085714286 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44785" } ] }, "last_update_date": "2024-11-23T22:55:07.986000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Pre-Authentification Command Injection on Some WiFi Systems, PSV-2020-0065", "trust": 0.8, "url": "https://kb.netgear.com/000061943/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0065" }, { "title": "Patch for Operating system command injection vulnerabilities in multiple NETGEAR products (CNVD-2021-44785)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/275041" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44785" }, { "db": "JVNDB", "id": "JVNDB-2020-006681" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "CWE-78", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006681" }, { "db": "NVD", "id": "CVE-2020-14440" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14440" }, { "trust": 1.6, "url": "https://kb.netgear.com/000061943/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0065" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14440" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44785" }, { "db": "JVNDB", "id": "JVNDB-2020-006681" }, { "db": "CNNVD", "id": "CNNVD-202006-1259" }, { "db": "NVD", "id": "CVE-2020-14440" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-44785" }, { "db": "JVNDB", "id": "JVNDB-2020-006681" }, { "db": "CNNVD", "id": "CNNVD-202006-1259" }, { "db": "NVD", "id": "CVE-2020-14440" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44785" }, { "date": "2020-07-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006681" }, { "date": "2020-06-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1259" }, { "date": "2020-06-18T17:15:13.140000", "db": "NVD", "id": "CVE-2020-14440" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44785" }, { "date": "2020-07-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006681" }, { "date": "2020-07-02T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1259" }, { "date": "2024-11-21T05:03:16.930000", "db": "NVD", "id": "CVE-2020-14440" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1259" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR On the device OS Command injection vulnerabilities", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006681" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "operating system commend injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1259" } ], "trust": 0.6 } }
var-202103-1286
Vulnerability from variot
Certain NETGEAR devices are affected by authentication bypass. This affects RBW30 before 2.6.2.2, RBS40V before 2.6.2.4, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12. plural NETGEAR The product contains an authentication vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBW30 prior to 2.6.2.2, RBS40V prior to 2.6.2.4, RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, RBK753 prior to 3.2.17.12, RBK753S prior to 3.2.17.12, RBK754 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, and RBS750 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1286", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk753", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk754", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbw30", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.2.2" }, { "model": "rbk853", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk753s", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs40v", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.2.4" }, { "model": "rbk854", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk854", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk753s", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbw30", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs40v", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk753", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk853", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004913" }, { "db": "NVD", "id": "CVE-2021-29067" } ] }, "cve": "CVE-2021-29067", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 6.5, "id": "CVE-2021-29067", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 1.9, "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2021-29067", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 9.6, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-004913", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-29067", "trust": 1.0, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2021-29067", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2021-29067", "trust": 0.8, "value": "Critical" }, { "author": "CNNVD", "id": "CNNVD-202103-1361", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-29067", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29067" }, { "db": "JVNDB", "id": "JVNDB-2021-004913" }, { "db": "CNNVD", "id": "CNNVD-202103-1361" }, { "db": "NVD", "id": "CVE-2021-29067" }, { "db": "NVD", "id": "CVE-2021-29067" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by authentication bypass. This affects RBW30 before 2.6.2.2, RBS40V before 2.6.2.4, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12. plural NETGEAR The product contains an authentication vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBW30 prior to 2.6.2.2, RBS40V prior to 2.6.2.4, RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, RBK753 prior to 3.2.17.12, RBK753S prior to 3.2.17.12, RBK754 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, and RBS750 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-29067" }, { "db": "JVNDB", "id": "JVNDB-2021-004913" }, { "db": "VULMON", "id": "CVE-2021-29067" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-29067", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2021-004913", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202103-1361", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-29067", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29067" }, { "db": "JVNDB", "id": "JVNDB-2021-004913" }, { "db": "CNNVD", "id": "CNNVD-202103-1361" }, { "db": "NVD", "id": "CVE-2021-29067" } ] }, "id": "VAR-202103-1286", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.303985029 }, "last_update_date": "2024-11-23T21:58:42.571000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Authentication\u00a0Bypass\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0492", "trust": 0.8, "url": "https://kb.netgear.com/000063017/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0492" }, { "title": "Netgear NETGEAR Remediation measures for authorization problem vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=145682" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004913" }, { "db": "CNNVD", "id": "CNNVD-202103-1361" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "Improper authentication (CWE-287) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004913" }, { "db": "NVD", "id": "CVE-2021-29067" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000063017/security-advisory-for-authentication-bypass-on-some-wifi-systems-psv-2020-0492" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29067" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/287.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29067" }, { "db": "JVNDB", "id": "JVNDB-2021-004913" }, { "db": "CNNVD", "id": "CNNVD-202103-1361" }, { "db": "NVD", "id": "CVE-2021-29067" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-29067" }, { "db": "JVNDB", "id": "JVNDB-2021-004913" }, { "db": "CNNVD", "id": "CNNVD-202103-1361" }, { "db": "NVD", "id": "CVE-2021-29067" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-23T00:00:00", "db": "VULMON", "id": "CVE-2021-29067" }, { "date": "2021-12-02T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-004913" }, { "date": "2021-03-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1361" }, { "date": "2021-03-23T07:15:13.233000", "db": "NVD", "id": "CVE-2021-29067" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-26T00:00:00", "db": "VULMON", "id": "CVE-2021-29067" }, { "date": "2021-12-02T07:19:00", "db": "JVNDB", "id": "JVNDB-2021-004913" }, { "date": "2022-07-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1361" }, { "date": "2024-11-21T06:00:38.160000", "db": "NVD", "id": "CVE-2021-29067" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1361" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Product authentication vulnerabilities", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004913" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "authorization issue", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1361" } ], "trust": 0.6 } }
var-202006-0938
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR On the device OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. Attackers can use this vulnerability to execute arbitrary shell commands on the system with a specially crafted request. This affects RBK752 prior to 3.2.15.25, RBK753 prior to 3.2.15.25, RBK753S prior to 3.2.15.25, RBR750 prior to 3.2.15.25, RBS750 prior to 3.2.15.25, RBK842 prior to 3.2.15.25, RBR840 prior to 3.2.15.25, RBS840 prior to 3.2.15.25, RBK852 prior to 3.2.15.25, RBK853 prior to 3.2.15.25, RBR850 prior to 3.2.15.25, and RBS850 prior to 3.2.15.25
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0938", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk752", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44786" }, { "db": "JVNDB", "id": "JVNDB-2020-006682" }, { "db": "NVD", "id": "CVE-2020-14441" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:netgear:rbk752_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk753_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk753s_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk842_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk852_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk853_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr750_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr840_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs750_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs840_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006682" } ] }, "cve": "CVE-2020-14441", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CVE-2020-14441", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.1, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2020-006682", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CNVD-2021-44786", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2020-14441", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2020-14441", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-006682", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2020-14441", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-14441", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "JVNDB-2020-006682", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-44786", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202006-1260", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2020-14441", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44786" }, { "db": "VULMON", "id": "CVE-2020-14441" }, { "db": "JVNDB", "id": "JVNDB-2020-006682" }, { "db": "CNNVD", "id": "CNNVD-202006-1260" }, { "db": "NVD", "id": "CVE-2020-14441" }, { "db": "NVD", "id": "CVE-2020-14441" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR On the device OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. Attackers can use this vulnerability to execute arbitrary shell commands on the system with a specially crafted request. This affects RBK752 prior to 3.2.15.25, RBK753 prior to 3.2.15.25, RBK753S prior to 3.2.15.25, RBR750 prior to 3.2.15.25, RBS750 prior to 3.2.15.25, RBK842 prior to 3.2.15.25, RBR840 prior to 3.2.15.25, RBS840 prior to 3.2.15.25, RBK852 prior to 3.2.15.25, RBK853 prior to 3.2.15.25, RBR850 prior to 3.2.15.25, and RBS850 prior to 3.2.15.25", "sources": [ { "db": "NVD", "id": "CVE-2020-14441" }, { "db": "JVNDB", "id": "JVNDB-2020-006682" }, { "db": "CNVD", "id": "CNVD-2021-44786" }, { "db": "VULMON", "id": "CVE-2020-14441" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-14441", "trust": 3.1 }, { "db": "JVNDB", "id": "JVNDB-2020-006682", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-44786", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202006-1260", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2020-14441", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44786" }, { "db": "VULMON", "id": "CVE-2020-14441" }, { "db": "JVNDB", "id": "JVNDB-2020-006682" }, { "db": "CNNVD", "id": "CNNVD-202006-1260" }, { "db": "NVD", "id": "CVE-2020-14441" } ] }, "id": "VAR-202006-0938", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-44786" } ], "trust": 1.0097272085714286 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44786" } ] }, "last_update_date": "2024-11-23T22:51:20.508000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Pre-Authentification Command Injection on Some WiFi Systems, PSV-2020-0071", "trust": 0.8, "url": "https://kb.netgear.com/000061946/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0071" }, { "title": "Patch for Operating system command injection vulnerabilities in multiple NETGEAR products (CNVD-2021-44786)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/275051" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44786" }, { "db": "JVNDB", "id": "JVNDB-2020-006682" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "CWE-78", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006682" }, { "db": "NVD", "id": "CVE-2020-14441" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14441" }, { "trust": 1.7, "url": "https://kb.netgear.com/000061946/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0071" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14441" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44786" }, { "db": "VULMON", "id": "CVE-2020-14441" }, { "db": "JVNDB", "id": "JVNDB-2020-006682" }, { "db": "CNNVD", "id": "CNNVD-202006-1260" }, { "db": "NVD", "id": "CVE-2020-14441" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-44786" }, { "db": "VULMON", "id": "CVE-2020-14441" }, { "db": "JVNDB", "id": "JVNDB-2020-006682" }, { "db": "CNNVD", "id": "CNNVD-202006-1260" }, { "db": "NVD", "id": "CVE-2020-14441" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44786" }, { "date": "2020-06-18T00:00:00", "db": "VULMON", "id": "CVE-2020-14441" }, { "date": "2020-07-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006682" }, { "date": "2020-06-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1260" }, { "date": "2020-06-18T17:15:13.233000", "db": "NVD", "id": "CVE-2020-14441" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44786" }, { "date": "2021-07-21T00:00:00", "db": "VULMON", "id": "CVE-2020-14441" }, { "date": "2020-07-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006682" }, { "date": "2020-07-02T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1260" }, { "date": "2024-11-21T05:03:17.100000", "db": "NVD", "id": "CVE-2020-14441" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1260" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR On the device OS Command injection vulnerabilities", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006682" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "operating system commend injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1260" } ], "trust": 0.6 } }
var-202006-0588
Vulnerability from variot
Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR Devices contain vulnerabilities in insufficient protection of credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR.
There are security vulnerabilities in many NETGEAR products. Attackers can use this vulnerability to obtain management credentials
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0588", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk752", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44775" }, { "db": "JVNDB", "id": "JVNDB-2020-006742" }, { "db": "NVD", "id": "CVE-2020-14430" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:netgear:rbk752_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk753_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk753s_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk842_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk852_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk853_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr750_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr840_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr850_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs750_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs840_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs850_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006742" } ] }, "cve": "CVE-2020-14430", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CVE-2020-14430", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "LOW", "trust": 1.0, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "None", "baseScore": 3.3, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2020-006742", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CNVD-2021-44775", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "LOW", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2020-14430", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2020-14430", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-006742", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2020-14430", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-14430", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "JVNDB-2020-006742", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-44775", "trust": 0.6, "value": "LOW" }, { "author": "CNNVD", "id": "CNNVD-202006-1244", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44775" }, { "db": "JVNDB", "id": "JVNDB-2020-006742" }, { "db": "CNNVD", "id": "CNNVD-202006-1244" }, { "db": "NVD", "id": "CVE-2020-14430" }, { "db": "NVD", "id": "CVE-2020-14430" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR Devices contain vulnerabilities in insufficient protection of credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. \n\r\n\r\nThere are security vulnerabilities in many NETGEAR products. Attackers can use this vulnerability to obtain management credentials", "sources": [ { "db": "NVD", "id": "CVE-2020-14430" }, { "db": "JVNDB", "id": "JVNDB-2020-006742" }, { "db": "CNVD", "id": "CNVD-2021-44775" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-14430", "trust": 3.0 }, { "db": "JVNDB", "id": "JVNDB-2020-006742", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-44775", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202006-1244", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44775" }, { "db": "JVNDB", "id": "JVNDB-2020-006742" }, { "db": "CNNVD", "id": "CNNVD-202006-1244" }, { "db": "NVD", "id": "CVE-2020-14430" } ] }, "id": "VAR-202006-0588", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-44775" } ], "trust": 1.0097272085714286 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44775" } ] }, "last_update_date": "2024-11-23T23:11:24.901000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Admin Credential Disclosure on Some WiFi Systems, PSV-2020-0051", "trust": 0.8, "url": "https://kb.netgear.com/000061939/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0051" }, { "title": "Patch for Information Disclosure Vulnerabilities in Multiple NETGEAR Products (CNVD-2021-44775)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/275111" }, { "title": "Multiple NETGEAR Product security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=121992" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44775" }, { "db": "JVNDB", "id": "JVNDB-2020-006742" }, { "db": "CNNVD", "id": "CNNVD-202006-1244" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "CWE-522", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006742" }, { "db": "NVD", "id": "CVE-2020-14430" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14430" }, { "trust": 1.6, "url": "https://kb.netgear.com/000061939/security-advisory-for-admin-credential-disclosure-on-some-wifi-systems-psv-2020-0051" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14430" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44775" }, { "db": "JVNDB", "id": "JVNDB-2020-006742" }, { "db": "CNNVD", "id": "CNNVD-202006-1244" }, { "db": "NVD", "id": "CVE-2020-14430" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-44775" }, { "db": "JVNDB", "id": "JVNDB-2020-006742" }, { "db": "CNNVD", "id": "CNNVD-202006-1244" }, { "db": "NVD", "id": "CVE-2020-14430" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44775" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006742" }, { "date": "2020-06-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1244" }, { "date": "2020-06-18T17:15:12.170000", "db": "NVD", "id": "CVE-2020-14430" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-07-04T00:00:00", "db": "CNVD", "id": "CNVD-2021-44775" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006742" }, { "date": "2020-06-22T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1244" }, { "date": "2024-11-21T05:03:15.150000", "db": "NVD", "id": "CVE-2020-14430" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1244" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR Inadequate protection of credentials on devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006742" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1244" } ], "trust": 0.6 } }
var-202103-1285
Vulnerability from variot
Certain NETGEAR devices are affected by authentication bypass. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR The product contains an authentication vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1285", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk853", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk854", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk854", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk853", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004914" }, { "db": "NVD", "id": "CVE-2021-29066" } ] }, "cve": "CVE-2021-29066", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 6.5, "id": "CVE-2021-29066", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 1.9, "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2021-29066", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 9.6, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-004914", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-29066", "trust": 1.0, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2021-29066", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2021-29066", "trust": 0.8, "value": "Critical" }, { "author": "CNNVD", "id": "CNNVD-202103-1362", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-29066", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29066" }, { "db": "JVNDB", "id": "JVNDB-2021-004914" }, { "db": "CNNVD", "id": "CNNVD-202103-1362" }, { "db": "NVD", "id": "CVE-2021-29066" }, { "db": "NVD", "id": "CVE-2021-29066" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by authentication bypass. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR The product contains an authentication vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-29066" }, { "db": "JVNDB", "id": "JVNDB-2021-004914" }, { "db": "VULMON", "id": "CVE-2021-29066" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-29066", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2021-004914", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202103-1362", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-29066", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29066" }, { "db": "JVNDB", "id": "JVNDB-2021-004914" }, { "db": "CNNVD", "id": "CNNVD-202103-1362" }, { "db": "NVD", "id": "CVE-2021-29066" } ] }, "id": "VAR-202103-1285", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.3648863 }, "last_update_date": "2024-11-23T22:51:05.661000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Authentication\u00a0Bypass\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0484", "trust": 0.8, "url": "https://kb.netgear.com/000063014/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0484" }, { "title": "Netgear NETGEAR Remediation measures for authorization problem vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=145683" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004914" }, { "db": "CNNVD", "id": "CNNVD-202103-1362" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "Improper authentication (CWE-287) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004914" }, { "db": "NVD", "id": "CVE-2021-29066" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000063014/security-advisory-for-authentication-bypass-on-some-wifi-systems-psv-2020-0484" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29066" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/287.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29066" }, { "db": "JVNDB", "id": "JVNDB-2021-004914" }, { "db": "CNNVD", "id": "CNNVD-202103-1362" }, { "db": "NVD", "id": "CVE-2021-29066" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-29066" }, { "db": "JVNDB", "id": "JVNDB-2021-004914" }, { "db": "CNNVD", "id": "CNNVD-202103-1362" }, { "db": "NVD", "id": "CVE-2021-29066" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-23T00:00:00", "db": "VULMON", "id": "CVE-2021-29066" }, { "date": "2021-12-02T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-004914" }, { "date": "2021-03-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1362" }, { "date": "2021-03-23T07:15:13.157000", "db": "NVD", "id": "CVE-2021-29066" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-26T00:00:00", "db": "VULMON", "id": "CVE-2021-29066" }, { "date": "2021-12-02T07:31:00", "db": "JVNDB", "id": "JVNDB-2021-004914" }, { "date": "2022-07-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1362" }, { "date": "2024-11-21T06:00:37.963000", "db": "NVD", "id": "CVE-2021-29066" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1362" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Product authentication vulnerabilities", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004914" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "authorization issue", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1362" } ], "trust": 0.6 } }
var-202006-0931
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, and RBS840 before 3.2.15.25. plural NETGEAR A device contains an injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR.
Injection vulnerabilities exist in many NETGEAR products. The vulnerability stems from the fact that the network system or product lacks the correct verification of the user input data during the operation process of the user inputting the construction command, data structure or record, and the special elements are not filtered or correctly filtered, resulting in the analysis or analysis of the system or product. The explanation is wrong. No detailed vulnerability details are currently provided
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0931", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk752", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44779" }, { "db": "JVNDB", "id": "JVNDB-2020-006745" }, { "db": "NVD", "id": "CVE-2020-14434" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:netgear:rbk752_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk753_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk753s_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk842_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk852_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk853_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr750_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr850_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs750_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs850_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006745" } ] }, "cve": "CVE-2020-14434", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 7.7, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 5.1, "id": "CVE-2020-14434", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 1.0, "vectorString": "AV:A/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 7.7, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "JVNDB-2020-006745", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.7, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 5.1, "id": "CNVD-2021-44779", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "id": "CVE-2020-14434", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "id": "CVE-2020-14434", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-006745", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2020-14434", "trust": 1.0, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2020-14434", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "JVNDB-2020-006745", "trust": 0.8, "value": "Medium" }, { "author": "CNVD", "id": "CNVD-2021-44779", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202006-1250", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44779" }, { "db": "JVNDB", "id": "JVNDB-2020-006745" }, { "db": "CNNVD", "id": "CNNVD-202006-1250" }, { "db": "NVD", "id": "CVE-2020-14434" }, { "db": "NVD", "id": "CVE-2020-14434" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, and RBS840 before 3.2.15.25. plural NETGEAR A device contains an injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. \n\r\n\r\nInjection vulnerabilities exist in many NETGEAR products. The vulnerability stems from the fact that the network system or product lacks the correct verification of the user input data during the operation process of the user inputting the construction command, data structure or record, and the special elements are not filtered or correctly filtered, resulting in the analysis or analysis of the system or product. The explanation is wrong. No detailed vulnerability details are currently provided", "sources": [ { "db": "NVD", "id": "CVE-2020-14434" }, { "db": "JVNDB", "id": "JVNDB-2020-006745" }, { "db": "CNVD", "id": "CNVD-2021-44779" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-14434", "trust": 3.0 }, { "db": "JVNDB", "id": "JVNDB-2020-006745", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-44779", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202006-1250", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44779" }, { "db": "JVNDB", "id": "JVNDB-2020-006745" }, { "db": "CNNVD", "id": "CNNVD-202006-1250" }, { "db": "NVD", "id": "CVE-2020-14434" } ] }, "id": "VAR-202006-0931", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-44779" } ], "trust": 1.0097272085714286 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44779" } ] }, "last_update_date": "2024-11-23T23:01:21.848000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Post-Authentication Command Injection on Some WiFi Systems, PSV-2020-0040", "trust": 0.8, "url": "https://kb.netgear.com/000061934/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0040" }, { "title": "Patch for Command injection vulnerabilities in multiple NETGEAR products (CNVD-2021-44779)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/275091" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44779" }, { "db": "JVNDB", "id": "JVNDB-2020-006745" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "CWE-74", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006745" }, { "db": "NVD", "id": "CVE-2020-14434" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14434" }, { "trust": 1.6, "url": "https://kb.netgear.com/000061934/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0040" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14434" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44779" }, { "db": "JVNDB", "id": "JVNDB-2020-006745" }, { "db": "CNNVD", "id": "CNNVD-202006-1250" }, { "db": "NVD", "id": "CVE-2020-14434" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-44779" }, { "db": "JVNDB", "id": "JVNDB-2020-006745" }, { "db": "CNNVD", "id": "CNNVD-202006-1250" }, { "db": "NVD", "id": "CVE-2020-14434" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44779" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006745" }, { "date": "2020-06-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1250" }, { "date": "2020-06-18T17:15:12.547000", "db": "NVD", "id": "CVE-2020-14434" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44779" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006745" }, { "date": "2020-06-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1250" }, { "date": "2024-11-21T05:03:15.850000", "db": "NVD", "id": "CVE-2020-14434" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1250" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR Injection vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006745" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1250" } ], "trust": 0.6 } }
var-202103-1281
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, RBK753 prior to 3.2.17.12, RBK753S prior to 3.2.17.12, RBK754 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, and RBS750 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1281", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk753", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk754", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk853", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk753s", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk854", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk753s", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk853", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk854", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk753", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk754", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004583" }, { "db": "NVD", "id": "CVE-2021-29078" } ] }, "cve": "CVE-2021-29078", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CVE-2021-29078", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.9, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2021-29078", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 9.6, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-004583", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-29078", "trust": 1.0, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2021-29078", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2021-29078", "trust": 0.8, "value": "Critical" }, { "author": "CNNVD", "id": "CNNVD-202103-1345", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-29078", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29078" }, { "db": "JVNDB", "id": "JVNDB-2021-004583" }, { "db": "CNNVD", "id": "CNNVD-202103-1345" }, { "db": "NVD", "id": "CVE-2021-29078" }, { "db": "NVD", "id": "CVE-2021-29078" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, RBK753 prior to 3.2.17.12, RBK753S prior to 3.2.17.12, RBK754 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, and RBS750 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-29078" }, { "db": "JVNDB", "id": "JVNDB-2021-004583" }, { "db": "VULMON", "id": "CVE-2021-29078" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-29078", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2021-004583", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202103-1345", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-29078", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29078" }, { "db": "JVNDB", "id": "JVNDB-2021-004583" }, { "db": "CNNVD", "id": "CNNVD-202103-1345" }, { "db": "NVD", "id": "CVE-2021-29078" } ] }, "id": "VAR-202103-1281", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.35096342999999997 }, "last_update_date": "2024-11-23T22:47:40.243000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0511", "trust": 0.8, "url": "https://kb.netgear.com/000063009/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0511" }, { "title": "NETGEAR Repair measures for command injection vulnerabilities in multiple products", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=145161" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004583" }, { "db": "CNNVD", "id": "CNNVD-202103-1345" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004583" }, { "db": "NVD", "id": "CVE-2021-29078" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000063009/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0511" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29078" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29078" }, { "db": "JVNDB", "id": "JVNDB-2021-004583" }, { "db": "CNNVD", "id": "CNNVD-202103-1345" }, { "db": "NVD", "id": "CVE-2021-29078" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-29078" }, { "db": "JVNDB", "id": "JVNDB-2021-004583" }, { "db": "CNNVD", "id": "CNNVD-202103-1345" }, { "db": "NVD", "id": "CVE-2021-29078" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-23T00:00:00", "db": "VULMON", "id": "CVE-2021-29078" }, { "date": "2021-11-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-004583" }, { "date": "2021-03-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1345" }, { "date": "2021-03-23T07:15:14.077000", "db": "NVD", "id": "CVE-2021-29078" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-24T00:00:00", "db": "VULMON", "id": "CVE-2021-29078" }, { "date": "2021-11-25T03:10:00", "db": "JVNDB", "id": "JVNDB-2021-004583" }, { "date": "2021-08-16T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1345" }, { "date": "2024-11-21T06:00:40.030000", "db": "NVD", "id": "CVE-2021-29078" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1345" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004583" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1345" } ], "trust": 0.6 } }
var-202006-0587
Vulnerability from variot
Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects MK62 before 1.0.4.92, MK63 before 1.0.4.92, MR60 before 1.0.4.92, MS60 before 1.0.4.92, RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBS750 before 3.2.15.25, RBR750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR Devices contain vulnerabilities in insufficient protection of credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. This affects MK62 prior to 1.0.4.92, MK63 prior to 1.0.4.92, MR60 prior to 1.0.4.92, MS60 prior to 1.0.4.92, RBK752 prior to 3.2.15.25, RBK753 prior to 3.2.15.25, RBK753S prior to 3.2.15.25, RBS750 prior to 3.2.15.25, RBR750 prior to 3.2.15.25, RBK842 prior to 3.2.15.25, RBR840 prior to 3.2.15.25, RBS840 prior to 3.2.15.25, RBK852 prior to 3.2.15.25, RBK853 prior to 3.2.15.25, RBR850 prior to 3.2.15.25, and RBS850 prior to 3.2.15.25
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0587", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "mk63", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.92" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "ms60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.92" }, { "model": "rbk753s", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "mr60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.92" }, { "model": "mk62", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.92" }, { "model": "rbk842", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "mk62", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.4.92" }, { "model": "mk63", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.4.92" }, { "model": "mr60", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.4.92" }, { "model": "ms60", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.4.92" }, { "model": "rbk752", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006746" }, { "db": "NVD", "id": "CVE-2020-14429" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:netgear:mk62_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:mk63_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:mr60_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:ms60_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk752_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk753_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk753s_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk842_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr750_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs750_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006746" } ] }, "cve": "CVE-2020-14429", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CVE-2020-14429", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.1, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2020-006746", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2020-14429", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2020-14429", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-006746", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2020-14429", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-14429", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "JVNDB-2020-006746", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-202006-1243", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2020-14429", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2020-14429" }, { "db": "JVNDB", "id": "JVNDB-2020-006746" }, { "db": "CNNVD", "id": "CNNVD-202006-1243" }, { "db": "NVD", "id": "CVE-2020-14429" }, { "db": "NVD", "id": "CVE-2020-14429" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects MK62 before 1.0.4.92, MK63 before 1.0.4.92, MR60 before 1.0.4.92, MS60 before 1.0.4.92, RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBS750 before 3.2.15.25, RBR750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR Devices contain vulnerabilities in insufficient protection of credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. This affects MK62 prior to 1.0.4.92, MK63 prior to 1.0.4.92, MR60 prior to 1.0.4.92, MS60 prior to 1.0.4.92, RBK752 prior to 3.2.15.25, RBK753 prior to 3.2.15.25, RBK753S prior to 3.2.15.25, RBS750 prior to 3.2.15.25, RBR750 prior to 3.2.15.25, RBK842 prior to 3.2.15.25, RBR840 prior to 3.2.15.25, RBS840 prior to 3.2.15.25, RBK852 prior to 3.2.15.25, RBK853 prior to 3.2.15.25, RBR850 prior to 3.2.15.25, and RBS850 prior to 3.2.15.25", "sources": [ { "db": "NVD", "id": "CVE-2020-14429" }, { "db": "JVNDB", "id": "JVNDB-2020-006746" }, { "db": "VULMON", "id": "CVE-2020-14429" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-14429", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2020-006746", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202006-1243", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2020-14429", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2020-14429" }, { "db": "JVNDB", "id": "JVNDB-2020-006746" }, { "db": "CNNVD", "id": "CNNVD-202006-1243" }, { "db": "NVD", "id": "CVE-2020-14429" } ] }, "id": "VAR-202006-0587", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.4097272085714286 }, "last_update_date": "2024-11-23T22:33:26.219000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Admin Credential Disclosure on Some WiFi Systems, PSV-2020-0050", "trust": 0.8, "url": "https://kb.netgear.com/000061938/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0050" }, { "title": "Multiple NETGEAR Product security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=121991" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006746" }, { "db": "CNNVD", "id": "CNNVD-202006-1243" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "CWE-522", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006746" }, { "db": "NVD", "id": "CVE-2020-14429" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000061938/security-advisory-for-admin-credential-disclosure-on-some-wifi-systems-psv-2020-0050" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14429" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14429" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2020-14429" }, { "db": "JVNDB", "id": "JVNDB-2020-006746" }, { "db": "CNNVD", "id": "CNNVD-202006-1243" }, { "db": "NVD", "id": "CVE-2020-14429" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2020-14429" }, { "db": "JVNDB", "id": "JVNDB-2020-006746" }, { "db": "CNNVD", "id": "CNNVD-202006-1243" }, { "db": "NVD", "id": "CVE-2020-14429" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-18T00:00:00", "db": "VULMON", "id": "CVE-2020-14429" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006746" }, { "date": "2020-06-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1243" }, { "date": "2020-06-18T17:15:12.077000", "db": "NVD", "id": "CVE-2020-14429" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-07-21T00:00:00", "db": "VULMON", "id": "CVE-2020-14429" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006746" }, { "date": "2020-06-22T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1243" }, { "date": "2024-11-21T05:03:14.980000", "db": "NVD", "id": "CVE-2020-14429" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1243" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR Inadequate protection of credentials on devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006746" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1243" } ], "trust": 0.6 } }
var-202103-1280
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBW30 before 2.6.2.2, RBS40V before 2.6.2.4, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBW30 prior to 2.6.2.2, RBS40V prior to 2.6.2.4, RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, RBK753 prior to 3.2.17.12, RBK753S prior to 3.2.17.12, RBK754 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, and RBS750 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1280", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk753", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk754", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbw30", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.2.2" }, { "model": "rbk853", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk753s", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs40v", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.2.4" }, { "model": "rbk854", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk753s", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk853", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbw30", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk854", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk753", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs40v", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004582" }, { "db": "NVD", "id": "CVE-2021-29077" } ] }, "cve": "CVE-2021-29077", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CVE-2021-29077", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.9, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2021-29077", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 9.6, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-004582", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-29077", "trust": 1.0, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2021-29077", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2021-29077", "trust": 0.8, "value": "Critical" }, { "author": "CNNVD", "id": "CNNVD-202103-1346", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-29077", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29077" }, { "db": "JVNDB", "id": "JVNDB-2021-004582" }, { "db": "CNNVD", "id": "CNNVD-202103-1346" }, { "db": "NVD", "id": "CVE-2021-29077" }, { "db": "NVD", "id": "CVE-2021-29077" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBW30 before 2.6.2.2, RBS40V before 2.6.2.4, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBW30 prior to 2.6.2.2, RBS40V prior to 2.6.2.4, RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, RBK753 prior to 3.2.17.12, RBK753S prior to 3.2.17.12, RBK754 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, and RBS750 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-29077" }, { "db": "JVNDB", "id": "JVNDB-2021-004582" }, { "db": "VULMON", "id": "CVE-2021-29077" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-29077", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2021-004582", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202103-1346", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-29077", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29077" }, { "db": "JVNDB", "id": "JVNDB-2021-004582" }, { "db": "CNNVD", "id": "CNNVD-202103-1346" }, { "db": "NVD", "id": "CVE-2021-29077" } ] }, "id": "VAR-202103-1280", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.303985029 }, "last_update_date": "2024-11-23T22:33:06.393000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0486", "trust": 0.8, "url": "https://kb.netgear.com/000063016/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0486" }, { "title": "NETGEAR Repair measures for command injection vulnerabilities in multiple products", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=145162" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004582" }, { "db": "CNNVD", "id": "CNNVD-202103-1346" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004582" }, { "db": "NVD", "id": "CVE-2021-29077" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000063016/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0486" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29077" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29077" }, { "db": "JVNDB", "id": "JVNDB-2021-004582" }, { "db": "CNNVD", "id": "CNNVD-202103-1346" }, { "db": "NVD", "id": "CVE-2021-29077" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-29077" }, { "db": "JVNDB", "id": "JVNDB-2021-004582" }, { "db": "CNNVD", "id": "CNNVD-202103-1346" }, { "db": "NVD", "id": "CVE-2021-29077" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-23T00:00:00", "db": "VULMON", "id": "CVE-2021-29077" }, { "date": "2021-11-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-004582" }, { "date": "2021-03-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1346" }, { "date": "2021-03-23T07:15:14.013000", "db": "NVD", "id": "CVE-2021-29077" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-24T00:00:00", "db": "VULMON", "id": "CVE-2021-29077" }, { "date": "2021-11-25T03:10:00", "db": "JVNDB", "id": "JVNDB-2021-004582" }, { "date": "2021-08-16T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1346" }, { "date": "2024-11-21T06:00:39.877000", "db": "NVD", "id": "CVE-2021-29077" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1346" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004582" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1346" } ], "trust": 0.6 } }
var-202006-0936
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR On the device OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. Attackers can use this vulnerability to execute arbitrary Shell commands on the system by sending a specially crafted request
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0936", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk752", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44784" }, { "db": "JVNDB", "id": "JVNDB-2020-006686" }, { "db": "NVD", "id": "CVE-2020-14439" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:netgear:rbk752_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk753_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk753s_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk842_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk852_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk853_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr750_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr840_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs750_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs840_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006686" } ] }, "cve": "CVE-2020-14439", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CVE-2020-14439", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.0, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2020-006686", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CNVD-2021-44784", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2020-14439", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2020-14439", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-006686", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2020-14439", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-14439", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "JVNDB-2020-006686", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-44784", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202006-1256", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44784" }, { "db": "JVNDB", "id": "JVNDB-2020-006686" }, { "db": "CNNVD", "id": "CNNVD-202006-1256" }, { "db": "NVD", "id": "CVE-2020-14439" }, { "db": "NVD", "id": "CVE-2020-14439" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR On the device OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. Attackers can use this vulnerability to execute arbitrary Shell commands on the system by sending a specially crafted request", "sources": [ { "db": "NVD", "id": "CVE-2020-14439" }, { "db": "JVNDB", "id": "JVNDB-2020-006686" }, { "db": "CNVD", "id": "CNVD-2021-44784" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-14439", "trust": 3.0 }, { "db": "JVNDB", "id": "JVNDB-2020-006686", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-44784", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202006-1256", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44784" }, { "db": "JVNDB", "id": "JVNDB-2020-006686" }, { "db": "CNNVD", "id": "CNNVD-202006-1256" }, { "db": "NVD", "id": "CVE-2020-14439" } ] }, "id": "VAR-202006-0936", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-44784" } ], "trust": 1.0097272085714286 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44784" } ] }, "last_update_date": "2024-11-23T22:05:37.103000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Pre-Authentification Command Injection on Some WiFi Systems, PSV-2020-0064", "trust": 0.8, "url": "https://kb.netgear.com/000061942/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0064" }, { "title": "Patch for Operating system command injection vulnerabilities in multiple NETGEAR products (CNVD-2021-44784)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/275031" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44784" }, { "db": "JVNDB", "id": "JVNDB-2020-006686" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "CWE-78", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006686" }, { "db": "NVD", "id": "CVE-2020-14439" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14439" }, { "trust": 1.6, "url": "https://kb.netgear.com/000061942/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0064" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14439" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44784" }, { "db": "JVNDB", "id": "JVNDB-2020-006686" }, { "db": "CNNVD", "id": "CNNVD-202006-1256" }, { "db": "NVD", "id": "CVE-2020-14439" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-44784" }, { "db": "JVNDB", "id": "JVNDB-2020-006686" }, { "db": "CNNVD", "id": "CNNVD-202006-1256" }, { "db": "NVD", "id": "CVE-2020-14439" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44784" }, { "date": "2020-07-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006686" }, { "date": "2020-06-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1256" }, { "date": "2020-06-18T17:15:13.047000", "db": "NVD", "id": "CVE-2020-14439" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44784" }, { "date": "2020-07-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006686" }, { "date": "2020-07-02T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1256" }, { "date": "2024-11-21T05:03:16.763000", "db": "NVD", "id": "CVE-2020-14439" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1256" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR On the device OS Command injection vulnerabilities", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006686" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "operating system commend injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1256" } ], "trust": 0.6 } }
var-202103-1283
Vulnerability from variot
Certain NETGEAR devices are affected by password reset by an unauthenticated attacker. This affects RBK852 before 3.2.10.11, RBK853 before 3.2.10.11, RBR854 before 3.2.10.11, RBR850 before 3.2.10.11, RBS850 before 3.2.10.11, CBR40 before 2.5.0.10, R7000 before 1.0.11.116, R6900P before 1.3.2.126, R7900 before 1.0.4.38, R7960P before 1.4.1.66, R8000 before 1.0.4.66, R7900P before 1.4.1.66, R8000P before 1.4.1.66, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, and R7000P before 1.3.2.126. plural NETGEAR A vulnerability exists in the device regarding the password management function.Information may be obtained and information may be tampered with. This affects RBK852 prior to 3.2.10.11, RBK853 prior to 3.2.10.11, RBR854 prior to 3.2.10.11, RBR850 prior to 3.2.10.11, RBS850 prior to 3.2.10.11, CBR40 prior to 2.5.0.10, R7000 prior to 1.0.11.116, R6900P prior to 1.3.2.126, R7900 prior to 1.0.4.38, R7960P prior to 1.4.1.66, R8000 prior to 1.0.4.66, R7900P prior to 1.4.1.66, R8000P prior to 1.4.1.66, RAX75 prior to 1.0.3.102, RAX80 prior to 1.0.3.102, and R7000P prior to 1.3.2.126
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1283", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.10" }, { "model": "r8000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.66" }, { "model": "r7960p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.66" }, { "model": "r7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.11.116" }, { "model": "r6900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.2.126" }, { "model": "rbk853", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.102" }, { "model": "r7000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.2.126" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.102" }, { "model": "r7900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.38" }, { "model": "r8000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.66" }, { "model": "r7900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.66" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbr854", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk853", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr854", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7900", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r6900p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7960p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7000", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004585" }, { "db": "NVD", "id": "CVE-2021-29080" } ] }, "cve": "CVE-2021-29080", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 4.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CVE-2021-29080", "impactScore": 4.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.9, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2021-29080", "impactScore": 5.2, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "OTHER", "availabilityImpact": "None", "baseScore": 8.1, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-004585", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-29080", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-29080", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2021-29080", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-202103-1343", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-29080", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29080" }, { "db": "JVNDB", "id": "JVNDB-2021-004585" }, { "db": "CNNVD", "id": "CNNVD-202103-1343" }, { "db": "NVD", "id": "CVE-2021-29080" }, { "db": "NVD", "id": "CVE-2021-29080" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by password reset by an unauthenticated attacker. This affects RBK852 before 3.2.10.11, RBK853 before 3.2.10.11, RBR854 before 3.2.10.11, RBR850 before 3.2.10.11, RBS850 before 3.2.10.11, CBR40 before 2.5.0.10, R7000 before 1.0.11.116, R6900P before 1.3.2.126, R7900 before 1.0.4.38, R7960P before 1.4.1.66, R8000 before 1.0.4.66, R7900P before 1.4.1.66, R8000P before 1.4.1.66, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, and R7000P before 1.3.2.126. plural NETGEAR A vulnerability exists in the device regarding the password management function.Information may be obtained and information may be tampered with. This affects RBK852 prior to 3.2.10.11, RBK853 prior to 3.2.10.11, RBR854 prior to 3.2.10.11, RBR850 prior to 3.2.10.11, RBS850 prior to 3.2.10.11, CBR40 prior to 2.5.0.10, R7000 prior to 1.0.11.116, R6900P prior to 1.3.2.126, R7900 prior to 1.0.4.38, R7960P prior to 1.4.1.66, R8000 prior to 1.0.4.66, R7900P prior to 1.4.1.66, R8000P prior to 1.4.1.66, RAX75 prior to 1.0.3.102, RAX80 prior to 1.0.3.102, and R7000P prior to 1.3.2.126", "sources": [ { "db": "NVD", "id": "CVE-2021-29080" }, { "db": "JVNDB", "id": "JVNDB-2021-004585" }, { "db": "VULMON", "id": "CVE-2021-29080" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-29080", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2021-004585", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202103-1343", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-29080", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29080" }, { "db": "JVNDB", "id": "JVNDB-2021-004585" }, { "db": "CNNVD", "id": "CNNVD-202103-1343" }, { "db": "NVD", "id": "CVE-2021-29080" } ] }, "id": "VAR-202103-1283", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.32459724375000004 }, "last_update_date": "2024-11-23T22:57:57.955000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-authentication\u00a0Password\u00a0Reset\u00a0on\u00a0Some\u00a0Routers\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2019-0150", "trust": 0.8, "url": "https://kb.netgear.com/000063007/Security-Advisory-for-Pre-authentication-Password-Reset-on-Some-Routers-and-WiFi-Systems-PSV-2019-0150" }, { "title": "Certain NETGEAR Remediation measures for authorization problem vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=145159" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004585" }, { "db": "CNNVD", "id": "CNNVD-202103-1343" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-640", "trust": 1.0 }, { "problemtype": "Weak password recovery mechanism when you forget your password (CWE-640) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004585" }, { "db": "NVD", "id": "CVE-2021-29080" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000063007/security-advisory-for-pre-authentication-password-reset-on-some-routers-and-wifi-systems-psv-2019-0150" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29080" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/640.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29080" }, { "db": "JVNDB", "id": "JVNDB-2021-004585" }, { "db": "CNNVD", "id": "CNNVD-202103-1343" }, { "db": "NVD", "id": "CVE-2021-29080" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-29080" }, { "db": "JVNDB", "id": "JVNDB-2021-004585" }, { "db": "CNNVD", "id": "CNNVD-202103-1343" }, { "db": "NVD", "id": "CVE-2021-29080" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-23T00:00:00", "db": "VULMON", "id": "CVE-2021-29080" }, { "date": "2021-11-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-004585" }, { "date": "2021-03-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1343" }, { "date": "2021-03-23T07:15:14.217000", "db": "NVD", "id": "CVE-2021-29080" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-24T00:00:00", "db": "VULMON", "id": "CVE-2021-29080" }, { "date": "2021-11-25T03:10:00", "db": "JVNDB", "id": "JVNDB-2021-004585" }, { "date": "2021-08-16T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1343" }, { "date": "2024-11-21T06:00:40.337000", "db": "NVD", "id": "CVE-2021-29080" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1343" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Vulnerability related to password management function in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004585" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "authorization issue", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1343" } ], "trust": 0.6 } }
var-202006-0929
Vulnerability from variot
Certain NETGEAR devices are affected by CSRF. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR A cross-site request forgery vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. The vulnerability stems from the fact that the WEB application does not fully verify whether the request comes from a trusted user. An attacker can use this vulnerability to send unexpected requests to the server through the affected client
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0929", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk752", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44777" }, { "db": "JVNDB", "id": "JVNDB-2020-006797" }, { "db": "NVD", "id": "CVE-2020-14432" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:netgear:rbk752_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk753_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk753s_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk842_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk852_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk853_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr750_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr840_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs750_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs840_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006797" } ] }, "cve": "CVE-2020-14432", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "CVE-2020-14432", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.0, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Medium", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 6.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2020-006797", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "CNVD-2021-44777", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2020-14432", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "id": "CVE-2020-14432", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-006797", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2020-14432", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-14432", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "JVNDB-2020-006797", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-44777", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202006-1247", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44777" }, { "db": "JVNDB", "id": "JVNDB-2020-006797" }, { "db": "CNNVD", "id": "CNNVD-202006-1247" }, { "db": "NVD", "id": "CVE-2020-14432" }, { "db": "NVD", "id": "CVE-2020-14432" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by CSRF. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR A cross-site request forgery vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. The vulnerability stems from the fact that the WEB application does not fully verify whether the request comes from a trusted user. An attacker can use this vulnerability to send unexpected requests to the server through the affected client", "sources": [ { "db": "NVD", "id": "CVE-2020-14432" }, { "db": "JVNDB", "id": "JVNDB-2020-006797" }, { "db": "CNVD", "id": "CNVD-2021-44777" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-14432", "trust": 3.0 }, { "db": "JVNDB", "id": "JVNDB-2020-006797", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-44777", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202006-1247", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44777" }, { "db": "JVNDB", "id": "JVNDB-2020-006797" }, { "db": "CNNVD", "id": "CNNVD-202006-1247" }, { "db": "NVD", "id": "CVE-2020-14432" } ] }, "id": "VAR-202006-0929", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-44777" } ], "trust": 1.0097272085714286 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44777" } ] }, "last_update_date": "2024-11-23T22:16:27.342000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Cross Site Request Forgery on Some WiFi Systems, PSV-2020-0049", "trust": 0.8, "url": "https://kb.netgear.com/000061937/Security-Advisory-for-Cross-Site-Request-Forgery-on-Some-WiFi-Systems-PSV-2020-0049" }, { "title": "Patch for Cross-site request forgery vulnerabilities in multiple NETGEAR products (CNVD-2021-44777)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/275101" }, { "title": "Multiple NETGEAR Repair measures for product cross-site request forgery vulnerability", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=121995" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44777" }, { "db": "JVNDB", "id": "JVNDB-2020-006797" }, { "db": "CNNVD", "id": "CNNVD-202006-1247" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-352", "trust": 1.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006797" }, { "db": "NVD", "id": "CVE-2020-14432" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14432" }, { "trust": 1.6, "url": "https://kb.netgear.com/000061937/security-advisory-for-cross-site-request-forgery-on-some-wifi-systems-psv-2020-0049" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14432" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44777" }, { "db": "JVNDB", "id": "JVNDB-2020-006797" }, { "db": "CNNVD", "id": "CNNVD-202006-1247" }, { "db": "NVD", "id": "CVE-2020-14432" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-44777" }, { "db": "JVNDB", "id": "JVNDB-2020-006797" }, { "db": "CNNVD", "id": "CNNVD-202006-1247" }, { "db": "NVD", "id": "CVE-2020-14432" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44777" }, { "date": "2020-07-17T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006797" }, { "date": "2020-06-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1247" }, { "date": "2020-06-18T17:15:12.327000", "db": "NVD", "id": "CVE-2020-14432" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44777" }, { "date": "2020-07-17T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006797" }, { "date": "2020-06-30T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1247" }, { "date": "2024-11-21T05:03:15.507000", "db": "NVD", "id": "CVE-2020-14432" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1247" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR Cross-site request forgery vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006797" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "cross-site request forgery", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1247" } ], "trust": 0.6 } }
var-202103-1273
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR The product contains a command injection vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1273", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk853", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk854", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk854", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk853", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004910" }, { "db": "NVD", "id": "CVE-2021-29070" } ] }, "cve": "CVE-2021-29070", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "id": "CVE-2021-29070", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.9, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "id": "CVE-2021-29070", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 8.4, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-004910", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-29070", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-29070", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2021-29070", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-202103-1358", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-29070", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29070" }, { "db": "JVNDB", "id": "JVNDB-2021-004910" }, { "db": "CNNVD", "id": "CNNVD-202103-1358" }, { "db": "NVD", "id": "CVE-2021-29070" }, { "db": "NVD", "id": "CVE-2021-29070" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR The product contains a command injection vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-29070" }, { "db": "JVNDB", "id": "JVNDB-2021-004910" }, { "db": "VULMON", "id": "CVE-2021-29070" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-29070", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2021-004910", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202103-1358", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-29070", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29070" }, { "db": "JVNDB", "id": "JVNDB-2021-004910" }, { "db": "CNNVD", "id": "CNNVD-202103-1358" }, { "db": "NVD", "id": "CVE-2021-29070" } ] }, "id": "VAR-202103-1273", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.3648863 }, "last_update_date": "2024-11-23T22:11:05.212000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Routers,\u00a0PSV-2020-0530", "trust": 0.8, "url": "https://kb.netgear.com/000063019/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Routers-PSV-2020-0530" }, { "title": "Netgear NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=145680" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004910" }, { "db": "CNNVD", "id": "CNNVD-202103-1358" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004910" }, { "db": "NVD", "id": "CVE-2021-29070" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000063019/security-advisory-for-post-authentication-command-injection-on-some-wifi-routers-psv-2020-0530" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29070" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29070" }, { "db": "JVNDB", "id": "JVNDB-2021-004910" }, { "db": "CNNVD", "id": "CNNVD-202103-1358" }, { "db": "NVD", "id": "CVE-2021-29070" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-29070" }, { "db": "JVNDB", "id": "JVNDB-2021-004910" }, { "db": "CNNVD", "id": "CNNVD-202103-1358" }, { "db": "NVD", "id": "CVE-2021-29070" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-23T00:00:00", "db": "VULMON", "id": "CVE-2021-29070" }, { "date": "2021-12-02T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-004910" }, { "date": "2021-03-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1358" }, { "date": "2021-03-23T07:15:13.483000", "db": "NVD", "id": "CVE-2021-29070" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-26T00:00:00", "db": "VULMON", "id": "CVE-2021-29070" }, { "date": "2021-12-02T06:31:00", "db": "JVNDB", "id": "JVNDB-2021-004910" }, { "date": "2021-03-30T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1358" }, { "date": "2024-11-21T06:00:38.747000", "db": "NVD", "id": "CVE-2021-29070" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1358" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerabilities in the product", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004910" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1358" } ], "trust": 0.6 } }
var-202006-0584
Vulnerability from variot
Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBK853 before 3.2.10.11, RBR850 before 3.2.10.11, RBS850 before 3.2.10.11, RBK842 before 3.2.10.11, RBR840 before 3.2.10.11, and RBS840 before 3.2.10.11. plural NETGEAR Devices contain vulnerabilities in insufficient protection of credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR.
There are security vulnerabilities in many NETGEAR products. Attackers can use this vulnerability to obtain management credentials. This affects RBK752 prior to 3.2.15.25, RBK753 prior to 3.2.15.25, RBK753S prior to 3.2.15.25, RBR750 prior to 3.2.15.25, RBS750 prior to 3.2.15.25, RBK852 prior to 3.2.10.11, RBK853 prior to 3.2.10.11, RBR850 prior to 3.2.10.11, RBS850 prior to 3.2.10.11, RBK842 prior to 3.2.10.11, RBR840 prior to 3.2.10.11, and RBS840 prior to 3.2.10.11
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0584", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk752", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbs840", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbk853", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbk842", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbr840", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbk752", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbk852", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbk853", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbr750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbr850", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbs750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbs850", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbk842", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "3.2.15.25" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44773" }, { "db": "JVNDB", "id": "JVNDB-2020-006747" }, { "db": "NVD", "id": "CVE-2020-14426" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:netgear:rbk752_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk753_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk753s_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk842_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk852_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk853_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr750_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr840_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr850_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs750_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs840_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs850_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006747" } ] }, "cve": "CVE-2020-14426", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CVE-2020-14426", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "LOW", "trust": 1.1, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "None", "baseScore": 3.3, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2020-006747", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CNVD-2021-44773", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "LOW", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2020-14426", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2020-14426", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-006747", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2020-14426", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-14426", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "JVNDB-2020-006747", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-44773", "trust": 0.6, "value": "LOW" }, { "author": "CNNVD", "id": "CNNVD-202006-1239", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2020-14426", "trust": 0.1, "value": "LOW" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44773" }, { "db": "VULMON", "id": "CVE-2020-14426" }, { "db": "JVNDB", "id": "JVNDB-2020-006747" }, { "db": "CNNVD", "id": "CNNVD-202006-1239" }, { "db": "NVD", "id": "CVE-2020-14426" }, { "db": "NVD", "id": "CVE-2020-14426" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBK853 before 3.2.10.11, RBR850 before 3.2.10.11, RBS850 before 3.2.10.11, RBK842 before 3.2.10.11, RBR840 before 3.2.10.11, and RBS840 before 3.2.10.11. plural NETGEAR Devices contain vulnerabilities in insufficient protection of credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. \n\r\n\r\nThere are security vulnerabilities in many NETGEAR products. Attackers can use this vulnerability to obtain management credentials. This affects RBK752 prior to 3.2.15.25, RBK753 prior to 3.2.15.25, RBK753S prior to 3.2.15.25, RBR750 prior to 3.2.15.25, RBS750 prior to 3.2.15.25, RBK852 prior to 3.2.10.11, RBK853 prior to 3.2.10.11, RBR850 prior to 3.2.10.11, RBS850 prior to 3.2.10.11, RBK842 prior to 3.2.10.11, RBR840 prior to 3.2.10.11, and RBS840 prior to 3.2.10.11", "sources": [ { "db": "NVD", "id": "CVE-2020-14426" }, { "db": "JVNDB", "id": "JVNDB-2020-006747" }, { "db": "CNVD", "id": "CNVD-2021-44773" }, { "db": "VULMON", "id": "CVE-2020-14426" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-14426", "trust": 3.1 }, { "db": "JVNDB", "id": "JVNDB-2020-006747", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-44773", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202006-1239", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2020-14426", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44773" }, { "db": "VULMON", "id": "CVE-2020-14426" }, { "db": "JVNDB", "id": "JVNDB-2020-006747" }, { "db": "CNNVD", "id": "CNNVD-202006-1239" }, { "db": "NVD", "id": "CVE-2020-14426" } ] }, "id": "VAR-202006-0584", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-44773" } ], "trust": 1.0097272085714286 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44773" } ] }, "last_update_date": "2024-11-23T22:11:28.237000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Admin Credential Disclosure on Some Wifi Systems, PSV-2020-0033", "trust": 0.8, "url": "https://kb.netgear.com/000061931/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-Wifi-Systems-PSV-2020-0033" }, { "title": "Patch for Information Disclosure Vulnerabilities in Multiple NETGEAR Products (CNVD-2021-44773)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/275071" }, { "title": "Multiple NETGEAR Product security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=121988" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44773" }, { "db": "JVNDB", "id": "JVNDB-2020-006747" }, { "db": "CNNVD", "id": "CNNVD-202006-1239" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "CWE-522", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006747" }, { "db": "NVD", "id": "CVE-2020-14426" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14426" }, { "trust": 1.7, "url": "https://kb.netgear.com/000061931/security-advisory-for-admin-credential-disclosure-on-some-wifi-systems-psv-2020-0033" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14426" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44773" }, { "db": "VULMON", "id": "CVE-2020-14426" }, { "db": "JVNDB", "id": "JVNDB-2020-006747" }, { "db": "CNNVD", "id": "CNNVD-202006-1239" }, { "db": "NVD", "id": "CVE-2020-14426" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-44773" }, { "db": "VULMON", "id": "CVE-2020-14426" }, { "db": "JVNDB", "id": "JVNDB-2020-006747" }, { "db": "CNNVD", "id": "CNNVD-202006-1239" }, { "db": "NVD", "id": "CVE-2020-14426" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44773" }, { "date": "2020-06-18T00:00:00", "db": "VULMON", "id": "CVE-2020-14426" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006747" }, { "date": "2020-06-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1239" }, { "date": "2020-06-18T17:15:11.813000", "db": "NVD", "id": "CVE-2020-14426" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44773" }, { "date": "2021-07-21T00:00:00", "db": "VULMON", "id": "CVE-2020-14426" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006747" }, { "date": "2020-06-22T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1239" }, { "date": "2024-11-21T05:03:14.453000", "db": "NVD", "id": "CVE-2020-14426" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1239" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR Inadequate protection of credentials on devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006747" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1239" } ], "trust": 0.6 } }
var-202103-1275
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1275", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk853", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk854", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk853", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk854", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004578" }, { "db": "NVD", "id": "CVE-2021-29072" } ] }, "cve": "CVE-2021-29072", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "id": "CVE-2021-29072", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.9, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "id": "CVE-2021-29072", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 8.4, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-004578", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-29072", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-29072", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2021-29072", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-202103-1354", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-29072", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29072" }, { "db": "JVNDB", "id": "JVNDB-2021-004578" }, { "db": "CNNVD", "id": "CNNVD-202103-1354" }, { "db": "NVD", "id": "CVE-2021-29072" }, { "db": "NVD", "id": "CVE-2021-29072" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-29072" }, { "db": "JVNDB", "id": "JVNDB-2021-004578" }, { "db": "VULMON", "id": "CVE-2021-29072" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-29072", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2021-004578", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202103-1354", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-29072", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29072" }, { "db": "JVNDB", "id": "JVNDB-2021-004578" }, { "db": "CNNVD", "id": "CNNVD-202103-1354" }, { "db": "NVD", "id": "CVE-2021-29072" } ] }, "id": "VAR-202103-1275", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.3648863 }, "last_update_date": "2024-11-23T23:07:37.983000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0493", "trust": 0.8, "url": "https://kb.netgear.com/000063018/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0493" }, { "title": "Certain NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=144972" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004578" }, { "db": "CNNVD", "id": "CNNVD-202103-1354" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004578" }, { "db": "NVD", "id": "CVE-2021-29072" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000063018/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0493" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29072" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29072" }, { "db": "JVNDB", "id": "JVNDB-2021-004578" }, { "db": "CNNVD", "id": "CNNVD-202103-1354" }, { "db": "NVD", "id": "CVE-2021-29072" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-29072" }, { "db": "JVNDB", "id": "JVNDB-2021-004578" }, { "db": "CNNVD", "id": "CNNVD-202103-1354" }, { "db": "NVD", "id": "CVE-2021-29072" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-23T00:00:00", "db": "VULMON", "id": "CVE-2021-29072" }, { "date": "2021-11-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-004578" }, { "date": "2021-03-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1354" }, { "date": "2021-03-23T07:15:13.640000", "db": "NVD", "id": "CVE-2021-29072" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-24T00:00:00", "db": "VULMON", "id": "CVE-2021-29072" }, { "date": "2021-11-25T03:10:00", "db": "JVNDB", "id": "JVNDB-2021-004578" }, { "date": "2021-08-16T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1354" }, { "date": "2024-11-21T06:00:39.080000", "db": "NVD", "id": "CVE-2021-29072" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1354" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004578" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1354" } ], "trust": 0.6 } }
var-202103-1277
Vulnerability from variot
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects RBW30 before 2.6.2.2, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12. plural NETGEAR The device contains an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBW30 prior to 2.6.2.2, RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, RBK753 prior to 3.2.17.12, RBK753S prior to 3.2.17.12, RBK754 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, and RBS750 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1277", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk753", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk754", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbw30", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.2.2" }, { "model": "rbk853", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk753s", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk854", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk753s", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk853", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbw30", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk854", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk753", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk754", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004580" }, { "db": "NVD", "id": "CVE-2021-29074" } ] }, "cve": "CVE-2021-29074", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "id": "CVE-2021-29074", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.9, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "id": "CVE-2021-29074", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 8.4, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-004580", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-29074", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-29074", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2021-29074", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-202103-1350", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-29074", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29074" }, { "db": "JVNDB", "id": "JVNDB-2021-004580" }, { "db": "CNNVD", "id": "CNNVD-202103-1350" }, { "db": "NVD", "id": "CVE-2021-29074" }, { "db": "NVD", "id": "CVE-2021-29074" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects RBW30 before 2.6.2.2, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12. plural NETGEAR The device contains an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBW30 prior to 2.6.2.2, RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, RBK753 prior to 3.2.17.12, RBK753S prior to 3.2.17.12, RBK754 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, and RBS750 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-29074" }, { "db": "JVNDB", "id": "JVNDB-2021-004580" }, { "db": "VULMON", "id": "CVE-2021-29074" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-29074", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2021-004580", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202103-1350", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-29074", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29074" }, { "db": "JVNDB", "id": "JVNDB-2021-004580" }, { "db": "CNNVD", "id": "CNNVD-202103-1350" }, { "db": "NVD", "id": "CVE-2021-29074" } ] }, "id": "VAR-202103-1277", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.303985029 }, "last_update_date": "2024-11-23T23:11:06.765000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Stack\u00a0Overflow\u00a0on\u00a0Some\u00a0WiFi\u00a0Routers,\u00a0PSV-2020-0467", "trust": 0.8, "url": "https://kb.netgear.com/000063011/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-WiFi-Routers-PSV-2020-0467" }, { "title": "NETGEAR Repair measures for buffer errors and vulnerabilities in many products", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=145889" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004580" }, { "db": "CNNVD", "id": "CNNVD-202103-1350" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004580" }, { "db": "NVD", "id": "CVE-2021-29074" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000063011/security-advisory-for-post-authentication-stack-overflow-on-some-wifi-routers-psv-2020-0467" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29074" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/787.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29074" }, { "db": "JVNDB", "id": "JVNDB-2021-004580" }, { "db": "CNNVD", "id": "CNNVD-202103-1350" }, { "db": "NVD", "id": "CVE-2021-29074" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-29074" }, { "db": "JVNDB", "id": "JVNDB-2021-004580" }, { "db": "CNNVD", "id": "CNNVD-202103-1350" }, { "db": "NVD", "id": "CVE-2021-29074" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-23T00:00:00", "db": "VULMON", "id": "CVE-2021-29074" }, { "date": "2021-11-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-004580" }, { "date": "2021-03-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1350" }, { "date": "2021-03-23T07:15:13.797000", "db": "NVD", "id": "CVE-2021-29074" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-24T00:00:00", "db": "VULMON", "id": "CVE-2021-29074" }, { "date": "2021-11-25T03:10:00", "db": "JVNDB", "id": "JVNDB-2021-004580" }, { "date": "2021-03-31T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1350" }, { "date": "2024-11-21T06:00:39.400000", "db": "NVD", "id": "CVE-2021-29074" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1350" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Out-of-bounds write vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004580" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1350" } ], "trust": 0.6 } }
var-202006-0930
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBK842 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, and RBS750 before 3.2.15.25. plural NETGEAR A device contains an injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR.
Injection vulnerabilities exist in many NETGEAR products. The vulnerability stems from the fact that the network system or product lacks the correct verification of the user input data during the operation process of the user inputting the construction command, data structure or record, and the special elements are not filtered or correctly filtered, resulting in the analysis or analysis of the system or product. The explanation is wrong. No detailed vulnerability details are currently provided
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0930", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk752", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44778" }, { "db": "JVNDB", "id": "JVNDB-2020-006744" }, { "db": "NVD", "id": "CVE-2020-14433" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:netgear:rbk752_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk753_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk753s_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk842_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk852_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk853_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr750_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr840_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr850_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs750_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs840_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs850_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006744" } ] }, "cve": "CVE-2020-14433", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "id": "CVE-2020-14433", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.0, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2020-006744", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "id": "CNVD-2021-44778", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "id": "CVE-2020-14433", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "id": "CVE-2020-14433", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-006744", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2020-14433", "trust": 1.0, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2020-14433", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "JVNDB-2020-006744", "trust": 0.8, "value": "Medium" }, { "author": "CNVD", "id": "CNVD-2021-44778", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202006-1248", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44778" }, { "db": "JVNDB", "id": "JVNDB-2020-006744" }, { "db": "CNNVD", "id": "CNNVD-202006-1248" }, { "db": "NVD", "id": "CVE-2020-14433" }, { "db": "NVD", "id": "CVE-2020-14433" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBK842 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, and RBS750 before 3.2.15.25. plural NETGEAR A device contains an injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. \n\r\n\r\nInjection vulnerabilities exist in many NETGEAR products. The vulnerability stems from the fact that the network system or product lacks the correct verification of the user input data during the operation process of the user inputting the construction command, data structure or record, and the special elements are not filtered or correctly filtered, resulting in the analysis or analysis of the system or product. The explanation is wrong. No detailed vulnerability details are currently provided", "sources": [ { "db": "NVD", "id": "CVE-2020-14433" }, { "db": "JVNDB", "id": "JVNDB-2020-006744" }, { "db": "CNVD", "id": "CNVD-2021-44778" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-14433", "trust": 3.0 }, { "db": "JVNDB", "id": "JVNDB-2020-006744", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-44778", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202006-1248", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44778" }, { "db": "JVNDB", "id": "JVNDB-2020-006744" }, { "db": "CNNVD", "id": "CNNVD-202006-1248" }, { "db": "NVD", "id": "CVE-2020-14433" } ] }, "id": "VAR-202006-0930", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-44778" } ], "trust": 1.0097272085714286 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44778" } ] }, "last_update_date": "2024-11-23T21:59:12.224000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Post-Authentication Command Injection on Some WiFi Systems, PSV-2020-0035", "trust": 0.8, "url": "https://kb.netgear.com/000061932/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0035" }, { "title": "Patch for Command injection vulnerabilities in multiple NETGEAR products (CNVD-2021-44778)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/275096" }, { "title": "Multiple NETGEAR Product Command Injection Vulnerability Fixes", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=121996" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44778" }, { "db": "JVNDB", "id": "JVNDB-2020-006744" }, { "db": "CNNVD", "id": "CNNVD-202006-1248" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "CWE-74", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006744" }, { "db": "NVD", "id": "CVE-2020-14433" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14433" }, { "trust": 1.6, "url": "https://kb.netgear.com/000061932/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0035" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14433" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44778" }, { "db": "JVNDB", "id": "JVNDB-2020-006744" }, { "db": "CNNVD", "id": "CNNVD-202006-1248" }, { "db": "NVD", "id": "CVE-2020-14433" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-44778" }, { "db": "JVNDB", "id": "JVNDB-2020-006744" }, { "db": "CNNVD", "id": "CNNVD-202006-1248" }, { "db": "NVD", "id": "CVE-2020-14433" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44778" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006744" }, { "date": "2020-06-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1248" }, { "date": "2020-06-18T17:15:12.453000", "db": "NVD", "id": "CVE-2020-14433" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44778" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006744" }, { "date": "2020-06-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1248" }, { "date": "2024-11-21T05:03:15.677000", "db": "NVD", "id": "CVE-2020-14433" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1248" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR Injection vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006744" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1248" } ], "trust": 0.6 } }
var-202103-1267
Vulnerability from variot
Certain NETGEAR devices are affected by disclosure of sensitive information. This affects RBW30 before 2.6.1.4, RBS40V before 2.6.1.4, RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBK754 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBK854 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR The device contains a vulnerability related to information leakage.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBW30 prior to 2.6.1.4, RBS40V prior to 2.6.1.4, RBK752 prior to 3.2.15.25, RBK753 prior to 3.2.15.25, RBK753S prior to 3.2.15.25, RBK754 prior to 3.2.15.25, RBR750 prior to 3.2.15.25, RBS750 prior to 3.2.15.25, RBK852 prior to 3.2.15.25, RBK853 prior to 3.2.15.25, RBK854 prior to 3.2.15.25, RBR850 prior to 3.2.15.25, and RBS850 prior to 3.2.15.25
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1267", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbw30", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.4" }, { "model": "rbs40v", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.4" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk754", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk854", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk753s", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk853", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbw30", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk753", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs40v", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk754", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004587" }, { "db": "NVD", "id": "CVE-2021-29082" } ] }, "cve": "CVE-2021-29082", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CVE-2021-29082", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "LOW", "trust": 1.9, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "LOW", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2021-29082", "impactScore": 5.3, "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:L/A:L", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2021-29082", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "Low", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-29082", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:L/A:L", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-29082", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-29082", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2021-29082", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-202103-1341", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-29082", "trust": 0.1, "value": "LOW" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29082" }, { "db": "JVNDB", "id": "JVNDB-2021-004587" }, { "db": "CNNVD", "id": "CNNVD-202103-1341" }, { "db": "NVD", "id": "CVE-2021-29082" }, { "db": "NVD", "id": "CVE-2021-29082" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects RBW30 before 2.6.1.4, RBS40V before 2.6.1.4, RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBK754 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBK854 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR The device contains a vulnerability related to information leakage.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBW30 prior to 2.6.1.4, RBS40V prior to 2.6.1.4, RBK752 prior to 3.2.15.25, RBK753 prior to 3.2.15.25, RBK753S prior to 3.2.15.25, RBK754 prior to 3.2.15.25, RBR750 prior to 3.2.15.25, RBS750 prior to 3.2.15.25, RBK852 prior to 3.2.15.25, RBK853 prior to 3.2.15.25, RBK854 prior to 3.2.15.25, RBR850 prior to 3.2.15.25, and RBS850 prior to 3.2.15.25", "sources": [ { "db": "NVD", "id": "CVE-2021-29082" }, { "db": "JVNDB", "id": "JVNDB-2021-004587" }, { "db": "VULMON", "id": "CVE-2021-29082" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-29082", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2021-004587", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202103-1341", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-29082", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29082" }, { "db": "JVNDB", "id": "JVNDB-2021-004587" }, { "db": "CNNVD", "id": "CNNVD-202103-1341" }, { "db": "NVD", "id": "CVE-2021-29082" } ] }, "id": "VAR-202103-1267", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.303985029 }, "last_update_date": "2024-11-23T22:40:42.092000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Sensitive\u00a0Information\u00a0Disclosure\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0037", "trust": 0.8, "url": "https://kb.netgear.com/000063005/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-WiFi-Systems-PSV-2020-0037" }, { "title": "NETGEAR Repair measures for information disclosure vulnerabilities of various products", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=145157" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004587" }, { "db": "CNNVD", "id": "CNNVD-202103-1341" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "information leak (CWE-200) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004587" }, { "db": "NVD", "id": "CVE-2021-29082" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000063005/security-advisory-for-sensitive-information-disclosure-on-some-wifi-systems-psv-2020-0037" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29082" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/200.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29082" }, { "db": "JVNDB", "id": "JVNDB-2021-004587" }, { "db": "CNNVD", "id": "CNNVD-202103-1341" }, { "db": "NVD", "id": "CVE-2021-29082" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-29082" }, { "db": "JVNDB", "id": "JVNDB-2021-004587" }, { "db": "CNNVD", "id": "CNNVD-202103-1341" }, { "db": "NVD", "id": "CVE-2021-29082" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-23T00:00:00", "db": "VULMON", "id": "CVE-2021-29082" }, { "date": "2021-11-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-004587" }, { "date": "2021-03-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1341" }, { "date": "2021-03-23T07:15:14.390000", "db": "NVD", "id": "CVE-2021-29082" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-24T00:00:00", "db": "VULMON", "id": "CVE-2021-29082" }, { "date": "2021-11-25T03:10:00", "db": "JVNDB", "id": "JVNDB-2021-004587" }, { "date": "2021-08-16T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1341" }, { "date": "2024-11-21T06:00:40.660000", "db": "NVD", "id": "CVE-2021-29082" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1341" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Information leakage vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004587" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "information disclosure", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1341" } ], "trust": 0.6 } }
var-202006-0901
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR On the device OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. Attackers can use this vulnerability to execute arbitrary shell commands with the help of specially crafted requests
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0901", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk752", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44787" }, { "db": "JVNDB", "id": "JVNDB-2020-006683" }, { "db": "NVD", "id": "CVE-2020-14442" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:netgear:rbk752_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk753_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk753s_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk842_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk852_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk853_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr750_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr840_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs750_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs840_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006683" } ] }, "cve": "CVE-2020-14442", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CVE-2020-14442", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.0, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2020-006683", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CNVD-2021-44787", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2020-14442", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2020-14442", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-006683", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2020-14442", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-14442", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "JVNDB-2020-006683", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-44787", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202006-1266", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44787" }, { "db": "JVNDB", "id": "JVNDB-2020-006683" }, { "db": "CNNVD", "id": "CNNVD-202006-1266" }, { "db": "NVD", "id": "CVE-2020-14442" }, { "db": "NVD", "id": "CVE-2020-14442" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR On the device OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. Attackers can use this vulnerability to execute arbitrary shell commands with the help of specially crafted requests", "sources": [ { "db": "NVD", "id": "CVE-2020-14442" }, { "db": "JVNDB", "id": "JVNDB-2020-006683" }, { "db": "CNVD", "id": "CNVD-2021-44787" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-14442", "trust": 3.0 }, { "db": "JVNDB", "id": "JVNDB-2020-006683", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-44787", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202006-1266", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44787" }, { "db": "JVNDB", "id": "JVNDB-2020-006683" }, { "db": "CNNVD", "id": "CNNVD-202006-1266" }, { "db": "NVD", "id": "CVE-2020-14442" } ] }, "id": "VAR-202006-0901", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-44787" } ], "trust": 1.0097272085714286 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44787" } ] }, "last_update_date": "2024-11-23T21:35:44.296000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Pre-Authentification Command Injection on Some WiFi Systems, PSV-2020-0103", "trust": 0.8, "url": "https://kb.netgear.com/000061947/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0103" }, { "title": "Patch for Operating system command injection vulnerabilities in multiple NETGEAR products (CNVD-2021-44787)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/275066" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44787" }, { "db": "JVNDB", "id": "JVNDB-2020-006683" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "CWE-78", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006683" }, { "db": "NVD", "id": "CVE-2020-14442" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14442" }, { "trust": 1.6, "url": "https://kb.netgear.com/000061947/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0103" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14442" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44787" }, { "db": "JVNDB", "id": "JVNDB-2020-006683" }, { "db": "CNNVD", "id": "CNNVD-202006-1266" }, { "db": "NVD", "id": "CVE-2020-14442" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-44787" }, { "db": "JVNDB", "id": "JVNDB-2020-006683" }, { "db": "CNNVD", "id": "CNNVD-202006-1266" }, { "db": "NVD", "id": "CVE-2020-14442" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44787" }, { "date": "2020-07-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006683" }, { "date": "2020-06-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1266" }, { "date": "2020-06-18T17:15:13.327000", "db": "NVD", "id": "CVE-2020-14442" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44787" }, { "date": "2020-07-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006683" }, { "date": "2020-07-02T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1266" }, { "date": "2024-11-21T05:03:17.260000", "db": "NVD", "id": "CVE-2020-14442" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1266" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR On the device OS Command injection vulnerabilities", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006683" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "operating system commend injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1266" } ], "trust": 0.6 } }
var-202103-1266
Vulnerability from variot
Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects RBW30 before 2.6.2.2, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12. plural NETGEAR The device contains an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBW30 prior to 2.6.2.2, RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, RBK753 prior to 3.2.17.12, RBK753S prior to 3.2.17.12, RBK754 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, and RBS750 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1266", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk753", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk754", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbw30", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.2.2" }, { "model": "rbk853", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk753s", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk854", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk753s", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk853", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbw30", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk854", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk753", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk754", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004586" }, { "db": "NVD", "id": "CVE-2021-29081" } ] }, "cve": "CVE-2021-29081", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CVE-2021-29081", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.9, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "id": "CVE-2021-29081", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 8.4, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-004586", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-29081", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-29081", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2021-29081", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-202103-1342", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-29081", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29081" }, { "db": "JVNDB", "id": "JVNDB-2021-004586" }, { "db": "CNNVD", "id": "CNNVD-202103-1342" }, { "db": "NVD", "id": "CVE-2021-29081" }, { "db": "NVD", "id": "CVE-2021-29081" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects RBW30 before 2.6.2.2, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12. plural NETGEAR The device contains an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBW30 prior to 2.6.2.2, RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, RBK753 prior to 3.2.17.12, RBK753S prior to 3.2.17.12, RBK754 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, and RBS750 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-29081" }, { "db": "JVNDB", "id": "JVNDB-2021-004586" }, { "db": "VULMON", "id": "CVE-2021-29081" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-29081", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2021-004586", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202103-1342", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-29081", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29081" }, { "db": "JVNDB", "id": "JVNDB-2021-004586" }, { "db": "CNNVD", "id": "CNNVD-202103-1342" }, { "db": "NVD", "id": "CVE-2021-29081" } ] }, "id": "VAR-202103-1266", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.303985029 }, "last_update_date": "2024-11-23T22:29:17.437000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Stack\u00a0Overflow\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0465", "trust": 0.8, "url": "https://kb.netgear.com/000063012/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-WiFi-Systems-PSV-2020-0465" }, { "title": "NETGEAR Repair measures for buffer errors and vulnerabilities in many products", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=145158" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004586" }, { "db": "CNNVD", "id": "CNNVD-202103-1342" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004586" }, { "db": "NVD", "id": "CVE-2021-29081" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000063012/security-advisory-for-pre-authentication-stack-overflow-on-some-wifi-systems-psv-2020-0465" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29081" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/787.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29081" }, { "db": "JVNDB", "id": "JVNDB-2021-004586" }, { "db": "CNNVD", "id": "CNNVD-202103-1342" }, { "db": "NVD", "id": "CVE-2021-29081" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-29081" }, { "db": "JVNDB", "id": "JVNDB-2021-004586" }, { "db": "CNNVD", "id": "CNNVD-202103-1342" }, { "db": "NVD", "id": "CVE-2021-29081" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-23T00:00:00", "db": "VULMON", "id": "CVE-2021-29081" }, { "date": "2021-11-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-004586" }, { "date": "2021-03-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1342" }, { "date": "2021-03-23T07:15:14.310000", "db": "NVD", "id": "CVE-2021-29081" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-24T00:00:00", "db": "VULMON", "id": "CVE-2021-29081" }, { "date": "2021-11-25T03:10:00", "db": "JVNDB", "id": "JVNDB-2021-004586" }, { "date": "2021-08-16T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1342" }, { "date": "2024-11-21T06:00:40.503000", "db": "NVD", "id": "CVE-2021-29081" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1342" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Out-of-bounds write vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004586" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1342" } ], "trust": 0.6 } }
var-202006-0933
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, and RBS840 before 3.2.15.25. plural NETGEAR A device contains an injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR.
Injection vulnerabilities exist in many NETGEAR products. Attackers can use this vulnerability to execute arbitrary Shell commands on the system by sending a specially crafted request
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0933", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk752", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44781" }, { "db": "JVNDB", "id": "JVNDB-2020-006741" }, { "db": "NVD", "id": "CVE-2020-14436" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:netgear:rbk752_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk753_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk753s_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk842_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk852_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbk853_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr750_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbr850_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs750_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:rbs850_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006741" } ] }, "cve": "CVE-2020-14436", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CVE-2020-14436", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.0, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2020-006741", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CNVD-2021-44781", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2020-14436", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2020-14436", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-006741", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2020-14436", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-14436", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "JVNDB-2020-006741", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-44781", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202006-1252", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44781" }, { "db": "JVNDB", "id": "JVNDB-2020-006741" }, { "db": "CNNVD", "id": "CNNVD-202006-1252" }, { "db": "NVD", "id": "CVE-2020-14436" }, { "db": "NVD", "id": "CVE-2020-14436" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, and RBS840 before 3.2.15.25. plural NETGEAR A device contains an injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. \n\r\n\r\nInjection vulnerabilities exist in many NETGEAR products. Attackers can use this vulnerability to execute arbitrary Shell commands on the system by sending a specially crafted request", "sources": [ { "db": "NVD", "id": "CVE-2020-14436" }, { "db": "JVNDB", "id": "JVNDB-2020-006741" }, { "db": "CNVD", "id": "CNVD-2021-44781" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-14436", "trust": 3.0 }, { "db": "JVNDB", "id": "JVNDB-2020-006741", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-44781", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202006-1252", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44781" }, { "db": "JVNDB", "id": "JVNDB-2020-006741" }, { "db": "CNNVD", "id": "CNNVD-202006-1252" }, { "db": "NVD", "id": "CVE-2020-14436" } ] }, "id": "VAR-202006-0933", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-44781" } ], "trust": 1.0097272085714286 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44781" } ] }, "last_update_date": "2024-11-23T22:29:35.912000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Pre-Authentication Command Injection on Some WiFi Systems, PSV-2020-0039", "trust": 0.8, "url": "https://kb.netgear.com/000061933/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0039" }, { "title": "Patch for Command injection vulnerabilities in multiple NETGEAR products (CNVD-2021-44781)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/275081" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44781" }, { "db": "JVNDB", "id": "JVNDB-2020-006741" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "CWE-74", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006741" }, { "db": "NVD", "id": "CVE-2020-14436" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14436" }, { "trust": 1.6, "url": "https://kb.netgear.com/000061933/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0039" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14436" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44781" }, { "db": "JVNDB", "id": "JVNDB-2020-006741" }, { "db": "CNNVD", "id": "CNNVD-202006-1252" }, { "db": "NVD", "id": "CVE-2020-14436" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-44781" }, { "db": "JVNDB", "id": "JVNDB-2020-006741" }, { "db": "CNNVD", "id": "CNNVD-202006-1252" }, { "db": "NVD", "id": "CVE-2020-14436" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44781" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006741" }, { "date": "2020-06-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1252" }, { "date": "2020-06-18T17:15:12.750000", "db": "NVD", "id": "CVE-2020-14436" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44781" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006741" }, { "date": "2020-07-02T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1252" }, { "date": "2024-11-21T05:03:16.207000", "db": "NVD", "id": "CVE-2020-14436" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1252" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR Injection vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006741" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1252" } ], "trust": 0.6 } }
cve-2020-14439
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.372Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061942/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0064" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-18T16:38:47", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061942/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0064" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-14439", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061942/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0064", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061942/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0064" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-14439", "datePublished": "2020-06-18T16:38:47", "dateReserved": "2020-06-18T00:00:00", "dateUpdated": "2024-08-04T12:46:34.372Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-29068
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T21:55:12.644Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063021/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0155" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects R6700v3 before 1.0.4.98, R6400v2 before 1.0.4.98, R7000 before 1.0.11.106, R6900P before 1.3.2.124, R7000P before 1.3.2.124, R7900 before 1.0.4.26, R7850 before 1.0.5.60, R8000 before 1.0.4.58, RS400 before 1.5.0.48, R6400 before 1.0.1.62, R6700 before 1.0.2.16, R6900 before 1.0.2.16, MK60 before 1.0.5.102, MR60 before 1.0.5.102, MS60 before 1.0.5.102, CBR40 before 2.5.0.10, R8000P before 1.4.1.62, R7960P before 1.4.1.62, R7900P before 1.4.1.62, RAX15 before 1.0.1.64, RAX20 before 1.0.1.64, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RAX200 before 1.0.2.102, RAX45 before 1.0.2.64, RAX50 before 1.0.2.64, EX7500 before 1.0.0.68, EAX80 before 1.0.1.62, EAX20 before 1.0.0.36, RBK752 before 3.2.16.6, RBK753 before 3.2.16.6, RBK753S before 3.2.16.6, RBK754 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBK853 before 3.2.16.6, RBK854 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RBR840 before 3.2.16.6, RBS840 before 3.2.16.6, R6120 before 1.0.0.70, R6220 before 1.1.0.100, R6230 before 1.1.0.100, R6260 before 1.1.0.76, R6850 before 1.1.0.76, R6350 before 1.1.0.76, R6330 before 1.1.0.76, D7800 before 1.0.1.58, RBK50 before 2.6.1.40, RBR50 before 2.6.1.40, RBS50 before 2.6.1.40, RBK40 before 2.6.1.36, RBR40 before 2.6.1.36, RBS40 before 2.6.1.38, RBK23 before 2.6.1.36, RBR20 before 2.6.1.38, RBS20 before 2.6.1.38, RBK12 before 2.6.1.44, RBK13 before 2.6.1.44, RBK14 before 2.6.1.44, RBK15 before 2.6.1.44, RBR10 before 2.6.1.44, RBS10 before 2.6.1.44, R6800 before 1.2.0.72, R6900v2 before 1.2.0.72, R6700v2 before 1.2.0.72, R7200 before 1.2.0.72, R7350 before 1.2.0.72, R7400 before 1.2.0.72, R7450 before 1.2.0.72, AC2100 before 1.2.0.72, AC2400 before 1.2.0.72, AC2600 before 1.2.0.72, R7800 before 1.0.2.74, R8900 before 1.0.5.24, R9000 before 1.0.5.24, RAX120 before 1.0.1.136, XR450 before 2.3.2.66, XR500 before 2.3.2.66, XR700 before 1.0.1.34, and XR300 before 1.0.3.50." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.9, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:N/A:H/C:H/I:H/PR:L/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-23T07:04:52", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063021/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0155" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-29068", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects R6700v3 before 1.0.4.98, R6400v2 before 1.0.4.98, R7000 before 1.0.11.106, R6900P before 1.3.2.124, R7000P before 1.3.2.124, R7900 before 1.0.4.26, R7850 before 1.0.5.60, R8000 before 1.0.4.58, RS400 before 1.5.0.48, R6400 before 1.0.1.62, R6700 before 1.0.2.16, R6900 before 1.0.2.16, MK60 before 1.0.5.102, MR60 before 1.0.5.102, MS60 before 1.0.5.102, CBR40 before 2.5.0.10, R8000P before 1.4.1.62, R7960P before 1.4.1.62, R7900P before 1.4.1.62, RAX15 before 1.0.1.64, RAX20 before 1.0.1.64, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RAX200 before 1.0.2.102, RAX45 before 1.0.2.64, RAX50 before 1.0.2.64, EX7500 before 1.0.0.68, EAX80 before 1.0.1.62, EAX20 before 1.0.0.36, RBK752 before 3.2.16.6, RBK753 before 3.2.16.6, RBK753S before 3.2.16.6, RBK754 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBK853 before 3.2.16.6, RBK854 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RBR840 before 3.2.16.6, RBS840 before 3.2.16.6, R6120 before 1.0.0.70, R6220 before 1.1.0.100, R6230 before 1.1.0.100, R6260 before 1.1.0.76, R6850 before 1.1.0.76, R6350 before 1.1.0.76, R6330 before 1.1.0.76, D7800 before 1.0.1.58, RBK50 before 2.6.1.40, RBR50 before 2.6.1.40, RBS50 before 2.6.1.40, RBK40 before 2.6.1.36, RBR40 before 2.6.1.36, RBS40 before 2.6.1.38, RBK23 before 2.6.1.36, RBR20 before 2.6.1.38, RBS20 before 2.6.1.38, RBK12 before 2.6.1.44, RBK13 before 2.6.1.44, RBK14 before 2.6.1.44, RBK15 before 2.6.1.44, RBR10 before 2.6.1.44, RBS10 before 2.6.1.44, R6800 before 1.2.0.72, R6900v2 before 1.2.0.72, R6700v2 before 1.2.0.72, R7200 before 1.2.0.72, R7350 before 1.2.0.72, R7400 before 1.2.0.72, R7450 before 1.2.0.72, AC2100 before 1.2.0.72, AC2400 before 1.2.0.72, AC2600 before 1.2.0.72, R7800 before 1.0.2.74, R8900 before 1.0.5.24, R9000 before 1.0.5.24, RAX120 before 1.0.1.136, XR450 before 2.3.2.66, XR500 before 2.3.2.66, XR700 before 1.0.1.34, and XR300 before 1.0.3.50." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:N/A:H/C:H/I:H/PR:L/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063021/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0155", "refsource": "MISC", "url": "https://kb.netgear.com/000063021/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0155" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-29068", "datePublished": "2021-03-23T06:57:00", "dateReserved": "2021-03-23T00:00:00", "dateUpdated": "2024-08-03T21:55:12.644Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-29071
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T21:55:12.613Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063008/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0476" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBR752 before 3.2.17.12, RBR753 before 3.2.17.12, RBR753S before 3.2.17.12, RBR754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-23T06:59:58", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063008/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0476" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-29071", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBR752 before 3.2.17.12, RBR753 before 3.2.17.12, RBR753S before 3.2.17.12, RBR754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063008/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0476", "refsource": "MISC", "url": "https://kb.netgear.com/000063008/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0476" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-29071", "datePublished": "2021-03-23T06:59:58", "dateReserved": "2021-03-23T00:00:00", "dateUpdated": "2024-08-03T21:55:12.613Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-29076
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T21:55:12.657Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063015/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0485" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-23T06:59:23", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063015/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0485" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-29076", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063015/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0485", "refsource": "MISC", "url": "https://kb.netgear.com/000063015/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0485" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-29076", "datePublished": "2021-03-23T06:59:23", "dateReserved": "2021-03-23T00:00:00", "dateUpdated": "2024-08-03T21:55:12.657Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-14441
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.611Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061946/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0071" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-18T16:39:36", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061946/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0071" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-14441", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061946/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0071", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061946/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0071" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-14441", "datePublished": "2020-06-18T16:39:36", "dateReserved": "2020-06-18T00:00:00", "dateUpdated": "2024-08-04T12:46:34.611Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-14430
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.455Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061939/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0051" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-18T16:26:18", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061939/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0051" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-14430", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061939/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0051", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061939/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0051" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-14430", "datePublished": "2020-06-18T16:26:18", "dateReserved": "2020-06-18T00:00:00", "dateUpdated": "2024-08-04T12:46:34.455Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-29081
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T21:55:12.508Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063012/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-WiFi-Systems-PSV-2020-0465" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects RBW30 before 2.6.2.2, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-23T06:58:41", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063012/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-WiFi-Systems-PSV-2020-0465" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-29081", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects RBW30 before 2.6.2.2, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063012/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-WiFi-Systems-PSV-2020-0465", "refsource": "MISC", "url": "https://kb.netgear.com/000063012/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-WiFi-Systems-PSV-2020-0465" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-29081", "datePublished": "2021-03-23T06:58:41", "dateReserved": "2021-03-23T00:00:00", "dateUpdated": "2024-08-03T21:55:12.508Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-29075
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T21:55:12.479Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063010/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-WiFi-Systems-PSV-2020-0466" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects RBW30 before 2.6.2.2, RBK852 before 3.2.17.12, RBK852 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-23T06:59:31", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063010/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-WiFi-Systems-PSV-2020-0466" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-29075", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects RBW30 before 2.6.2.2, RBK852 before 3.2.17.12, RBK852 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063010/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-WiFi-Systems-PSV-2020-0466", "refsource": "MISC", "url": "https://kb.netgear.com/000063010/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-WiFi-Systems-PSV-2020-0466" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-29075", "datePublished": "2021-03-23T06:59:31", "dateReserved": "2021-03-23T00:00:00", "dateUpdated": "2024-08-03T21:55:12.479Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-29072
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T21:55:12.619Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063018/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0493" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-23T06:59:51", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063018/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0493" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-29072", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063018/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0493", "refsource": "MISC", "url": "https://kb.netgear.com/000063018/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0493" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-29072", "datePublished": "2021-03-23T06:59:51", "dateReserved": "2021-03-23T00:00:00", "dateUpdated": "2024-08-03T21:55:12.619Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-14427
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.311Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061935/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0042" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-18T16:21:05", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061935/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0042" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-14427", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061935/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0042", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061935/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0042" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-14427", "datePublished": "2020-06-18T16:21:05", "dateReserved": "2020-06-18T00:00:00", "dateUpdated": "2024-08-04T12:46:34.311Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-29067
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T21:55:12.518Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063017/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0492" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects RBW30 before 2.6.2.2, RBS40V before 2.6.2.4, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-23T07:00:27", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063017/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0492" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-29067", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects RBW30 before 2.6.2.2, RBS40V before 2.6.2.4, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063017/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0492", "refsource": "MISC", "url": "https://kb.netgear.com/000063017/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0492" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-29067", "datePublished": "2021-03-23T07:00:28", "dateReserved": "2021-03-23T00:00:00", "dateUpdated": "2024-08-03T21:55:12.518Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-14433
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.580Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061932/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0035" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBK842 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, and RBS750 before 3.2.15.25." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-18T16:33:53", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061932/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0035" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-14433", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBK842 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, and RBS750 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061932/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0035", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061932/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0035" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-14433", "datePublished": "2020-06-18T16:33:53", "dateReserved": "2020-06-18T00:00:00", "dateUpdated": "2024-08-04T12:46:34.580Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-14428
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.682Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061936/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0044" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-18T16:21:45", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061936/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0044" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-14428", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061936/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0044", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061936/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0044" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-14428", "datePublished": "2020-06-18T16:21:45", "dateReserved": "2020-06-18T00:00:00", "dateUpdated": "2024-08-04T12:46:34.682Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-14437
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.680Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061940/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0054" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-18T16:37:40", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061940/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0054" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-14437", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061940/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0054", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061940/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0054" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-14437", "datePublished": "2020-06-18T16:37:40", "dateReserved": "2020-06-18T00:00:00", "dateUpdated": "2024-08-04T12:46:34.680Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-14432
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.433Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061937/Security-Advisory-for-Cross-Site-Request-Forgery-on-Some-WiFi-Systems-PSV-2020-0049" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by CSRF. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-18T16:33:29", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061937/Security-Advisory-for-Cross-Site-Request-Forgery-on-Some-WiFi-Systems-PSV-2020-0049" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-14432", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by CSRF. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061937/Security-Advisory-for-Cross-Site-Request-Forgery-on-Some-WiFi-Systems-PSV-2020-0049", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061937/Security-Advisory-for-Cross-Site-Request-Forgery-on-Some-WiFi-Systems-PSV-2020-0049" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-14432", "datePublished": "2020-06-18T16:33:29", "dateReserved": "2020-06-18T00:00:00", "dateUpdated": "2024-08-04T12:46:34.433Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-14442
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.605Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061947/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0103" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-18T16:40:19", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061947/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0103" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-14442", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061947/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0103", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061947/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0103" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-14442", "datePublished": "2020-06-18T16:40:19", "dateReserved": "2020-06-18T00:00:00", "dateUpdated": "2024-08-04T12:46:34.605Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-14436
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.600Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061933/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0039" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, and RBS840 before 3.2.15.25." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-18T16:35:43", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061933/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0039" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-14436", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, and RBS840 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061933/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0039", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061933/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0039" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-14436", "datePublished": "2020-06-18T16:35:43", "dateReserved": "2020-06-18T00:00:00", "dateUpdated": "2024-08-04T12:46:34.600Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-29079
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T21:55:12.662Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063020/Security-Advisory-for-Pre-Authentication-Command-Injection-Some-WiFi-Routers-PSV-2020-0470" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-23T06:59:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063020/Security-Advisory-for-Pre-Authentication-Command-Injection-Some-WiFi-Routers-PSV-2020-0470" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-29079", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063020/Security-Advisory-for-Pre-Authentication-Command-Injection-Some-WiFi-Routers-PSV-2020-0470", "refsource": "MISC", "url": "https://kb.netgear.com/000063020/Security-Advisory-for-Pre-Authentication-Command-Injection-Some-WiFi-Routers-PSV-2020-0470" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-29079", "datePublished": "2021-03-23T06:59:01", "dateReserved": "2021-03-23T00:00:00", "dateUpdated": "2024-08-03T21:55:12.662Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-14434
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.525Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061934/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0040" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, and RBS840 before 3.2.15.25." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-18T16:34:38", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061934/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0040" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-14434", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, and RBS840 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061934/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0040", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061934/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0040" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-14434", "datePublished": "2020-06-18T16:34:38", "dateReserved": "2020-06-18T00:00:00", "dateUpdated": "2024-08-04T12:46:34.525Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-29080
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T21:55:12.513Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063007/Security-Advisory-for-Pre-authentication-Password-Reset-on-Some-Routers-and-WiFi-Systems-PSV-2019-0150" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by password reset by an unauthenticated attacker. This affects RBK852 before 3.2.10.11, RBK853 before 3.2.10.11, RBR854 before 3.2.10.11, RBR850 before 3.2.10.11, RBS850 before 3.2.10.11, CBR40 before 2.5.0.10, R7000 before 1.0.11.116, R6900P before 1.3.2.126, R7900 before 1.0.4.38, R7960P before 1.4.1.66, R8000 before 1.0.4.66, R7900P before 1.4.1.66, R8000P before 1.4.1.66, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, and R7000P before 1.3.2.126." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:N/C:H/I:H/PR:N/S:U/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-23T06:58:53", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063007/Security-Advisory-for-Pre-authentication-Password-Reset-on-Some-Routers-and-WiFi-Systems-PSV-2019-0150" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-29080", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by password reset by an unauthenticated attacker. This affects RBK852 before 3.2.10.11, RBK853 before 3.2.10.11, RBR854 before 3.2.10.11, RBR850 before 3.2.10.11, RBS850 before 3.2.10.11, CBR40 before 2.5.0.10, R7000 before 1.0.11.116, R6900P before 1.3.2.126, R7900 before 1.0.4.38, R7960P before 1.4.1.66, R8000 before 1.0.4.66, R7900P before 1.4.1.66, R8000P before 1.4.1.66, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, and R7000P before 1.3.2.126." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "NONE", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:N/C:H/I:H/PR:N/S:U/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063007/Security-Advisory-for-Pre-authentication-Password-Reset-on-Some-Routers-and-WiFi-Systems-PSV-2019-0150", "refsource": "MISC", "url": "https://kb.netgear.com/000063007/Security-Advisory-for-Pre-authentication-Password-Reset-on-Some-Routers-and-WiFi-Systems-PSV-2019-0150" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-29080", "datePublished": "2021-03-23T06:58:53", "dateReserved": "2021-03-23T00:00:00", "dateUpdated": "2024-08-03T21:55:12.513Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-29078
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T21:55:12.616Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063009/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0511" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-23T06:59:09", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063009/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0511" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-29078", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063009/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0511", "refsource": "MISC", "url": "https://kb.netgear.com/000063009/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0511" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-29078", "datePublished": "2021-03-23T06:59:09", "dateReserved": "2021-03-23T00:00:00", "dateUpdated": "2024-08-03T21:55:12.616Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-14431
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.563Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061944/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0068" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-18T16:26:41", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061944/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0068" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-14431", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061944/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0068", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061944/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0068" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-14431", "datePublished": "2020-06-18T16:26:41", "dateReserved": "2020-06-18T00:00:00", "dateUpdated": "2024-08-04T12:46:34.563Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-14426
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.252Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061931/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-Wifi-Systems-PSV-2020-0033" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBK853 before 3.2.10.11, RBR850 before 3.2.10.11, RBS850 before 3.2.10.11, RBK842 before 3.2.10.11, RBR840 before 3.2.10.11, and RBS840 before 3.2.10.11." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-18T16:20:03", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061931/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-Wifi-Systems-PSV-2020-0033" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-14426", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBK853 before 3.2.10.11, RBR850 before 3.2.10.11, RBS850 before 3.2.10.11, RBK842 before 3.2.10.11, RBR840 before 3.2.10.11, and RBS840 before 3.2.10.11." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061931/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-Wifi-Systems-PSV-2020-0033", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061931/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-Wifi-Systems-PSV-2020-0033" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-14426", "datePublished": "2020-06-18T16:20:03", "dateReserved": "2020-06-18T00:00:00", "dateUpdated": "2024-08-04T12:46:34.252Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-29074
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T21:55:12.649Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063011/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-WiFi-Routers-PSV-2020-0467" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects RBW30 before 2.6.2.2, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-23T06:59:37", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063011/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-WiFi-Routers-PSV-2020-0467" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-29074", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects RBW30 before 2.6.2.2, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063011/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-WiFi-Routers-PSV-2020-0467", "refsource": "MISC", "url": "https://kb.netgear.com/000063011/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-WiFi-Routers-PSV-2020-0467" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-29074", "datePublished": "2021-03-23T06:59:37", "dateReserved": "2021-03-23T00:00:00", "dateUpdated": "2024-08-03T21:55:12.649Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-14438
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.524Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061941/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0063" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-18T16:38:07", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061941/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0063" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-14438", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061941/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0063", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061941/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0063" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-14438", "datePublished": "2020-06-18T16:38:07", "dateReserved": "2020-06-18T00:00:00", "dateUpdated": "2024-08-04T12:46:34.524Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-14440
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.308Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061943/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0065" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-18T16:39:13", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061943/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0065" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-14440", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061943/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0065", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061943/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0065" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-14440", "datePublished": "2020-06-18T16:39:13", "dateReserved": "2020-06-18T00:00:00", "dateUpdated": "2024-08-04T12:46:34.308Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-29070
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T21:55:12.605Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063019/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Routers-PSV-2020-0530" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-23T07:00:05", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063019/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Routers-PSV-2020-0530" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-29070", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063019/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Routers-PSV-2020-0530", "refsource": "MISC", "url": "https://kb.netgear.com/000063019/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Routers-PSV-2020-0530" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-29070", "datePublished": "2021-03-23T07:00:05", "dateReserved": "2021-03-23T00:00:00", "dateUpdated": "2024-08-03T21:55:12.605Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-29077
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T21:55:12.666Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063016/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0486" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBW30 before 2.6.2.2, RBS40V before 2.6.2.4, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-23T06:59:16", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063016/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0486" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-29077", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBW30 before 2.6.2.2, RBS40V before 2.6.2.4, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063016/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0486", "refsource": "MISC", "url": "https://kb.netgear.com/000063016/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0486" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-29077", "datePublished": "2021-03-23T06:59:16", "dateReserved": "2021-03-23T00:00:00", "dateUpdated": "2024-08-03T21:55:12.666Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-29066
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T21:55:12.497Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063014/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0484" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-23T07:00:35", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063014/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0484" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-29066", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063014/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0484", "refsource": "MISC", "url": "https://kb.netgear.com/000063014/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0484" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-29066", "datePublished": "2021-03-23T07:00:35", "dateReserved": "2021-03-23T00:00:00", "dateUpdated": "2024-08-03T21:55:12.497Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-29082
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T21:55:12.631Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063005/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-WiFi-Systems-PSV-2020-0037" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects RBW30 before 2.6.1.4, RBS40V before 2.6.1.4, RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBK754 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBK854 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-23T06:58:28", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063005/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-WiFi-Systems-PSV-2020-0037" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-29082", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects RBW30 before 2.6.1.4, RBS40V before 2.6.1.4, RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBK754 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBK854 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063005/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-WiFi-Systems-PSV-2020-0037", "refsource": "MISC", "url": "https://kb.netgear.com/000063005/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-WiFi-Systems-PSV-2020-0037" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-29082", "datePublished": "2021-03-23T06:58:28", "dateReserved": "2021-03-23T00:00:00", "dateUpdated": "2024-08-03T21:55:12.631Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-14429
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.531Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061938/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0050" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects MK62 before 1.0.4.92, MK63 before 1.0.4.92, MR60 before 1.0.4.92, MS60 before 1.0.4.92, RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBS750 before 3.2.15.25, RBR750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-18T16:25:30", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061938/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0050" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-14429", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects MK62 before 1.0.4.92, MK63 before 1.0.4.92, MR60 before 1.0.4.92, MS60 before 1.0.4.92, RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBS750 before 3.2.15.25, RBR750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061938/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0050", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061938/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0050" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-14429", "datePublished": "2020-06-18T16:25:30", "dateReserved": "2020-06-18T00:00:00", "dateUpdated": "2024-08-04T12:46:34.531Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }