Vulnerabilites related to mitsubishielectric - q03udvcpu
cve-2019-6535
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
http://www.securityfocus.com/bid/106771 | vdb-entry, x_refsource_BID | |
https://ics-cert.us-cert.gov/advisories/ICSA-19-029-02 | x_refsource_MISC |
Vendor | Product | Version | ||
---|---|---|---|---|
ICS-CERT | Mitsubishi Electric Q03/04/06/13/26UDVCPU: serial number 20081 and prior, Q04/06/13/26UDPVCPU: serial number 20081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 20101 and prior. |
Version: Mitsubishi Electric Q03/04/06/13/26UDVCPU: serial number 20081 and prior, Q04/06/13/26UDPVCPU: serial number 20081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 20101 and prior. |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T20:23:21.974Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "106771", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/106771" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-029-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Mitsubishi Electric Q03/04/06/13/26UDVCPU: serial number 20081 and prior, Q04/06/13/26UDPVCPU: serial number 20081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 20101 and prior.", "vendor": "ICS-CERT", "versions": [ { "status": "affected", "version": "Mitsubishi Electric Q03/04/06/13/26UDVCPU: serial number 20081 and prior, Q04/06/13/26UDPVCPU: serial number 20081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 20101 and prior." } ] } ], "datePublic": "2019-01-29T00:00:00", "descriptions": [ { "lang": "en", "value": "Mitsubishi Electric Q03/04/06/13/26UDVCPU: serial number 20081 and prior, Q04/06/13/26UDPVCPU: serial number 20081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 20101 and prior. A remote attacker can send specific bytes over Port 5007 that will result in an Ethernet stack crash." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "UNCONTROLLED RESOURCE CONSUMPTION (\u0027RESOURCE EXHAUSTION\u0027) CWE-400", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2019-02-06T10:57:02", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "name": "106771", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/106771" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-029-02" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2019-01-29T00:00:00", "ID": "CVE-2019-6535", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Mitsubishi Electric Q03/04/06/13/26UDVCPU: serial number 20081 and prior, Q04/06/13/26UDPVCPU: serial number 20081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 20101 and prior.", "version": { "version_data": [ { "version_value": "Mitsubishi Electric Q03/04/06/13/26UDVCPU: serial number 20081 and prior, Q04/06/13/26UDPVCPU: serial number 20081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 20101 and prior." } ] } } ] }, "vendor_name": "ICS-CERT" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Mitsubishi Electric Q03/04/06/13/26UDVCPU: serial number 20081 and prior, Q04/06/13/26UDPVCPU: serial number 20081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 20101 and prior. A remote attacker can send specific bytes over Port 5007 that will result in an Ethernet stack crash." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "UNCONTROLLED RESOURCE CONSUMPTION (\u0027RESOURCE EXHAUSTION\u0027) CWE-400" } ] } ] }, "references": { "reference_data": [ { "name": "106771", "refsource": "BID", "url": "http://www.securityfocus.com/bid/106771" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-029-02", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-029-02" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2019-6535", "datePublished": "2019-02-05T19:00:00Z", "dateReserved": "2019-01-22T00:00:00", "dateUpdated": "2024-09-16T21:08:31.745Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | http://www.securityfocus.com/bid/106771 | Third Party Advisory, VDB Entry | |
ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSA-19-029-02 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/106771 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-19-029-02 | Third Party Advisory, US Government Resource |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:q03udvcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A3F6589C-3572-42CC-B880-5B2C3549474C", "versionEndIncluding": "20081", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:q03udvcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "0084E961-8F69-4EFE-A40E-1CF9A06453E0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:q04udvcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "87073025-987A-4BEF-964E-883C8E7756DA", "versionEndIncluding": "20081", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:q04udvcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "96E8978F-B03D-4B1F-ABBA-D817E614286C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:q06udvcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE0FDFA3-0ED9-4021-8D72-C4F69B6B3459", "versionEndIncluding": "20081", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:q06udvcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "CC119CA6-BFF3-4CFE-95E5-A10EEE52347F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:q13udvcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "28EC5DB9-D294-4B47-80A8-DD22150A95B4", "versionEndIncluding": "20081", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:q13udvcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "97BCF977-E6AE-443E-8348-F7E13830BC23", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:q26udvcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "689E8111-2B67-4032-8B63-668FF0EDEDFD", "versionEndIncluding": "20081", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:q26udvcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "B48AD3F4-81A2-43D2-A8B6-F7630CF4E742", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:q04udpvcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AE674A26-ADB7-46F1-8732-E349B36FB19D", "versionEndIncluding": "20081", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:q04udpvcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "D6EF53BB-1A67-4677-871A-CB73A7C58D42", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:q06udpvcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "15597B31-88EF-46AC-8FED-C3F0FD2D7BB7", "versionEndIncluding": "20081", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:q06udpvcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "052E37E0-9D05-4EB6-ADB3-B4465A19DC0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:q13udpvcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9BC22445-3EF3-4C25-8D0D-9168D24BA6E3", "versionEndIncluding": "20081", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:q13udpvcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "661C0146-FCCC-45BE-9EF6-113BD227E546", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:q26udpvcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C6DEC53B-5BCF-463B-A9B2-33E8BDE6E62C", "versionEndIncluding": "20081", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:q26udpvcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "D392BED4-C8A7-4A66-8A59-E2B569696E79", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:q03udecpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0F243D37-4DEB-4417-B293-A744752A21CB", "versionEndIncluding": "20101", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:q03udecpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "946DA26E-A6B2-46F6-BA81-A92133124823", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:q04udehcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B073F2B0-FBED-4D2D-B162-E3AF4BAFE2AD", "versionEndIncluding": "20101", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:q04udehcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "82399072-1B4D-46A4-A37C-FC706915B162", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:q06udehcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "405F5551-5878-4EC2-98F2-2C8738367CBB", "versionEndIncluding": "20101", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:q06udehcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "210FBF45-F646-4179-8139-E9022EA2E9AE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:q10udehcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "30FA774C-8EA6-4276-AE24-DC77C9759D3B", "versionEndIncluding": "20101", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:q10udehcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "E92D0D5D-E6A0-4E5D-83D9-6653E816FEF5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:q13udehcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DDA2969A-877C-44DF-8493-38F573D5F866", "versionEndIncluding": "20101", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:q13udehcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "DD3ACF11-7E9F-45A0-B4C2-B804B3609791", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:q20udehcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D93EF2BD-FDFB-4475-9E4F-73235AE5FF24", "versionEndIncluding": "20101", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:q20udehcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "1696B87B-AF68-4341-9E13-E2B25FEA623A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:q26udehcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "432285C7-DD4C-4C7F-AF98-3ED9D3F68185", "versionEndIncluding": "20101", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:q26udehcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "795ED888-B01E-4EBA-8FB5-42D196169761", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:q50udehcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7844E75B-B110-4BD6-A01B-8A71317604D0", "versionEndIncluding": "20101", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:q50udehcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "401FB06F-F2F8-4C1E-B36B-4E3E4007F772", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:q100udehcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "943C4F6E-AE15-4CB1-A4DE-E94E5FCFFB71", "versionEndIncluding": "20101", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:q100udehcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "6E58A172-EEAF-4211-9F3A-66CF57456AFB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Mitsubishi Electric Q03/04/06/13/26UDVCPU: serial number 20081 and prior, Q04/06/13/26UDPVCPU: serial number 20081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 20101 and prior. A remote attacker can send specific bytes over Port 5007 that will result in an Ethernet stack crash." }, { "lang": "es", "value": "Mitsubishi Electric Q03/04/06/13/26UDVCPU: n\u00famero de serie 20081 y anteriores, Q04/06/13/26UDPVCPU: n\u00famero de serie 20081 y anteriores y Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: n\u00famero de serie 20101 y anteriores. Un atacante remoto puede mandar bites espec\u00edficos a trav\u00e9s del puerto 5007 que resultar\u00e1 en un cierre inesperado de la pila de ethernet." } ], "id": "CVE-2019-6535", "lastModified": "2024-11-21T04:46:38.847", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2019-02-05T19:29:00.243", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/106771" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-029-02" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/106771" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-029-02" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
var-201902-0127
Vulnerability from variot
Mitsubishi Electric Q03/04/06/13/26UDVCPU: serial number 20081 and prior, Q04/06/13/26UDPVCPU: serial number 20081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 20101 and prior. A remote attacker can send specific bytes over Port 5007 that will result in an Ethernet stack crash. plural Mitsubishi Electric Q Series products are vulnerable to resource exhaustion.Service operation interruption (DoS) There is a possibility of being put into a state. Mitsubishi Electric MELSEC-Q Series PLCs are prone to an remote denial-of-service vulnerability. An attacker can exploit this issue to cause a denial-of-service condition. Misubishi Electric Q03UDVCPU, etc. are all PLC (programmable logic controller) products of Japan's Mitsubishi Electric (Misubishi Electric) company. Security flaws exist in several Misubishi products. A remote attacker could exploit this vulnerability by sending a specially crafted packet to cause Ethernet to stop communicating. The following products are affected: Misubishi Q03UDVCPU; Q04UDVCPU; Q06UDVCPU; Q13UDVCPU; Q26UDPVCPU; Q03UDECPU;
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201902-0127", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "q26udpvcpu", "scope": "lte", "trust": 1.0, "vendor": "mitsubishielectric", "version": "20081" }, { "model": "q06udpvcpu", "scope": "lte", "trust": 1.0, "vendor": "mitsubishielectric", "version": "20081" }, { "model": "q04udehcpu", "scope": "lte", "trust": 1.0, "vendor": "mitsubishielectric", "version": "20101" }, { "model": "q10udehcpu", "scope": "lte", "trust": 1.0, "vendor": "mitsubishielectric", "version": "20101" }, { "model": "q13udpvcpu", "scope": "lte", "trust": 1.0, "vendor": "mitsubishielectric", "version": "20081" }, { "model": "q03udecpu", "scope": "lte", "trust": 1.0, "vendor": "mitsubishielectric", "version": "20101" }, { "model": "q13udehcpu", "scope": "lte", "trust": 1.0, "vendor": "mitsubishielectric", "version": "20101" }, { "model": "q20udehcpu", "scope": "lte", "trust": 1.0, "vendor": "mitsubishielectric", "version": "20101" }, { "model": "q100udehcpu", "scope": "lte", "trust": 1.0, "vendor": "mitsubishielectric", "version": "20101" }, { "model": "q26udvcpu", "scope": "lte", "trust": 1.0, "vendor": "mitsubishielectric", "version": "20081" }, { "model": "q04udvcpu", "scope": "lte", "trust": 1.0, "vendor": "mitsubishielectric", "version": "20081" }, { "model": "q03udvcpu", "scope": "lte", "trust": 1.0, "vendor": "mitsubishielectric", "version": "20081" }, { "model": "q13udvcpu", "scope": "lte", "trust": 1.0, "vendor": "mitsubishielectric", "version": "20081" }, { "model": "q06udvcpu", "scope": "lte", "trust": 1.0, "vendor": "mitsubishielectric", "version": "20081" }, { "model": "q04udpvcpu", "scope": "lte", "trust": 1.0, "vendor": "mitsubishielectric", "version": "20081" }, { "model": "q26udehcpu", "scope": "lte", "trust": 1.0, "vendor": "mitsubishielectric", "version": "20101" }, { "model": "q06udehcpu", "scope": "lte", "trust": 1.0, "vendor": "mitsubishielectric", "version": "20101" }, { "model": "q50udehcpu", "scope": "lte", "trust": 1.0, "vendor": "mitsubishielectric", "version": "20101" }, { "model": "q03udecpu", "scope": null, "trust": 0.8, "vendor": "mitsubishi electric", "version": null }, { "model": "q03udvcpu", "scope": null, "trust": 0.8, "vendor": "mitsubishi electric", "version": null }, { "model": "q04udpvcpu", "scope": null, "trust": 0.8, "vendor": "mitsubishi electric", "version": null }, { "model": "q04udvcpu", "scope": null, "trust": 0.8, "vendor": "mitsubishi electric", "version": null }, { "model": "q06udpvcpu", "scope": null, "trust": 0.8, "vendor": "mitsubishi electric", "version": null }, { "model": "q06udvcpu", "scope": null, "trust": 0.8, "vendor": "mitsubishi electric", "version": null }, { "model": "q13udpvcpu", "scope": null, "trust": 0.8, "vendor": "mitsubishi electric", "version": null }, { "model": "q13udvcpu", "scope": null, "trust": 0.8, "vendor": "mitsubishi electric", "version": null }, { "model": "q26udpvcpu", "scope": null, "trust": 0.8, "vendor": "mitsubishi electric", "version": null }, { "model": "q26udvcpu", "scope": null, "trust": 0.8, "vendor": "mitsubishi electric", "version": null }, { "model": "electric q04/06/13/26udpvcpu", "scope": "eq", "trust": 0.3, "vendor": "mitsubishi", "version": "20081" }, { "model": "electric q04/06/10/13/20/26/50/100udehcpu", "scope": "eq", "trust": 0.3, "vendor": "mitsubishi", "version": "20101" }, { "model": "electric q03udecpu", "scope": "eq", "trust": 0.3, "vendor": "mitsubishi", "version": "20101" }, { "model": "electric q03/04/06/13/26udvcpu", "scope": "eq", "trust": 0.3, "vendor": "mitsubishi", "version": "20081" } ], "sources": [ { "db": "BID", "id": "106771" }, { "db": "JVNDB", "id": "JVNDB-2019-001917" }, { "db": "NVD", "id": "CVE-2019-6535" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:mitsubishielectric:q03udecpu_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:mitsubishielectric:q03udvcpu_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:mitsubishielectric:q04udpvcpu_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:mitsubishielectric:q04udvcpu_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:mitsubishielectric:q06udpvcpu_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:mitsubishielectric:q06udvcpu_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:mitsubishielectric:q13udpvcpu_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:mitsubishielectric:q13udvcpu_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:mitsubishielectric:q26udpvcpu_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:mitsubishielectric:q26udvcpu_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-001917" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tri Quach of Amazon???s Customer Fulfillment Technology Security (CFTS),Tri Quach of Amazon???s Customer Fulfillment Technology Security (CFTS)", "sources": [ { "db": "CNNVD", "id": "CNNVD-201901-973" } ], "trust": 0.6 }, "cve": "CVE-2019-6535", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2019-6535", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "VHN-157970", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2019-6535", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2019-6535", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2019-6535", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2019-6535", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-201901-973", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-157970", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULHUB", "id": "VHN-157970" }, { "db": "JVNDB", "id": "JVNDB-2019-001917" }, { "db": "CNNVD", "id": "CNNVD-201901-973" }, { "db": "NVD", "id": "CVE-2019-6535" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Mitsubishi Electric Q03/04/06/13/26UDVCPU: serial number 20081 and prior, Q04/06/13/26UDPVCPU: serial number 20081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 20101 and prior. A remote attacker can send specific bytes over Port 5007 that will result in an Ethernet stack crash. plural Mitsubishi Electric Q Series products are vulnerable to resource exhaustion.Service operation interruption (DoS) There is a possibility of being put into a state. Mitsubishi Electric MELSEC-Q Series PLCs are prone to an remote denial-of-service vulnerability. \nAn attacker can exploit this issue to cause a denial-of-service condition. Misubishi Electric Q03UDVCPU, etc. are all PLC (programmable logic controller) products of Japan\u0027s Mitsubishi Electric (Misubishi Electric) company. Security flaws exist in several Misubishi products. A remote attacker could exploit this vulnerability by sending a specially crafted packet to cause Ethernet to stop communicating. The following products are affected: Misubishi Q03UDVCPU; Q04UDVCPU; Q06UDVCPU; Q13UDVCPU; Q26UDPVCPU; Q03UDECPU;", "sources": [ { "db": "NVD", "id": "CVE-2019-6535" }, { "db": "JVNDB", "id": "JVNDB-2019-001917" }, { "db": "BID", "id": "106771" }, { "db": "VULHUB", "id": "VHN-157970" } ], "trust": 1.98 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2019-6535", "trust": 2.8 }, { "db": "ICS CERT", "id": "ICSA-19-029-02", "trust": 2.8 }, { "db": "BID", "id": "106771", "trust": 2.0 }, { "db": "JVNDB", "id": "JVNDB-2019-001917", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201901-973", "trust": 0.7 }, { "db": "SEEBUG", "id": "SSVID-98808", "trust": 0.1 }, { "db": "VULHUB", "id": "VHN-157970", "trust": 0.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-157970" }, { "db": "BID", "id": "106771" }, { "db": "JVNDB", "id": "JVNDB-2019-001917" }, { "db": "CNNVD", "id": "CNNVD-201901-973" }, { "db": "NVD", "id": "CVE-2019-6535" } ] }, "id": "VAR-201902-0127", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-157970" } ], "trust": 0.85 }, "last_update_date": "2024-11-23T23:08:27.703000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "MELSEC-Q\u30b7\u30ea\u30fc\u30ba", "trust": 0.8, "url": "https://www.mitsubishielectric.co.jp/fa/products/cnt/plcq/items/index.html" }, { "title": "Multiple Misubishi Product security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=89040" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-001917" }, { "db": "CNNVD", "id": "CNNVD-201901-973" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-400", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-157970" }, { "db": "JVNDB", "id": "JVNDB-2019-001917" }, { "db": "NVD", "id": "CVE-2019-6535" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.8, "url": "https://ics-cert.us-cert.gov/advisories/icsa-19-029-02" }, { "trust": 2.3, "url": "http://www.securityfocus.com/bid/106771" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-6535" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-6535" }, { "trust": 0.3, "url": "http://www.mitsubishi-automation.com/" } ], "sources": [ { "db": "VULHUB", "id": "VHN-157970" }, { "db": "BID", "id": "106771" }, { "db": "JVNDB", "id": "JVNDB-2019-001917" }, { "db": "CNNVD", "id": "CNNVD-201901-973" }, { "db": "NVD", "id": "CVE-2019-6535" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULHUB", "id": "VHN-157970" }, { "db": "BID", "id": "106771" }, { "db": "JVNDB", "id": "JVNDB-2019-001917" }, { "db": "CNNVD", "id": "CNNVD-201901-973" }, { "db": "NVD", "id": "CVE-2019-6535" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-02-05T00:00:00", "db": "VULHUB", "id": "VHN-157970" }, { "date": "2019-01-29T00:00:00", "db": "BID", "id": "106771" }, { "date": "2019-03-29T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-001917" }, { "date": "2019-01-30T00:00:00", "db": "CNNVD", "id": "CNNVD-201901-973" }, { "date": "2019-02-05T19:29:00.243000", "db": "NVD", "id": "CVE-2019-6535" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-01-31T00:00:00", "db": "VULHUB", "id": "VHN-157970" }, { "date": "2019-01-29T00:00:00", "db": "BID", "id": "106771" }, { "date": "2019-03-29T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-001917" }, { "date": "2019-10-17T00:00:00", "db": "CNNVD", "id": "CNNVD-201901-973" }, { "date": "2024-11-21T04:46:38.847000", "db": "NVD", "id": "CVE-2019-6535" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201901-973" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Mitsubishi Electric Q Vulnerability related to resource depletion in series products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-001917" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "resource management error", "sources": [ { "db": "CNNVD", "id": "CNNVD-201901-973" } ], "trust": 0.6 } }