Search

Find a vulnerability

Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    4 vulnerabilities found for optimization_for_tensorflow by intel

    CVE-2023-30767 (GCVE-0-2023-30767)

    Vulnerability from cvelistv5 – Published: 2024-02-14 13:37 – Updated: 2024-08-14 19:16
    VLAI
    Summary
    Improper buffer restrictions in Intel(R) Optimization for TensorFlow before version 2.13.0 may allow an authenticated user to potentially enable escalation of privilege via local access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • escalation of privilege
    • CWE-92 - Improper buffer restrictions
    Assigner
    Impacted products
    Vendor Product Version
    n/a TensorFlow Affected: before version 2.13.0
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T14:37:15.512Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00903.html",
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00903.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-30767",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-14T19:16:37.972621Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-14T19:16:55.856Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "TensorFlow",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "before version 2.13.0"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper buffer restrictions in Intel(R) Optimization for TensorFlow before version 2.13.0 may allow an authenticated user to potentially enable escalation of privilege via local access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "LOW",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:L/I:H/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "escalation of privilege",
                  "lang": "en"
                },
                {
                  "cweId": "CWE-92",
                  "description": "Improper buffer restrictions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-02-14T13:37:50.498Z",
            "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
            "shortName": "intel"
          },
          "references": [
            {
              "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00903.html",
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00903.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "assignerShortName": "intel",
        "cveId": "CVE-2023-30767",
        "datePublished": "2024-02-14T13:37:50.498Z",
        "dateReserved": "2023-05-05T03:00:03.650Z",
        "dateUpdated": "2024-08-14T19:16:55.856Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-27506 (GCVE-0-2023-27506)

    Vulnerability from cvelistv5 – Published: 2023-08-11 02:37 – Updated: 2024-10-02 13:38
    VLAI
    Summary
    Improper buffer restrictions in the Intel(R) Optimization for Tensorflow software before version 2.12 may allow an authenticated user to potentially enable escalation of privilege via local access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • escalation of privilege
    • CWE-92 - Improper buffer restrictions
    Assigner
    Impacted products
    Vendor Product Version
    n/a Intel(R) Optimization for Tensorflow software Affected: before version 2.12
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T12:16:36.899Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "http://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00840.html",
                "tags": [
                  "x_transferred"
                ],
                "url": "http://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00840.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-27506",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-02T13:33:45.661405Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-02T13:38:01.152Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Intel(R) Optimization for Tensorflow software",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "before version 2.12"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper buffer restrictions in the Intel(R) Optimization for Tensorflow software before version 2.12 may allow an authenticated user to potentially enable escalation of privilege via local access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "LOW",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:L/I:H/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "escalation of privilege",
                  "lang": "en"
                },
                {
                  "cweId": "CWE-92",
                  "description": "Improper buffer restrictions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-11T02:37:08.711Z",
            "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
            "shortName": "intel"
          },
          "references": [
            {
              "name": "http://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00840.html",
              "url": "http://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00840.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "assignerShortName": "intel",
        "cveId": "CVE-2023-27506",
        "datePublished": "2023-08-11T02:37:08.711Z",
        "dateReserved": "2023-03-02T04:00:03.105Z",
        "dateUpdated": "2024-10-02T13:38:01.152Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-30767 (GCVE-0-2023-30767)

    Vulnerability from nvd – Published: 2024-02-14 13:37 – Updated: 2024-08-14 19:16
    VLAI
    Summary
    Improper buffer restrictions in Intel(R) Optimization for TensorFlow before version 2.13.0 may allow an authenticated user to potentially enable escalation of privilege via local access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • escalation of privilege
    • CWE-92 - Improper buffer restrictions
    Assigner
    Impacted products
    Vendor Product Version
    n/a TensorFlow Affected: before version 2.13.0
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T14:37:15.512Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00903.html",
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00903.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-30767",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-14T19:16:37.972621Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-14T19:16:55.856Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "TensorFlow",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "before version 2.13.0"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper buffer restrictions in Intel(R) Optimization for TensorFlow before version 2.13.0 may allow an authenticated user to potentially enable escalation of privilege via local access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "LOW",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:L/I:H/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "escalation of privilege",
                  "lang": "en"
                },
                {
                  "cweId": "CWE-92",
                  "description": "Improper buffer restrictions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-02-14T13:37:50.498Z",
            "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
            "shortName": "intel"
          },
          "references": [
            {
              "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00903.html",
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00903.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "assignerShortName": "intel",
        "cveId": "CVE-2023-30767",
        "datePublished": "2024-02-14T13:37:50.498Z",
        "dateReserved": "2023-05-05T03:00:03.650Z",
        "dateUpdated": "2024-08-14T19:16:55.856Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-27506 (GCVE-0-2023-27506)

    Vulnerability from nvd – Published: 2023-08-11 02:37 – Updated: 2024-10-02 13:38
    VLAI
    Summary
    Improper buffer restrictions in the Intel(R) Optimization for Tensorflow software before version 2.12 may allow an authenticated user to potentially enable escalation of privilege via local access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • escalation of privilege
    • CWE-92 - Improper buffer restrictions
    Assigner
    Impacted products
    Vendor Product Version
    n/a Intel(R) Optimization for Tensorflow software Affected: before version 2.12
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T12:16:36.899Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "http://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00840.html",
                "tags": [
                  "x_transferred"
                ],
                "url": "http://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00840.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-27506",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-02T13:33:45.661405Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-02T13:38:01.152Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Intel(R) Optimization for Tensorflow software",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "before version 2.12"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper buffer restrictions in the Intel(R) Optimization for Tensorflow software before version 2.12 may allow an authenticated user to potentially enable escalation of privilege via local access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "LOW",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:L/I:H/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "escalation of privilege",
                  "lang": "en"
                },
                {
                  "cweId": "CWE-92",
                  "description": "Improper buffer restrictions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-11T02:37:08.711Z",
            "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
            "shortName": "intel"
          },
          "references": [
            {
              "name": "http://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00840.html",
              "url": "http://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00840.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "assignerShortName": "intel",
        "cveId": "CVE-2023-27506",
        "datePublished": "2023-08-11T02:37:08.711Z",
        "dateReserved": "2023-03-02T04:00:03.105Z",
        "dateUpdated": "2024-10-02T13:38:01.152Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }