Vulnerabilites related to mitsubishi-automation - mx4_scada
Vulnerability from fkie_nvd
Published
2012-09-15 17:55
Modified
2024-11-21 01:33
Severity ?
Summary
Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA before 7.20 allows local users to execute arbitrary code via a long string in a login sequence.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
mitsubishi-automation | mx4_scada | * | |
schneider-electric | citectscada | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:mitsubishi-automation:mx4_scada:*:*:*:*:*:*:*:*", "matchCriteriaId": "395C96CE-DE55-4880-B76C-A6FFAB5F7C29", "versionEndIncluding": "7.10", "vulnerable": true }, { "criteria": "cpe:2.3:a:schneider-electric:citectscada:*:*:*:*:*:*:*:*", "matchCriteriaId": "1B3CD645-0057-4C5C-B815-A7B50D3387F6", "versionEndIncluding": "7.10", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA before 7.20 allows local users to execute arbitrary code via a long string in a login sequence." }, { "lang": "es", "value": "Desbordamiento de b\u00fafer en un componente de terceros no especificado en el m\u00f3dulo de ejecuci\u00f3n por lote para Schneider Electric CitectSCADA anterior a v7.20 y Mitsubishi MX4 SCADA anterior a v7.20 permite a usuarios locales ejecutar c\u00f3digo arbitrario a trav\u00e9s de una cadena larga en una secuencia de acceso." } ], "id": "CVE-2011-5163", "lastModified": "2024-11-21T01:33:47.497", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 4.6, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ] }, "published": "2012-09-15T17:55:04.287", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "http://secunia.com/advisories/46779" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "http://secunia.com/advisories/46786" }, { "source": "cve@mitre.org", "url": "http://www.citect.com/citectscada-batch" }, { "source": "cve@mitre.org", "url": "http://www.osvdb.org/76937" }, { "source": "cve@mitre.org", "url": "http://www.securitytracker.com/id?1026306" }, { "source": "cve@mitre.org", "tags": [ "US Government Resource" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-279-02.pdf" }, { "source": "cve@mitre.org", "url": "https://my.mitsubishi-automation.com/downloads_show.php?portal_id=1\u0026doc_type=safety\u0026scat=2\u0026sstr=MX4%2CSCADA" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "http://secunia.com/advisories/46779" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "http://secunia.com/advisories/46786" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://www.citect.com/citectscada-batch" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://www.osvdb.org/76937" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://www.securitytracker.com/id?1026306" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "US Government Resource" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-279-02.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://my.mitsubishi-automation.com/downloads_show.php?portal_id=1\u0026doc_type=safety\u0026scat=2\u0026sstr=MX4%2CSCADA" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
cve-2011-5163
Vulnerability from cvelistv5
Published
2012-09-15 17:00
Modified
2024-09-17 00:35
Severity ?
EPSS score ?
Summary
Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA before 7.20 allows local users to execute arbitrary code via a long string in a login sequence.
References
▼ | URL | Tags |
---|---|---|
http://www.citect.com/citectscada-batch | x_refsource_CONFIRM | |
http://www.osvdb.org/76937 | vdb-entry, x_refsource_OSVDB | |
http://www.us-cert.gov/control_systems/pdf/ICSA-11-279-02.pdf | x_refsource_MISC | |
http://secunia.com/advisories/46779 | third-party-advisory, x_refsource_SECUNIA | |
http://www.securitytracker.com/id?1026306 | vdb-entry, x_refsource_SECTRACK | |
https://my.mitsubishi-automation.com/downloads_show.php?portal_id=1&doc_type=safety&scat=2&sstr=MX4%2CSCADA | x_refsource_CONFIRM | |
http://secunia.com/advisories/46786 | third-party-advisory, x_refsource_SECUNIA |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-07T00:30:46.763Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://www.citect.com/citectscada-batch" }, { "name": "76937", "tags": [ "vdb-entry", "x_refsource_OSVDB", "x_transferred" ], "url": "http://www.osvdb.org/76937" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-279-02.pdf" }, { "name": "46779", "tags": [ "third-party-advisory", "x_refsource_SECUNIA", "x_transferred" ], "url": "http://secunia.com/advisories/46779" }, { "name": "1026306", "tags": [ "vdb-entry", "x_refsource_SECTRACK", "x_transferred" ], "url": "http://www.securitytracker.com/id?1026306" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://my.mitsubishi-automation.com/downloads_show.php?portal_id=1\u0026doc_type=safety\u0026scat=2\u0026sstr=MX4%2CSCADA" }, { "name": "46786", "tags": [ "third-party-advisory", "x_refsource_SECUNIA", "x_transferred" ], "url": "http://secunia.com/advisories/46786" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA before 7.20 allows local users to execute arbitrary code via a long string in a login sequence." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2012-09-15T17:00:00Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "http://www.citect.com/citectscada-batch" }, { "name": "76937", "tags": [ "vdb-entry", "x_refsource_OSVDB" ], "url": "http://www.osvdb.org/76937" }, { "tags": [ "x_refsource_MISC" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-279-02.pdf" }, { "name": "46779", "tags": [ "third-party-advisory", "x_refsource_SECUNIA" ], "url": "http://secunia.com/advisories/46779" }, { "name": "1026306", "tags": [ "vdb-entry", "x_refsource_SECTRACK" ], "url": "http://www.securitytracker.com/id?1026306" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://my.mitsubishi-automation.com/downloads_show.php?portal_id=1\u0026doc_type=safety\u0026scat=2\u0026sstr=MX4%2CSCADA" }, { "name": "46786", "tags": [ "third-party-advisory", "x_refsource_SECUNIA" ], "url": "http://secunia.com/advisories/46786" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2011-5163", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA before 7.20 allows local users to execute arbitrary code via a long string in a login sequence." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "http://www.citect.com/citectscada-batch", "refsource": "CONFIRM", "url": "http://www.citect.com/citectscada-batch" }, { "name": "76937", "refsource": "OSVDB", "url": "http://www.osvdb.org/76937" }, { "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-279-02.pdf", "refsource": "MISC", "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-279-02.pdf" }, { "name": "46779", "refsource": "SECUNIA", "url": "http://secunia.com/advisories/46779" }, { "name": "1026306", "refsource": "SECTRACK", "url": "http://www.securitytracker.com/id?1026306" }, { "name": "https://my.mitsubishi-automation.com/downloads_show.php?portal_id=1\u0026doc_type=safety\u0026scat=2\u0026sstr=MX4,SCADA", "refsource": "CONFIRM", "url": "https://my.mitsubishi-automation.com/downloads_show.php?portal_id=1\u0026doc_type=safety\u0026scat=2\u0026sstr=MX4,SCADA" }, { "name": "46786", "refsource": "SECUNIA", "url": "http://secunia.com/advisories/46786" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2011-5163", "datePublished": "2012-09-15T17:00:00Z", "dateReserved": "2012-09-15T00:00:00Z", "dateUpdated": "2024-09-17T00:35:30.905Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }