Vulnerabilites related to ge - intelligent_platforms_proficy_hmi\%2fscada_cimplicity
Vulnerability from fkie_nvd
Published
2014-01-25 22:55
Modified
2024-11-21 02:02
Severity ?
Summary
Directory traversal vulnerability in CimWebServer.exe (aka the WebView component) in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY before 8.2 SIM 24, and Proficy Process Systems with CIMPLICITY, allows remote attackers to execute arbitrary code via a crafted message to TCP port 10212, aka ZDI-CAN-1623.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\%2fscada_cimplicity:*:sim24:*:*:*:*:*:*",
              "matchCriteriaId": "4C5EDB9D-01CD-4843-86CD-C834B726ACF1",
              "versionEndIncluding": "8.2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_cimplicity:4.01:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C0B8CA7-2161-4603-B844-DE6C079DF36F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_cimplicity:7.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "E3BACB11-5CD3-4CA6-9C56-D71628CADF0F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_cimplicity:8.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "90538C50-38BD-4EE5-BD30-96E2E2951FE3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_cimplicity:8.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB261867-B9B1-4D3D-B2DE-3CC3164EFD06",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_cimplicity:8.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "559DCD7A-0745-4D4C-A77A-83240EF6C510",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_process_systems_with_cimplicity:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD9711EA-2C95-41FA-8827-01FCB0ED4B06",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Directory traversal vulnerability in CimWebServer.exe (aka the WebView component) in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY before 8.2 SIM 24, and Proficy Process Systems with CIMPLICITY, allows remote attackers to execute arbitrary code via a crafted message to TCP port 10212, aka ZDI-CAN-1623."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de salto de directorio en CimWebServer.exe (tambi\u00e9n conocido como el componente WebView) en GE Intelligent Platforms Proficy HMI / SCADA - CIMPLICITY anterior a  8.2 SIM  24 y Proficy Process con CIMPLICITY, permite a atacantes remotos ejecutar c\u00f3digo arbitrario a trav\u00e9s de un mensaje manipulado a puerto TCP 10212  , tambi\u00e9n conocido como ZDI-CAN-1623."
    }
  ],
  "id": "CVE-2014-0751",
  "lastModified": "2024-11-21T02:02:44.600",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2014-01-25T22:55:04.583",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-023-01"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://support.ge-ip.com/support/index?page=kbchannel\u0026id=KB15940"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "url": "http://www.securityfocus.com/bid/65117"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-023-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://support.ge-ip.com/support/index?page=kbchannel\u0026id=KB15940"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.securityfocus.com/bid/65117"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-22"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2014-01-25 22:55
Modified
2024-11-21 02:02
Severity ?
Summary
Directory traversal vulnerability in gefebt.exe in the WebView CimWeb components in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY through 8.2 SIM 24, and Proficy Process Systems with CIMPLICITY, allows remote attackers to execute arbitrary code via a crafted HTTP request, aka ZDI-CAN-1622.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\%2fscada_cimplicity:*:sim24:*:*:*:*:*:*",
              "matchCriteriaId": "4C5EDB9D-01CD-4843-86CD-C834B726ACF1",
              "versionEndIncluding": "8.2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_cimplicity:4.01:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C0B8CA7-2161-4603-B844-DE6C079DF36F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_cimplicity:7.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "E3BACB11-5CD3-4CA6-9C56-D71628CADF0F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_cimplicity:8.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "90538C50-38BD-4EE5-BD30-96E2E2951FE3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_cimplicity:8.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB261867-B9B1-4D3D-B2DE-3CC3164EFD06",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_cimplicity:8.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "559DCD7A-0745-4D4C-A77A-83240EF6C510",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_process_systems_with_cimplicity:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD9711EA-2C95-41FA-8827-01FCB0ED4B06",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Directory traversal vulnerability in gefebt.exe in the WebView CimWeb components in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY through 8.2 SIM 24, and Proficy Process Systems with CIMPLICITY, allows remote attackers to execute arbitrary code via a crafted HTTP request, aka ZDI-CAN-1622."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de recorrido de directorios en gefebt.exe en los componentes WebView CimWeb de GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY hasta 8.2 SIM 24, y Proficy Process Systems with CIMPLICITY, permite a atacantes remotos ejecutar c\u00f3digo de forma arbitraria a trav\u00e9s de una petici\u00f3n HTTP manipulada, tambien conocido como ZDI-CAN-1622."
    }
  ],
  "id": "CVE-2014-0750",
  "lastModified": "2024-11-21T02:02:44.483",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2014-01-25T22:55:04.550",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-023-01"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://support.ge-ip.com/support/index?page=kbchannel\u0026id=KB15939"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "url": "http://www.securityfocus.com/bid/65124"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-023-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://support.ge-ip.com/support/index?page=kbchannel\u0026id=KB15939"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.securityfocus.com/bid/65124"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-22"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

cve-2014-0751
Vulnerability from cvelistv5
Published
2014-01-25 22:00
Modified
2024-08-06 09:27
Severity ?
Summary
Directory traversal vulnerability in CimWebServer.exe (aka the WebView component) in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY before 8.2 SIM 24, and Proficy Process Systems with CIMPLICITY, allows remote attackers to execute arbitrary code via a crafted message to TCP port 10212, aka ZDI-CAN-1623.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T09:27:19.517Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-023-01"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://support.ge-ip.com/support/index?page=kbchannel\u0026id=KB15940"
          },
          {
            "name": "65117",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/65117"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2014-01-24T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Directory traversal vulnerability in CimWebServer.exe (aka the WebView component) in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY before 8.2 SIM 24, and Proficy Process Systems with CIMPLICITY, allows remote attackers to execute arbitrary code via a crafted message to TCP port 10212, aka ZDI-CAN-1623."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2014-02-18T17:57:02",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-023-01"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://support.ge-ip.com/support/index?page=kbchannel\u0026id=KB15940"
        },
        {
          "name": "65117",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/65117"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-0751",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Directory traversal vulnerability in CimWebServer.exe (aka the WebView component) in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY before 8.2 SIM 24, and Proficy Process Systems with CIMPLICITY, allows remote attackers to execute arbitrary code via a crafted message to TCP port 10212, aka ZDI-CAN-1623."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-023-01",
              "refsource": "MISC",
              "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-023-01"
            },
            {
              "name": "http://support.ge-ip.com/support/index?page=kbchannel\u0026id=KB15940",
              "refsource": "CONFIRM",
              "url": "http://support.ge-ip.com/support/index?page=kbchannel\u0026id=KB15940"
            },
            {
              "name": "65117",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/65117"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-0751",
    "datePublished": "2014-01-25T22:00:00",
    "dateReserved": "2014-01-02T00:00:00",
    "dateUpdated": "2024-08-06T09:27:19.517Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2014-0750
Vulnerability from cvelistv5
Published
2014-01-25 22:00
Modified
2024-08-06 09:27
Severity ?
Summary
Directory traversal vulnerability in gefebt.exe in the WebView CimWeb components in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY through 8.2 SIM 24, and Proficy Process Systems with CIMPLICITY, allows remote attackers to execute arbitrary code via a crafted HTTP request, aka ZDI-CAN-1622.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T09:27:19.508Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-023-01"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://support.ge-ip.com/support/index?page=kbchannel\u0026id=KB15939"
          },
          {
            "name": "65124",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/65124"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2014-01-24T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Directory traversal vulnerability in gefebt.exe in the WebView CimWeb components in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY through 8.2 SIM 24, and Proficy Process Systems with CIMPLICITY, allows remote attackers to execute arbitrary code via a crafted HTTP request, aka ZDI-CAN-1622."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2014-02-18T17:57:02",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-023-01"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://support.ge-ip.com/support/index?page=kbchannel\u0026id=KB15939"
        },
        {
          "name": "65124",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/65124"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-0750",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Directory traversal vulnerability in gefebt.exe in the WebView CimWeb components in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY through 8.2 SIM 24, and Proficy Process Systems with CIMPLICITY, allows remote attackers to execute arbitrary code via a crafted HTTP request, aka ZDI-CAN-1622."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-023-01",
              "refsource": "MISC",
              "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-023-01"
            },
            {
              "name": "http://support.ge-ip.com/support/index?page=kbchannel\u0026id=KB15939",
              "refsource": "CONFIRM",
              "url": "http://support.ge-ip.com/support/index?page=kbchannel\u0026id=KB15939"
            },
            {
              "name": "65124",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/65124"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-0750",
    "datePublished": "2014-01-25T22:00:00",
    "dateReserved": "2014-01-02T00:00:00",
    "dateUpdated": "2024-08-06T09:27:19.508Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}