Vulnerabilites related to phoenixcontact - ilc_131_eth\/xc
Vulnerability from fkie_nvd
Published
2019-02-26 23:29
Modified
2024-11-21 04:51
Summary
Multiple Phoenix Contact devices allow remote attackers to establish TCP sessions to port 1962 and obtain sensitive information or make changes, as demonstrated by using the Create Backup feature to traverse all directories.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:ilc_131_eth_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "176DF3A4-F017-49AF-B91E-7E1935C5DE56",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:ilc_131_eth:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3D2A4938-D680-4AA2-82B0-7FE793AE9318",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:ilc_131_eth\\/xc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4FD92DFF-FED1-474D-A2E7-E9CEA11468AC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:ilc_131_eth\\/xc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "676A4E47-B36A-4C88-AD15-835843B92B97",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:ilc_151_eth_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB358CEE-2B29-4DAB-A100-36C841718D56",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:ilc_151_eth:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "301BA6C4-3E50-46CC-A6C9-E61948994F20",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:ilc_151_eth\\/xc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE1801C5-62D8-4F06-ADBA-E4D8476DB07E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:ilc_151_eth\\/xc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "35E34FD1-9A9A-426C-9788-FD75EAD712B5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:ilc_171_eth_2tx_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DF4B7D19-2237-4BF3-A3DF-21780618E4EE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:ilc_171_eth_2tx:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7457430D-A906-440F-8641-F7F412605A92",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:ilc_191_eth_2tx_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2F0DC047-2D73-42EC-B15B-FF8969F2B470",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:ilc_191_eth_2tx:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA647DB2-0612-4088-BCBC-E14F726FFD8D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:ilc_191_me\\/an_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "83317305-2342-4B3A-A806-E2853C54DCAD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:ilc_191_me\\/an:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "86A2D18D-61B4-4F51-8891-8FCD3E06A8B9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:axc_1050_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D0FC9C3-FA7C-4114-894D-3E04A8D05716",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:axc_1050:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5F55C821-DAA6-4098-BB54-80F6D9ED0CD6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Multiple Phoenix Contact devices allow remote attackers to establish TCP sessions to port 1962 and obtain sensitive information or make changes, as demonstrated by using the Create Backup feature to traverse all directories."
    },
    {
      "lang": "es",
      "value": "M\u00faltiples dispositivos Phoenix Contact permiten a los atacantes remotos establecer sesiones TCP al puerto 1962 y obtener informaci\u00f3n sensible o realizar cambios, como se ha demostrado al utilizar la funci\u00f3n Crear copia de seguridad para recorrer todos los directorios"
    }
  ],
  "id": "CVE-2019-9201",
  "lastModified": "2024-11-21T04:51:11.683",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 8.5,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "cve@mitre.org",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-02-26T23:29:00.357",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://cert.vde.com/en/advisories/VDE-2019-015/"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit"
      ],
      "url": "https://medium.com/%40SergiuSechel/misconfiguration-in-ilc-gsm-gprs-devices-leaves-over-1-200-ics-devices-vulnerable-to-attacks-over-82c2d4a91561"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://cert.vde.com/en/advisories/VDE-2019-015/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit"
      ],
      "url": "https://medium.com/%40SergiuSechel/misconfiguration-in-ilc-gsm-gprs-devices-leaves-over-1-200-ics-devices-vulnerable-to-attacks-over-82c2d4a91561"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-306"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

cve-2019-9201
Vulnerability from cvelistv5
Published
2019-02-26 23:00
Modified
2024-09-16 18:39
Severity ?
Summary
Multiple Phoenix Contact devices allow remote attackers to establish TCP sessions to port 1962 and obtain sensitive information or make changes, as demonstrated by using the Create Backup feature to traverse all directories.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T21:38:46.548Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://medium.com/%40SergiuSechel/misconfiguration-in-ilc-gsm-gprs-devices-leaves-over-1-200-ics-devices-vulnerable-to-attacks-over-82c2d4a91561"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en/advisories/VDE-2019-015/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2022-06-21T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Multiple Phoenix Contact devices allow remote attackers to establish TCP sessions to port 1962 and obtain sensitive information or make changes, as demonstrated by using the Create Backup feature to traverse all directories."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-21T08:05:10",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://medium.com/%40SergiuSechel/misconfiguration-in-ilc-gsm-gprs-devices-leaves-over-1-200-ics-devices-vulnerable-to-attacks-over-82c2d4a91561"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2019-015/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "DATE_PUBLIC": "2022-06-21T07:00:00.000Z",
          "ID": "CVE-2019-9201",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Multiple Phoenix Contact devices allow remote attackers to establish TCP sessions to port 1962 and obtain sensitive information or make changes, as demonstrated by using the Create Backup feature to traverse all directories."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://medium.com/@SergiuSechel/misconfiguration-in-ilc-gsm-gprs-devices-leaves-over-1-200-ics-devices-vulnerable-to-attacks-over-82c2d4a91561",
              "refsource": "MISC",
              "url": "https://medium.com/@SergiuSechel/misconfiguration-in-ilc-gsm-gprs-devices-leaves-over-1-200-ics-devices-vulnerable-to-attacks-over-82c2d4a91561"
            },
            {
              "name": "https://cert.vde.com/en/advisories/VDE-2019-015/",
              "refsource": "CONFIRM",
              "url": "https://cert.vde.com/en/advisories/VDE-2019-015/"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2019-9201",
    "datePublished": "2019-02-26T23:00:00Z",
    "dateReserved": "2019-02-26T00:00:00",
    "dateUpdated": "2024-09-16T18:39:47.456Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}