Vulnerabilites related to schneider-electric - harmony_hmiscu
cve-2021-22705
Vulnerability from cvelistv5
Published
2021-05-26 19:19
Modified
2024-08-03 18:51
Severity ?
EPSS score ?
Summary
Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause denial of service or unauthorized access to system information when interacting directly with a driver installed by Vijeo Designer or EcoStruxure Machine Expert
References
▼ | URL | Tags |
---|---|---|
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-02 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Harmony HMI Products Configured by Vijeo Designer (all versions prior to V6.2 SP11 ) or EcoStruxure Machine Expert (all versions prior to V2.0) |
Version: Harmony HMI Products Configured by Vijeo Designer (all versions prior to V6.2 SP11 ) or EcoStruxure Machine Expert (all versions prior to V2.0) |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.333Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Harmony HMI Products Configured by Vijeo Designer (all versions prior to V6.2 SP11 ) or EcoStruxure Machine Expert (all versions prior to V2.0)", "vendor": "n/a", "versions": [ { "status": "affected", "version": "Harmony HMI Products Configured by Vijeo Designer (all versions prior to V6.2 SP11 ) or EcoStruxure Machine Expert (all versions prior to V2.0)" } ] } ], "descriptions": [ { "lang": "en", "value": "Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause denial of service or unauthorized access to system information when interacting directly with a driver installed by Vijeo Designer or EcoStruxure Machine Expert" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-119", "description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-05-26T19:19:18", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-02" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22705", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Harmony HMI Products Configured by Vijeo Designer (all versions prior to V6.2 SP11 ) or EcoStruxure Machine Expert (all versions prior to V2.0)", "version": { "version_data": [ { "version_value": "Harmony HMI Products Configured by Vijeo Designer (all versions prior to V6.2 SP11 ) or EcoStruxure Machine Expert (all versions prior to V2.0)" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause denial of service or unauthorized access to system information when interacting directly with a driver installed by Vijeo Designer or EcoStruxure Machine Expert" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-02", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-02" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22705", "datePublished": "2021-05-26T19:19:18", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.333Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2021-05-26 20:15
Modified
2024-11-21 05:50
Severity ?
Summary
Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause denial of service or unauthorized access to system information when interacting directly with a driver installed by Vijeo Designer or EcoStruxure Machine Expert
References
▼ | URL | Tags | |
---|---|---|---|
cybersecurity@se.com | https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-02 | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-02 | Patch, Vendor Advisory |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:vijeo_designer:*:*:*:*:*:*:*:*", "matchCriteriaId": "C5F2F861-8F3B-40B0-9CC4-DB9776052C7A", "versionEndExcluding": "6.2.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:harmony_gk:-:*:*:*:*:*:*:*", "matchCriteriaId": "FDBAEC72-A63C-464D-8E62-C42959D4A871", "vulnerable": false }, { "criteria": "cpe:2.3:h:schneider-electric:harmony_gto:-:*:*:*:*:*:*:*", "matchCriteriaId": "3DDF1060-1FF5-41D5-A8ED-129492CC50A4", "vulnerable": false }, { "criteria": "cpe:2.3:h:schneider-electric:harmony_gtu:-:*:*:*:*:*:*:*", "matchCriteriaId": "9FCFA535-319D-4AB7-AB6C-B4BB0739B7F4", "vulnerable": false }, { "criteria": "cpe:2.3:h:schneider-electric:harmony_gtux:-:*:*:*:*:*:*:*", "matchCriteriaId": "AEA285A2-8EA7-473D-87A5-62E970BD25C3", "vulnerable": false }, { "criteria": "cpe:2.3:h:schneider-electric:harmony_sto:-:*:*:*:*:*:*:*", "matchCriteriaId": "68382B8C-4FB2-49AC-8CAE-2251400BE342", "vulnerable": false }, { "criteria": "cpe:2.3:h:schneider-electric:harmony_stu:-:*:*:*:*:*:*:*", "matchCriteriaId": "EB2002BD-8A77-414F-A530-A7D9350143F5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_machine_expert:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4DB52BF-192B-4167-872E-AAEC81ACAE7F", "versionEndExcluding": "2.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:harmony_hmiscu:-:*:*:*:*:*:*:*", "matchCriteriaId": "63E063B8-1179-48D2-A672-177AA1A0FCE1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause denial of service or unauthorized access to system information when interacting directly with a driver installed by Vijeo Designer or EcoStruxure Machine Expert" }, { "lang": "es", "value": "Se presenta una vulnerabilidad de Restricci\u00f3n Inapropiada de Operaciones dentro de los l\u00edmites de un b\u00fafer de la memoria, que podr\u00eda causar una denegaci\u00f3n de servicio o acceso no autorizado a la informaci\u00f3n del sistema interactuando directamente con un controlador instalado por Vijeo Designer o EcoStruxure Machine Expert" } ], "id": "CVE-2021-22705", "lastModified": "2024-11-21T05:50:29.907", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 4.6, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-05-26T20:15:08.897", "references": [ { "source": "cybersecurity@se.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-02" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-02" } ], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "cybersecurity@se.com", "type": "Primary" } ] }