Vulnerabilites related to mitsubishielectric - fx5-enet\/ip
cve-2023-2062
Vulnerability from cvelistv5
Published
2023-06-02 04:04
Modified
2024-10-31 22:37
Summary
Missing Password Field Masking vulnerability in Mitsubishi Electric Corporation EtherNet/IP configuration tools SW1DNN-EIPCT-BD and SW1DNN-EIPCTFX5-BD allows a remote unauthenticated attacker to know the password for MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP. This vulnerability results in authentication bypass vulnerability, which allows the attacker to access MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP via FTP.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T06:12:20.250Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2023-004.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU92908006"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "EtherNet/IP Configuration tool for RJ71EIP91 SW1DNN-EIPCT-BD",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "Software version \"1.01B\" and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EtherNet/IP Configuration tool for FX5-ENET/IP SW1DNN-EIPCTFX5-BD",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "Software version \"1.01B\" and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Missing Password Field Masking vulnerability in Mitsubishi Electric Corporation EtherNet/IP configuration tools SW1DNN-EIPCT-BD and SW1DNN-EIPCTFX5-BD allows a remote unauthenticated attacker to know the password for MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP. This vulnerability results in authentication bypass vulnerability, which allows the attacker to access MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP via FTP."
            }
          ],
          "value": "Missing Password Field Masking vulnerability in Mitsubishi Electric Corporation EtherNet/IP configuration tools SW1DNN-EIPCT-BD and SW1DNN-EIPCTFX5-BD allows a remote unauthenticated attacker to know the password for MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP. This vulnerability results in authentication bypass vulnerability, which allows the attacker to access MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP via FTP."
        }
      ],
      "impacts": [
        {
          "descriptions": [
            {
              "lang": "en",
              "value": "Information Disclosure"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 6.2,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-549",
              "description": "CWE-549 Missing Password Field Masking",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-31T22:37:13.620Z",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2023-004.pdf"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://jvn.jp/vu/JVNVU92908006"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-157-02"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Information Disclosure vulnerability in EtherNet/IP Configuration tools",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2023-2062",
    "datePublished": "2023-06-02T04:04:28.648Z",
    "dateReserved": "2023-04-14T08:44:07.523Z",
    "dateUpdated": "2024-10-31T22:37:13.620Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-2061
Vulnerability from cvelistv5
Published
2023-06-02 04:03
Modified
2024-08-02 06:12
Summary
Use of Hard-coded Password vulnerability in FTP function on Mitsubishi Electric Corporation MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP allows a remote unauthenticated attacker to obtain a hard-coded password and access to the module via FTP.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T06:12:19.938Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2023-004.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU92908006"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series EtherNet/IP module RJ71EIP91",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Use of Hard-coded Password vulnerability in FTP function on Mitsubishi Electric Corporation MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP allows a remote unauthenticated attacker to obtain a hard-coded password and access to the module via FTP."
            }
          ],
          "value": "Use of Hard-coded Password vulnerability in FTP function on Mitsubishi Electric Corporation MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP allows a remote unauthenticated attacker to obtain a hard-coded password and access to the module via FTP."
        }
      ],
      "impacts": [
        {
          "descriptions": [
            {
              "lang": "en",
              "value": "Authentication Bypass"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 6.2,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-259",
              "description": "CWE-259 Use of Hard-coded Password",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-06-02T04:03:36.665Z",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2023-004.pdf"
        },
        {
          "url": "https://jvn.jp/vu/JVNVU92908006"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Authentication bypass vulnerability in MELSEC iQ-R Series / iQ-F Series EtherNet/IP Modules",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2023-2061",
    "datePublished": "2023-06-02T04:03:36.665Z",
    "dateReserved": "2023-04-14T08:44:04.100Z",
    "dateUpdated": "2024-08-02T06:12:19.938Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-2063
Vulnerability from cvelistv5
Published
2023-06-02 04:05
Modified
2024-08-02 06:12
Summary
Unrestricted Upload of File with Dangerous Type vulnerability in FTP function on Mitsubishi Electric Corporation MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP allows a remote unauthenticated attacker to cause information disclosure, tampering, deletion or destruction via file upload/download. As a result, the attacker may be able to exploit this for further attacks.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T06:12:19.831Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2023-004.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU92908006"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series EtherNet/IP module RJ71EIP91",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Unrestricted Upload of File with Dangerous Type vulnerability in FTP function on Mitsubishi Electric Corporation MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP allows a remote unauthenticated attacker to cause information disclosure, tampering, deletion or destruction via file upload/download. As a result, the attacker may be able to exploit this for further attacks.\u003cbr\u003e"
            }
          ],
          "value": "Unrestricted Upload of File with Dangerous Type vulnerability in FTP function on Mitsubishi Electric Corporation MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP allows a remote unauthenticated attacker to cause information disclosure, tampering, deletion or destruction via file upload/download. As a result, the attacker may be able to exploit this for further attacks.\n"
        }
      ],
      "impacts": [
        {
          "descriptions": [
            {
              "lang": "en",
              "value": "Information Disclosure"
            }
          ]
        },
        {
          "descriptions": [
            {
              "lang": "en",
              "value": "Infomation Tampering"
            }
          ]
        },
        {
          "descriptions": [
            {
              "lang": "en",
              "value": "Information Deletion"
            }
          ]
        },
        {
          "descriptions": [
            {
              "lang": "en",
              "value": "Information Destruction"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-434",
              "description": "CWE-434 Unrestricted Upload of File with Dangerous Type",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-06-02T04:05:38.109Z",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2023-004.pdf"
        },
        {
          "url": "https://jvn.jp/vu/JVNVU92908006"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Information disclosure, tampering, deletion and destruction vulnerability in MELSEC iQ-R Series / iQ-F Series EtherNet/IP Modules",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2023-2063",
    "datePublished": "2023-06-02T04:05:38.109Z",
    "dateReserved": "2023-04-14T08:44:09.737Z",
    "dateUpdated": "2024-08-02T06:12:19.831Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-2060
Vulnerability from cvelistv5
Published
2023-06-02 04:02
Modified
2024-08-02 06:12
Summary
Weak Password Requirements vulnerability in FTP function on Mitsubishi Electric Corporation MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP allows a remote unauthenticated attacker to access to the module via FTP by dictionary attack or password sniffing.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T06:12:19.945Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2023-004.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU92908006"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series EtherNet/IP module RJ71EIP91",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Weak Password Requirements vulnerability in FTP function on Mitsubishi Electric Corporation MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP allows a remote unauthenticated attacker to access to the module via FTP by dictionary attack or password sniffing."
            }
          ],
          "value": "Weak Password Requirements vulnerability in FTP function on Mitsubishi Electric Corporation MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP allows a remote unauthenticated attacker to access to the module via FTP by dictionary attack or password sniffing."
        }
      ],
      "impacts": [
        {
          "descriptions": [
            {
              "lang": "en",
              "value": "Authentication Bypass"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-521",
              "description": "CWE-521 Weak Password Requirements",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-06-02T04:02:32.377Z",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2023-004.pdf"
        },
        {
          "url": "https://jvn.jp/vu/JVNVU92908006"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Authentication bypass vulnerability in MELSEC iQ-R Series / iQ-F Series EtherNet/IP Modules",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2023-2060",
    "datePublished": "2023-06-02T04:02:32.377Z",
    "dateReserved": "2023-04-14T08:43:59.259Z",
    "dateUpdated": "2024-08-02T06:12:19.945Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-0457
Vulnerability from cvelistv5
Published
2023-03-03 04:18
Modified
2024-08-02 05:10
Summary
Plaintext Storage of a Password vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series, MELSEC iQ-R Series, MELSEC-Q Series and MELSEC-L Series allows a remote unauthenticated attacker to disclose plaintext credentials stored in project files and login into FTP server or Web server.
Impacted products
Vendor Product Version
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-32MT/ES Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-64MT/ES Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-80MT/ES Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-32MR/ES Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-64MR/ES Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-80MR/ES Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-32MT/DS Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-64MT/DS Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-80MT/DS Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-32MR/DS Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-64MR/DS Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-80MR/DS Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-32MT/ESS Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-64MT/ESS Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-80MT/ESS Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-32MT/DSS Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-64MT/DSS Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-80MT/DSS Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-32MT/D Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-64MT/D Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-96MT/D Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-32MT/DSS Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-64MT/DSS Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-96MT/DSS Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-32MT/DS-TS Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-32MT/DSS-TS Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-32MR/DS-TS Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-24MT/ES Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-40MT/ES Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-60MT/ES Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-24MR/ES Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-40MR/ES Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-60MR/ES Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-24MT/ESS Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-40MT/ESS Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-60MT/ESS Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-24MT/ES-A Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-40MT/ES-A Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-60MT/ES-A Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-24MR/ES-A Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-40MR/ES-A Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-60MR/ES-A Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-30MT/ES Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-40MT/ES Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-60MT/ES Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-80MT/ES Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-30MR/ES Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-40MR/ES Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-60MR/ES Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-80MR/ES Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-30MT/ESS Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-40MT/ESS Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-60MT/ESS Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-80MT/ESS Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5-ENET Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-F Series FX5-ENET/IP Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-R Series R00CPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-R Series R01CPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-R Series R02CPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-R Series R04CPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-R Series R08CPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-R Series R16CPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-R Series R32CPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-R Series R120CPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-R Series R04ENCPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-R Series R08ENCPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-R Series R16ENCPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-R Series R32ENCPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-R Series R120ENCPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-R Series R08SFCPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-R Series R16SFCPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-R Series R32SFCPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-R Series R120SFCPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-R Series R08PCPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-R Series R16PCPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-R Series R32PCPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-R Series R120PCPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-R Series R08PSFCPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-R Series R16PSFCPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-R Series R32PSFCPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-R Series R120PSFCPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-R Series RJ71EN71 Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC iQ-R Series R12CCPU-V Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC-Q Series Q03UDECPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC-Q Series Q04UDEHCPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC-Q Series Q06UDEHCPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC-Q Series Q10UDEHCPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC-Q Series Q13UDEHCPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC-Q Series Q20UDEHCPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC-Q Series Q26UDEHCPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC-Q Series Q50UDEHCPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC-Q Series Q100UDEHCPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC-Q Series Q03UDVCPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC-Q Series Q04UDVCPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC-Q Series Q06UDVCPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC-Q Series Q13UDVCPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC-Q Series Q26UDVCPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC-Q Series Q04UDPVCPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC-Q Series Q06UDPVCPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC-Q Series Q13UDPVCPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC-Q Series Q26UDPVCPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC-Q Series QJ71E71-100 Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC-L Series L02CPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC-L Series L06CPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC-L Series L26CPU Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC-L Series L02CPU-P Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC-L Series L06CPU-P Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC-L Series L26CPU-P Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC-L Series L26CPU-BT Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC-L Series L26CPU-PBT Version: all versions
Create a notification for this product.
   Mitsubishi Electric Corporation MELSEC-L Series LJ71E71-100 Version: all versions
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T05:10:56.351Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-023_en.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU93891523/index.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-061-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-32MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-64MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-80MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-32MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-64MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-80MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-32MT/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-64MT/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-80MT/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-32MR/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-64MR/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-80MR/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-32MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-64MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-80MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-32MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-64MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-80MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UC-32MT/D",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UC-64MT/D",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UC-96MT/D",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UC-32MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UC-64MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UC-96MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UC-32MT/DS-TS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UC-32MT/DSS-TS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UC-32MR/DS-TS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-24MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-40MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-60MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-24MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-40MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-60MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-24MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-40MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-60MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-24MT/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-40MT/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-60MT/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-24MR/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-40MR/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-60MR/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-30MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-40MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-60MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-80MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-30MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-40MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-60MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-80MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-30MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-40MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-60MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-80MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5-ENET",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5-ENET/IP",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R00CPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R01CPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R02CPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R04CPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R08CPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R16CPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R32CPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R120CPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R04ENCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R08ENCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R16ENCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R32ENCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R120ENCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R08SFCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R16SFCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R32SFCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R120SFCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R08PCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R16PCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R32PCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R120PCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R08PSFCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R16PSFCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R32PSFCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R120PSFCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series RJ71EN71",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R12CCPU-V",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-Q Series Q03UDECPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-Q Series Q04UDEHCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-Q Series Q06UDEHCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-Q Series Q10UDEHCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-Q Series Q13UDEHCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-Q Series Q20UDEHCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-Q Series Q26UDEHCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-Q Series Q50UDEHCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-Q Series Q100UDEHCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-Q Series Q03UDVCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-Q Series Q04UDVCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-Q Series Q06UDVCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-Q Series Q13UDVCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-Q Series Q26UDVCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-Q Series Q04UDPVCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-Q Series Q06UDPVCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-Q Series Q13UDPVCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-Q Series Q26UDPVCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-Q Series QJ71E71-100",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-L Series L02CPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-L Series L06CPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-L Series L26CPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-L Series L02CPU-P",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-L Series L06CPU-P",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-L Series L26CPU-P",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-L Series L26CPU-BT",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-L Series L26CPU-PBT",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-L Series LJ71E71-100",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Plaintext Storage of a Password vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series, MELSEC iQ-R Series, MELSEC-Q Series and MELSEC-L Series allows a remote unauthenticated attacker to disclose plaintext credentials stored in project files and login into FTP server or Web server."
            }
          ],
          "value": "Plaintext Storage of a Password vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series, MELSEC iQ-R Series, MELSEC-Q Series and MELSEC-L Series allows a remote unauthenticated attacker to disclose plaintext credentials stored in project files and login into FTP server or Web server."
        }
      ],
      "impacts": [
        {
          "descriptions": [
            {
              "lang": "en",
              "value": "Information disclosure"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-256",
              "description": "CWE-256 Plaintext Storage of a Password",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-06-21T04:21:45.500Z",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-023_en.pdf"
        },
        {
          "url": "https://jvn.jp/vu/JVNVU93891523/index.html"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-061-01"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Information Disclosure Vulnerability in MELSEC Series",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2023-0457",
    "datePublished": "2023-03-03T04:18:15.787Z",
    "dateReserved": "2023-01-24T08:55:21.468Z",
    "dateUpdated": "2024-08-02T05:10:56.351Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2020-16226
Vulnerability from cvelistv5
Published
2020-10-05 17:19
Modified
2024-09-17 00:25
Severity ?
Summary
Multiple Mitsubishi Electric products are vulnerable to impersonations of a legitimate device by a malicious actor, which may allow an attacker to remotely execute arbitrary commands.
References
Impacted products
Vendor Product Version
Mitsubishi Electric QJ71MES96 Version: all versions
Create a notification for this product.
   Mitsubishi Electric QJ71WS96 Version: all versions
Create a notification for this product.
   Mitsubishi Electric Q06CCPU-V Version: all versions
Create a notification for this product.
   Mitsubishi Electric Q24DHCCPU-V Version: all versions
Create a notification for this product.
   Mitsubishi Electric Q24DHCCPU-VG Version: all versions
Create a notification for this product.
   Mitsubishi Electric R12CCPU-V Version: all versions
Create a notification for this product.
   Mitsubishi Electric RD55UP06-V, Version: all versions
Create a notification for this product.
   Mitsubishi Electric D55UP12-V Version: all versions
Create a notification for this product.
   Mitsubishi Electric RJ71GN11-T2 Version: all versions
Create a notification for this product.
   Mitsubishi Electric RJ71EN71 Version: all versions
Create a notification for this product.
   Mitsubishi Electric QJ71E71-100 Version: all versions
Create a notification for this product.
   Mitsubishi Electric LJ71E71-100 Version: all versions
Create a notification for this product.
   Mitsubishi Electric QJ71MT91 Version: all versions
Create a notification for this product.
   Mitsubishi Electric RD78Gn(n=4,8,16,32,64) Version: all versions
Create a notification for this product.
   Mitsubishi Electric RD78GHV Version: all versions
Create a notification for this product.
   Mitsubishi Electric RD78GHW Version: all versions
Create a notification for this product.
   Mitsubishi Electric NZ2GACP620-60 Version: all versions
Create a notification for this product.
   Mitsubishi Electric NZ2GACP620-300 Version: all versions
Create a notification for this product.
   Mitsubishi Electric NZ2FT-MT Version: all versions
Create a notification for this product.
   Mitsubishi Electric NZ2FT-EIP Version: all versions
Create a notification for this product.
   Mitsubishi Electric Q03UDECPU Version: the first 5 digits of serial number 22081 and prior
Create a notification for this product.
   Mitsubishi Electric QnUDEHCPU(n=04/06/10/13/20/26/50/100) Version: the first 5 digits of serial number 22081 and prior
Create a notification for this product.
   Mitsubishi Electric QnUDVCPU(n=03/04/06/13/26) Version: the first 5 digits of serial number 22031 and prior
Create a notification for this product.
   Mitsubishi Electric QnUDPVCPU(n=04/06/13/2) Version: the first 5 digits of serial number 22031 and prior
Create a notification for this product.
   Mitsubishi Electric LnCPU(-P)(n=02/06/26) Version: the first 5 digits of serial number 22051 and prior
Create a notification for this product.
   Mitsubishi Electric L26CPU-(P)BT Version: the first 5 digits of serial number 22051 and prior
Create a notification for this product.
   Mitsubishi Electric RnCPU(n=00/01/02) Version: unspecified   < Version 18 and prior
Create a notification for this product.
   Mitsubishi Electric RnCPU(n=04/08/16/32/120) Version: unspecified   < Version 50 and prior
Create a notification for this product.
   Mitsubishi Electric RnENCPU(n=04/08/16/32/120) Version: unspecified   < Version 50 and prior
Create a notification for this product.
   Mitsubishi Electric RnSFCPU (n=08/16/32/120) Version: all versions
Create a notification for this product.
   Mitsubishi Electric RnPCPU(n=08/16/32/120) Version: all versions
Create a notification for this product.
   Mitsubishi Electric RnPSFCPU(n=08/16/32/120) Version: all versions
Create a notification for this product.
   Mitsubishi Electric FX5U(C)-**M*/** Version: unspecified   < Serial number 17X**** or later: Version 1.210 and prior
Version: unspecified   < Serial number 179**** and prior: Version 1.070 and prior
Create a notification for this product.
   Mitsubishi Electric FX5UC-32M*/**-TS Version: unspecified   < Version 1.210 and prior
Create a notification for this product.
   Mitsubishi Electric FX5UJ-**M*/** Version: Version 1.000
Create a notification for this product.
   Mitsubishi Electric FX5-ENET Version: all versions
Create a notification for this product.
   Mitsubishi Electric FX5-ENET/IP Version: all versions
Create a notification for this product.
   Mitsubishi Electric FX3U-ENET-ADP Version: all versions
Create a notification for this product.
   Mitsubishi Electric FX3GE-**M*/** Version: all versions
Create a notification for this product.
   Mitsubishi Electric FX3U-ENET Version: all versions
Create a notification for this product.
   Mitsubishi Electric FX3U-ENET-L Version: all versions
Create a notification for this product.
   Mitsubishi Electric FX3U-ENET-P502 Version: all versions
Create a notification for this product.
   Mitsubishi Electric FX5-CCLGN-MS Version: all versions
Create a notification for this product.
   Mitsubishi Electric IU1-1M20-D Version: all versions
Create a notification for this product.
   Mitsubishi Electric LE7-40GU-L Version: all versions
Create a notification for this product.
   Mitsubishi Electric GOT2000 Series GT21 Model Version: all versions
Create a notification for this product.
   Mitsubishi Electric GS Series Version: all versions
Create a notification for this product.
   Mitsubishi Electric GOT1000 Series GT14 Model Version: all versions
Create a notification for this product.
   Mitsubishi Electric GT25-J71GN13-T2 Version: all versions
Create a notification for this product.
   Mitsubishi Electric FR-A800-E Series Version: all versions
Create a notification for this product.
   Mitsubishi Electric FR-F800-E Series Version: all versions
Create a notification for this product.
   Mitsubishi Electric FR-A8NCG Version: Production date August 2020 and prior
Create a notification for this product.
   Mitsubishi Electric FR-E800-EPA Series Version: Production date July 2020 and prior
Create a notification for this product.
   Mitsubishi Electric FR-E800-EPB Series Version: Production date July 2020 and prior
Create a notification for this product.
   Mitsubishi Electric Conveyor Tracking Application Version: APR-nTR3FH all versions
Version: APR-nTR6FH all versions
Version: APR-nTR12FH all versions
Version: APR-nTR20FH(n=1,2) all versions
Create a notification for this product.
   Mitsubishi Electric MR-JE-C Version: all versions
Create a notification for this product.
   Mitsubishi Electric MR-J4-TM Version: all versions
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T13:37:54.189Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-245-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "QJ71MES96",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "QJ71WS96",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "Q06CCPU-V",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "Q24DHCCPU-V",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "Q24DHCCPU-VG",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "R12CCPU-V",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "RD55UP06-V,",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "D55UP12-V",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "RJ71GN11-T2",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "RJ71EN71",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "QJ71E71-100",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "LJ71E71-100",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "QJ71MT91",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "RD78Gn(n=4,8,16,32,64)",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "RD78GHV",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "RD78GHW",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "NZ2GACP620-60",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "NZ2GACP620-300",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "NZ2FT-MT",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "NZ2FT-EIP",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "Q03UDECPU",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "the first 5 digits of serial number 22081 and prior"
            }
          ]
        },
        {
          "product": "QnUDEHCPU(n=04/06/10/13/20/26/50/100)",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "the first 5 digits of serial number 22081 and prior"
            }
          ]
        },
        {
          "product": "QnUDVCPU(n=03/04/06/13/26)",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "the first 5 digits of serial number 22031 and prior"
            }
          ]
        },
        {
          "product": "QnUDPVCPU(n=04/06/13/2)",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "the first 5 digits of serial number 22031 and prior"
            }
          ]
        },
        {
          "product": "LnCPU(-P)(n=02/06/26)",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "the first 5 digits of serial number 22051 and prior"
            }
          ]
        },
        {
          "product": "L26CPU-(P)BT",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "the first 5 digits of serial number 22051 and prior"
            }
          ]
        },
        {
          "product": "RnCPU(n=00/01/02)",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThan": "Version 18 and prior",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "RnCPU(n=04/08/16/32/120)",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThan": "Version 50 and prior",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "RnENCPU(n=04/08/16/32/120)",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThan": "Version 50 and prior",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "RnSFCPU (n=08/16/32/120)",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "RnPCPU(n=08/16/32/120)",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "RnPSFCPU(n=08/16/32/120)",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "FX5U(C)-**M*/**",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThan": "Serial number 17X**** or later: Version 1.210 and prior",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            },
            {
              "lessThan": "Serial number 179**** and prior: Version 1.070 and prior",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "FX5UC-32M*/**-TS",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThan": "Version 1.210 and prior",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "FX5UJ-**M*/**",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Version 1.000"
            }
          ]
        },
        {
          "product": "FX5-ENET",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "FX5-ENET/IP",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "FX3U-ENET-ADP",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "FX3GE-**M*/**",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "FX3U-ENET",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "FX3U-ENET-L",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "FX3U-ENET-P502",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "FX5-CCLGN-MS",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "IU1-1M20-D",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "LE7-40GU-L",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "GOT2000 Series GT21 Model",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "GS Series",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "GOT1000 Series GT14 Model",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "GT25-J71GN13-T2",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "FR-A800-E Series",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "FR-F800-E Series",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "FR-A8NCG",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Production date August 2020 and prior"
            }
          ]
        },
        {
          "product": "FR-E800-EPA Series",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Production date July 2020 and prior"
            }
          ]
        },
        {
          "product": "FR-E800-EPB Series",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Production date July 2020 and prior"
            }
          ]
        },
        {
          "product": "Conveyor Tracking Application",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "APR-nTR3FH all versions"
            },
            {
              "status": "affected",
              "version": "APR-nTR6FH all versions"
            },
            {
              "status": "affected",
              "version": "APR-nTR12FH all versions"
            },
            {
              "status": "affected",
              "version": "APR-nTR20FH(n=1,2) all versions"
            }
          ]
        },
        {
          "product": "MR-JE-C",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "MR-J4-TM",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        }
      ],
      "datePublic": "2020-09-01T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Multiple Mitsubishi Electric products are vulnerable to impersonations of a legitimate device by a malicious actor, which may allow an attacker to remotely execute arbitrary commands."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-342",
              "description": "PREDICTABLE EXACT VALUE FROM PREVIOUS VALUES CWE-342",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-10-05T17:19:17",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-245-01"
        }
      ],
      "source": {
        "advisory": "ICSA-20-245-01",
        "discovery": "UNKNOWN"
      },
      "title": "Mitsubishi Electric Multiple Products",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2020-09-01T16:00:00.000Z",
          "ID": "CVE-2020-16226",
          "STATE": "PUBLIC",
          "TITLE": "Mitsubishi Electric Multiple Products"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "QJ71MES96",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "QJ71WS96",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Q06CCPU-V",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Q24DHCCPU-V",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Q24DHCCPU-VG",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "R12CCPU-V",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "RD55UP06-V,",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "D55UP12-V",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "RJ71GN11-T2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "RJ71EN71",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "QJ71E71-100",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "LJ71E71-100",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "QJ71MT91",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "RD78Gn(n=4,8,16,32,64)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "RD78GHV",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "RD78GHW",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "NZ2GACP620-60",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "NZ2GACP620-300",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "NZ2FT-MT",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "NZ2FT-EIP",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Q03UDECPU",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "the first 5 digits of serial number 22081 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "QnUDEHCPU(n=04/06/10/13/20/26/50/100)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "the first 5 digits of serial number 22081 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "QnUDVCPU(n=03/04/06/13/26)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "the first 5 digits of serial number 22031 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "QnUDPVCPU(n=04/06/13/2)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "the first 5 digits of serial number 22031 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "LnCPU(-P)(n=02/06/26)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "the first 5 digits of serial number 22051 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "L26CPU-(P)BT",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "the first 5 digits of serial number 22051 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "RnCPU(n=00/01/02)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "Version 18 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "RnCPU(n=04/08/16/32/120)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "Version 50 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "RnENCPU(n=04/08/16/32/120)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "Version 50 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "RnSFCPU (n=08/16/32/120)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "RnPCPU(n=08/16/32/120)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "RnPSFCPU(n=08/16/32/120)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FX5U(C)-**M*/**",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "Serial number 17X**** or later: Version 1.210 and prior"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_value": "Serial number 179**** and prior: Version 1.070 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FX5UC-32M*/**-TS",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "Version 1.210 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FX5UJ-**M*/**",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "Version 1.000"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FX5-ENET",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FX5-ENET/IP",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FX3U-ENET-ADP",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FX3GE-**M*/**",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FX3U-ENET",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FX3U-ENET-L",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FX3U-ENET-P502",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FX5-CCLGN-MS",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "IU1-1M20-D",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "LE7-40GU-L",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GOT2000 Series GT21 Model",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GS Series",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GOT1000 Series GT14 Model",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GT25-J71GN13-T2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FR-A800-E Series",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FR-F800-E Series",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FR-A8NCG",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "Production date August 2020 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FR-E800-EPA Series",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "Production date July 2020 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FR-E800-EPB Series",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "Production date July 2020 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Conveyor Tracking Application",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_name": "APR-nTR3FH",
                            "version_value": "all versions"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "APR-nTR6FH",
                            "version_value": "all versions"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "APR-nTR12FH",
                            "version_value": "all versions"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "APR-nTR20FH(n=1,2)",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MR-JE-C",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MR-J4-TM",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Mitsubishi Electric"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Multiple Mitsubishi Electric products are vulnerable to impersonations of a legitimate device by a malicious actor, which may allow an attacker to remotely execute arbitrary commands."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "PREDICTABLE EXACT VALUE FROM PREVIOUS VALUES CWE-342"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-245-01",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-245-01"
            }
          ]
        },
        "source": {
          "advisory": "ICSA-20-245-01",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-16226",
    "datePublished": "2020-10-05T17:19:17.358565Z",
    "dateReserved": "2020-07-31T00:00:00",
    "dateUpdated": "2024-09-17T00:25:38.551Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Vulnerability from fkie_nvd
Published
2023-06-02 05:15
Modified
2024-11-21 07:57
Summary
Weak Password Requirements vulnerability in FTP function on Mitsubishi Electric Corporation MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP allows a remote unauthenticated attacker to access to the module via FTP by dictionary attack or password sniffing.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5-enet\\/ip_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CE006D41-B94B-45A2-B43C-642616811792",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5-enet\\/ip:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EF5786BC-2E60-45A5-AD11-21CCAAFDDAAB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnn-eipct-bd_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "98777F49-8CB3-4546-875F-2664224FB52C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnn-eipct-bd:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8164854B-5BB1-4936-9BC8-CC78838A47D8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rj71eip91_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF8407A6-F78E-40B8-88D1-D8A824E882F0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rj71eip91:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B2B7116-DAC9-4340-A625-93F461E96964",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnn-eipctfx5-bd_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3210B54-8C0E-4A6D-B466-D1FFB3CA5F2A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnn-eipctfx5-bd:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B42CE2D9-B4E1-40AD-803F-48FA7C9B4230",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Weak Password Requirements vulnerability in FTP function on Mitsubishi Electric Corporation MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP allows a remote unauthenticated attacker to access to the module via FTP by dictionary attack or password sniffing."
    }
  ],
  "id": "CVE-2023-2060",
  "lastModified": "2024-11-21T07:57:51.607",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-06-02T05:15:09.563",
  "references": [
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/vu/JVNVU92908006"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2023-004.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/vu/JVNVU92908006"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2023-004.pdf"
    }
  ],
  "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-521"
        }
      ],
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-521"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-06-02 05:15
Modified
2024-11-21 07:57
Summary
Missing Password Field Masking vulnerability in Mitsubishi Electric Corporation EtherNet/IP configuration tools SW1DNN-EIPCT-BD and SW1DNN-EIPCTFX5-BD allows a remote unauthenticated attacker to know the password for MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP. This vulnerability results in authentication bypass vulnerability, which allows the attacker to access MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP via FTP.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5-enet\\/ip_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CE006D41-B94B-45A2-B43C-642616811792",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5-enet\\/ip:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EF5786BC-2E60-45A5-AD11-21CCAAFDDAAB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnn-eipct-bd_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "98777F49-8CB3-4546-875F-2664224FB52C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnn-eipct-bd:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8164854B-5BB1-4936-9BC8-CC78838A47D8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rj71eip91_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF8407A6-F78E-40B8-88D1-D8A824E882F0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rj71eip91:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B2B7116-DAC9-4340-A625-93F461E96964",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnn-eipctfx5-bd_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3210B54-8C0E-4A6D-B466-D1FFB3CA5F2A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnn-eipctfx5-bd:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B42CE2D9-B4E1-40AD-803F-48FA7C9B4230",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Missing Password Field Masking vulnerability in Mitsubishi Electric Corporation EtherNet/IP configuration tools SW1DNN-EIPCT-BD and SW1DNN-EIPCTFX5-BD allows a remote unauthenticated attacker to know the password for MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP. This vulnerability results in authentication bypass vulnerability, which allows the attacker to access MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP via FTP."
    }
  ],
  "id": "CVE-2023-2062",
  "lastModified": "2024-11-21T07:57:51.857",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 6.2,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.5,
        "impactScore": 3.6,
        "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 6.2,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.5,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-06-02T05:15:10.187",
  "references": [
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/vu/JVNVU92908006"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-157-02"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2023-004.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/vu/JVNVU92908006"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2023-004.pdf"
    }
  ],
  "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-549"
        }
      ],
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-668"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-06-02 05:15
Modified
2024-11-21 07:57
Summary
Use of Hard-coded Password vulnerability in FTP function on Mitsubishi Electric Corporation MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP allows a remote unauthenticated attacker to obtain a hard-coded password and access to the module via FTP.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5-enet\\/ip_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CE006D41-B94B-45A2-B43C-642616811792",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5-enet\\/ip:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EF5786BC-2E60-45A5-AD11-21CCAAFDDAAB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnn-eipct-bd_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "98777F49-8CB3-4546-875F-2664224FB52C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnn-eipct-bd:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8164854B-5BB1-4936-9BC8-CC78838A47D8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rj71eip91_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF8407A6-F78E-40B8-88D1-D8A824E882F0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rj71eip91:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B2B7116-DAC9-4340-A625-93F461E96964",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnn-eipctfx5-bd_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3210B54-8C0E-4A6D-B466-D1FFB3CA5F2A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnn-eipctfx5-bd:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B42CE2D9-B4E1-40AD-803F-48FA7C9B4230",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Use of Hard-coded Password vulnerability in FTP function on Mitsubishi Electric Corporation MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP allows a remote unauthenticated attacker to obtain a hard-coded password and access to the module via FTP."
    }
  ],
  "id": "CVE-2023-2061",
  "lastModified": "2024-11-21T07:57:51.733",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 6.2,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.5,
        "impactScore": 3.6,
        "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-06-02T05:15:10.100",
  "references": [
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/vu/JVNVU92908006"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2023-004.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/vu/JVNVU92908006"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2023-004.pdf"
    }
  ],
  "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-259"
        }
      ],
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-798"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2020-10-05 18:15
Modified
2024-11-21 05:06
Severity ?
Summary
Multiple Mitsubishi Electric products are vulnerable to impersonations of a legitimate device by a malicious actor, which may allow an attacker to remotely execute arbitrary commands.
References
Impacted products
Vendor Product Version
mitsubishielectric qj71mes96_firmware *
mitsubishielectric qj71mes96 -
mitsubishielectric qj71ws96_firmware *
mitsubishielectric qj71ws96 -
mitsubishielectric q06ccpu-v_firmware *
mitsubishielectric q06ccpu-v -
mitsubishielectric q24dhccpu-v_firmware *
mitsubishielectric q24dhccpu-v -
mitsubishielectric q24dhccpu-vg_firmware *
mitsubishielectric q24dhccpu-vg -
mitsubishielectric r12ccpu-v_firmware *
mitsubishielectric r12ccpu-v -
mitsubishielectric rd55up06-v_firmware *
mitsubishielectric rd55up06-v -
mitsubishielectric rd55up12-v_firmware *
mitsubishielectric rd55up12-v -
mitsubishielectric rj71gn11-t2_firmware *
mitsubishielectric rj71gn11-t2 -
mitsubishielectric rj71en71_firmware *
mitsubishielectric rj71en71 -
mitsubishielectric qj71e71-100_firmware *
mitsubishielectric qj71e71-100 -
mitsubishielectric lj71e71-100_firmware *
mitsubishielectric lj71e71-100 -
mitsubishielectric qj71mt91_firmware *
mitsubishielectric qj71mt91 -
mitsubishielectric rd78gn\(n\=4\,8\,16\,32\,64\)_firmware *
mitsubishielectric rd78gn\(n\=4\,8\,16\,32\,64\) -
mitsubishielectric rd78ghv_firmware *
mitsubishielectric rd78ghv -
mitsubishielectric rd78ghw_firmware *
mitsubishielectric rd78ghw -
mitsubishielectric nz2gacp620-60_firmware *
mitsubishielectric nz2gacp620-60 -
mitsubishielectric nz2gacp620-300_firmware *
mitsubishielectric nz2gacp620-300 -
mitsubishielectric nz2ft-mt_firmware *
mitsubishielectric nz2ft-mt -
mitsubishielectric nz2ft-eip_firmware *
mitsubishielectric nz2ft-eip -
mitsubishielectric q03udecpu_firmware *
mitsubishielectric q03udecpu -
mitsubishielectric qnudehcpu\(n\=04\/06\/10\/13\/20\/26\/50\/100\)_firmware *
mitsubishielectric qnudehcpu\(n\=04\/06\/10\/13\/20\/26\/50\/100\) -
mitsubishielectric qnudvcpu\(n\=03\/04\/06\/13\/26\)_firmware *
mitsubishielectric qnudvcpu\(n\=03\/04\/06\/13\/26\) -
mitsubishielectric qnudpvcpu\(n\=04\/06\/13\/2\)_firmware *
mitsubishielectric qnudpvcpu\(n\=04\/06\/13\/2\) -
mitsubishielectric lncpu\(-p\)\(n\=02\/06\/26\)_firmware *
mitsubishielectric lncpu\(-p\)\(n\=02\/06\/26\) -
mitsubishielectric l26cpu-\(p\)bt_firmware *
mitsubishielectric l26cpu-\(p\)bt -
mitsubishielectric rncpu\(n\=00\/01\/02\)t_firmware *
mitsubishielectric rncpu\(n\=00\/01\/02\)t -
mitsubishielectric rncpu\(n\=04\/08\/16\/32\/120\)_firmware *
mitsubishielectric rncpu\(n\=04\/08\/16\/32\/120\) -
mitsubishielectric rnencpu\(n\=04\/08\/16\/32\/120\)_firmware *
mitsubishielectric rnencpu\(n\=04\/08\/16\/32\/120\) -
mitsubishielectric rnsfcpu_\(n\=08\/16\/32\/120\)_firmware *
mitsubishielectric rnsfcpu_\(n\=08\/16\/32\/120\) -
mitsubishielectric rnpcpu\(n\=08\/16\/32\/120\)_firmware *
mitsubishielectric rnpcpu\(n\=08\/16\/32\/120\) -
mitsubishielectric rnpsfcpu\(n\=08\/16\/32\/120\)_firmware *
mitsubishielectric rnpsfcpu\(n\=08\/16\/32\/120\) -
mitsubishielectric fx5uc-32mt\/d_firmware 1.210
mitsubishielectric fx5uc-32mt\/d -
mitsubishielectric fx5uc-32mt\/dss_firmware 1.210
mitsubishielectric fx5uc-32mt\/dss -
mitsubishielectric fx5uc-32mt\/ds-ts_firmware 1.210
mitsubishielectric fx5uc-32mt\/ds-ts -
mitsubishielectric fx5uc-32mt\/dss-ts_firmware 1.210
mitsubishielectric fx5uc-32mt\/dss-ts -
mitsubishielectric fx5uj-24mr\/es_firmware 1.000
mitsubishielectric fx5uj-24mr\/es -
mitsubishielectric fx5uc-32mr\/ds-ts_firmware 1.210
mitsubishielectric fx5uc-32mr\/ds-ts -
mitsubishielectric fx5uj-24mt\/es_firmware 1.000
mitsubishielectric fx5uj-24mt\/es -
mitsubishielectric fx5uj-24mt\/ess_firmware 1.000
mitsubishielectric fx5uj-24mt\/ess -
mitsubishielectric fx5uj-40mr\/es_firmware 1.000
mitsubishielectric fx5uj-40mr\/es -
mitsubishielectric fx5uj-40mt\/es_firmware 1.000
mitsubishielectric fx5uj-40mt\/es -
mitsubishielectric fx5uj-40mt\/ess_firmware 1.000
mitsubishielectric fx5uj-40mt\/ess -
mitsubishielectric fx5uj-60mr\/es_firmware 1.000
mitsubishielectric fx5uj-60mr\/es -
mitsubishielectric fx5uj-60mt\/es_firmware 1.000
mitsubishielectric fx5uj-60mt\/es -
mitsubishielectric fx5uj-60mt\/ess_firmware 1.000
mitsubishielectric fx5uj-60mt\/ess -
mitsubishielectric fx5-enet_firmware *
mitsubishielectric fx5-enet -
mitsubishielectric fx5-enet\/ip_firmware *
mitsubishielectric fx5-enet\/ip -
mitsubishielectric fx5-enet-adp_firmware *
mitsubishielectric fx5-enet-adp -
mitsubishielectric fx3g-14mr\/es_firmware *
mitsubishielectric fx3g-14mr\/es -
mitsubishielectric fx3g-14mt\/ess_firmware *
mitsubishielectric fx3g-14mt\/ess -
mitsubishielectric fx3g-14mr\/ds_firmware *
mitsubishielectric fx3g-14mr\/ds -
mitsubishielectric fx3g-14mt\/dss_firmware *
mitsubishielectric fx3g-14mt\/dss -
mitsubishielectric fx3g-24mr\/es_firmware *
mitsubishielectric fx3g-24mr\/es -
mitsubishielectric fx3g-24mt\/ess_firmware *
mitsubishielectric fx3g-24mt\/ess -
mitsubishielectric fx3g-24mr\/ds_firmware *
mitsubishielectric fx3g-24mr\/ds -
mitsubishielectric fx3g-24mt\/dss_firmware *
mitsubishielectric fx3g-24mt\/dss -
mitsubishielectric fx3g-40mr\/es_firmware *
mitsubishielectric fx3g-40mr\/es -
mitsubishielectric fx3g-40mt\/ess_firmware *
mitsubishielectric fx3g-40mt\/ess -
mitsubishielectric fx3g-40mr\/ds_firmware *
mitsubishielectric fx3g-40mr\/ds -
mitsubishielectric fx3g-40mt\/dss_firmware *
mitsubishielectric fx3g-40mt\/dss -
mitsubishielectric fx3g-60mr\/es_firmware *
mitsubishielectric fx3g-60mr\/es -
mitsubishielectric fx3g-60mt\/ess_firmware *
mitsubishielectric fx3g-60mt\/ess -
mitsubishielectric fx3g-60mr\/ds_firmware *
mitsubishielectric fx3g-60mr\/ds -
mitsubishielectric fx3g-60mt\/dss_firmware *
mitsubishielectric fx3g-60mt\/dss -
mitsubishielectric fx3g-24mr\/es_firmware *
mitsubishielectric fx3g-24mr\/es -
mitsubishielectric fx3g-24mt\/ess_firmware *
mitsubishielectric fx3g-24mt\/ess -
mitsubishielectric fx3g-24mr\/ds_firmware *
mitsubishielectric fx3g-24mr\/ds -
mitsubishielectric fx3g-24mt\/dss_firmware *
mitsubishielectric fx3g-24mt\/dss -
mitsubishielectric fx3g-40mr\/es_firmware *
mitsubishielectric fx3g-40mr\/es -
mitsubishielectric fx3g-40mt\/ess_firmware *
mitsubishielectric fx3g-40mt\/ess -
mitsubishielectric fx3g-40mr\/ds_firmware *
mitsubishielectric fx3g-40mr\/ds -
mitsubishielectric fx3g-40mt\/dss_firmware *
mitsubishielectric fx3g-40mt\/dss -
mitsubishielectric fx3g-32_mt\/dss_firmware *
mitsubishielectric fx3g-32_mt\/dss -
mitsubishielectric fx3u-enet_firmware *
mitsubishielectric fx3u-enet -
mitsubishielectric fx3u-enet-l_firmware *
mitsubishielectric fx3u-enet-l -
mitsubishielectric fx3u-enet-p502_firmware *
mitsubishielectric fx3u-enet-p502 -
mitsubishielectric fx5-cclgn-ms_firmware *
mitsubishielectric fx5-cclgn-ms -
mitsubishielectric iu1-1m20-d_firmware *
mitsubishielectric iu1-1m20-d -
mitsubishielectric le7-40gu-l_firmware *
mitsubishielectric le7-40gu-l -
mitsubishielectric got2000_series_gt21_firmware *
mitsubishielectric got2000_series_gt21 -
mitsubishielectric got_simple_series_gs21_firmware *
mitsubishielectric got_simple_series_gs21 -
mitsubishielectric got1000_series_gt14_firmware *
mitsubishielectric got1000_series_gt14 -
mitsubishielectric gt25-j71gn13-t2_firmware *
mitsubishielectric gt25-j71gn13-t2 -
mitsubishielectric fr-a820-e_firmware *
mitsubishielectric fr-a820-e -
mitsubishielectric fr-a840-e_firmware *
mitsubishielectric fr-a840-e -
mitsubishielectric fr-a860-e_firmware *
mitsubishielectric fr-a860-e -
mitsubishielectric fr-a842-e_firmware *
mitsubishielectric fr-a842-e -
mitsubishielectric fr-a862-e_firmware *
mitsubishielectric fr-a862-e -
mitsubishielectric fr-f820-e_firmware *
mitsubishielectric fr-f820-e -
mitsubishielectric fr-f840-e_firmware *
mitsubishielectric fr-f840-e -
mitsubishielectric fr-f860-e_firmware *
mitsubishielectric fr-f860-e -
mitsubishielectric fr-f842-e_firmware *
mitsubishielectric fr-f842-e -
mitsubishielectric fr-f862-e_firmware *
mitsubishielectric fr-f862-e -
mitsubishielectric fr-a8ncge_firmware *
mitsubishielectric fr-a8ncge -
mitsubishielectric fr-e800-epa_firmware *
mitsubishielectric fr-e800-epa -
mitsubishielectric fr-e800-epb_firmware *
mitsubishielectric fr-e800-epb -
mitsubishielectric conveyor_tracking_application_apr-ntr12fh -
mitsubishielectric conveyor_tracking_application_apr-ntr20fh\(n\=1\,2\) -
mitsubishielectric conveyor_tracking_application_apr-ntr3fh *
mitsubishielectric conveyor_tracking_application_apr-ntr6fh -
mitsubishielectric mr-je-c_firmware *
mitsubishielectric mr-je-c -
mitsubishielectric mr-j4-tm_firmware *
mitsubishielectric mr-j4-tm -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:qj71mes96_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3C7DBDF-F467-4310-8B65-EF611692202F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:qj71mes96:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E9566C3-CFB4-4658-AFAE-ADD1B9DA9211",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:qj71ws96_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4AB29EE-605F-4140-A84F-B82E7762D826",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:qj71ws96:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E39BAAFF-FF1F-4279-B501-E0A918CC54CD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:q06ccpu-v_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9ED3CA2D-EE3F-4281-883F-4A7FCB4CEE3B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:q06ccpu-v:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E517BA2F-CF39-49C2-A68E-64A2CE17DBDE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:q24dhccpu-v_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3E848004-A141-4C9F-9A6C-73A3BD7A6082",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:q24dhccpu-v:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "210A2E8A-BF20-43F5-BA07-CB662833DE1D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:q24dhccpu-vg_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D1FC6B1-F265-4565-95A7-1F3F55634C17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:q24dhccpu-vg:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D9DF6F77-EEB5-4CB3-B041-7BA43F16E2E3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:r12ccpu-v_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "56BCED50-FEC2-4F26-81AC-0C3C9BD12C4B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:r12ccpu-v:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B938943-DDD5-43DC-98A3-29D0E6AFBF85",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rd55up06-v_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EF1853A1-8C0D-4EC0-BECC-A89D1CEFDFE5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rd55up06-v:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F1F5EF13-A273-459E-815B-F21C57D44204",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rd55up12-v_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8E5CCD36-42A4-4B7C-B5E1-23F6E4BB1DAE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rd55up12-v:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0ED862A7-87F7-4548-B2AB-2A3DB3ED1482",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rj71gn11-t2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B3F3EDD1-A50F-4581-96D7-9577F9836574",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rj71gn11-t2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A7B5FE39-4540-4A95-ABA8-15F8EA545DE1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rj71en71_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B038D8DD-BE83-4AEB-96DF-FAF9EA630222",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rj71en71:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8BD2CE10-A6DB-4642-8FA8-DD1AFA726EC7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:qj71e71-100_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4BAF2D41-713E-4EA6-A705-57963DBF1309",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:qj71e71-100:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FD1EB30-B1FC-49CC-97D7-739AA5E92E86",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:lj71e71-100_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CFBF46E0-7580-48ED-AB04-490204FBBA33",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:lj71e71-100:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DF312DE0-1882-41A2-A2F6-BA4CB71837E2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:qj71mt91_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1BC6EE26-1644-45F7-8489-B6380FC493F4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:qj71mt91:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58095D28-F44C-4876-9B6F-6D1CFD3D602A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rd78gn\\(n\\=4\\,8\\,16\\,32\\,64\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8B55521-A137-4A7F-839E-1B3DBCB7E313",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rd78gn\\(n\\=4\\,8\\,16\\,32\\,64\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE041A8C-11A7-4FAB-A363-49F429AEF24A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rd78ghv_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A5DCA431-9DA7-48B5-9107-86CA9DAD360E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rd78ghv:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "12E5533D-15A8-471B-899B-FE9F9655EE8F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rd78ghw_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B9722D1-BAB9-4E43-8612-4B6496DD1AF1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rd78ghw:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B5C3119-7579-4623-8513-65A281BDF0D1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:nz2gacp620-60_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B5A3B553-08E8-4415-BDAF-897181D5B11A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:nz2gacp620-60:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFB0F4E4-F634-4D0C-A693-AC48962C320B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:nz2gacp620-300_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E791C3F4-D449-4B3B-B07D-A683D621B6A9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:nz2gacp620-300:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ABDD7EA6-1946-46DB-AD2B-2F778AB11AA3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:nz2ft-mt_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "071EB002-B837-48B0-8276-A8B0AA5D578E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:nz2ft-mt:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "713AE73B-463A-4B2B-8B35-64FB0D53B416",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:nz2ft-eip_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "40F04BC6-17EA-4F6F-BB5B-C87FEE3CB59B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:nz2ft-eip:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D5CF34B6-9CCF-491C-A327-A38D0BAC504D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:q03udecpu_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "37E5D21A-8561-45FE-88E1-725D3488AA22",
              "versionEndIncluding": "22081",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:q03udecpu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "946DA26E-A6B2-46F6-BA81-A92133124823",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:qnudehcpu\\(n\\=04\\/06\\/10\\/13\\/20\\/26\\/50\\/100\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "503A8334-5C68-440E-B76D-5B834557C999",
              "versionEndIncluding": "22081",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:qnudehcpu\\(n\\=04\\/06\\/10\\/13\\/20\\/26\\/50\\/100\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "94A82925-8D77-4914-924A-350CF77857A4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:qnudvcpu\\(n\\=03\\/04\\/06\\/13\\/26\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "57284400-F051-4E3A-B019-B308EF4F4997",
              "versionEndIncluding": "22031",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:qnudvcpu\\(n\\=03\\/04\\/06\\/13\\/26\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "745BC528-D8A3-4393-A267-0A4E2FB81603",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:qnudpvcpu\\(n\\=04\\/06\\/13\\/2\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9EE5B71-EEAB-47E4-BCAB-1E81C40686B5",
              "versionEndIncluding": "22031",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:qnudpvcpu\\(n\\=04\\/06\\/13\\/2\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6136D778-C9AB-49C2-A90C-9281B34308EA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:lncpu\\(-p\\)\\(n\\=02\\/06\\/26\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2ACB71CE-71B7-442C-A44F-B9DF138C45F7",
              "versionEndIncluding": "22051",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:lncpu\\(-p\\)\\(n\\=02\\/06\\/26\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1CC9C7BE-9D93-477D-B560-EAB4367A4844",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:l26cpu-\\(p\\)bt_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9FBAF171-F382-4393-A326-D43D8F8BB55B",
              "versionEndIncluding": "22051",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:l26cpu-\\(p\\)bt:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CE019E69-01F5-4AC8-BE72-48A7B0FD0C56",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rncpu\\(n\\=00\\/01\\/02\\)t_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D83880E-6DBE-4D64-B467-744F89C42743",
              "versionEndIncluding": "18",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rncpu\\(n\\=00\\/01\\/02\\)t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8E83D77-A204-406C-AC54-CB97A66090C8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rncpu\\(n\\=04\\/08\\/16\\/32\\/120\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A4AF8ADC-ED05-43D2-AF6D-868737E4D1A8",
              "versionEndIncluding": "50",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rncpu\\(n\\=04\\/08\\/16\\/32\\/120\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B2EE57C-3023-4071-BE28-8B42BD181EA1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rnencpu\\(n\\=04\\/08\\/16\\/32\\/120\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6937B45E-B23C-4DE1-A926-3529B4154A03",
              "versionEndIncluding": "50",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rnencpu\\(n\\=04\\/08\\/16\\/32\\/120\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "48C947EF-B119-440B-A47A-0B84A0087D30",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rnsfcpu_\\(n\\=08\\/16\\/32\\/120\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F7ABBACF-10F8-4729-8D3A-A9C5BDB961A5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rnsfcpu_\\(n\\=08\\/16\\/32\\/120\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C5CDD376-A0AD-4924-89F1-F04EBCA9C020",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rnpcpu\\(n\\=08\\/16\\/32\\/120\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E575079C-E69B-4A10-86F4-3440F9BAEBCE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rnpcpu\\(n\\=08\\/16\\/32\\/120\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1A5ABD37-C45D-4D7E-A93B-F9EA2544BA9B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rnpsfcpu\\(n\\=08\\/16\\/32\\/120\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B4B6D8B2-6E4F-437D-95A4-A24BFBFF7350",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rnpsfcpu\\(n\\=08\\/16\\/32\\/120\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "586B69F2-7276-437F-A69C-30B26ECB6B18",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uc-32mt\\/d_firmware:1.210:*:*:*:*:*:*:*",
              "matchCriteriaId": "F319764C-436E-4B29-9224-4A9BFAB21A7B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uc-32mt\\/d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EBBFA917-5DCF-4B0C-8C32-AC384FB880AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uc-32mt\\/dss_firmware:1.210:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F895CD0-E081-49AB-84F9-B5F7C60921A5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uc-32mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2CFE160B-32CC-4529-AD35-7467A32B609E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uc-32mt\\/ds-ts_firmware:1.210:*:*:*:*:*:*:*",
              "matchCriteriaId": "616147FF-B8C0-45DA-B398-B0C15C44BAAE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uc-32mt\\/ds-ts:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C4B64FFA-59CE-46E9-B240-F083B332BFD1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uc-32mt\\/dss-ts_firmware:1.210:*:*:*:*:*:*:*",
              "matchCriteriaId": "BD5D4DAB-0262-4D99-8164-1BF5FC36B8B9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uc-32mt\\/dss-ts:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2122A970-5A7D-40A6-BB97-622B695713ED",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uj-24mr\\/es_firmware:1.000:*:*:*:*:*:*:*",
              "matchCriteriaId": "BBE714C4-7121-43BD-894B-274F25F01BF6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uj-24mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F4BA009-4F0A-427C-9D4A-F8A128F5F8C9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uc-32mr\\/ds-ts_firmware:1.210:*:*:*:*:*:*:*",
              "matchCriteriaId": "B7A24D5B-FE5C-4263-A313-0EE0A6B13E41",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uc-32mr\\/ds-ts:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6319D639-CC7B-414E-9DCB-F9D427E8FEF2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uj-24mt\\/es_firmware:1.000:*:*:*:*:*:*:*",
              "matchCriteriaId": "78F21B67-1550-4575-A6ED-342903CDB8D8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uj-24mt\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2B284B91-7571-4614-A721-676D1972E2D0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uj-24mt\\/ess_firmware:1.000:*:*:*:*:*:*:*",
              "matchCriteriaId": "653A0628-9267-4C71-AB2C-D89107171D37",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uj-24mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7D8A69D9-DE42-4953-AD81-40EF7A003823",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uj-40mr\\/es_firmware:1.000:*:*:*:*:*:*:*",
              "matchCriteriaId": "8A5F3391-4B93-442F-857E-2B8717E93360",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uj-40mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3B0AA6C3-68CC-454B-A959-707BB20F4E07",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uj-40mt\\/es_firmware:1.000:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C0617ED-28FF-4D7A-B246-F23292699021",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uj-40mt\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8ED5C2F9-C203-40FD-B15C-F91A68FA0DCC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uj-40mt\\/ess_firmware:1.000:*:*:*:*:*:*:*",
              "matchCriteriaId": "1A895C09-2DD4-451F-85A2-A77AE1CA36EE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uj-40mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1A38E527-6290-49AE-885A-21C4FC77EE96",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uj-60mr\\/es_firmware:1.000:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A4B25D0-D814-42F5-A91A-A7DFF9D6E1ED",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uj-60mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8CAF8ED8-B265-4FC5-91AE-CFA4C282E27F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uj-60mt\\/es_firmware:1.000:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C56BC76-12CB-4B1C-A3D1-004DD311110B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uj-60mt\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F5B2760-4E56-4FAA-A723-BB7CC28FAFD2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uj-60mt\\/ess_firmware:1.000:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9705681-362F-4F8E-BC42-884A58C3A042",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uj-60mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7625B11E-0A91-46D2-8952-AC0BA956D7A8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5-enet_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B1AC602-30AB-461B-A2BF-5310A33C36F0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5-enet:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1050809B-A058-451E-A62B-2E1707B3887E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5-enet\\/ip_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F30B0C7E-D11C-4BD8-A864-E6614DC79B0C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5-enet\\/ip:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EF5786BC-2E60-45A5-AD11-21CCAAFDDAAB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5-enet-adp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "86E3E631-A5CB-48EF-ACDF-5D936E20E517",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5-enet-adp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A5DA247C-6A4B-4813-BABE-9420919C69EE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-14mr\\/es_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD5F9558-9BE3-4798-8676-0D547240FF8C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-14mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7FDA7E6C-BFBF-4D78-8552-B2B3E6D9987B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-14mt\\/ess_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4F009EDE-0541-4E03-964D-8729DFEC2D4B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-14mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F172545-1962-4611-AF12-C626B0F765FA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-14mr\\/ds_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9CE77F12-BB13-4E48-B047-4725B89544FB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-14mr\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5766FC7F-312E-466E-9D1D-2C3D834A2B19",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-14mt\\/dss_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0E250D61-D30E-4902-9A3E-C964E3972998",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-14mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8BC58D73-605B-4656-A93F-015178A11776",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-24mr\\/es_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E7E0F199-6BF9-469E-8531-F5855F4CAC0B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-24mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A13FA80E-2FCE-43EE-A5F9-01847762DE05",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-24mt\\/ess_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "71C5D511-C2FB-48D6-9546-D20C8320098F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-24mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6709317-170A-4146-8D34-8A36BB46CAB8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-24mr\\/ds_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C46851F9-1EE9-409A-8651-87B3A37F2C8C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-24mr\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FA061AF-EC9E-4490-98B0-4397271B6AFD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-24mt\\/dss_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "79D96213-DF83-4985-BB51-B4ED181B338A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-24mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E1374CFE-25E0-4357-B880-9C52BEE2219C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-40mr\\/es_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "ED616F78-DAAD-4F67-BEBE-3A14D6002650",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-40mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4EEA4C4A-0191-4A2C-B56F-E70475910A03",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-40mt\\/ess_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5940C5A4-254F-4BBC-A65F-A7B07B61B1C1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-40mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B69421D2-A453-43A8-A8D8-5E0B73F7B24A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-40mr\\/ds_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "19D5F69E-3AB7-434A-9476-11A2D5C4C54C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-40mr\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0BBBBCC7-AC22-49C0-B0C0-8D89E633AB74",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-40mt\\/dss_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "506ACCE1-28D0-4983-89F2-DC969D6C5EC8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-40mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "24E0AE74-DF57-4461-9A91-11F31459EC68",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-60mr\\/es_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7D2DA26-04D4-41AC-A00B-EE87780235B4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-60mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5CBC7773-96DA-433A-ABB8-845B19168EBF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-60mt\\/ess_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "50FCB926-E9C4-49F1-B657-F7E009EEE307",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-60mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "010DBD73-40FF-4353-9D11-CE81C4D14EDB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-60mr\\/ds_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3E6CECFB-40F8-4B99-AF07-1FE874B7565C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-60mr\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DB590D55-DA7F-4543-99AA-1A1979F73E69",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-60mt\\/dss_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F7A4438-C9CB-46BB-B1ED-FE6069497A52",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-60mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B69A0E1-E9FA-4C5C-810F-8D3CEC959C20",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-24mr\\/es_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E7E0F199-6BF9-469E-8531-F5855F4CAC0B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-24mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A13FA80E-2FCE-43EE-A5F9-01847762DE05",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-24mt\\/ess_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "71C5D511-C2FB-48D6-9546-D20C8320098F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-24mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6709317-170A-4146-8D34-8A36BB46CAB8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-24mr\\/ds_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C46851F9-1EE9-409A-8651-87B3A37F2C8C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-24mr\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FA061AF-EC9E-4490-98B0-4397271B6AFD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-24mt\\/dss_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "79D96213-DF83-4985-BB51-B4ED181B338A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-24mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E1374CFE-25E0-4357-B880-9C52BEE2219C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-40mr\\/es_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "ED616F78-DAAD-4F67-BEBE-3A14D6002650",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-40mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4EEA4C4A-0191-4A2C-B56F-E70475910A03",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-40mt\\/ess_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5940C5A4-254F-4BBC-A65F-A7B07B61B1C1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-40mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B69421D2-A453-43A8-A8D8-5E0B73F7B24A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-40mr\\/ds_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "19D5F69E-3AB7-434A-9476-11A2D5C4C54C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-40mr\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0BBBBCC7-AC22-49C0-B0C0-8D89E633AB74",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-40mt\\/dss_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "506ACCE1-28D0-4983-89F2-DC969D6C5EC8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-40mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "24E0AE74-DF57-4461-9A91-11F31459EC68",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-32_mt\\/dss_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "43F233A3-B233-4112-93AA-6EA6638CBB77",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-32_mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "16193E36-7987-45EB-AFBE-AFB360043E67",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-enet_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "686B0F97-14C8-48A6-A25F-DF3BC6A0DA07",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-enet:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D1644E1-F748-46A3-8E09-FF5D53FD046F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-enet-l_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A00A164-30D7-45BF-8CB4-00F18569F488",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-enet-l:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C8ACC832-E1EC-46DA-A2D1-CF1A3791A885",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-enet-p502_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0044A99C-4DAD-4593-B329-C3FFE706F8A8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-enet-p502:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "69BA96DC-C462-4286-AE0E-32D141017E7F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5-cclgn-ms_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "671454B2-0474-479F-9F1E-EFCFAC01882E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5-cclgn-ms:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0EE1B348-9F41-40EC-B1FC-D5919F332815",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:iu1-1m20-d_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "714615F1-05A9-4D62-8671-F76CD1380C5A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:iu1-1m20-d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "680B7B83-9F76-4C1F-B87A-F7049A0C46E4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:le7-40gu-l_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0E4FD707-55B1-4A9C-9528-694C1008316B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:le7-40gu-l:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "41477864-1A55-4547-936A-29D6504F0D3A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:got2000_series_gt21_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "16EAF851-CD95-4DD7-9BA0-FBBE90F7339E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:got2000_series_gt21:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0873DFF7-9627-482D-A4A9-72F8E26ACBB0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:got_simple_series_gs21_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F5BF7B0-75CE-481B-88E3-248D47CC19F2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:got_simple_series_gs21:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4D30700D-F1DC-46B1-8785-7E24721264D5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:got1000_series_gt14_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6D68C2E9-3D0A-466B-9476-BE8110EC27E4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:got1000_series_gt14:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3BD1AB4-3A3D-46CD-B613-3E3613AAA273",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:gt25-j71gn13-t2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "44078605-B592-48CC-9F91-F1B745212D78",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:gt25-j71gn13-t2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BDCE2B83-0CBA-447A-8616-780301853AC0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fr-a820-e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A70F1DC9-4930-4A99-BAC7-20F391693641",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fr-a820-e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "64F6D4E4-CFC1-4CD4-92B9-738A062612D5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fr-a840-e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "689C466A-5CA6-4413-8BD6-CCFDBABC006A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fr-a840-e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CD00D598-4BEA-4E9B-9558-E80E22683C2C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fr-a860-e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8AC34BC7-C4E4-4D3B-BAD8-8A77F44AF205",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fr-a860-e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "75275274-2442-4372-B0DD-8AB50ABF08D0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fr-a842-e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D3F579C-C934-4589-90C2-FA1132104726",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fr-a842-e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1615F6C9-3C1E-47F0-9B61-607DCBAE7B50",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fr-a862-e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE896C56-DBD2-4050-9AB0-757F52FE0DBA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fr-a862-e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "08BBF6C1-F3DC-4E07-91A8-82D99BCE7E68",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fr-f820-e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3B923961-A068-4BE4-9C4C-D4F05A8E4A76",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fr-f820-e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ECD15A99-5F0A-49B7-82E4-59B1F8ADD94F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fr-f840-e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B451C55F-DCCC-4C26-BB79-CDBFB9261B9A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fr-f840-e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0CB7232B-97CB-4820-A418-2CFEF95CED04",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fr-f860-e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2735CEBA-9D80-4068-80D4-C5E2B46EB20E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fr-f860-e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2DDDBB50-1EAF-47E1-9DF0-9BA9433F3D47",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fr-f842-e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0FDBDB8D-4019-462E-9D5D-FE5BB57B2F13",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fr-f842-e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BAE513C7-3A83-4B34-A986-016F0AD5216C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fr-f862-e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CFE7D90D-4E2D-4E62-83ED-CEEC9BC58378",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fr-f862-e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "287546A0-141B-4A76-9B04-6914FF31B1A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fr-a8ncge_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F6DD95FF-BA97-45E9-86E5-A1ED73395759",
              "versionEndIncluding": "2020-08",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fr-a8ncge:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "99159924-7D0D-4E0D-A212-1B997A58B791",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fr-e800-epa_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DD834CCD-0D6A-4BA7-8CF1-CE3F358D80DD",
              "versionEndIncluding": "2020-07",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fr-e800-epa:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A3D9C957-5A2F-46EC-B82C-6C0A36EB4A3F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fr-e800-epb_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "753A00F4-4E1C-400D-969C-CB187DE76467",
              "versionEndIncluding": "2020-07",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fr-e800-epb:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A448590A-35B3-4DB5-AEE6-5EBAE325920F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:conveyor_tracking_application_apr-ntr12fh:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1A6D0905-EEF6-4386-BE37-C138A722D04E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:conveyor_tracking_application_apr-ntr20fh\\(n\\=1\\,2\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F0AF6F96-A8F3-4F1C-8BF6-BFADE4ECC872",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:conveyor_tracking_application_apr-ntr3fh:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D72D7D59-109B-4DD5-A59F-2D93D97FD69A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:conveyor_tracking_application_apr-ntr6fh:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EF939B93-2A02-4879-943E-29FB45173F1A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:mr-je-c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "449AF664-6DF7-46D5-8508-CA59D7BD9661",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:mr-je-c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C350628-57BA-4E37-A15D-0B19FBE423AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:mr-j4-tm_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C702434-90C9-47B2-B9EF-F9AFD847D8D2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:mr-j4-tm:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "98B10997-62CF-4512-ABB2-A679E77245AD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Multiple Mitsubishi Electric products are vulnerable to impersonations of a legitimate device by a malicious actor, which may allow an attacker to remotely execute arbitrary commands."
    },
    {
      "lang": "es",
      "value": "M\u00faltiples productos de Mitsubishi Electric, son vulnerables a suplantaciones de un dispositivo leg\u00edtimo por parte de un actor malicioso, lo que puede permitir a un atacante ejecutar comandos arbitrarios remotamente"
    }
  ],
  "id": "CVE-2020-16226",
  "lastModified": "2024-11-21T05:06:58.517",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2020-10-05T18:15:13.133",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-245-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-245-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-342"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-03-03 05:15
Modified
2024-11-21 07:37
Summary
Plaintext Storage of a Password vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series, MELSEC iQ-R Series, MELSEC-Q Series and MELSEC-L Series allows a remote unauthenticated attacker to disclose plaintext credentials stored in project files and login into FTP server or Web server.
Impacted products
Vendor Product Version
mitsubishielectric fx5uc-32mr\/ds-ts_firmware *
mitsubishielectric fx5uc-32mr\/ds-ts -
mitsubishielectric fx5uc-32mt\/d_firmware *
mitsubishielectric fx5uc-32mt\/d -
mitsubishielectric fx5uc-32mt\/dss_firmware *
mitsubishielectric fx5uc-32mt\/dss -
mitsubishielectric fx5uc-32mt\/dss-ts_firmware *
mitsubishielectric fx5uc-32mt\/dss-ts -
mitsubishielectric fx5uc-32mt\/ds-ts_firmware *
mitsubishielectric fx5uc-32mt\/ds-ts -
mitsubishielectric fx5uc-64mt\/d_firmware *
mitsubishielectric fx5uc-64mt\/d -
mitsubishielectric fx5uc-64mt\/dss_firmware *
mitsubishielectric fx5uc-64mt\/dss -
mitsubishielectric fx5uc-96mt\/d_firmware *
mitsubishielectric fx5uc-96mt\/d -
mitsubishielectric fx5uc-96mt\/dss_firmware *
mitsubishielectric fx5uc-96mt\/dss -
mitsubishielectric fx5uj-24mr\/es_firmware *
mitsubishielectric fx5uj-24mr\/es -
mitsubishielectric fx5uj-24mr\/es-a_firmware *
mitsubishielectric fx5uj-24mr\/es-a -
mitsubishielectric fx5uj-24mt\/es_firmware *
mitsubishielectric fx5uj-24mt\/es -
mitsubishielectric fx5uj-24mt\/es-a_firmware *
mitsubishielectric fx5uj-24mt\/es-a -
mitsubishielectric fx5uj-24mt\/ess_firmware *
mitsubishielectric fx5uj-24mt\/ess -
mitsubishielectric fx5uj-40mr\/es_firmware *
mitsubishielectric fx5uj-40mr\/es -
mitsubishielectric fx5uj-40mr\/es-a_firmware *
mitsubishielectric fx5uj-40mr\/es-a -
mitsubishielectric fx5uj-40mt\/es_firmware *
mitsubishielectric fx5uj-40mt\/es -
mitsubishielectric fx5uj-40mt\/es-a_firmware *
mitsubishielectric fx5uj-40mt\/es-a -
mitsubishielectric fx5uj-40mt\/ess_firmware *
mitsubishielectric fx5uj-40mt\/ess -
mitsubishielectric fx5uj-60mr\/es_firmware *
mitsubishielectric fx5uj-60mr\/es -
mitsubishielectric fx5uj-60mr\/es-a_firmware *
mitsubishielectric fx5uj-60mr\/es-a -
mitsubishielectric fx5uj-60mt\/es_firmware *
mitsubishielectric fx5uj-60mt\/es -
mitsubishielectric fx5uj-60mt\/es-a_firmware *
mitsubishielectric fx5uj-60mt\/es-a -
mitsubishielectric fx5uj-60mt\/ess_firmware *
mitsubishielectric fx5uj-60mt\/ess -
mitsubishielectric fx5s-30mr\/es_firmware *
mitsubishielectric fx5s-30mr\/es -
mitsubishielectric fx5s-30mt\/es_firmware *
mitsubishielectric fx5s-30mt\/es -
mitsubishielectric fx5s-30mt\/ess_firmware *
mitsubishielectric fx5s-30mt\/ess -
mitsubishielectric fx5s-40mr\/es_firmware *
mitsubishielectric fx5s-40mr\/es -
mitsubishielectric fx5s-40mt\/es_firmware *
mitsubishielectric fx5s-40mt\/es -
mitsubishielectric fx5s-40mt\/ess_firmware *
mitsubishielectric fx5s-40mt\/ess -
mitsubishielectric fx5s-60mr\/es_firmware *
mitsubishielectric fx5s-60mr\/es -
mitsubishielectric fx5s-60mt\/es_firmware *
mitsubishielectric fx5s-60mt\/es -
mitsubishielectric fx5s-60mt\/ess_firmware *
mitsubishielectric fx5s-60mt\/ess -
mitsubishielectric fx5s-80mr\/es_firmware *
mitsubishielectric fx5s-80mr\/es -
mitsubishielectric fx5s-80mt\/es_firmware *
mitsubishielectric fx5s-80mt\/es -
mitsubishielectric fx5s-80mt\/ess_firmware *
mitsubishielectric fx5s-80mt\/ess -
mitsubishielectric fx5-enet_firmware -
mitsubishielectric fx5-enet -
mitsubishielectric fx5-enet\/ip_firmware -
mitsubishielectric fx5-enet\/ip -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uc-32mr\\/ds-ts_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6CDE5DB8-A6A9-4B56-9D7E-D10A63931B32",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uc-32mr\\/ds-ts:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6319D639-CC7B-414E-9DCB-F9D427E8FEF2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uc-32mt\\/d_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "08A2C6F6-B0F6-49A0-AE67-E21F9DBA427C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uc-32mt\\/d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EBBFA917-5DCF-4B0C-8C32-AC384FB880AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uc-32mt\\/dss_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F0E2560F-DC94-4262-94FB-4A08E1569F3B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uc-32mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2CFE160B-32CC-4529-AD35-7467A32B609E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uc-32mt\\/dss-ts_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F382C88-C839-4E83-BAC0-79A7FA32A196",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uc-32mt\\/dss-ts:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2122A970-5A7D-40A6-BB97-622B695713ED",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uc-32mt\\/ds-ts_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0F5077F2-720D-469F-B5B1-7DA41882C5D2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uc-32mt\\/ds-ts:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C4B64FFA-59CE-46E9-B240-F083B332BFD1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uc-64mt\\/d_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E2433A69-CE8D-4BF1-8C43-9B89CCB2BED8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uc-64mt\\/d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "49F19AFE-8A0C-4F21-AE83-5DE3040917C4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uc-64mt\\/dss_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C700E9DB-1BA4-4081-9689-EC824DFB87EB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uc-64mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EDE9CE57-6C80-4547-8476-55E5CA4BFCE7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uc-96mt\\/d_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "33803BBE-470E-46C3-9682-5E5C40094A9B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uc-96mt\\/d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5233D432-3102-421D-B4F5-66469C28DF3B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uc-96mt\\/dss_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "53C0D393-A809-473E-A635-6E3ED0CF3B3B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uc-96mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "491D865E-3C0A-4ED7-AEAF-A0D69D832DBA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uj-24mr\\/es_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "075AEA8E-DD81-43FF-B896-732CCF073C99",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uj-24mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F4BA009-4F0A-427C-9D4A-F8A128F5F8C9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uj-24mr\\/es-a_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "93BFC0D1-8500-4E66-8B1E-4A7B304DD1AB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uj-24mr\\/es-a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "330C0F0C-CDD8-4F69-AC97-4FCE2B18FDEB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uj-24mt\\/es_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4897811B-EAA0-48DA-B91E-E518395ED649",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uj-24mt\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2B284B91-7571-4614-A721-676D1972E2D0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uj-24mt\\/es-a_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F94305D1-C506-4634-BCE2-CF0341C8144E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uj-24mt\\/es-a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "345CD57D-EC2D-4A9E-B4A3-9E32535ECC23",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uj-24mt\\/ess_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2EA335D-33BD-4EF1-A089-849104BC49AB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uj-24mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7D8A69D9-DE42-4953-AD81-40EF7A003823",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uj-40mr\\/es_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5CCEC3B-9F39-4E49-8122-B30B826D48EA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uj-40mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3B0AA6C3-68CC-454B-A959-707BB20F4E07",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uj-40mr\\/es-a_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A8C6E64-974E-4BC6-BC23-1DE74719ACA5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uj-40mr\\/es-a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "02EDA888-358E-4207-A887-C376A13C6865",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uj-40mt\\/es_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0956C2A7-F39B-45C3-8264-2D5F82CAF744",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uj-40mt\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8ED5C2F9-C203-40FD-B15C-F91A68FA0DCC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uj-40mt\\/es-a_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CEC327F2-031C-4B6D-A111-761A481C2D3D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uj-40mt\\/es-a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2F93585F-E50B-4EFB-AD36-538D2780C9F7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uj-40mt\\/ess_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "23DECD15-2856-46D7-B433-24CD755934FB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uj-40mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1A38E527-6290-49AE-885A-21C4FC77EE96",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uj-60mr\\/es_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5C4041A9-B455-4008-86BB-EA79364EA0F5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uj-60mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8CAF8ED8-B265-4FC5-91AE-CFA4C282E27F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uj-60mr\\/es-a_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DC4DDC7E-49E5-4466-9A12-66CAF434DF8D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uj-60mr\\/es-a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E9C2820-AE1B-46CD-B89E-F7DB9956F821",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uj-60mt\\/es_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "653C938B-3F64-4FA8-8C6E-F8EF0E16C770",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uj-60mt\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F5B2760-4E56-4FAA-A723-BB7CC28FAFD2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uj-60mt\\/es-a_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A2960A78-6608-465A-91CB-CF8665348BF3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uj-60mt\\/es-a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "427E4718-7C06-4E32-937B-F7C1DDCC1417",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uj-60mt\\/ess_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E2265DA-D870-4DE5-9252-F9A826342C3B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uj-60mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7625B11E-0A91-46D2-8952-AC0BA956D7A8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5s-30mr\\/es_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DA22AAC-C754-4A64-8701-81C989CC14B2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5s-30mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9399ED33-EE3C-4414-8A64-302818CCB800",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5s-30mt\\/es_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8AC33A08-4B82-4049-8025-2CA40AF6584E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5s-30mt\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "220F7702-E3A5-423D-B8E9-497E6D13AC96",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5s-30mt\\/ess_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "428F794E-83B6-4C81-A367-4154A632F655",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5s-30mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D96E9F3-772A-4409-BD58-1B11849B5B0C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5s-40mr\\/es_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8FCDF4D0-26AF-4E40-8312-FA35D232878E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5s-40mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "65FF4238-35D3-47D6-B525-25BCF3A2387D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5s-40mt\\/es_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9D4254D-8618-4365-8675-BD51E4D3AB78",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5s-40mt\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8420F36A-8929-412F-B76C-D5EC0C02DE85",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5s-40mt\\/ess_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "16DDB35E-0068-41A3-8BC9-32175A59ADEB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5s-40mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B8A9BFDA-4780-4747-8B55-B111C0502BFA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5s-60mr\\/es_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "67832CC5-B673-4723-ABC8-68066D1FE651",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5s-60mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "452DE6F2-39A0-401C-905B-BA3D98DAE4B0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5s-60mt\\/es_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D52315EF-9BF0-46A0-A334-AB7B38A79A3F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5s-60mt\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1A1CB7DA-A3E4-4ED3-8C89-6D191539C697",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5s-60mt\\/ess_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B538CF8A-E8FD-475D-B074-E797507DFEDB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5s-60mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B5589A7F-1159-4CD1-86FB-1392E8D17F3F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5s-80mr\\/es_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6D63DFB9-208E-4977-B34C-D3B41A8495B2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5s-80mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A92C4E6-6D6B-4A68-9920-CD37E1E49B31",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5s-80mt\\/es_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "04BD0DA8-4CA8-4CFC-8C2C-EF323BE76D65",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5s-80mt\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A71E25F0-29AE-4924-9A32-BF597C58034F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5s-80mt\\/ess_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D2D4BF30-6403-4D3C-A4C5-F3E0C1A5F839",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5s-80mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FDE63C5E-36DC-4650-AF9B-C324FDA475A8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5-enet_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B30BB01B-45FB-43D1-B24E-530978EBF3EB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5-enet:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1050809B-A058-451E-A62B-2E1707B3887E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5-enet\\/ip_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CE006D41-B94B-45A2-B43C-642616811792",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5-enet\\/ip:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EF5786BC-2E60-45A5-AD11-21CCAAFDDAAB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Plaintext Storage of a Password vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series, MELSEC iQ-R Series, MELSEC-Q Series and MELSEC-L Series allows a remote unauthenticated attacker to disclose plaintext credentials stored in project files and login into FTP server or Web server."
    }
  ],
  "id": "CVE-2023-0457",
  "lastModified": "2024-11-21T07:37:12.830",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-03-03T05:15:12.037",
  "references": [
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/vu/JVNVU93891523/index.html"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Mitigation",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-061-01"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-023_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/vu/JVNVU93891523/index.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-061-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-023_en.pdf"
    }
  ],
  "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-256"
        }
      ],
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-522"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-06-02 05:15
Modified
2024-11-21 07:57
Summary
Unrestricted Upload of File with Dangerous Type vulnerability in FTP function on Mitsubishi Electric Corporation MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP allows a remote unauthenticated attacker to cause information disclosure, tampering, deletion or destruction via file upload/download. As a result, the attacker may be able to exploit this for further attacks.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5-enet\\/ip_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CE006D41-B94B-45A2-B43C-642616811792",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5-enet\\/ip:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EF5786BC-2E60-45A5-AD11-21CCAAFDDAAB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnn-eipct-bd_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "98777F49-8CB3-4546-875F-2664224FB52C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnn-eipct-bd:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8164854B-5BB1-4936-9BC8-CC78838A47D8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rj71eip91_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF8407A6-F78E-40B8-88D1-D8A824E882F0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rj71eip91:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B2B7116-DAC9-4340-A625-93F461E96964",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnn-eipctfx5-bd_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3210B54-8C0E-4A6D-B466-D1FFB3CA5F2A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnn-eipctfx5-bd:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B42CE2D9-B4E1-40AD-803F-48FA7C9B4230",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Unrestricted Upload of File with Dangerous Type vulnerability in FTP function on Mitsubishi Electric Corporation MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP allows a remote unauthenticated attacker to cause information disclosure, tampering, deletion or destruction via file upload/download. As a result, the attacker may be able to exploit this for further attacks.\n"
    }
  ],
  "id": "CVE-2023-2063",
  "lastModified": "2024-11-21T07:57:51.990",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "LOW",
          "baseScore": 6.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.4,
        "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "LOW",
          "baseScore": 7.3,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.4,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-06-02T05:15:10.263",
  "references": [
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/vu/JVNVU92908006"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2023-004.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/vu/JVNVU92908006"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2023-004.pdf"
    }
  ],
  "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-434"
        }
      ],
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-434"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

var-202010-0395
Vulnerability from variot

Multiple Mitsubishi Electric products are vulnerable to impersonations of a legitimate device by a malicious actor, which may allow an attacker to remotely execute arbitrary commands. of multiple Mitsubishi Electric products TCP A vulnerability in session management exists in the protocol stack. This vulnerability information is provided by the developer for the purpose of dissemination to product users. Authentication is not required to exploit this vulnerability.The specific flaw exists within the processing of ACK packets. When generating ACK packets, the application uses a predictable sequence number. An attacker can leverage this vulnerability to execute arbitrary code in the context of the current process. Mitsubishi Electric gt14 model是日本三菱电机(Mitsubishi Electric)公司的一个用于工业生产过程中提供人机交互界面的设备. Mitsubishi Electric 多个产品存在命令执行漏洞,该漏洞允许攻击者冒充合法设备,从而使攻击者能够远程执行任意命令。以下产品和版本受到影响:QJ71MES96 all versions,QJ71WS96 all versions,Q06CCPU-V all versions,Q24DHCCPU-V all versions,Q24DHCCPU-VG all versions,R12CCPU-V Version 13 and prior,RD55UP06-V Version 09 and prior,RD55UP12-V Version 01,RJ71GN11-T2 Version 11 and prior,RJ71EN71 all versions,QJ71E71-100 all versions,LJ71E71-100 all versions,QJ71MT91 all versions,RD78Gn(n=4,8,16,32,64) all versions,RD78GHV all versions,RD78GHW all versions,NZ2GACP620-60 all versions,NZ2GACP620-300 all versions,NZ2FT-MT all versions,NZ2FT-EIP all versions,Q03UDECPU the first 5 digits of serial number 22081 and prior,QnUDEHCPU(n=04/06/10/13/20/26/50/100) the first 5 digits of serial number 22081 and prior,QnUDVCPU(n=03/04/06/13/26) the first 5 digits of serial number 22031 and prior,QnUDPVCPU(n=04/06/13/26) the first 5 digits of serial number 22031 and prior,LnCPU(-P)(n=02/06/26) the first 5 digits of serial number 22051 and prior,L26CPU-(P)BT the first 5 digits of serial number 22051 and prior,RnCPU(n=00/01/02) Version 18 and prior,RnCPU(n=04/08/16/32/120) Version 50 and prior,RnENCPU(n=04/08/16/32/120) Version 50 and prior,RnSFCPU (n=08/16/32/120) Version 22 and prior,RnPCPU(n=08/16/32/120) Version 24 and prior,RnPSFCPU(n=08/16/32/120) Version 05 and prior,FX5U(C)-M*/,FX5UC-32M/-TS Version 1.210 and prior,FX5UJ-M/ Version 1.000,FX5-ENET Version 1.002 and prior,FX5-ENET/IP Version 1.002 and prior,FX3U-ENET-ADP Version 1.22 and prior,FX3GE-M/* the first 3 digits of serial number 20X and prior,FX3U-ENET Version 1.14 and prior,FX3U-ENET-L Version 1.14 and prior,FX3U-ENET-P502 Version 1.14 and prior,FX5-CCLGN-MS Version 1.000,IU1-1M20-D all versions,LE7-40GU-L all versions,GOT2000 Series GT21 Model all versions,GS Series all versions,GOT1000 Series GT14 Model all versions,GT25-J71GN13-T2 all versions,FR-A800-E Series production date December 2020 and prior,FR-F800-E Series production date December 2020 and prior,FR-A8NCG Production date August 2020 and prior,FR-E800-EPA Series Production date July 2020 and prior,FR-E800-EPB Series Production date July 2020 and prior,Conveyor Tracking Application APR-nTR3FH APR-nTR6FH APR-nTR12FH APR-nTR20FH(n=1,2) all versions (Discontinued product),MR-JE-C all versions,MR-J4-TM all versions

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202010-0395",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "fr-f842-e",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "rnpsfcpu\\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "qj71ws96",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx3g-14mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fr-f860-e",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "q24dhccpu-v",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx5uj-24mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.000"
      },
      {
        "model": "fx3u-enet",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "q24dhccpu-vg",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "rnpcpu\\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "got2000 series gt21",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx3g-60mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx5-enet-adp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fr-a860-e",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "rd55up06-v",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx3g-40mr\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx3g-40mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx5uc-32mr\\/ds-ts",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.210"
      },
      {
        "model": "got1000 series gt14",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "conveyor tracking application apr-ntr12fh",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "rd78ghv",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fr-f820-e",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fr-f840-e",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "qnudehcpu\\",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "22081"
      },
      {
        "model": "qnudpvcpu\\",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "22031"
      },
      {
        "model": "fx5uj-24mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.000"
      },
      {
        "model": "nz2gacp620-60",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "rnsfcpu \\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "rj71en71",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx5-enet",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fr-a862-e",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "qj71e71-100",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "mr-j4-tm",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "r12ccpu-v",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "mr-je-c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx3g-40mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx5uj-40mt\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.000"
      },
      {
        "model": "fx3g-32 mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "qnudvcpu\\",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "22031"
      },
      {
        "model": "lj71e71-100",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx5uj-40mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.000"
      },
      {
        "model": "fx5uc-32mt\\/d",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.210"
      },
      {
        "model": "fx5uj-60mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.000"
      },
      {
        "model": "fx3g-14mr\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx3g-14mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx5-cclgn-ms",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fr-a8ncge",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "2020-08"
      },
      {
        "model": "qj71mt91",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fr-a820-e",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx5uj-60mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.000"
      },
      {
        "model": "fr-e800-epa",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "2020-07"
      },
      {
        "model": "got simple series gs21",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fr-e800-epb",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "2020-07"
      },
      {
        "model": "fx3g-14mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "rj71gn11-t2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx3g-40mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "le7-40gu-l",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx5uj-40mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.000"
      },
      {
        "model": "iu1-1m20-d",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "nz2gacp620-300",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "l26cpu-\\ bt",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "22051"
      },
      {
        "model": "nz2ft-mt",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "q06ccpu-v",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fr-f862-e",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "conveyor tracking application apr-ntr6fh",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-24mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "rd78gn\\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx3g-24mr\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "lncpu\\ \\",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "22051"
      },
      {
        "model": "fx3g-60mr\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "conveyor tracking application apr-ntr3fh",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx3g-24mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "conveyor tracking application apr-ntr20fh\\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-enet-l",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fr-a842-e",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fr-a840-e",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx3g-60mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "rd78ghw",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx5uc-32mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.210"
      },
      {
        "model": "rncpu\\ t",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "18"
      },
      {
        "model": "fx3u-enet-p502",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "gt25-j71gn13-t2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx5uc-32mt\\/ds-ts",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.210"
      },
      {
        "model": "q03udecpu",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "22081"
      },
      {
        "model": "fx5uj-60mt\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.000"
      },
      {
        "model": "fx5uc-32mt\\/dss-ts",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.210"
      },
      {
        "model": "fx5-enet\\/ip",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx3g-60mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "rncpu\\",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "50"
      },
      {
        "model": "fx3g-24mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "rnencpu\\",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "50"
      },
      {
        "model": "qj71mes96",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx5uj-24mt\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.000"
      },
      {
        "model": "rd55up12-v",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "nz2ft-eip",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "(multiple products)"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * ac the servo  melservo"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * lossnay central ventilation system"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * display  got"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": null
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * air conditioning control system  / centralized controller"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * air conditioning control system  / expansion controller"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * energy measurement unit"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "affected products    s vary widely. for more information, please check the information provided by the developer."
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * range hood fan"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * data collection analyzer  melqic"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * hems compatible adapter, lan adapter"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * air conditioning control system  / bm adapter"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * room air conditioner"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * bath drying/heating/ventilation system"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * solar power system color monitor eco guide"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * ventilation fan for duct"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * tension controller"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * inverter  freqrol"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * mitsubishi energy saving dem  monitoring server  e-energy"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * robot  melfa"
      },
      {
        "model": "melsec iq-f",
        "scope": null,
        "trust": 0.7,
        "vendor": "mitsubishi electric",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-20-1207"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008251"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-16226"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Ta-Lun Yen of TXOne IoT/ICS Security Research Labs (Trend Micro)",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-20-1207"
      }
    ],
    "trust": 0.7
  },
  "cve": "CVE-2020-16226",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2020-16226",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.1,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2020-16226",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "Low",
            "baseScore": 7.3,
            "baseSeverity": "High",
            "confidentialityImpact": "Low",
            "exploitabilityScore": null,
            "id": "CVE-2020-16226",
            "impactScore": null,
            "integrityImpact": "Low",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "ZDI",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2020-16226",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 0.7,
            "userInteraction": "NONE",
            "vectorString": "AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2020-16226",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2020-16226",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "ZDI",
            "id": "CVE-2020-16226",
            "trust": 0.7,
            "value": "CRITICAL"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202009-074",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULMON",
            "id": "CVE-2020-16226",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-20-1207"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-16226"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008251"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202009-074"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-16226"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Multiple Mitsubishi Electric products are vulnerable to impersonations of a legitimate device by a malicious actor, which may allow an attacker to remotely execute arbitrary commands. of multiple Mitsubishi Electric products TCP A vulnerability in session management exists in the protocol stack. This vulnerability information is provided by the developer for the purpose of dissemination to product users. Authentication is not required to exploit this vulnerability.The specific flaw exists within the processing of ACK packets. When generating ACK packets, the application uses a predictable sequence number. An attacker can leverage this vulnerability to execute arbitrary code in the context of the current process. Mitsubishi Electric gt14 model\u662f\u65e5\u672c\u4e09\u83f1\u7535\u673a\uff08Mitsubishi Electric\uff09\u516c\u53f8\u7684\u4e00\u4e2a\u7528\u4e8e\u5de5\u4e1a\u751f\u4ea7\u8fc7\u7a0b\u4e2d\u63d0\u4f9b\u4eba\u673a\u4ea4\u4e92\u754c\u9762\u7684\u8bbe\u5907. \nMitsubishi Electric \u591a\u4e2a\u4ea7\u54c1\u5b58\u5728\u547d\u4ee4\u6267\u884c\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u5141\u8bb8\u653b\u51fb\u8005\u5192\u5145\u5408\u6cd5\u8bbe\u5907\uff0c\u4ece\u800c\u4f7f\u653b\u51fb\u8005\u80fd\u591f\u8fdc\u7a0b\u6267\u884c\u4efb\u610f\u547d\u4ee4\u3002\u4ee5\u4e0b\u4ea7\u54c1\u548c\u7248\u672c\u53d7\u5230\u5f71\u54cd\uff1aQJ71MES96 all versions\uff0cQJ71WS96 all versions\uff0cQ06CCPU-V all versions\uff0cQ24DHCCPU-V all versions\uff0cQ24DHCCPU-VG all versions\uff0cR12CCPU-V Version 13 and prior\uff0cRD55UP06-V Version 09 and prior\uff0cRD55UP12-V Version 01\uff0cRJ71GN11-T2 Version 11 and prior\uff0cRJ71EN71 all versions\uff0cQJ71E71-100 all versions\uff0cLJ71E71-100 all versions\uff0cQJ71MT91 all versions\uff0cRD78Gn(n=4,8,16,32,64) all versions\uff0cRD78GHV all versions\uff0cRD78GHW all versions\uff0cNZ2GACP620-60 all versions\uff0cNZ2GACP620-300 all versions\uff0cNZ2FT-MT all versions\uff0cNZ2FT-EIP all versions\uff0cQ03UDECPU the first 5 digits of serial number 22081 and prior\uff0cQnUDEHCPU(n=04/06/10/13/20/26/50/100) the first 5 digits of serial number 22081 and prior\uff0cQnUDVCPU(n=03/04/06/13/26) the first 5 digits of serial number 22031 and prior\uff0cQnUDPVCPU(n=04/06/13/26) the first 5 digits of serial number 22031 and prior\uff0cLnCPU(-P)(n=02/06/26) the first 5 digits of serial number 22051 and prior\uff0cL26CPU-(P)BT the first 5 digits of serial number 22051 and prior\uff0cRnCPU(n=00/01/02) Version 18 and prior\uff0cRnCPU(n=04/08/16/32/120) Version 50 and prior\uff0cRnENCPU(n=04/08/16/32/120) Version 50 and prior\uff0cRnSFCPU (n=08/16/32/120) Version 22 and prior\uff0cRnPCPU(n=08/16/32/120) Version 24 and prior\uff0cRnPSFCPU(n=08/16/32/120) Version 05 and prior\uff0cFX5U(C)-**M*/**\uff0cFX5UC-32M*/**-TS Version 1.210 and prior\uff0cFX5UJ-**M*/** Version 1.000\uff0cFX5-ENET Version 1.002 and prior\uff0cFX5-ENET/IP Version 1.002 and prior\uff0cFX3U-ENET-ADP Version 1.22 and prior\uff0cFX3GE-**M*/** the first 3 digits of serial number 20X and prior\uff0cFX3U-ENET Version 1.14 and prior\uff0cFX3U-ENET-L Version 1.14 and prior\uff0cFX3U-ENET-P502 Version 1.14 and prior\uff0cFX5-CCLGN-MS Version 1.000\uff0cIU1-1M20-D all versions\uff0cLE7-40GU-L all versions\uff0cGOT2000 Series GT21 Model all versions\uff0cGS Series all versions\uff0cGOT1000 Series GT14 Model all versions\uff0cGT25-J71GN13-T2 all versions\uff0cFR-A800-E Series production date December 2020 and prior\uff0cFR-F800-E Series production date December 2020 and prior\uff0cFR-A8NCG Production date August 2020 and prior\uff0cFR-E800-EPA Series Production date July 2020 and prior\uff0cFR-E800-EPB Series Production date July 2020 and prior\uff0cConveyor Tracking Application APR-nTR3FH APR-nTR6FH APR-nTR12FH APR-nTR20FH(n=1,2) all versions (Discontinued product)\uff0cMR-JE-C all versions\uff0cMR-J4-TM all versions",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-16226"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008251"
      },
      {
        "db": "ZDI",
        "id": "ZDI-20-1207"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202009-074"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-16226"
      }
    ],
    "trust": 2.88
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-16226",
        "trust": 3.2
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-20-245-01",
        "trust": 2.5
      },
      {
        "db": "JVN",
        "id": "JVNVU93926439",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008251",
        "trust": 0.8
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-10966",
        "trust": 0.7
      },
      {
        "db": "ZDI",
        "id": "ZDI-20-1207",
        "trust": 0.7
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2020.3041",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2022.4767",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202009-074",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-16226",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-20-1207"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-16226"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008251"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202009-074"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-16226"
      }
    ]
  },
  "id": "VAR-202010-0395",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.41666666
  },
  "last_update_date": "2024-11-23T21:51:16.463000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "of our products TCP Spoofing Vulnerability in Protocol Stack",
        "trust": 0.8,
        "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-009.pdf"
      },
      {
        "title": "Mitsubishi Electric has issued an update to correct this vulnerability.",
        "trust": 0.7,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-245-01"
      },
      {
        "title": "mitsubishielectric Fixes for remote command execution vulnerabilities",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=127702"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-20-1207"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008251"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202009-074"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-342",
        "trust": 1.0
      },
      {
        "problemtype": "Lack of information (CWE-noinfo) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008251"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-16226"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.8,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-245-01"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu93926439/"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2020.3041/"
      },
      {
        "trust": 0.6,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-16226"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2022.4767"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/342.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-245-01"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-20-1207"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-16226"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008251"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202009-074"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-16226"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "ZDI",
        "id": "ZDI-20-1207"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-16226"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008251"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202009-074"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-16226"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-09-08T00:00:00",
        "db": "ZDI",
        "id": "ZDI-20-1207"
      },
      {
        "date": "2020-10-05T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-16226"
      },
      {
        "date": "2020-09-07T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-008251"
      },
      {
        "date": "2020-09-01T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202009-074"
      },
      {
        "date": "2020-10-05T18:15:13.133000",
        "db": "NVD",
        "id": "CVE-2020-16226"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-09-17T00:00:00",
        "db": "ZDI",
        "id": "ZDI-20-1207"
      },
      {
        "date": "2020-10-22T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-16226"
      },
      {
        "date": "2022-09-26T08:55:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-008251"
      },
      {
        "date": "2022-09-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202009-074"
      },
      {
        "date": "2024-11-21T05:06:58.517000",
        "db": "NVD",
        "id": "CVE-2020-16226"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202009-074"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "of multiple Mitsubishi Electric products \u00a0TCP\u00a0 Session management flaw in protocol stack",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008251"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Command execution",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202009-074"
      }
    ],
    "trust": 0.6
  }
}