Vulnerabilites related to tenda - fh1206_firmware
Vulnerability from fkie_nvd
Published
2024-08-23 17:15
Modified
2024-12-13 15:15
Summary
Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the functino formWrlExtraGet.
Impacted products
Vendor Product Version
tenda fh1206_firmware 1.2.0.8\(8155\)
tenda fh1206 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:fh1206_firmware:1.2.0.8\\(8155\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "066BD21A-2694-474D-B885-6E9A2A1DBCFF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the functino formWrlExtraGet."
    },
    {
      "lang": "es",
      "value": "Tenda FH1206 V1.2.0.8(8155)_EN contiene una vulnerabilidad de desbordamiento de b\u00fafer a trav\u00e9s de la funci\u00f3n formWrlExtraGet."
    }
  ],
  "id": "CVE-2024-44387",
  "lastModified": "2024-12-13T15:15:24.313",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-08-23T17:15:10.243",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Broken Link"
      ],
      "url": "https://github.com/GroundCTL2MajorTom/pocs/blob/main/tenda_FH1206_buffer_overflow1.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-08-15 17:15
Modified
2024-08-16 18:35
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the delno parameter in the fromPptpUserSetting function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Impacted products
Vendor Product Version
tenda fh1206_firmware v02.03.01.35
tenda fh1206 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:fh1206_firmware:v02.03.01.35:*:*:*:*:*:*:*",
              "matchCriteriaId": "6B880B95-84CF-4C01-B403-3E2F0686DCAF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the delno parameter in the fromPptpUserSetting function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
    },
    {
      "lang": "es",
      "value": " Se descubri\u00f3 que Tenda FH1206 v02.03.01.35 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro delno en la funci\u00f3n fromPptpUserSetting. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada."
    }
  ],
  "id": "CVE-2024-42981",
  "lastModified": "2024-08-16T18:35:16.483",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-08-15T17:15:21.240",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromPptpUserSetting.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-400"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-11-30 13:15
Modified
2024-12-10 23:21
Summary
A vulnerability classified as problematic was found in Tenda FH451, FH1201, FH1202 and FH1206 up to 20241129. Affected by this vulnerability is the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
References
Impacted products
Vendor Product Version
tenda fh451_firmware 1.0.0.5
tenda fh451_firmware 1.0.0.7
tenda fh451_firmware 1.0.0.9
tenda fh451 -
tenda fh1201_firmware 1.2.0.8\(8155\)
tenda fh1201_firmware 1.2.0.14\(408\)_en
tenda fh1201 -
tenda fh1202_firmware 1.2.0.9
tenda fh1202_firmware 1.2.0.14\(408\)
tenda fh1202_firmware 1.2.0.14\(408\)_en
tenda fh1202 -
tenda fh1206_firmware 1.2.0.8\(8155\)
tenda fh1206 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:fh451_firmware:1.0.0.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "645BB5C8-F542-4D2A-81EB-168982028C42",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:tenda:fh451_firmware:1.0.0.7:*:*:*:*:*:*:*",
              "matchCriteriaId": "7587331C-8CDC-43FA-869B-CACC9E39CC4F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:tenda:fh451_firmware:1.0.0.9:*:*:*:*:*:*:*",
              "matchCriteriaId": "A7521568-7BCD-43F8-9F20-440DF3919D5D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:fh451:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "97A8BF83-E42A-4D6B-A52D-146FE1AEE2B0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:fh1201_firmware:1.2.0.8\\(8155\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "0368A8C0-C2C0-477E-A0C2-4D941B963520",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:tenda:fh1201_firmware:1.2.0.14\\(408\\)_en:*:*:*:*:*:*:*",
              "matchCriteriaId": "84F68F46-077A-48C8-AA85-342A2264BF1C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:fh1201:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "67A1C59D-AE12-4410-9173-B9B9A72B3AE4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:fh1202_firmware:1.2.0.9:*:*:*:*:*:*:*",
              "matchCriteriaId": "9DA584AC-7E1F-4FF7-91EA-F82AC2D2D3CC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:tenda:fh1202_firmware:1.2.0.14\\(408\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "B9FD9D0A-39F4-4AD8-AEE0-71C9E77D2799",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:tenda:fh1202_firmware:1.2.0.14\\(408\\)_en:*:*:*:*:*:*:*",
              "matchCriteriaId": "9A318B1F-C8E5-4C39-A1B3-83C5693CEB61",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:fh1202:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A632A11-60A0-457C-A039-BED32F83BD52",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:fh1206_firmware:1.2.0.8\\(8155\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "066BD21A-2694-474D-B885-6E9A2A1DBCFF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability classified as problematic was found in Tenda FH451, FH1201, FH1202 and FH1206 up to 20241129. Affected by this vulnerability is the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
    },
    {
      "lang": "es",
      "value": "Se ha detectado una vulnerabilidad clasificada como problem\u00e1tica en Tenda FH451, FH1201, FH1202 y FH1206 hasta 20241129. Esta vulnerabilidad afecta a la funci\u00f3n websReadEvent del archivo /goform/GetIPTV. La manipulaci\u00f3n del argumento Content-Length provoca la desreferenciaci\u00f3n de un puntero nulo. El ataque puede ejecutarse de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse."
    }
  ],
  "id": "CVE-2024-12002",
  "lastModified": "2024-12-10T23:21:19.827",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 4.0,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "cna@vuldb.com",
        "type": "Secondary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "LOW",
          "baseScore": 4.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 1.4,
        "source": "cna@vuldb.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "automatable": "NOT_DEFINED",
          "availabilityRequirements": "NOT_DEFINED",
          "baseScore": 5.3,
          "baseSeverity": "MEDIUM",
          "confidentialityRequirements": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirements": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubsequentSystemAvailability": "NOT_DEFINED",
          "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED",
          "modifiedSubsequentSystemIntegrity": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnerableSystemAvailability": "NOT_DEFINED",
          "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED",
          "modifiedVulnerableSystemIntegrity": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "recovery": "NOT_DEFINED",
          "safety": "NOT_DEFINED",
          "subsequentSystemAvailability": "NONE",
          "subsequentSystemConfidentiality": "NONE",
          "subsequentSystemIntegrity": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "vulnerableSystemAvailability": "LOW",
          "vulnerableSystemConfidentiality": "NONE",
          "vulnerableSystemIntegrity": "NONE"
        },
        "source": "cna@vuldb.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-11-30T13:15:04.610",
  "references": [
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/Kalvin2077/tenda-fh-cve"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Permissions Required",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?ctiid.286417"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?id.286417"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?submit.453974"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Product"
      ],
      "url": "https://www.tenda.com.cn/"
    }
  ],
  "sourceIdentifier": "cna@vuldb.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-404"
        },
        {
          "lang": "en",
          "value": "CWE-476"
        }
      ],
      "source": "cna@vuldb.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-476"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-08-15 17:15
Modified
2024-08-16 18:11
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromwebExcptypemanFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Impacted products
Vendor Product Version
tenda fh1206_firmware 02.03.01.35
tenda fh1206 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:fh1206_firmware:02.03.01.35:*:*:*:*:*:*:*",
              "matchCriteriaId": "5546734B-3297-4E57-95C6-52D7F6B44513",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromwebExcptypemanFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
    },
    {
      "lang": "es",
      "value": " Se descubri\u00f3 que Tenda FH1206 v02.03.01.35 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro page en la funci\u00f3n fromwebExcptypemanFilter. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada."
    }
  ],
  "id": "CVE-2024-42974",
  "lastModified": "2024-08-16T18:11:47.980",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-08-15T17:15:20.667",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit"
      ],
      "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromwebExcptypemanFilter.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-08-15 17:15
Modified
2024-08-16 18:11
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the pptpPPW parameter in the fromAdvSetWan function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Impacted products
Vendor Product Version
tenda fh1206_firmware 02.03.01.35
tenda fh1206 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:fh1206_firmware:02.03.01.35:*:*:*:*:*:*:*",
              "matchCriteriaId": "5546734B-3297-4E57-95C6-52D7F6B44513",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the pptpPPW parameter in the fromAdvSetWan function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
    },
    {
      "lang": "es",
      "value": " Se descubri\u00f3 que Tenda FH1206 v02.03.01.35 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro pptpPPW en la funci\u00f3n fromAdvSetWan. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada."
    }
  ],
  "id": "CVE-2024-42983",
  "lastModified": "2024-08-16T18:11:08.020",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-08-15T17:15:21.433",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit"
      ],
      "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromAdvSetWan_pptpPPW.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-08-13 01:24
Modified
2024-08-22 13:23
Summary
A vulnerability was found in Tenda FH1206 02.03.01.35 and classified as critical. Affected by this issue is the function formSafeEmailFilter of the file /goform/SafeEmailFilter of the component HTTP POST Request Handler. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
Impacted products
Vendor Product Version
tenda fh1206_firmware v02.03.01.35
tenda fh1206 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:fh1206_firmware:v02.03.01.35:*:*:*:*:*:*:*",
              "matchCriteriaId": "6B880B95-84CF-4C01-B403-3E2F0686DCAF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability was found in Tenda FH1206 02.03.01.35 and classified as critical. Affected by this issue is the function formSafeEmailFilter of the file /goform/SafeEmailFilter of the component HTTP POST Request Handler. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad fue encontrada en Tenda FH1206 02.03.01.35 y clasificada como cr\u00edtica. La funci\u00f3n formSafeEmailFilter del archivo /goform/SafeEmailFilter del componente HTTP POST Request Handler es afectada por esta vulnerabilidad. La manipulaci\u00f3n de la p\u00e1gina de argumentos provoca un desbordamiento del b\u00fafer basado en la pila. El ataque puede lanzarse de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera."
    }
  ],
  "id": "CVE-2024-7707",
  "lastModified": "2024-08-22T13:23:20.327",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "cna@vuldb.com",
        "type": "Secondary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "cna@vuldb.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "automatable": "NOT_DEFINED",
          "availabilityRequirements": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirements": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirements": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubsequentSystemAvailability": "NOT_DEFINED",
          "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED",
          "modifiedSubsequentSystemIntegrity": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnerableSystemAvailability": "NOT_DEFINED",
          "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED",
          "modifiedVulnerableSystemIntegrity": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "recovery": "NOT_DEFINED",
          "safety": "NOT_DEFINED",
          "subsequentSystemAvailability": "NONE",
          "subsequentSystemConfidentiality": "NONE",
          "subsequentSystemIntegrity": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "vulnerableSystemAvailability": "HIGH",
          "vulnerableSystemConfidentiality": "HIGH",
          "vulnerableSystemIntegrity": "HIGH"
        },
        "source": "cna@vuldb.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-08-13T01:24:09.723",
  "references": [
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/VodkaVortex/IoT/blob/main/formSafeEmailFilter.md"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Permissions Required",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?ctiid.274190"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Permissions Required",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?id.274190"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?submit.385670"
    }
  ],
  "sourceIdentifier": "cna@vuldb.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "cna@vuldb.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-08-15 17:15
Modified
2024-08-16 17:35
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromSafeClientFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Impacted products
Vendor Product Version
tenda fh1206_firmware v02.03.01.35
tenda fh1206 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:fh1206_firmware:v02.03.01.35:*:*:*:*:*:*:*",
              "matchCriteriaId": "6B880B95-84CF-4C01-B403-3E2F0686DCAF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromSafeClientFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
    },
    {
      "lang": "es",
      "value": " Se descubri\u00f3 que Tenda FH1206 v02.03.01.35 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro page en la funci\u00f3n fromSafeClientFilter. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada."
    }
  ],
  "id": "CVE-2024-42976",
  "lastModified": "2024-08-16T17:35:09.687",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-08-15T17:15:20.767",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromSafeClientFilter_page.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-08-15 17:15
Modified
2024-08-16 18:10
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromP2pListFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Impacted products
Vendor Product Version
tenda fh1206_firmware 02.03.01.35
tenda fh1206 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:fh1206_firmware:02.03.01.35:*:*:*:*:*:*:*",
              "matchCriteriaId": "5546734B-3297-4E57-95C6-52D7F6B44513",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromP2pListFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
    },
    {
      "lang": "es",
      "value": "Se descubri\u00f3 que Tenda FH1206 v02.03.01.35 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro page en la funci\u00f3n fromP2pListFilter. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada."
    }
  ],
  "id": "CVE-2024-42984",
  "lastModified": "2024-08-16T18:10:53.680",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-08-15T17:15:21.523",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit"
      ],
      "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromP2pListFilter.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-08-15 17:15
Modified
2024-08-16 18:35
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromSafeUrlFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Impacted products
Vendor Product Version
tenda fh1206_firmware v02.03.01.35
tenda fh1206 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:fh1206_firmware:v02.03.01.35:*:*:*:*:*:*:*",
              "matchCriteriaId": "6B880B95-84CF-4C01-B403-3E2F0686DCAF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromSafeUrlFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
    },
    {
      "lang": "es",
      "value": " Se descubri\u00f3 que Tenda FH1206 v02.03.01.35 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro page en la funci\u00f3n fromSafeUrlFilter. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada."
    }
  ],
  "id": "CVE-2024-42969",
  "lastModified": "2024-08-16T18:35:15.027",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-08-15T17:15:20.480",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromSafeMacFilter%20_page.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-400"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-08-15 17:15
Modified
2024-08-16 17:35
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromNatlimit function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Impacted products
Vendor Product Version
tenda fh1206_firmware v02.03.01.35
tenda fh1206 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:fh1206_firmware:v02.03.01.35:*:*:*:*:*:*:*",
              "matchCriteriaId": "6B880B95-84CF-4C01-B403-3E2F0686DCAF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromNatlimit function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
    },
    {
      "lang": "es",
      "value": " Se descubri\u00f3 que Tenda FH1206 v02.03.01.35 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro page en la funci\u00f3n fromNatlimit. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada."
    }
  ],
  "id": "CVE-2024-42985",
  "lastModified": "2024-08-16T17:35:10.400",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-08-15T17:15:21.623",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromNatlimit.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-08-12 13:38
Modified
2024-08-21 18:48
Summary
A vulnerability was found in Tenda FH1206 1.2.0.8. It has been declared as critical. Affected by this vulnerability is the function fromSafeClientFilter/fromSafeMacFilter/fromSafeUrlFilter. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Impacted products
Vendor Product Version
tenda fh1206_firmware 1.2.0.8\(8155\)
tenda fh1206 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:fh1206_firmware:1.2.0.8\\(8155\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "066BD21A-2694-474D-B885-6E9A2A1DBCFF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability was found in Tenda FH1206 1.2.0.8. It has been declared as critical. Affected by this vulnerability is the function fromSafeClientFilter/fromSafeMacFilter/fromSafeUrlFilter. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
    },
    {
      "lang": "es",
      "value": "Se encontr\u00f3 una vulnerabilidad en Tenda FH1206 1.2.0.8. Ha sido declarada cr\u00edtica. La funci\u00f3n fromSafeClientFilter/fromSafeMacFilter/fromSafeUrlFilter es afectada por esta vulnerabilidad. La manipulaci\u00f3n conduce a un desbordamiento del b\u00fafer basado en pila. El ataque se puede lanzar de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera."
    }
  ],
  "id": "CVE-2024-7615",
  "lastModified": "2024-08-21T18:48:19.590",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "cna@vuldb.com",
        "type": "Secondary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "cna@vuldb.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "automatable": "NOT_DEFINED",
          "availabilityRequirements": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirements": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirements": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubsequentSystemAvailability": "NOT_DEFINED",
          "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED",
          "modifiedSubsequentSystemIntegrity": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnerableSystemAvailability": "NOT_DEFINED",
          "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED",
          "modifiedVulnerableSystemIntegrity": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "recovery": "NOT_DEFINED",
          "safety": "NOT_DEFINED",
          "subsequentSystemAvailability": "NONE",
          "subsequentSystemConfidentiality": "NONE",
          "subsequentSystemIntegrity": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "vulnerableSystemAvailability": "HIGH",
          "vulnerableSystemConfidentiality": "HIGH",
          "vulnerableSystemIntegrity": "HIGH"
        },
        "source": "cna@vuldb.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-08-12T13:38:44.840",
  "references": [
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/BeaCox/IoT_vuln/tree/main/tenda/FH1206/Safe_Client_or_Url_or_Mac_Filter_bof"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://vuldb.com/?ctiid.273985"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://vuldb.com/?id.273985"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://vuldb.com/?submit.383693"
    }
  ],
  "sourceIdentifier": "cna@vuldb.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "cna@vuldb.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-08-15 17:15
Modified
2024-08-16 18:14
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the Go parameter in the fromSafeUrlFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Impacted products
Vendor Product Version
tenda fh1206_firmware 02.03.01.35
tenda fh1206 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:fh1206_firmware:02.03.01.35:*:*:*:*:*:*:*",
              "matchCriteriaId": "5546734B-3297-4E57-95C6-52D7F6B44513",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the Go parameter in the fromSafeUrlFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
    },
    {
      "lang": "es",
      "value": " Se descubri\u00f3 que Tenda FH1206 v02.03.01.35 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro Go en la funci\u00f3n fromSafeUrlFilter. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada."
    }
  ],
  "id": "CVE-2024-42968",
  "lastModified": "2024-08-16T18:14:39.303",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-08-15T17:15:20.373",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit"
      ],
      "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromSafeMacFilter_Go.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-08-15 17:15
Modified
2024-10-24 20:35
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the qos parameter in the fromqossetting function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Impacted products
Vendor Product Version
tenda fh1206_firmware v02.03.01.35
tenda fh1206 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:fh1206_firmware:v02.03.01.35:*:*:*:*:*:*:*",
              "matchCriteriaId": "6B880B95-84CF-4C01-B403-3E2F0686DCAF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the qos parameter in the fromqossetting function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
    },
    {
      "lang": "es",
      "value": "Se descubri\u00f3 que Tenda FH1206 v02.03.01.35 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro qos en la funci\u00f3n fromqossetting. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada."
    }
  ],
  "id": "CVE-2024-42977",
  "lastModified": "2024-10-24T20:35:08.860",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-08-15T17:15:20.860",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromqossetting_qos.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-08-15 17:15
Modified
2024-08-16 14:35
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromVirtualSer function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Impacted products
Vendor Product Version
tenda fh1206_firmware v02.03.01.35
tenda fh1206 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:fh1206_firmware:v02.03.01.35:*:*:*:*:*:*:*",
              "matchCriteriaId": "6B880B95-84CF-4C01-B403-3E2F0686DCAF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromVirtualSer function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
    },
    {
      "lang": "es",
      "value": "Se descubri\u00f3 que Tenda FH1206 v02.03.01.35 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro page en la funci\u00f3n fromVirtualSer. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada."
    }
  ],
  "id": "CVE-2024-42982",
  "lastModified": "2024-08-16T14:35:03.793",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "LOW",
          "baseScore": 5.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 1.4,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-08-15T17:15:21.337",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromVirtualSer.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-08-12 13:38
Modified
2024-08-21 18:48
Summary
A vulnerability was found in Tenda FH1206 1.2.0.8(8155). It has been classified as critical. Affected is the function fromqossetting of the file /goform/qossetting. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Impacted products
Vendor Product Version
tenda fh1206_firmware 1.2.0.8\(8155\)
tenda fh1206 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:fh1206_firmware:1.2.0.8\\(8155\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "066BD21A-2694-474D-B885-6E9A2A1DBCFF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability was found in Tenda FH1206 1.2.0.8(8155). It has been classified as critical. Affected is the function fromqossetting of the file /goform/qossetting. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
    },
    {
      "lang": "es",
      "value": "Se encontr\u00f3 una vulnerabilidad en Tenda FH1206 1.2.0.8(8155). Ha sido clasificada como cr\u00edtica. La funci\u00f3n fromqossetting del fichero /goform/qossetting es afectada por la vulnerabilidad. La manipulaci\u00f3n de la p\u00e1gina de argumentos provoca un desbordamiento del b\u00fafer basado en la pila. Es posible lanzar el ataque de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera."
    }
  ],
  "id": "CVE-2024-7614",
  "lastModified": "2024-08-21T18:48:47.273",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "cna@vuldb.com",
        "type": "Secondary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "cna@vuldb.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "automatable": "NOT_DEFINED",
          "availabilityRequirements": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirements": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirements": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubsequentSystemAvailability": "NOT_DEFINED",
          "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED",
          "modifiedSubsequentSystemIntegrity": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnerableSystemAvailability": "NOT_DEFINED",
          "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED",
          "modifiedVulnerableSystemIntegrity": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "recovery": "NOT_DEFINED",
          "safety": "NOT_DEFINED",
          "subsequentSystemAvailability": "NONE",
          "subsequentSystemConfidentiality": "NONE",
          "subsequentSystemIntegrity": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "vulnerableSystemAvailability": "HIGH",
          "vulnerableSystemConfidentiality": "HIGH",
          "vulnerableSystemIntegrity": "HIGH"
        },
        "source": "cna@vuldb.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-08-12T13:38:44.563",
  "references": [
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/BeaCox/IoT_vuln/tree/main/tenda/FH1206/qossetting_bof"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://vuldb.com/?ctiid.273984"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://vuldb.com/?id.273984"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://vuldb.com/?submit.383692"
    }
  ],
  "sourceIdentifier": "cna@vuldb.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "cna@vuldb.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-08-15 17:15
Modified
2024-08-16 18:11
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the frmL7ProtForm function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Impacted products
Vendor Product Version
tenda fh1206_firmware 02.03.01.35
tenda fh1206 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:fh1206_firmware:02.03.01.35:*:*:*:*:*:*:*",
              "matchCriteriaId": "5546734B-3297-4E57-95C6-52D7F6B44513",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the frmL7ProtForm function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
    },
    {
      "lang": "es",
      "value": " Se descubri\u00f3 que Tenda FH1206 v02.03.01.35 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro page en la funci\u00f3n frmL7ProtForm. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada."
    }
  ],
  "id": "CVE-2024-42979",
  "lastModified": "2024-08-16T18:11:41.197",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-08-15T17:15:21.057",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit"
      ],
      "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/frmL7ProtForm.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-08-12 13:38
Modified
2024-08-21 18:47
Summary
A vulnerability was found in Tenda FH1206 1.2.0.8(8155) and classified as critical. This issue affects the function fromGstDhcpSetSer of the file /goform/GstDhcpSetSer. The manipulation of the argument dips leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Impacted products
Vendor Product Version
tenda fh1206_firmware 1.2.0.8\(8155\)
tenda fh1206 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:fh1206_firmware:1.2.0.8\\(8155\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "066BD21A-2694-474D-B885-6E9A2A1DBCFF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability was found in Tenda FH1206 1.2.0.8(8155) and classified as critical. This issue affects the function fromGstDhcpSetSer of the file /goform/GstDhcpSetSer. The manipulation of the argument dips leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad fue encontrada en Tenda FH1206 1.2.0.8(8155) y clasificada como cr\u00edtica. Este problema afecta la funci\u00f3n fromGstDhcpSetSer del archivo /goform/GstDhcpSetSer. La manipulaci\u00f3n del argumento dips conduce a un desbordamiento del b\u00fafer. El ataque puede iniciarse de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera."
    }
  ],
  "id": "CVE-2024-7613",
  "lastModified": "2024-08-21T18:47:11.523",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "cna@vuldb.com",
        "type": "Secondary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "cna@vuldb.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "automatable": "NOT_DEFINED",
          "availabilityRequirements": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirements": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirements": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubsequentSystemAvailability": "NOT_DEFINED",
          "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED",
          "modifiedSubsequentSystemIntegrity": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnerableSystemAvailability": "NOT_DEFINED",
          "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED",
          "modifiedVulnerableSystemIntegrity": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "recovery": "NOT_DEFINED",
          "safety": "NOT_DEFINED",
          "subsequentSystemAvailability": "NONE",
          "subsequentSystemConfidentiality": "NONE",
          "subsequentSystemIntegrity": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "vulnerableSystemAvailability": "HIGH",
          "vulnerableSystemConfidentiality": "HIGH",
          "vulnerableSystemIntegrity": "HIGH"
        },
        "source": "cna@vuldb.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-08-12T13:38:44.270",
  "references": [
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/BeaCox/IoT_vuln/tree/main/tenda/FH1206/GstDhcpSetSer_bof%26injection"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://vuldb.com/?ctiid.273983"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://vuldb.com/?id.273983"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://vuldb.com/?submit.383691"
    }
  ],
  "sourceIdentifier": "cna@vuldb.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-120"
        }
      ],
      "source": "cna@vuldb.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-08-23 17:15
Modified
2024-12-13 15:15
Summary
Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the function formWrlsafeset.
Impacted products
Vendor Product Version
tenda fh1206_firmware 1.2.0.8\(8155\)
tenda fh1206 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:fh1206_firmware:1.2.0.8\\(8155\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "066BD21A-2694-474D-B885-6E9A2A1DBCFF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the function formWrlsafeset."
    },
    {
      "lang": "es",
      "value": "Tenda FH1206 V1.2.0.8(8155)_EN contiene una vulnerabilidad de desbordamiento de b\u00fafer a trav\u00e9s de la funci\u00f3n formWrlsafeset."
    }
  ],
  "id": "CVE-2024-44390",
  "lastModified": "2024-12-13T15:15:13.767",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.0,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.1,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-08-23T17:15:10.300",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Broken Link"
      ],
      "url": "https://github.com/GroundCTL2MajorTom/pocs/blob/main/tenda_FH1206_buffer_overflow8.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-08-15 17:15
Modified
2024-09-03 18:35
Summary
An issue in the handler function in /goform/telnet of Tenda FH1206 v02.03.01.35 allows attackers to execute arbitrary commands via a crafted HTTP request.
Impacted products
Vendor Product Version
tenda fh1206_firmware v02.03.01.35
tenda fh1206 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:fh1206_firmware:v02.03.01.35:*:*:*:*:*:*:*",
              "matchCriteriaId": "6B880B95-84CF-4C01-B403-3E2F0686DCAF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue in the handler function in /goform/telnet of Tenda FH1206 v02.03.01.35 allows attackers to execute arbitrary commands via a crafted HTTP request."
    },
    {
      "lang": "es",
      "value": " Un problema en la funci\u00f3n de controlador en /goform/telnet de Tenda FH1206 v02.03.01.35 permite a los atacantes ejecutar comandos arbitrarios a trav\u00e9s de una solicitud HTTP manipulada."
    }
  ],
  "id": "CVE-2024-42978",
  "lastModified": "2024-09-03T18:35:13.590",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-08-15T17:15:20.960",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/telnet.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-08-15 17:15
Modified
2024-10-24 20:35
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the PPPOEPassword parameter in the fromAdvSetWan function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Impacted products
Vendor Product Version
tenda fh1206_firmware v02.03.1.35
tenda fh1206 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:fh1206_firmware:v02.03.1.35:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C2999F9-532B-40F6-8E72-E401ABA309F0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the PPPOEPassword parameter in the fromAdvSetWan function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
    },
    {
      "lang": "es",
      "value": " Se descubri\u00f3 que Tenda FH1206 v02.03.01.35 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro PPPOEPassword en la funci\u00f3n fromAdvSetWan. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada."
    }
  ],
  "id": "CVE-2024-42986",
  "lastModified": "2024-10-24T20:35:09.653",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-08-15T17:15:21.717",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromAdvSetWan_PPPOEPassword.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-08-15 17:15
Modified
2024-08-16 18:35
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the frmL7ImForm function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Impacted products
Vendor Product Version
tenda fh1206_firmware v02.03.01.35
tenda fh1206 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:fh1206_firmware:v02.03.01.35:*:*:*:*:*:*:*",
              "matchCriteriaId": "6B880B95-84CF-4C01-B403-3E2F0686DCAF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the frmL7ImForm function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
    },
    {
      "lang": "es",
      "value": " Se descubri\u00f3 que Tenda FH1206 v02.03.01.35 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro page en la funci\u00f3n frmL7ImForm. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada."
    }
  ],
  "id": "CVE-2024-42980",
  "lastModified": "2024-08-16T18:35:15.747",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-08-15T17:15:21.147",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/frmL7ImForm.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-400"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-08-15 17:15
Modified
2024-09-03 18:35
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the modino parameter in the fromPptpUserAdd function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Impacted products
Vendor Product Version
tenda fh1206_firmware v02.03.1.35
tenda fh1206 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:fh1206_firmware:v02.03.1.35:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C2999F9-532B-40F6-8E72-E401ABA309F0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the modino parameter in the fromPptpUserAdd function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
    },
    {
      "lang": "es",
      "value": " Se descubri\u00f3 que Tenda FH1206 v02.03.01.35 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro modino en la funci\u00f3n fromPptpUserAdd. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada."
    }
  ],
  "id": "CVE-2024-42987",
  "lastModified": "2024-09-03T18:35:13.793",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-08-15T17:15:21.820",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromPptpUserAdd.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-08-15 17:15
Modified
2024-08-16 18:11
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromSetlpBind function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Impacted products
Vendor Product Version
tenda fh1206_firmware 02.03.01.35
tenda fh1206 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:fh1206_firmware:02.03.01.35:*:*:*:*:*:*:*",
              "matchCriteriaId": "5546734B-3297-4E57-95C6-52D7F6B44513",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromSetlpBind function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
    },
    {
      "lang": "es",
      "value": "Se descubri\u00f3 que Tenda FH1206 v02.03.01.35 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro page en la funci\u00f3n fromSetlpBind. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada."
    }
  ],
  "id": "CVE-2024-42973",
  "lastModified": "2024-08-16T18:11:51.570",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-08-15T17:15:20.573",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit"
      ],
      "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromSetIpBind.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

cve-2024-42976
Vulnerability from cvelistv5
Published
2024-08-15 00:00
Modified
2024-08-16 16:52
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromSafeClientFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:fh1206_firmware:02.03.01.35:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "fh1206_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "02.03.01.35"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-42976",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-16T16:51:50.019464Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-16T16:52:50.420Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromSafeClientFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-15T16:20:33.088725",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromSafeClientFilter_page.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-42976",
    "datePublished": "2024-08-15T00:00:00",
    "dateReserved": "2024-08-05T00:00:00",
    "dateUpdated": "2024-08-16T16:52:50.420Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-42982
Vulnerability from cvelistv5
Published
2024-08-15 00:00
Modified
2024-08-16 13:49
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromVirtualSer function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:fh1206_firmware:02.03.01.35:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "fh1206_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "02.03.01.35"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-42982",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-16T13:46:25.323697Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-16T13:49:46.316Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromVirtualSer function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-15T16:20:28.268092",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromVirtualSer.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-42982",
    "datePublished": "2024-08-15T00:00:00",
    "dateReserved": "2024-08-05T00:00:00",
    "dateUpdated": "2024-08-16T13:49:46.316Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-42980
Vulnerability from cvelistv5
Published
2024-08-15 00:00
Modified
2024-08-16 17:53
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the frmL7ImForm function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:fh1206_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "fh1206_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "v02.03.01.35"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-42980",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-16T17:51:28.965096Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-400",
                "description": "CWE-400 Uncontrolled Resource Consumption",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-16T17:53:04.008Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the frmL7ImForm function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-15T16:20:29.870087",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/frmL7ImForm.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-42980",
    "datePublished": "2024-08-15T00:00:00",
    "dateReserved": "2024-08-05T00:00:00",
    "dateUpdated": "2024-08-16T17:53:04.008Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-42984
Vulnerability from cvelistv5
Published
2024-08-15 00:00
Modified
2024-08-15 17:51
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromP2pListFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:fh1206_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "fh1206_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "02.03.01.35"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-42984",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-15T17:49:31.369435Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-15T17:51:14.140Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromP2pListFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-15T16:20:25.028122",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromP2pListFilter.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-42984",
    "datePublished": "2024-08-15T00:00:00",
    "dateReserved": "2024-08-05T00:00:00",
    "dateUpdated": "2024-08-15T17:51:14.140Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-42969
Vulnerability from cvelistv5
Published
2024-08-15 00:00
Modified
2024-08-16 18:00
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromSafeUrlFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:fh1206_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "fh1206_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "0"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-42969",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-16T17:57:55.391150Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-400",
                "description": "CWE-400 Uncontrolled Resource Consumption",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-16T18:00:19.904Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromSafeUrlFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-15T16:20:36.978990",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromSafeMacFilter%20_page.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-42969",
    "datePublished": "2024-08-15T00:00:00",
    "dateReserved": "2024-08-05T00:00:00",
    "dateUpdated": "2024-08-16T18:00:19.904Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-42977
Vulnerability from cvelistv5
Published
2024-08-15 00:00
Modified
2024-10-24 19:46
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the qos parameter in the fromqossetting function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:fh1206_firmware:02.03.01.35:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "fh1206_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "02.03.01.35"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-42977",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-19T19:23:58.703089Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-787",
                "description": "CWE-787 Out-of-bounds Write",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-24T19:46:18.590Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the qos parameter in the fromqossetting function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-15T16:20:31.879002",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromqossetting_qos.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-42977",
    "datePublished": "2024-08-15T00:00:00",
    "dateReserved": "2024-08-05T00:00:00",
    "dateUpdated": "2024-10-24T19:46:18.590Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-7613
Vulnerability from cvelistv5
Published
2024-08-08 22:00
Modified
2024-08-09 12:53
Summary
A vulnerability was found in Tenda FH1206 1.2.0.8(8155) and classified as critical. This issue affects the function fromGstDhcpSetSer of the file /goform/GstDhcpSetSer. The manipulation of the argument dips leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Impacted products
Vendor Product Version
Tenda FH1206 Version: 1.2.0.8(8155)
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:fh1206_firmware:1.2.0.8\\(8155\\):*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "fh1206_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "1.2.0.8\\(8155\\)"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-7613",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-09T12:52:27.690645Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-09T12:53:19.799Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "FH1206",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.2.0.8(8155)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "BeaCox (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda FH1206 1.2.0.8(8155) and classified as critical. This issue affects the function fromGstDhcpSetSer of the file /goform/GstDhcpSetSer. The manipulation of the argument dips leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine kritische Schwachstelle wurde in Tenda FH1206 1.2.0.8(8155) gefunden. Betroffen davon ist die Funktion fromGstDhcpSetSer der Datei /goform/GstDhcpSetSer. Mittels Manipulieren des Arguments dips mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120 Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-08T22:00:10.117Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-273983 | Tenda FH1206 GstDhcpSetSer fromGstDhcpSetSer buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.273983"
        },
        {
          "name": "VDB-273983 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.273983"
        },
        {
          "name": "Submit #383691 | Tenda FH1206 1.2.0.8 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.383691"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/BeaCox/IoT_vuln/tree/main/tenda/FH1206/GstDhcpSetSer_bof%26injection"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-08-08T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-08-08T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-08-08T16:33:43.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda FH1206 GstDhcpSetSer fromGstDhcpSetSer buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-7613",
    "datePublished": "2024-08-08T22:00:10.117Z",
    "dateReserved": "2024-08-08T14:28:32.946Z",
    "dateUpdated": "2024-08-09T12:53:19.799Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-7614
Vulnerability from cvelistv5
Published
2024-08-08 22:31
Modified
2024-08-15 17:19
Summary
A vulnerability was found in Tenda FH1206 1.2.0.8(8155). It has been classified as critical. Affected is the function fromqossetting of the file /goform/qossetting. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
Impacted products
Vendor Product Version
Tenda FH1206 Version: 1.2.0.8(8155)
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:fh1206_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "fh1206_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "1.2.0.8(8155)"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-7614",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-09T17:25:15.765728Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-15T17:19:10.011Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "FH1206",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.2.0.8(8155)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "BeaCox (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda FH1206 1.2.0.8(8155). It has been classified as critical. Affected is the function fromqossetting of the file /goform/qossetting. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine kritische Schwachstelle in Tenda FH1206 1.2.0.8(8155) ausgemacht. Betroffen hiervon ist die Funktion fromqossetting der Datei /goform/qossetting. Durch das Manipulieren des Arguments page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-08T22:31:03.812Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-273984 | Tenda FH1206 qossetting fromqossetting stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.273984"
        },
        {
          "name": "VDB-273984 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.273984"
        },
        {
          "name": "Submit #383692 | Tenda FH1206 1.2.0.8 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.383692"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/BeaCox/IoT_vuln/tree/main/tenda/FH1206/qossetting_bof"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-08-08T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-08-08T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-08-08T16:33:44.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda FH1206 qossetting fromqossetting stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-7614",
    "datePublished": "2024-08-08T22:31:03.812Z",
    "dateReserved": "2024-08-08T14:28:35.326Z",
    "dateUpdated": "2024-08-15T17:19:10.011Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-44387
Vulnerability from cvelistv5
Published
2024-08-23 00:00
Modified
2024-08-23 17:00
Summary
Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the functino formWrlExtraGet.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:fh1206_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "fh1206_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "1.2.0.8\\(8155\\)_en"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-44387",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-23T16:54:00.527581Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-23T17:00:19.365Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the functino formWrlExtraGet."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-23T16:24:52.272074",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/GroundCTL2MajorTom/pocs/blob/main/tenda_FH1206_buffer_overflow1.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-44387",
    "datePublished": "2024-08-23T00:00:00",
    "dateReserved": "2024-08-21T00:00:00",
    "dateUpdated": "2024-08-23T17:00:19.365Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-42973
Vulnerability from cvelistv5
Published
2024-08-15 00:00
Modified
2024-08-15 18:01
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromSetlpBind function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:fh1206_firmware:02.03.01.35:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "fh1206_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "02.03.01.35"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-42973",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-15T17:59:44.216126Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-15T18:01:07.009Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromSetlpBind function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-15T16:20:36.175250",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromSetIpBind.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-42973",
    "datePublished": "2024-08-15T00:00:00",
    "dateReserved": "2024-08-05T00:00:00",
    "dateUpdated": "2024-08-15T18:01:07.009Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-42985
Vulnerability from cvelistv5
Published
2024-08-15 00:00
Modified
2024-08-16 16:51
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromNatlimit function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:fh1206_firmware:02.03.01.35:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "fh1206_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "02.03.01.35"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-42985",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-16T16:50:17.401074Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-16T16:51:29.762Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromNatlimit function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-15T16:20:24.866335",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromNatlimit.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-42985",
    "datePublished": "2024-08-15T00:00:00",
    "dateReserved": "2024-08-05T00:00:00",
    "dateUpdated": "2024-08-16T16:51:29.762Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-7615
Vulnerability from cvelistv5
Published
2024-08-08 22:31
Modified
2024-08-09 14:49
Summary
A vulnerability was found in Tenda FH1206 1.2.0.8. It has been declared as critical. Affected by this vulnerability is the function fromSafeClientFilter/fromSafeMacFilter/fromSafeUrlFilter. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Impacted products
Vendor Product Version
Tenda FH1206 Version: 1.2.0.8
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:fh1206_firmware:1.2.0.8\\(8155\\):*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "fh1206_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "1.2.0.8\\(8155\\)"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-7615",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-09T14:48:38.337744Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-09T14:49:47.340Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "FH1206",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.2.0.8"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "BeaCox (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda FH1206 1.2.0.8. It has been declared as critical. Affected by this vulnerability is the function fromSafeClientFilter/fromSafeMacFilter/fromSafeUrlFilter. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Tenda FH1206 1.2.0.8 wurde eine kritische Schwachstelle ausgemacht. Es geht um die Funktion fromSafeClientFilter/fromSafeMacFilter/fromSafeUrlFilter. Durch Manipulieren mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-08T22:31:05.314Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-273985 | Tenda FH1206 fromSafeUrlFilter stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.273985"
        },
        {
          "name": "VDB-273985 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.273985"
        },
        {
          "name": "Submit #383693 | Tenda FH1206 1.2.0.8 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.383693"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/BeaCox/IoT_vuln/tree/main/tenda/FH1206/Safe_Client_or_Url_or_Mac_Filter_bof"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-08-08T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-08-08T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-08-08T16:33:45.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda FH1206 fromSafeUrlFilter stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-7615",
    "datePublished": "2024-08-08T22:31:05.314Z",
    "dateReserved": "2024-08-08T14:28:37.978Z",
    "dateUpdated": "2024-08-09T14:49:47.340Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-7707
Vulnerability from cvelistv5
Published
2024-08-13 00:00
Modified
2024-08-14 16:11
Summary
A vulnerability was found in Tenda FH1206 02.03.01.35 and classified as critical. Affected by this issue is the function formSafeEmailFilter of the file /goform/SafeEmailFilter of the component HTTP POST Request Handler. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
https://vuldb.com/?id.274190vdb-entry, technical-description
https://vuldb.com/?ctiid.274190signature, permissions-required
https://vuldb.com/?submit.385670third-party-advisory
https://github.com/VodkaVortex/IoT/blob/main/formSafeEmailFilter.mdexploit
Impacted products
Vendor Product Version
Tenda FH1206 Version: 02.03.01.35
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:tenda:fh1206_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "fh1206_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "02.03.01.35"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-7707",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-14T16:02:09.859423Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-14T16:11:06.129Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "HTTP POST Request Handler"
          ],
          "product": "FH1206",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "02.03.01.35"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "Yangshuangning (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda FH1206 02.03.01.35 and classified as critical. Affected by this issue is the function formSafeEmailFilter of the file /goform/SafeEmailFilter of the component HTTP POST Request Handler. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda FH1206 02.03.01.35 gefunden. Sie wurde als kritisch eingestuft. Davon betroffen ist die Funktion formSafeEmailFilter der Datei /goform/SafeEmailFilter der Komponente HTTP POST Request Handler. Durch Manipulation des Arguments page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-13T00:00:07.511Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-274190 | Tenda FH1206 HTTP POST Request SafeEmailFilter formSafeEmailFilter stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.274190"
        },
        {
          "name": "VDB-274190 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.274190"
        },
        {
          "name": "Submit #385670 | Tenda FH1206 V02.03.01.35 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.385670"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/VodkaVortex/IoT/blob/main/formSafeEmailFilter.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-08-12T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-08-12T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-08-12T18:18:48.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda FH1206 HTTP POST Request SafeEmailFilter formSafeEmailFilter stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-7707",
    "datePublished": "2024-08-13T00:00:07.511Z",
    "dateReserved": "2024-08-12T16:13:45.110Z",
    "dateUpdated": "2024-08-14T16:11:06.129Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-42986
Vulnerability from cvelistv5
Published
2024-08-15 00:00
Modified
2024-10-24 19:45
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the PPPOEPassword parameter in the fromAdvSetWan function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:fh1206_firmware:02.03.01.35:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "fh1206_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "02.03.01.35"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-42986",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-19T20:39:01.763184Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-787",
                "description": "CWE-787 Out-of-bounds Write",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-24T19:45:22.676Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the PPPOEPassword parameter in the fromAdvSetWan function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-15T16:20:23.833789",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromAdvSetWan_PPPOEPassword.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-42986",
    "datePublished": "2024-08-15T00:00:00",
    "dateReserved": "2024-08-05T00:00:00",
    "dateUpdated": "2024-10-24T19:45:22.676Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-42987
Vulnerability from cvelistv5
Published
2024-08-15 00:00
Modified
2024-09-03 17:29
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the modino parameter in the fromPptpUserAdd function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:fh1206_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "fh1206_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "02.03.01.35"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-42987",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-03T17:28:29.730510Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-787",
                "description": "CWE-787 Out-of-bounds Write",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-03T17:29:43.534Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the modino parameter in the fromPptpUserAdd function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-15T16:20:23.088166",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromPptpUserAdd.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-42987",
    "datePublished": "2024-08-15T00:00:00",
    "dateReserved": "2024-08-05T00:00:00",
    "dateUpdated": "2024-09-03T17:29:43.534Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-42981
Vulnerability from cvelistv5
Published
2024-08-15 00:00
Modified
2024-08-16 17:37
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the delno parameter in the fromPptpUserSetting function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:fh1206_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "fh1206_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "v02.03.01.35"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-42981",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-16T17:35:44.895210Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-400",
                "description": "CWE-400 Uncontrolled Resource Consumption",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-16T17:37:55.127Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the delno parameter in the fromPptpUserSetting function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-15T16:20:29.183086",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromPptpUserSetting.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-42981",
    "datePublished": "2024-08-15T00:00:00",
    "dateReserved": "2024-08-05T00:00:00",
    "dateUpdated": "2024-08-16T17:37:55.127Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-42968
Vulnerability from cvelistv5
Published
2024-08-15 00:00
Modified
2024-08-15 17:30
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the Go parameter in the fromSafeUrlFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:fh1206_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "fh1206_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "02.03.01.35"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-42968",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-15T17:28:36.862715Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-15T17:30:11.935Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the Go parameter in the fromSafeUrlFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-15T16:20:37.708860",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromSafeMacFilter_Go.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-42968",
    "datePublished": "2024-08-15T00:00:00",
    "dateReserved": "2024-08-05T00:00:00",
    "dateUpdated": "2024-08-15T17:30:11.935Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-42978
Vulnerability from cvelistv5
Published
2024-08-15 00:00
Modified
2024-09-03 17:31
Severity ?
Summary
An issue in the handler function in /goform/telnet of Tenda FH1206 v02.03.01.35 allows attackers to execute arbitrary commands via a crafted HTTP request.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:fh1206_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "fh1206_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "02.03.01.35"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-42978",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-20T18:55:04.443940Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-03T17:31:07.209Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue in the handler function in /goform/telnet of Tenda FH1206 v02.03.01.35 allows attackers to execute arbitrary commands via a crafted HTTP request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-15T16:20:31.272730",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/telnet.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-42978",
    "datePublished": "2024-08-15T00:00:00",
    "dateReserved": "2024-08-05T00:00:00",
    "dateUpdated": "2024-09-03T17:31:07.209Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-42974
Vulnerability from cvelistv5
Published
2024-08-15 00:00
Modified
2024-08-15 17:52
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromwebExcptypemanFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:fh1206_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "fh1206_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "02.03.01.35"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-42974",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-15T17:51:40.998475Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-15T17:52:49.515Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromwebExcptypemanFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-15T16:20:35.732656",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromwebExcptypemanFilter.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-42974",
    "datePublished": "2024-08-15T00:00:00",
    "dateReserved": "2024-08-05T00:00:00",
    "dateUpdated": "2024-08-15T17:52:49.515Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-12002
Vulnerability from cvelistv5
Published
2024-11-30 13:00
Modified
2024-12-02 15:54
Summary
A vulnerability classified as problematic was found in Tenda FH451, FH1201, FH1202 and FH1206 up to 20241129. Affected by this vulnerability is the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
References
https://vuldb.com/?id.286417vdb-entry, technical-description
https://vuldb.com/?ctiid.286417signature, permissions-required
https://vuldb.com/?submit.453974third-party-advisory
https://github.com/Kalvin2077/tenda-fh-cveexploit
https://www.tenda.com.cn/product
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-12002",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-12-02T15:53:24.555896Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-12-02T15:54:21.033Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "FH451",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241129"
            }
          ]
        },
        {
          "product": "FH1201",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241129"
            }
          ]
        },
        {
          "product": "FH1202",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241129"
            }
          ]
        },
        {
          "product": "FH1206",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241129"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "Kalv1n2077 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as problematic was found in Tenda FH451, FH1201, FH1202 and FH1206 up to 20241129. Affected by this vulnerability is the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "In Tenda FH451, FH1201, FH1202 and FH1206 bis 20241129 wurde eine problematische Schwachstelle entdeckt. Betroffen ist die Funktion websReadEvent der Datei /goform/GetIPTV. Durch Beeinflussen des Arguments Content-Length mit unbekannten Daten kann eine null pointer dereference-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 4,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-476",
              "description": "NULL Pointer Dereference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-404",
              "description": "Denial of Service",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-30T13:00:14.751Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-286417 | Tenda FH451/FH1201/FH1202/FH1206 GetIPTV websReadEvent null pointer dereference",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.286417"
        },
        {
          "name": "VDB-286417 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.286417"
        },
        {
          "name": "Submit #453974 | Tenda FH451/FH1201/FH1202/FH1206 FH451-V1.0.0.9/FH451-V1.0.0.7/FH451-V1.0.0.5/FH1201-V1.2.0.14(408)_EN/FH1201-V1.2.0.8(8155)/FH1202-V1.2.0.14(408)/etc NULL Pointer Dereference",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.453974"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/Kalvin2077/tenda-fh-cve"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-11-29T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-11-29T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-11-29T16:54:22.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda FH451/FH1201/FH1202/FH1206 GetIPTV websReadEvent null pointer dereference"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-12002",
    "datePublished": "2024-11-30T13:00:14.751Z",
    "dateReserved": "2024-11-29T15:49:13.514Z",
    "dateUpdated": "2024-12-02T15:54:21.033Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-42979
Vulnerability from cvelistv5
Published
2024-08-15 00:00
Modified
2024-08-15 17:19
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the frmL7ProtForm function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:fh1206_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "fh1206_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "02.03.01.35"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-42979",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-15T17:09:20.843998Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-15T17:19:26.256Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the frmL7ProtForm function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-15T16:20:30.531302",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/frmL7ProtForm.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-42979",
    "datePublished": "2024-08-15T00:00:00",
    "dateReserved": "2024-08-05T00:00:00",
    "dateUpdated": "2024-08-15T17:19:26.256Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-44390
Vulnerability from cvelistv5
Published
2024-08-23 00:00
Modified
2024-08-23 16:53
Summary
Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the function formWrlsafeset.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:fh1206_firmware:1.2.0.8\\(8155\\)_en:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "fh1206_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "1.2.0.8\\(8155\\)_en"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-44390",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-23T16:53:12.497414Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-23T16:53:52.431Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the function formWrlsafeset."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-23T16:16:50.359597",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/GroundCTL2MajorTom/pocs/blob/main/tenda_FH1206_buffer_overflow8.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-44390",
    "datePublished": "2024-08-23T00:00:00",
    "dateReserved": "2024-08-21T00:00:00",
    "dateUpdated": "2024-08-23T16:53:52.431Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-42983
Vulnerability from cvelistv5
Published
2024-08-15 00:00
Modified
2024-08-15 17:59
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the pptpPPW parameter in the fromAdvSetWan function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:fh1206_firmware:02.03.01.35:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "fh1206_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "02.03.01.35"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-42983",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-15T17:27:17.930289Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-15T17:59:15.856Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the pptpPPW parameter in the fromAdvSetWan function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-15T16:20:25.768791",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromAdvSetWan_pptpPPW.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-42983",
    "datePublished": "2024-08-15T00:00:00",
    "dateReserved": "2024-08-05T00:00:00",
    "dateUpdated": "2024-08-15T17:59:15.856Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}