Vulnerabilites related to totolink - ex300_v2_firmware
cve-2021-43663
Vulnerability from cvelistv5
Published
2022-03-30 23:40
Modified
2024-08-04 04:03
Severity ?
Summary
totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component cloudupdate_check.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:03:08.611Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection1.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component cloudupdate_check."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-30T23:40:13",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection1.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-43663",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component cloudupdate_check."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection1.md",
              "refsource": "MISC",
              "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection1.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-43663",
    "datePublished": "2022-03-30T23:40:13",
    "dateReserved": "2021-11-15T00:00:00",
    "dateUpdated": "2024-08-04T04:03:08.611Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-43662
Vulnerability from cvelistv5
Published
2022-03-30 23:26
Modified
2024-08-04 04:03
Severity ?
Summary
totolink EX300_v2, ver V4.0.3c.140_B20210429 and A720R ,ver V4.1.5cu.470_B20200911 have an issue which causes uncontrolled resource consumption.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:03:08.137Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/dos.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "totolink EX300_v2, ver V4.0.3c.140_B20210429 and A720R ,ver V4.1.5cu.470_B20200911 have an issue which causes uncontrolled resource consumption."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-30T23:26:03",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/dos.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-43662",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "totolink EX300_v2, ver V4.0.3c.140_B20210429 and A720R ,ver V4.1.5cu.470_B20200911 have an issue which causes uncontrolled resource consumption."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/dos.md",
              "refsource": "MISC",
              "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/dos.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-43662",
    "datePublished": "2022-03-30T23:26:03",
    "dateReserved": "2021-11-15T00:00:00",
    "dateUpdated": "2024-08-04T04:03:08.137Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-43664
Vulnerability from cvelistv5
Published
2022-03-30 22:53
Modified
2024-08-04 04:03
Severity ?
Summary
totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component process forceugpo.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:03:08.641Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection2.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component process\u0026nbsp;forceugpo."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-30T22:53:59",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection2.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-43664",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component process\u0026nbsp;forceugpo."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection2.md",
              "refsource": "MISC",
              "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection2.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-43664",
    "datePublished": "2022-03-30T22:53:59",
    "dateReserved": "2021-11-15T00:00:00",
    "dateUpdated": "2024-08-04T04:03:08.641Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-25008
Vulnerability from cvelistv5
Published
2022-03-30 22:27
Modified
2024-08-03 04:29
Severity ?
Summary
totolink EX300_v2 V4.0.3c.140_B20210429 and EX1200T V4.1.2cu.5230_B20210706 does not contain an authentication mechanism.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:29:01.604Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/missing-authentication.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "totolink EX300_v2 V4.0.3c.140_B20210429 and EX1200T V4.1.2cu.5230_B20210706 does not contain an authentication mechanism."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-30T22:27:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/missing-authentication.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-25008",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "totolink EX300_v2 V4.0.3c.140_B20210429 and EX1200T V4.1.2cu.5230_B20210706 does not contain an authentication mechanism."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/missing-authentication.md",
              "refsource": "MISC",
              "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/missing-authentication.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-25008",
    "datePublished": "2022-03-30T22:27:00",
    "dateReserved": "2022-02-14T00:00:00",
    "dateUpdated": "2024-08-03T04:29:01.604Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-32449
Vulnerability from cvelistv5
Published
2022-07-07 00:00
Modified
2024-08-03 07:39
Severity ?
Summary
TOTOLINK EX300_V2 V4.0.3c.7484 was discovered to contain a command injection vulnerability via the langType parameter in the setLanguageCfg function. This vulnerability is exploitable via a crafted MQTT data packet.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T07:39:51.043Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/winmt/CVE/blob/main/TOTOLINK%20EX300_V2/README.md"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/winmt/my-vuls/tree/main/TOTOLINK%20EX300_V2"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "TOTOLINK EX300_V2 V4.0.3c.7484 was discovered to contain a command injection vulnerability via the langType parameter in the setLanguageCfg function. This vulnerability is exploitable via a crafted MQTT data packet."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-01T00:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/winmt/CVE/blob/main/TOTOLINK%20EX300_V2/README.md"
        },
        {
          "url": "https://github.com/winmt/my-vuls/tree/main/TOTOLINK%20EX300_V2"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-32449",
    "datePublished": "2022-07-07T00:00:00",
    "dateReserved": "2022-06-05T00:00:00",
    "dateUpdated": "2024-08-03T07:39:51.043Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-43661
Vulnerability from cvelistv5
Published
2022-03-30 23:19
Modified
2024-08-04 04:03
Severity ?
Summary
totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a reflected cross-site scripting (XSS) vulnerability via the component /home.asp.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:03:08.303Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/xss-vulnerability.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a reflected cross-site scripting (XSS) vulnerability via the component /home.asp."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-30T23:19:19",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/xss-vulnerability.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-43661",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a reflected cross-site scripting (XSS) vulnerability via the component /home.asp."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/xss-vulnerability.md",
              "refsource": "MISC",
              "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/xss-vulnerability.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-43661",
    "datePublished": "2022-03-30T23:19:19",
    "dateReserved": "2021-11-15T00:00:00",
    "dateUpdated": "2024-08-04T04:03:08.303Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Vulnerability from fkie_nvd
Published
2022-03-31 00:15
Modified
2024-11-21 06:29
Summary
totolink EX300_v2, ver V4.0.3c.140_B20210429 and A720R ,ver V4.1.5cu.470_B20200911 have an issue which causes uncontrolled resource consumption.
Impacted products
Vendor Product Version
totolink ex300_v2_firmware 4.0.3c.140_b20210429
totolink ex300_v2 -
totolink a720r_firmware 4.1.5cu.470_b20200911
totolink a720r -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:ex300_v2_firmware:4.0.3c.140_b20210429:*:*:*:*:*:*:*",
              "matchCriteriaId": "BD7185B4-C0DA-4EC1-B32E-6D4385A28BA4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:ex300_v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C7D15BE-D0FA-48C4-9752-F11255ABA2BA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:a720r_firmware:4.1.5cu.470_b20200911:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7B3C9D3-E762-4AEE-9E03-B2A1819785A4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:a720r:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1DE5168-B787-462C-B024-2B8F73759034",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "totolink EX300_v2, ver V4.0.3c.140_B20210429 and A720R ,ver V4.1.5cu.470_B20200911 have an issue which causes uncontrolled resource consumption."
    },
    {
      "lang": "es",
      "value": "totolink EX300_v2, versi\u00f3n V4.0.3c.140_B20210429 y A720R ,versi\u00f3n V4.1.5cu.470_B20200911, presentan un problema que causa un consumo no controlado de recursos"
    }
  ],
  "id": "CVE-2021-43662",
  "lastModified": "2024-11-21T06:29:34.157",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "ADJACENT_NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 3.3,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 6.5,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-03-31T00:15:07.987",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/dos.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/dos.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-770"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-03-31 00:15
Modified
2024-11-21 06:29
Summary
totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component cloudupdate_check.
Impacted products
Vendor Product Version
totolink ex300_v2_firmware 4.0.3c.140_b20210429
totolink ex300_v2 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:ex300_v2_firmware:4.0.3c.140_b20210429:*:*:*:*:*:*:*",
              "matchCriteriaId": "BD7185B4-C0DA-4EC1-B32E-6D4385A28BA4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:ex300_v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C7D15BE-D0FA-48C4-9752-F11255ABA2BA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component cloudupdate_check."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que totolink EX300_v2 versi\u00f3n V4.0.3c.140_B20210429, contiene una vulnerabilidad de inyecci\u00f3n de comandos por medio del componente cloudupdate_check"
    }
  ],
  "id": "CVE-2021-43663",
  "lastModified": "2024-11-21T06:29:34.317",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "ADJACENT_NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.9,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:A/AC:M/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 5.5,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.6,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-03-31T00:15:08.033",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection1.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection1.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-03-31 00:15
Modified
2024-11-21 06:29
Summary
totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a reflected cross-site scripting (XSS) vulnerability via the component /home.asp.
Impacted products
Vendor Product Version
totolink ex300_v2_firmware 4.0.3c.140_b20210429
totolink ex300_v2 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:ex300_v2_firmware:4.0.3c.140_b20210429:*:*:*:*:*:*:*",
              "matchCriteriaId": "BD7185B4-C0DA-4EC1-B32E-6D4385A28BA4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:ex300_v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C7D15BE-D0FA-48C4-9752-F11255ABA2BA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a reflected cross-site scripting (XSS) vulnerability via the component /home.asp."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que totolink EX300_v2 versi\u00f3n V4.0.3c.140_B20210429, contiene una vulnerabilidad de tipo cross-site scripting (XSS) reflejada por medio del componente /home.asp"
    }
  ],
  "id": "CVE-2021-43661",
  "lastModified": "2024-11-21T06:29:34.000",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 4.3,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.1,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-03-31T00:15:07.947",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/xss-vulnerability.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/xss-vulnerability.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-07-07 19:15
Modified
2024-11-21 07:06
Severity ?
Summary
TOTOLINK EX300_V2 V4.0.3c.7484 was discovered to contain a command injection vulnerability via the langType parameter in the setLanguageCfg function. This vulnerability is exploitable via a crafted MQTT data packet.
Impacted products
Vendor Product Version
totolink ex300_v2_firmware 4.0.3c.7484
totolink ex300_v2 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:ex300_v2_firmware:4.0.3c.7484:*:*:*:*:*:*:*",
              "matchCriteriaId": "803527FC-A921-40EB-BE58-2AAE37BEA697",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:ex300_v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C7D15BE-D0FA-48C4-9752-F11255ABA2BA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "TOTOLINK EX300_V2 V4.0.3c.7484 was discovered to contain a command injection vulnerability via the langType parameter in the setLanguageCfg function. This vulnerability is exploitable via a crafted MQTT data packet."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que TOTOLINK EX300_V2 versi\u00f3n V4.0.3c.7484, contiene una vulnerabilidad de inyecci\u00f3n de comandos por medio del par\u00e1metro langType en la funci\u00f3n setLanguageCfg. Esta vulnerabilidad es explotable por medio de un paquete de datos MQTT dise\u00f1ado"
    }
  ],
  "id": "CVE-2022-32449",
  "lastModified": "2024-11-21T07:06:22.550",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-07-07T19:15:08.350",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/winmt/CVE/blob/main/TOTOLINK%20EX300_V2/README.md"
    },
    {
      "source": "cve@mitre.org",
      "url": "https://github.com/winmt/my-vuls/tree/main/TOTOLINK%20EX300_V2"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/winmt/CVE/blob/main/TOTOLINK%20EX300_V2/README.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://github.com/winmt/my-vuls/tree/main/TOTOLINK%20EX300_V2"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-03-30 23:15
Modified
2024-11-21 06:29
Summary
totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component process forceugpo.
Impacted products
Vendor Product Version
totolink ex300_v2_firmware 4.0.3c.140_b20210429
totolink ex300_v2 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:ex300_v2_firmware:4.0.3c.140_b20210429:*:*:*:*:*:*:*",
              "matchCriteriaId": "BD7185B4-C0DA-4EC1-B32E-6D4385A28BA4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:ex300_v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C7D15BE-D0FA-48C4-9752-F11255ABA2BA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component process\u0026nbsp;forceugpo."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que totolink EX300_v2 versi\u00f3n V4.0.3c.140_B20210429, contiene una vulnerabilidad de inyecci\u00f3n de comandos por medio del componente process\u0026#xa0;forceugpo"
    }
  ],
  "id": "CVE-2021-43664",
  "lastModified": "2024-11-21T06:29:34.470",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.3,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.1,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.2,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-03-30T23:15:07.737",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection2.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection2.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-03-30 23:15
Modified
2024-11-21 06:51
Summary
totolink EX300_v2 V4.0.3c.140_B20210429 and EX1200T V4.1.2cu.5230_B20210706 does not contain an authentication mechanism.
Impacted products
Vendor Product Version
totolink ex300_v2_firmware 4.0.3c.140_b20210429
totolink ex300_v2 -
totolink ex1200t_firmware 4.1.2cu.5230_b20210706
totolink ex1200t -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:ex300_v2_firmware:4.0.3c.140_b20210429:*:*:*:*:*:*:*",
              "matchCriteriaId": "BD7185B4-C0DA-4EC1-B32E-6D4385A28BA4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:ex300_v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C7D15BE-D0FA-48C4-9752-F11255ABA2BA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:ex1200t_firmware:4.1.2cu.5230_b20210706:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0FD1F54-D54F-4038-AA4E-09F203FA7396",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:ex1200t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F262644E-2558-423E-A19E-7C86A1756FBF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "totolink EX300_v2 V4.0.3c.140_B20210429 and EX1200T V4.1.2cu.5230_B20210706 does not contain an authentication mechanism."
    },
    {
      "lang": "es",
      "value": "Totolink EX300_v2 versi\u00f3n V4.0.3c.140_B20210429 y EX1200T versi\u00f3n V4.1.2cu.5230_B20210706, no contienen un mecanismo de autenticaci\u00f3n"
    }
  ],
  "id": "CVE-2022-25008",
  "lastModified": "2024-11-21T06:51:32.073",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "ADJACENT_NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 6.5,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-03-30T23:15:08.093",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/missing-authentication.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/missing-authentication.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-306"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}