Vulnerabilites related to dlink - dir-3060_firmware
Vulnerability from fkie_nvd
Published
2022-11-18 17:15
Modified
2024-11-21 07:27
Severity ?
Summary
D-Link DIR3060 DIR3060A1_FW111B04.bin is vulnerable to Buffer Overflow.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/flamingo1616/iot_vuln/blob/main/D-Link/DIR-3060/5.md | Exploit, Third Party Advisory | |
cve@mitre.org | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/flamingo1616/iot_vuln/blob/main/D-Link/DIR-3060/5.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
dlink | dir-3060_firmware | 1.11b04 | |
dlink | dir-3060 | a1 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-3060_firmware:1.11b04:*:*:*:*:*:*:*", "matchCriteriaId": "8C423CCB-73CC-4AE7-B163-F2A0CB4D8817", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-3060:a1:*:*:*:*:*:*:*", "matchCriteriaId": "75CB7C7C-1B0E-4EC8-9FFC-363D2DF1CDBD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "D-Link DIR3060 DIR3060A1_FW111B04.bin is vulnerable to Buffer Overflow." }, { "lang": "es", "value": "D-Link DIR3060 DIR3060A1_FW111B04.bin es vulnerable al desbordamiento del b\u00fafer." } ], "id": "CVE-2022-44204", "lastModified": "2024-11-21T07:27:45.053", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-11-18T17:15:10.123", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/flamingo1616/iot_vuln/blob/main/D-Link/DIR-3060/5.md" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/flamingo1616/iot_vuln/blob/main/D-Link/DIR-3060/5.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.dlink.com/en/security-bulletin/" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2022-04-11 20:15
Modified
2024-11-21 06:40
Severity ?
Summary
A command injection vulnerability in the protest binary allows an attacker with access to the remote command line interface to execute arbitrary commands as root.
References
▼ | URL | Tags | |
---|---|---|---|
vulnreport@tenable.com | https://www.tenable.com/security/research/tra-2022-09 | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.tenable.com/security/research/tra-2022-09 | Exploit, Third Party Advisory |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-1360_firmware:1.02b03:*:*:*:*:*:*:*", "matchCriteriaId": "CF007E45-F1D5-4B86-8C32-4522BB78B113", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-1360_firmware:1.03b02:*:*:*:*:*:*:*", "matchCriteriaId": "9EE0B84B-984C-405B-AD53-89F048F48721", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-1360_firmware:1.11b04:*:*:*:*:*:*:*", "matchCriteriaId": "E091E879-E4C2-4782-9E47-C712A7947727", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-1360:a1:*:*:*:*:*:*:*", "matchCriteriaId": "C8E7C9EC-241F-4698-9878-DC02CB1B69E2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-1760_firmware:1.01b04:*:*:*:*:*:*:*", "matchCriteriaId": "CA7235AB-E767-4772-99F4-2CC3046564EC", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-1760_firmware:1.11b03:beta:*:*:*:*:*:*", "matchCriteriaId": "D6FEFE51-389C-478A-B2D5-AAF2066649C4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-1760:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C961D12-61B7-440A-B7CE-C431E6903CDC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-1960_firmware:1.02b01:*:*:*:*:*:*:*", "matchCriteriaId": "94032F8E-AB47-451C-B5C2-21724ABB43DE", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-1960_firmware:1.03b03:*:*:*:*:*:*:*", "matchCriteriaId": "4292CE32-F5C9-4714-AE2E-577C304EA441", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-1960_firmware:1.11b03:*:*:*:*:*:*:*", "matchCriteriaId": "490294F3-F68E-43A4-8570-A4BDF233BEED", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-1960:a1:*:*:*:*:*:*:*", "matchCriteriaId": "144284ED-C086-49DE-8516-844A6CD2A30C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-2640_firmware:1.11b02:beta:*:*:*:*:*:*", "matchCriteriaId": "9141FC19-E6B2-4BA3-9166-A173BF772A6E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-2640:-:*:*:*:*:*:*:*", "matchCriteriaId": "D68A4D09-6C9A-4F3B-863D-DF612DB8DB89", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-2660_firmware:1.04b03:*:*:*:*:*:*:*", "matchCriteriaId": "03EB40C9-7AA1-4850-8856-A10D0A4759D2", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-2660_firmware:1.11b04:*:*:*:*:*:*:*", "matchCriteriaId": "F695ADF7-0327-4983-A4E2-174C15674B37", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-2660:a1:*:*:*:*:*:*:*", "matchCriteriaId": "D043D251-10DA-4939-BEBA-284A4A956B0D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-3040_firmware:1.13b03:beta:*:*:*:*:*:*", "matchCriteriaId": "22A3B1DF-2D8E-4709-A7FA-8EAD016DA9F6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-3040:-:*:*:*:*:*:*:*", "matchCriteriaId": "A4EDA686-7BB6-49CB-8370-E0E5F53914A8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-3060_firmware:1.00b12:*:*:*:*:*:*:*", "matchCriteriaId": "335C34AB-4223-4D81-B664-C0E730B0BFBA", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-3060_firmware:1.11b04:beta:*:*:*:*:*:*", "matchCriteriaId": "BE1DF67D-9464-4FEA-A5F6-BD5AC47D4E2F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-3060:-:*:*:*:*:*:*:*", "matchCriteriaId": "1B48DF58-000E-4846-BEB6-69E4E69375E7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-867_firmware:1.20b10:*:*:*:*:*:*:*", "matchCriteriaId": "12D2E414-7BC6-432D-897B-35FFAE944374", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-867:a1:*:*:*:*:*:*:*", "matchCriteriaId": "9747CBE7-1ECC-403F-93FC-0BBBE0124111", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-878_firmware:1.20b05:*:*:*:*:*:*:*", "matchCriteriaId": "D1CD2BE2-2157-4ADA-986F-2033EF15BC56", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-878_firmware:1.30b08:*:*:*:*:*:*:*", "matchCriteriaId": "7BFB6A28-3330-449A-A738-C2AC52B04C6B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-878:-:*:*:*:*:*:*:*", "matchCriteriaId": "9D288C73-F89A-47FF-AF11-143C3DFDF942", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-882_firmware:1.20b06:*:*:*:*:*:*:*", "matchCriteriaId": "DEBD8322-35F5-40FC-B8F7-1C74AD9C6259", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-882:-:*:*:*:*:*:*:*", "matchCriteriaId": "F6ECB8ED-F3A2-4C05-8570-719ECB166B09", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-1360_firmware:1.00b15:*:*:*:*:*:*:*", "matchCriteriaId": "CD10B74D-AE8C-40EC-99E5-2298A3085840", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-1360_firmware:1.01b03:*:*:*:*:*:*:*", "matchCriteriaId": "7C7BF035-A533-4F38-9E4F-04A83D648B20", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-1360_firmware:1.11b04:beta:*:*:*:*:*:*", "matchCriteriaId": "37851FB0-40E6-4BA7-9A9C-E127851E4032", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-1360:-:*:*:*:*:*:*:*", "matchCriteriaId": "CD91DDBE-83E8-4F3A-BB71-1EC8798DD086", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-1960_firmware:1.11b03:beta:*:*:*:*:*:*", "matchCriteriaId": "97E30469-D830-457F-B1FD-7BA3DA8B49E3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-1960:-:*:*:*:*:*:*:*", "matchCriteriaId": "67D40051-D7D8-4C76-B006-A94D501647C6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-2640_firmware:1.01b04:*:*:*:*:*:*:*", "matchCriteriaId": "114D694E-3858-4FCA-BE67-65C78256C0FF", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-2640_firmware:1.11b02:*:*:*:*:*:*:*", "matchCriteriaId": "AC690F1B-7B27-42A1-853A-EF04959FCF07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-2640:a1:*:*:*:*:*:*:*", "matchCriteriaId": "F950267C-AA12-4B1B-9995-66CDB0512757", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-2660_firmware:1.00b14:*:*:*:*:*:*:*", "matchCriteriaId": "50F1ACBB-BE31-4912-862D-05866A0AD7C5", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-2660_firmware:1.01b03:*:*:*:*:*:*:*", "matchCriteriaId": "900238FF-5D28-4EF3-B8D2-92D9525EAF62", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-2660_firmware:1.02b01:*:*:*:*:*:*:*", "matchCriteriaId": "2BAB44B3-A735-4BAA-89E4-11EAB2E62EBF", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-2660_firmware:1.03b04:*:*:*:*:*:*:*", "matchCriteriaId": "2C4EF06F-6619-4523-977A-0A3780D65C08", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-2660_firmware:1.11b04:beta:*:*:*:*:*:*", "matchCriteriaId": "4B621EA3-5396-4E84-A2FA-0DB68CEE4583", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-2660:-:*:*:*:*:*:*:*", "matchCriteriaId": "37C4E9FB-B4B0-40A8-A0B0-398050F9180D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-3040_firmware:1.11b02:*:*:*:*:*:*:*", "matchCriteriaId": "536F60AF-6A0B-419A-B2EC-E13D6D7FC398", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-3040_firmware:1.12b01:*:*:*:*:*:*:*", "matchCriteriaId": "F5681FB5-5F16-439F-B40E-A5FBBF15DEE5", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-3040_firmware:1.13b03:*:*:*:*:*:*:*", "matchCriteriaId": "8495556A-FE73-4D22-A3F1-367D0D143DBD", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-3040_firmware:1.20b03:*:*:*:*:*:*:*", "matchCriteriaId": "8E2AA7D0-1625-4493-8E18-3B9362466C9B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-3040:a1:*:*:*:*:*:*:*", "matchCriteriaId": "05ACD014-D3EE-4653-91F9-959FB7BD0BC9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-3060_firmware:1.01b07:*:*:*:*:*:*:*", "matchCriteriaId": "26AA9A9D-4690-47C4-AB35-36FF8CD1E887", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-3060_firmware:1.02b03:*:*:*:*:*:*:*", "matchCriteriaId": "3B39D8AC-04D7-40AF-A72D-5ADD5CACA57A", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-3060_firmware:1.11b02:*:*:*:*:*:*:*", "matchCriteriaId": "16BC242D-9BBA-4A67-BCBD-A61CEBC87175", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-3060_firmware:1.11b04:*:*:*:*:*:*:*", "matchCriteriaId": "8C423CCB-73CC-4AE7-B163-F2A0CB4D8817", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-3060:a1:*:*:*:*:*:*:*", "matchCriteriaId": "75CB7C7C-1B0E-4EC8-9FFC-363D2DF1CDBD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-867_firmware:1.10b04:*:*:*:*:*:*:*", "matchCriteriaId": "2C531C05-7DE4-496D-B70B-8EEF56579BF9", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-867_firmware:1.30b07:*:*:*:*:*:*:*", "matchCriteriaId": "06D97D1B-02AC-46A2-AABC-6336B606C131", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-867:-:*:*:*:*:*:*:*", "matchCriteriaId": "94CB6320-D2FB-4405-8C2D-BB59798A0670", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-882_firmware:1.30b06:*:*:*:*:*:*:*", "matchCriteriaId": "ECEECA9D-716E-4C4D-A299-F3BA3D0C790B", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-882_firmware:1.30b10:*:*:*:*:*:*:*", "matchCriteriaId": "E29C868C-B1AD-4C46-99C4-94EEE89CF02A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-882:a1:*:*:*:*:*:*:*", "matchCriteriaId": "90575122-CE47-42E5-BCE3-6444599B16B3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A command injection vulnerability in the protest binary allows an attacker with access to the remote command line interface to execute arbitrary commands as root." }, { "lang": "es", "value": "Una vulnerabilidad de inyecci\u00f3n de comandos en el binario de protesta permite a un atacante con acceso a la interfaz de l\u00ednea de comandos remota ejecutar comandos arbitrarios como root" } ], "id": "CVE-2022-1262", "lastModified": "2024-11-21T06:40:21.910", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-04-11T20:15:18.157", "references": [ { "source": "vulnreport@tenable.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://www.tenable.com/security/research/tra-2022-09" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://www.tenable.com/security/research/tra-2022-09" } ], "sourceIdentifier": "vulnreport@tenable.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-03-11 17:15
Modified
2024-11-21 05:59
Severity ?
Summary
prog.cgi on D-Link DIR-3060 devices before 1.11b04 HF2 allows remote authenticated users to inject arbitrary commands in an admin or root context because SetVirtualServerSettings calls CheckArpTables, which calls popen unsafely.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
dlink | dir-3060_firmware | * | |
dlink | dir-3060 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-3060_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FCA4E213-3136-41ED-B9D9-D9F8C90E46D1", "versionEndIncluding": "1.11b04", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-3060:-:*:*:*:*:*:*:*", "matchCriteriaId": "1B48DF58-000E-4846-BEB6-69E4E69375E7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "prog.cgi on D-Link DIR-3060 devices before 1.11b04 HF2 allows remote authenticated users to inject arbitrary commands in an admin or root context because SetVirtualServerSettings calls CheckArpTables, which calls popen unsafely." }, { "lang": "es", "value": "El archivo prog.cgi en los dispositivos D-Link DIR-3060 versiones anteriores a 1.11b04 HF2, permite a usuarios autenticados remoto inyectar comandos arbitrarios en un contexto de administrador o root porque la funci\u00f3n SetVirtualServerSettings llama a CheckArpTables, que llama a popen de manera no segura" } ], "id": "CVE-2021-28144", "lastModified": "2024-11-21T05:59:10.403", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-11T17:15:13.330", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory", "VDB Entry" ], "url": "http://packetstormsecurity.com/files/161757/D-Link-DIR-3060-1.11b04-Command-Injection.html" }, { "source": "cve@mitre.org", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "http://seclists.org/fulldisclosure/2021/Mar/23" }, { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10208" }, { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://www.iot-inspector.com/blog/advisory-d-link-dir-3060/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory", "VDB Entry" ], "url": "http://packetstormsecurity.com/files/161757/D-Link-DIR-3060-1.11b04-Command-Injection.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "http://seclists.org/fulldisclosure/2021/Mar/23" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10208" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://www.iot-inspector.com/blog/advisory-d-link-dir-3060/" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
cve-2022-44204
Vulnerability from cvelistv5
Published
2022-11-18 00:00
Modified
2024-08-03 13:47
Severity ?
EPSS score ?
Summary
D-Link DIR3060 DIR3060A1_FW111B04.bin is vulnerable to Buffer Overflow.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T13:47:05.692Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "tags": [ "x_transferred" ], "url": "https://github.com/flamingo1616/iot_vuln/blob/main/D-Link/DIR-3060/5.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "D-Link DIR3060 DIR3060A1_FW111B04.bin is vulnerable to Buffer Overflow." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-11-18T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://www.dlink.com/en/security-bulletin/" }, { "url": "https://github.com/flamingo1616/iot_vuln/blob/main/D-Link/DIR-3060/5.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-44204", "datePublished": "2022-11-18T00:00:00", "dateReserved": "2022-10-30T00:00:00", "dateUpdated": "2024-08-03T13:47:05.692Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-1262
Vulnerability from cvelistv5
Published
2022-04-11 19:38
Modified
2024-08-02 23:55
Severity ?
EPSS score ?
Summary
A command injection vulnerability in the protest binary allows an attacker with access to the remote command line interface to execute arbitrary commands as root.
References
▼ | URL | Tags |
---|---|---|
https://www.tenable.com/security/research/tra-2022-09 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | D-Link Routers |
Version: DIR-1360 A1 firmware version 1.02B03, DIR-1360 A1 firmware version 1.03B02, DIR-1360 A1 firmware version 1.11B04, DIR-1360 firmware version 1.00B15, DIR-1360 firmware version 1.01B03, DIR-1760 firmware version 1.01B04, DIR-1960 A1 firmware version 1.02B01, DIR-1960 A1 firmware version 1.03B03, DIR-1960 A1 firmware version 1.11B03, DIR-2640 A1 firmware version 1.01B04, DIR-2640 A1 firmware version 1.11B02, DIR-2660 A1 firmware version 1.04B03, DIR-2660 A1 firmware version 1.11B04, DIR-2660 firmware version 1.00B14, DIR-2660 firmware version 1.01B03, DIR-2660 firmware version 1.02B01, DIR-2660 firmware version 1.03B04, DIR-3040 A1 firmware version 1.11B02, DIR-3040 A1 firmware version 1.12B01, DIR-3040 A1 firmware version 1.13B03, DIR-3040 A1 firmware version 1.20B03, DIR-3060 A1 firmware version 1.01B07, DIR-3060 A1 firmware version 1.02B03, DIR-3060 A1 firmware version 1.11B04, DIR-3060 firmware version 1.00B12, DIR-867 A1 firmware version 1.20B10, DIR-867 firmware version 1.10B04, DIR-867 fir ...[truncated*] |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T23:55:24.531Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.tenable.com/security/research/tra-2022-09" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "D-Link Routers", "vendor": "n/a", "versions": [ { "status": "affected", "version": "DIR-1360 A1 firmware version 1.02B03, DIR-1360 A1 firmware version 1.03B02, DIR-1360 A1 firmware version 1.11B04, DIR-1360 firmware version 1.00B15, DIR-1360 firmware version 1.01B03, DIR-1760 firmware version 1.01B04, DIR-1960 A1 firmware version 1.02B01, DIR-1960 A1 firmware version 1.03B03, DIR-1960 A1 firmware version 1.11B03, DIR-2640 A1 firmware version 1.01B04, DIR-2640 A1 firmware version 1.11B02, DIR-2660 A1 firmware version 1.04B03, DIR-2660 A1 firmware version 1.11B04, DIR-2660 firmware version 1.00B14, DIR-2660 firmware version 1.01B03, DIR-2660 firmware version 1.02B01, DIR-2660 firmware version 1.03B04, DIR-3040 A1 firmware version 1.11B02, DIR-3040 A1 firmware version 1.12B01, DIR-3040 A1 firmware version 1.13B03, DIR-3040 A1 firmware version 1.20B03, DIR-3060 A1 firmware version 1.01B07, DIR-3060 A1 firmware version 1.02B03, DIR-3060 A1 firmware version 1.11B04, DIR-3060 firmware version 1.00B12, DIR-867 A1 firmware version 1.20B10, DIR-867 firmware version 1.10B04, DIR-867 fir ...[truncated*]" } ] } ], "descriptions": [ { "lang": "en", "value": "A command injection vulnerability in the protest binary allows an attacker with access to the remote command line interface to execute arbitrary commands as root." } ], "problemTypes": [ { "descriptions": [ { "description": "Command Injection", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-04-11T19:38:13", "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be", "shortName": "tenable" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.tenable.com/security/research/tra-2022-09" } ], "x_ConverterErrors": { "version_name": { "error": "version_name too long. Use array of versions to record more than one version.", "message": "Truncated!" } }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "vulnreport@tenable.com", "ID": "CVE-2022-1262", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "D-Link Routers", "version": { "version_data": [ { "version_value": "DIR-1360 A1 firmware version 1.02B03, DIR-1360 A1 firmware version 1.03B02, DIR-1360 A1 firmware version 1.11B04, DIR-1360 firmware version 1.00B15, DIR-1360 firmware version 1.01B03, DIR-1760 firmware version 1.01B04, DIR-1960 A1 firmware version 1.02B01, DIR-1960 A1 firmware version 1.03B03, DIR-1960 A1 firmware version 1.11B03, DIR-2640 A1 firmware version 1.01B04, DIR-2640 A1 firmware version 1.11B02, DIR-2660 A1 firmware version 1.04B03, DIR-2660 A1 firmware version 1.11B04, DIR-2660 firmware version 1.00B14, DIR-2660 firmware version 1.01B03, DIR-2660 firmware version 1.02B01, DIR-2660 firmware version 1.03B04, DIR-3040 A1 firmware version 1.11B02, DIR-3040 A1 firmware version 1.12B01, DIR-3040 A1 firmware version 1.13B03, DIR-3040 A1 firmware version 1.20B03, DIR-3060 A1 firmware version 1.01B07, DIR-3060 A1 firmware version 1.02B03, DIR-3060 A1 firmware version 1.11B04, DIR-3060 firmware version 1.00B12, DIR-867 A1 firmware version 1.20B10, DIR-867 firmware version 1.10B04, DIR-867 firmware version 1.30B07, DIR-878 firmware version 1.20B05, DIR-878 firmware version 1.30B08, DIR-882 A1 firmware version 1.30B06, DIR-882 A1 firmware version 1.30B10, DIR-882 firmware version 1.20B06" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A command injection vulnerability in the protest binary allows an attacker with access to the remote command line interface to execute arbitrary commands as root." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Command Injection" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.tenable.com/security/research/tra-2022-09", "refsource": "MISC", "url": "https://www.tenable.com/security/research/tra-2022-09" } ] } } } }, "cveMetadata": { "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be", "assignerShortName": "tenable", "cveId": "CVE-2022-1262", "datePublished": "2022-04-11T19:38:13", "dateReserved": "2022-04-06T00:00:00", "dateUpdated": "2024-08-02T23:55:24.531Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-28144
Vulnerability from cvelistv5
Published
2021-03-11 16:02
Modified
2024-08-03 21:33
Severity ?
EPSS score ?
Summary
prog.cgi on D-Link DIR-3060 devices before 1.11b04 HF2 allows remote authenticated users to inject arbitrary commands in an admin or root context because SetVirtualServerSettings calls CheckArpTables, which calls popen unsafely.
References
▼ | URL | Tags |
---|---|---|
https://www.iot-inspector.com/blog/advisory-d-link-dir-3060/ | x_refsource_MISC | |
https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10208 | x_refsource_CONFIRM | |
http://seclists.org/fulldisclosure/2021/Mar/23 | mailing-list, x_refsource_FULLDISC | |
http://packetstormsecurity.com/files/161757/D-Link-DIR-3060-1.11b04-Command-Injection.html | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T21:33:17.527Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.iot-inspector.com/blog/advisory-d-link-dir-3060/" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10208" }, { "name": "20210311 [CVE-2021-28144] Authenticated Command Injection in D-Link DIR-3060 Web Interface", "tags": [ "mailing-list", "x_refsource_FULLDISC", "x_transferred" ], "url": "http://seclists.org/fulldisclosure/2021/Mar/23" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://packetstormsecurity.com/files/161757/D-Link-DIR-3060-1.11b04-Command-Injection.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "prog.cgi on D-Link DIR-3060 devices before 1.11b04 HF2 allows remote authenticated users to inject arbitrary commands in an admin or root context because SetVirtualServerSettings calls CheckArpTables, which calls popen unsafely." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-12T17:06:24", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.iot-inspector.com/blog/advisory-d-link-dir-3060/" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10208" }, { "name": "20210311 [CVE-2021-28144] Authenticated Command Injection in D-Link DIR-3060 Web Interface", "tags": [ "mailing-list", "x_refsource_FULLDISC" ], "url": "http://seclists.org/fulldisclosure/2021/Mar/23" }, { "tags": [ "x_refsource_MISC" ], "url": "http://packetstormsecurity.com/files/161757/D-Link-DIR-3060-1.11b04-Command-Injection.html" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-28144", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "prog.cgi on D-Link DIR-3060 devices before 1.11b04 HF2 allows remote authenticated users to inject arbitrary commands in an admin or root context because SetVirtualServerSettings calls CheckArpTables, which calls popen unsafely." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.iot-inspector.com/blog/advisory-d-link-dir-3060/", "refsource": "MISC", "url": "https://www.iot-inspector.com/blog/advisory-d-link-dir-3060/" }, { "name": "https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10208", "refsource": "CONFIRM", "url": "https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10208" }, { "name": "20210311 [CVE-2021-28144] Authenticated Command Injection in D-Link DIR-3060 Web Interface", "refsource": "FULLDISC", "url": "http://seclists.org/fulldisclosure/2021/Mar/23" }, { "name": "http://packetstormsecurity.com/files/161757/D-Link-DIR-3060-1.11b04-Command-Injection.html", "refsource": "MISC", "url": "http://packetstormsecurity.com/files/161757/D-Link-DIR-3060-1.11b04-Command-Injection.html" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-28144", "datePublished": "2021-03-11T16:02:05", "dateReserved": "2021-03-11T00:00:00", "dateUpdated": "2024-08-03T21:33:17.527Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }