Vulnerabilites related to dlink - dir-3040
var-202107-0569
Vulnerability from variot
A code execution vulnerability exists in the Libcli Test Environment functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to arbitrary command execution. An attacker can send a sequence of requests to trigger this vulnerability. D-LINK DIR-3040 Contains an unspecified vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. D-LINK DIR-3040 is a router of D-Link company in Taiwan, China, which provides the function of connecting to the network. No detailed vulnerability details are currently provided. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202107-0569", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "dir-3040", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.13b03" }, { "model": "dir-3040", "scope": "eq", "trust": 0.8, "vendor": "d link", "version": null }, { "model": "dir-3040", "scope": "eq", "trust": 0.8, "vendor": "d link", "version": "dir-3040 firmware 1.13b03" }, { "model": "d-link dir-3040 1.13b03", "scope": null, "trust": 0.6, "vendor": "dlink", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-53340" }, { "db": "JVNDB", "id": "JVNDB-2021-009661" }, { "db": "NVD", "id": "CVE-2021-21819" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Discovered by Dave McDaniel of Cisco Talos.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202107-1116" } ], "trust": 0.6 }, "cve": "CVE-2021-21819", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "CVE-2021-21819", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 1.0, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 6.5, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-21819", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "MULTIPLE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 6.4, "id": "CNVD-2021-53340", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.2, "id": "CVE-2021-21819", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "talos-cna@cisco.com", "availabilityImpact": "HIGH", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.3, "id": "CVE-2021-21819", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.2, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-21819", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-21819", "trust": 1.0, "value": "HIGH" }, { "author": "talos-cna@cisco.com", "id": "CVE-2021-21819", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2021-21819", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-53340", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202107-1116", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-21819", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-53340" }, { "db": "VULMON", "id": "CVE-2021-21819" }, { "db": "JVNDB", "id": "JVNDB-2021-009661" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-1116" }, { "db": "NVD", "id": "CVE-2021-21819" }, { "db": "NVD", "id": "CVE-2021-21819" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A code execution vulnerability exists in the Libcli Test Environment functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to arbitrary command execution. An attacker can send a sequence of requests to trigger this vulnerability. D-LINK DIR-3040 Contains an unspecified vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. D-LINK DIR-3040 is a router of D-Link company in Taiwan, China, which provides the function of connecting to the network. No detailed vulnerability details are currently provided. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements", "sources": [ { "db": "NVD", "id": "CVE-2021-21819" }, { "db": "JVNDB", "id": "JVNDB-2021-009661" }, { "db": "CNVD", "id": "CNVD-2021-53340" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "VULMON", "id": "CVE-2021-21819" } ], "trust": 2.79 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-21819", "trust": 3.9 }, { "db": "TALOS", "id": "TALOS-2021-1284", "trust": 3.1 }, { "db": "JVNDB", "id": "JVNDB-2021-009661", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-53340", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021041363", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021071610", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202107-1116", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-21819", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-53340" }, { "db": "VULMON", "id": "CVE-2021-21819" }, { "db": "JVNDB", "id": "JVNDB-2021-009661" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-1116" }, { "db": "NVD", "id": "CVE-2021-21819" } ] }, "id": "VAR-202107-0569", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-53340" } ], "trust": 1.222051285 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-53340" } ] }, "last_update_date": "2024-08-14T12:08:11.565000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top\u00a0Page", "trust": 0.8, "url": "https://www.dlink.com.br/" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-009661" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-78", "trust": 1.0 }, { "problemtype": "Lack of information (CWE-noinfo) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-009661" }, { "db": "NVD", "id": "CVE-2021-21819" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.7, "url": "https://talosintelligence.com/vulnerability_reports/talos-2021-1284" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-21819" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021071610" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-53340" }, { "db": "VULMON", "id": "CVE-2021-21819" }, { "db": "JVNDB", "id": "JVNDB-2021-009661" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-1116" }, { "db": "NVD", "id": "CVE-2021-21819" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-53340" }, { "db": "VULMON", "id": "CVE-2021-21819" }, { "db": "JVNDB", "id": "JVNDB-2021-009661" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-1116" }, { "db": "NVD", "id": "CVE-2021-21819" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-07-22T00:00:00", "db": "CNVD", "id": "CNVD-2021-53340" }, { "date": "2021-07-16T00:00:00", "db": "VULMON", "id": "CVE-2021-21819" }, { "date": "2022-05-17T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-009661" }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-07-15T00:00:00", "db": "CNNVD", "id": "CNNVD-202107-1116" }, { "date": "2021-07-16T11:15:10.003000", "db": "NVD", "id": "CVE-2021-21819" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-07-22T00:00:00", "db": "CNVD", "id": "CNVD-2021-53340" }, { "date": "2021-07-22T00:00:00", "db": "VULMON", "id": "CVE-2021-21819" }, { "date": "2022-05-17T02:23:00", "db": "JVNDB", "id": "JVNDB-2021-009661" }, { "date": "2021-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2022-08-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202107-1116" }, { "date": "2022-07-29T14:52:24.497000", "db": "NVD", "id": "CVE-2021-21819" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202107-1116" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "D-LINK\u00a0DIR-3040\u00a0 Vulnerability in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-009661" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-975" } ], "trust": 0.6 } }
var-202212-1497
Vulnerability from variot
D-Link DIR-3040 device with firmware 120B03 was discovered to contain a command injection vulnerability via the SetTriggerLEDBlink function. D-Link Systems, Inc. (DoS) It may be in a state. D-Link DIR-3040 is a router of D-Link company in China. Provides the ability to connect to the network. The vulnerability stems from the failure of the SetTriggerLEDBlink function to correctly filter special characters and commands in the construction command. Attackers can use this vulnerability to cause arbitrary command execution
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202212-1497", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "dir-3040", "scope": null, "trust": 1.4, "vendor": "d link", "version": null }, { "model": "dir-3040", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "120b03" }, { "model": "dir-3040", "scope": "eq", "trust": 0.8, "vendor": "d link", "version": "dir-3040 firmware 120b03" }, { "model": "dir-3040", "scope": "eq", "trust": 0.8, "vendor": "d link", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-28115" }, { "db": "JVNDB", "id": "JVNDB-2022-023423" }, { "db": "NVD", "id": "CVE-2022-44832" } ] }, "cve": "CVE-2022-44832", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2023-28115", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2022-44832", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2022-44832", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2022-44832", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2022-44832", "trust": 0.8, "value": "Critical" }, { "author": "CNVD", "id": "CNVD-2023-28115", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202212-3268", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-28115" }, { "db": "JVNDB", "id": "JVNDB-2022-023423" }, { "db": "CNNVD", "id": "CNNVD-202212-3268" }, { "db": "NVD", "id": "CVE-2022-44832" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "D-Link DIR-3040 device with firmware 120B03 was discovered to contain a command injection vulnerability via the SetTriggerLEDBlink function. D-Link Systems, Inc. (DoS) It may be in a state. D-Link DIR-3040 is a router of D-Link company in China. Provides the ability to connect to the network. The vulnerability stems from the failure of the SetTriggerLEDBlink function to correctly filter special characters and commands in the construction command. Attackers can use this vulnerability to cause arbitrary command execution", "sources": [ { "db": "NVD", "id": "CVE-2022-44832" }, { "db": "JVNDB", "id": "JVNDB-2022-023423" }, { "db": "CNVD", "id": "CNVD-2023-28115" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-44832", "trust": 3.8 }, { "db": "JVNDB", "id": "JVNDB-2022-023423", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-28115", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202212-3268", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-28115" }, { "db": "JVNDB", "id": "JVNDB-2022-023423" }, { "db": "CNNVD", "id": "CNNVD-202212-3268" }, { "db": "NVD", "id": "CVE-2022-44832" } ] }, "id": "VAR-202212-1497", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-28115" } ], "trust": 0.84410257 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-28115" } ] }, "last_update_date": "2024-08-14T14:02:11.579000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-023423" }, { "db": "NVD", "id": "CVE-2022-44832" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.0, "url": "https://www.dlink.com/en/security-bulletin/" }, { "trust": 2.4, "url": "https://github.com/flamingo1616/iot_vuln/blob/main/d-link/dir-3040/6.md" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-44832" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-44832/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-28115" }, { "db": "JVNDB", "id": "JVNDB-2022-023423" }, { "db": "CNNVD", "id": "CNNVD-202212-3268" }, { "db": "NVD", "id": "CVE-2022-44832" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-28115" }, { "db": "JVNDB", "id": "JVNDB-2022-023423" }, { "db": "CNNVD", "id": "CNNVD-202212-3268" }, { "db": "NVD", "id": "CVE-2022-44832" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-17T00:00:00", "db": "CNVD", "id": "CNVD-2023-28115" }, { "date": "2023-11-29T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-023423" }, { "date": "2022-12-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202212-3268" }, { "date": "2022-12-14T15:15:10.467000", "db": "NVD", "id": "CVE-2022-44832" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-17T00:00:00", "db": "CNVD", "id": "CNVD-2023-28115" }, { "date": "2023-11-29T01:06:00", "db": "JVNDB", "id": "JVNDB-2022-023423" }, { "date": "2022-12-19T00:00:00", "db": "CNNVD", "id": "CNNVD-202212-3268" }, { "date": "2022-12-16T20:22:35.763000", "db": "NVD", "id": "CVE-2022-44832" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202212-3268" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "D-Link DIR-3040 Command Injection Vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2023-28115" }, { "db": "CNNVD", "id": "CNNVD-202212-3268" } ], "trust": 1.2 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202212-3268" } ], "trust": 0.6 } }
var-202301-1377
Vulnerability from variot
This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of D-Link DIR-3040 1.20B03 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the MiniDLNA service. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the MiniDLNA service. Was ZDI-CAN-19910. D-Link Systems, Inc. of DIR-3040 A heap-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. D-Link DIR-3040 is a router of D-Link company in China. Provides the ability to connect to the network
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202301-1377", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "dir-3040", "scope": null, "trust": 1.5, "vendor": "d link", "version": null }, { "model": "dir-3040", "scope": "lte", "trust": 1.0, "vendor": "dlink", "version": "1.20b03" }, { "model": "dir-3040", "scope": "eq", "trust": 0.8, "vendor": "d link", "version": null }, { "model": "dir-3040", "scope": "lte", "trust": 0.8, "vendor": "d link", "version": "dir-3040 firmware 1.20b03 and earlier" }, { "model": "dir-3040 \u003c=v1.20b03", "scope": null, "trust": 0.6, "vendor": "d link", "version": null } ], "sources": [ { "db": "ZDI", "id": "ZDI-23-052" }, { "db": "CNVD", "id": "CNVD-2023-27674" }, { "db": "JVNDB", "id": "JVNDB-2022-022047" }, { "db": "NVD", "id": "CVE-2022-43648" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Nicholas Zubrisky", "sources": [ { "db": "ZDI", "id": "ZDI-23-052" } ], "trust": 0.7 }, "cve": "CVE-2022-43648", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 6.5, "id": "CNVD-2023-27674", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "zdi-disclosures@trendmicro.com", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2022-43648", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.8, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2022-43648", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "ZDI", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2022-43648", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 0.7, "userInteraction": "NONE", "vectorString": "AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "zdi-disclosures@trendmicro.com", "id": "CVE-2022-43648", "trust": 1.0, "value": "HIGH" }, { "author": "nvd@nist.gov", "id": "CVE-2022-43648", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2022-43648", "trust": 0.8, "value": "High" }, { "author": "ZDI", "id": "CVE-2022-43648", "trust": 0.7, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2023-27674", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202303-2507", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "ZDI", "id": "ZDI-23-052" }, { "db": "CNVD", "id": "CNVD-2023-27674" }, { "db": "JVNDB", "id": "JVNDB-2022-022047" }, { "db": "CNNVD", "id": "CNNVD-202303-2507" }, { "db": "NVD", "id": "CVE-2022-43648" }, { "db": "NVD", "id": "CVE-2022-43648" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of D-Link DIR-3040 1.20B03 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the MiniDLNA service. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the MiniDLNA service. Was ZDI-CAN-19910. D-Link Systems, Inc. of DIR-3040 A heap-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. D-Link DIR-3040 is a router of D-Link company in China. Provides the ability to connect to the network", "sources": [ { "db": "NVD", "id": "CVE-2022-43648" }, { "db": "JVNDB", "id": "JVNDB-2022-022047" }, { "db": "ZDI", "id": "ZDI-23-052" }, { "db": "CNVD", "id": "CNVD-2023-27674" }, { "db": "VULMON", "id": "CVE-2022-43648" } ], "trust": 2.88 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-43648", "trust": 4.6 }, { "db": "ZDI", "id": "ZDI-23-052", "trust": 3.2 }, { "db": "DLINK", "id": "SAP10322", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2022-022047", "trust": 0.8 }, { "db": "ZDI_CAN", "id": "ZDI-CAN-19910", "trust": 0.7 }, { "db": "CNVD", "id": "CNVD-2023-27674", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202303-2507", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2022-43648", "trust": 0.1 } ], "sources": [ { "db": "ZDI", "id": "ZDI-23-052" }, { "db": "CNVD", "id": "CNVD-2023-27674" }, { "db": "VULMON", "id": "CVE-2022-43648" }, { "db": "JVNDB", "id": "JVNDB-2022-022047" }, { "db": "CNNVD", "id": "CNNVD-202303-2507" }, { "db": "NVD", "id": "CVE-2022-43648" } ] }, "id": "VAR-202301-1377", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-27674" } ], "trust": 0.84410257 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-27674" } ] }, "last_update_date": "2024-08-14T15:26:54.099000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "D-Link has issued an update to correct this vulnerability.", "trust": 0.7, "url": "https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10322" }, { "title": "Patch for D-Link DIR-3040 Buffer Overflow Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/418641" }, { "title": "D-Link DIR-3040 Security vulnerabilities", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=232544" } ], "sources": [ { "db": "ZDI", "id": "ZDI-23-052" }, { "db": "CNVD", "id": "CNVD-2023-27674" }, { "db": "CNNVD", "id": "CNNVD-202303-2507" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-122", "trust": 1.0 }, { "problemtype": "Heap-based buffer overflow (CWE-122) [ others ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-022047" }, { "db": "NVD", "id": "CVE-2022-43648" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.2, "url": "https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=sap10322" }, { "trust": 2.5, "url": "https://www.zerodayinitiative.com/advisories/zdi-23-052/" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-43648" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-43648/" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/122.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "ZDI", "id": "ZDI-23-052" }, { "db": "CNVD", "id": "CNVD-2023-27674" }, { "db": "VULMON", "id": "CVE-2022-43648" }, { "db": "JVNDB", "id": "JVNDB-2022-022047" }, { "db": "CNNVD", "id": "CNNVD-202303-2507" }, { "db": "NVD", "id": "CVE-2022-43648" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "ZDI", "id": "ZDI-23-052" }, { "db": "CNVD", "id": "CNVD-2023-27674" }, { "db": "VULMON", "id": "CVE-2022-43648" }, { "db": "JVNDB", "id": "JVNDB-2022-022047" }, { "db": "CNNVD", "id": "CNNVD-202303-2507" }, { "db": "NVD", "id": "CVE-2022-43648" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-01-18T00:00:00", "db": "ZDI", "id": "ZDI-23-052" }, { "date": "2023-04-14T00:00:00", "db": "CNVD", "id": "CNVD-2023-27674" }, { "date": "2023-03-29T00:00:00", "db": "VULMON", "id": "CVE-2022-43648" }, { "date": "2023-11-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-022047" }, { "date": "2023-03-29T00:00:00", "db": "CNNVD", "id": "CNNVD-202303-2507" }, { "date": "2023-03-29T19:15:21.390000", "db": "NVD", "id": "CVE-2022-43648" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-01-18T00:00:00", "db": "ZDI", "id": "ZDI-23-052" }, { "date": "2023-04-14T00:00:00", "db": "CNVD", "id": "CNVD-2023-27674" }, { "date": "2023-03-30T00:00:00", "db": "VULMON", "id": "CVE-2022-43648" }, { "date": "2023-11-15T03:14:00", "db": "JVNDB", "id": "JVNDB-2022-022047" }, { "date": "2023-04-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202303-2507" }, { "date": "2023-04-08T01:58:01.873000", "db": "NVD", "id": "CVE-2022-43648" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202303-2507" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "D-Link\u00a0Systems,\u00a0Inc.\u00a0 of \u00a0DIR-3040\u00a0 Heap-based buffer overflow vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-022047" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202303-2507" } ], "trust": 0.6 } }
var-202107-0568
Vulnerability from variot
A hard-coded password vulnerability exists in the Zebra IP Routing Manager functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to a denial of service. An attacker can send a sequence of requests to trigger this vulnerability. D-LINK DIR-3040 Is vulnerable to the use of hard-coded credentials.Denial of service (DoS) It may be put into a state. D-LINK DIR-3040 is a router of D-Link Corporation in Taiwan. Provides the function of connecting to the network. Attackers can cause the target to deny service through special requests. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202107-0568", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "dir-3040", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.13b03" }, { "model": "dir-3040", "scope": "eq", "trust": 0.8, "vendor": "d link", "version": null }, { "model": "dir-3040", "scope": "eq", "trust": 0.8, "vendor": "d link", "version": "dir-3040 firmware 1.13b03" }, { "model": "d-link dir-3040 1.13b03", "scope": null, "trust": 0.6, "vendor": "dlink", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-53335" }, { "db": "JVNDB", "id": "JVNDB-2021-009660" }, { "db": "NVD", "id": "CVE-2021-21818" } ] }, "cve": "CVE-2021-21818", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2021-21818", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2021-53335", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "talos-cna@cisco.com", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2021-21818", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.8, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2021-21818", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-21818", "trust": 1.0, "value": "HIGH" }, { "author": "talos-cna@cisco.com", "id": "CVE-2021-21818", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2021-21818", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-53335", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202107-1224", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-21818", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-53335" }, { "db": "VULMON", "id": "CVE-2021-21818" }, { "db": "JVNDB", "id": "JVNDB-2021-009660" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-1224" }, { "db": "NVD", "id": "CVE-2021-21818" }, { "db": "NVD", "id": "CVE-2021-21818" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A hard-coded password vulnerability exists in the Zebra IP Routing Manager functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to a denial of service. An attacker can send a sequence of requests to trigger this vulnerability. D-LINK DIR-3040 Is vulnerable to the use of hard-coded credentials.Denial of service (DoS) It may be put into a state. D-LINK DIR-3040 is a router of D-Link Corporation in Taiwan. Provides the function of connecting to the network. Attackers can cause the target to deny service through special requests. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements", "sources": [ { "db": "NVD", "id": "CVE-2021-21818" }, { "db": "JVNDB", "id": "JVNDB-2021-009660" }, { "db": "CNVD", "id": "CNVD-2021-53335" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "VULMON", "id": "CVE-2021-21818" } ], "trust": 2.79 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-21818", "trust": 3.9 }, { "db": "TALOS", "id": "TALOS-2021-1283", "trust": 3.1 }, { "db": "JVNDB", "id": "JVNDB-2021-009660", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-53335", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021041363", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021071610", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202107-1224", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-21818", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-53335" }, { "db": "VULMON", "id": "CVE-2021-21818" }, { "db": "JVNDB", "id": "JVNDB-2021-009660" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-1224" }, { "db": "NVD", "id": "CVE-2021-21818" } ] }, "id": "VAR-202107-0568", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-53335" } ], "trust": 1.222051285 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-53335" } ] }, "last_update_date": "2024-08-14T12:51:45.491000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top\u00a0Page", "trust": 0.8, "url": "https://www.dlink.com.br/" }, { "title": "Patch for D-LINK DIR-3040 trust management issue vulnerability (CNVD-2021-53335)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/280236" }, { "title": "D-Link D-LINK DIR-3040 Repair measures for trust management problem vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=156838" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-53335" }, { "db": "JVNDB", "id": "JVNDB-2021-009660" }, { "db": "CNNVD", "id": "CNNVD-202107-1224" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-798", "trust": 1.0 }, { "problemtype": "CWE-259", "trust": 1.0 }, { "problemtype": "Using hardcoded credentials (CWE-798) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-009660" }, { "db": "NVD", "id": "CVE-2021-21818" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.1, "url": "https://talosintelligence.com/vulnerability_reports/talos-2021-1283" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-21818" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021071610" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/798.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-53335" }, { "db": "VULMON", "id": "CVE-2021-21818" }, { "db": "JVNDB", "id": "JVNDB-2021-009660" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-1224" }, { "db": "NVD", "id": "CVE-2021-21818" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-53335" }, { "db": "VULMON", "id": "CVE-2021-21818" }, { "db": "JVNDB", "id": "JVNDB-2021-009660" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-1224" }, { "db": "NVD", "id": "CVE-2021-21818" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-07-22T00:00:00", "db": "CNVD", "id": "CNVD-2021-53335" }, { "date": "2021-07-16T00:00:00", "db": "VULMON", "id": "CVE-2021-21818" }, { "date": "2022-05-17T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-009660" }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-07-16T00:00:00", "db": "CNNVD", "id": "CNNVD-202107-1224" }, { "date": "2021-07-16T11:15:09.970000", "db": "NVD", "id": "CVE-2021-21818" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-07-22T00:00:00", "db": "CNVD", "id": "CNVD-2021-53335" }, { "date": "2021-07-22T00:00:00", "db": "VULMON", "id": "CVE-2021-21818" }, { "date": "2022-05-17T02:23:00", "db": "JVNDB", "id": "JVNDB-2021-009660" }, { "date": "2021-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-07-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202107-1224" }, { "date": "2022-07-29T14:49:00.107000", "db": "NVD", "id": "CVE-2021-21818" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202107-1224" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "D-LINK\u00a0DIR-3040\u00a0 Vulnerability in Using Hard Coded Credentials", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-009660" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-975" } ], "trust": 0.6 } }
var-202204-0705
Vulnerability from variot
A command injection vulnerability in the protest binary allows an attacker with access to the remote command line interface to execute arbitrary commands as root. dir-1360 firmware, dir-1760 firmware, dir-1960 For multiple D-Link Japan Co., Ltd. products such as firmware, OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202204-0705", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "dir-867", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.10b04" }, { "model": "dir-1960", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.03b03" }, { "model": "dir-1360", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.00b15" }, { "model": "dir-3040", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.11b02" }, { "model": "dir-2660", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.02b01" }, { "model": "dir-3060", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.02b03" }, { "model": "dir-882", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.30b06" }, { "model": "dir-882", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.30b10" }, { "model": "dir-2660", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.03b04" }, { "model": "dir-3040", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.20b03" }, { "model": "dir-2640", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.11b02" }, { "model": "dir-1360", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.03b02" }, { "model": "dir-3060", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.11b02" }, { "model": "dir-878", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.30b08" }, { "model": "dir-3040", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.13b03" }, { "model": "dir-1760", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.01b04" }, { "model": "dir-2660", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.00b14" }, { "model": "dir-867", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.30b07" }, { "model": "dir-1960", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.02b01" }, { "model": "dir-2660", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.01b03" }, { "model": "dir-3060", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.00b12" }, { "model": "dir-1360", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.01b03" }, { "model": "dir-1360", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.11b04" }, { "model": "dir-2660", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.11b04" }, { "model": "dir-1960", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.11b03" }, { "model": "dir-2660", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.04b03" }, { "model": "dir-2640", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.01b04" }, { "model": "dir-1760", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.11b03" }, { "model": "dir-3060", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.11b04" }, { "model": "dir-3040", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.12b01" }, { "model": "dir-882", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.20b06" }, { "model": "dir-1360", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.02b03" }, { "model": "dir-3060", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.01b07" }, { "model": "dir-867", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.20b10" }, { "model": "dir-878", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.20b05" }, { "model": "dir-882", "scope": null, "trust": 0.8, "vendor": "\u30c7\u30a3\u30fc\u30ea\u30f3\u30af\u30b8\u30e3\u30d1\u30f3\u682a\u5f0f\u4f1a\u793e", "version": null }, { "model": "dir-3040", "scope": null, "trust": 0.8, "vendor": "\u30c7\u30a3\u30fc\u30ea\u30f3\u30af\u30b8\u30e3\u30d1\u30f3\u682a\u5f0f\u4f1a\u793e", "version": null }, { "model": "dir-3060", "scope": null, "trust": 0.8, "vendor": "\u30c7\u30a3\u30fc\u30ea\u30f3\u30af\u30b8\u30e3\u30d1\u30f3\u682a\u5f0f\u4f1a\u793e", "version": null }, { "model": "dir-1760", "scope": null, "trust": 0.8, "vendor": "\u30c7\u30a3\u30fc\u30ea\u30f3\u30af\u30b8\u30e3\u30d1\u30f3\u682a\u5f0f\u4f1a\u793e", "version": null }, { "model": "dir-878", "scope": null, "trust": 0.8, "vendor": "\u30c7\u30a3\u30fc\u30ea\u30f3\u30af\u30b8\u30e3\u30d1\u30f3\u682a\u5f0f\u4f1a\u793e", "version": null }, { "model": "dir-2660", "scope": null, "trust": 0.8, "vendor": "\u30c7\u30a3\u30fc\u30ea\u30f3\u30af\u30b8\u30e3\u30d1\u30f3\u682a\u5f0f\u4f1a\u793e", "version": null }, { "model": "dir-1360", "scope": null, "trust": 0.8, "vendor": "\u30c7\u30a3\u30fc\u30ea\u30f3\u30af\u30b8\u30e3\u30d1\u30f3\u682a\u5f0f\u4f1a\u793e", "version": null }, { "model": "dir-1960", "scope": null, "trust": 0.8, "vendor": "\u30c7\u30a3\u30fc\u30ea\u30f3\u30af\u30b8\u30e3\u30d1\u30f3\u682a\u5f0f\u4f1a\u793e", "version": null }, { "model": "dir-867", "scope": null, "trust": 0.8, "vendor": "\u30c7\u30a3\u30fc\u30ea\u30f3\u30af\u30b8\u30e3\u30d1\u30f3\u682a\u5f0f\u4f1a\u793e", "version": null }, { "model": "dir-2640", "scope": null, "trust": 0.8, "vendor": "\u30c7\u30a3\u30fc\u30ea\u30f3\u30af\u30b8\u30e3\u30d1\u30f3\u682a\u5f0f\u4f1a\u793e", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-008159" }, { "db": "NVD", "id": "CVE-2022-1262" } ] }, "cve": "CVE-2022-1262", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 3.9, "id": "CVE-2022-1262", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 1.9, "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "id": "CVE-2022-1262", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2022-1262", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2022-1262", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2022-1262", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-202204-2826", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2022-1262", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2022-1262" }, { "db": "JVNDB", "id": "JVNDB-2022-008159" }, { "db": "CNNVD", "id": "CNNVD-202204-2826" }, { "db": "NVD", "id": "CVE-2022-1262" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A command injection vulnerability in the protest binary allows an attacker with access to the remote command line interface to execute arbitrary commands as root. dir-1360 firmware, dir-1760 firmware, dir-1960 For multiple D-Link Japan Co., Ltd. products such as firmware, OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2022-1262" }, { "db": "JVNDB", "id": "JVNDB-2022-008159" }, { "db": "VULMON", "id": "CVE-2022-1262" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-1262", "trust": 3.3 }, { "db": "TENABLE", "id": "TRA-2022-09", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2022-008159", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202204-2826", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2022-1262", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2022-1262" }, { "db": "JVNDB", "id": "JVNDB-2022-008159" }, { "db": "CNNVD", "id": "CNNVD-202204-2826" }, { "db": "NVD", "id": "CVE-2022-1262" } ] }, "id": "VAR-202204-0705", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.4205193725 }, "last_update_date": "2024-11-23T22:32:53.734000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "D-Link Routers Fixes for operating system command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=189807" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202204-2826" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-78", "trust": 1.0 }, { "problemtype": "OS Command injection (CWE-78) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-008159" }, { "db": "NVD", "id": "CVE-2022-1262" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://www.tenable.com/security/research/tra-2022-09" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-1262" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-1262/" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/78.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2022-1262" }, { "db": "JVNDB", "id": "JVNDB-2022-008159" }, { "db": "CNNVD", "id": "CNNVD-202204-2826" }, { "db": "NVD", "id": "CVE-2022-1262" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2022-1262" }, { "db": "JVNDB", "id": "JVNDB-2022-008159" }, { "db": "CNNVD", "id": "CNNVD-202204-2826" }, { "db": "NVD", "id": "CVE-2022-1262" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-04-11T00:00:00", "db": "VULMON", "id": "CVE-2022-1262" }, { "date": "2023-07-24T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-008159" }, { "date": "2022-04-11T00:00:00", "db": "CNNVD", "id": "CNNVD-202204-2826" }, { "date": "2022-04-11T20:15:18.157000", "db": "NVD", "id": "CVE-2022-1262" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-04-18T00:00:00", "db": "VULMON", "id": "CVE-2022-1262" }, { "date": "2023-07-24T08:23:00", "db": "JVNDB", "id": "JVNDB-2022-008159" }, { "date": "2022-04-19T00:00:00", "db": "CNNVD", "id": "CNNVD-202204-2826" }, { "date": "2024-11-21T06:40:21.910000", "db": "NVD", "id": "CVE-2022-1262" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202204-2826" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "In multiple D-Link Japan Co., Ltd. products \u00a0OS\u00a0 Command injection vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-008159" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "operating system commend injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202204-2826" } ], "trust": 0.6 } }
var-202107-0567
Vulnerability from variot
An information disclosure vulnerability exists in the Zebra IP Routing Manager functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to the disclosure of sensitive information. An attacker can send a sequence of requests to trigger this vulnerability. D-LINK DIR-3040 Contains an unspecified vulnerability.Information may be obtained. D-LINK DIR-3040 is a router of D-Link company in Taiwan, China, which provides the function of connecting to the network. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202107-0567", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "dir-3040", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.13b03" }, { "model": "dir-3040", "scope": "eq", "trust": 0.8, "vendor": "d link", "version": null }, { "model": "dir-3040", "scope": "eq", "trust": 0.8, "vendor": "d link", "version": "dir-3040 firmware 1.13b03" }, { "model": "dir-3040", "scope": null, "trust": 0.6, "vendor": "d link", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-53341" }, { "db": "JVNDB", "id": "JVNDB-2021-009659" }, { "db": "NVD", "id": "CVE-2021-21817" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Discovered by Dave McDaniel of Cisco Talos.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202107-1118" } ], "trust": 0.6 }, "cve": "CVE-2021-21817", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2021-21817", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 7.8, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2021-53341", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "talos-cna@cisco.com", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2021-21817", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.8, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" }, { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2021-21817", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-21817", "trust": 1.0, "value": "HIGH" }, { "author": "talos-cna@cisco.com", "id": "CVE-2021-21817", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2021-21817", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-53341", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202107-1118", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-21817", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-53341" }, { "db": "VULMON", "id": "CVE-2021-21817" }, { "db": "JVNDB", "id": "JVNDB-2021-009659" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-1118" }, { "db": "NVD", "id": "CVE-2021-21817" }, { "db": "NVD", "id": "CVE-2021-21817" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "An information disclosure vulnerability exists in the Zebra IP Routing Manager functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to the disclosure of sensitive information. An attacker can send a sequence of requests to trigger this vulnerability. D-LINK DIR-3040 Contains an unspecified vulnerability.Information may be obtained. D-LINK DIR-3040 is a router of D-Link company in Taiwan, China, which provides the function of connecting to the network. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements", "sources": [ { "db": "NVD", "id": "CVE-2021-21817" }, { "db": "JVNDB", "id": "JVNDB-2021-009659" }, { "db": "CNVD", "id": "CNVD-2021-53341" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "VULMON", "id": "CVE-2021-21817" } ], "trust": 2.79 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-21817", "trust": 3.9 }, { "db": "TALOS", "id": "TALOS-2021-1282", "trust": 3.1 }, { "db": "JVNDB", "id": "JVNDB-2021-009659", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-53341", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021041363", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021071610", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202107-1118", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-21817", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-53341" }, { "db": "VULMON", "id": "CVE-2021-21817" }, { "db": "JVNDB", "id": "JVNDB-2021-009659" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-1118" }, { "db": "NVD", "id": "CVE-2021-21817" } ] }, "id": "VAR-202107-0567", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-53341" } ], "trust": 0.84410257 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-53341" } ] }, "last_update_date": "2024-08-14T13:08:05.926000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top\u00a0Page", "trust": 0.8, "url": "https://www.dlink.com.br/" }, { "title": "Patch for D-LINK DIR-3040 Information Disclosure Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/280321" }, { "title": "D-LINK DIR-3040 Repair measures for information disclosure vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=156799" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-53341" }, { "db": "JVNDB", "id": "JVNDB-2021-009659" }, { "db": "CNNVD", "id": "CNNVD-202107-1118" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-200", "trust": 1.0 }, { "problemtype": "Lack of information (CWE-noinfo) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-009659" }, { "db": "NVD", "id": "CVE-2021-21817" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.7, "url": "https://talosintelligence.com/vulnerability_reports/talos-2021-1282" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-21817" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021071610" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-53341" }, { "db": "VULMON", "id": "CVE-2021-21817" }, { "db": "JVNDB", "id": "JVNDB-2021-009659" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-1118" }, { "db": "NVD", "id": "CVE-2021-21817" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-53341" }, { "db": "VULMON", "id": "CVE-2021-21817" }, { "db": "JVNDB", "id": "JVNDB-2021-009659" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-1118" }, { "db": "NVD", "id": "CVE-2021-21817" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-07-22T00:00:00", "db": "CNVD", "id": "CNVD-2021-53341" }, { "date": "2021-07-16T00:00:00", "db": "VULMON", "id": "CVE-2021-21817" }, { "date": "2022-05-17T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-009659" }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-07-15T00:00:00", "db": "CNNVD", "id": "CNNVD-202107-1118" }, { "date": "2021-07-16T11:15:09.937000", "db": "NVD", "id": "CVE-2021-21817" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-07-22T00:00:00", "db": "CNVD", "id": "CNVD-2021-53341" }, { "date": "2021-07-22T00:00:00", "db": "VULMON", "id": "CVE-2021-21817" }, { "date": "2022-05-17T02:23:00", "db": "JVNDB", "id": "JVNDB-2021-009659" }, { "date": "2021-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2022-08-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202107-1118" }, { "date": "2022-07-29T12:54:27.817000", "db": "NVD", "id": "CVE-2021-21817" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202107-1118" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "D-LINK DIR-3040 Information Disclosure Vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2021-53341" }, { "db": "CNNVD", "id": "CNNVD-202107-1118" } ], "trust": 1.2 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-975" } ], "trust": 0.6 } }
var-202107-0566
Vulnerability from variot
An information disclosure vulnerability exists in the Syslog functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to the disclosure of sensitive information. An attacker can send an HTTP request to trigger this vulnerability. D-LINK DIR-3040 There is a vulnerability in the insecure storage of important information.Information may be obtained. D-LINK DIR-3040 is a router of D-Link company in Taiwan, China, which provides the function of connecting to the network. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202107-0566", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "dir-3040", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.13b03" }, { "model": "dir-3040", "scope": "eq", "trust": 0.8, "vendor": "d link", "version": null }, { "model": "dir-3040", "scope": "eq", "trust": 0.8, "vendor": "d link", "version": "dir-3040 firmware 1.13b03" }, { "model": "dir-3040", "scope": null, "trust": 0.6, "vendor": "d link", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-53338" }, { "db": "JVNDB", "id": "JVNDB-2021-010095" }, { "db": "NVD", "id": "CVE-2021-21816" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Discovered by Dave McDaniel of Cisco Talos.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202107-1085" } ], "trust": 0.6 }, "cve": "CVE-2021-21816", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "CVE-2021-21816", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.9, "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 7.8, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2021-53338", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 4.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 2.8, "id": "CVE-2021-21816", "impactScore": 1.4, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "talos-cna@cisco.com", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2021-21816", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 4.3, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "CVE-2021-21816", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-21816", "trust": 1.0, "value": "MEDIUM" }, { "author": "talos-cna@cisco.com", "id": "CVE-2021-21816", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "CVE-2021-21816", "trust": 0.8, "value": "Medium" }, { "author": "CNVD", "id": "CNVD-2021-53338", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202107-1085", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-21816", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-53338" }, { "db": "VULMON", "id": "CVE-2021-21816" }, { "db": "JVNDB", "id": "JVNDB-2021-010095" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-1085" }, { "db": "NVD", "id": "CVE-2021-21816" }, { "db": "NVD", "id": "CVE-2021-21816" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "An information disclosure vulnerability exists in the Syslog functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to the disclosure of sensitive information. An attacker can send an HTTP request to trigger this vulnerability. D-LINK DIR-3040 There is a vulnerability in the insecure storage of important information.Information may be obtained. D-LINK DIR-3040 is a router of D-Link company in Taiwan, China, which provides the function of connecting to the network. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements", "sources": [ { "db": "NVD", "id": "CVE-2021-21816" }, { "db": "JVNDB", "id": "JVNDB-2021-010095" }, { "db": "CNVD", "id": "CNVD-2021-53338" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "VULMON", "id": "CVE-2021-21816" } ], "trust": 2.79 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-21816", "trust": 3.9 }, { "db": "TALOS", "id": "TALOS-2021-1281", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2021-010095", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-53338", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021041363", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021071610", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202107-1085", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-21816", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-53338" }, { "db": "VULMON", "id": "CVE-2021-21816" }, { "db": "JVNDB", "id": "JVNDB-2021-010095" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-1085" }, { "db": "NVD", "id": "CVE-2021-21816" } ] }, "id": "VAR-202107-0566", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-53338" } ], "trust": 0.84410257 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-53338" } ] }, "last_update_date": "2024-08-14T12:52:51.039000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top\u00a0Page", "trust": 0.8, "url": "https://www.dlink.com.br/" }, { "title": "Kenzer Templates [5170] [DEPRECATED]", "trust": 0.1, "url": "https://github.com/ARPSyndicate/kenzer-templates " } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-21816" }, { "db": "JVNDB", "id": "JVNDB-2021-010095" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-200", "trust": 1.0 }, { "problemtype": "Insecure storage of important information (CWE-922) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-010095" }, { "db": "NVD", "id": "CVE-2021-21816" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.1, "url": "https://talosintelligence.com/vulnerability_reports/talos-2021-1281" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-21816" }, { "trust": 0.6, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-21816" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021071610" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/200.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://github.com/arpsyndicate/kenzer-templates" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-53338" }, { "db": "VULMON", "id": "CVE-2021-21816" }, { "db": "JVNDB", "id": "JVNDB-2021-010095" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-1085" }, { "db": "NVD", "id": "CVE-2021-21816" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-53338" }, { "db": "VULMON", "id": "CVE-2021-21816" }, { "db": "JVNDB", "id": "JVNDB-2021-010095" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-1085" }, { "db": "NVD", "id": "CVE-2021-21816" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-07-22T00:00:00", "db": "CNVD", "id": "CNVD-2021-53338" }, { "date": "2021-07-16T00:00:00", "db": "VULMON", "id": "CVE-2021-21816" }, { "date": "2022-06-17T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-010095" }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-07-15T00:00:00", "db": "CNNVD", "id": "CNNVD-202107-1085" }, { "date": "2021-07-16T11:15:09.900000", "db": "NVD", "id": "CVE-2021-21816" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-07-22T00:00:00", "db": "CNVD", "id": "CNVD-2021-53338" }, { "date": "2023-04-26T00:00:00", "db": "VULMON", "id": "CVE-2021-21816" }, { "date": "2022-06-17T05:52:00", "db": "JVNDB", "id": "JVNDB-2021-010095" }, { "date": "2021-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2022-08-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202107-1085" }, { "date": "2023-04-26T19:27:52.350000", "db": "NVD", "id": "CVE-2021-21816" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202107-1085" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "D-LINK\u00a0DIR-3040\u00a0 Vulnerability in insecure storage of critical information in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-010095" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-975" } ], "trust": 0.6 } }
var-202107-0570
Vulnerability from variot
A hard-coded password vulnerability exists in the Libcli Test Environment functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to code execution. An attacker can send a sequence of requests to trigger this vulnerability. D-LINK DIR-3040 Is vulnerable to the use of hard-coded credentials.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. D-Link DIR-3040 is a router of D-Link company in Taiwan. Provides the function of connecting to the network. No detailed vulnerability details are currently provided. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202107-0570", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "dir-3040", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.13b03" }, { "model": "dir-3040", "scope": "eq", "trust": 0.8, "vendor": "d link", "version": null }, { "model": "dir-3040", "scope": "eq", "trust": 0.8, "vendor": "d link", "version": "dir-3040 firmware 1.13b03" }, { "model": "d-link dir-3040 1.13b03", "scope": null, "trust": 0.6, "vendor": "dlink", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-52960" }, { "db": "JVNDB", "id": "JVNDB-2021-009662" }, { "db": "NVD", "id": "CVE-2021-21820" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Discovered by Dave McDaniel of Cisco Talos.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202107-1124" } ], "trust": 0.6 }, "cve": "CVE-2021-21820", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2021-21820", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2021-52960", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2021-21820", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "talos-cna@cisco.com", "availabilityImpact": "HIGH", "baseScore": 10.0, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2021-21820", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-21820", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-21820", "trust": 1.0, "value": "CRITICAL" }, { "author": "talos-cna@cisco.com", "id": "CVE-2021-21820", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2021-21820", "trust": 0.8, "value": "Critical" }, { "author": "CNVD", "id": "CNVD-2021-52960", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202107-1124", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-21820", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-52960" }, { "db": "VULMON", "id": "CVE-2021-21820" }, { "db": "JVNDB", "id": "JVNDB-2021-009662" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-1124" }, { "db": "NVD", "id": "CVE-2021-21820" }, { "db": "NVD", "id": "CVE-2021-21820" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A hard-coded password vulnerability exists in the Libcli Test Environment functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to code execution. An attacker can send a sequence of requests to trigger this vulnerability. D-LINK DIR-3040 Is vulnerable to the use of hard-coded credentials.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. D-Link DIR-3040 is a router of D-Link company in Taiwan. Provides the function of connecting to the network. No detailed vulnerability details are currently provided. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements", "sources": [ { "db": "NVD", "id": "CVE-2021-21820" }, { "db": "JVNDB", "id": "JVNDB-2021-009662" }, { "db": "CNVD", "id": "CNVD-2021-52960" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "VULMON", "id": "CVE-2021-21820" } ], "trust": 2.79 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-21820", "trust": 3.9 }, { "db": "TALOS", "id": "TALOS-2021-1285", "trust": 3.1 }, { "db": "JVNDB", "id": "JVNDB-2021-009662", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-52960", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021041363", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021071610", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202107-1124", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-21820", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-52960" }, { "db": "VULMON", "id": "CVE-2021-21820" }, { "db": "JVNDB", "id": "JVNDB-2021-009662" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-1124" }, { "db": "NVD", "id": "CVE-2021-21820" } ] }, "id": "VAR-202107-0570", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-52960" } ], "trust": 1.222051285 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-52960" } ] }, "last_update_date": "2024-08-14T12:51:08.125000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top\u00a0Page", "trust": 0.8, "url": "https://www.dlink.com.br/" }, { "title": "Patch for D-LINK DIR-3040 Trust Management Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/280116" }, { "title": "D-LINK DIR-3040 Repair measures for trust management problem vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=156803" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-52960" }, { "db": "JVNDB", "id": "JVNDB-2021-009662" }, { "db": "CNNVD", "id": "CNNVD-202107-1124" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-798", "trust": 1.0 }, { "problemtype": "Using hardcoded credentials (CWE-798) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-009662" }, { "db": "NVD", "id": "CVE-2021-21820" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.7, "url": "https://talosintelligence.com/vulnerability_reports/talos-2021-1285" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-21820" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021071610" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/798.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-52960" }, { "db": "VULMON", "id": "CVE-2021-21820" }, { "db": "JVNDB", "id": "JVNDB-2021-009662" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-1124" }, { "db": "NVD", "id": "CVE-2021-21820" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-52960" }, { "db": "VULMON", "id": "CVE-2021-21820" }, { "db": "JVNDB", "id": "JVNDB-2021-009662" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-1124" }, { "db": "NVD", "id": "CVE-2021-21820" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-07-21T00:00:00", "db": "CNVD", "id": "CNVD-2021-52960" }, { "date": "2021-07-16T00:00:00", "db": "VULMON", "id": "CVE-2021-21820" }, { "date": "2022-05-17T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-009662" }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-07-15T00:00:00", "db": "CNNVD", "id": "CNNVD-202107-1124" }, { "date": "2021-07-16T11:15:10.037000", "db": "NVD", "id": "CVE-2021-21820" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-07-21T00:00:00", "db": "CNVD", "id": "CNVD-2021-52960" }, { "date": "2021-07-22T00:00:00", "db": "VULMON", "id": "CVE-2021-21820" }, { "date": "2022-05-17T02:23:00", "db": "JVNDB", "id": "JVNDB-2021-009662" }, { "date": "2021-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2022-08-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202107-1124" }, { "date": "2022-07-29T14:54:26.580000", "db": "NVD", "id": "CVE-2021-21820" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202107-1124" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "D-LINK\u00a0DIR-3040\u00a0 Vulnerability in Using Hard Coded Credentials", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-009662" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-975" } ], "trust": 0.6 } }
var-202109-0383
Vulnerability from variot
An information disclosure vulnerability exists in the WiFi Smart Mesh functionality of D-LINK DIR-3040 1.13B03. A specially-crafted network request can lead to command execution. An attacker can connect to the MQTT service to trigger this vulnerability. D-LINK DIR-3040 Contains a vulnerability in the use of hard-coded credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. D-LINK DIR-3040 is a router of D-Link Corporation in Taiwan. Provides the function of connecting to the network
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202109-0383", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "dir-3040", "scope": "eq", "trust": 1.0, "vendor": "dlink", "version": "1.13b03" }, { "model": "dir-3040", "scope": "eq", "trust": 0.8, "vendor": "d link", "version": "dir-3040 firmware 1.13b03" }, { "model": "dir-3040", "scope": "eq", "trust": 0.8, "vendor": "d link", "version": null }, { "model": "dir-3040 1.13b03", "scope": null, "trust": 0.6, "vendor": "d link", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-94832" }, { "db": "JVNDB", "id": "JVNDB-2021-012254" }, { "db": "NVD", "id": "CVE-2021-21913" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Discovered by Dave McDaniel of Cisco Talos.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202109-1637" } ], "trust": 0.6 }, "cve": "CVE-2021-21913", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2021-21913", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CNVD-2021-94832", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2021-21913", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "talos-cna@cisco.com", "availabilityImpact": "HIGH", "baseScore": 10.0, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2021-21913", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-21913", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-21913", "trust": 1.0, "value": "CRITICAL" }, { "author": "talos-cna@cisco.com", "id": "CVE-2021-21913", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2021-21913", "trust": 0.8, "value": "Critical" }, { "author": "CNVD", "id": "CNVD-2021-94832", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202109-1637", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-21913", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-94832" }, { "db": "VULMON", "id": "CVE-2021-21913" }, { "db": "JVNDB", "id": "JVNDB-2021-012254" }, { "db": "CNNVD", "id": "CNNVD-202109-1637" }, { "db": "NVD", "id": "CVE-2021-21913" }, { "db": "NVD", "id": "CVE-2021-21913" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "An information disclosure vulnerability exists in the WiFi Smart Mesh functionality of D-LINK DIR-3040 1.13B03. A specially-crafted network request can lead to command execution. An attacker can connect to the MQTT service to trigger this vulnerability. D-LINK DIR-3040 Contains a vulnerability in the use of hard-coded credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. D-LINK DIR-3040 is a router of D-Link Corporation in Taiwan. Provides the function of connecting to the network", "sources": [ { "db": "NVD", "id": "CVE-2021-21913" }, { "db": "JVNDB", "id": "JVNDB-2021-012254" }, { "db": "CNVD", "id": "CNVD-2021-94832" }, { "db": "VULMON", "id": "CVE-2021-21913" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-21913", "trust": 3.9 }, { "db": "TALOS", "id": "TALOS-2021-1361", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2021-012254", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-94832", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202109-1637", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-21913", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-94832" }, { "db": "VULMON", "id": "CVE-2021-21913" }, { "db": "JVNDB", "id": "JVNDB-2021-012254" }, { "db": "CNNVD", "id": "CNNVD-202109-1637" }, { "db": "NVD", "id": "CVE-2021-21913" } ] }, "id": "VAR-202109-0383", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-94832" } ], "trust": 0.84410257 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-94832" } ] }, "last_update_date": "2024-08-14T15:42:45.375000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top\u00a0Page", "trust": 0.8, "url": "https://www.dlink.com.br/" }, { "title": "Patch for D-LINK DIR-3040 Information Disclosure Vulnerability (CNVD-2021-94832)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/302886" }, { "title": "D-LINK DIR-3040 Repair measures for trust management problem vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=164248" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-94832" }, { "db": "JVNDB", "id": "JVNDB-2021-012254" }, { "db": "CNNVD", "id": "CNNVD-202109-1637" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-798", "trust": 1.0 }, { "problemtype": "Use hard-coded credentials (CWE-798) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-012254" }, { "db": "NVD", "id": "CVE-2021-21913" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.1, "url": "https://talosintelligence.com/vulnerability_reports/talos-2021-1361" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-21913" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/798.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-94832" }, { "db": "VULMON", "id": "CVE-2021-21913" }, { "db": "JVNDB", "id": "JVNDB-2021-012254" }, { "db": "CNNVD", "id": "CNNVD-202109-1637" }, { "db": "NVD", "id": "CVE-2021-21913" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-94832" }, { "db": "VULMON", "id": "CVE-2021-21913" }, { "db": "JVNDB", "id": "JVNDB-2021-012254" }, { "db": "CNNVD", "id": "CNNVD-202109-1637" }, { "db": "NVD", "id": "CVE-2021-21913" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-07T00:00:00", "db": "CNVD", "id": "CNVD-2021-94832" }, { "date": "2021-09-23T00:00:00", "db": "VULMON", "id": "CVE-2021-21913" }, { "date": "2022-08-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-012254" }, { "date": "2021-09-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202109-1637" }, { "date": "2021-09-23T15:15:07.527000", "db": "NVD", "id": "CVE-2021-21913" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-07T00:00:00", "db": "CNVD", "id": "CNVD-2021-94832" }, { "date": "2021-09-29T00:00:00", "db": "VULMON", "id": "CVE-2021-21913" }, { "date": "2022-08-26T07:25:00", "db": "JVNDB", "id": "JVNDB-2021-012254" }, { "date": "2021-09-30T00:00:00", "db": "CNNVD", "id": "CNNVD-202109-1637" }, { "date": "2022-07-21T11:45:38.103000", "db": "NVD", "id": "CVE-2021-21913" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202109-1637" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "D-LINK\u00a0DIR-3040\u00a0 Vulnerability in using hard-coded credentials in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-012254" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "trust management problem", "sources": [ { "db": "CNNVD", "id": "CNNVD-202109-1637" } ], "trust": 0.6 } }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
zdi-disclosures@trendmicro.com | https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10322 | Patch, Vendor Advisory | |
zdi-disclosures@trendmicro.com | https://www.zerodayinitiative.com/advisories/ZDI-23-052/ | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10322 | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.zerodayinitiative.com/advisories/ZDI-23-052/ | Third Party Advisory, VDB Entry |
Vendor | Product | Version | |
---|---|---|---|
dlink | dir-3040_firmware | * | |
dlink | dir-3040 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-3040_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE85C913-4C4E-44C3-9E06-0A822FA8E001", "versionEndIncluding": "1.20b03", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-3040:-:*:*:*:*:*:*:*", "matchCriteriaId": "A4EDA686-7BB6-49CB-8370-E0E5F53914A8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of D-Link DIR-3040 1.20B03 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the MiniDLNA service. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the MiniDLNA service. Was ZDI-CAN-19910." } ], "id": "CVE-2022-43648", "lastModified": "2024-11-21T07:26:58.283", "metrics": { "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "zdi-disclosures@trendmicro.com", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-03-29T19:15:21.390", "references": [ { "source": "zdi-disclosures@trendmicro.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10322" }, { "source": "zdi-disclosures@trendmicro.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-052/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10322" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-052/" } ], "sourceIdentifier": "zdi-disclosures@trendmicro.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-122" } ], "source": "zdi-disclosures@trendmicro.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
talos-cna@cisco.com | https://talosintelligence.com/vulnerability_reports/TALOS-2021-1283 | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://talosintelligence.com/vulnerability_reports/TALOS-2021-1283 | Exploit, Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
dlink | dir-3040_firmware | 1.13b03 | |
dlink | dir-3040 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-3040_firmware:1.13b03:*:*:*:*:*:*:*", "matchCriteriaId": "8495556A-FE73-4D22-A3F1-367D0D143DBD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-3040:-:*:*:*:*:*:*:*", "matchCriteriaId": "A4EDA686-7BB6-49CB-8370-E0E5F53914A8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A hard-coded password vulnerability exists in the Zebra IP Routing Manager functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to a denial of service. An attacker can send a sequence of requests to trigger this vulnerability." }, { "lang": "es", "value": "Se presenta una vulnerabilidad de contrase\u00f1a embebida en la funcionalidad Zebra IP Routing Manager de D-LINK DIR-3040 versi\u00f3n 1.13B03. Una petici\u00f3n de red especialmente dise\u00f1ada puede conllevar a una denegaci\u00f3n de servicio. Un atacante puede enviar una secuencia de peticiones para activar esta vulnerabilidad" } ], "id": "CVE-2021-21818", "lastModified": "2024-11-21T05:49:02.200", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "talos-cna@cisco.com", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-07-16T11:15:09.970", "references": [ { "source": "talos-cna@cisco.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1283" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1283" } ], "sourceIdentifier": "talos-cna@cisco.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-259" } ], "source": "talos-cna@cisco.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-798" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
vulnreport@tenable.com | https://www.tenable.com/security/research/tra-2022-09 | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.tenable.com/security/research/tra-2022-09 | Exploit, Third Party Advisory |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-1360_firmware:1.02b03:*:*:*:*:*:*:*", "matchCriteriaId": "CF007E45-F1D5-4B86-8C32-4522BB78B113", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-1360_firmware:1.03b02:*:*:*:*:*:*:*", "matchCriteriaId": "9EE0B84B-984C-405B-AD53-89F048F48721", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-1360_firmware:1.11b04:*:*:*:*:*:*:*", "matchCriteriaId": "E091E879-E4C2-4782-9E47-C712A7947727", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-1360:a1:*:*:*:*:*:*:*", "matchCriteriaId": "C8E7C9EC-241F-4698-9878-DC02CB1B69E2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-1760_firmware:1.01b04:*:*:*:*:*:*:*", "matchCriteriaId": "CA7235AB-E767-4772-99F4-2CC3046564EC", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-1760_firmware:1.11b03:beta:*:*:*:*:*:*", "matchCriteriaId": "D6FEFE51-389C-478A-B2D5-AAF2066649C4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-1760:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C961D12-61B7-440A-B7CE-C431E6903CDC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-1960_firmware:1.02b01:*:*:*:*:*:*:*", "matchCriteriaId": "94032F8E-AB47-451C-B5C2-21724ABB43DE", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-1960_firmware:1.03b03:*:*:*:*:*:*:*", "matchCriteriaId": "4292CE32-F5C9-4714-AE2E-577C304EA441", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-1960_firmware:1.11b03:*:*:*:*:*:*:*", "matchCriteriaId": "490294F3-F68E-43A4-8570-A4BDF233BEED", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-1960:a1:*:*:*:*:*:*:*", "matchCriteriaId": "144284ED-C086-49DE-8516-844A6CD2A30C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-2640_firmware:1.11b02:beta:*:*:*:*:*:*", "matchCriteriaId": "9141FC19-E6B2-4BA3-9166-A173BF772A6E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-2640:-:*:*:*:*:*:*:*", "matchCriteriaId": "D68A4D09-6C9A-4F3B-863D-DF612DB8DB89", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-2660_firmware:1.04b03:*:*:*:*:*:*:*", "matchCriteriaId": "03EB40C9-7AA1-4850-8856-A10D0A4759D2", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-2660_firmware:1.11b04:*:*:*:*:*:*:*", "matchCriteriaId": "F695ADF7-0327-4983-A4E2-174C15674B37", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-2660:a1:*:*:*:*:*:*:*", "matchCriteriaId": "D043D251-10DA-4939-BEBA-284A4A956B0D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-3040_firmware:1.13b03:beta:*:*:*:*:*:*", "matchCriteriaId": "22A3B1DF-2D8E-4709-A7FA-8EAD016DA9F6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-3040:-:*:*:*:*:*:*:*", "matchCriteriaId": "A4EDA686-7BB6-49CB-8370-E0E5F53914A8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-3060_firmware:1.00b12:*:*:*:*:*:*:*", "matchCriteriaId": "335C34AB-4223-4D81-B664-C0E730B0BFBA", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-3060_firmware:1.11b04:beta:*:*:*:*:*:*", "matchCriteriaId": "BE1DF67D-9464-4FEA-A5F6-BD5AC47D4E2F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-3060:-:*:*:*:*:*:*:*", "matchCriteriaId": "1B48DF58-000E-4846-BEB6-69E4E69375E7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-867_firmware:1.20b10:*:*:*:*:*:*:*", "matchCriteriaId": "12D2E414-7BC6-432D-897B-35FFAE944374", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-867:a1:*:*:*:*:*:*:*", "matchCriteriaId": "9747CBE7-1ECC-403F-93FC-0BBBE0124111", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-878_firmware:1.20b05:*:*:*:*:*:*:*", "matchCriteriaId": "D1CD2BE2-2157-4ADA-986F-2033EF15BC56", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-878_firmware:1.30b08:*:*:*:*:*:*:*", "matchCriteriaId": "7BFB6A28-3330-449A-A738-C2AC52B04C6B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-878:-:*:*:*:*:*:*:*", "matchCriteriaId": "9D288C73-F89A-47FF-AF11-143C3DFDF942", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-882_firmware:1.20b06:*:*:*:*:*:*:*", "matchCriteriaId": "DEBD8322-35F5-40FC-B8F7-1C74AD9C6259", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-882:-:*:*:*:*:*:*:*", "matchCriteriaId": "F6ECB8ED-F3A2-4C05-8570-719ECB166B09", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-1360_firmware:1.00b15:*:*:*:*:*:*:*", "matchCriteriaId": "CD10B74D-AE8C-40EC-99E5-2298A3085840", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-1360_firmware:1.01b03:*:*:*:*:*:*:*", "matchCriteriaId": "7C7BF035-A533-4F38-9E4F-04A83D648B20", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-1360_firmware:1.11b04:beta:*:*:*:*:*:*", "matchCriteriaId": "37851FB0-40E6-4BA7-9A9C-E127851E4032", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-1360:-:*:*:*:*:*:*:*", "matchCriteriaId": "CD91DDBE-83E8-4F3A-BB71-1EC8798DD086", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-1960_firmware:1.11b03:beta:*:*:*:*:*:*", "matchCriteriaId": "97E30469-D830-457F-B1FD-7BA3DA8B49E3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-1960:-:*:*:*:*:*:*:*", "matchCriteriaId": "67D40051-D7D8-4C76-B006-A94D501647C6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-2640_firmware:1.01b04:*:*:*:*:*:*:*", "matchCriteriaId": "114D694E-3858-4FCA-BE67-65C78256C0FF", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-2640_firmware:1.11b02:*:*:*:*:*:*:*", "matchCriteriaId": "AC690F1B-7B27-42A1-853A-EF04959FCF07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-2640:a1:*:*:*:*:*:*:*", "matchCriteriaId": "F950267C-AA12-4B1B-9995-66CDB0512757", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-2660_firmware:1.00b14:*:*:*:*:*:*:*", "matchCriteriaId": "50F1ACBB-BE31-4912-862D-05866A0AD7C5", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-2660_firmware:1.01b03:*:*:*:*:*:*:*", "matchCriteriaId": "900238FF-5D28-4EF3-B8D2-92D9525EAF62", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-2660_firmware:1.02b01:*:*:*:*:*:*:*", "matchCriteriaId": "2BAB44B3-A735-4BAA-89E4-11EAB2E62EBF", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-2660_firmware:1.03b04:*:*:*:*:*:*:*", "matchCriteriaId": "2C4EF06F-6619-4523-977A-0A3780D65C08", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-2660_firmware:1.11b04:beta:*:*:*:*:*:*", "matchCriteriaId": "4B621EA3-5396-4E84-A2FA-0DB68CEE4583", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-2660:-:*:*:*:*:*:*:*", "matchCriteriaId": "37C4E9FB-B4B0-40A8-A0B0-398050F9180D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-3040_firmware:1.11b02:*:*:*:*:*:*:*", "matchCriteriaId": "536F60AF-6A0B-419A-B2EC-E13D6D7FC398", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-3040_firmware:1.12b01:*:*:*:*:*:*:*", "matchCriteriaId": "F5681FB5-5F16-439F-B40E-A5FBBF15DEE5", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-3040_firmware:1.13b03:*:*:*:*:*:*:*", "matchCriteriaId": "8495556A-FE73-4D22-A3F1-367D0D143DBD", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-3040_firmware:1.20b03:*:*:*:*:*:*:*", "matchCriteriaId": "8E2AA7D0-1625-4493-8E18-3B9362466C9B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-3040:a1:*:*:*:*:*:*:*", "matchCriteriaId": "05ACD014-D3EE-4653-91F9-959FB7BD0BC9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-3060_firmware:1.01b07:*:*:*:*:*:*:*", "matchCriteriaId": "26AA9A9D-4690-47C4-AB35-36FF8CD1E887", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-3060_firmware:1.02b03:*:*:*:*:*:*:*", "matchCriteriaId": "3B39D8AC-04D7-40AF-A72D-5ADD5CACA57A", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-3060_firmware:1.11b02:*:*:*:*:*:*:*", "matchCriteriaId": "16BC242D-9BBA-4A67-BCBD-A61CEBC87175", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-3060_firmware:1.11b04:*:*:*:*:*:*:*", "matchCriteriaId": "8C423CCB-73CC-4AE7-B163-F2A0CB4D8817", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-3060:a1:*:*:*:*:*:*:*", "matchCriteriaId": "75CB7C7C-1B0E-4EC8-9FFC-363D2DF1CDBD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-867_firmware:1.10b04:*:*:*:*:*:*:*", "matchCriteriaId": "2C531C05-7DE4-496D-B70B-8EEF56579BF9", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-867_firmware:1.30b07:*:*:*:*:*:*:*", "matchCriteriaId": "06D97D1B-02AC-46A2-AABC-6336B606C131", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-867:-:*:*:*:*:*:*:*", "matchCriteriaId": "94CB6320-D2FB-4405-8C2D-BB59798A0670", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-882_firmware:1.30b06:*:*:*:*:*:*:*", "matchCriteriaId": "ECEECA9D-716E-4C4D-A299-F3BA3D0C790B", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:dir-882_firmware:1.30b10:*:*:*:*:*:*:*", "matchCriteriaId": "E29C868C-B1AD-4C46-99C4-94EEE89CF02A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-882:a1:*:*:*:*:*:*:*", "matchCriteriaId": "90575122-CE47-42E5-BCE3-6444599B16B3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A command injection vulnerability in the protest binary allows an attacker with access to the remote command line interface to execute arbitrary commands as root." }, { "lang": "es", "value": "Una vulnerabilidad de inyecci\u00f3n de comandos en el binario de protesta permite a un atacante con acceso a la interfaz de l\u00ednea de comandos remota ejecutar comandos arbitrarios como root" } ], "id": "CVE-2022-1262", "lastModified": "2024-11-21T06:40:21.910", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-04-11T20:15:18.157", "references": [ { "source": "vulnreport@tenable.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://www.tenable.com/security/research/tra-2022-09" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://www.tenable.com/security/research/tra-2022-09" } ], "sourceIdentifier": "vulnreport@tenable.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
talos-cna@cisco.com | https://talosintelligence.com/vulnerability_reports/TALOS-2021-1282 | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://talosintelligence.com/vulnerability_reports/TALOS-2021-1282 | Exploit, Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
dlink | dir-3040_firmware | 1.13b03 | |
dlink | dir-3040 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-3040_firmware:1.13b03:*:*:*:*:*:*:*", "matchCriteriaId": "8495556A-FE73-4D22-A3F1-367D0D143DBD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-3040:-:*:*:*:*:*:*:*", "matchCriteriaId": "A4EDA686-7BB6-49CB-8370-E0E5F53914A8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An information disclosure vulnerability exists in the Zebra IP Routing Manager functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to the disclosure of sensitive information. An attacker can send a sequence of requests to trigger this vulnerability." }, { "lang": "es", "value": "Se presenta una vulnerabilidad de Divulgaci\u00f3n de Informaci\u00f3n en la funcionalidad Zebra IP Routing Manager de D-LINK DIR-3040 versi\u00f3n 1.13B03. Una petici\u00f3n de red especialmente dise\u00f1ada puede conllevar a la divulgaci\u00f3n de informaci\u00f3n confidencial. Un atacante puede enviar una secuencia de peticiones para activar esta vulnerabilidad" } ], "id": "CVE-2021-21817", "lastModified": "2024-11-21T05:49:02.070", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "talos-cna@cisco.com", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-07-16T11:15:09.937", "references": [ { "source": "talos-cna@cisco.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1282" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1282" } ], "sourceIdentifier": "talos-cna@cisco.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-200" } ], "source": "talos-cna@cisco.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-200" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
talos-cna@cisco.com | https://talosintelligence.com/vulnerability_reports/TALOS-2021-1284 | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://talosintelligence.com/vulnerability_reports/TALOS-2021-1284 | Exploit, Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
dlink | dir-3040_firmware | 1.13b03 | |
dlink | dir-3040 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-3040_firmware:1.13b03:*:*:*:*:*:*:*", "matchCriteriaId": "8495556A-FE73-4D22-A3F1-367D0D143DBD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-3040:-:*:*:*:*:*:*:*", "matchCriteriaId": "A4EDA686-7BB6-49CB-8370-E0E5F53914A8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A code execution vulnerability exists in the Libcli Test Environment functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to arbitrary command execution. An attacker can send a sequence of requests to trigger this vulnerability." }, { "lang": "es", "value": "Se presenta una vulnerabilidad de ejecuci\u00f3n de c\u00f3digo en la funcionalidad de Libcli Test Environment de D-LINK DIR-3040 versi\u00f3n 1.13B03. Una petici\u00f3n de red especialmente dise\u00f1ada puede conllevar a una ejecuci\u00f3n de un comando arbitrario. Un atacante puede enviar una secuencia de peticiones para activar esta vulnerabilidad" } ], "id": "CVE-2021-21819", "lastModified": "2024-11-21T05:49:02.330", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.3, "impactScore": 6.0, "source": "talos-cna@cisco.com", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-07-16T11:15:10.003", "references": [ { "source": "talos-cna@cisco.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1284" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1284" } ], "sourceIdentifier": "talos-cna@cisco.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "talos-cna@cisco.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/flamingo1616/iot_vuln/blob/main/D-Link/DIR-3040/6.md | Exploit, Third Party Advisory | |
cve@mitre.org | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/flamingo1616/iot_vuln/blob/main/D-Link/DIR-3040/6.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory |
Vendor | Product | Version | |
---|---|---|---|
dlink | dir-3040_firmware | 120b03 | |
dlink | dir-3040 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-3040_firmware:120b03:*:*:*:*:*:*:*", "matchCriteriaId": "5EB21CA0-D76B-4D11-83AD-4697C6437438", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-3040:-:*:*:*:*:*:*:*", "matchCriteriaId": "A4EDA686-7BB6-49CB-8370-E0E5F53914A8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "D-Link DIR-3040 device with firmware 120B03 was discovered to contain a command injection vulnerability via the SetTriggerLEDBlink function." }, { "lang": "es", "value": "Se descubri\u00f3 que el dispositivo D-Link DIR-3040 con firmware 120B03 contiene una vulnerabilidad de inyecci\u00f3n de comandos a trav\u00e9s de la funci\u00f3n SetTriggerLEDBlink." } ], "id": "CVE-2022-44832", "lastModified": "2024-11-21T07:28:29.550", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-12-14T15:15:10.467", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/flamingo1616/iot_vuln/blob/main/D-Link/DIR-3040/6.md" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/flamingo1616/iot_vuln/blob/main/D-Link/DIR-3040/6.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.dlink.com/en/security-bulletin/" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
talos-cna@cisco.com | https://talosintelligence.com/vulnerability_reports/TALOS-2021-1361 | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://talosintelligence.com/vulnerability_reports/TALOS-2021-1361 | Exploit, Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
dlink | dir-3040_firmware | 1.13b03 | |
dlink | dir-3040 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-3040_firmware:1.13b03:*:*:*:*:*:*:*", "matchCriteriaId": "8495556A-FE73-4D22-A3F1-367D0D143DBD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-3040:-:*:*:*:*:*:*:*", "matchCriteriaId": "A4EDA686-7BB6-49CB-8370-E0E5F53914A8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An information disclosure vulnerability exists in the WiFi Smart Mesh functionality of D-LINK DIR-3040 1.13B03. A specially-crafted network request can lead to command execution. An attacker can connect to the MQTT service to trigger this vulnerability." }, { "lang": "es", "value": "Se presenta una vulnerabilidad de divulgaci\u00f3n de informaci\u00f3n en la funcionalidad WiFi Smart Mesh de D-LINK DIR-3040 versi\u00f3n 1.13B03. Una petici\u00f3n de red especialmente dise\u00f1ada puede conllevar a una ejecuci\u00f3n de un comando. Un atacante puede conectarse al servicio MQTT para desencadenar esta vulnerabilidad" } ], "id": "CVE-2021-21913", "lastModified": "2024-11-21T05:49:13.897", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 10.0, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 6.0, "source": "talos-cna@cisco.com", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-09-23T15:15:07.527", "references": [ { "source": "talos-cna@cisco.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1361" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1361" } ], "sourceIdentifier": "talos-cna@cisco.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-798" } ], "source": "talos-cna@cisco.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-798" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
talos-cna@cisco.com | https://talosintelligence.com/vulnerability_reports/TALOS-2021-1281 | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://talosintelligence.com/vulnerability_reports/TALOS-2021-1281 | Exploit, Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
dlink | dir-3040_firmware | 1.13b03 | |
dlink | dir-3040 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-3040_firmware:1.13b03:*:*:*:*:*:*:*", "matchCriteriaId": "8495556A-FE73-4D22-A3F1-367D0D143DBD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-3040:-:*:*:*:*:*:*:*", "matchCriteriaId": "A4EDA686-7BB6-49CB-8370-E0E5F53914A8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An information disclosure vulnerability exists in the Syslog functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to the disclosure of sensitive information. An attacker can send an HTTP request to trigger this vulnerability." }, { "lang": "es", "value": "Se presenta una vulnerabilidad de Divulgaci\u00f3n de Informaci\u00f3n en la funcionalidad de Syslog de D-LINK DIR-3040 versi\u00f3n 1.13B03. Una petici\u00f3n de red especialmente dise\u00f1ada puede conllevar a la divulgaci\u00f3n de informaci\u00f3n confidencial. Un atacante puede enviar una petici\u00f3n HTTP para desencadenar esta vulnerabilidad" } ], "id": "CVE-2021-21816", "lastModified": "2024-11-21T05:49:01.937", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "talos-cna@cisco.com", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 1.4, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-07-16T11:15:09.900", "references": [ { "source": "talos-cna@cisco.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1281" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1281" } ], "sourceIdentifier": "talos-cna@cisco.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-200" } ], "source": "talos-cna@cisco.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-200" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
talos-cna@cisco.com | https://talosintelligence.com/vulnerability_reports/TALOS-2021-1285 | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://talosintelligence.com/vulnerability_reports/TALOS-2021-1285 | Exploit, Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
dlink | dir-3040_firmware | 1.13b03 | |
dlink | dir-3040 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dir-3040_firmware:1.13b03:*:*:*:*:*:*:*", "matchCriteriaId": "8495556A-FE73-4D22-A3F1-367D0D143DBD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dir-3040:-:*:*:*:*:*:*:*", "matchCriteriaId": "A4EDA686-7BB6-49CB-8370-E0E5F53914A8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A hard-coded password vulnerability exists in the Libcli Test Environment functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to code execution. An attacker can send a sequence of requests to trigger this vulnerability." }, { "lang": "es", "value": "Se presenta una vulnerabilidad de contrase\u00f1a embebida en la funcionalidad Libcli Test Environment de D-LINK DIR-3040 versi\u00f3n 1.13B03. Una petici\u00f3n de red especialmente dise\u00f1ada puede conllevar a una ejecuci\u00f3n de c\u00f3digo. Un atacante puede enviar una secuencia de peticiones para activar esta vulnerabilidad" } ], "id": "CVE-2021-21820", "lastModified": "2024-11-21T05:49:02.463", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 10.0, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 6.0, "source": "talos-cna@cisco.com", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-07-16T11:15:10.037", "references": [ { "source": "talos-cna@cisco.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1285" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1285" } ], "sourceIdentifier": "talos-cna@cisco.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-798" } ], "source": "talos-cna@cisco.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-798" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
cve-2021-21816
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://talosintelligence.com/vulnerability_reports/TALOS-2021-1281 | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:23:29.523Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1281" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "D-LINK", "vendor": "n/a", "versions": [ { "status": "affected", "version": "D-LINK DIR-3040 1.13B03" } ] } ], "descriptions": [ { "lang": "en", "value": "An information disclosure vulnerability exists in the Syslog functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to the disclosure of sensitive information. An attacker can send an HTTP request to trigger this vulnerability." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-200", "description": "CWE-200: Information Exposure", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-07-16T10:28:42", "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "shortName": "talos" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1281" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "talos-cna@cisco.com", "ID": "CVE-2021-21816", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "D-LINK", "version": { "version_data": [ { "version_value": "D-LINK DIR-3040 1.13B03" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An information disclosure vulnerability exists in the Syslog functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to the disclosure of sensitive information. An attacker can send an HTTP request to trigger this vulnerability." } ] }, "impact": { "cvss": { "baseScore": 6.5, "baseSeverity": "Medium", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-200: Information Exposure" } ] } ] }, "references": { "reference_data": [ { "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1281", "refsource": "MISC", "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1281" } ] } } } }, "cveMetadata": { "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "assignerShortName": "talos", "cveId": "CVE-2021-21816", "datePublished": "2021-07-16T10:28:42", "dateReserved": "2021-01-04T00:00:00", "dateUpdated": "2024-08-03T18:23:29.523Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-1262
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://www.tenable.com/security/research/tra-2022-09 | x_refsource_MISC |
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | D-Link Routers |
Version: DIR-1360 A1 firmware version 1.02B03, DIR-1360 A1 firmware version 1.03B02, DIR-1360 A1 firmware version 1.11B04, DIR-1360 firmware version 1.00B15, DIR-1360 firmware version 1.01B03, DIR-1760 firmware version 1.01B04, DIR-1960 A1 firmware version 1.02B01, DIR-1960 A1 firmware version 1.03B03, DIR-1960 A1 firmware version 1.11B03, DIR-2640 A1 firmware version 1.01B04, DIR-2640 A1 firmware version 1.11B02, DIR-2660 A1 firmware version 1.04B03, DIR-2660 A1 firmware version 1.11B04, DIR-2660 firmware version 1.00B14, DIR-2660 firmware version 1.01B03, DIR-2660 firmware version 1.02B01, DIR-2660 firmware version 1.03B04, DIR-3040 A1 firmware version 1.11B02, DIR-3040 A1 firmware version 1.12B01, DIR-3040 A1 firmware version 1.13B03, DIR-3040 A1 firmware version 1.20B03, DIR-3060 A1 firmware version 1.01B07, DIR-3060 A1 firmware version 1.02B03, DIR-3060 A1 firmware version 1.11B04, DIR-3060 firmware version 1.00B12, DIR-867 A1 firmware version 1.20B10, DIR-867 firmware version 1.10B04, DIR-867 fir ...[truncated*] |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T23:55:24.531Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.tenable.com/security/research/tra-2022-09" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "D-Link Routers", "vendor": "n/a", "versions": [ { "status": "affected", "version": "DIR-1360 A1 firmware version 1.02B03, DIR-1360 A1 firmware version 1.03B02, DIR-1360 A1 firmware version 1.11B04, DIR-1360 firmware version 1.00B15, DIR-1360 firmware version 1.01B03, DIR-1760 firmware version 1.01B04, DIR-1960 A1 firmware version 1.02B01, DIR-1960 A1 firmware version 1.03B03, DIR-1960 A1 firmware version 1.11B03, DIR-2640 A1 firmware version 1.01B04, DIR-2640 A1 firmware version 1.11B02, DIR-2660 A1 firmware version 1.04B03, DIR-2660 A1 firmware version 1.11B04, DIR-2660 firmware version 1.00B14, DIR-2660 firmware version 1.01B03, DIR-2660 firmware version 1.02B01, DIR-2660 firmware version 1.03B04, DIR-3040 A1 firmware version 1.11B02, DIR-3040 A1 firmware version 1.12B01, DIR-3040 A1 firmware version 1.13B03, DIR-3040 A1 firmware version 1.20B03, DIR-3060 A1 firmware version 1.01B07, DIR-3060 A1 firmware version 1.02B03, DIR-3060 A1 firmware version 1.11B04, DIR-3060 firmware version 1.00B12, DIR-867 A1 firmware version 1.20B10, DIR-867 firmware version 1.10B04, DIR-867 fir ...[truncated*]" } ] } ], "descriptions": [ { "lang": "en", "value": "A command injection vulnerability in the protest binary allows an attacker with access to the remote command line interface to execute arbitrary commands as root." } ], "problemTypes": [ { "descriptions": [ { "description": "Command Injection", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-04-11T19:38:13", "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be", "shortName": "tenable" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.tenable.com/security/research/tra-2022-09" } ], "x_ConverterErrors": { "version_name": { "error": "version_name too long. Use array of versions to record more than one version.", "message": "Truncated!" } }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "vulnreport@tenable.com", "ID": "CVE-2022-1262", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "D-Link Routers", "version": { "version_data": [ { "version_value": "DIR-1360 A1 firmware version 1.02B03, DIR-1360 A1 firmware version 1.03B02, DIR-1360 A1 firmware version 1.11B04, DIR-1360 firmware version 1.00B15, DIR-1360 firmware version 1.01B03, DIR-1760 firmware version 1.01B04, DIR-1960 A1 firmware version 1.02B01, DIR-1960 A1 firmware version 1.03B03, DIR-1960 A1 firmware version 1.11B03, DIR-2640 A1 firmware version 1.01B04, DIR-2640 A1 firmware version 1.11B02, DIR-2660 A1 firmware version 1.04B03, DIR-2660 A1 firmware version 1.11B04, DIR-2660 firmware version 1.00B14, DIR-2660 firmware version 1.01B03, DIR-2660 firmware version 1.02B01, DIR-2660 firmware version 1.03B04, DIR-3040 A1 firmware version 1.11B02, DIR-3040 A1 firmware version 1.12B01, DIR-3040 A1 firmware version 1.13B03, DIR-3040 A1 firmware version 1.20B03, DIR-3060 A1 firmware version 1.01B07, DIR-3060 A1 firmware version 1.02B03, DIR-3060 A1 firmware version 1.11B04, DIR-3060 firmware version 1.00B12, DIR-867 A1 firmware version 1.20B10, DIR-867 firmware version 1.10B04, DIR-867 firmware version 1.30B07, DIR-878 firmware version 1.20B05, DIR-878 firmware version 1.30B08, DIR-882 A1 firmware version 1.30B06, DIR-882 A1 firmware version 1.30B10, DIR-882 firmware version 1.20B06" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A command injection vulnerability in the protest binary allows an attacker with access to the remote command line interface to execute arbitrary commands as root." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Command Injection" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.tenable.com/security/research/tra-2022-09", "refsource": "MISC", "url": "https://www.tenable.com/security/research/tra-2022-09" } ] } } } }, "cveMetadata": { "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be", "assignerShortName": "tenable", "cveId": "CVE-2022-1262", "datePublished": "2022-04-11T19:38:13", "dateReserved": "2022-04-06T00:00:00", "dateUpdated": "2024-08-02T23:55:24.531Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-21817
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://talosintelligence.com/vulnerability_reports/TALOS-2021-1282 | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:23:29.562Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1282" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "D-Link", "vendor": "n/a", "versions": [ { "status": "affected", "version": "D-LINK DIR-3040 1.13B03" } ] } ], "descriptions": [ { "lang": "en", "value": "An information disclosure vulnerability exists in the Zebra IP Routing Manager functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to the disclosure of sensitive information. An attacker can send a sequence of requests to trigger this vulnerability." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-200", "description": "CWE-200: Information Exposure", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-07-16T10:24:30", "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "shortName": "talos" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1282" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "talos-cna@cisco.com", "ID": "CVE-2021-21817", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "D-Link", "version": { "version_data": [ { "version_value": "D-LINK DIR-3040 1.13B03" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An information disclosure vulnerability exists in the Zebra IP Routing Manager functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to the disclosure of sensitive information. An attacker can send a sequence of requests to trigger this vulnerability." } ] }, "impact": { "cvss": { "baseScore": 7.5, "baseSeverity": "High", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-200: Information Exposure" } ] } ] }, "references": { "reference_data": [ { "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1282", "refsource": "MISC", "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1282" } ] } } } }, "cveMetadata": { "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "assignerShortName": "talos", "cveId": "CVE-2021-21817", "datePublished": "2021-07-16T10:24:30", "dateReserved": "2021-01-04T00:00:00", "dateUpdated": "2024-08-03T18:23:29.562Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-21818
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://talosintelligence.com/vulnerability_reports/TALOS-2021-1283 | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:23:29.485Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1283" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "D-Link", "vendor": "n/a", "versions": [ { "status": "affected", "version": "D-LINK DIR-3040 1.13B03" } ] } ], "descriptions": [ { "lang": "en", "value": "A hard-coded password vulnerability exists in the Zebra IP Routing Manager functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to a denial of service. An attacker can send a sequence of requests to trigger this vulnerability." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-259", "description": "CWE-259: Use of Hard-coded Password", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-07-16T10:24:20", "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "shortName": "talos" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1283" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "talos-cna@cisco.com", "ID": "CVE-2021-21818", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "D-Link", "version": { "version_data": [ { "version_value": "D-LINK DIR-3040 1.13B03" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A hard-coded password vulnerability exists in the Zebra IP Routing Manager functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to a denial of service. An attacker can send a sequence of requests to trigger this vulnerability." } ] }, "impact": { "cvss": { "baseScore": 7.5, "baseSeverity": "High", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-259: Use of Hard-coded Password" } ] } ] }, "references": { "reference_data": [ { "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1283", "refsource": "MISC", "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1283" } ] } } } }, "cveMetadata": { "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "assignerShortName": "talos", "cveId": "CVE-2021-21818", "datePublished": "2021-07-16T10:24:20", "dateReserved": "2021-01-04T00:00:00", "dateUpdated": "2024-08-03T18:23:29.485Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-21820
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://talosintelligence.com/vulnerability_reports/TALOS-2021-1285 | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:23:29.512Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1285" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "D-Link", "vendor": "n/a", "versions": [ { "status": "affected", "version": "D-LINK DIR-3040 1.13B03" } ] } ], "descriptions": [ { "lang": "en", "value": "A hard-coded password vulnerability exists in the Libcli Test Environment functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to code execution. An attacker can send a sequence of requests to trigger this vulnerability." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 10, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-798", "description": "CWE-798: Use of Hard-coded Credentials", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-07-16T10:24:07", "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "shortName": "talos" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1285" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "talos-cna@cisco.com", "ID": "CVE-2021-21820", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "D-Link", "version": { "version_data": [ { "version_value": "D-LINK DIR-3040 1.13B03" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A hard-coded password vulnerability exists in the Libcli Test Environment functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to code execution. An attacker can send a sequence of requests to trigger this vulnerability." } ] }, "impact": { "cvss": { "baseScore": 10, "baseSeverity": null, "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-798: Use of Hard-coded Credentials" } ] } ] }, "references": { "reference_data": [ { "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1285", "refsource": "MISC", "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1285" } ] } } } }, "cveMetadata": { "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "assignerShortName": "talos", "cveId": "CVE-2021-21820", "datePublished": "2021-07-16T10:24:07", "dateReserved": "2021-01-04T00:00:00", "dateUpdated": "2024-08-03T18:23:29.512Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-43648
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T13:40:06.208Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-052/" }, { "tags": [ "x_transferred" ], "url": "https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10322" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-43648", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-12T16:59:00.683908Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-12T16:59:05.029Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "DIR-3040", "vendor": "D-Link", "versions": [ { "status": "affected", "version": "1.20B03" } ] } ], "credits": [ { "lang": "en", "value": "Nicholas Zubrisky" } ], "descriptions": [ { "lang": "en", "value": "This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of D-Link DIR-3040 1.20B03 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the MiniDLNA service. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the MiniDLNA service. Was ZDI-CAN-19910." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-122", "description": "CWE-122: Heap-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-03-29T00:00:00.000Z", "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "shortName": "zdi" }, "references": [ { "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-052/" }, { "url": "https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10322" } ] } }, "cveMetadata": { "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "assignerShortName": "zdi", "cveId": "CVE-2022-43648", "datePublished": "2023-03-29T00:00:00.000Z", "dateReserved": "2022-10-21T00:00:00.000Z", "dateUpdated": "2025-02-12T16:59:05.029Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-44832
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T14:01:31.305Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "tags": [ "x_transferred" ], "url": "https://github.com/flamingo1616/iot_vuln/blob/main/D-Link/DIR-3040/6.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "D-Link DIR-3040 device with firmware 120B03 was discovered to contain a command injection vulnerability via the SetTriggerLEDBlink function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-14T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://www.dlink.com/en/security-bulletin/" }, { "url": "https://github.com/flamingo1616/iot_vuln/blob/main/D-Link/DIR-3040/6.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-44832", "datePublished": "2022-12-14T00:00:00", "dateReserved": "2022-11-07T00:00:00", "dateUpdated": "2024-08-03T14:01:31.305Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-21913
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://talosintelligence.com/vulnerability_reports/TALOS-2021-1361 | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:30:22.881Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1361" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "D-Link", "vendor": "n/a", "versions": [ { "status": "affected", "version": "D-LINK DIR-3040 1.13B03" } ] } ], "descriptions": [ { "lang": "en", "value": "An information disclosure vulnerability exists in the WiFi Smart Mesh functionality of D-LINK DIR-3040 1.13B03. A specially-crafted network request can lead to command execution. An attacker can connect to the MQTT service to trigger this vulnerability." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 10, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-798", "description": "CWE-798: Use of Hard-coded Credentials", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-09-23T14:48:36", "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "shortName": "talos" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1361" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "talos-cna@cisco.com", "ID": "CVE-2021-21913", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "D-Link", "version": { "version_data": [ { "version_value": "D-LINK DIR-3040 1.13B03" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An information disclosure vulnerability exists in the WiFi Smart Mesh functionality of D-LINK DIR-3040 1.13B03. A specially-crafted network request can lead to command execution. An attacker can connect to the MQTT service to trigger this vulnerability." } ] }, "impact": { "cvss": { "baseScore": 10, "baseSeverity": null, "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-798: Use of Hard-coded Credentials" } ] } ] }, "references": { "reference_data": [ { "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1361", "refsource": "MISC", "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1361" } ] } } } }, "cveMetadata": { "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "assignerShortName": "talos", "cveId": "CVE-2021-21913", "datePublished": "2021-09-23T14:48:37", "dateReserved": "2021-01-04T00:00:00", "dateUpdated": "2024-08-03T18:30:22.881Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-21819
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://talosintelligence.com/vulnerability_reports/TALOS-2021-1284 | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:23:29.549Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1284" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "D-Link", "vendor": "n/a", "versions": [ { "status": "affected", "version": "D-LINK DIR-3040 1.13B03" } ] } ], "descriptions": [ { "lang": "en", "value": "A code execution vulnerability exists in the Libcli Test Environment functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to arbitrary command execution. An attacker can send a sequence of requests to trigger this vulnerability." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-07-16T10:24:13", "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "shortName": "talos" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1284" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "talos-cna@cisco.com", "ID": "CVE-2021-21819", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "D-Link", "version": { "version_data": [ { "version_value": "D-LINK DIR-3040 1.13B03" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A code execution vulnerability exists in the Libcli Test Environment functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to arbitrary command execution. An attacker can send a sequence of requests to trigger this vulnerability." } ] }, "impact": { "cvss": { "baseScore": 9.1, "baseSeverity": "Critical", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1284", "refsource": "MISC", "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1284" } ] } } } }, "cveMetadata": { "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "assignerShortName": "talos", "cveId": "CVE-2021-21819", "datePublished": "2021-07-16T10:24:13", "dateReserved": "2021-01-04T00:00:00", "dateUpdated": "2024-08-03T18:23:29.549Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }