Vulnerabilites related to dlink - dir-300
var-202305-2256
Vulnerability from variot

D-Link DIR-300 firmware <=REVA1.06 and <=REVB2.06 is vulnerable to File inclusion via /model/__lang_msg.php. D-Link Systems, Inc. of DIR-300 There are unspecified vulnerabilities in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202305-2256",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "dir-300",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.06"
      },
      {
        "model": "dir-300",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2.06"
      },
      {
        "model": "dir-300",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "d link",
        "version": "dir-300  firmware  2.06  and earlier"
      },
      {
        "model": "dir-300",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dir-300",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "d link",
        "version": "dir-300  firmware  1.06  and earlier"
      },
      {
        "model": "dir-300",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-010965"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-31814"
      }
    ]
  },
  "cve": "CVE-2023-31814",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2023-31814",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2023-31814",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-31814",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2023-31814",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202305-2017",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-010965"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-2017"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-31814"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "D-Link DIR-300 firmware \u003c=REVA1.06 and \u003c=REVB2.06 is vulnerable to File inclusion via /model/__lang_msg.php. D-Link Systems, Inc. of DIR-300 There are unspecified vulnerabilities in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-31814"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-010965"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-31814"
      }
    ],
    "trust": 1.71
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-31814",
        "trust": 3.3
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-010965",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-2017",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-31814",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2023-31814"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-010965"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-2017"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-31814"
      }
    ]
  },
  "id": "VAR-202305-2256",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.7
  },
  "last_update_date": "2024-08-14T15:32:03.141000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "NVD-CWE-Other",
        "trust": 1.0
      },
      {
        "problemtype": "others (CWE-Other) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-010965"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-31814"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://www.dlink.com/en/security-bulletin/"
      },
      {
        "trust": 2.5,
        "url": "https://gist.github.com/1915504804/9503198d3cbd5bc7db47625ac0caaade"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-31814"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2023-31814/"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2023-31814"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-010965"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-2017"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-31814"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULMON",
        "id": "CVE-2023-31814"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-010965"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-2017"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-31814"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-05-23T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-31814"
      },
      {
        "date": "2023-12-12T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-010965"
      },
      {
        "date": "2023-05-23T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202305-2017"
      },
      {
        "date": "2023-05-23T01:15:10.087000",
        "db": "NVD",
        "id": "CVE-2023-31814"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-05-23T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-31814"
      },
      {
        "date": "2023-12-12T01:18:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-010965"
      },
      {
        "date": "2023-05-31T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202305-2017"
      },
      {
        "date": "2023-05-30T19:00:27.487000",
        "db": "NVD",
        "id": "CVE-2023-31814"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-2017"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "D-Link\u00a0Systems,\u00a0Inc.\u00a0 of \u00a0DIR-300\u00a0 Firmware vulnerabilities",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-010965"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-2017"
      }
    ],
    "trust": 0.6
  }
}

var-202408-0547
Vulnerability from variot

D-Link DIR-300 REVA FIRMWARE v1.06B05_WW contains hardcoded credentials in the Telnet service. D-Link Systems, Inc. of DIR-300 A vulnerability exists in the firmware regarding the use of hardcoded credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202408-0547",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "dir-300",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.06b05_ww"
      },
      {
        "model": "dir-300",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "d link",
        "version": "dir-300  firmware  1.06b05 ww"
      },
      {
        "model": "dir-300",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dir-300",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-005489"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-41616"
      }
    ]
  },
  "cve": "CVE-2024-41616",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2024-41616",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2024-41616",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2024-41616",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2024-41616",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "id": "CVE-2024-41616",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2024-41616",
            "trust": 0.8,
            "value": "Critical"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-005489"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-41616"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-41616"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "D-Link DIR-300 REVA FIRMWARE v1.06B05_WW contains hardcoded credentials in the Telnet service. D-Link Systems, Inc. of DIR-300 A vulnerability exists in the firmware regarding the use of hardcoded credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-41616"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-005489"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-41616",
        "trust": 2.6
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-005489",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-005489"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-41616"
      }
    ]
  },
  "id": "VAR-202408-0547",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.7
  },
  "last_update_date": "2024-08-22T03:42:56.759000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-798",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-259",
        "trust": 1.0
      },
      {
        "problemtype": "Use hard-coded credentials (CWE-798) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-005489"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-41616"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/lyaobol/iotsec/blob/main/d-link/dir300/cve-2024-41616"
      },
      {
        "trust": 1.8,
        "url": "https://github.com/lyaobol/iotsec/blob/main/d-link/dir300/d-link300.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2024-41616"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-005489"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-41616"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-005489"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-41616"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-08-16T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-005489"
      },
      {
        "date": "2024-08-06T16:15:49.260000",
        "db": "NVD",
        "id": "CVE-2024-41616"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-08-16T04:58:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-005489"
      },
      {
        "date": "2024-08-07T20:54:20.793000",
        "db": "NVD",
        "id": "CVE-2024-41616"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "D-Link\u00a0Systems,\u00a0Inc.\u00a0 of \u00a0DIR-300\u00a0 Vulnerability related to use of hardcoded credentials in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-005489"
      }
    ],
    "trust": 0.8
  }
}

var-202401-0959
Vulnerability from variot

A vulnerability classified as critical was found in D-Link DAP-1360, DIR-300, DIR-615, DIR-615GF, DIR-615S, DIR-615T, DIR-620, DIR-620S, DIR-806A, DIR-815, DIR-815AC, DIR-815S, DIR-816, DIR-820, DIR-822, DIR-825, DIR-825AC, DIR-825ACF, DIR-825ACG1, DIR-841, DIR-842, DIR-842S, DIR-843, DIR-853, DIR-878, DIR-882, DIR-1210, DIR-1260, DIR-2150, DIR-X1530, DIR-X1860, DSL-224, DSL-245GR, DSL-2640U, DSL-2750U, DSL-G2452GR, DVG-5402G, DVG-5402G, DVG-5402GFRU, DVG-N5402G, DVG-N5402G-IL, DWM-312W, DWM-321, DWR-921, DWR-953 and Good Line Router v2 up to 20240112. This vulnerability affects unknown code of the file /devinfo of the component HTTP GET Request Handler. The manipulation of the argument area with the input notice|net|version leads to information disclosure. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-251542 is the identifier assigned to this vulnerability. dir-825acg1 firmware, DIR-841 firmware, dir-1260 firmware etc. D-Link Systems, Inc. There are unspecified vulnerabilities in the product.Information may be obtained

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202401-0959",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "dir-x1860",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dir-878",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dsl-224",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dap-1360",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dvg-5402g",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dir-615",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dir-820",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dwm-321",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dsl-2640u",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dir-620",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dir-x1530",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dir-815\\/ac",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dir-815s",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dir-1260",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dir-842",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dwr-953",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dir-841",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dir-816",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dir-842s",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dir-1210",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dir-615gf",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dir-620s",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dir-825acf",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dir-615t",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dir-815",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dir-825",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dir-853",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dir-822",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dir-882",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dsl-2750u",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dwr-921",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dir-825acg1",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dir-825ac",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dsl-245gr",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dir-806a",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dvg-n5402g",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dsl-g2452gr",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dir-300",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dwm-312w",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dir-843",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dvg-n5402g\\/il",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dir-2150",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dir-615s",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dvg-5402g\\/gfru",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2024-01-12"
      },
      {
        "model": "dir-825",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dir-615t",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dir-825acf",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dir-825acg1",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dir-x1530",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dir-842s",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dir-853",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dir-1210",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dir-1260",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dir-615",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dir-806a",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dir-815",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dir-841",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dir-815s",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dir-842",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dir-878",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dsl-g2452gr",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dir-822",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dsl-245gr",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dir-300",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001679"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0717"
      }
    ]
  },
  "cve": "CVE-2024-0717",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2024-0717",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 3.9,
            "id": "CVE-2024-0717",
            "impactScore": 1.4,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 2.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 5.3,
            "baseSeverity": "Medium",
            "confidentialityImpact": "Low",
            "exploitabilityScore": null,
            "id": "CVE-2024-0717",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2024-0717",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2024-0717",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2024-0717",
            "trust": 0.8,
            "value": "Medium"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001679"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0717"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0717"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability classified as critical was found in D-Link DAP-1360, DIR-300, DIR-615, DIR-615GF, DIR-615S, DIR-615T, DIR-620, DIR-620S, DIR-806A, DIR-815, DIR-815AC, DIR-815S, DIR-816, DIR-820, DIR-822, DIR-825, DIR-825AC, DIR-825ACF, DIR-825ACG1, DIR-841, DIR-842, DIR-842S, DIR-843, DIR-853, DIR-878, DIR-882, DIR-1210, DIR-1260, DIR-2150, DIR-X1530, DIR-X1860, DSL-224, DSL-245GR, DSL-2640U, DSL-2750U, DSL-G2452GR, DVG-5402G, DVG-5402G, DVG-5402GFRU, DVG-N5402G, DVG-N5402G-IL, DWM-312W, DWM-321, DWR-921, DWR-953 and Good Line Router v2 up to 20240112. This vulnerability affects unknown code of the file /devinfo of the component HTTP GET Request Handler. The manipulation of the argument area with the input notice|net|version leads to information disclosure. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-251542 is the identifier assigned to this vulnerability. dir-825acg1 firmware, DIR-841 firmware, dir-1260 firmware etc. D-Link Systems, Inc. There are unspecified vulnerabilities in the product.Information may be obtained",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-0717"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001679"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-0717",
        "trust": 2.6
      },
      {
        "db": "VULDB",
        "id": "251542",
        "trust": 1.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001679",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001679"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0717"
      }
    ]
  },
  "id": "VAR-202401-0959",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.538983995625
  },
  "last_update_date": "2024-08-14T15:15:35.797000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-200",
        "trust": 1.0
      },
      {
        "problemtype": "NVD-CWE-noinfo",
        "trust": 1.0
      },
      {
        "problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001679"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0717"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/999zzzzz/d-link"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?ctiid.251542"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?id.251542"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2024-0717"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001679"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0717"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001679"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0717"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-02-06T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-001679"
      },
      {
        "date": "2024-01-19T16:15:11.190000",
        "db": "NVD",
        "id": "CVE-2024-0717"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-02-06T01:48:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-001679"
      },
      {
        "date": "2024-05-17T02:34:53.200000",
        "db": "NVD",
        "id": "CVE-2024-0717"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural \u00a0D-Link\u00a0Systems,\u00a0Inc.\u00a0 Product vulnerabilities",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001679"
      }
    ],
    "trust": 0.8
  }
}

var-201112-0187
Vulnerability from variot

The D-Link DIR-300 router stores cleartext passwords, which allows context-dependent attackers to obtain sensitive information via unspecified vectors. D-Link is a network company founded by Taiwan D-Link Group, dedicated to the R&D, production and marketing of LAN, broadband network, wireless network, voice network and related network equipment. D-Link DIR-300 routers are vulnerable to encryption issues

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201112-0187",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "dir-300",
        "scope": null,
        "trust": 1.4,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dir-300",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-003481"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201112-376"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4723"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/h:d-link:dir-300",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-003481"
      }
    ]
  },
  "cve": "CVE-2011-4723",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CVE-2011-4723",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "VHN-52668",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:S/C:C/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2011-4723",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2011-4723",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201112-376",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-52668",
            "trust": 0.1,
            "value": "MEDIUM"
          },
          {
            "author": "VULMON",
            "id": "CVE-2011-4723",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-52668"
      },
      {
        "db": "VULMON",
        "id": "CVE-2011-4723"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-003481"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201112-376"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4723"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "The D-Link DIR-300 router stores cleartext passwords, which allows context-dependent attackers to obtain sensitive information via unspecified vectors. D-Link is a network company founded by Taiwan D-Link Group, dedicated to the R\u0026D, production and marketing of LAN, broadband network, wireless network, voice network and related network equipment. D-Link DIR-300 routers are vulnerable to encryption issues",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2011-4723"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-003481"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52668"
      },
      {
        "db": "VULMON",
        "id": "CVE-2011-4723"
      }
    ],
    "trust": 1.8
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2011-4723",
        "trust": 2.6
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-003481",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201112-376",
        "trust": 0.7
      },
      {
        "db": "VULHUB",
        "id": "VHN-52668",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2011-4723",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-52668"
      },
      {
        "db": "VULMON",
        "id": "CVE-2011-4723"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-003481"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201112-376"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4723"
      }
    ]
  },
  "id": "VAR-201112-0187",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-52668"
      }
    ],
    "trust": 0.7999999999999999
  },
  "last_update_date": "2024-11-23T22:18:56.500000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "http://www.dlink.com"
      },
      {
        "title": "D-Link DIR-300 Repair Measures for Router Encryption Vulnerabilities",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=234980"
      },
      {
        "title": "Known Exploited Vulnerabilities Detector",
        "trust": 0.1,
        "url": "https://github.com/Ostorlab/KEV "
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2011-4723"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-003481"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201112-376"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-310",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-52668"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-003481"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4723"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "http://en.securitylab.ru/lab/pt-2011-30"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2011-4723"
      },
      {
        "trust": 0.8,
        "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2011-4723"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/310.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://github.com/ostorlab/kev"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-52668"
      },
      {
        "db": "VULMON",
        "id": "CVE-2011-4723"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-003481"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201112-376"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4723"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-52668"
      },
      {
        "db": "VULMON",
        "id": "CVE-2011-4723"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-003481"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201112-376"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4723"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2011-12-20T00:00:00",
        "db": "VULHUB",
        "id": "VHN-52668"
      },
      {
        "date": "2011-12-20T00:00:00",
        "db": "VULMON",
        "id": "CVE-2011-4723"
      },
      {
        "date": "2011-12-21T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2011-003481"
      },
      {
        "date": "2011-12-21T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201112-376"
      },
      {
        "date": "2011-12-20T11:55:08.413000",
        "db": "NVD",
        "id": "CVE-2011-4723"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2011-12-20T00:00:00",
        "db": "VULHUB",
        "id": "VHN-52668"
      },
      {
        "date": "2023-04-26T00:00:00",
        "db": "VULMON",
        "id": "CVE-2011-4723"
      },
      {
        "date": "2011-12-21T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2011-003481"
      },
      {
        "date": "2023-04-27T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201112-376"
      },
      {
        "date": "2024-11-21T01:32:51.950000",
        "db": "NVD",
        "id": "CVE-2011-4723"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201112-376"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "D-Link DIR-300 Vulnerability to obtain important information in router",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-003481"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "encryption problem",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201112-376"
      }
    ],
    "trust": 0.6
  }
}

var-201906-0703
Vulnerability from variot

An issue was discovered in soap.cgi?service=WANIPConn1 on D-Link DIR-845 before v1.02b03, DIR-600 before v2.17b01, DIR-645 before v1.04b11, DIR-300 rev. B, and DIR-865 devices. There is Command Injection via shell metacharacters in the NewInternalClient, NewExternalPort, or NewInternalPort element of a SOAP POST request. plural D-Link The product contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. D-Link DIR-845 and so on are all wireless routers from Taiwan D-Link.

Command injection vulnerability exists in soap.cgi? Service = WANIPConn1 URL in multiple D-Link products. The vulnerability stems from the fact that the network system or product did not properly filter the special elements in the process of constructing executable commands from external input data. An attacker could use this vulnerability to execute an illegal command. The following products and versions are affected: D-Link DIR-845 prior to v1.02b03; DIR-600 prior to v2.17b01; DIR-645 prior to v1.04b11; DIR-300 (rev

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201906-0703",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "dir-300",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2.14b01"
      },
      {
        "model": "dir-845",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.02b03"
      },
      {
        "model": "dir-600",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2.17b01"
      },
      {
        "model": "dir-865",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.05b03"
      },
      {
        "model": "dir-645",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.04b11"
      },
      {
        "model": "dir-300",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dir-600",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "d link",
        "version": "2.17b01"
      },
      {
        "model": "dir-645",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "d link",
        "version": "1.04b11"
      },
      {
        "model": "dir-845",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "d link",
        "version": "1.02b03"
      },
      {
        "model": "dir-865",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dir-600 \u003cv2.17b01",
        "scope": null,
        "trust": 0.6,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dir-645 \u003cv1.04b11",
        "scope": null,
        "trust": 0.6,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dir-845 \u003cv1.02b03",
        "scope": null,
        "trust": 0.6,
        "vendor": "d link",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-39561"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2013-006844"
      },
      {
        "db": "NVD",
        "id": "CVE-2013-7471"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:d-link:dir-300_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dir-600_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dir-645_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dir-845_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dir-865_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2013-006844"
      }
    ]
  },
  "cve": "CVE-2013-7471",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2013-7471",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.9,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-39561",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "VHN-67473",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2013-7471",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2013-7471",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2013-7471",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2013-7471",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-39561",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201906-399",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-67473",
            "trust": 0.1,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2013-7471",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-39561"
      },
      {
        "db": "VULHUB",
        "id": "VHN-67473"
      },
      {
        "db": "VULMON",
        "id": "CVE-2013-7471"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2013-006844"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-399"
      },
      {
        "db": "NVD",
        "id": "CVE-2013-7471"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered in soap.cgi?service=WANIPConn1 on D-Link DIR-845 before v1.02b03, DIR-600 before v2.17b01, DIR-645 before v1.04b11, DIR-300 rev. B, and DIR-865 devices. There is Command Injection via shell metacharacters in the NewInternalClient, NewExternalPort, or NewInternalPort element of a SOAP POST request. plural D-Link The product contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. D-Link DIR-845 and so on are all wireless routers from Taiwan D-Link. \n\nCommand injection vulnerability exists in soap.cgi? Service = WANIPConn1 URL in multiple D-Link products. The vulnerability stems from the fact that the network system or product did not properly filter the special elements in the process of constructing executable commands from external input data. An attacker could use this vulnerability to execute an illegal command. The following products and versions are affected: D-Link DIR-845 prior to v1.02b03; DIR-600 prior to v2.17b01; DIR-645 prior to v1.04b11; DIR-300 (rev",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2013-7471"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2013-006844"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-39561"
      },
      {
        "db": "VULHUB",
        "id": "VHN-67473"
      },
      {
        "db": "VULMON",
        "id": "CVE-2013-7471"
      }
    ],
    "trust": 2.34
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2013-7471",
        "trust": 3.2
      },
      {
        "db": "EXPLOIT-DB",
        "id": "27044",
        "trust": 2.4
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2013-006844",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-399",
        "trust": 0.7
      },
      {
        "db": "EXPLOITDB",
        "id": "27044",
        "trust": 0.6
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-39561",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-67473",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2013-7471",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-39561"
      },
      {
        "db": "VULHUB",
        "id": "VHN-67473"
      },
      {
        "db": "VULMON",
        "id": "CVE-2013-7471"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2013-006844"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-399"
      },
      {
        "db": "NVD",
        "id": "CVE-2013-7471"
      }
    ]
  },
  "id": "VAR-201906-0703",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-39561"
      },
      {
        "db": "VULHUB",
        "id": "VHN-67473"
      }
    ],
    "trust": 1.4161706425
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-39561"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:06:10.235000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "http://us.dlink.com/"
      },
      {
        "title": "Patch for Command injection vulnerability in multiple D-Link products",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/189043"
      },
      {
        "title": "Multiple D-Link Product Command Injection Vulnerability Fixes",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=93638"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-39561"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2013-006844"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-399"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-77",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-67473"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2013-006844"
      },
      {
        "db": "NVD",
        "id": "CVE-2013-7471"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.6,
        "url": "http://www.s3cur1ty.de/m1adv2013-020"
      },
      {
        "trust": 2.4,
        "url": "https://www.exploit-db.com/exploits/27044"
      },
      {
        "trust": 2.0,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2013-7471"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2013-7471"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/77.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-39561"
      },
      {
        "db": "VULHUB",
        "id": "VHN-67473"
      },
      {
        "db": "VULMON",
        "id": "CVE-2013-7471"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2013-006844"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-399"
      },
      {
        "db": "NVD",
        "id": "CVE-2013-7471"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-39561"
      },
      {
        "db": "VULHUB",
        "id": "VHN-67473"
      },
      {
        "db": "VULMON",
        "id": "CVE-2013-7471"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2013-006844"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-399"
      },
      {
        "db": "NVD",
        "id": "CVE-2013-7471"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-11-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-39561"
      },
      {
        "date": "2019-06-11T00:00:00",
        "db": "VULHUB",
        "id": "VHN-67473"
      },
      {
        "date": "2019-06-11T00:00:00",
        "db": "VULMON",
        "id": "CVE-2013-7471"
      },
      {
        "date": "2019-06-20T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2013-006844"
      },
      {
        "date": "2019-06-11T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201906-399"
      },
      {
        "date": "2019-06-11T21:29:00.397000",
        "db": "NVD",
        "id": "CVE-2013-7471"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-11-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-39561"
      },
      {
        "date": "2019-06-12T00:00:00",
        "db": "VULHUB",
        "id": "VHN-67473"
      },
      {
        "date": "2021-04-23T00:00:00",
        "db": "VULMON",
        "id": "CVE-2013-7471"
      },
      {
        "date": "2019-06-20T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2013-006844"
      },
      {
        "date": "2019-06-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201906-399"
      },
      {
        "date": "2024-11-21T02:01:05.363000",
        "db": "NVD",
        "id": "CVE-2013-7471"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-399"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  D-Link Command injection vulnerability in the product",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2013-006844"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "command injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201906-399"
      }
    ],
    "trust": 0.6
  }
}

Vulnerability from fkie_nvd
Published
2024-01-19 16:15
Modified
2024-11-21 08:47
Summary
A vulnerability classified as critical was found in D-Link DAP-1360, DIR-300, DIR-615, DIR-615GF, DIR-615S, DIR-615T, DIR-620, DIR-620S, DIR-806A, DIR-815, DIR-815AC, DIR-815S, DIR-816, DIR-820, DIR-822, DIR-825, DIR-825AC, DIR-825ACF, DIR-825ACG1, DIR-841, DIR-842, DIR-842S, DIR-843, DIR-853, DIR-878, DIR-882, DIR-1210, DIR-1260, DIR-2150, DIR-X1530, DIR-X1860, DSL-224, DSL-245GR, DSL-2640U, DSL-2750U, DSL-G2452GR, DVG-5402G, DVG-5402G, DVG-5402GFRU, DVG-N5402G, DVG-N5402G-IL, DWM-312W, DWM-321, DWR-921, DWR-953 and Good Line Router v2 up to 20240112. This vulnerability affects unknown code of the file /devinfo of the component HTTP GET Request Handler. The manipulation of the argument area with the input notice|net|version leads to information disclosure. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-251542 is the identifier assigned to this vulnerability.
Impacted products
Vendor Product Version
dlink dir-825acg1_firmware *
dlink dir-825acg1 -
dlink dir-841_firmware *
dlink dir-841 -
dlink dir-1260_firmware *
dlink dir-1260 -
dlink dir-822_firmware *
dlink dir-822 -
dlink dir-x1530_firmware *
dlink dir-x1530 -
dlink dir-825_firmware *
dlink dir-825 -
dlink dir-615_firmware *
dlink dir-615 -
dlink dir-842_firmware *
dlink dir-842 -
dlink dir-853_firmware *
dlink dir-853 -
dlink dir-1210_firmware *
dlink dir-1210 -
dlink dir-806a_firmware *
dlink dir-806a -
dlink dir-815_firmware *
dlink dir-815 -
dlink dsl-245gr_firmware *
dlink dsl-245gr -
dlink dsl-g2452gr_firmware *
dlink dsl-g2452gr -
dlink dir-878_firmware *
dlink dir-878 -
dlink dir-825acf_firmware *
dlink dir-825acf -
dlink dir-615t_firmware *
dlink dir-615t -
dlink dir-300_firmware *
dlink dir-300 -
dlink dir-842s_firmware *
dlink dir-842s -
dlink dir-815s_firmware *
dlink dir-815s -
dlink dsl-2640u_firmware *
dlink dsl-2640u -
dlink dir-2150_firmware *
dlink dir-2150 -
dlink dwr-921_firmware *
dlink dwr-921 -
dlink dir-615s_firmware *
dlink dir-615s -
dlink dir-620_firmware *
dlink dir-620 -
dlink dvg-5402g_firmware *
dlink dvg-5402g -
dlink dir-882_firmware *
dlink dir-882 -
dlink dwm-312w_firmware *
dlink dwm-312w -
dlink dir-815\/ac_firmware *
dlink dir-815\/ac -
dlink dsl-224_firmware *
dlink dsl-224 -
dlink dwm-321_firmware *
dlink dwm-321 -
dlink dir-x1860_firmware *
dlink dir-x1860 -
dlink dap-1360_firmware *
dlink dap-1360 -
dlink dir-820_firmware *
dlink dir-820 -
dlink dir-843_firmware *
dlink dir-843 -
dlink dvg-5402g\/gfru_firmware *
dlink dvg-5402g\/gfru -
dlink dwr-953_firmware *
dlink dwr-953 -
dlink dvg-n5402g\/il_firmware *
dlink dvg-n5402g\/il -
dlink dir-825ac_firmware *
dlink dir-825ac -
dlink dir-620s_firmware *
dlink dir-620s -
dlink dvg-n5402g_firmware *
dlink dvg-n5402g -
dlink dsl-2750u_firmware *
dlink dsl-2750u -
dlink dir-615gf_firmware *
dlink dir-615gf -
dlink dir-816_firmware *
dlink dir-816 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-825acg1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "81B11B0F-8307-4845-A322-2CB3FE85840D",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-825acg1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "129E5D3B-B94F-4F33-B64C-35115AFB1165",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-841_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2F4A6809-F1A7-416B-9345-9F7A37B7BF71",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-841:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D789C69F-5063-43B7-AB71-5B0C9294D55E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-1260_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "19167352-59AF-4D47-BC80-A1599F24DE0A",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-1260:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AF5C311E-DB22-452B-BC26-265E3A84B57C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-822_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9867D17E-123A-4A33-A058-12BF1AC453F8",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-822:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B3894F0E-37F8-4A89-87AC-1DB524D4AE04",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-x1530_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2899DF29-FDF6-4D57-8846-3DADCC5349A0",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-x1530:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7FF2C35C-8C59-4D36-8CC9-AE03853B40D4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-825_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6CCF939D-719A-4682-ADD8-C1DE484E5377",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-825:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7038F8A9-03F3-4442-B371-84801EF05447",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-615_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9302B88E-28ED-486C-9E64-D38B9B857E89",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-615:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2E92E959-C211-4979-A233-163BEFCF6F0D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-842_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5039D893-1396-42D0-91D9-2E02B974EF98",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-842:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C05AE997-7966-4CCA-B58A-93B684D55F60",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-853_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9001FB50-6B3D-4EE2-BC9F-920DE95BDC58",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-853:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "332F4880-9D76-4C74-95DE-730F72879EC4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-1210_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F28A25B0-D5E9-4668-B00A-F4F2B34C7457",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-1210:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "28A60F07-0DA7-47AD-B3C0-E1F6ED630C89",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-806a_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CEAC2985-B6E3-4215-8BA5-B6653BCB5EC6",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-806a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "926B41A6-009F-444D-BE5C-B517F844E99B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-815_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "02D27414-7D38-40A6-978B-6A9417A2D09C",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-815:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "50618B63-304B-4A61-AA50-5154E8690E88",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dsl-245gr_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA077FA3-FA87-4B2D-897E-A7B1A7BC7642",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dsl-245gr:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8DF8EB08-A378-4F14-ADD9-E97C244DD80D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dsl-g2452gr_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DB2BFA6C-D260-4B9F-952A-E185BCD0F415",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dsl-g2452gr:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "517C1250-268D-45A7-9BD1-EACE4BA1BA82",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-878_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2DAE783-B0F3-4765-A7FD-945F041369E7",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-878:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D288C73-F89A-47FF-AF11-143C3DFDF942",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-825acf_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D626BD4C-D4D2-4CC5-91EF-AF938A5C1983",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-825acf:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD011B62-C988-463A-8672-F5BD0D984179",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-615t_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4477BE0A-BC4A-4534-8FED-3045CD373008",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-615t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "951C4DD2-B472-401B-A1FF-4FE5957A5213",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-300_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "87DB97AC-CBBA-422D-8DE3-E82DC1D73A98",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-300:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AC2143B3-B3A0-41D6-B8F7-78CE40B1759C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-842s_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BDCB1321-793F-455C-847C-E5033A920F1F",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-842s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "996A7C60-49BB-46BE-8A2C-CEABA71FBEB3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-815s_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F2A35FF-2623-4D3C-920A-42B836984085",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-815s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C6BA467-0AB4-42BF-BBD1-59E2FA03CF42",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dsl-2640u_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C0D3126B-FE49-4C78-A734-95C3C0276AE2",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dsl-2640u:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "09E483F8-5B0E-498A-B1CA-8F1EA5FD350C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-2150_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A3A04F04-D2DC-4DC9-B44B-F5DEC933E9AC",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-2150:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "06F065A1-2599-442C-AB55-DE24D47A7869",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dwr-921_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A61E0E68-F20D-4663-9855-B71F60266B83",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dwr-921:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "43F0390E-B9E1-463A-A08C-B529778EE72F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-615s_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9FE9B1C-6246-458F-AF0D-E624D1DBFAE2",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-615s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A74ABB9E-FD49-431A-BB23-9DCA44B8A806",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-620_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F098AF6-DC38-4D50-9316-809349CB573E",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-620:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1DF4C296-C8AA-4197-B280-ED5D22C70156",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dvg-5402g_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D27F65EC-6C50-4691-99A2-EA1C1D3DE0C8",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dvg-5402g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F1C2C7F0-FE1C-4B95-9636-FA6041C85C44",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-882_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A2472D8A-C45A-447B-A296-B2BB93A7E948",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-882:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F6ECB8ED-F3A2-4C05-8570-719ECB166B09",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dwm-312w_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B065B35-4FC9-4D4C-823D-F06418454CC9",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dwm-312w:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F03A354-6EBE-4081-9234-00DCB747EAB5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-815\\/ac_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A78E427F-121A-4453-B0BD-48C2A516FE5A",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-815\\/ac:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "291ACFCF-032B-466D-9C5B-D5CCF9CA7DD9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dsl-224_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "500B6A19-ED9A-404C-A071-D77F4263288F",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dsl-224:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5C744969-0177-4E24-8E60-1DB0EFE1E5C5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dwm-321_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "29D9E5D9-B9E8-4BD0-B6DC-F253559925B3",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dwm-321:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "66BD8659-B935-441C-9AFF-20E8AE157E2B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-x1860_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E3BFEE9-5E48-4D94-977B-7A79CF2AEB1A",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-x1860:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A46288E8-3105-4FAA-80E7-94EECD1764F2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dap-1360_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D83F75D8-3563-4A07-A794-6970A63EAA9B",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dap-1360:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6E95864-1D6F-4BB2-9940-144385527271",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-820_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D1790403-AC76-4A3E-B727-836AF7ABCF10",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-820:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C30FD50-1AC6-476A-85B9-30D24E0663DC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-843_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7B29BE39-F488-4C74-8B5C-F8D6C3256F96",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-843:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "85293557-FC2C-4A56-8EA0-6E12968E7FBF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dvg-5402g\\/gfru_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "672ADB90-0062-48CE-B437-28919980A4B0",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dvg-5402g\\/gfru:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B4C4C431-489D-4F09-A312-B4FBCC38E91E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dwr-953_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8AA2FBAD-C15D-4908-AB8B-23087354D4A8",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dwr-953:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E37EEA4D-B3F6-4A39-971C-07C1CB0BA209",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dvg-n5402g\\/il_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "236D3547-1FB9-44B3-ABD2-F948912B6D4D",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dvg-n5402g\\/il:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B118E9B4-961D-46B6-95E3-514A99C8BFA8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-825ac_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "065F9B59-FBA8-4798-8F29-82741815B0CD",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-825ac:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7C8BB581-D7A3-494A-AB43-BCAE390ED692",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-620s_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC3409D3-C046-410B-96BB-128FC1C2C097",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-620s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9932A023-1CE6-4915-812D-F3CE5EAB114C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dvg-n5402g_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5AEE17B3-F77C-4F3A-92D7-99BFF1F1A824",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dvg-n5402g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1127DA2D-4024-4962-B8FB-C81E07B1AE94",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dsl-2750u_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B0191F0-DB03-479F-BA89-8CBF6F378BD6",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dsl-2750u:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5A7A48A-C126-4EF2-91F8-A8D9987525FF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-615gf_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "43227AC8-29BA-43E9-AB4F-10C83F222514",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-615gf:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9199BBF6-42E4-418E-8A3C-7F69CCB3D145",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-816_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "876FA028-A6B1-488A-A29D-038D93539C07",
              "versionEndIncluding": "2024-01-12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-816:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B54058C1-B58F-434A-ABF0-A6B314A1AB14",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability classified as critical was found in D-Link DAP-1360, DIR-300, DIR-615, DIR-615GF, DIR-615S, DIR-615T, DIR-620, DIR-620S, DIR-806A, DIR-815, DIR-815AC, DIR-815S, DIR-816, DIR-820, DIR-822, DIR-825, DIR-825AC, DIR-825ACF, DIR-825ACG1, DIR-841, DIR-842, DIR-842S, DIR-843, DIR-853, DIR-878, DIR-882, DIR-1210, DIR-1260, DIR-2150, DIR-X1530, DIR-X1860, DSL-224, DSL-245GR, DSL-2640U, DSL-2750U, DSL-G2452GR, DVG-5402G, DVG-5402G, DVG-5402GFRU, DVG-N5402G, DVG-N5402G-IL, DWM-312W, DWM-321, DWR-921, DWR-953 and Good Line Router v2 up to 20240112. This vulnerability affects unknown code of the file /devinfo of the component HTTP GET Request Handler. The manipulation of the argument area with the input notice|net|version leads to information disclosure. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-251542 is the identifier assigned to this vulnerability."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad fue encontrada en D-Link DAP-1360, DIR-300, DIR-615, DIR-615GF, DIR-615S, DIR-615T, DIR-620, DIR-620S, DIR-806A, DIR-815 y clasificada como cr\u00edtica , DIR-815AC, DIR-815S, DIR-816, DIR-820, DIR-822, DIR-825, DIR-825AC, DIR-825ACF, DIR-825ACG1, DIR-841, DIR-842, DIR-842S, DIR -843, DIR-853, DIR-878, DIR-882, DIR-1210, DIR-1260, DIR-2150, DIR-X1530, DIR-X1860, DSL-224, DSL-245GR, DSL-2640U, DSL-2750U , DSL-G2452GR, DVG-5402G, DVG-5402G, DVG-5402GFRU, DVG-N5402G, DVG-N5402G-IL, DWM-312W, DWM-321, DWR-921, DWR-953 y Good Line Router v2 hasta 20240112 Esta vulnerabilidad afecta a c\u00f3digo desconocido del archivo /devinfo del componente HTTP GET Request Handler. La manipulaci\u00f3n del \u00e1rea de argumentos con la entrada aviso|net|versi\u00f3n conduce a la divulgaci\u00f3n de informaci\u00f3n. El ataque se puede iniciar de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. VDB-251542 es el identificador asignado a esta vulnerabilidad."
    }
  ],
  "id": "CVE-2024-0717",
  "lastModified": "2024-11-21T08:47:12.370",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "cna@vuldb.com",
        "type": "Secondary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 1.4,
        "source": "cna@vuldb.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 1.4,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-01-19T16:15:11.190",
  "references": [
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/999zzzzz/D-Link"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://vuldb.com/?ctiid.251542"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://vuldb.com/?id.251542"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/999zzzzz/D-Link"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://vuldb.com/?ctiid.251542"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://vuldb.com/?id.251542"
    }
  ],
  "sourceIdentifier": "cna@vuldb.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-200"
        }
      ],
      "source": "cna@vuldb.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-05-23 01:15
Modified
2025-01-17 18:15
Summary
D-Link DIR-300 firmware <=REVA1.06 and <=REVB2.06 is vulnerable to File inclusion via /model/__lang_msg.php.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-300_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "58317720-E35D-4B04-9ED8-20F9891C201B",
              "versionEndIncluding": "1.06",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-300:a:*:*:*:*:*:*:*",
              "matchCriteriaId": "EDA56E33-B2C7-4D57-B70A-D1ED9FEDB644",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-300_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "022C9ACD-5E0C-412D-8F3D-DC444FF1EDFA",
              "versionEndIncluding": "2.06",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-300:b:*:*:*:*:*:*:*",
              "matchCriteriaId": "3C94BE4B-01ED-4300-AEA0-498D3DCF608D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "D-Link DIR-300 firmware \u003c=REVA1.06 and \u003c=REVB2.06 is vulnerable to File inclusion via /model/__lang_msg.php."
    }
  ],
  "id": "CVE-2023-31814",
  "lastModified": "2025-01-17T18:15:23.030",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2023-05-23T01:15:10.087",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://gist.github.com/1915504804/9503198d3cbd5bc7db47625ac0caaade"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Product"
      ],
      "url": "https://www.dlink.com/en/security-bulletin/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://gist.github.com/1915504804/9503198d3cbd5bc7db47625ac0caaade"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Product"
      ],
      "url": "https://www.dlink.com/en/security-bulletin/"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-706"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-08-06 16:15
Modified
2024-08-07 20:54
Summary
D-Link DIR-300 REVA FIRMWARE v1.06B05_WW contains hardcoded credentials in the Telnet service.
Impacted products
Vendor Product Version
dlink dir-300_firmware 1.06b05_ww
dlink dir-300 a



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-300_firmware:1.06b05_ww:*:*:*:*:*:*:*",
              "matchCriteriaId": "36A2AF0E-E92C-49FA-B98B-615956616275",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-300:a:*:*:*:*:*:*:*",
              "matchCriteriaId": "EDA56E33-B2C7-4D57-B70A-D1ED9FEDB644",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "D-Link DIR-300 REVA FIRMWARE v1.06B05_WW contains hardcoded credentials in the Telnet service."
    },
    {
      "lang": "es",
      "value": "D-Link DIR-300 REVA FIRMWARE v1.06B05_WW contiene credenciales codificadas en el servicio Telnet."
    }
  ],
  "id": "CVE-2024-41616",
  "lastModified": "2024-08-07T20:54:20.793",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-08-06T16:15:49.260",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://github.com/LYaoBoL/IOTsec/blob/main/D-Link/DIR300/CVE-2024-41616"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/LYaoBoL/IOTsec/blob/main/D-Link/DIR300/D-Link300.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-798"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-259"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2019-06-11 21:29
Modified
2024-11-21 02:01
Severity ?
Summary
An issue was discovered in soap.cgi?service=WANIPConn1 on D-Link DIR-845 before v1.02b03, DIR-600 before v2.17b01, DIR-645 before v1.04b11, DIR-300 rev. B, and DIR-865 devices. There is Command Injection via shell metacharacters in the NewInternalClient, NewExternalPort, or NewInternalPort element of a SOAP POST request.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-300_firmware:2.14b01:*:*:*:*:*:*:*",
              "matchCriteriaId": "3FA53054-8F21-497B-B220-CB77F0F997C7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-300:b:*:*:*:*:*:*:*",
              "matchCriteriaId": "3C94BE4B-01ED-4300-AEA0-498D3DCF608D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-600_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "81DD6B48-FCE3-4220-8677-69665DE92A6E",
              "versionEndExcluding": "2.17b01",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A7A8637C-BD16-4B96-A1DA-34529F3169D3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-645_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "57B7E296-D25F-4991-ABE9-4FA07846ED3D",
              "versionEndExcluding": "1.04b11",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-645:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7D49F68-E15D-478B-B88E-089291BF7DB6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-845_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "ACEC2324-0103-45B1-A874-1FA3AC9C3CA4",
              "versionEndExcluding": "1.02b03",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-845:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F89A1489-4ACD-4140-A130-12CD7409437A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-865_firmware:1.05b03:*:*:*:*:*:*:*",
              "matchCriteriaId": "C69C3448-3D2C-4FF8-80C5-AB73B0AFD39D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-865:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1DE230FF-F0FD-42F2-BBFB-CD2B9DD5EA1D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered in soap.cgi?service=WANIPConn1 on D-Link DIR-845 before v1.02b03, DIR-600 before v2.17b01, DIR-645 before v1.04b11, DIR-300 rev. B, and DIR-865 devices. There is Command Injection via shell metacharacters in the NewInternalClient, NewExternalPort, or NewInternalPort element of a SOAP POST request."
    },
    {
      "lang": "es",
      "value": "Se descubri\u00f3 un problema en soap.cgi? Service = WANIPConn1 en D-Link DIR-845 anterior de v1.02b03, DIR-600 antes de v2.17b01, DIR-645 anterior de v1.04b11, DIR-300 rev. B, y dispositivos DIR-865. Existe una Inyecci\u00f3n de comandos a trav\u00e9s de metacaracteres de shell en el elemento NewInternalClient, NewExternalPort o NewInternalPort de una solicitud POST de SOAP."
    }
  ],
  "id": "CVE-2013-7471",
  "lastModified": "2024-11-21T02:01:05.363",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-06-11T21:29:00.397",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "http://www.s3cur1ty.de/m1adv2013-020"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.exploit-db.com/exploits/27044"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "http://www.s3cur1ty.de/m1adv2013-020"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.exploit-db.com/exploits/27044"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2011-12-20 11:55
Modified
2025-02-10 20:15
Summary
The D-Link DIR-300 router stores cleartext passwords, which allows context-dependent attackers to obtain sensitive information via unspecified vectors.
Impacted products
Vendor Product Version
dlink dir-300 *



{
  "cisaActionDue": "2022-09-29",
  "cisaExploitAdd": "2022-09-08",
  "cisaRequiredAction": "The impacted product is end-of-life and should be disconnected if still in use.",
  "cisaVulnerabilityName": "D-Link DIR-300 Router Cleartext Storage of a Password Vulnerability",
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-300:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "46716C2A-12B7-414A-A1A2-CB49FCBDE8AE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "The D-Link DIR-300 router stores cleartext passwords, which allows context-dependent attackers to obtain sensitive information via unspecified vectors."
    },
    {
      "lang": "es",
      "value": "El router D-Link DIR-300 almacena contrase\u00f1as en texto plano, lo que permite a atacantes locales o remotos obtener informaci\u00f3n sensible a trav\u00e9s de vectores desconocidos."
    }
  ],
  "id": "CVE-2011-4723",
  "lastModified": "2025-02-10T20:15:32.090",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "NONE",
          "baseScore": 6.8,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:S/C:C/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.7,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.1,
        "impactScore": 3.6,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2011-12-20T11:55:08.413",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Broken Link"
      ],
      "url": "http://en.securitylab.ru/lab/PT-2011-30"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Broken Link"
      ],
      "url": "http://en.securitylab.ru/lab/PT-2011-30"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-310"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-312"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

cve-2024-0717
Vulnerability from cvelistv5
Published
2024-01-19 15:31
Modified
2024-08-01 18:11
Summary
A vulnerability classified as critical was found in D-Link DAP-1360, DIR-300, DIR-615, DIR-615GF, DIR-615S, DIR-615T, DIR-620, DIR-620S, DIR-806A, DIR-815, DIR-815AC, DIR-815S, DIR-816, DIR-820, DIR-822, DIR-825, DIR-825AC, DIR-825ACF, DIR-825ACG1, DIR-841, DIR-842, DIR-842S, DIR-843, DIR-853, DIR-878, DIR-882, DIR-1210, DIR-1260, DIR-2150, DIR-X1530, DIR-X1860, DSL-224, DSL-245GR, DSL-2640U, DSL-2750U, DSL-G2452GR, DVG-5402G, DVG-5402G, DVG-5402GFRU, DVG-N5402G, DVG-N5402G-IL, DWM-312W, DWM-321, DWR-921, DWR-953 and Good Line Router v2 up to 20240112. This vulnerability affects unknown code of the file /devinfo of the component HTTP GET Request Handler. The manipulation of the argument area with the input notice|net|version leads to information disclosure. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-251542 is the identifier assigned to this vulnerability.
References
https://vuldb.com/?id.251542vdb-entry, technical-description
https://vuldb.com/?ctiid.251542signature, permissions-required
https://github.com/999zzzzz/D-Linkexploit
Impacted products
Vendor Product Version
D-Link DAP-1360 Version: 20240112
Create a notification for this product.
   D-Link DIR-300 Version: 20240112
Create a notification for this product.
   D-Link DIR-615 Version: 20240112
Create a notification for this product.
   D-Link DIR-615GF Version: 20240112
Create a notification for this product.
   D-Link DIR-615S Version: 20240112
Create a notification for this product.
   D-Link DIR-615T Version: 20240112
Create a notification for this product.
   D-Link DIR-620 Version: 20240112
Create a notification for this product.
   D-Link DIR-620S Version: 20240112
Create a notification for this product.
   D-Link DIR-806A Version: 20240112
Create a notification for this product.
   D-Link DIR-815 Version: 20240112
Create a notification for this product.
   D-Link DIR-815AC Version: 20240112
Create a notification for this product.
   D-Link DIR-815S Version: 20240112
Create a notification for this product.
   D-Link DIR-816 Version: 20240112
Create a notification for this product.
   D-Link DIR-820 Version: 20240112
Create a notification for this product.
   D-Link DIR-822 Version: 20240112
Create a notification for this product.
   D-Link DIR-825 Version: 20240112
Create a notification for this product.
   D-Link DIR-825AC Version: 20240112
Create a notification for this product.
   D-Link DIR-825ACF Version: 20240112
Create a notification for this product.
   D-Link DIR-825ACG1 Version: 20240112
Create a notification for this product.
   D-Link DIR-841 Version: 20240112
Create a notification for this product.
   D-Link DIR-842 Version: 20240112
Create a notification for this product.
   D-Link DIR-842S Version: 20240112
Create a notification for this product.
   D-Link DIR-843 Version: 20240112
Create a notification for this product.
   D-Link DIR-853 Version: 20240112
Create a notification for this product.
   D-Link DIR-878 Version: 20240112
Create a notification for this product.
   D-Link DIR-882 Version: 20240112
Create a notification for this product.
   D-Link DIR-1210 Version: 20240112
Create a notification for this product.
   D-Link DIR-1260 Version: 20240112
Create a notification for this product.
   D-Link DIR-2150 Version: 20240112
Create a notification for this product.
   D-Link DIR-X1530 Version: 20240112
Create a notification for this product.
   D-Link DIR-X1860 Version: 20240112
Create a notification for this product.
   D-Link DSL-224 Version: 20240112
Create a notification for this product.
   D-Link DSL-245GR Version: 20240112
Create a notification for this product.
   D-Link DSL-2640U Version: 20240112
Create a notification for this product.
   D-Link DSL-2750U Version: 20240112
Create a notification for this product.
   D-Link DSL-G2452GR Version: 20240112
Create a notification for this product.
   D-Link DVG-5402G Version: 20240112
Create a notification for this product.
   D-Link DVG-5402G Version: 20240112
Create a notification for this product.
   D-Link DVG-5402GFRU Version: 20240112
Create a notification for this product.
   D-Link DVG-N5402G Version: 20240112
Create a notification for this product.
   D-Link DVG-N5402G-IL Version: 20240112
Create a notification for this product.
   D-Link DWM-312W Version: 20240112
Create a notification for this product.
   D-Link DWM-321 Version: 20240112
Create a notification for this product.
   D-Link DWR-921 Version: 20240112
Create a notification for this product.
   D-Link DWR-953 Version: 20240112
Create a notification for this product.
   D-Link Good Line Router v2 Version: 20240112
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T18:11:35.784Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.251542"
          },
          {
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.251542"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/999zzzzz/D-Link"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DAP-1360",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DIR-300",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DIR-615",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DIR-615GF",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DIR-615S",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DIR-615T",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DIR-620",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DIR-620S",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DIR-806A",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DIR-815",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DIR-815AC",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DIR-815S",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DIR-816",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DIR-820",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DIR-822",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DIR-825",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DIR-825AC",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DIR-825ACF",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DIR-825ACG1",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DIR-841",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DIR-842",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DIR-842S",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DIR-843",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DIR-853",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DIR-878",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DIR-882",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DIR-1210",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DIR-1260",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DIR-2150",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DIR-X1530",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DIR-X1860",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DSL-224",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DSL-245GR",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DSL-2640U",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DSL-2750U",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DSL-G2452GR",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DVG-5402G",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DVG-5402G",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DVG-5402GFRU",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DVG-N5402G",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DVG-N5402G-IL",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DWM-312W",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DWM-321",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DWR-921",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "DWR-953",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        },
        {
          "modules": [
            "HTTP GET Request Handler"
          ],
          "product": "Good Line Router v2",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20240112"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "99iz (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical was found in D-Link DAP-1360, DIR-300, DIR-615, DIR-615GF, DIR-615S, DIR-615T, DIR-620, DIR-620S, DIR-806A, DIR-815, DIR-815AC, DIR-815S, DIR-816, DIR-820, DIR-822, DIR-825, DIR-825AC, DIR-825ACF, DIR-825ACG1, DIR-841, DIR-842, DIR-842S, DIR-843, DIR-853, DIR-878, DIR-882, DIR-1210, DIR-1260, DIR-2150, DIR-X1530, DIR-X1860, DSL-224, DSL-245GR, DSL-2640U, DSL-2750U, DSL-G2452GR, DVG-5402G, DVG-5402G, DVG-5402GFRU, DVG-N5402G, DVG-N5402G-IL, DWM-312W, DWM-321, DWR-921, DWR-953 and Good Line Router v2 up to 20240112. This vulnerability affects unknown code of the file /devinfo of the component HTTP GET Request Handler. The manipulation of the argument area with the input notice|net|version leads to information disclosure. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-251542 is the identifier assigned to this vulnerability."
        },
        {
          "lang": "de",
          "value": "In D-Link DAP-1360, DIR-300, DIR-615, DIR-615GF, DIR-615S, DIR-615T, DIR-620, DIR-620S, DIR-806A, DIR-815, DIR-815AC, DIR-815S, DIR-816, DIR-820, DIR-822, DIR-825, DIR-825AC, DIR-825ACF, DIR-825ACG1, DIR-841, DIR-842, DIR-842S, DIR-843, DIR-853, DIR-878, DIR-882, DIR-1210, DIR-1260, DIR-2150, DIR-X1530, DIR-X1860, DSL-224, DSL-245GR, DSL-2640U, DSL-2750U, DSL-G2452GR, DVG-5402G, DVG-5402G, DVG-5402GFRU, DVG-N5402G, DVG-N5402G-IL, DWM-312W, DWM-321, DWR-921, DWR-953 and Good Line Router v2 bis 20240112 wurde eine Schwachstelle entdeckt. Sie wurde als kritisch eingestuft. Betroffen ist eine unbekannte Verarbeitung der Datei /devinfo der Komponente HTTP GET Request Handler. Mittels dem Manipulieren des Arguments area mit der Eingabe notice|net|version mit unbekannten Daten kann eine information disclosure-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 5,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200 Information Disclosure",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-01-19T15:31:04.290Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.251542"
        },
        {
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.251542"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/999zzzzz/D-Link"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-01-19T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-01-19T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-01-19T08:26:48.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "D-Link Good Line Router v2 HTTP GET Request devinfo information disclosure"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-0717",
    "datePublished": "2024-01-19T15:31:04.290Z",
    "dateReserved": "2024-01-19T07:21:32.386Z",
    "dateUpdated": "2024-08-01T18:11:35.784Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2011-4723
Vulnerability from cvelistv5
Published
2011-12-20 11:00
Modified
2025-02-10 20:01
Summary
The D-Link DIR-300 router stores cleartext passwords, which allows context-dependent attackers to obtain sensitive information via unspecified vectors.
References
http://en.securitylab.ru/lab/PT-2011-30x_refsource_MISC
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-07T00:16:34.283Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://en.securitylab.ru/lab/PT-2011-30"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.7,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2011-4723",
                "options": [
                  {
                    "Exploitation": "active"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-10T20:01:02.727626Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          },
          {
            "other": {
              "content": {
                "dateAdded": "2022-09-08",
                "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?search_api_fulltext=CVE-2011-4723"
              },
              "type": "kev"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-312",
                "description": "CWE-312 Cleartext Storage of Sensitive Information",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-10T20:01:06.236Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The D-Link DIR-300 router stores cleartext passwords, which allows context-dependent attackers to obtain sensitive information via unspecified vectors."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2011-12-20T11:00:00.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://en.securitylab.ru/lab/PT-2011-30"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2011-4723",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The D-Link DIR-300 router stores cleartext passwords, which allows context-dependent attackers to obtain sensitive information via unspecified vectors."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://en.securitylab.ru/lab/PT-2011-30",
              "refsource": "MISC",
              "url": "http://en.securitylab.ru/lab/PT-2011-30"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2011-4723",
    "datePublished": "2011-12-20T11:00:00.000Z",
    "dateReserved": "2011-12-10T00:00:00.000Z",
    "dateUpdated": "2025-02-10T20:01:06.236Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-41616
Vulnerability from cvelistv5
Published
2024-08-06 00:00
Modified
2024-08-06 15:58
Summary
D-Link DIR-300 REVA FIRMWARE v1.06B05_WW contains hardcoded credentials in the Telnet service.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:dlink:dir-300_firmware:1.06b05_ww:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "dir-300_firmware",
            "vendor": "dlink",
            "versions": [
              {
                "status": "affected",
                "version": "1.06b05_ww"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-41616",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-06T15:57:56.089354Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-259",
                "description": "CWE-259 Use of Hard-coded Password",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-06T15:58:09.126Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "D-Link DIR-300 REVA FIRMWARE v1.06B05_WW contains hardcoded credentials in the Telnet service."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-06T15:14:56.300385",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/LYaoBoL/IOTsec/blob/main/D-Link/DIR300/D-Link300.md"
        },
        {
          "url": "https://github.com/LYaoBoL/IOTsec/blob/main/D-Link/DIR300/CVE-2024-41616"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-41616",
    "datePublished": "2024-08-06T00:00:00",
    "dateReserved": "2024-07-18T00:00:00",
    "dateUpdated": "2024-08-06T15:58:09.126Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-31814
Vulnerability from cvelistv5
Published
2023-05-23 00:00
Modified
2025-01-17 17:53
Severity ?
Summary
D-Link DIR-300 firmware <=REVA1.06 and <=REVB2.06 is vulnerable to File inclusion via /model/__lang_msg.php.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:56:35.595Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.dlink.com/en/security-bulletin/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://gist.github.com/1915504804/9503198d3cbd5bc7db47625ac0caaade"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2023-31814",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-17T17:49:11.316527Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-706",
                "description": "CWE-706 Use of Incorrectly-Resolved Name or Reference",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-17T17:53:54.721Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "D-Link DIR-300 firmware \u003c=REVA1.06 and \u003c=REVB2.06 is vulnerable to File inclusion via /model/__lang_msg.php."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-23T00:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.dlink.com/en/security-bulletin/"
        },
        {
          "url": "https://gist.github.com/1915504804/9503198d3cbd5bc7db47625ac0caaade"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-31814",
    "datePublished": "2023-05-23T00:00:00",
    "dateReserved": "2023-04-29T00:00:00",
    "dateUpdated": "2025-01-17T17:53:54.721Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2013-7471
Vulnerability from cvelistv5
Published
2019-06-11 20:46
Modified
2024-08-06 18:09
Severity ?
Summary
An issue was discovered in soap.cgi?service=WANIPConn1 on D-Link DIR-845 before v1.02b03, DIR-600 before v2.17b01, DIR-645 before v1.04b11, DIR-300 rev. B, and DIR-865 devices. There is Command Injection via shell metacharacters in the NewInternalClient, NewExternalPort, or NewInternalPort element of a SOAP POST request.
References
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T18:09:16.715Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.s3cur1ty.de/m1adv2013-020"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.exploit-db.com/exploits/27044"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in soap.cgi?service=WANIPConn1 on D-Link DIR-845 before v1.02b03, DIR-600 before v2.17b01, DIR-645 before v1.04b11, DIR-300 rev. B, and DIR-865 devices. There is Command Injection via shell metacharacters in the NewInternalClient, NewExternalPort, or NewInternalPort element of a SOAP POST request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-06-11T20:46:45",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.s3cur1ty.de/m1adv2013-020"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.exploit-db.com/exploits/27044"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2013-7471",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered in soap.cgi?service=WANIPConn1 on D-Link DIR-845 before v1.02b03, DIR-600 before v2.17b01, DIR-645 before v1.04b11, DIR-300 rev. B, and DIR-865 devices. There is Command Injection via shell metacharacters in the NewInternalClient, NewExternalPort, or NewInternalPort element of a SOAP POST request."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.s3cur1ty.de/m1adv2013-020",
              "refsource": "MISC",
              "url": "http://www.s3cur1ty.de/m1adv2013-020"
            },
            {
              "name": "https://www.exploit-db.com/exploits/27044",
              "refsource": "MISC",
              "url": "https://www.exploit-db.com/exploits/27044"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2013-7471",
    "datePublished": "2019-06-11T20:46:45",
    "dateReserved": "2019-06-11T00:00:00",
    "dateUpdated": "2024-08-06T18:09:16.715Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}