Vulnerabilites related to crestron - dge-100_firmware
Vulnerability from fkie_nvd
Published
2018-07-10 16:29
Modified
2024-11-21 04:09
Summary
The Crestron Console service running on DGE-100, DM-DGE-200-C, and TS-1542-C devices with default configuration and running firmware versions 1.3384.00049.001 and lower are vulnerable to command injection that can be used to gain root-level access.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:crestron:dge-100_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2F48676D-D566-45C5-965B-B20ED8F2817F",
              "versionEndIncluding": "1.3384.00049.001",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:crestron:dge-100:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5D6A6E8-4FF6-467F-8F59-5512DD5B0A2C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:crestron:dm-dge-200-c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D0D4D4C-9AE5-4500-8531-691E766A3175",
              "versionEndIncluding": "1.3384.00049.001",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:crestron:dm-dge-200-c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D0D4FFAC-0D1F-4D58-986B-3F402EE643AE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:crestron:ts-1542-c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8D4AA22E-4175-4B81-BC75-B88868785FD5",
              "versionEndIncluding": "1.3384.00049.001",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:crestron:ts-1542-c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B59A47EB-692A-47A0-B1CE-6967A18B7A37",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "The Crestron Console service running on DGE-100, DM-DGE-200-C, and TS-1542-C devices with default configuration and running firmware versions 1.3384.00049.001 and lower are vulnerable to command injection that can be used to gain root-level access."
    },
    {
      "lang": "es",
      "value": "El servicio Crestron Console en los dispositivos DGE-100, DM-DGE-200-C y TS-1542-C con la configuraci\u00f3n por defecto y ejecutando versiones del firmware 1.3384.00049.001 y anteriores es vulnerable a una inyecci\u00f3n de comandos que puede emplearse para obtener acceso a nivel root."
    }
  ],
  "id": "CVE-2018-5553",
  "lastModified": "2024-11-21T04:09:03.720",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "cve@rapid7.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-07-10T16:29:00.970",
  "references": [
    {
      "source": "cve@rapid7.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://blog.rapid7.com/2018/06/12/r7-2018-15-cve-2018-5553-crestron-dge-100-console-command-injection-fixed/"
    },
    {
      "source": "cve@rapid7.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet#CVE%C2%AD-2018%C2%AD-5553"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://blog.rapid7.com/2018/06/12/r7-2018-15-cve-2018-5553-crestron-dge-100-console-command-injection-fixed/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet#CVE%C2%AD-2018%C2%AD-5553"
    }
  ],
  "sourceIdentifier": "cve@rapid7.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ],
      "source": "cve@rapid7.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

cve-2018-5553
Vulnerability from cvelistv5
Published
2018-07-10 16:00
Modified
2024-09-16 22:20
Severity ?
Summary
The Crestron Console service running on DGE-100, DM-DGE-200-C, and TS-1542-C devices with default configuration and running firmware versions 1.3384.00049.001 and lower are vulnerable to command injection that can be used to gain root-level access.
Impacted products
Vendor Product Version
Crestron DGE-100 Version: unspecified   <
Create a notification for this product.
   Crestron TS-1542-C Version: unspecified   <
Create a notification for this product.
   Crestron DM-DGE-200-C Version: unspecified   <
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T05:40:50.678Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet#CVE%C2%AD-2018%C2%AD-5553"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://blog.rapid7.com/2018/06/12/r7-2018-15-cve-2018-5553-crestron-dge-100-console-command-injection-fixed/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DGE-100",
          "vendor": "Crestron",
          "versions": [
            {
              "lessThanOrEqual": "1.3384.00049.001",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "TS-1542-C",
          "vendor": "Crestron",
          "versions": [
            {
              "lessThanOrEqual": "1.3384.00049.001",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "DM-DGE-200-C",
          "vendor": "Crestron",
          "versions": [
            {
              "lessThanOrEqual": "1.3384.00049.001",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "This issue was discovered by Rapid7 researchers Cale Black and Jordan Larose. It is being disclosed in accordance Rapid7\u0027s vulnerability disclosure policy (https://www.rapid7.com/disclosure/)."
        }
      ],
      "datePublic": "2018-06-12T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "The Crestron Console service running on DGE-100, DM-DGE-200-C, and TS-1542-C devices with default configuration and running firmware versions 1.3384.00049.001 and lower are vulnerable to command injection that can be used to gain root-level access."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 (Improper Neutralization of Special Elements used in an OS Command)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-07-10T15:57:01",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet#CVE%C2%AD-2018%C2%AD-5553"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://blog.rapid7.com/2018/06/12/r7-2018-15-cve-2018-5553-crestron-dge-100-console-command-injection-fixed/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Users should update affected devices to the latest firmware version (1.3384.00059.001 or higher) available from Crestron\u0027s product pages."
        }
      ],
      "source": {
        "advisory": "R7-2018-15",
        "discovery": "EXTERNAL"
      },
      "title": "Crestron DGE-100 Console Command Injection (FIXED)",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "AKA": "",
          "ASSIGNER": "cve@rapid7.com",
          "DATE_PUBLIC": "2018-06-12T10:00:00.000Z",
          "ID": "CVE-2018-5553",
          "STATE": "PUBLIC",
          "TITLE": "Crestron DGE-100 Console Command Injection (FIXED)"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "DGE-100",
                      "version": {
                        "version_data": [
                          {
                            "affected": "\u003c=",
                            "platform": "",
                            "version_affected": "\u003c=",
                            "version_name": "",
                            "version_value": "1.3384.00049.001"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TS-1542-C",
                      "version": {
                        "version_data": [
                          {
                            "affected": "\u003c=",
                            "platform": "",
                            "version_affected": "\u003c=",
                            "version_name": "",
                            "version_value": "1.3384.00049.001"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "DM-DGE-200-C",
                      "version": {
                        "version_data": [
                          {
                            "affected": "\u003c=",
                            "platform": "",
                            "version_affected": "\u003c=",
                            "version_name": "",
                            "version_value": "1.3384.00049.001"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Crestron"
              }
            ]
          }
        },
        "configuration": [],
        "credit": [
          {
            "lang": "eng",
            "value": "This issue was discovered by Rapid7 researchers Cale Black and Jordan Larose. It is being disclosed in accordance Rapid7\u0027s vulnerability disclosure policy (https://www.rapid7.com/disclosure/)."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The Crestron Console service running on DGE-100, DM-DGE-200-C, and TS-1542-C devices with default configuration and running firmware versions 1.3384.00049.001 and lower are vulnerable to command injection that can be used to gain root-level access."
            }
          ]
        },
        "exploit": [],
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-78 (Improper Neutralization of Special Elements used in an OS Command)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet#CVE%C2%AD-2018%C2%AD-5553",
              "refsource": "CONFIRM",
              "url": "https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet#CVE%C2%AD-2018%C2%AD-5553"
            },
            {
              "name": "https://blog.rapid7.com/2018/06/12/r7-2018-15-cve-2018-5553-crestron-dge-100-console-command-injection-fixed/",
              "refsource": "MISC",
              "url": "https://blog.rapid7.com/2018/06/12/r7-2018-15-cve-2018-5553-crestron-dge-100-console-command-injection-fixed/"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Users should update affected devices to the latest firmware version (1.3384.00059.001 or higher) available from Crestron\u0027s product pages."
          }
        ],
        "source": {
          "advisory": "R7-2018-15",
          "defect": [],
          "discovery": "EXTERNAL"
        },
        "work_around": []
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2018-5553",
    "datePublished": "2018-07-10T16:00:00Z",
    "dateReserved": "2018-01-12T00:00:00",
    "dateUpdated": "2024-09-16T22:20:46.752Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}