Vulnerabilites related to dlink - dar-8000-10_firmware
cve-2023-4542
Vulnerability from cvelistv5
Published
2023-08-25 21:31
Modified
2024-08-02 07:31
Severity ?
6.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
6.3 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
6.3 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
EPSS score ?
Summary
A vulnerability was found in D-Link DAR-8000-10 up to 20230809. It has been classified as critical. This affects an unknown part of the file /app/sys1.php. The manipulation of the argument cmd with the input id leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-238047. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.238047 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.238047 | signature, permissions-required | |
https://github.com/PumpkinBridge/cve/blob/main/rce.md | exploit |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
D-Link | DAR-8000-10 |
Version: 20230809 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T07:31:06.464Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.238047" }, { "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.238047" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/PumpkinBridge/cve/blob/main/rce.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "DAR-8000-10", "vendor": "D-Link", "versions": [ { "status": "affected", "version": "20230809" } ] } ], "credits": [ { "lang": "en", "type": "analyst", "value": "PumkinBridge (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in D-Link DAR-8000-10 up to 20230809. It has been classified as critical. This affects an unknown part of the file /app/sys1.php. The manipulation of the argument cmd with the input id leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-238047. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Es wurde eine Schwachstelle in D-Link DAR-8000-10 bis 20230809 ausgemacht. Sie wurde als kritisch eingestuft. Es geht dabei um eine nicht klar definierte Funktion der Datei /app/sys1.php. Durch das Manipulieren des Arguments cmd mit der Eingabe id mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 6.5, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 OS Command Injection", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-10-24T14:48:55.188Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.238047" }, { "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.238047" }, { "tags": [ "exploit" ], "url": "https://github.com/PumpkinBridge/cve/blob/main/rce.md" } ], "timeline": [ { "lang": "en", "time": "2023-08-25T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2023-08-25T00:00:00.000Z", "value": "CVE reserved" }, { "lang": "en", "time": "2023-08-25T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2023-09-20T12:46:37.000Z", "value": "VulDB entry last update" } ], "title": "D-Link DAR-8000-10 sys1.php os command injection" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2023-4542", "datePublished": "2023-08-25T21:31:04.605Z", "dateReserved": "2023-08-25T15:18:48.598Z", "dateUpdated": "2024-08-02T07:31:06.464Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-4711
Vulnerability from cvelistv5
Published
2023-09-01 19:00
Modified
2024-08-02 07:37
Severity ?
5.0 (Medium) - CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:L/I:L/A:L
5.0 (Medium) - CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:U/C:L/I:L/A:L
5.0 (Medium) - CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:U/C:L/I:L/A:L
EPSS score ?
Summary
A vulnerability, which was classified as critical, has been found in D-Link DAR-8000-10 up to 20230819. Affected by this issue is some unknown functionality of the file /log/decodmail.php. The manipulation of the argument file leads to os command injection. The attack may be launched remotely. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. VDB-238574 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.238574 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.238574 | signature, permissions-required | |
https://github.com/TinkAnet/cve/blob/main/rce.md | exploit |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
D-Link | DAR-8000-10 |
Version: 20230819 |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:dlink:dar-8000-10_firmware:20230819:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "dar-8000-10_firmware", "vendor": "dlink", "versions": [ { "status": "affected", "version": "20230819" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-4711", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-06-05T20:30:11.927778Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-05T20:30:42.638Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-02T07:37:59.572Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.238574" }, { "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.238574" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/TinkAnet/cve/blob/main/rce.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "DAR-8000-10", "vendor": "D-Link", "versions": [ { "status": "affected", "version": "20230819" } ] } ], "credits": [ { "lang": "en", "type": "analyst", "value": "Tinkanet (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, has been found in D-Link DAR-8000-10 up to 20230819. Affected by this issue is some unknown functionality of the file /log/decodmail.php. The manipulation of the argument file leads to os command injection. The attack may be launched remotely. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. VDB-238574 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Eine kritische Schwachstelle wurde in D-Link DAR-8000-10 bis 20230819 entdeckt. Hierbei geht es um eine nicht exakt ausgemachte Funktion der Datei /log/decodmail.php. Mittels Manipulieren des Arguments file mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Die Komplexit\u00e4t eines Angriffs ist eher hoch. Sie ist schwierig ausnutzbar. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 4.6, "vectorString": "AV:N/AC:H/Au:S/C:P/I:P/A:P", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 OS Command Injection", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-10-24T15:08:26.452Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.238574" }, { "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.238574" }, { "tags": [ "exploit" ], "url": "https://github.com/TinkAnet/cve/blob/main/rce.md" } ], "timeline": [ { "lang": "en", "time": "2023-09-01T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2023-09-01T00:00:00.000Z", "value": "CVE reserved" }, { "lang": "en", "time": "2023-09-01T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2023-09-29T13:22:05.000Z", "value": "VulDB entry last update" } ], "title": "D-Link DAR-8000-10 decodmail.php os command injection" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2023-4711", "datePublished": "2023-09-01T19:00:07.967Z", "dateReserved": "2023-09-01T12:43:33.375Z", "dateUpdated": "2024-08-02T07:37:59.572Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2023-08-25 22:15
Modified
2024-11-21 08:35
Severity ?
6.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability was found in D-Link DAR-8000-10 up to 20230809. It has been classified as critical. This affects an unknown part of the file /app/sys1.php. The manipulation of the argument cmd with the input id leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-238047. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/PumpkinBridge/cve/blob/main/rce.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.238047 | Permissions Required, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?id.238047 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/PumpkinBridge/cve/blob/main/rce.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.238047 | Permissions Required, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.238047 | Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
dlink | dar-8000-10_firmware | * | |
dlink | dar-8000-10 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dar-8000-10_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5D24E42C-A511-4AB7-A6AC-D6036869B481", "versionEndIncluding": "2023-08-09", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dar-8000-10:-:*:*:*:*:*:*:*", "matchCriteriaId": "D44DF047-CB1C-47CE-AC33-60F8859F242F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in D-Link DAR-8000-10 up to 20230809. It has been classified as critical. This affects an unknown part of the file /app/sys1.php. The manipulation of the argument cmd with the input id leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-238047. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." } ], "id": "CVE-2023-4542", "lastModified": "2024-11-21T08:35:22.903", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 6.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.4, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-25T22:15:11.457", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/PumpkinBridge/cve/blob/main/rce.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "Third Party Advisory" ], "url": "https://vuldb.com/?ctiid.238047" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.238047" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/PumpkinBridge/cve/blob/main/rce.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "Third Party Advisory" ], "url": "https://vuldb.com/?ctiid.238047" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.238047" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "cna@vuldb.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-09-01 20:15
Modified
2024-11-21 08:35
Severity ?
5.0 (Medium) - CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:L/I:L/A:L
8.1 (High) - CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
8.1 (High) - CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability, which was classified as critical, has been found in D-Link DAR-8000-10 up to 20230819. Affected by this issue is some unknown functionality of the file /log/decodmail.php. The manipulation of the argument file leads to os command injection. The attack may be launched remotely. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. VDB-238574 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/TinkAnet/cve/blob/main/rce.md | Exploit | |
cna@vuldb.com | https://vuldb.com/?ctiid.238574 | Permissions Required, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.238574 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/TinkAnet/cve/blob/main/rce.md | Exploit | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.238574 | Permissions Required, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.238574 | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
dlink | dar-8000-10_firmware | * | |
dlink | dar-8000-10 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dar-8000-10_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B402A316-BDF5-4E14-A81F-CEA0161B33FA", "versionEndIncluding": "20230819", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dar-8000-10:-:*:*:*:*:*:*:*", "matchCriteriaId": "D44DF047-CB1C-47CE-AC33-60F8859F242F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, has been found in D-Link DAR-8000-10 up to 20230819. Affected by this issue is some unknown functionality of the file /log/decodmail.php. The manipulation of the argument file leads to os command injection. The attack may be launched remotely. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. VDB-238574 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Una vulnerabilidad, clasificada como cr\u00edtica, ha sido encontrada en D-Link DAR-8000-10 hasta 20230819.Una funci\u00f3n desconocida del archivo /log/decodmail.php es afectada por este problema. La manipulaci\u00f3n del argumento \"file\" conduce a la inyecci\u00f3n de comandos de tipo \"os\". El ataque se puede iniciar de forma remota. La complejidad de un ataque es bastante alta. Se sabe que la explotaci\u00f3n es dif\u00edcil. El exploit ha sido revelado al p\u00fablico y puede ser utilizado. VDB-238574 es el identificador asignado a esta vulnerabilidad. NOTA: Se contact\u00f3 primeramente al proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2023-4711", "lastModified": "2024-11-21T08:35:48.547", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "HIGH", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 4.6, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:H/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.0, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" }, "exploitabilityScore": 1.6, "impactScore": 3.4, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.2, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-09-01T20:15:08.310", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit" ], "url": "https://github.com/TinkAnet/cve/blob/main/rce.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.238574" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.238574" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit" ], "url": "https://github.com/TinkAnet/cve/blob/main/rce.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.238574" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.238574" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "cna@vuldb.com", "type": "Primary" } ] }