Search

Find a vulnerability

Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    6 vulnerabilities found for control_for_linux_arm_sl by codesys

    CVE-2025-41738 (GCVE-0-2025-41738)

    Vulnerability from nvd – Published: 2025-12-01 10:02 – Updated: 2025-12-01 14:00
    VLAI
    Title
    CODESYS Control - Invalid type usage in visualization
    Summary
    An unauthenticated remote attacker may cause the visualisation server of the CODESYS Control runtime system to access a resource with a pointer of wrong type, potentially leading to a denial-of-service (DoS) condition.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-843 - Access of Resource Using Incompatible Type ('Type Confusion')
    Assigner
    References
    Impacted products
    Vendor Product Version
    CODESYS CODESYS Control RTE (SL) Affected: 3.5.18.0 , < 3.5.21.40 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control RTE (for Beckhoff CX) SL Affected: 3.5.18.0 , < 3.5.21.40 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control Win (SL) Affected: 3.5.18.0 , < 3.5.21.40 (semver)
    Create a notification for this product.
    CODESYS CODESYS HMI (SL) Affected: 3.5.18.0 , < 3.5.21.40 (semver)
    Create a notification for this product.
    CODESYS CODESYS Remote Target Visu Affected: 3.5.18.0 , < 3.5.21.40 (semver)
    Create a notification for this product.
    CODESYS CODESYS Runtime Toolkit Affected: 3.5.18.0 , < 3.5.21.40 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for BeagleBone SL Affected: 4.5.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for emPC-A/iMX6 SL Affected: 4.5.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for IOT2000 SL Affected: 4.5.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for Linux ARM SL Affected: 4.5.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for Linux SL Affected: 4.5.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for PFC100 SL Affected: 4.5.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for PFC200 SL Affected: 4.5.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for PLCnext SL Affected: 4.5.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for Raspberry Pi SL Affected: 4.5.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for WAGO Touch Panels 600 SL Affected: 4.5.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Virtual Control SL Affected: 4.5.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41738",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-01T13:59:44.375519Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-01T14:00:28.509Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control RTE (SL)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.40",
                  "status": "affected",
                  "version": "3.5.18.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control RTE (for Beckhoff CX) SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.40",
                  "status": "affected",
                  "version": "3.5.18.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control Win (SL)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.40",
                  "status": "affected",
                  "version": "3.5.18.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS HMI (SL)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.40",
                  "status": "affected",
                  "version": "3.5.18.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Remote Target Visu",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.40",
                  "status": "affected",
                  "version": "3.5.18.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Runtime Toolkit",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.40",
                  "status": "affected",
                  "version": "3.5.18.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for BeagleBone SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for emPC-A/iMX6 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for IOT2000 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for Linux ARM SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for Linux SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for PFC100 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for PFC200 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for PLCnext SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for Raspberry Pi SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for WAGO Touch Panels 600 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Virtual Control SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.5.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An unauthenticated remote attacker may cause the visualisation server of the CODESYS Control runtime system to access a resource with a pointer of wrong type, potentially leading to a denial-of-service (DoS) condition.\u003cbr\u003e"
                }
              ],
              "value": "An unauthenticated remote attacker may cause the visualisation server of the CODESYS Control runtime system to access a resource with a pointer of wrong type, potentially leading to a denial-of-service (DoS) condition."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-843",
                  "description": "CWE-843 Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-01T10:02:33.407Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://certvde.com/de/advisories/VDE-2025-100"
            }
          ],
          "source": {
            "advisory": "VDE-2025-100",
            "defect": [
              "CERT@VDE#641889"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "CODESYS Control - Invalid type usage in visualization",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-41738",
        "datePublished": "2025-12-01T10:02:33.407Z",
        "dateReserved": "2025-04-16T11:17:48.320Z",
        "dateUpdated": "2025-12-01T14:00:28.509Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2023-6357 (GCVE-0-2023-6357)

    Vulnerability from nvd – Published: 2023-12-05 14:29 – Updated: 2024-08-02 08:28
    VLAI
    Title
    OS Command Injection in multiple CODESYS products
    Summary
    A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device.
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    Date Public
    2023-12-05 14:25
    Credits
    Chuya Hayakawa of 00One, Inc.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T08:28:21.783Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://https://cert.vde.com/en/advisories/VDE-2023-066"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for BeagleBone SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.11.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for emPC-A/iMX6 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.11.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for IOT2000 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.11.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for Linux ARM SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.11.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for Linux SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.11.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for PFC100 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.11.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for PFC200 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.11.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for PLCnext SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.11.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for Raspberry Pi SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.11.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for WAGO Touch Panels 600 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.11.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Runtime Toolkit for Linux or QNX",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.19.50",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Chuya Hayakawa of 00One, Inc."
            }
          ],
          "datePublic": "2023-12-05T14:25:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device."
                }
              ],
              "value": "A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-12-05T14:29:25.649Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://https://cert.vde.com/en/advisories/VDE-2023-066"
            }
          ],
          "source": {
            "advisory": "VDE-2023-066",
            "defect": [
              "CERT@VDE#64623"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "OS Command Injection in multiple CODESYS products",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2023-6357",
        "datePublished": "2023-12-05T14:29:25.649Z",
        "dateReserved": "2023-11-28T07:20:59.774Z",
        "dateUpdated": "2024-08-02T08:28:21.783Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-29242 (GCVE-0-2021-29242)

    Vulnerability from nvd – Published: 2021-05-03 13:56 – Updated: 2024-08-03 22:02
    VLAI
    Summary
    CODESYS Control Runtime system before 3.5.17.0 has improper input validation. Attackers can send crafted communication packets to change the router's addressing scheme and may re-route, add, remove or change low level communication packages.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T22:02:51.582Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://customers.codesys.com/index.php"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.codesys.com/security/security-reports.html"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=14640\u0026token=623b6fceb0579ef0f7505e29beefa5b3f8ac7873\u0026download="
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "CODESYS Control Runtime system before 3.5.17.0 has improper input validation. Attackers can send crafted communication packets to change the router\u0027s addressing scheme and may re-route, add, remove or change low level communication packages."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-05-03T13:56:06.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://customers.codesys.com/index.php"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.codesys.com/security/security-reports.html"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=14640\u0026token=623b6fceb0579ef0f7505e29beefa5b3f8ac7873\u0026download="
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-29242",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "CODESYS Control Runtime system before 3.5.17.0 has improper input validation. Attackers can send crafted communication packets to change the router\u0027s addressing scheme and may re-route, add, remove or change low level communication packages."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://customers.codesys.com/index.php",
                  "refsource": "MISC",
                  "url": "https://customers.codesys.com/index.php"
                },
                {
                  "name": "https://www.codesys.com/security/security-reports.html",
                  "refsource": "MISC",
                  "url": "https://www.codesys.com/security/security-reports.html"
                },
                {
                  "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=14640\u0026token=623b6fceb0579ef0f7505e29beefa5b3f8ac7873\u0026download=",
                  "refsource": "MISC",
                  "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=14640\u0026token=623b6fceb0579ef0f7505e29beefa5b3f8ac7873\u0026download="
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-29242",
        "datePublished": "2021-05-03T13:56:06.000Z",
        "dateReserved": "2021-03-25T00:00:00.000Z",
        "dateUpdated": "2024-08-03T22:02:51.582Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-41738 (GCVE-0-2025-41738)

    Vulnerability from cvelistv5 – Published: 2025-12-01 10:02 – Updated: 2025-12-01 14:00
    VLAI
    Title
    CODESYS Control - Invalid type usage in visualization
    Summary
    An unauthenticated remote attacker may cause the visualisation server of the CODESYS Control runtime system to access a resource with a pointer of wrong type, potentially leading to a denial-of-service (DoS) condition.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-843 - Access of Resource Using Incompatible Type ('Type Confusion')
    Assigner
    References
    Impacted products
    Vendor Product Version
    CODESYS CODESYS Control RTE (SL) Affected: 3.5.18.0 , < 3.5.21.40 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control RTE (for Beckhoff CX) SL Affected: 3.5.18.0 , < 3.5.21.40 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control Win (SL) Affected: 3.5.18.0 , < 3.5.21.40 (semver)
    Create a notification for this product.
    CODESYS CODESYS HMI (SL) Affected: 3.5.18.0 , < 3.5.21.40 (semver)
    Create a notification for this product.
    CODESYS CODESYS Remote Target Visu Affected: 3.5.18.0 , < 3.5.21.40 (semver)
    Create a notification for this product.
    CODESYS CODESYS Runtime Toolkit Affected: 3.5.18.0 , < 3.5.21.40 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for BeagleBone SL Affected: 4.5.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for emPC-A/iMX6 SL Affected: 4.5.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for IOT2000 SL Affected: 4.5.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for Linux ARM SL Affected: 4.5.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for Linux SL Affected: 4.5.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for PFC100 SL Affected: 4.5.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for PFC200 SL Affected: 4.5.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for PLCnext SL Affected: 4.5.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for Raspberry Pi SL Affected: 4.5.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for WAGO Touch Panels 600 SL Affected: 4.5.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Virtual Control SL Affected: 4.5.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41738",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-01T13:59:44.375519Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-01T14:00:28.509Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control RTE (SL)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.40",
                  "status": "affected",
                  "version": "3.5.18.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control RTE (for Beckhoff CX) SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.40",
                  "status": "affected",
                  "version": "3.5.18.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control Win (SL)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.40",
                  "status": "affected",
                  "version": "3.5.18.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS HMI (SL)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.40",
                  "status": "affected",
                  "version": "3.5.18.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Remote Target Visu",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.40",
                  "status": "affected",
                  "version": "3.5.18.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Runtime Toolkit",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.40",
                  "status": "affected",
                  "version": "3.5.18.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for BeagleBone SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for emPC-A/iMX6 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for IOT2000 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for Linux ARM SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for Linux SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for PFC100 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for PFC200 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for PLCnext SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for Raspberry Pi SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for WAGO Touch Panels 600 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.5.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Virtual Control SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.5.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An unauthenticated remote attacker may cause the visualisation server of the CODESYS Control runtime system to access a resource with a pointer of wrong type, potentially leading to a denial-of-service (DoS) condition.\u003cbr\u003e"
                }
              ],
              "value": "An unauthenticated remote attacker may cause the visualisation server of the CODESYS Control runtime system to access a resource with a pointer of wrong type, potentially leading to a denial-of-service (DoS) condition."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-843",
                  "description": "CWE-843 Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-01T10:02:33.407Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://certvde.com/de/advisories/VDE-2025-100"
            }
          ],
          "source": {
            "advisory": "VDE-2025-100",
            "defect": [
              "CERT@VDE#641889"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "CODESYS Control - Invalid type usage in visualization",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-41738",
        "datePublished": "2025-12-01T10:02:33.407Z",
        "dateReserved": "2025-04-16T11:17:48.320Z",
        "dateUpdated": "2025-12-01T14:00:28.509Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2023-6357 (GCVE-0-2023-6357)

    Vulnerability from cvelistv5 – Published: 2023-12-05 14:29 – Updated: 2024-08-02 08:28
    VLAI
    Title
    OS Command Injection in multiple CODESYS products
    Summary
    A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device.
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    Date Public
    2023-12-05 14:25
    Credits
    Chuya Hayakawa of 00One, Inc.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T08:28:21.783Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://https://cert.vde.com/en/advisories/VDE-2023-066"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for BeagleBone SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.11.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for emPC-A/iMX6 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.11.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for IOT2000 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.11.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for Linux ARM SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.11.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for Linux SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.11.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for PFC100 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.11.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for PFC200 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.11.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for PLCnext SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.11.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for Raspberry Pi SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.11.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for WAGO Touch Panels 600 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.11.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Runtime Toolkit for Linux or QNX",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.19.50",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Chuya Hayakawa of 00One, Inc."
            }
          ],
          "datePublic": "2023-12-05T14:25:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device."
                }
              ],
              "value": "A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-12-05T14:29:25.649Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://https://cert.vde.com/en/advisories/VDE-2023-066"
            }
          ],
          "source": {
            "advisory": "VDE-2023-066",
            "defect": [
              "CERT@VDE#64623"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "OS Command Injection in multiple CODESYS products",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2023-6357",
        "datePublished": "2023-12-05T14:29:25.649Z",
        "dateReserved": "2023-11-28T07:20:59.774Z",
        "dateUpdated": "2024-08-02T08:28:21.783Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-29242 (GCVE-0-2021-29242)

    Vulnerability from cvelistv5 – Published: 2021-05-03 13:56 – Updated: 2024-08-03 22:02
    VLAI
    Summary
    CODESYS Control Runtime system before 3.5.17.0 has improper input validation. Attackers can send crafted communication packets to change the router's addressing scheme and may re-route, add, remove or change low level communication packages.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T22:02:51.582Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://customers.codesys.com/index.php"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.codesys.com/security/security-reports.html"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=14640\u0026token=623b6fceb0579ef0f7505e29beefa5b3f8ac7873\u0026download="
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "CODESYS Control Runtime system before 3.5.17.0 has improper input validation. Attackers can send crafted communication packets to change the router\u0027s addressing scheme and may re-route, add, remove or change low level communication packages."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-05-03T13:56:06.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://customers.codesys.com/index.php"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.codesys.com/security/security-reports.html"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=14640\u0026token=623b6fceb0579ef0f7505e29beefa5b3f8ac7873\u0026download="
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-29242",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "CODESYS Control Runtime system before 3.5.17.0 has improper input validation. Attackers can send crafted communication packets to change the router\u0027s addressing scheme and may re-route, add, remove or change low level communication packages."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://customers.codesys.com/index.php",
                  "refsource": "MISC",
                  "url": "https://customers.codesys.com/index.php"
                },
                {
                  "name": "https://www.codesys.com/security/security-reports.html",
                  "refsource": "MISC",
                  "url": "https://www.codesys.com/security/security-reports.html"
                },
                {
                  "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=14640\u0026token=623b6fceb0579ef0f7505e29beefa5b3f8ac7873\u0026download=",
                  "refsource": "MISC",
                  "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=14640\u0026token=623b6fceb0579ef0f7505e29beefa5b3f8ac7873\u0026download="
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-29242",
        "datePublished": "2021-05-03T13:56:06.000Z",
        "dateReserved": "2021-03-25T00:00:00.000Z",
        "dateUpdated": "2024-08-03T22:02:51.582Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }