Vulnerabilites related to phoenixcontact - axc_f_1152_firmware
Vulnerability from fkie_nvd
Published
2021-09-27 09:15
Modified
2024-11-21 06:10
Summary
Multiple Phoenix Contact PLCnext control devices in versions prior to 2021.0.5 LTS are prone to a DoS attack through special crafted JSON requests.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:plcnext_technology_starterkit_firmware:*:*:*:*:lts:*:*:*",
              "matchCriteriaId": "D3A000A0-3E09-4CC2-B55B-02FF141E9032",
              "versionEndExcluding": "2021.0.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:plcnext_technology_starterkit:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "12BDD2FE-0D7C-4868-A5E4-B1004A5C217D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:axc_f_2152_starterkit_firmware:*:*:*:*:lts:*:*:*",
              "matchCriteriaId": "234711BD-CD61-4A50-9CC7-09619EB68E0B",
              "versionEndExcluding": "2021.0.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:axc_f_2152_starterkit:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "079A104B-2016-4830-80C1-3AB969106649",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:rfc_4072s_firmware:*:*:*:*:lts:*:*:*",
              "matchCriteriaId": "D8AB52B3-C3F7-4900-901D-B90C5D877A9C",
              "versionEndExcluding": "2021.0.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:rfc_4072s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0BF1EAD1-7C19-4A6E-BF87-EF3F7E526BD6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:axc_f_3152_firmware:*:*:*:*:lts:*:*:*",
              "matchCriteriaId": "D4FC9F69-D10F-47AF-A5BA-B7AB46FB3389",
              "versionEndExcluding": "2021.0.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:axc_f_3152:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "57424998-4EAB-4682-BFC4-1D2A621514F4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:axc_f_1152_firmware:*:*:*:*:lts:*:*:*",
              "matchCriteriaId": "17D8F2FA-C7D4-4D79-9356-4E74D7D84133",
              "versionEndExcluding": "2021.0.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:axc_f_1152:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A2474BD7-C447-4E07-A628-C729E376943D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:axc_f_2152_firmware:*:*:*:*:lts:*:*:*",
              "matchCriteriaId": "73852309-933E-476F-865E-BC4B25ABF797",
              "versionEndExcluding": "2021.0.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:axc_f_2152:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE2E6118-6587-444A-A143-9C3A1E6ED4FD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Multiple Phoenix Contact PLCnext control devices in versions prior to 2021.0.5 LTS are prone to a DoS attack through special crafted JSON requests."
    },
    {
      "lang": "es",
      "value": "M\u00faltiples dispositivos de control Phoenix Contact PLCnext en versiones anteriores a 2021.0.5 LTS, son propensos a un ataque DoS mediante peticiones JSON especialmente dise\u00f1adas"
    }
  ],
  "id": "CVE-2021-34570",
  "lastModified": "2024-11-21T06:10:43.373",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "info@cert.vde.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-09-27T09:15:07.750",
  "references": [
    {
      "source": "info@cert.vde.com",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://cert.vde.com/en/advisories/VDE-2021-029/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://cert.vde.com/en/advisories/VDE-2021-029/"
    }
  ],
  "sourceIdentifier": "info@cert.vde.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ],
      "source": "info@cert.vde.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-12-14 14:15
Modified
2024-11-21 08:27
Summary
A download of code without integrity check vulnerability in PLCnext products allows an remote attacker with low privileges to compromise integrity on the affected engineering station and the connected devices.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:axc_f_1152_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9C72F7B2-43D1-43CB-B611-B57487E9AE53",
              "versionEndIncluding": "2024.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:axc_f_1152:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A2474BD7-C447-4E07-A628-C729E376943D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:axc_f_2152_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4EA16E9E-ADBB-4943-AE2D-7C49F882A809",
              "versionEndIncluding": "2024.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:axc_f_2152:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE2E6118-6587-444A-A143-9C3A1E6ED4FD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:axc_f_3152_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E28DCF3B-C26E-44BE-BCA1-0AED56326FC3",
              "versionEndIncluding": "2024.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:axc_f_3152:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "57424998-4EAB-4682-BFC4-1D2A621514F4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:bpc_9102s_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A97B1250-2830-4EFC-9393-DF96E129E16D",
              "versionEndIncluding": "2024.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:bpc_9102s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "346E85EB-8800-40C7-A7DA-EA587CF90F08",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:epc_1502_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8E7E962-9BA0-418B-8A43-541C5278C9ED",
              "versionEndIncluding": "2024.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:epc_1502:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "85AF0A71-02C4-4CFF-A820-5C326F066024",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:epc_1522_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E3671BE8-A1DE-444E-9A24-5C86E4F0BBF1",
              "versionEndIncluding": "2024.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:epc_1522:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBD531B6-09DA-4B4A-AA7C-C2A54B089C67",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:phoenixcontact:plcnext_engineer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C6A5C5E9-4F2C-44BC-8B64-29D25C789643",
              "versionEndIncluding": "2024.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:rfc_4072r_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE1D89DD-1717-4E84-8A33-82AA29594E7D",
              "versionEndIncluding": "2024.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:rfc_4072r:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "65D9C540-F273-4EA8-8FF6-95DF46B01D89",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:rfc_4072s_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E633B5AB-BD27-461D-8083-20CC1C768D34",
              "versionEndIncluding": "2024.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:rfc_4072s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0BF1EAD1-7C19-4A6E-BF87-EF3F7E526BD6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A download of code without integrity check vulnerability in PLCnext products allows an remote attacker with low privileges to compromise integrity on the affected engineering station and the connected devices."
    },
    {
      "lang": "es",
      "value": "Una descarga de c\u00f3digo sin vulnerabilidad de verificaci\u00f3n de integridad en los productos PLCnext permite que un atacante remoto con privilegios bajos comprometa la integridad de la estaci\u00f3n de ingenier\u00eda afectada y los dispositivos conectados."
    }
  ],
  "id": "CVE-2023-46144",
  "lastModified": "2024-11-21T08:27:58.380",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "info@cert.vde.com",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Secondary"
      }
    ]
  },
  "published": "2023-12-14T14:15:43.447",
  "references": [
    {
      "source": "info@cert.vde.com",
      "tags": [
        "Broken Link"
      ],
      "url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Broken Link"
      ],
      "url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
    }
  ],
  "sourceIdentifier": "info@cert.vde.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-494"
        }
      ],
      "source": "info@cert.vde.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-12-14 14:15
Modified
2024-11-21 08:27
Summary
A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:axc_f_1152_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9C72F7B2-43D1-43CB-B611-B57487E9AE53",
              "versionEndIncluding": "2024.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:axc_f_1152:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A2474BD7-C447-4E07-A628-C729E376943D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:axc_f_2152_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4EA16E9E-ADBB-4943-AE2D-7C49F882A809",
              "versionEndIncluding": "2024.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:axc_f_2152:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE2E6118-6587-444A-A143-9C3A1E6ED4FD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:axc_f_3152_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E28DCF3B-C26E-44BE-BCA1-0AED56326FC3",
              "versionEndIncluding": "2024.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:axc_f_3152:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "57424998-4EAB-4682-BFC4-1D2A621514F4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:bpc_9102s_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A97B1250-2830-4EFC-9393-DF96E129E16D",
              "versionEndIncluding": "2024.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:bpc_9102s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "346E85EB-8800-40C7-A7DA-EA587CF90F08",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:epc_1502_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8E7E962-9BA0-418B-8A43-541C5278C9ED",
              "versionEndIncluding": "2024.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:epc_1502:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "85AF0A71-02C4-4CFF-A820-5C326F066024",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:epc_1522_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E3671BE8-A1DE-444E-9A24-5C86E4F0BBF1",
              "versionEndIncluding": "2024.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:epc_1522:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBD531B6-09DA-4B4A-AA7C-C2A54B089C67",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:phoenixcontact:plcnext_engineer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C6A5C5E9-4F2C-44BC-8B64-29D25C789643",
              "versionEndIncluding": "2024.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:rfc_4072r_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE1D89DD-1717-4E84-8A33-82AA29594E7D",
              "versionEndIncluding": "2024.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:rfc_4072r:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "65D9C540-F273-4EA8-8FF6-95DF46B01D89",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:rfc_4072s_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E633B5AB-BD27-461D-8083-20CC1C768D34",
              "versionEndIncluding": "2024.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:rfc_4072s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0BF1EAD1-7C19-4A6E-BF87-EF3F7E526BD6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices."
    },
    {
      "lang": "es",
      "value": "Una asignaci\u00f3n de permiso incorrecta para una vulnerabilidad de recursos cr\u00edticos en los productos PLCnext permite que un atacante remoto con privilegios bajos obtenga acceso completo a los dispositivos afectados."
    }
  ],
  "id": "CVE-2023-46142",
  "lastModified": "2024-11-21T08:27:58.077",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "info@cert.vde.com",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-12-14T14:15:42.983",
  "references": [
    {
      "source": "info@cert.vde.com",
      "tags": [
        "Broken Link"
      ],
      "url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Broken Link"
      ],
      "url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
    }
  ],
  "sourceIdentifier": "info@cert.vde.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-732"
        }
      ],
      "source": "info@cert.vde.com",
      "type": "Primary"
    }
  ]
}

cve-2023-46142
Vulnerability from cvelistv5
Published
2023-12-14 14:05
Modified
2024-08-02 20:37
Summary
A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T20:37:39.840Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "AXC F 1152",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "lessThanOrEqual": "2024.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "AXC F 2152",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "lessThanOrEqual": "2024.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "AXC F 3152",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "lessThanOrEqual": "2024.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "BPC 9102S",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "lessThanOrEqual": "2024.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EPC 1502",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "lessThanOrEqual": "2024.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EPC 1522",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "lessThanOrEqual": "2024.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PLCnext Engineer",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "lessThanOrEqual": "2024.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "RFC 4072R",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "lessThanOrEqual": "2024.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "RFC 4072S",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "lessThanOrEqual": "2024.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Reid Wightman of Dragos, Inc."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices."
            }
          ],
          "value": "A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-732",
              "description": "CWE-732: Incorrect Permission Assignment for Critical Resource",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-12-14T14:05:35.741Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
        }
      ],
      "source": {
        "advisory": "VDE-2023-056",
        "defect": [
          "CERT@VDE#64609"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "PHOENIX CONTACT: Insufficient Read and Write Protection to Logic and Runtime Data in PLCnext Control",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2023-46142",
    "datePublished": "2023-12-14T14:05:35.741Z",
    "dateReserved": "2023-10-17T07:04:03.576Z",
    "dateUpdated": "2024-08-02T20:37:39.840Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-34570
Vulnerability from cvelistv5
Published
2021-09-27 08:25
Modified
2024-09-16 22:09
Summary
Multiple Phoenix Contact PLCnext control devices in versions prior to 2021.0.5 LTS are prone to a DoS attack through special crafted JSON requests.
References
https://cert.vde.com/en/advisories/VDE-2021-029/x_refsource_CONFIRM
Impacted products
Vendor Product Version
Phoenix Contact AXC F Version: AXC F 1152 (1151412)   < 2021.0.5 LTS
Version: AXC F 2152 (2404267)   < 2021.0.5 LTS
Version: AXC F 3152 (1069208)   < 2021.0.5 LTS
Version: AXC F 2152 Starterkit (1046568)   < 2021.0.5 LTS
Create a notification for this product.
   Phoenix Contact RFC Version: RFC 4072S (1051328)   < 2021.0.5 LTS
Create a notification for this product.
   Phoenix Contact PLCnext Version: PLCnext Technology Starterkit (1188165)   < 2021.0.5 LTS
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T00:12:50.435Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en/advisories/VDE-2021-029/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AXC F",
          "vendor": "Phoenix Contact",
          "versions": [
            {
              "lessThan": "2021.0.5 LTS",
              "status": "affected",
              "version": "AXC F 1152 (1151412)",
              "versionType": "custom"
            },
            {
              "lessThan": "2021.0.5 LTS",
              "status": "affected",
              "version": "AXC F 2152 (2404267)",
              "versionType": "custom"
            },
            {
              "lessThan": "2021.0.5 LTS",
              "status": "affected",
              "version": "AXC F 3152 (1069208)",
              "versionType": "custom"
            },
            {
              "lessThan": "2021.0.5 LTS",
              "status": "affected",
              "version": "AXC F 2152 Starterkit (1046568)",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "RFC",
          "vendor": "Phoenix Contact",
          "versions": [
            {
              "lessThan": "2021.0.5 LTS",
              "status": "affected",
              "version": "RFC 4072S (1051328)",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "PLCnext",
          "vendor": "Phoenix Contact",
          "versions": [
            {
              "lessThan": "2021.0.5 LTS",
              "status": "affected",
              "version": "PLCnext Technology Starterkit (1188165)",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "The vulnerability was discovered by Oliver Carrigan of Dionach. We kindly appreciate the coordinated disclosure of these vulnerabilities by the finder.  PHOENIX CONTACT thanks CERT@VDE for the coordination and support with this publication."
        }
      ],
      "datePublic": "2021-08-03T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Multiple Phoenix Contact PLCnext control devices in versions prior to 2021.0.5 LTS are prone to a DoS attack through special crafted JSON requests."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20 Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-09-27T08:25:09",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-029/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Phoenix Contact recommends affected users to upgrade to the current Firmware 2021.0.5 LTS or higher which fixes this vulnerability."
        }
      ],
      "source": {
        "advisory": "VDE-2021-029",
        "discovery": "EXTERNAL"
      },
      "title": "Phoenix Contact: DoS for PLCnext Control devices in versions prior to 2021.0.5 LTS",
      "workarounds": [
        {
          "lang": "en",
          "value": "Phoenix Contact recommends operating network-capable devices in closed networks or protected with a suitable firewall. For detailed information on our recommendations for measures to protect network-capable devices, please refer to our application note:\nMeasures to protect network-capable devices with Ethernet connection"
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "info@cert.vde.com",
          "DATE_PUBLIC": "2021-08-03T22:00:00.000Z",
          "ID": "CVE-2021-34570",
          "STATE": "PUBLIC",
          "TITLE": "Phoenix Contact: DoS for PLCnext Control devices in versions prior to 2021.0.5 LTS"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "AXC F",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "AXC F 1152 (1151412)",
                            "version_value": "2021.0.5 LTS"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "AXC F 2152 (2404267)",
                            "version_value": "2021.0.5 LTS"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "AXC F 3152 (1069208)",
                            "version_value": "2021.0.5 LTS"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "AXC F 2152 Starterkit (1046568)",
                            "version_value": "2021.0.5 LTS"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "RFC",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "RFC 4072S (1051328)",
                            "version_value": "2021.0.5 LTS"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "PLCnext",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "PLCnext Technology Starterkit (1188165)",
                            "version_value": "2021.0.5 LTS"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Phoenix Contact"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "The vulnerability was discovered by Oliver Carrigan of Dionach. We kindly appreciate the coordinated disclosure of these vulnerabilities by the finder.  PHOENIX CONTACT thanks CERT@VDE for the coordination and support with this publication."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Multiple Phoenix Contact PLCnext control devices in versions prior to 2021.0.5 LTS are prone to a DoS attack through special crafted JSON requests."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-20 Improper Input Validation"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert.vde.com/en/advisories/VDE-2021-029/",
              "refsource": "CONFIRM",
              "url": "https://cert.vde.com/en/advisories/VDE-2021-029/"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Phoenix Contact recommends affected users to upgrade to the current Firmware 2021.0.5 LTS or higher which fixes this vulnerability."
          }
        ],
        "source": {
          "advisory": "VDE-2021-029",
          "discovery": "EXTERNAL"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "Phoenix Contact recommends operating network-capable devices in closed networks or protected with a suitable firewall. For detailed information on our recommendations for measures to protect network-capable devices, please refer to our application note:\nMeasures to protect network-capable devices with Ethernet connection"
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2021-34570",
    "datePublished": "2021-09-27T08:25:09.502074Z",
    "dateReserved": "2021-06-10T00:00:00",
    "dateUpdated": "2024-09-16T22:09:31.616Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-46144
Vulnerability from cvelistv5
Published
2023-12-14 14:08
Modified
2024-10-01 06:18
Summary
A download of code without integrity check vulnerability in PLCnext products allows an remote attacker with low privileges to compromise integrity on the affected engineering station and the connected devices.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T20:37:39.934Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "AXC F 1152",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "lessThanOrEqual": "2024.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "AXC F 2152",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "lessThanOrEqual": "2024.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "AXC F 3152",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "lessThanOrEqual": "2024.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "BPC 9102S",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "lessThanOrEqual": "2024.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EPC 1502",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "lessThanOrEqual": "2024.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EPC 1522",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "lessThanOrEqual": "2024.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PLCnext Engineer",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "lessThanOrEqual": "2024.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "RFC 4072R",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "lessThanOrEqual": "2024.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "RFC 4072S",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "lessThanOrEqual": "2024.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Reid Wightman of Dragos, Inc."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A download of code without integrity check vulnerability in PLCnext products allows an remote attacker with low privileges to compromise integrity on the affected engineering station and the connected devices."
            }
          ],
          "value": "A download of code without integrity check vulnerability in PLCnext products allows an remote attacker with low privileges to compromise integrity on the affected engineering station and the connected devices."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-494",
              "description": "CWE-494: Download of Code Without Integrity Check",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-01T06:18:18.730Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
        }
      ],
      "source": {
        "advisory": "VDE-2023-058",
        "defect": [
          "CERT@VDE#64611"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "PHOENIX CONTACT: PLCnext Control prone to download of code without integrity check",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2023-46144",
    "datePublished": "2023-12-14T14:08:07.244Z",
    "dateReserved": "2023-10-17T07:04:03.577Z",
    "dateUpdated": "2024-10-01T06:18:18.730Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}