Vulnerabilites related to tendacn - ac9v1.0_firmware
Vulnerability from fkie_nvd
Published
2019-11-21 17:15
Modified
2024-11-21 04:44
Summary
An exploitable command injection vulnerability exists in the /goform/WanParameterSetting functionality of Tenda AC9 Router AC1200 Smart Dual-Band Gigabit WiFi Route (AC9V1.0 Firmware V15.03.05.16multiTRU). A specially crafted HTTP POST request can cause a command injection in the DNS2 post parameters, resulting in code execution. An attacker can send HTTP POST request with command to trigger this vulnerability.
Impacted products
Vendor Product Version
tendacn ac9v1.0_firmware 15.03.05.14_en
tendacn ac9v1.0_firmware 15.03.05.16multitru
tendacn ac1200_smart_dual-band_gigabit_wifi -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tendacn:ac9v1.0_firmware:15.03.05.14_en:*:*:*:*:*:*:*",
              "matchCriteriaId": "7403ADB2-1808-4EE8-A715-CFEEAE46F97D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:tendacn:ac9v1.0_firmware:15.03.05.16multitru:*:*:*:*:*:*:*",
              "matchCriteriaId": "D856F015-CD06-41CC-9A09-BA5557572D79",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tendacn:ac1200_smart_dual-band_gigabit_wifi:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "376DD8B9-10C3-4302-9697-9F11F3020E1B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An exploitable command injection vulnerability exists in the /goform/WanParameterSetting functionality of Tenda AC9 Router AC1200 Smart Dual-Band Gigabit WiFi Route (AC9V1.0 Firmware V15.03.05.16multiTRU). A specially crafted HTTP POST request can cause a command injection in the DNS2 post parameters, resulting in code execution. An attacker can send HTTP POST request with command to trigger this vulnerability."
    },
    {
      "lang": "es",
      "value": "Se presenta una vulnerabilidad de inyecci\u00f3n de comandos explotable en la funcionalidad /goform/WanParameterSetting de Tenda AC9 Router AC1200 Smart Dual-Band Gigabit WiFi Route (Firmware AC9V1.0 versi\u00f3n V15.03.05.16multiTRU). Una petici\u00f3n HTTP POST especialmente dise\u00f1ada puede causar una inyecci\u00f3n de comando en los par\u00e1metros de publicaci\u00f3n de DNS2, resultando en la ejecuci\u00f3n de c\u00f3digo. Un atacante puede enviar una petici\u00f3n HTTP POST con un comando para activar esta vulnerabilidad."
    }
  ],
  "id": "CVE-2019-5072",
  "lastModified": "2024-11-21T04:44:17.803",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 4.6,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "talos-cna@cisco.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-11-21T17:15:12.147",
  "references": [
    {
      "source": "talos-cna@cisco.com",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0861"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0861"
    }
  ],
  "sourceIdentifier": "talos-cna@cisco.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ],
      "source": "talos-cna@cisco.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2019-11-21 17:15
Modified
2024-11-21 04:44
Summary
An exploitable command injection vulnerability exists in the /goform/WanParameterSetting functionality of Tenda AC9 Router AC1200 Smart Dual-Band Gigabit WiFi Route (AC9V1.0 Firmware V15.03.05.16multiTRU). A specially crafted HTTP POST request can cause a command injection in the DNS1 post parameters, resulting in code execution. An attacker can send HTTP POST request with command to trigger this vulnerability.
Impacted products
Vendor Product Version
tendacn ac9v1.0_firmware 15.03.05.14_en
tendacn ac9v1.0_firmware 15.03.05.16multitru
tendacn ac1200_smart_dual-band_gigabit_wifi -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tendacn:ac9v1.0_firmware:15.03.05.14_en:*:*:*:*:*:*:*",
              "matchCriteriaId": "7403ADB2-1808-4EE8-A715-CFEEAE46F97D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:tendacn:ac9v1.0_firmware:15.03.05.16multitru:*:*:*:*:*:*:*",
              "matchCriteriaId": "D856F015-CD06-41CC-9A09-BA5557572D79",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tendacn:ac1200_smart_dual-band_gigabit_wifi:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "376DD8B9-10C3-4302-9697-9F11F3020E1B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An exploitable command injection vulnerability exists in the /goform/WanParameterSetting functionality of Tenda AC9 Router AC1200 Smart Dual-Band Gigabit WiFi Route (AC9V1.0 Firmware V15.03.05.16multiTRU). A specially crafted HTTP POST request can cause a command injection in the DNS1 post parameters, resulting in code execution. An attacker can send HTTP POST request with command to trigger this vulnerability."
    },
    {
      "lang": "es",
      "value": "Se presenta una vulnerabilidad de inyecci\u00f3n de comandos explotable en la funcionalidad /goform/WanParameterSetting de Tenda AC9 Router AC1200 Smart Dual-Band Gigabit WiFi Route (Firmware AC9V1.0 versi\u00f3n V15.03.05.16multiTRU). Una petici\u00f3n HTTP POST especialmente dise\u00f1ada puede causar una inyecci\u00f3n de comando en los par\u00e1metros de publicaci\u00f3n de DNS1, resultando en la ejecuci\u00f3n de c\u00f3digo. Un atacante puede enviar una petici\u00f3n HTTP POST con un comando para activar esta vulnerabilidad."
    }
  ],
  "id": "CVE-2019-5071",
  "lastModified": "2024-11-21T04:44:17.677",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.2,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "talos-cna@cisco.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-11-21T17:15:12.057",
  "references": [
    {
      "source": "talos-cna@cisco.com",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0861"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0861"
    }
  ],
  "sourceIdentifier": "talos-cna@cisco.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ],
      "source": "talos-cna@cisco.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

cve-2019-5072
Vulnerability from cvelistv5
Published
2019-11-21 16:16
Modified
2024-08-04 19:47
Summary
An exploitable command injection vulnerability exists in the /goform/WanParameterSetting functionality of Tenda AC9 Router AC1200 Smart Dual-Band Gigabit WiFi Route (AC9V1.0 Firmware V15.03.05.16multiTRU). A specially crafted HTTP POST request can cause a command injection in the DNS2 post parameters, resulting in code execution. An attacker can send HTTP POST request with command to trigger this vulnerability.
Impacted products
Vendor Product Version
n/a Tenda AC9 Version: AC9V1.0 Firmware V15.03.05.16multiTRU AC9V1.0 Firmware V15.03.05.14_EN
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T19:47:55.651Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0861"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Tenda AC9",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "AC9V1.0 Firmware V15.03.05.16multiTRU AC9V1.0 Firmware V15.03.05.14_EN"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An exploitable command injection vulnerability exists in the /goform/WanParameterSetting functionality of Tenda AC9 Router AC1200 Smart Dual-Band Gigabit WiFi Route (AC9V1.0 Firmware V15.03.05.16multiTRU). A specially crafted HTTP POST request can cause a command injection in the DNS2 post parameters, resulting in code execution. An attacker can send HTTP POST request with command to trigger this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-19T17:33:50",
        "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
        "shortName": "talos"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0861"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "talos-cna@cisco.com",
          "ID": "CVE-2019-5072",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Tenda AC9",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "AC9V1.0 Firmware V15.03.05.16multiTRU AC9V1.0 Firmware V15.03.05.14_EN"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An exploitable command injection vulnerability exists in the /goform/WanParameterSetting functionality of Tenda AC9 Router AC1200 Smart Dual-Band Gigabit WiFi Route (AC9V1.0 Firmware V15.03.05.16multiTRU). A specially crafted HTTP POST request can cause a command injection in the DNS2 post parameters, resulting in code execution. An attacker can send HTTP POST request with command to trigger this vulnerability."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 7.8,
            "baseSeverity": "High",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0861",
              "refsource": "MISC",
              "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0861"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
    "assignerShortName": "talos",
    "cveId": "CVE-2019-5072",
    "datePublished": "2019-11-21T16:16:06",
    "dateReserved": "2019-01-04T00:00:00",
    "dateUpdated": "2024-08-04T19:47:55.651Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-5071
Vulnerability from cvelistv5
Published
2019-11-21 16:15
Modified
2024-08-04 19:47
Summary
An exploitable command injection vulnerability exists in the /goform/WanParameterSetting functionality of Tenda AC9 Router AC1200 Smart Dual-Band Gigabit WiFi Route (AC9V1.0 Firmware V15.03.05.16multiTRU). A specially crafted HTTP POST request can cause a command injection in the DNS1 post parameters, resulting in code execution. An attacker can send HTTP POST request with command to trigger this vulnerability.
Impacted products
Vendor Product Version
n/a Tenda AC9 Version: AC9V1.0 Firmware V15.03.05.16multiTRU AC9V1.0 Firmware V15.03.05.14_EN
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T19:47:55.647Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0861"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Tenda AC9",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "AC9V1.0 Firmware V15.03.05.16multiTRU AC9V1.0 Firmware V15.03.05.14_EN"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An exploitable command injection vulnerability exists in the /goform/WanParameterSetting functionality of Tenda AC9 Router AC1200 Smart Dual-Band Gigabit WiFi Route (AC9V1.0 Firmware V15.03.05.16multiTRU). A specially crafted HTTP POST request can cause a command injection in the DNS1 post parameters, resulting in code execution. An attacker can send HTTP POST request with command to trigger this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-19T17:33:49",
        "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
        "shortName": "talos"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0861"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "talos-cna@cisco.com",
          "ID": "CVE-2019-5071",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Tenda AC9",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "AC9V1.0 Firmware V15.03.05.16multiTRU AC9V1.0 Firmware V15.03.05.14_EN"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An exploitable command injection vulnerability exists in the /goform/WanParameterSetting functionality of Tenda AC9 Router AC1200 Smart Dual-Band Gigabit WiFi Route (AC9V1.0 Firmware V15.03.05.16multiTRU). A specially crafted HTTP POST request can cause a command injection in the DNS1 post parameters, resulting in code execution. An attacker can send HTTP POST request with command to trigger this vulnerability."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 7.8,
            "baseSeverity": "High",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0861",
              "refsource": "MISC",
              "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0861"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
    "assignerShortName": "talos",
    "cveId": "CVE-2019-5071",
    "datePublished": "2019-11-21T16:15:49",
    "dateReserved": "2019-01-04T00:00:00",
    "dateUpdated": "2024-08-04T19:47:55.647Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}