Vulnerability from variot
Tenda AC7 through V15.03.06.44_CN, AC9 through V15.03.05.19(6318)_CN, and AC10 through V15.03.06.23_CN devices have a Stack-based Buffer Overflow via a long limitSpeed or limitSpeedup parameter to an unspecified /goform URI. Tenda AC7 , AC9 ,and AC10 Contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7, AC9 and AC10 are all wireless router products from Tenda. A buffer overflow vulnerability exists in TendaAC715.03.06.44_CN and previous versions, AC915.03.05.19 (6318)_CN and previous versions, and AC1015.03.06.23_CN and earlier. An attacker could exploit the vulnerability with a longer \342\200\230limitSpeed\342\200\231 or \342\200\230limitSpeedup\342\200\231 parameter to cause a denial of service
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201807-1285", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac18", "scope": "lte", "trust": 1.0, "vendor": "tendacn", "version": "15.03.05.19\\(6318\\)_cn" }, { "model": "ac7", "scope": "lte", "trust": 1.0, "vendor": "tendacn", "version": "15.03.06.44_cn" }, { "model": "ac10", "scope": "lte", "trust": 1.0, "vendor": "tendacn", "version": "15.03.06.23_cn" }, { "model": "ac9", "scope": "lte", "trust": 1.0, "vendor": "tendacn", "version": "v15.03.05.19\\(6318\\)_cn" }, { "model": "ac15", "scope": "lte", "trust": 1.0, "vendor": "tendacn", "version": "15.03.05.19_cn" }, { "model": "ac10", "scope": "lte", "trust": 0.8, "vendor": "tenda", "version": "15.03.06.23_cn" }, { "model": "ac15", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac18", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac7", "scope": "lte", "trust": 0.8, "vendor": "tenda", "version": "15.03.06.44_cn" }, { "model": "ac9", "scope": "lte", "trust": 0.8, "vendor": "tenda", "version": "15.03.05.19(6318)_cn" }, { "model": "ac7 \u003c=15.03.06.44 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac10 \u003c=15.03.06.23 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac9 \u003c=15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac7", "scope": "eq", "trust": 0.6, "vendor": "tendacn", "version": "15.03.06.44_cn" }, { "model": "ac10", "scope": "eq", "trust": 0.6, "vendor": "tendacn", "version": "15.03.06.23_cn" }, { "model": "ac9", "scope": "eq", "trust": 0.6, "vendor": "tendacn", "version": "v15.03.05.19\\(6318\\)_cn" }, { "model": "ac18", "scope": "eq", "trust": 0.6, "vendor": "tendacn", "version": "15.03.05.19\\(6318\\)_cn" }, { "model": "ac15", "scope": "eq", "trust": 0.6, "vendor": "tendacn", "version": "15.03.05.19_cn" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-14983" }, { "db": "JVNDB", "id": "JVNDB-2018-008461" }, { "db": "CNNVD", "id": "CNNVD-201807-1668" }, { "db": "NVD", "id": "CVE-2018-14492" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:tendacn:ac10_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tendacn:ac15_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tendacn:ac18_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tendacn:ac7_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tendacn:ac9_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-008461" } ] }, "cve": "CVE-2018-14492", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2018-14492", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2018-14983", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "VHN-124657", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2018-14492", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.8, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2018-14492", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2018-14492", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2018-14983", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-201807-1668", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-124657", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-14983" }, { "db": "VULHUB", "id": "VHN-124657" }, { "db": "JVNDB", "id": "JVNDB-2018-008461" }, { "db": "CNNVD", "id": "CNNVD-201807-1668" }, { "db": "NVD", "id": "CVE-2018-14492" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC7 through V15.03.06.44_CN, AC9 through V15.03.05.19(6318)_CN, and AC10 through V15.03.06.23_CN devices have a Stack-based Buffer Overflow via a long limitSpeed or limitSpeedup parameter to an unspecified /goform URI. Tenda AC7 , AC9 ,and AC10 Contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7, AC9 and AC10 are all wireless router products from Tenda. A buffer overflow vulnerability exists in TendaAC715.03.06.44_CN and previous versions, AC915.03.05.19 (6318)_CN and previous versions, and AC1015.03.06.23_CN and earlier. An attacker could exploit the vulnerability with a longer \\342\\200\\230limitSpeed\\342\\200\\231 or \\342\\200\\230limitSpeedup\\342\\200\\231 parameter to cause a denial of service", "sources": [ { "db": "NVD", "id": "CVE-2018-14492" }, { "db": "JVNDB", "id": "JVNDB-2018-008461" }, { "db": "CNVD", "id": "CNVD-2018-14983" }, { "db": "VULHUB", "id": "VHN-124657" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2018-14492", "trust": 3.1 }, { "db": "JVNDB", "id": "JVNDB-2018-008461", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201807-1668", "trust": 0.7 }, { "db": "CNVD", "id": "CNVD-2018-14983", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-124657", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-14983" }, { "db": "VULHUB", "id": "VHN-124657" }, { "db": "JVNDB", "id": "JVNDB-2018-008461" }, { "db": "CNNVD", "id": "CNNVD-201807-1668" }, { "db": "NVD", "id": "CVE-2018-14492" } ] }, "id": "VAR-201807-1285", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2018-14983" }, { "db": "VULHUB", "id": "VHN-124657" } ], "trust": 1.3446503185714285 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-14983" } ] }, "last_update_date": "2024-11-23T22:52:01.968000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top Page", "trust": 0.8, "url": "https://www.tenda.com.cn/" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-008461" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.1 }, { "problemtype": "CWE-119", "trust": 0.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-124657" }, { "db": "JVNDB", "id": "JVNDB-2018-008461" }, { "db": "NVD", "id": "CVE-2018-14492" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.1, "url": "https://github.com/zillr0/routers/blob/master/tendaoob1.md" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14492" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-14492" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-14983" }, { "db": "VULHUB", "id": "VHN-124657" }, { "db": "JVNDB", "id": "JVNDB-2018-008461" }, { "db": "CNNVD", "id": "CNNVD-201807-1668" }, { "db": "NVD", "id": "CVE-2018-14492" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2018-14983" }, { "db": "VULHUB", "id": "VHN-124657" }, { "db": "JVNDB", "id": "JVNDB-2018-008461" }, { "db": "CNNVD", "id": "CNNVD-201807-1668" }, { "db": "NVD", "id": "CVE-2018-14492" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2018-08-10T00:00:00", "db": "CNVD", "id": "CNVD-2018-14983" }, { "date": "2018-07-21T00:00:00", "db": "VULHUB", "id": "VHN-124657" }, { "date": "2018-10-18T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-008461" }, { "date": "2018-07-21T00:00:00", "db": "CNNVD", "id": "CNNVD-201807-1668" }, { "date": "2018-07-21T12:29:00.333000", "db": "NVD", "id": "CVE-2018-14492" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2018-08-10T00:00:00", "db": "CNVD", "id": "CNVD-2018-14983" }, { "date": "2020-08-24T00:00:00", "db": "VULHUB", "id": "VHN-124657" }, { "date": "2018-10-18T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-008461" }, { "date": "2020-08-25T00:00:00", "db": "CNNVD", "id": "CNNVD-201807-1668" }, { "date": "2024-11-21T03:49:10.740000", "db": "NVD", "id": "CVE-2018-14492" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201807-1668" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Tenda Product buffer error vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-008461" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-201807-1668" } ], "trust": 0.6 } }
var-201809-0930
Vulnerability from variot
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server. While processing the ssid parameter for a POST request, the value is directly used in a sprintf call to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow. plural Tenda Product Contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. Tenda AC7, etc. are all wireless router products of China Tenda. An attacker can use this vulnerability to cause a denial of service. The following products and versions are affected: Tenda AC7 15.03.06.44_CN Version; AC9 15.03.05.19(6318)_CN Version; AC10 15.03.06.23_CN Version; AC15 15.03.05.19_CN Version; AC18 15.03.05.19(6318)_CN Version
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201809-0930", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10", "scope": "eq", "trust": 1.6, "vendor": "tendacn", "version": "15.03.06.23" }, { "model": "ac15", "scope": "eq", "trust": 1.6, "vendor": "tendacn", "version": "15.03.05.19" }, { "model": "ac9", "scope": "eq", "trust": 1.6, "vendor": "tendacn", "version": "15.03.05.19" }, { "model": "ac7", "scope": "eq", "trust": 1.6, "vendor": "tendacn", "version": "15.03.06.44" }, { "model": "ac18", "scope": "lte", "trust": 1.0, "vendor": "tendacn", "version": "15.03.05.19" }, { "model": "ac10", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "15.03.06.23_cn" }, { "model": "ac15", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "15.03.05.19_cn" }, { "model": "ac18", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "15.03.05.19(6318)_cn" }, { "model": "ac7", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "15.03.06.44_cn" }, { "model": "ac9", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "15.03.05.19(6318)_cn" }, { "model": "ac9 15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac7 15.03.06.44 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac10 15.03.06.23 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac15 15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac18 15.03.05.19 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac18", "scope": "eq", "trust": 0.6, "vendor": "tendacn", "version": "15.03.05.19" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-35175" }, { "db": "JVNDB", "id": "JVNDB-2018-009403" }, { "db": "CNNVD", "id": "CNNVD-201809-036" }, { "db": "NVD", "id": "CVE-2018-16333" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:tendacn:ac10_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tendacn:ac15_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tendacn:ac18_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tendacn:ac7_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:tendacn:ac9_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-009403" } ] }, "cve": "CVE-2018-16333", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2018-16333", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2020-35175", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "VHN-126682", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2018-16333", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.8, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2018-16333", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2018-16333", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2020-35175", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201809-036", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-126682", "trust": 0.1, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2018-16333", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-35175" }, { "db": "VULHUB", "id": "VHN-126682" }, { "db": "VULMON", "id": "CVE-2018-16333" }, { "db": "JVNDB", "id": "JVNDB-2018-009403" }, { "db": "CNNVD", "id": "CNNVD-201809-036" }, { "db": "NVD", "id": "CVE-2018-16333" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server. While processing the ssid parameter for a POST request, the value is directly used in a sprintf call to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow. plural Tenda Product Contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. Tenda AC7, etc. are all wireless router products of China Tenda. An attacker can use this vulnerability to cause a denial of service. The following products and versions are affected: Tenda AC7 15.03.06.44_CN Version; AC9 15.03.05.19(6318)_CN Version; AC10 15.03.06.23_CN Version; AC15 15.03.05.19_CN Version; AC18 15.03.05.19(6318)_CN Version", "sources": [ { "db": "NVD", "id": "CVE-2018-16333" }, { "db": "JVNDB", "id": "JVNDB-2018-009403" }, { "db": "CNVD", "id": "CNVD-2020-35175" }, { "db": "VULHUB", "id": "VHN-126682" }, { "db": "VULMON", "id": "CVE-2018-16333" } ], "trust": 2.34 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2018-16333", "trust": 3.2 }, { "db": "JVNDB", "id": "JVNDB-2018-009403", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201809-036", "trust": 0.7 }, { "db": "CNVD", "id": "CNVD-2020-35175", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-126682", "trust": 0.1 }, { "db": "VULMON", "id": "CVE-2018-16333", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-35175" }, { "db": "VULHUB", "id": "VHN-126682" }, { "db": "VULMON", "id": "CVE-2018-16333" }, { "db": "JVNDB", "id": "JVNDB-2018-009403" }, { "db": "CNNVD", "id": "CNNVD-201809-036" }, { "db": "NVD", "id": "CVE-2018-16333" } ] }, "id": "VAR-201809-0930", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2020-35175" }, { "db": "VULHUB", "id": "VHN-126682" } ], "trust": 1.4236169144444446 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-35175" } ] }, "last_update_date": "2024-11-23T22:38:03.789000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top Page", "trust": 0.8, "url": "https://www.tenda.com.cn/" }, { "title": "", "trust": 0.1, "url": "https://github.com/kal1x/iotvulhub " }, { "title": "Routers", "trust": 0.1, "url": "https://github.com/ZIllR0/Routers " } ], "sources": [ { "db": "VULMON", "id": "CVE-2018-16333" }, { "db": "JVNDB", "id": "JVNDB-2018-009403" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-119", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-126682" }, { "db": "JVNDB", "id": "JVNDB-2018-009403" }, { "db": "NVD", "id": "CVE-2018-16333" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.6, "url": "https://github.com/zillr0/routers/blob/master/tenda/oob1.md" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-16333" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-16333" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/119.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://github.com/kal1x/iotvulhub" }, { "trust": 0.1, "url": "https://github.com/zillr0/routers" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-35175" }, { "db": "VULHUB", "id": "VHN-126682" }, { "db": "VULMON", "id": "CVE-2018-16333" }, { "db": "JVNDB", "id": "JVNDB-2018-009403" }, { "db": "CNNVD", "id": "CNNVD-201809-036" }, { "db": "NVD", "id": "CVE-2018-16333" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2020-35175" }, { "db": "VULHUB", "id": "VHN-126682" }, { "db": "VULMON", "id": "CVE-2018-16333" }, { "db": "JVNDB", "id": "JVNDB-2018-009403" }, { "db": "CNNVD", "id": "CNNVD-201809-036" }, { "db": "NVD", "id": "CVE-2018-16333" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-30T00:00:00", "db": "CNVD", "id": "CNVD-2020-35175" }, { "date": "2018-09-02T00:00:00", "db": "VULHUB", "id": "VHN-126682" }, { "date": "2018-09-02T00:00:00", "db": "VULMON", "id": "CVE-2018-16333" }, { "date": "2018-11-19T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-009403" }, { "date": "2018-09-03T00:00:00", "db": "CNNVD", "id": "CNNVD-201809-036" }, { "date": "2018-09-02T03:29:00.620000", "db": "NVD", "id": "CVE-2018-16333" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-30T00:00:00", "db": "CNVD", "id": "CNVD-2020-35175" }, { "date": "2018-10-25T00:00:00", "db": "VULHUB", "id": "VHN-126682" }, { "date": "2018-10-25T00:00:00", "db": "VULMON", "id": "CVE-2018-16333" }, { "date": "2018-11-19T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-009403" }, { "date": "2018-09-03T00:00:00", "db": "CNNVD", "id": "CNNVD-201809-036" }, { "date": "2024-11-21T03:52:32.530000", "db": "NVD", "id": "CVE-2018-16333" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201809-036" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Tenda Product buffer error vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-009403" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer overflow", "sources": [ { "db": "CNNVD", "id": "CNNVD-201809-036" } ], "trust": 0.6 } }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/ZIllR0/Routers/blob/master/Tenda/oob1.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/ZIllR0/Routers/blob/master/Tenda/oob1.md | Exploit, Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tendacn | ac18_firmware | * | |
tendacn | ac18 | - | |
tendacn | ac15_firmware | 15.03.05.19 | |
tendacn | ac15 | - | |
tendacn | ac10_firmware | 15.03.06.23 | |
tendacn | ac10 | - | |
tendacn | ac9_firmware | 15.03.05.19 | |
tendacn | ac9 | - | |
tendacn | ac7_firmware | 15.03.06.44 | |
tendacn | ac7 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tendacn:ac18_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C1F87AEF-C34D-411D-808F-4A5F60493DA3", "versionEndIncluding": "15.03.05.19", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tendacn:ac18:-:*:*:*:*:*:*:*", "matchCriteriaId": "FCF0F551-6E6C-48D6-9C2A-740B84AF0349", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tendacn:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*", "matchCriteriaId": "7CF021B8-0BA1-42C9-A2A4-4B4BF18F8D4B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tendacn:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "4EEDF33B-0D03-492A-BCD1-0E6B79F783EF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tendacn:ac10_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "C7952445-9298-49B5-9F77-DEF7B18C9483", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tendacn:ac10:-:*:*:*:*:*:*:*", "matchCriteriaId": "0FE0DA72-D225-4BAE-8813-816AB8F0B3FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tendacn:ac9_firmware:15.03.05.19:*:*:*:*:*:*:*", "matchCriteriaId": "5678A346-17EF-4626-BAE4-B1F5C8AFB9CD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tendacn:ac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "E7871810-DC61-4B96-8C3D-2DA1FE202C91", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tendacn:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "82F2488A-65A0-4830-A520-979F8E6ADBB9", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tendacn:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "1D8C8522-F517-4702-828F-D79C803574FF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server. While processing the ssid parameter for a POST request, the value is directly used in a sprintf call to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow." }, { "lang": "es", "value": "Se ha descubierto un problema en dispositivos Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN y AC18 V15.03.05.19(6318)_CN. Hay una vulnerabilidad de desbordamiento de b\u00fafer en el servidor web del router. Al procesar el par\u00e1metro ssid para una petici\u00f3n POST, el valor se emplea directamente en una llamada sprintf a una variable local colocada en la pila, que sobrescribe la direcci\u00f3n de retorno de la funci\u00f3n, provocando un desbordamiento de b\u00fafer." } ], "id": "CVE-2018-16333", "lastModified": "2024-11-21T03:52:32.530", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-09-02T03:29:00.620", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/oob1.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/oob1.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/ZIllR0/Routers/blob/master/Tendaoob1.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/ZIllR0/Routers/blob/master/Tendaoob1.md | Exploit, Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tendacn | ac7_firmware | * | |
tendacn | ac7 | - | |
tendacn | ac9_firmware | * | |
tendacn | ac9 | - | |
tendacn | ac10_firmware | * | |
tendacn | ac10 | - | |
tendacn | ac15_firmware | * | |
tendacn | ac15 | - | |
tendacn | ac18_firmware | * | |
tendacn | ac18 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tendacn:ac7_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7FD0F68A-7B1F-47EA-87A4-534F3076EEB6", "versionEndIncluding": "15.03.06.44_cn", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tendacn:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "1D8C8522-F517-4702-828F-D79C803574FF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tendacn:ac9_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F518F97C-6E41-4488-BC74-A55D00342473", "versionEndIncluding": "v15.03.05.19\\(6318\\)_cn", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tendacn:ac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "E7871810-DC61-4B96-8C3D-2DA1FE202C91", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tendacn:ac10_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5C539B44-DC11-406C-8AEB-30570A1263B1", "versionEndIncluding": "15.03.06.23_cn", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tendacn:ac10:-:*:*:*:*:*:*:*", "matchCriteriaId": "0FE0DA72-D225-4BAE-8813-816AB8F0B3FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tendacn:ac15_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "85FC79AC-BE8A-481E-9782-C000CB45FAC0", "versionEndIncluding": "15.03.05.19_cn", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tendacn:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "4EEDF33B-0D03-492A-BCD1-0E6B79F783EF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tendacn:ac18_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B058E65F-5459-42B1-A5EC-A62635C3751A", "versionEndIncluding": "15.03.05.19\\(6318\\)_cn", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tendacn:ac18:-:*:*:*:*:*:*:*", "matchCriteriaId": "FCF0F551-6E6C-48D6-9C2A-740B84AF0349", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC7 through V15.03.06.44_CN, AC9 through V15.03.05.19(6318)_CN, and AC10 through V15.03.06.23_CN devices have a Stack-based Buffer Overflow via a long limitSpeed or limitSpeedup parameter to an unspecified /goform URI." }, { "lang": "es", "value": "Los dispositivos Tenda AC7 hasta la versi\u00f3n V15.03.06.44_CN, AC9 hasta la versi\u00f3n V15.03.05.19(6318)_CN y AC10 hasta la versi\u00f3n V15.03.06.23_CN tienen un desbordamiento de b\u00fafer basado en pila mediante unos par\u00e1metros limitSpeed o limitSpeedup largos en un URI /goform sin especificar." } ], "id": "CVE-2018-14492", "lastModified": "2024-11-21T03:49:10.740", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-07-21T12:29:00.333", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tendaoob1.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tendaoob1.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
cve-2018-16333
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://github.com/ZIllR0/Routers/blob/master/Tenda/oob1.md | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T10:24:31.599Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/oob1.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-09-01T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server. While processing the ssid parameter for a POST request, the value is directly used in a sprintf call to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-09-02T02:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/oob1.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-16333", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server. While processing the ssid parameter for a POST request, the value is directly used in a sprintf call to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/ZIllR0/Routers/blob/master/Tenda/oob1.md", "refsource": "MISC", "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/oob1.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-16333", "datePublished": "2018-09-02T03:00:00", "dateReserved": "2018-09-01T00:00:00", "dateUpdated": "2024-08-05T10:24:31.599Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-14492
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://github.com/ZIllR0/Routers/blob/master/Tendaoob1.md | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T09:29:51.711Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tendaoob1.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC7 through V15.03.06.44_CN, AC9 through V15.03.05.19(6318)_CN, and AC10 through V15.03.06.23_CN devices have a Stack-based Buffer Overflow via a long limitSpeed or limitSpeedup parameter to an unspecified /goform URI." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-07-21T12:00:00Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tendaoob1.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-14492", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Tenda AC7 through V15.03.06.44_CN, AC9 through V15.03.05.19(6318)_CN, and AC10 through V15.03.06.23_CN devices have a Stack-based Buffer Overflow via a long limitSpeed or limitSpeedup parameter to an unspecified /goform URI." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/ZIllR0/Routers/blob/master/Tendaoob1.md", "refsource": "MISC", "url": "https://github.com/ZIllR0/Routers/blob/master/Tendaoob1.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-14492", "datePublished": "2018-07-21T12:00:00Z", "dateReserved": "2018-07-21T00:00:00Z", "dateUpdated": "2024-09-16T18:18:05.077Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }