Vulnerabilites related to tenda - ac15_firmware
Vulnerability from fkie_nvd
Published
2018-10-29 12:29
Modified
2024-11-21 03:56
Severity ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'startIp' and 'endIp' parameters for a post request, each value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/ZIllR0/Routers/blob/master/Tenda/stack3.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/ZIllR0/Routers/blob/master/Tenda/stack3.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44_cn | |
tenda | ac7 | - | |
tenda | ac9_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac9 | - | |
tenda | ac10_firmware | 15.03.06.23_cn | |
tenda | ac10 | - | |
tenda | ac15_firmware | 15.03.05.19_cn | |
tenda | ac15 | - | |
tenda | ac18_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac18 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44_cn:*:*:*:*:*:*:*", "matchCriteriaId": "EA048307-E3FA-4868-81E2-489CBCD6D27F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "D433B9D2-8F7E-45B7-99EF-50E96B14B324", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23_cn:*:*:*:*:*:*:*", "matchCriteriaId": "39FE2B83-C4C4-4A4B-9F40-A6E340F067A7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*", "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19_cn:*:*:*:*:*:*:*", "matchCriteriaId": "A7FDBF96-9556-4B5C-ADBD-ED5E83557159", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "9AA6A0CA-46AB-4C6F-B4F8-8F3A4D9A71F5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027startIp\u0027 and \u0027endIp\u0027 parameters for a post request, each value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function." }, { "lang": "es", "value": "Se ha descubierto un problema en dispositivos Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN y AC18 V15.03.05.19(6318)_CN. Es una vulnerabilidad de desbordamiento de b\u00fafer en el servidor web del router, httpd. Al procesar los par\u00e1metros startIp y endIp para una petici\u00f3n POST, cada valor se emplea directamente en una llamada sprintf a una variable local colocada en la pila, que sobrescribe la direcci\u00f3n de retorno de la funci\u00f3n." } ], "id": "CVE-2018-18730", "lastModified": "2024-11-21T03:56:28.363", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-10-29T12:29:07.727", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack3.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack3.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2022-11-21 15:15
Modified
2024-11-21 07:27
Severity ?
Summary
Tenda AC15 V15.03.05.18 is avulnerable to Buffer Overflow via function formSetPPTPServer.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://drive.google.com/file/d/1Jq8Tm_2FDS4WDD_afdhg1LnA3VcvZdjS/view?usp=sharing | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://drive.google.com/file/d/1Jq8Tm_2FDS4WDD_afdhg1LnA3VcvZdjS/view?usp=sharing | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.18 | |
tenda | ac15 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*", "matchCriteriaId": "56881C41-A993-45CC-BAE6-E9DE17FA56E2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC15 V15.03.05.18 is avulnerable to Buffer Overflow via function formSetPPTPServer." }, { "lang": "es", "value": "Tenda AC15 V15.03.05.18 es vulnerable al desbordamiento del b\u00fafer mediante la funci\u00f3n formSetPPTPServer." } ], "id": "CVE-2022-44167", "lastModified": "2024-11-21T07:27:40.517", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-11-21T15:15:10.720", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://drive.google.com/file/d/1Jq8Tm_2FDS4WDD_afdhg1LnA3VcvZdjS/view?usp=sharing" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://drive.google.com/file/d/1Jq8Tm_2FDS4WDD_afdhg1LnA3VcvZdjS/view?usp=sharing" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2018-10-29 12:29
Modified
2024-11-21 03:56
Severity ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "page" parameter of the function "fromDhcpListClient" for a request, it is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-06/Tenda.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-06/Tenda.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44_cn | |
tenda | ac7 | - | |
tenda | ac9_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac9 | - | |
tenda | ac10_firmware | 15.03.06.23_cn | |
tenda | ac10 | - | |
tenda | ac15_firmware | 15.03.05.19_cn | |
tenda | ac15 | - | |
tenda | ac18_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac18 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44_cn:*:*:*:*:*:*:*", "matchCriteriaId": "EA048307-E3FA-4868-81E2-489CBCD6D27F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "D433B9D2-8F7E-45B7-99EF-50E96B14B324", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23_cn:*:*:*:*:*:*:*", "matchCriteriaId": "39FE2B83-C4C4-4A4B-9F40-A6E340F067A7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*", "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19_cn:*:*:*:*:*:*:*", "matchCriteriaId": "A7FDBF96-9556-4B5C-ADBD-ED5E83557159", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "9AA6A0CA-46AB-4C6F-B4F8-8F3A4D9A71F5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"page\" parameter of the function \"fromDhcpListClient\" for a request, it is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function." }, { "lang": "es", "value": "Se ha descubierto un problema en dispositivos Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN y AC18 V15.03.05.19(6318)_CN. Es una vulnerabilidad de desbordamiento de b\u00fafer en el servidor web del router, httpd. Al procesar el par\u00e1metro page de la funci\u00f3n fromDhcpListClient para una petici\u00f3n, se emplea directamente en una llamada sprintf a una variable local colocada en la pila, que sobrescribe la direcci\u00f3n de retorno de la funci\u00f3n." } ], "id": "CVE-2018-18706", "lastModified": "2024-11-21T03:56:24.723", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-10-29T12:29:05.400", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-06/Tenda.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-06/Tenda.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2022-09-23 15:15
Modified
2024-11-21 07:22
Severity ?
Summary
Tenda AC15 V15.03.05.19 contained a stack overflow via the function fromAddressNat.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/CPSeek/Router-vuls/blob/main/Tenda/AC15/addressNat.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/CPSeek/Router-vuls/blob/main/Tenda/AC15/addressNat.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.19 | |
tenda | ac15 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*", "matchCriteriaId": "A14A19EE-FB4E-4371-AC85-1401EB78B16D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC15 V15.03.05.19 contained a stack overflow via the function fromAddressNat." }, { "lang": "es", "value": "Tenda AC15 versi\u00f3n V15.03.05.19, contiene un desbordamiento de pila por medio de la funci\u00f3n fromAddressNat." } ], "id": "CVE-2022-40851", "lastModified": "2024-11-21T07:22:09.057", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-09-23T15:15:14.360", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/CPSeek/Router-vuls/blob/main/Tenda/AC15/addressNat.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/CPSeek/Router-vuls/blob/main/Tenda/AC15/addressNat.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-11-01 16:15
Modified
2024-11-05 14:30
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability has been found in Tenda AC15 15.03.05.19 and classified as critical. This vulnerability affects the function SetDlnaCfg of the file /goform/SetDlnaCfg. The manipulation of the argument scanList leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
References
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/theRaz0r/iot-mycve/blob/main/tenda_ac15_stackflow_formDLNAserver/tenda_ac15_stackflow_formDLNAserver.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.282676 | Permissions Required, Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.282676 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.434932 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://www.tenda.com.cn/ | Product |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.19 | |
tenda | ac15 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*", "matchCriteriaId": "A14A19EE-FB4E-4371-AC85-1401EB78B16D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been found in Tenda AC15 15.03.05.19 and classified as critical. This vulnerability affects the function SetDlnaCfg of the file /goform/SetDlnaCfg. The manipulation of the argument scanList leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "es", "value": " Se ha encontrado una vulnerabilidad en Tenda AC15 15.03.05.19 que se ha clasificado como cr\u00edtica. Esta vulnerabilidad afecta a la funci\u00f3n SetDlnaCfg del archivo /goform/SetDlnaCfg. La manipulaci\u00f3n del argumento scanList provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque se puede iniciar de forma remota. El exploit se ha hecho p\u00fablico y puede utilizarse." } ], "id": "CVE-2024-10661", "lastModified": "2024-11-05T14:30:37.787", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "automatable": "NOT_DEFINED", "availabilityRequirements": "NOT_DEFINED", "baseScore": 8.7, "baseSeverity": "HIGH", "confidentialityRequirements": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirements": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubsequentSystemAvailability": "NOT_DEFINED", "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED", "modifiedSubsequentSystemIntegrity": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnerableSystemAvailability": "NOT_DEFINED", "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED", "modifiedVulnerableSystemIntegrity": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "recovery": "NOT_DEFINED", "safety": "NOT_DEFINED", "subsequentSystemAvailability": "NONE", "subsequentSystemConfidentiality": "NONE", "subsequentSystemIntegrity": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnerabilityResponseEffort": "NOT_DEFINED", "vulnerableSystemAvailability": "HIGH", "vulnerableSystemConfidentiality": "HIGH", "vulnerableSystemIntegrity": "HIGH" }, "source": "cna@vuldb.com", "type": "Secondary" } ] }, "published": "2024-11-01T16:15:07.430", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/theRaz0r/iot-mycve/blob/main/tenda_ac15_stackflow_formDLNAserver/tenda_ac15_stackflow_formDLNAserver.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.282676" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.282676" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.434932" }, { "source": "cna@vuldb.com", "tags": [ "Product" ], "url": "https://www.tenda.com.cn/" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2022-10-18 15:15
Modified
2024-11-21 07:26
Severity ?
Summary
Tenda AC15 V15.03.05.18 was discovered to contain a stack overflow via the timeZone parameter in the form_fast_setting_wifi_set function.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://drive.google.com/file/d/1VjYjZKv7MJ69hGPG-xD0xublUw-taq4w/view?usp=sharing | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://drive.google.com/file/d/1VjYjZKv7MJ69hGPG-xD0xublUw-taq4w/view?usp=sharing | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.18 | |
tenda | ac15_firmware | 15.03.05.19 | |
tenda | ac15 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*", "matchCriteriaId": "56881C41-A993-45CC-BAE6-E9DE17FA56E2", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*", "matchCriteriaId": "A14A19EE-FB4E-4371-AC85-1401EB78B16D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC15 V15.03.05.18 was discovered to contain a stack overflow via the timeZone parameter in the form_fast_setting_wifi_set function." }, { "lang": "es", "value": "Se ha detectado que Tenda AC15 versi\u00f3n V15.03.05.18, contiene un desbordamiento de pila por medio del par\u00e1metro timeZone en la funci\u00f3n form_fast_setting_wifi_set" } ], "id": "CVE-2022-43259", "lastModified": "2024-11-21T07:26:09.273", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-10-18T15:15:10.390", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://drive.google.com/file/d/1VjYjZKv7MJ69hGPG-xD0xublUw-taq4w/view?usp=sharing" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://drive.google.com/file/d/1VjYjZKv7MJ69hGPG-xD0xublUw-taq4w/view?usp=sharing" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-07-13 18:15
Modified
2024-11-21 04:56
Severity ?
Summary
A CSRF issue in the /goform/SysToolReboot endpoint of Tenda AC15 AC1900 version 15.03.05.19 allows remote attackers to reboot the device and cause denial of service via a payload hosted by an attacker-controlled web page.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68 | Exploit, Third Party Advisory | |
cve@mitre.org | https://www.ise.io/research/ | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68 | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.ise.io/research/ | Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.19 | |
tenda | ac15 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*", "matchCriteriaId": "A14A19EE-FB4E-4371-AC85-1401EB78B16D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A CSRF issue in the /goform/SysToolReboot endpoint of Tenda AC15 AC1900 version 15.03.05.19 allows remote attackers to reboot the device and cause denial of service via a payload hosted by an attacker-controlled web page." }, { "lang": "es", "value": "Un problema de tipo CSRF en el endpoint /goform/SysToolReboot de Tenda AC15 AC1900 versi\u00f3n 15.03.05.19, permite a atacantes remotos reiniciar el dispositivo y causar una denegaci\u00f3n de servicio por medio de una carga \u00fatil alojada por una p\u00e1gina web controlada por un atacante" } ], "id": "CVE-2020-10986", "lastModified": "2024-11-21T04:56:31.320", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.1, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-07-13T18:15:11.170", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68" }, { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://www.ise.io/research/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://www.ise.io/research/" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-352" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-07-13 19:15
Modified
2025-02-04 20:15
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
The goform/setUsbUnload endpoint of Tenda AC15 AC1900 version 15.03.05.19 allows remote attackers to execute arbitrary system commands via the deviceName POST parameter.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68 | Exploit, Third Party Advisory | |
cve@mitre.org | https://www.ise.io/research/ | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68 | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.ise.io/research/ | Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.19 | |
tenda | ac15 | - |
{ "cisaActionDue": "2022-05-03", "cisaExploitAdd": "2021-11-03", "cisaRequiredAction": "Apply updates per vendor instructions.", "cisaVulnerabilityName": "Tenda AC1900 Router AC15 Model Remote Code Execution Vulnerability", "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*", "matchCriteriaId": "A14A19EE-FB4E-4371-AC85-1401EB78B16D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "The goform/setUsbUnload endpoint of Tenda AC15 AC1900 version 15.03.05.19 allows remote attackers to execute arbitrary system commands via the deviceName POST parameter." }, { "lang": "es", "value": "El endpoint goform/setUsbUnload de Tenda AC15 AC1900 versi\u00f3n 15.03.05.19, permite a atacantes remotos ejecutar comandos del sistema arbitrarios por medio del par\u00e1metro POST deviceName" } ], "id": "CVE-2020-10987", "lastModified": "2025-02-04T20:15:34.827", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2020-07-13T19:15:12.207", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68" }, { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://www.ise.io/research/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://www.ise.io/research/" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2022-11-21 15:15
Modified
2024-11-21 07:27
Severity ?
Summary
Tenda AC15 V15.03.05.18 is vulnerable to Buffer Overflow via function fromSetRouteStatic..
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/RobinWang825/IoT_vuln/tree/main/Tenda/AC15/fromSetRouteStatic | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/RobinWang825/IoT_vuln/tree/main/Tenda/AC15/fromSetRouteStatic | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.18 | |
tenda | ac15 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*", "matchCriteriaId": "56881C41-A993-45CC-BAE6-E9DE17FA56E2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC15 V15.03.05.18 is vulnerable to Buffer Overflow via function fromSetRouteStatic.." }, { "lang": "es", "value": "Tenda AC15 V15.03.05.18 es vulnerable al desbordamiento del b\u00fafer mediante la funci\u00f3n fromSetRouteStatic." } ], "id": "CVE-2022-44168", "lastModified": "2024-11-21T07:27:40.727", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-11-21T15:15:10.857", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/RobinWang825/IoT_vuln/tree/main/Tenda/AC15/fromSetRouteStatic" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/RobinWang825/IoT_vuln/tree/main/Tenda/AC15/fromSetRouteStatic" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-07-23 18:15
Modified
2024-11-21 05:06
Severity ?
Summary
goform/AdvSetLanip endpoint on Tenda AC15 AC1900 15.03.05.19 devices allows remote attackers to execute arbitrary system commands via shell metacharacters in the lanIp POST parameter.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68 | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68 | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.19 | |
tenda | ac15 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*", "matchCriteriaId": "A14A19EE-FB4E-4371-AC85-1401EB78B16D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "goform/AdvSetLanip endpoint on Tenda AC15 AC1900 15.03.05.19 devices allows remote attackers to execute arbitrary system commands via shell metacharacters in the lanIp POST parameter." }, { "lang": "es", "value": "El endpoint goform/AdvSetLanip en los dispositivos Tenda AC15 AC1900 versiones 15.03.05.19, permite a atacantes remotos ejecutar comandos arbitrarios del sistema por medio de metacaracteres de shell en el par\u00e1metro lanIp POST" } ], "id": "CVE-2020-15916", "lastModified": "2024-11-21T05:06:26.530", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-07-23T18:15:11.763", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2022-11-21 15:15
Modified
2024-11-21 07:27
Severity ?
Summary
Tenda AC15 V15.03.05.18 is vulnerable to Buffer Overflow via function formSetVirtualSer.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/RobinWang825/IoT_vuln/tree/main/Tenda/AC15/formSetVirtualSer | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/RobinWang825/IoT_vuln/tree/main/Tenda/AC15/formSetVirtualSer | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.18 | |
tenda | ac15 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*", "matchCriteriaId": "56881C41-A993-45CC-BAE6-E9DE17FA56E2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC15 V15.03.05.18 is vulnerable to Buffer Overflow via function formSetVirtualSer." }, { "lang": "es", "value": "Tenda AC15 V15.03.05.18 es vulnerable al desbordamiento del b\u00fafer a trav\u00e9s de la funci\u00f3n formSetVirtualSer." } ], "id": "CVE-2022-44169", "lastModified": "2024-11-21T07:27:41.317", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-11-21T15:15:11.150", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/RobinWang825/IoT_vuln/tree/main/Tenda/AC15/formSetVirtualSer" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/RobinWang825/IoT_vuln/tree/main/Tenda/AC15/formSetVirtualSer" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-22 05:15
Modified
2024-11-21 09:10
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.20_multi. This vulnerability affects the function formExpandDlnaFile of the file /goform/expandDlnaFile. The manipulation of the argument filePath leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257662 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formExpandDlnaFile.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.257662 | Permissions Required | |
cna@vuldb.com | https://vuldb.com/?id.257662 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formExpandDlnaFile.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.257662 | Permissions Required | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.257662 | Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.18 | |
tenda | ac15_firmware | 15.03.05.20_multi | |
tenda | ac15 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*", "matchCriteriaId": "56881C41-A993-45CC-BAE6-E9DE17FA56E2", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.20_multi:*:*:*:*:*:*:*", "matchCriteriaId": "BAF4BBA3-7C56-4383-B167-933075D5C39F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D5059CAD-BD1A-4808-BCED-006444E60701", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.20_multi. This vulnerability affects the function formExpandDlnaFile of the file /goform/expandDlnaFile. The manipulation of the argument filePath leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257662 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Una vulnerabilidad fue encontrada en Tenda AC15 15.03.05.18/15.03.20_multi y clasificada como cr\u00edtica. Esta vulnerabilidad afecta a la funci\u00f3n formExpandDlnaFile del archivo /goform/expandDlnaFile. La manipulaci\u00f3n del argumento filePath conduce a un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque se puede iniciar de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. VDB-257662 es el identificador asignado a esta vulnerabilidad. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-2807", "lastModified": "2024-11-21T09:10:34.117", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-22T05:15:48.807", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formExpandDlnaFile.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.257662" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.257662" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formExpandDlnaFile.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.257662" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.257662" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-24 02:15
Modified
2024-11-21 09:10
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability was found in Tenda AC15 15.03.05.18 and classified as critical. Affected by this issue is the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257774 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/saveParentControlInfo_urls.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.257774 | Permissions Required | |
cna@vuldb.com | https://vuldb.com/?id.257774 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/saveParentControlInfo_urls.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.257774 | Permissions Required | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.257774 | Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.18 | |
tenda | ac15 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*", "matchCriteriaId": "56881C41-A993-45CC-BAE6-E9DE17FA56E2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC15 15.03.05.18 and classified as critical. Affected by this issue is the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257774 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Una vulnerabilidad fue encontrada en Tenda AC15 15.03.05.18 y clasificada como cr\u00edtica. La funci\u00f3n saveParentControlInfo del archivo /goform/saveParentControlInfo es afectada por esta vulnerabilidad. La manipulaci\u00f3n de las URL de argumentos conduce a un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque puede lanzarse de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. VDB-257774 es el identificador asignado a esta vulnerabilidad. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-2850", "lastModified": "2024-11-21T09:10:40.440", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-24T02:15:07.517", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/saveParentControlInfo_urls.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.257774" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.257774" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/saveParentControlInfo_urls.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.257774" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.257774" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2017-11-24 07:29
Modified
2024-11-21 03:17
Severity ?
Summary
Directory Traversal vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to read arbitrary files via a cgi-bin/luci/request?op=1&path= URI that uses directory traversal sequences after a /usb/ substring.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/Iolop/Poc/tree/master/Router/Tenda | Issue Tracking, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/Iolop/Poc/tree/master/Router/Tenda | Issue Tracking, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac9_firmware | us_ac9v1.0br_v15.03.05.14_multi_td01 | |
tenda | ac9 | - | |
tenda | ac9_firmware | ac9_kf_v15.03.05.19\(6318_\)_cn | |
tenda | ac9 | - | |
tenda | ac15_firmware | us_ac15v1.0br_v15.03.05.18_multi_td01 | |
tenda | ac15 | - | |
tenda | ac15_firmware | us_ac15v1.0br_v15.03.05.19_multi_td01 | |
tenda | ac15 | - | |
tenda | ac18_firmware | us_ac18v1.0br_v15.03.05.05_multi_td01 | |
tenda | ac18 | - | |
tenda | ac18_firmware | ac18_kf_v15.03.05.19\(6318_\)_cn | |
tenda | ac18 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:us_ac9v1.0br_v15.03.05.14_multi_td01:*:*:*:*:*:*:*", "matchCriteriaId": "A892AC99-F24B-4E0F-B3F0-CDBE1F4AD446", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:ac9_kf_v15.03.05.19\\(6318_\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "512EB7D7-B12E-4219-8270-9EFCC8F6F366", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:us_ac15v1.0br_v15.03.05.18_multi_td01:*:*:*:*:*:*:*", "matchCriteriaId": "6A51B455-6ABD-4827-B948-7341D353C05E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:us_ac15v1.0br_v15.03.05.19_multi_td01:*:*:*:*:*:*:*", "matchCriteriaId": "9535D5AC-FCE6-40A9-BA55-10DFE110BBBC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac18_firmware:us_ac18v1.0br_v15.03.05.05_multi_td01:*:*:*:*:*:*:*", "matchCriteriaId": "35D8463B-CC09-4C38-9881-4D7E3EC2B635", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac18_firmware:ac18_kf_v15.03.05.19\\(6318_\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "72C6CF57-11B7-4A11-AA61-248ACAFE624C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Directory Traversal vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to read arbitrary files via a cgi-bin/luci/request?op=1\u0026path= URI that uses directory traversal sequences after a /usb/ substring." }, { "lang": "es", "value": "Una vulnerabilidad de salto de directorio en app_data_center en dispositivos Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01 y Ac18 ac18_kf_V15.03.05.19(6318_)_cn permite que atacantes remotos no autenticados lean archivos arbitrarios mediante un URI cgi-bin/luci/request?op=1path= que emplea secuencias de salto de directorio tras una subcadena /usb/." } ], "id": "CVE-2017-16936", "lastModified": "2024-11-21T03:17:16.710", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2017-11-24T07:29:00.350", "references": [ { "source": "cve@mitre.org", "tags": [ "Issue Tracking", "Third Party Advisory" ], "url": "https://github.com/Iolop/Poc/tree/master/Router/Tenda" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Issue Tracking", "Third Party Advisory" ], "url": "https://github.com/Iolop/Poc/tree/master/Router/Tenda" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-22" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-22 07:15
Modified
2024-11-21 09:10
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability was found in Tenda AC15 15.03.20_multi. It has been rated as critical. This issue affects the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257669 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/fromDhcpListClient_page.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.257669 | Permissions Required | |
cna@vuldb.com | https://vuldb.com/?id.257669 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/fromDhcpListClient_page.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.257669 | Permissions Required | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.257669 | Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.20_multi | |
tenda | ac15 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.20_multi:*:*:*:*:*:*:*", "matchCriteriaId": "BAF4BBA3-7C56-4383-B167-933075D5C39F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC15 15.03.20_multi. It has been rated as critical. This issue affects the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257669 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Se encontr\u00f3 una vulnerabilidad en Tenda AC15 15.03.20_multi. Ha sido calificada como cr\u00edtica. Este problema afecta la funci\u00f3n fromDhcpListClient del archivo /goform/DhcpListClient. La manipulaci\u00f3n de la p\u00e1gina de argumentos provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque puede iniciarse de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. A esta vulnerabilidad se le asign\u00f3 el identificador VDB-257669. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-2814", "lastModified": "2024-11-21T09:10:35.307", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-22T07:15:47.447", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/fromDhcpListClient_page.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.257669" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.257669" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/fromDhcpListClient_page.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.257669" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.257669" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "NVD-CWE-Other" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2018-10-29 12:29
Modified
2024-11-21 03:56
Severity ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "ssid" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-07/Tenda.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-07/Tenda.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44_cn | |
tenda | ac7 | - | |
tenda | ac9_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac9 | - | |
tenda | ac10_firmware | 15.03.06.23_cn | |
tenda | ac10 | - | |
tenda | ac15_firmware | 15.03.05.19_cn | |
tenda | ac15 | - | |
tenda | ac18_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac18 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44_cn:*:*:*:*:*:*:*", "matchCriteriaId": "EA048307-E3FA-4868-81E2-489CBCD6D27F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "D433B9D2-8F7E-45B7-99EF-50E96B14B324", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23_cn:*:*:*:*:*:*:*", "matchCriteriaId": "39FE2B83-C4C4-4A4B-9F40-A6E340F067A7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*", "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19_cn:*:*:*:*:*:*:*", "matchCriteriaId": "A7FDBF96-9556-4B5C-ADBD-ED5E83557159", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "9AA6A0CA-46AB-4C6F-B4F8-8F3A4D9A71F5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"ssid\" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function." }, { "lang": "es", "value": "Se ha descubierto un problema en dispositivos Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN y AC18 V15.03.05.19(6318)_CN. Es una vulnerabilidad de desbordamiento de b\u00fafer en el servidor web del router, httpd. Al procesar el par\u00e1metro ssid para una petici\u00f3n POST, el valor se emplea directamente en una llamada strcpy a una variable local colocada en la pila, que sobrescribe la direcci\u00f3n de retorno de la funci\u00f3n." } ], "id": "CVE-2018-18707", "lastModified": "2024-11-21T03:56:24.870", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-10-29T12:29:05.507", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-07/Tenda.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-07/Tenda.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-09-10 16:15
Modified
2024-09-24 18:10
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
8.0 (High) - CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.0 (High) - CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
Command Injection vulnerability in goform/SetIPTVCfg interface of Tenda AC15 V15.03.05.20 allows remote attackers to run arbitrary commands via crafted POST request.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/t0hka1/Tenda-AC15-Exp/blob/master/Tenda%20AC15%20V15.03.05.20%20Exp.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.20 | |
tenda | ac15 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.20:*:*:*:*:*:*:*", "matchCriteriaId": "35964FEE-C449-4967-A6B6-7A0CDC1DD3FA", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Command Injection vulnerability in goform/SetIPTVCfg interface of Tenda AC15 V15.03.05.20 allows remote attackers to run arbitrary commands via crafted POST request." }, { "lang": "es", "value": "La vulnerabilidad de inyecci\u00f3n de comandos en la interfaz goform/SetIPTVCfg de Tenda AC15 V15.03.05.20 permite a atacantes remotos ejecutar comandos arbitrarios a trav\u00e9s de una solicitud POST manipulada." } ], "id": "CVE-2023-36103", "lastModified": "2024-09-24T18:10:16.207", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.0, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.1, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2024-09-10T16:15:18.380", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/t0hka1/Tenda-AC15-Exp/blob/master/Tenda%20AC15%20V15.03.05.20%20Exp.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2023-08-18 03:15
Modified
2024-11-21 08:15
Severity ?
Summary
Tenda AC15 V1.0BR_V15.03.05.18_multi_TD01 was discovered to contain a buffer overflow via the function FUN_00010e34().
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.18 | |
tenda | ac15 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*", "matchCriteriaId": "56881C41-A993-45CC-BAE6-E9DE17FA56E2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D5059CAD-BD1A-4808-BCED-006444E60701", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC15 V1.0BR_V15.03.05.18_multi_TD01 was discovered to contain a buffer overflow via the function FUN_00010e34()." }, { "lang": "es", "value": "Se ha descubierto que Tenda AC15 V1.0BR_V15.03.05.18_multi_TD01 contiene un desbordamiento de b\u00fafer a trav\u00e9s de la funci\u00f3n FUN_00010e34()." } ], "id": "CVE-2023-39673", "lastModified": "2024-11-21T08:15:48.683", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-18T03:15:24.247", "references": [ { "source": "cve@mitre.org", "tags": [ "Broken Link" ], "url": "https://github.com/Davidteeri/Bug-Report/blob/main/Tenda/AC15%20Impoper%20Input%20Validation.md" }, { "source": "cve@mitre.org", "tags": [ "Product" ], "url": "https://www.tendacn.com/download/list-3.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link" ], "url": "https://github.com/Davidteeri/Bug-Report/blob/main/Tenda/AC15%20Impoper%20Input%20Validation.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Product" ], "url": "https://www.tendacn.com/download/list-3.html" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-07-13 19:15
Modified
2024-11-21 04:56
Severity ?
Summary
An XSS issue in the /goform/WifiBasicSet endpoint of Tenda AC15 AC1900 version 15.03.05.19 allows remote attackers to execute malicious payloads via the WifiName POST parameter.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68 | Exploit, Third Party Advisory | |
cve@mitre.org | https://www.ise.io/research/ | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68 | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.ise.io/research/ | Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.19 | |
tenda | ac15 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*", "matchCriteriaId": "A14A19EE-FB4E-4371-AC85-1401EB78B16D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An XSS issue in the /goform/WifiBasicSet endpoint of Tenda AC15 AC1900 version 15.03.05.19 allows remote attackers to execute malicious payloads via the WifiName POST parameter." }, { "lang": "es", "value": "Un problema de tipo XSS en el endpoint /goform/WifiBasicSet de Tenda AC15 AC1900 versi\u00f3n 15.03.05.19, permite a atacantes remotos ejecutar cargas maliciosas por medio del par\u00e1metro POST WifiName" } ], "id": "CVE-2020-10989", "lastModified": "2024-11-21T04:56:31.787", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-07-13T19:15:12.347", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68" }, { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://www.ise.io/research/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://www.ise.io/research/" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-04-24 15:15
Modified
2025-02-05 16:15
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
In Tenda AC15 V15.03.05.19, the function "sub_8EE8" contains a stack-based buffer overflow vulnerability.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/2205794866/Tenda/blob/main/AC15/5.md | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/2205794866/Tenda/blob/main/AC15/5.md | Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.19 | |
tenda | ac15 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*", "matchCriteriaId": "A14A19EE-FB4E-4371-AC85-1401EB78B16D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "In Tenda AC15 V15.03.05.19, the function \"sub_8EE8\" contains a stack-based buffer overflow vulnerability." } ], "id": "CVE-2023-30378", "lastModified": "2025-02-05T16:15:39.213", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2023-04-24T15:15:09.223", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://github.com/2205794866/Tenda/blob/main/AC15/5.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://github.com/2205794866/Tenda/blob/main/AC15/5.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2018-10-29 12:29
Modified
2024-11-21 03:56
Severity ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "firewallEn" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-08/Tenda.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-08/Tenda.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44_cn | |
tenda | ac7 | - | |
tenda | ac9_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac9 | - | |
tenda | ac10_firmware | 15.03.06.23_cn | |
tenda | ac10 | - | |
tenda | ac15_firmware | 15.03.05.19_cn | |
tenda | ac15 | - | |
tenda | ac18_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac18 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44_cn:*:*:*:*:*:*:*", "matchCriteriaId": "EA048307-E3FA-4868-81E2-489CBCD6D27F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "D433B9D2-8F7E-45B7-99EF-50E96B14B324", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23_cn:*:*:*:*:*:*:*", "matchCriteriaId": "39FE2B83-C4C4-4A4B-9F40-A6E340F067A7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*", "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19_cn:*:*:*:*:*:*:*", "matchCriteriaId": "A7FDBF96-9556-4B5C-ADBD-ED5E83557159", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "9AA6A0CA-46AB-4C6F-B4F8-8F3A4D9A71F5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"firewallEn\" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function." }, { "lang": "es", "value": "Se ha descubierto un problema en dispositivos Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN y AC18 V15.03.05.19(6318)_CN. Es una vulnerabilidad de desbordamiento de b\u00fafer en el servidor web del router, httpd. Al procesar el par\u00e1metro firewallEn para una petici\u00f3n POST, el valor se emplea directamente en una llamada strcpy a una variable local colocada en la pila, que sobrescribe la direcci\u00f3n de retorno de la funci\u00f3n." } ], "id": "CVE-2018-18709", "lastModified": "2024-11-21T03:56:25.177", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-10-29T12:29:05.727", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-08/Tenda.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-08/Tenda.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-10-23 14:15
Modified
2024-11-01 14:03
Severity ?
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
References
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/JohenanLi/router_vuls/blob/main/websReadEvent/websReadEvent.md | Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.281555 | Permissions Required, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.281555 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.426417 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://www.tenda.com.cn/ | Product |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.18 | |
tenda | ac15_firmware | 15.03.05.19 | |
tenda | ac15 | - | |
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | - | |
tenda | ac10u_firmware | 15.03.06.48 | |
tenda | ac10u_firmware | 15.03.06.49 | |
tenda | ac10u | - | |
tenda | ac500_firmware | 1.0.0.14 | |
tenda | ac500_firmware | 1.0.0.16 | |
tenda | ac500_firmware | 2.0.1.9\(1307\) | |
tenda | ac500 | - | |
tenda | ac18_firmware | 15.03.05.05 | |
tenda | ac18_firmware | 15.03.05.19\(6318\) | |
tenda | ac18 | - | |
tenda | ac9_firmware | 15.03.2.13 | |
tenda | ac9_firmware | 15.03.05.14 | |
tenda | ac9_firmware | 15.03.05.19\(6318\) | |
tenda | ac9 | 1.0 | |
tenda | ac9_firmware | 15.03.06.42 | |
tenda | ac9 | 3.0 | |
tenda | ac1206_firmware | 15.03.06.23 | |
tenda | ac1206 | - | |
tenda | ac6_firmware | 15.03.06.23 | |
tenda | ac6 | 2.0 | |
tenda | ac10_firmware | 16.03.10.13 | |
tenda | ac10_firmware | 16.03.10.20 | |
tenda | ac10 | 4.0 | |
tenda | ac10_firmware | 16.03.48.19 | |
tenda | ac10_firmware | 16.03.48.23 | |
tenda | ac10 | 5.0 | |
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8_firmware | 16.03.34.09 | |
tenda | ac8 | 4.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*", "matchCriteriaId": "56881C41-A993-45CC-BAE6-E9DE17FA56E2", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*", "matchCriteriaId": "A14A19EE-FB4E-4371-AC85-1401EB78B16D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.48:*:*:*:*:*:*:*", "matchCriteriaId": "1C2AFD04-833D-4085-BAD6-32A2715FA785", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*", "matchCriteriaId": "0F101E88-BEA9-4017-9048-860DF3D1BBBC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10u:-:*:*:*:*:*:*:*", "matchCriteriaId": "CDBE5E26-7967-4FDD-A29F-7740B29C4B8E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac500_firmware:1.0.0.14:*:*:*:*:*:*:*", "matchCriteriaId": "61BA4026-93A8-4D83-815E-397A2EC0A279", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac500_firmware:1.0.0.16:*:*:*:*:*:*:*", "matchCriteriaId": "816A7A37-5952-4B22-80F7-8CD09383E079", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*", "matchCriteriaId": "2F0EEFAB-B3B0-4C10-A712-7A35F5FD076E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*", "matchCriteriaId": "64192A8B-CC65-44EC-942B-CC16AADF0D69", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*", "matchCriteriaId": "4D5CB727-FC6B-4212-A61E-2888A0DADFB0", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\):*:*:*:*:*:*:*", "matchCriteriaId": "3AC468E5-44D1-4B94-B308-C1025DB1BB7B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.2.13:*:*:*:*:*:*:*", "matchCriteriaId": "3473D6FD-4D42-46D0-9D96-F95D6D856E8E", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.14:*:*:*:*:*:*:*", "matchCriteriaId": "DA7503C5-02C6-4016-A4C6-414146719BFF", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\):*:*:*:*:*:*:*", "matchCriteriaId": "D8F25141-8B57-463D-AB97-F52C0143973C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "566DA530-18FC-4A46-95B4-2A7D343A96A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42:*:*:*:*:*:*:*", "matchCriteriaId": "5B0A5168-9E0C-43F7-BF7B-3943A3316CB8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*", "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "787A50A1-EDBC-44EB-8CF2-11C4FC63719D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*", "matchCriteriaId": "29D5013D-520A-461A-95FF-43B2BE160F91", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "D82FD30C-AF3C-4E3B-B674-002A5C9ED09D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac6:2.0:*:*:*:*:*:*:*", "matchCriteriaId": "E382AD7E-1450-40FC-AE9D-698B491805F0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*", "matchCriteriaId": "6F1C8715-D7B4-4D1A-9E90-079C72049332", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac10_firmware:16.03.10.20:*:*:*:*:*:*:*", "matchCriteriaId": "A19C486B-52A3-4C3E-851D-F349E8E0A706", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "970AEBF4-2B32-4633-A75B-2D2C598C048D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:16.03.48.19:*:*:*:*:*:*:*", "matchCriteriaId": "DABA74C0-297A-4372-B84D-00BA0D334318", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac10_firmware:16.03.48.23:*:*:*:*:*:*:*", "matchCriteriaId": "AC3020CA-7422-4B9A-AA7B-C2B1A03A4450", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:5.0:*:*:*:*:*:*:*", "matchCriteriaId": "2BCFFBD6-3DAD-4FEA-9B5D-D7CBFC36572D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.09:*:*:*:*:*:*:*", "matchCriteriaId": "EE69F412-6FC7-470D-BC7E-B3AAC6B4585F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "655619B2-6E8B-4D2E-98E7-028E69597E80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "es", "value": "Se ha detectado una vulnerabilidad en Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 y AC1206 hasta 20241022. Se ha calificado como problem\u00e1tica. Este problema afecta a la funci\u00f3n websReadEvent del archivo /goform/GetIPTV. La manipulaci\u00f3n del argumento Content-Length provoca la desreferenciaci\u00f3n de puntero nulo. El ataque puede iniciarse de forma remota. El exploit se ha hecho p\u00fablico y puede utilizarse." } ], "id": "CVE-2024-10280", "lastModified": "2024-11-01T14:03:20.267", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 6.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "automatable": "NOT_DEFINED", "availabilityRequirements": "NOT_DEFINED", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityRequirements": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirements": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubsequentSystemAvailability": "NOT_DEFINED", "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED", "modifiedSubsequentSystemIntegrity": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnerableSystemAvailability": "NOT_DEFINED", "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED", "modifiedVulnerableSystemIntegrity": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "recovery": "NOT_DEFINED", "safety": "NOT_DEFINED", "subsequentSystemAvailability": "NONE", "subsequentSystemConfidentiality": "NONE", "subsequentSystemIntegrity": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnerabilityResponseEffort": "NOT_DEFINED", "vulnerableSystemAvailability": "HIGH", "vulnerableSystemConfidentiality": "NONE", "vulnerableSystemIntegrity": "NONE" }, "source": "cna@vuldb.com", "type": "Secondary" } ] }, "published": "2024-10-23T14:15:04.500", "references": [ { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory" ], "url": "https://github.com/JohenanLi/router_vuls/blob/main/websReadEvent/websReadEvent.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.281555" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.281555" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.426417" }, { "source": "cna@vuldb.com", "tags": [ "Product" ], "url": "https://www.tenda.com.cn/" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-476" } ], "source": "cna@vuldb.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-04-24 15:15
Modified
2025-02-05 16:15
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
In Tenda AC15 V15.03.05.19, the function "henan_pppoe_user" contains a stack-based buffer overflow vulnerability.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/2205794866/Tenda/blob/main/AC15/9.md | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/2205794866/Tenda/blob/main/AC15/9.md | Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.19 | |
tenda | ac15 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*", "matchCriteriaId": "A14A19EE-FB4E-4371-AC85-1401EB78B16D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "In Tenda AC15 V15.03.05.19, the function \"henan_pppoe_user\" contains a stack-based buffer overflow vulnerability." } ], "id": "CVE-2023-30376", "lastModified": "2025-02-05T16:15:39.070", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2023-04-24T15:15:09.180", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://github.com/2205794866/Tenda/blob/main/AC15/9.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://github.com/2205794866/Tenda/blob/main/AC15/9.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2022-05-04 16:15
Modified
2024-11-21 06:57
Severity ?
Summary
There is a command injection vulnerability at the /goform/setsambacfg interface of Tenda AC15 US_AC15V1.0BR_V15.03.05.20_multi_TDE01.bin device web, which can also cooperate with CVE-2021-44971 to cause unconditional arbitrary command execution
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/doudoudedi/TendaAC15_vul/blob/main/TendaAC15-vul.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/doudoudedi/TendaAC15_vul/blob/main/TendaAC15-vul.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.20_multi_tde01 | |
tenda | ac15 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.20_multi_tde01:*:*:*:*:*:*:*", "matchCriteriaId": "B9C2B371-287E-4062-BC68-EFBE4D5DC908", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D5059CAD-BD1A-4808-BCED-006444E60701", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "There is a command injection vulnerability at the /goform/setsambacfg interface of Tenda AC15 US_AC15V1.0BR_V15.03.05.20_multi_TDE01.bin device web, which can also cooperate with CVE-2021-44971 to cause unconditional arbitrary command execution" }, { "lang": "es", "value": "Se presenta una vulnerabilidad de inyecci\u00f3n de comandos en la interfaz /goform/setsambacfg de la web del dispositivo Tenda AC15 versi\u00f3n US_AC15V1.0BR_V15.03.05.20_multi_TDE01.bin, que tambi\u00e9n puede cooperar con CVE-2021-44971 para causar una ejecuci\u00f3n de comandos arbitrarios incondicionales" } ], "id": "CVE-2022-28557", "lastModified": "2024-11-21T06:57:30.793", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-05-04T16:15:08.697", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/doudoudedi/TendaAC15_vul/blob/main/TendaAC15-vul.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/doudoudedi/TendaAC15_vul/blob/main/TendaAC15-vul.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-22 03:15
Modified
2025-01-24 18:45
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been rated as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257660. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/SetSpeedWan.md | Broken Link, Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.257660 | Permissions Required, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.257660 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/SetSpeedWan.md | Broken Link, Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.257660 | Permissions Required, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.257660 | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.18 | |
tenda | ac15_firmware | 15.03.05.20_multi | |
tenda | ac15 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*", "matchCriteriaId": "56881C41-A993-45CC-BAE6-E9DE17FA56E2", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.20_multi:*:*:*:*:*:*:*", "matchCriteriaId": "BAF4BBA3-7C56-4383-B167-933075D5C39F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been rated as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257660. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Se encontr\u00f3 una vulnerabilidad en Tenda AC15 15.03.05.18/15.03.20_multi. Ha sido calificada como cr\u00edtica. La funci\u00f3n formSetSpeedWan del archivo /goform/SetSpeedWan es afectada por esta vulnerabilidad. La manipulaci\u00f3n del argumento speed_dir provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque puede lanzarse de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. El identificador de esta vulnerabilidad es VDB-257660. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-2805", "lastModified": "2025-01-24T18:45:05.873", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-22T03:15:08.130", "references": [ { "source": "cna@vuldb.com", "tags": [ "Broken Link", "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/SetSpeedWan.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.257660" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.257660" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link", "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/SetSpeedWan.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.257660" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.257660" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2022-05-04 16:15
Modified
2024-11-21 06:57
Severity ?
Summary
Tenda AC15 US_AC15V1.0BR_V15.03.05.20_multi_TDE01.bin is vulnerable to Buffer Overflow. The stack overflow vulnerability lies in the /goform/setpptpservercfg interface of the web. The sent post data startip and endip are copied to the stack using the sanf function, resulting in stack overflow. Similarly, this vulnerability can be used together with CVE-2021-44971
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/doudoudedi/TendaAC15_vul/blob/main/TendaAC15-vul.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/doudoudedi/TendaAC15_vul/blob/main/TendaAC15-vul.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.20_multi_tde01 | |
tenda | ac15 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.20_multi_tde01:*:*:*:*:*:*:*", "matchCriteriaId": "B9C2B371-287E-4062-BC68-EFBE4D5DC908", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D5059CAD-BD1A-4808-BCED-006444E60701", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC15 US_AC15V1.0BR_V15.03.05.20_multi_TDE01.bin is vulnerable to Buffer Overflow. The stack overflow vulnerability lies in the /goform/setpptpservercfg interface of the web. The sent post data startip and endip are copied to the stack using the sanf function, resulting in stack overflow. Similarly, this vulnerability can be used together with CVE-2021-44971" }, { "lang": "es", "value": "Tenda AC15 versi\u00f3n US_AC15V1.0BR_V15.03.05.20_multi_TDE01.bin, es vulnerable a un desbordamiento del b\u00fafer. La vulnerabilidad de desbordamiento de pila se encuentra en la interfaz /goform/setpptpservercfg de la web. Los datos post enviados startip y endip son copiados a la pila usando la funci\u00f3n sanf, resultando en un desbordamiento de pila. Del mismo modo, esta vulnerabilidad puede usarse junto con CVE-2021-44971" } ], "id": "CVE-2022-28556", "lastModified": "2024-11-21T06:57:30.647", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-05-04T16:15:08.647", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/doudoudedi/TendaAC15_vul/blob/main/TendaAC15-vul.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/doudoudedi/TendaAC15_vul/blob/main/TendaAC15-vul.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-04-24 15:15
Modified
2025-02-04 21:15
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
In Tenda AC15 V15.03.05.19, the function GetValue contains a stack-based buffer overflow vulnerability.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.19 | |
tenda | ac15 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*", "matchCriteriaId": "A14A19EE-FB4E-4371-AC85-1401EB78B16D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "In Tenda AC15 V15.03.05.19, the function GetValue contains a stack-based buffer overflow vulnerability." } ], "id": "CVE-2023-30370", "lastModified": "2025-02-04T21:15:24.913", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2023-04-24T15:15:08.967", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://github.com/2205794866/Tenda/blob/main/AC15/7.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://github.com/2205794866/Tenda/blob/main/AC15/7.md" }, { "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "url": "https://github.com/Icathian-Rain/Tenda/blob/main/AC15/7.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2018-10-29 12:29
Modified
2024-11-21 03:56
Severity ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "page" parameter of the function "fromAddressNat" for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-05/Tenda.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-05/Tenda.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44_cn | |
tenda | ac7 | - | |
tenda | ac9_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac9 | - | |
tenda | ac10_firmware | 15.03.06.23_cn | |
tenda | ac10 | - | |
tenda | ac15_firmware | 15.03.05.19_cn | |
tenda | ac15 | - | |
tenda | ac18_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac18 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44_cn:*:*:*:*:*:*:*", "matchCriteriaId": "EA048307-E3FA-4868-81E2-489CBCD6D27F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "D433B9D2-8F7E-45B7-99EF-50E96B14B324", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23_cn:*:*:*:*:*:*:*", "matchCriteriaId": "39FE2B83-C4C4-4A4B-9F40-A6E340F067A7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*", "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19_cn:*:*:*:*:*:*:*", "matchCriteriaId": "A7FDBF96-9556-4B5C-ADBD-ED5E83557159", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "9AA6A0CA-46AB-4C6F-B4F8-8F3A4D9A71F5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"page\" parameter of the function \"fromAddressNat\" for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function." }, { "lang": "es", "value": "Se ha descubierto un problema en dispositivos Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN y AC18 V15.03.05.19(6318)_CN. Es una vulnerabilidad de desbordamiento de b\u00fafer en el servidor web del router, httpd. Al procesar el par\u00e1metro page de la funci\u00f3n fromAddressNat para una petici\u00f3n POST, el valor se emplea directamente en una llamada sprintf a una variable local colocada en la pila, que sobrescribe la direcci\u00f3n de retorno de la funci\u00f3n." } ], "id": "CVE-2018-18708", "lastModified": "2024-11-21T03:56:25.030", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-10-29T12:29:05.617", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-05/Tenda.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-05/Tenda.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-07-13 19:15
Modified
2024-11-21 04:56
Severity ?
Summary
A hard-coded telnet credential in the tenda_login binary of Tenda AC15 AC1900 version 15.03.05.19 allows unauthenticated remote attackers to start a telnetd service on the device.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68 | Exploit, Third Party Advisory | |
cve@mitre.org | https://www.ise.io/research/ | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68 | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.ise.io/research/ | Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.19 | |
tenda | ac15 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*", "matchCriteriaId": "A14A19EE-FB4E-4371-AC85-1401EB78B16D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A hard-coded telnet credential in the tenda_login binary of Tenda AC15 AC1900 version 15.03.05.19 allows unauthenticated remote attackers to start a telnetd service on the device." }, { "lang": "es", "value": "Una credencial de Telnet embebida en el binario tenda_login de Tenda AC15 AC1900 versi\u00f3n 15.03.05.19, permite a atacantes remotos no autenticados iniciar un servicio telnetd en el dispositivo" } ], "id": "CVE-2020-10988", "lastModified": "2024-11-21T04:56:31.627", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-07-13T19:15:12.270", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68" }, { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://www.ise.io/research/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://www.ise.io/research/" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-798" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2022-11-21 16:15
Modified
2024-11-21 07:27
Severity ?
Summary
Tenda AC15 V15.03.05.19 is vulnerable to Buffer Overflow via function formSetIpMacBind.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://drive.google.com/file/d/1dbMwByl40uqMiSv_DOEW8pFjRhGX-j97/view?usp=sharing | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://drive.google.com/file/d/1dbMwByl40uqMiSv_DOEW8pFjRhGX-j97/view?usp=sharing | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.19 | |
tenda | ac15 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*", "matchCriteriaId": "A14A19EE-FB4E-4371-AC85-1401EB78B16D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC15 V15.03.05.19 is vulnerable to Buffer Overflow via function formSetIpMacBind." }, { "lang": "es", "value": "Tenda AC15 V15.03.05.19 es vulnerable al desbordamiento del b\u00fafer a trav\u00e9s de la funci\u00f3n formSetIpMacBind." } ], "id": "CVE-2022-44156", "lastModified": "2024-11-21T07:27:40.080", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-11-21T16:15:25.803", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://drive.google.com/file/d/1dbMwByl40uqMiSv_DOEW8pFjRhGX-j97/view?usp=sharing" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://drive.google.com/file/d/1dbMwByl40uqMiSv_DOEW8pFjRhGX-j97/view?usp=sharing" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-04-24 15:15
Modified
2025-02-04 21:15
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
In Tenda AC15 V15.03.05.19, the function "sub_ED14" contains a stack-based buffer overflow vulnerability.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/2205794866/Tenda/blob/main/AC15/4.md | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/2205794866/Tenda/blob/main/AC15/4.md | Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.19 | |
tenda | ac15 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*", "matchCriteriaId": "A14A19EE-FB4E-4371-AC85-1401EB78B16D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "In Tenda AC15 V15.03.05.19, the function \"sub_ED14\" contains a stack-based buffer overflow vulnerability." } ], "id": "CVE-2023-30371", "lastModified": "2025-02-04T21:15:25.117", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2023-04-24T15:15:09.010", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://github.com/2205794866/Tenda/blob/main/AC15/4.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://github.com/2205794866/Tenda/blob/main/AC15/4.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-22 07:15
Modified
2024-11-21 09:10
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability was found in Tenda AC15 15.03.20_multi. It has been declared as critical. This vulnerability affects the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257668. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/form_fast_setting_wifi_set.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.257668 | Permissions Required | |
cna@vuldb.com | https://vuldb.com/?id.257668 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/form_fast_setting_wifi_set.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.257668 | Permissions Required | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.257668 | Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.20_multi | |
tenda | ac15 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.20_multi:*:*:*:*:*:*:*", "matchCriteriaId": "BAF4BBA3-7C56-4383-B167-933075D5C39F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC15 15.03.20_multi. It has been declared as critical. This vulnerability affects the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257668. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Se encontr\u00f3 una vulnerabilidad en Tenda AC15 15.03.20_multi. Ha sido declarada cr\u00edtica. Esta vulnerabilidad afecta a la funci\u00f3n form_fast_setting_wifi_set del archivo /goform/fast_setting_wifi_set. La manipulaci\u00f3n del argumento ssid provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque se puede iniciar de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. El identificador de esta vulnerabilidad es VDB-257668. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-2813", "lastModified": "2024-11-21T09:10:35.157", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-22T07:15:47.110", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/form_fast_setting_wifi_set.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.257668" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.257668" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/form_fast_setting_wifi_set.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.257668" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.257668" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-11-01 16:15
Modified
2024-11-05 14:30
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability was found in Tenda AC15 15.03.05.19 and classified as critical. This issue affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
References
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/theRaz0r/iot-mycve/blob/main/tenda_ac15_stackflow_formSetDeviceName/tenda_ac15_stackflow_formSetDeviceName.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.282677 | Permissions Required, Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.282677 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.434933 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://www.tenda.com.cn/ | Product |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.19 | |
tenda | ac15 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*", "matchCriteriaId": "A14A19EE-FB4E-4371-AC85-1401EB78B16D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC15 15.03.05.19 and classified as critical. This issue affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "es", "value": "Se encontr\u00f3 una vulnerabilidad en Tenda AC15 15.03.05.19 y se clasific\u00f3 como cr\u00edtica. Este problema afecta a la funci\u00f3n formSetDeviceName del archivo /goform/SetOnlineDevName. La manipulaci\u00f3n del argumento devName provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque puede iniciarse de forma remota. El exploit se ha hecho p\u00fablico y puede utilizarse." } ], "id": "CVE-2024-10662", "lastModified": "2024-11-05T14:30:16.847", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "automatable": "NOT_DEFINED", "availabilityRequirements": "NOT_DEFINED", "baseScore": 8.7, "baseSeverity": "HIGH", "confidentialityRequirements": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirements": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubsequentSystemAvailability": "NOT_DEFINED", "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED", "modifiedSubsequentSystemIntegrity": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnerableSystemAvailability": "NOT_DEFINED", "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED", "modifiedVulnerableSystemIntegrity": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "recovery": "NOT_DEFINED", "safety": "NOT_DEFINED", "subsequentSystemAvailability": "NONE", "subsequentSystemConfidentiality": "NONE", "subsequentSystemIntegrity": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnerabilityResponseEffort": "NOT_DEFINED", "vulnerableSystemAvailability": "HIGH", "vulnerableSystemConfidentiality": "HIGH", "vulnerableSystemIntegrity": "HIGH" }, "source": "cna@vuldb.com", "type": "Secondary" } ] }, "published": "2024-11-01T16:15:07.723", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/theRaz0r/iot-mycve/blob/main/tenda_ac15_stackflow_formSetDeviceName/tenda_ac15_stackflow_formSetDeviceName.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.282677" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.282677" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.434933" }, { "source": "cna@vuldb.com", "tags": [ "Product" ], "url": "https://www.tenda.com.cn/" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-22 05:15
Modified
2024-11-21 09:10
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability classified as critical has been found in Tenda AC15 15.03.05.18/15.03.20_multi. This affects the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceId/deviceMac leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257661 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/addWifiMacFilter_deviceId.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.257661 | Permissions Required | |
cna@vuldb.com | https://vuldb.com/?id.257661 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/addWifiMacFilter_deviceId.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.257661 | Permissions Required | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.257661 | Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.18 | |
tenda | ac15_firmware | 15.03.05.20_multi | |
tenda | ac15 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*", "matchCriteriaId": "56881C41-A993-45CC-BAE6-E9DE17FA56E2", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.20_multi:*:*:*:*:*:*:*", "matchCriteriaId": "BAF4BBA3-7C56-4383-B167-933075D5C39F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D5059CAD-BD1A-4808-BCED-006444E60701", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability classified as critical has been found in Tenda AC15 15.03.05.18/15.03.20_multi. This affects the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceId/deviceMac leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257661 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Una vulnerabilidad ha sido encontrada en Tenda AC15 15.03.05.18/15.03.20_multi y clasificada como cr\u00edtica. Esto afecta a la funci\u00f3n addWifiMacFilter del fichero /goform/addWifiMacFilter. La manipulaci\u00f3n del argumento deviceId/deviceMac conduce a un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. Es posible iniciar el ataque de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. A esta vulnerabilidad se le asign\u00f3 el identificador VDB-257661. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-2806", "lastModified": "2024-11-21T09:10:33.937", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-22T05:15:48.480", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/addWifiMacFilter_deviceId.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.257661" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.257661" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/addWifiMacFilter_deviceId.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.257661" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.257661" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-04-24 15:15
Modified
2025-02-05 16:15
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
In Tenda AC15 V15.03.05.19, the function "getIfIp" contains a stack-based buffer overflow vulnerability.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/2205794866/Tenda/blob/main/AC15/1.md | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/2205794866/Tenda/blob/main/AC15/1.md | Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.19 | |
tenda | ac15 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*", "matchCriteriaId": "A14A19EE-FB4E-4371-AC85-1401EB78B16D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "In Tenda AC15 V15.03.05.19, the function \"getIfIp\" contains a stack-based buffer overflow vulnerability." } ], "id": "CVE-2023-30375", "lastModified": "2025-02-05T16:15:38.913", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2023-04-24T15:15:09.137", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://github.com/2205794866/Tenda/blob/main/AC15/1.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://github.com/2205794866/Tenda/blob/main/AC15/1.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2023-04-24 15:15
Modified
2025-02-04 20:15
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
In Tenda AC15 V15.03.05.19, the function "xian_pppoe_user" contains a stack-based buffer overflow vulnerability.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.19 | |
tenda | ac15 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*", "matchCriteriaId": "A14A19EE-FB4E-4371-AC85-1401EB78B16D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "In Tenda AC15 V15.03.05.19, the function \"xian_pppoe_user\" contains a stack-based buffer overflow vulnerability." } ], "id": "CVE-2023-30373", "lastModified": "2025-02-04T20:15:47.290", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2023-04-24T15:15:09.097", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://github.com/2205794866/Tenda/blob/main/AC15/8.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://github.com/2205794866/Tenda/blob/main/AC15/8.md" }, { "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "url": "https://github.com/Icathian-Rain/Tenda/blob/main/AC15/8.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-22 08:15
Modified
2024-11-21 09:10
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability classified as critical has been found in Tenda AC15 15.03.20_multi. Affected is the function R7WebsSecurityHandler of the file /goform/execCommand of the component Cookie Handler. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257670 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/R7WebsSecurityHandler.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.257670 | Permissions Required | |
cna@vuldb.com | https://vuldb.com/?id.257670 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/R7WebsSecurityHandler.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.257670 | Permissions Required | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.257670 | Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.20_multi | |
tenda | ac15 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.20_multi:*:*:*:*:*:*:*", "matchCriteriaId": "BAF4BBA3-7C56-4383-B167-933075D5C39F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability classified as critical has been found in Tenda AC15 15.03.20_multi. Affected is the function R7WebsSecurityHandler of the file /goform/execCommand of the component Cookie Handler. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257670 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Una vulnerabilidad ha sido encontrada en Tenda AC15 15.03.20_multi y clasificada como cr\u00edtica. La funci\u00f3n R7WebsSecurityHandler del archivo /goform/execCommand del componente Cookie Handler es afectada por la vulnerabilidad. La manipulaci\u00f3n del argumento contrase\u00f1a provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. Es posible lanzar el ataque de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. VDB-257670 es el identificador asignado a esta vulnerabilidad. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-2815", "lastModified": "2024-11-21T09:10:35.470", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-22T08:15:09.750", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/R7WebsSecurityHandler.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.257670" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.257670" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/R7WebsSecurityHandler.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.257670" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.257670" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2017-11-21 14:29
Modified
2024-11-21 03:17
Severity ?
Summary
Command Injection vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to execute arbitrary OS commands via a crafted cgi-bin/luci/usbeject?dev_name= GET request from the LAN. This occurs because the "sub_A6E8 usbeject_process_entry" function executes a system function with untrusted input.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/Iolop/Poc/tree/master/Router/Tenda | Issue Tracking, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/Iolop/Poc/tree/master/Router/Tenda | Issue Tracking, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac9_firmware | us_ac9v1.0br_v15.03.05.14_multi_td01 | |
tenda | ac9 | - | |
tenda | ac9_firmware | ac9_kf_v15.03.05.19\(6318_\)_cn | |
tenda | ac9 | - | |
tenda | ac15_firmware | us_ac15v1.0br_v15.03.05.18_multi_td01 | |
tenda | ac15 | - | |
tenda | ac15_firmware | us_ac15v1.0br_v15.03.05.19_multi_td01 | |
tenda | ac15 | - | |
tenda | ac18_firmware | us_ac18v1.0br_v15.03.05.05_multi_td01 | |
tenda | ac18 | - | |
tenda | ac18_firmware | ac18_kf_v15.03.05.19\(6318_\)_cn | |
tenda | ac18 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:us_ac9v1.0br_v15.03.05.14_multi_td01:*:*:*:*:*:*:*", "matchCriteriaId": "A892AC99-F24B-4E0F-B3F0-CDBE1F4AD446", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:ac9_kf_v15.03.05.19\\(6318_\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "512EB7D7-B12E-4219-8270-9EFCC8F6F366", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:us_ac15v1.0br_v15.03.05.18_multi_td01:*:*:*:*:*:*:*", "matchCriteriaId": "6A51B455-6ABD-4827-B948-7341D353C05E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:us_ac15v1.0br_v15.03.05.19_multi_td01:*:*:*:*:*:*:*", "matchCriteriaId": "9535D5AC-FCE6-40A9-BA55-10DFE110BBBC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac18_firmware:us_ac18v1.0br_v15.03.05.05_multi_td01:*:*:*:*:*:*:*", "matchCriteriaId": "35D8463B-CC09-4C38-9881-4D7E3EC2B635", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac18_firmware:ac18_kf_v15.03.05.19\\(6318_\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "72C6CF57-11B7-4A11-AA61-248ACAFE624C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Command Injection vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to execute arbitrary OS commands via a crafted cgi-bin/luci/usbeject?dev_name= GET request from the LAN. This occurs because the \"sub_A6E8 usbeject_process_entry\" function executes a system function with untrusted input." }, { "lang": "es", "value": "Vulnerabilidad de inyecci\u00f3n de comandos en app_data_center en dispositivos Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01 y Ac18 ac18_kf_V15.03.05.19(6318_)_cn permite que los atacantes remotos no autenticados ejecuten comandos de sistema operativo arbitrarios mediante una petici\u00f3n GET cgi-bin/luci/usbeject?dev_name= manipulada desde la red LAN. Esto ocurre porque la funci\u00f3n \"sub_A6E8 usbeject_process_entry\" ejecuta una funci\u00f3n del sistema con valores de entrada no fiables." } ], "id": "CVE-2017-16923", "lastModified": "2024-11-21T03:17:14.913", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2017-11-21T14:29:00.260", "references": [ { "source": "cve@mitre.org", "tags": [ "Issue Tracking", "Third Party Advisory" ], "url": "https://github.com/Iolop/Poc/tree/master/Router/Tenda" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Issue Tracking", "Third Party Advisory" ], "url": "https://github.com/Iolop/Poc/tree/master/Router/Tenda" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2018-10-29 12:29
Modified
2024-11-21 03:56
Severity ?
Summary
An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. They allow remote code execution via shell metacharacters in the usbName field to the __fastcall function with a POST request.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/ZIllR0/Routers/blob/master/Tenda/rce1.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/ZIllR0/Routers/blob/master/Tenda/rce1.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac9_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac9 | - | |
tenda | ac15_firmware | 15.03.05.19_cn | |
tenda | ac15 | - | |
tenda | ac18_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac18 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "D433B9D2-8F7E-45B7-99EF-50E96B14B324", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19_cn:*:*:*:*:*:*:*", "matchCriteriaId": "A7FDBF96-9556-4B5C-ADBD-ED5E83557159", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "9AA6A0CA-46AB-4C6F-B4F8-8F3A4D9A71F5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. They allow remote code execution via shell metacharacters in the usbName field to the __fastcall function with a POST request." }, { "lang": "es", "value": "Se ha descubierto un problema en dispositivos Tenda AC9 V15.03.05.19(6318)_CN, AC15 V15.03.05.19_CN y AC18 V15.03.05.19(6318)_CN. Permiten la ejecuci\u00f3n remota de c\u00f3digo mediante metacaracteres shell en el campo usbName en la funci\u00f3n __fastcall con una petici\u00f3n POST." } ], "id": "CVE-2018-18728", "lastModified": "2024-11-21T03:56:28.030", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-10-29T12:29:07.507", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/rce1.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/rce1.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-22 06:15
Modified
2024-11-21 09:10
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability has been found in Tenda AC15 15.03.05.18/15.03.20_multi and classified as critical. Affected by this vulnerability is the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257665 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formWifiWpsOOB.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.257665 | Permissions Required | |
cna@vuldb.com | https://vuldb.com/?id.257665 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formWifiWpsOOB.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.257665 | Permissions Required | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.257665 | Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.18 | |
tenda | ac15_firmware | 15.03.05.20_multi | |
tenda | ac15 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*", "matchCriteriaId": "56881C41-A993-45CC-BAE6-E9DE17FA56E2", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.20_multi:*:*:*:*:*:*:*", "matchCriteriaId": "BAF4BBA3-7C56-4383-B167-933075D5C39F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D5059CAD-BD1A-4808-BCED-006444E60701", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been found in Tenda AC15 15.03.05.18/15.03.20_multi and classified as critical. Affected by this vulnerability is the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257665 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Una vulnerabilidad ha sido encontrada en Tenda AC15 15.03.05.18/15.03.20_multi y clasificada como cr\u00edtica. La funci\u00f3n formWifiWpsOOB del archivo /goform/WifiWpsOOB es afectada por esta vulnerabilidad. La manipulaci\u00f3n del \u00edndice de argumentos conduce a un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque se puede lanzar de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. A esta vulnerabilidad se le asign\u00f3 el identificador VDB-257665. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-2810", "lastModified": "2024-11-21T09:10:34.653", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-22T06:15:10.800", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formWifiWpsOOB.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.257665" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.257665" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formWifiWpsOOB.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.257665" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.257665" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-24 06:15
Modified
2024-11-21 09:10
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.05.19/15.03.20. Affected by this vulnerability is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257779. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/fromSetSysTime.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.257779 | Permissions Required | |
cna@vuldb.com | https://vuldb.com/?id.257779 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/fromSetSysTime.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.257779 | Permissions Required | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.257779 | Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.18 | |
tenda | ac15_firmware | 15.03.05.19 | |
tenda | ac15_firmware | 15.03.20_multi | |
tenda | ac15 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*", "matchCriteriaId": "56881C41-A993-45CC-BAE6-E9DE17FA56E2", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*", "matchCriteriaId": "A14A19EE-FB4E-4371-AC85-1401EB78B16D", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.20_multi:*:*:*:*:*:*:*", "matchCriteriaId": "F22EDEAA-555B-4627-A25B-F6D5649A8275", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D5059CAD-BD1A-4808-BCED-006444E60701", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.05.19/15.03.20. Affected by this vulnerability is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257779. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Una vulnerabilidad fue encontrada en Tenda AC15 15.03.05.18/15.03.05.19/15.03.20 y clasificada como cr\u00edtica. La funci\u00f3n fromSetSysTime del archivo /goform/SetSysTimeCfg es afectada por esta vulnerabilidad. La manipulaci\u00f3n del tiempo del argumento conduce a un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque se puede lanzar de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. El identificador asociado de esta vulnerabilidad es VDB-257779. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-2855", "lastModified": "2024-11-21T09:10:41.300", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-24T06:15:11.860", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/fromSetSysTime.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.257779" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.257779" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/fromSetSysTime.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.257779" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.257779" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2018-10-29 12:29
Modified
2024-11-21 03:56
Severity ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a heap-based buffer overflow vulnerability in the router's web server -- httpd. While processing the 'mac' parameter for a post request, the value is directly used in a strcpy to a variable placed on the heap, which can leak sensitive information or even hijack program control flow.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/ZIllR0/Routers/blob/master/Tenda/heapoverflow1.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/ZIllR0/Routers/blob/master/Tenda/heapoverflow1.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44_cn | |
tenda | ac7 | - | |
tenda | ac9_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac9 | - | |
tenda | ac10_firmware | 15.03.06.23_cn | |
tenda | ac10 | - | |
tenda | ac15_firmware | 15.03.05.19_cn | |
tenda | ac15 | - | |
tenda | ac18_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac18 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44_cn:*:*:*:*:*:*:*", "matchCriteriaId": "EA048307-E3FA-4868-81E2-489CBCD6D27F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "D433B9D2-8F7E-45B7-99EF-50E96B14B324", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23_cn:*:*:*:*:*:*:*", "matchCriteriaId": "39FE2B83-C4C4-4A4B-9F40-A6E340F067A7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*", "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19_cn:*:*:*:*:*:*:*", "matchCriteriaId": "A7FDBF96-9556-4B5C-ADBD-ED5E83557159", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "9AA6A0CA-46AB-4C6F-B4F8-8F3A4D9A71F5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a heap-based buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027mac\u0027 parameter for a post request, the value is directly used in a strcpy to a variable placed on the heap, which can leak sensitive information or even hijack program control flow." }, { "lang": "es", "value": "Se ha descubierto un problema en dispositivos Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN y AC18 V15.03.05.19(6318)_CN. Es una vulnerabilidad de desbordamiento de b\u00fafer basado en memoria din\u00e1mica (heap) en el servidor web del router, httpd. Al procesar el par\u00e1metro mac para una petici\u00f3n POST, el valor se emplea directamente en una llamada strcpy a una variable en el heap, que puede filtrar informaci\u00f3n sensible o secuestrar el flujo de control del programa." } ], "id": "CVE-2018-18729", "lastModified": "2024-11-21T03:56:28.197", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 8.5, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-10-29T12:29:07.617", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/heapoverflow1.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/heapoverflow1.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-22 06:15
Modified
2024-11-21 09:10
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability was found in Tenda AC15 15.03.20_multi and classified as critical. Affected by this issue is the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257666 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formWifiWpsStart.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.257666 | Permissions Required | |
cna@vuldb.com | https://vuldb.com/?id.257666 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formWifiWpsStart.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.257666 | Permissions Required | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.257666 | Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.20_multi | |
tenda | ac15 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.20_multi:*:*:*:*:*:*:*", "matchCriteriaId": "BAF4BBA3-7C56-4383-B167-933075D5C39F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC15 15.03.20_multi and classified as critical. Affected by this issue is the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257666 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Una vulnerabilidad fue encontrada en Tenda AC15 15.03.20_multi y clasificada como cr\u00edtica. La funci\u00f3n formWifiWpsStart del archivo /goform/WifiWpsStart es afectada por esta vulnerabilidad. La manipulaci\u00f3n del \u00edndice de argumentos conduce a un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque puede lanzarse de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. VDB-257666 es el identificador asignado a esta vulnerabilidad. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-2811", "lastModified": "2024-11-21T09:10:34.833", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-22T06:15:11.803", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formWifiWpsStart.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.257666" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.257666" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formWifiWpsStart.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.257666" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.257666" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-04-24 14:15
Modified
2025-02-04 21:15
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Tenda AC15 V15.03.05.19 is vulnerable to Buffer Overflow.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/2205794866/Tenda/blob/main/AC15/3.md | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/2205794866/Tenda/blob/main/AC15/3.md | Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.19 | |
tenda | ac15 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*", "matchCriteriaId": "A14A19EE-FB4E-4371-AC85-1401EB78B16D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC15 V15.03.05.19 is vulnerable to Buffer Overflow." } ], "id": "CVE-2023-30369", "lastModified": "2025-02-04T21:15:24.710", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2023-04-24T14:15:07.903", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://github.com/2205794866/Tenda/blob/main/AC15/3.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://github.com/2205794866/Tenda/blob/main/AC15/3.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2018-10-29 12:29
Modified
2024-11-21 03:56
Severity ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'deviceMac' parameter for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/ZIllR0/Routers/blob/master/Tenda/stack4.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/ZIllR0/Routers/blob/master/Tenda/stack4.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44_cn | |
tenda | ac7 | - | |
tenda | ac9_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac9 | - | |
tenda | ac10_firmware | 15.03.06.23_cn | |
tenda | ac10 | - | |
tenda | ac15_firmware | 15.03.05.19_cn | |
tenda | ac15 | - | |
tenda | ac18_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac18 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44_cn:*:*:*:*:*:*:*", "matchCriteriaId": "EA048307-E3FA-4868-81E2-489CBCD6D27F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "D433B9D2-8F7E-45B7-99EF-50E96B14B324", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23_cn:*:*:*:*:*:*:*", "matchCriteriaId": "39FE2B83-C4C4-4A4B-9F40-A6E340F067A7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*", "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19_cn:*:*:*:*:*:*:*", "matchCriteriaId": "A7FDBF96-9556-4B5C-ADBD-ED5E83557159", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "9AA6A0CA-46AB-4C6F-B4F8-8F3A4D9A71F5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027deviceMac\u0027 parameter for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function." }, { "lang": "es", "value": "Se ha descubierto un problema en dispositivos Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN y AC18 V15.03.05.19(6318)_CN. Es una vulnerabilidad de desbordamiento de b\u00fafer en el servidor web del router, httpd. Al procesar el par\u00e1metro deviceMac para una petici\u00f3n POST, el valor se emplea directamente en una llamada sprintf a una variable local colocada en la pila, que sobrescribe la direcci\u00f3n de retorno de la funci\u00f3n." } ], "id": "CVE-2018-18731", "lastModified": "2024-11-21T03:56:28.527", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-10-29T12:29:07.837", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack4.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack4.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-24 05:15
Modified
2024-11-21 09:10
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability was found in Tenda AC15 15.03.20_multi. It has been declared as critical. This vulnerability affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257776. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/saveParentControlInfo_urls.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.257776 | Permissions Required | |
cna@vuldb.com | https://vuldb.com/?id.257776 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/saveParentControlInfo_urls.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.257776 | Permissions Required | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.257776 | Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.20_multi | |
tenda | ac15 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.20_multi:*:*:*:*:*:*:*", "matchCriteriaId": "F22EDEAA-555B-4627-A25B-F6D5649A8275", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D5059CAD-BD1A-4808-BCED-006444E60701", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC15 15.03.20_multi. It has been declared as critical. This vulnerability affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257776. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Se encontr\u00f3 una vulnerabilidad en Tenda AC15 15.03.20_multi. Ha sido declarada cr\u00edtica. Esta vulnerabilidad afecta a la funci\u00f3n saveParentControlInfo del archivo /goform/saveParentControlInfo. La manipulaci\u00f3n de las URL de argumentos conduce a un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque se puede iniciar de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. El identificador de esta vulnerabilidad es VDB-257776. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-2852", "lastModified": "2024-11-21T09:10:40.773", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-24T05:15:09.160", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/saveParentControlInfo_urls.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.257776" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.257776" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/saveParentControlInfo_urls.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.257776" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.257776" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-22 08:15
Modified
2024-11-21 09:10
Severity ?
4.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H
Summary
A vulnerability classified as problematic was found in Tenda AC15 15.03.05.18. Affected by this vulnerability is the function fromSysToolReboot of the file /goform/SysToolReboot. The manipulation leads to cross-site request forgery. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257671. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/fromSysToolReboot.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.257671 | Permissions Required | |
cna@vuldb.com | https://vuldb.com/?id.257671 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/fromSysToolReboot.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.257671 | Permissions Required | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.257671 | Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.18 | |
tenda | ac15 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*", "matchCriteriaId": "56881C41-A993-45CC-BAE6-E9DE17FA56E2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability classified as problematic was found in Tenda AC15 15.03.05.18. Affected by this vulnerability is the function fromSysToolReboot of the file /goform/SysToolReboot. The manipulation leads to cross-site request forgery. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257671. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Una vulnerabilidad fue encontrada en Tenda AC15 15.03.05.18 y clasificada como problem\u00e1tica. La funci\u00f3n fromSysToolReboot del archivo /goform/SysToolReboot es afectada por esta vulnerabilidad. La manipulaci\u00f3n conduce a cross-site request forgery. El ataque se puede lanzar de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. El identificador asociado de esta vulnerabilidad es VDB-257671. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-2816", "lastModified": "2024-11-21T09:10:35.613", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 1.4, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-22T08:15:10.010", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/fromSysToolReboot.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.257671" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.257671" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/fromSysToolReboot.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.257671" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.257671" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-352" } ], "source": "cna@vuldb.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2018-10-29 12:29
Modified
2024-11-21 03:56
Severity ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'deviceList' parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/ZIllR0/Routers/blob/master/Tenda/stack1.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/ZIllR0/Routers/blob/master/Tenda/stack1.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44_cn | |
tenda | ac7 | - | |
tenda | ac9_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac9 | - | |
tenda | ac10_firmware | 15.03.06.23_cn | |
tenda | ac10 | - | |
tenda | ac15_firmware | 15.03.05.19_cn | |
tenda | ac15 | - | |
tenda | ac18_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac18 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44_cn:*:*:*:*:*:*:*", "matchCriteriaId": "EA048307-E3FA-4868-81E2-489CBCD6D27F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "D433B9D2-8F7E-45B7-99EF-50E96B14B324", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23_cn:*:*:*:*:*:*:*", "matchCriteriaId": "39FE2B83-C4C4-4A4B-9F40-A6E340F067A7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*", "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19_cn:*:*:*:*:*:*:*", "matchCriteriaId": "A7FDBF96-9556-4B5C-ADBD-ED5E83557159", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "9AA6A0CA-46AB-4C6F-B4F8-8F3A4D9A71F5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027deviceList\u0027 parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function." }, { "lang": "es", "value": "Se ha descubierto un problema en dispositivos Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN y AC18 V15.03.05.19(6318)_CN. Es una vulnerabilidad de desbordamiento de b\u00fafer en el servidor web del router, httpd. Al procesar el par\u00e1metro deviceList para una petici\u00f3n POST, el valor se emplea directamente en una llamada strcpy a una variable local colocada en la pila, que sobrescribe la direcci\u00f3n de retorno de la funci\u00f3n." } ], "id": "CVE-2018-18727", "lastModified": "2024-11-21T03:56:27.863", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-10-29T12:29:07.400", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack1.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack1.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2018-10-29 12:29
Modified
2024-11-21 03:56
Severity ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'ntpServer' parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/ZIllR0/Routers/blob/master/Tenda/stack2.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/ZIllR0/Routers/blob/master/Tenda/stack2.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44_cn | |
tenda | ac7 | - | |
tenda | ac9_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac9 | - | |
tenda | ac10_firmware | 15.03.06.23_cn | |
tenda | ac10 | - | |
tenda | ac15_firmware | 15.03.05.19_cn | |
tenda | ac15 | - | |
tenda | ac18_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac18 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44_cn:*:*:*:*:*:*:*", "matchCriteriaId": "EA048307-E3FA-4868-81E2-489CBCD6D27F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "D433B9D2-8F7E-45B7-99EF-50E96B14B324", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23_cn:*:*:*:*:*:*:*", "matchCriteriaId": "39FE2B83-C4C4-4A4B-9F40-A6E340F067A7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*", "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19_cn:*:*:*:*:*:*:*", "matchCriteriaId": "A7FDBF96-9556-4B5C-ADBD-ED5E83557159", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "9AA6A0CA-46AB-4C6F-B4F8-8F3A4D9A71F5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027ntpServer\u0027 parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function." }, { "lang": "es", "value": "Se ha descubierto un problema en dispositivos Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN y AC18 V15.03.05.19(6318)_CN. Es una vulnerabilidad de desbordamiento de b\u00fafer en el servidor web del router, httpd. Al procesar el par\u00e1metro ntpServer para una petici\u00f3n POST, el valor se emplea directamente en una llamada strcpy a una variable local colocada en la pila, que sobrescribe la direcci\u00f3n de retorno de la funci\u00f3n." } ], "id": "CVE-2018-18732", "lastModified": "2024-11-21T03:56:28.703", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-10-29T12:29:07.960", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack2.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack2.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-22 06:15
Modified
2024-11-21 09:10
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability, which was classified as critical, was found in Tenda AC15 15.03.05.18/15.03.20_multi. Affected is the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257664. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formSetFirewallCfg.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.257664 | Permissions Required | |
cna@vuldb.com | https://vuldb.com/?id.257664 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formSetFirewallCfg.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.257664 | Permissions Required | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.257664 | Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.18 | |
tenda | ac15_firmware | 15.03.05.20_multi | |
tenda | ac15 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*", "matchCriteriaId": "56881C41-A993-45CC-BAE6-E9DE17FA56E2", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.20_multi:*:*:*:*:*:*:*", "matchCriteriaId": "BAF4BBA3-7C56-4383-B167-933075D5C39F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D5059CAD-BD1A-4808-BCED-006444E60701", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, was found in Tenda AC15 15.03.05.18/15.03.20_multi. Affected is the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257664. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Una vulnerabilidad fue encontrada en Tenda AC15 15.03.05.18/15.03.20_multi y clasificada como cr\u00edtica. La funci\u00f3n formSetFirewallCfg del fichero /goform/SetFirewallCfg es afectada por la vulnerabilidad. La manipulaci\u00f3n del argumento firewallEn conduce a un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. Es posible lanzar el ataque de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. El identificador de esta vulnerabilidad es VDB-257664. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-2809", "lastModified": "2024-11-21T09:10:34.453", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-22T06:15:08.747", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formSetFirewallCfg.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.257664" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.257664" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formSetFirewallCfg.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.257664" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.257664" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-22 05:15
Modified
2024-11-21 09:10
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability, which was classified as critical, has been found in Tenda AC15 15.03.05.18/15.03.20_multi. This issue affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257663. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formQuickIndex.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.257663 | Permissions Required | |
cna@vuldb.com | https://vuldb.com/?id.257663 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formQuickIndex.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.257663 | Permissions Required | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.257663 | Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.18 | |
tenda | ac15_firmware | 15.03.05.20_multi | |
tenda | ac15 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*", "matchCriteriaId": "56881C41-A993-45CC-BAE6-E9DE17FA56E2", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.20_multi:*:*:*:*:*:*:*", "matchCriteriaId": "BAF4BBA3-7C56-4383-B167-933075D5C39F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D5059CAD-BD1A-4808-BCED-006444E60701", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, has been found in Tenda AC15 15.03.05.18/15.03.20_multi. This issue affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257663. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Una vulnerabilidad fue encontrada en Tenda AC15 15.03.05.18/15.03.20_multi y clasificada como cr\u00edtica. Este problema afecta la funci\u00f3n formQuickIndex del archivo /goform/QuickIndex. La manipulaci\u00f3n del argumento PPPOEPassword provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque puede iniciarse de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. El identificador asociado de esta vulnerabilidad es VDB-257663. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-2808", "lastModified": "2024-11-21T09:10:34.280", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-22T05:15:49.017", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formQuickIndex.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.257663" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.257663" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formQuickIndex.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.257663" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.257663" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-22 07:15
Modified
2024-11-21 09:10
Severity ?
6.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been classified as critical. This affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257667. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formWriteFacMac.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.257667 | Permissions Required | |
cna@vuldb.com | https://vuldb.com/?id.257667 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formWriteFacMac.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.257667 | Permissions Required | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.257667 | Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.18 | |
tenda | ac15_firmware | 15.03.05.20_multi | |
tenda | ac15 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*", "matchCriteriaId": "56881C41-A993-45CC-BAE6-E9DE17FA56E2", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.20_multi:*:*:*:*:*:*:*", "matchCriteriaId": "BAF4BBA3-7C56-4383-B167-933075D5C39F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D5059CAD-BD1A-4808-BCED-006444E60701", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been classified as critical. This affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257667. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Se encontr\u00f3 una vulnerabilidad en Tenda AC15 15.03.05.18/15.03.20_multi. Ha sido clasificada como cr\u00edtica. Esto afecta a la funci\u00f3n formWriteFacMac del archivo /goform/WriteFacMac. La manipulaci\u00f3n del argumento mac conduce a la inyecci\u00f3n de comandos del sistema operativo. Es posible iniciar el ataque de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. El identificador asociado de esta vulnerabilidad es VDB-257667. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-2812", "lastModified": "2024-11-21T09:10:34.993", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 6.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.4, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-22T07:15:46.283", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formWriteFacMac.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.257667" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.257667" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formWriteFacMac.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.257667" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.257667" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "cna@vuldb.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-24 03:15
Modified
2024-11-21 09:10
Severity ?
6.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been classified as critical. This affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257775. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/formSetSambaConf.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.257775 | Permissions Required | |
cna@vuldb.com | https://vuldb.com/?id.257775 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/formSetSambaConf.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.257775 | Permissions Required | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.257775 | Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.18 | |
tenda | ac15_firmware | 15.03.20_multi | |
tenda | ac15 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*", "matchCriteriaId": "56881C41-A993-45CC-BAE6-E9DE17FA56E2", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.20_multi:*:*:*:*:*:*:*", "matchCriteriaId": "F22EDEAA-555B-4627-A25B-F6D5649A8275", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been classified as critical. This affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257775. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Se encontr\u00f3 una vulnerabilidad en Tenda AC15 15.03.05.18/15.03.20_multi. Ha sido clasificada como cr\u00edtica. Esto afecta a la funci\u00f3n formSetSambaConf del archivo /goform/setsambacfg. La manipulaci\u00f3n del argumento usbName conduce a la inyecci\u00f3n de comandos del sistema operativo. Es posible iniciar el ataque de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. El identificador asociado de esta vulnerabilidad es VDB-257775. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-2851", "lastModified": "2024-11-21T09:10:40.600", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 6.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.4, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-24T03:15:09.177", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/formSetSambaConf.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.257775" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.257775" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/formSetSambaConf.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.257775" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.257775" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "cna@vuldb.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2022-01-28 19:15
Modified
2024-11-21 06:31
Severity ?
Summary
Multiple Tenda devices are affected by authentication bypass, such as AC15V1.0 Firmware V15.03.05.20_multi?AC5V1.0 Firmware V15.03.06.48_multi and so on. an attacker can obtain sensitive information, and even combine it with authenticated command injection to implement RCE.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | http://ac15v10.com | Broken Link, URL Repurposed | |
cve@mitre.org | http://tenda.com | Vendor Advisory | |
cve@mitre.org | https://github.com/21Gun5/my_cve/blob/main/tenda/bypass_auth.md | Broken Link | |
af854a3a-2127-422b-91ae-364da2661108 | http://ac15v10.com | Broken Link, URL Repurposed | |
af854a3a-2127-422b-91ae-364da2661108 | http://tenda.com | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/21Gun5/my_cve/blob/main/tenda/bypass_auth.md | Broken Link |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.20_multi | |
tenda | ac15 | 1.0 | |
tenda | ac5_firmware | 15.03.06.48_multi | |
tenda | ac5 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.20_multi:*:*:*:*:*:*:*", "matchCriteriaId": "BAF4BBA3-7C56-4383-B167-933075D5C39F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D5059CAD-BD1A-4808-BCED-006444E60701", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.48_multi:*:*:*:*:*:*:*", "matchCriteriaId": "E540AF96-2B4E-4223-B15A-8DA89D2D12F1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Multiple Tenda devices are affected by authentication bypass, such as AC15V1.0 Firmware V15.03.05.20_multi?AC5V1.0 Firmware V15.03.06.48_multi and so on. an attacker can obtain sensitive information, and even combine it with authenticated command injection to implement RCE." }, { "lang": "es", "value": "M\u00faltiples dispositivos Tenda est\u00e1n afectados por una omisi\u00f3n de autenticaci\u00f3n, como AC15V1.0 Firmware versi\u00f3n V15.03.05.20_multi... AC5V1.0 Firmware versi\u00f3n V15.03.06.48_multi, etc. un atacante puede obtener informaci\u00f3n confidencial, e incluso combinarla con una inyecci\u00f3n de comandos autenticados para implementar RCE" } ], "id": "CVE-2021-44971", "lastModified": "2024-11-21T06:31:45.903", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-01-28T19:15:07.963", "references": [ { "source": "cve@mitre.org", "tags": [ "Broken Link", "URL Repurposed" ], "url": "http://ac15v10.com" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "http://tenda.com" }, { "source": "cve@mitre.org", "tags": [ "Broken Link" ], "url": "https://github.com/21Gun5/my_cve/blob/main/tenda/bypass_auth.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link", "URL Repurposed" ], "url": "http://ac15v10.com" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "http://tenda.com" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link" ], "url": "https://github.com/21Gun5/my_cve/blob/main/tenda/bypass_auth.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-697" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2022-08-19 21:15
Modified
2024-11-21 07:14
Severity ?
Summary
Tenda ac15 firmware V15.03.05.18 httpd server has stack buffer overflow in /goform/formWifiBasicSet.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://drive.google.com/file/d/16hshiCHS8j3YaFPkQD3xajVuwu_QVBe3/view | Third Party Advisory | |
cve@mitre.org | https://www.cnblogs.com/Amalll/p/16527552.html | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://drive.google.com/file/d/16hshiCHS8j3YaFPkQD3xajVuwu_QVBe3/view | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.cnblogs.com/Amalll/p/16527552.html | Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.18 | |
tenda | ac15 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*", "matchCriteriaId": "56881C41-A993-45CC-BAE6-E9DE17FA56E2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda ac15 firmware V15.03.05.18 httpd server has stack buffer overflow in /goform/formWifiBasicSet." }, { "lang": "es", "value": "Tenda ac15 firmware V15.03.05.18, el servidor httpd presenta desbordamiento de b\u00fafer de pila en /goform/formWifiBasicSet." } ], "id": "CVE-2022-37175", "lastModified": "2024-11-21T07:14:33.800", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-08-19T21:15:09.000", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://drive.google.com/file/d/16hshiCHS8j3YaFPkQD3xajVuwu_QVBe3/view" }, { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://www.cnblogs.com/Amalll/p/16527552.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://drive.google.com/file/d/16hshiCHS8j3YaFPkQD3xajVuwu_QVBe3/view" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://www.cnblogs.com/Amalll/p/16527552.html" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-04-24 15:15
Modified
2025-02-04 20:15
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
In Tenda AC15 V15.03.05.19, The function "xkjs_ver32" contains a stack-based buffer overflow vulnerability.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.19 | |
tenda | ac15 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*", "matchCriteriaId": "A14A19EE-FB4E-4371-AC85-1401EB78B16D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "In Tenda AC15 V15.03.05.19, The function \"xkjs_ver32\" contains a stack-based buffer overflow vulnerability." } ], "id": "CVE-2023-30372", "lastModified": "2025-02-04T20:15:47.100", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2023-04-24T15:15:09.053", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://github.com/2205794866/Tenda/blob/main/AC15/10.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://github.com/2205794866/Tenda/blob/main/AC15/10.md" }, { "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "url": "https://github.com/Icathian-Rain/Tenda/blob/main/AC15/10.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-22 08:15
Modified
2024-11-21 09:10
Severity ?
4.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H
Summary
A vulnerability, which was classified as problematic, has been found in Tenda AC15 15.03.05.18. Affected by this issue is the function fromSysToolRestoreSet of the file /goform/SysToolRestoreSet. The manipulation leads to cross-site request forgery. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257672. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/fromSysToolRestoreSet.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.257672 | Permissions Required | |
cna@vuldb.com | https://vuldb.com/?id.257672 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/fromSysToolRestoreSet.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.257672 | Permissions Required | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.257672 | Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.18 | |
tenda | ac15 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*", "matchCriteriaId": "56881C41-A993-45CC-BAE6-E9DE17FA56E2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as problematic, has been found in Tenda AC15 15.03.05.18. Affected by this issue is the function fromSysToolRestoreSet of the file /goform/SysToolRestoreSet. The manipulation leads to cross-site request forgery. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257672. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Una vulnerabilidad fue encontrada en Tenda AC15 15.03.05.18 y clasificada como problem\u00e1tica. La funci\u00f3n fromSysToolRestoreSet del archivo /goform/SysToolRestoreSet es afectada por esta vulnerabilidad. La manipulaci\u00f3n conduce a cross-site request forgery. El ataque puede lanzarse de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. El identificador de esta vulnerabilidad es VDB-257672. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-2817", "lastModified": "2024-11-21T09:10:35.773", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 1.4, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-22T08:15:10.257", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/fromSysToolRestoreSet.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.257672" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.257672" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/fromSysToolRestoreSet.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.257672" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.257672" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-352" } ], "source": "cna@vuldb.com", "type": "Primary" } ] }
cve-2022-40851
Vulnerability from cvelistv5
Published
2022-09-23 14:02
Modified
2024-08-03 12:28
Severity ?
EPSS score ?
Summary
Tenda AC15 V15.03.05.19 contained a stack overflow via the function fromAddressNat.
References
▼ | URL | Tags |
---|---|---|
https://github.com/CPSeek/Router-vuls/blob/main/Tenda/AC15/addressNat.md | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T12:28:42.571Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/CPSeek/Router-vuls/blob/main/Tenda/AC15/addressNat.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC15 V15.03.05.19 contained a stack overflow via the function fromAddressNat." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-09-23T14:02:51", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/CPSeek/Router-vuls/blob/main/Tenda/AC15/addressNat.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2022-40851", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Tenda AC15 V15.03.05.19 contained a stack overflow via the function fromAddressNat." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/CPSeek/Router-vuls/blob/main/Tenda/AC15/addressNat.md", "refsource": "MISC", "url": "https://github.com/CPSeek/Router-vuls/blob/main/Tenda/AC15/addressNat.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-40851", "datePublished": "2022-09-23T14:02:51", "dateReserved": "2022-09-19T00:00:00", "dateUpdated": "2024-08-03T12:28:42.571Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-10989
Vulnerability from cvelistv5
Published
2020-07-13 18:04
Modified
2024-08-04 11:21
Severity ?
EPSS score ?
Summary
An XSS issue in the /goform/WifiBasicSet endpoint of Tenda AC15 AC1900 version 15.03.05.19 allows remote attackers to execute malicious payloads via the WifiName POST parameter.
References
▼ | URL | Tags |
---|---|---|
https://www.ise.io/research/ | x_refsource_MISC | |
https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68 | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T11:21:14.474Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.ise.io/research/" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "An XSS issue in the /goform/WifiBasicSet endpoint of Tenda AC15 AC1900 version 15.03.05.19 allows remote attackers to execute malicious payloads via the WifiName POST parameter." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-07-13T18:04:36", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.ise.io/research/" }, { "tags": [ "x_refsource_MISC" ], "url": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-10989", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An XSS issue in the /goform/WifiBasicSet endpoint of Tenda AC15 AC1900 version 15.03.05.19 allows remote attackers to execute malicious payloads via the WifiName POST parameter." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.ise.io/research/", "refsource": "MISC", "url": "https://www.ise.io/research/" }, { "name": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68", "refsource": "MISC", "url": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-10989", "datePublished": "2020-07-13T18:04:36", "dateReserved": "2020-03-26T00:00:00", "dateUpdated": "2024-08-04T11:21:14.474Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-10986
Vulnerability from cvelistv5
Published
2020-07-13 17:59
Modified
2024-08-04 11:21
Severity ?
EPSS score ?
Summary
A CSRF issue in the /goform/SysToolReboot endpoint of Tenda AC15 AC1900 version 15.03.05.19 allows remote attackers to reboot the device and cause denial of service via a payload hosted by an attacker-controlled web page.
References
▼ | URL | Tags |
---|---|---|
https://www.ise.io/research/ | x_refsource_MISC | |
https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68 | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T11:21:14.425Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.ise.io/research/" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A CSRF issue in the /goform/SysToolReboot endpoint of Tenda AC15 AC1900 version 15.03.05.19 allows remote attackers to reboot the device and cause denial of service via a payload hosted by an attacker-controlled web page." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-07-13T17:59:19", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.ise.io/research/" }, { "tags": [ "x_refsource_MISC" ], "url": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-10986", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CSRF issue in the /goform/SysToolReboot endpoint of Tenda AC15 AC1900 version 15.03.05.19 allows remote attackers to reboot the device and cause denial of service via a payload hosted by an attacker-controlled web page." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.ise.io/research/", "refsource": "MISC", "url": "https://www.ise.io/research/" }, { "name": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68", "refsource": "MISC", "url": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-10986", "datePublished": "2020-07-13T17:59:19", "dateReserved": "2020-03-26T00:00:00", "dateUpdated": "2024-08-04T11:21:14.425Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-2852
Vulnerability from cvelistv5
Published
2024-03-24 04:31
Modified
2024-08-01 19:25
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS score ?
Summary
A vulnerability was found in Tenda AC15 15.03.20_multi. It has been declared as critical. This vulnerability affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257776. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.257776 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.257776 | signature, permissions-required | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/saveParentControlInfo_urls.md | exploit |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-2852", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-03-25T16:30:34.040979Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-05T17:21:17.156Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T19:25:42.173Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-257776 | Tenda AC15 saveParentControlInfo stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.257776" }, { "name": "VDB-257776 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.257776" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/saveParentControlInfo_urls.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "AC15", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.20_multi" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "wxhwxhwxh_miemie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC15 15.03.20_multi. It has been declared as critical. This vulnerability affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257776. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "In Tenda AC15 15.03.20_multi wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Das betrifft die Funktion saveParentControlInfo der Datei /goform/saveParentControlInfo. Mit der Manipulation des Arguments urls mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-24T04:31:04.363Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-257776 | Tenda AC15 saveParentControlInfo stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.257776" }, { "name": "VDB-257776 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.257776" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/saveParentControlInfo_urls.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-23T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-23T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-23T06:52:11.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC15 saveParentControlInfo stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-2852", "datePublished": "2024-03-24T04:31:04.363Z", "dateReserved": "2024-03-23T05:46:57.422Z", "dateUpdated": "2024-08-01T19:25:42.173Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-16923
Vulnerability from cvelistv5
Published
2017-11-21 14:00
Modified
2024-09-17 03:14
Severity ?
EPSS score ?
Summary
Command Injection vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to execute arbitrary OS commands via a crafted cgi-bin/luci/usbeject?dev_name= GET request from the LAN. This occurs because the "sub_A6E8 usbeject_process_entry" function executes a system function with untrusted input.
References
▼ | URL | Tags |
---|---|---|
https://github.com/Iolop/Poc/tree/master/Router/Tenda | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T20:35:21.360Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/Iolop/Poc/tree/master/Router/Tenda" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Command Injection vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to execute arbitrary OS commands via a crafted cgi-bin/luci/usbeject?dev_name= GET request from the LAN. This occurs because the \"sub_A6E8 usbeject_process_entry\" function executes a system function with untrusted input." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2017-11-21T14:00:00Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/Iolop/Poc/tree/master/Router/Tenda" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2017-16923", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Command Injection vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to execute arbitrary OS commands via a crafted cgi-bin/luci/usbeject?dev_name= GET request from the LAN. This occurs because the \"sub_A6E8 usbeject_process_entry\" function executes a system function with untrusted input." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/Iolop/Poc/tree/master/Router/Tenda", "refsource": "MISC", "url": "https://github.com/Iolop/Poc/tree/master/Router/Tenda" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2017-16923", "datePublished": "2017-11-21T14:00:00Z", "dateReserved": "2017-11-21T00:00:00Z", "dateUpdated": "2024-09-17T03:14:10.141Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-2812
Vulnerability from cvelistv5
Published
2024-03-22 06:31
Modified
2024-08-01 19:25
Severity ?
6.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
6.3 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
6.3 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
EPSS score ?
Summary
A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been classified as critical. This affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257667. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.257667 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.257667 | signature, permissions-required | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formWriteFacMac.md | exploit |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-2812", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-03-22T18:03:05.827279Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-05T17:21:16.411Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T19:25:42.149Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-257667 | Tenda AC15 WriteFacMac formWriteFacMac os command injection", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.257667" }, { "name": "VDB-257667 | CTI Indicators (IOB, IOC, TTP, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.257667" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formWriteFacMac.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "AC15", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.05.18" }, { "status": "affected", "version": "15.03.20_multi" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_miemie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been classified as critical. This affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257667. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Es wurde eine Schwachstelle in Tenda AC15 15.03.05.18/15.03.20_multi ausgemacht. Sie wurde als kritisch eingestuft. Es geht dabei um die Funktion formWriteFacMac der Datei /goform/WriteFacMac. Durch die Manipulation des Arguments mac mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 6.5, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 OS Command Injection", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-22T06:31:04.518Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-257667 | Tenda AC15 WriteFacMac formWriteFacMac os command injection", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.257667" }, { "name": "VDB-257667 | CTI Indicators (IOB, IOC, TTP, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.257667" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formWriteFacMac.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-21T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-21T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-21T22:39:54.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC15 WriteFacMac formWriteFacMac os command injection" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-2812", "datePublished": "2024-03-22T06:31:04.518Z", "dateReserved": "2024-03-21T21:34:51.784Z", "dateUpdated": "2024-08-01T19:25:42.149Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-39673
Vulnerability from cvelistv5
Published
2023-08-18 00:00
Modified
2024-10-07 17:26
Severity ?
EPSS score ?
Summary
Tenda AC15 V1.0BR_V15.03.05.18_multi_TD01 was discovered to contain a buffer overflow via the function FUN_00010e34().
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T18:18:09.511Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.tendacn.com/download/list-3.html" }, { "tags": [ "x_transferred" ], "url": "https://github.com/Davidteeri/Bug-Report/blob/main/Tenda/AC15%20Impoper%20Input%20Validation.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac15:1.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0br_v15.03.05.18_multi_td01" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-39673", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-07T17:25:22.257636Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-07T17:26:35.553Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC15 V1.0BR_V15.03.05.18_multi_TD01 was discovered to contain a buffer overflow via the function FUN_00010e34()." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-18T02:44:55.717726", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://www.tendacn.com/download/list-3.html" }, { "url": "https://github.com/Davidteeri/Bug-Report/blob/main/Tenda/AC15%20Impoper%20Input%20Validation.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-39673", "datePublished": "2023-08-18T00:00:00", "dateReserved": "2023-08-07T00:00:00", "dateUpdated": "2024-10-07T17:26:35.553Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-18727
Vulnerability from cvelistv5
Published
2018-10-28 00:00
Modified
2024-08-05 11:16
Severity ?
EPSS score ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'deviceList' parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function.
References
▼ | URL | Tags |
---|---|---|
https://github.com/ZIllR0/Routers/blob/master/Tenda/stack1.md | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:16:00.390Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack1.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-10-27T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027deviceList\u0027 parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-10-28T00:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack1.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-18727", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027deviceList\u0027 parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack1.md", "refsource": "MISC", "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack1.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-18727", "datePublished": "2018-10-28T00:00:00", "dateReserved": "2018-10-27T00:00:00", "dateUpdated": "2024-08-05T11:16:00.390Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-2809
Vulnerability from cvelistv5
Published
2024-03-22 05:31
Modified
2024-08-01 20:52
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS score ?
Summary
A vulnerability, which was classified as critical, was found in Tenda AC15 15.03.05.18/15.03.20_multi. Affected is the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257664. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.257664 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.257664 | signature, permissions-required | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formSetFirewallCfg.md | exploit |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T19:25:42.167Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-257664 | Tenda AC15 SetFirewallCfg formSetFirewallCfg stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.257664" }, { "name": "VDB-257664 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.257664" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formSetFirewallCfg.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.18" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac15_firmware:15.03.20_multi:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.20_multi" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-2809", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-08-01T20:51:20.892981Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-01T20:52:37.087Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC15", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.05.18" }, { "status": "affected", "version": "15.03.20_multi" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_miemie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, was found in Tenda AC15 15.03.05.18/15.03.20_multi. Affected is the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257664. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Es wurde eine Schwachstelle in Tenda AC15 15.03.05.18/15.03.20_multi gefunden. Sie wurde als kritisch eingestuft. Betroffen hiervon ist die Funktion formSetFirewallCfg der Datei /goform/SetFirewallCfg. Dank der Manipulation des Arguments firewallEn mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-22T05:31:04.573Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-257664 | Tenda AC15 SetFirewallCfg formSetFirewallCfg stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.257664" }, { "name": "VDB-257664 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.257664" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formSetFirewallCfg.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-21T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-21T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-21T22:39:22.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC15 SetFirewallCfg formSetFirewallCfg stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-2809", "datePublished": "2024-03-22T05:31:04.573Z", "dateReserved": "2024-03-21T21:34:19.498Z", "dateUpdated": "2024-08-01T20:52:37.087Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-30376
Vulnerability from cvelistv5
Published
2023-04-24 00:00
Modified
2025-02-05 15:58
Severity ?
EPSS score ?
Summary
In Tenda AC15 V15.03.05.19, the function "henan_pppoe_user" contains a stack-based buffer overflow vulnerability.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T14:21:44.857Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/2205794866/Tenda/blob/main/AC15/9.md" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-30376", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T15:58:34.730706Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-05T15:58:56.980Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "In Tenda AC15 V15.03.05.19, the function \"henan_pppoe_user\" contains a stack-based buffer overflow vulnerability." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-24T00:00:00.000Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/2205794866/Tenda/blob/main/AC15/9.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-30376", "datePublished": "2023-04-24T00:00:00.000Z", "dateReserved": "2023-04-07T00:00:00.000Z", "dateUpdated": "2025-02-05T15:58:56.980Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-28556
Vulnerability from cvelistv5
Published
2022-05-04 15:13
Modified
2024-08-03 05:56
Severity ?
EPSS score ?
Summary
Tenda AC15 US_AC15V1.0BR_V15.03.05.20_multi_TDE01.bin is vulnerable to Buffer Overflow. The stack overflow vulnerability lies in the /goform/setpptpservercfg interface of the web. The sent post data startip and endip are copied to the stack using the sanf function, resulting in stack overflow. Similarly, this vulnerability can be used together with CVE-2021-44971
References
▼ | URL | Tags |
---|---|---|
https://github.com/doudoudedi/TendaAC15_vul/blob/main/TendaAC15-vul.md | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T05:56:15.568Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/doudoudedi/TendaAC15_vul/blob/main/TendaAC15-vul.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC15 US_AC15V1.0BR_V15.03.05.20_multi_TDE01.bin is vulnerable to Buffer Overflow. The stack overflow vulnerability lies in the /goform/setpptpservercfg interface of the web. The sent post data startip and endip are copied to the stack using the sanf function, resulting in stack overflow. Similarly, this vulnerability can be used together with CVE-2021-44971" } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-05-04T15:13:19", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/doudoudedi/TendaAC15_vul/blob/main/TendaAC15-vul.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2022-28556", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Tenda AC15 US_AC15V1.0BR_V15.03.05.20_multi_TDE01.bin is vulnerable to Buffer Overflow. The stack overflow vulnerability lies in the /goform/setpptpservercfg interface of the web. The sent post data startip and endip are copied to the stack using the sanf function, resulting in stack overflow. Similarly, this vulnerability can be used together with CVE-2021-44971" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/doudoudedi/TendaAC15_vul/blob/main/TendaAC15-vul.md", "refsource": "MISC", "url": "https://github.com/doudoudedi/TendaAC15_vul/blob/main/TendaAC15-vul.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-28556", "datePublished": "2022-05-04T15:13:19", "dateReserved": "2022-04-04T00:00:00", "dateUpdated": "2024-08-03T05:56:15.568Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-2807
Vulnerability from cvelistv5
Published
2024-03-22 04:31
Modified
2024-08-01 19:25
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS score ?
Summary
A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.20_multi. This vulnerability affects the function formExpandDlnaFile of the file /goform/expandDlnaFile. The manipulation of the argument filePath leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257662 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.257662 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.257662 | signature, permissions-required | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formExpandDlnaFile.md | exploit |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.18" }, { "status": "affected", "version": "15.03.20_multi" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-2807", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-03-25T16:38:21.385456Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-18T14:21:00.450Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T19:25:41.694Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-257662 | Tenda AC15 expandDlnaFile formExpandDlnaFile stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.257662" }, { "name": "VDB-257662 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.257662" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formExpandDlnaFile.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "AC15", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.05.18" }, { "status": "affected", "version": "15.03.20_multi" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_miemie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.20_multi. This vulnerability affects the function formExpandDlnaFile of the file /goform/expandDlnaFile. The manipulation of the argument filePath leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257662 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "In Tenda AC15 15.03.05.18/15.03.20_multi wurde eine Schwachstelle entdeckt. Sie wurde als kritisch eingestuft. Betroffen ist die Funktion formExpandDlnaFile der Datei /goform/expandDlnaFile. Durch das Beeinflussen des Arguments filePath mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-22T04:31:05.417Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-257662 | Tenda AC15 expandDlnaFile formExpandDlnaFile stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.257662" }, { "name": "VDB-257662 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.257662" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formExpandDlnaFile.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-21T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-21T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-21T22:38:57.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC15 expandDlnaFile formExpandDlnaFile stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-2807", "datePublished": "2024-03-22T04:31:05.417Z", "dateReserved": "2024-03-21T21:33:54.048Z", "dateUpdated": "2024-08-01T19:25:41.694Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-30369
Vulnerability from cvelistv5
Published
2023-04-24 00:00
Modified
2025-02-04 20:57
Severity ?
EPSS score ?
Summary
Tenda AC15 V15.03.05.19 is vulnerable to Buffer Overflow.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T14:21:44.818Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/2205794866/Tenda/blob/main/AC15/3.md" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-30369", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-04T20:57:03.323567Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-04T20:57:07.675Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC15 V15.03.05.19 is vulnerable to Buffer Overflow." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-24T00:00:00.000Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/2205794866/Tenda/blob/main/AC15/3.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-30369", "datePublished": "2023-04-24T00:00:00.000Z", "dateReserved": "2023-04-07T00:00:00.000Z", "dateUpdated": "2025-02-04T20:57:07.675Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-2850
Vulnerability from cvelistv5
Published
2024-03-24 02:00
Modified
2024-08-01 19:25
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS score ?
Summary
A vulnerability was found in Tenda AC15 15.03.05.18 and classified as critical. Affected by this issue is the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257774 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.257774 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.257774 | signature, permissions-required | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/saveParentControlInfo_urls.md | exploit |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.18" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-2850", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-07-08T13:55:57.303430Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-08T19:51:25.514Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T19:25:42.127Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-257774 | Tenda AC15 saveParentControlInfo stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.257774" }, { "name": "VDB-257774 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.257774" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/saveParentControlInfo_urls.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "AC15", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.05.18" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "wxhwxhwxh_miemie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC15 15.03.05.18 and classified as critical. Affected by this issue is the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257774 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Eine Schwachstelle wurde in Tenda AC15 15.03.05.18 gefunden. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion saveParentControlInfo der Datei /goform/saveParentControlInfo. Dank der Manipulation des Arguments urls mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-24T02:00:06.578Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-257774 | Tenda AC15 saveParentControlInfo stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.257774" }, { "name": "VDB-257774 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.257774" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/saveParentControlInfo_urls.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-23T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-23T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-23T06:51:53.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC15 saveParentControlInfo stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-2850", "datePublished": "2024-03-24T02:00:06.578Z", "dateReserved": "2024-03-23T05:46:47.272Z", "dateUpdated": "2024-08-01T19:25:42.127Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-2811
Vulnerability from cvelistv5
Published
2024-03-22 06:00
Modified
2024-08-21 22:53
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS score ?
Summary
A vulnerability was found in Tenda AC15 15.03.20_multi and classified as critical. Affected by this issue is the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257666 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.257666 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.257666 | signature, permissions-required | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formWifiWpsStart.md | exploit |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T19:25:41.889Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-257666 | Tenda AC15 WifiWpsStart formWifiWpsStart stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.257666" }, { "name": "VDB-257666 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.257666" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formWifiWpsStart.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac15_firmware:15.03.20_multi:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.20_multi" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-2811", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-03-27T13:55:59.253282Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-21T22:53:07.447Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC15", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.20_multi" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_miemie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC15 15.03.20_multi and classified as critical. Affected by this issue is the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257666 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Eine Schwachstelle wurde in Tenda AC15 15.03.20_multi gefunden. Sie wurde als kritisch eingestuft. Es geht hierbei um die Funktion formWifiWpsStart der Datei /goform/WifiWpsStart. Mit der Manipulation des Arguments index mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-22T06:00:07.629Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-257666 | Tenda AC15 WifiWpsStart formWifiWpsStart stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.257666" }, { "name": "VDB-257666 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.257666" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formWifiWpsStart.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-21T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-21T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-21T22:39:46.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC15 WifiWpsStart formWifiWpsStart stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-2811", "datePublished": "2024-03-22T06:00:07.629Z", "dateReserved": "2024-03-21T21:34:43.200Z", "dateUpdated": "2024-08-21T22:53:07.447Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-2817
Vulnerability from cvelistv5
Published
2024-03-22 08:00
Modified
2024-08-01 19:25
Severity ?
4.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N
4.3 (Medium) - CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N
4.3 (Medium) - CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N
EPSS score ?
Summary
A vulnerability, which was classified as problematic, has been found in Tenda AC15 15.03.05.18. Affected by this issue is the function fromSysToolRestoreSet of the file /goform/SysToolRestoreSet. The manipulation leads to cross-site request forgery. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257672. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.257672 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.257672 | signature, permissions-required | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/fromSysToolRestoreSet.md | exploit |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.18" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-2817", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-03-25T16:40:43.152598Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-18T14:17:33.913Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T19:25:41.819Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-257672 | Tenda AC15 SysToolRestoreSet fromSysToolRestoreSet cross-site request forgery", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.257672" }, { "name": "VDB-257672 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.257672" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/fromSysToolRestoreSet.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "AC15", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.05.18" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_tutu (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as problematic, has been found in Tenda AC15 15.03.05.18. Affected by this issue is the function fromSysToolRestoreSet of the file /goform/SysToolRestoreSet. The manipulation leads to cross-site request forgery. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257672. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Eine problematische Schwachstelle wurde in Tenda AC15 15.03.05.18 entdeckt. Dies betrifft die Funktion fromSysToolRestoreSet der Datei /goform/SysToolRestoreSet. Durch Manipulieren mit unbekannten Daten kann eine cross-site request forgery-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 5, "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-352", "description": "CWE-352 Cross-Site Request Forgery", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-22T08:00:06.270Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-257672 | Tenda AC15 SysToolRestoreSet fromSysToolRestoreSet cross-site request forgery", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.257672" }, { "name": "VDB-257672 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.257672" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/fromSysToolRestoreSet.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-21T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-21T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-21T22:40:26.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC15 SysToolRestoreSet fromSysToolRestoreSet cross-site request forgery" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-2817", "datePublished": "2024-03-22T08:00:06.270Z", "dateReserved": "2024-03-21T21:35:23.891Z", "dateUpdated": "2024-08-01T19:25:41.819Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-18708
Vulnerability from cvelistv5
Published
2018-10-27 22:00
Modified
2024-08-05 11:16
Severity ?
EPSS score ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "page" parameter of the function "fromAddressNat" for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.
References
▼ | URL | Tags |
---|---|---|
https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-05/Tenda.md | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:16:00.428Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-05/Tenda.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-10-27T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"page\" parameter of the function \"fromAddressNat\" for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-10-27T22:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-05/Tenda.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-18708", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"page\" parameter of the function \"fromAddressNat\" for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-05/Tenda.md", "refsource": "MISC", "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-05/Tenda.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-18708", "datePublished": "2018-10-27T22:00:00", "dateReserved": "2018-10-27T00:00:00", "dateUpdated": "2024-08-05T11:16:00.428Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-2851
Vulnerability from cvelistv5
Published
2024-03-24 03:00
Modified
2024-08-22 19:16
Severity ?
6.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
6.3 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
6.3 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
EPSS score ?
Summary
A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been classified as critical. This affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257775. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.257775 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.257775 | signature, permissions-required | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/formSetSambaConf.md | exploit |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T19:25:42.114Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-257775 | Tenda AC15 setsambacfg formSetSambaConf os command injection", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.257775" }, { "name": "VDB-257775 | CTI Indicators (IOB, IOC, TTP, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.257775" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/formSetSambaConf.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.18" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac15_firmware:15.03.05.20_multi:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.20_multi" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-2851", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-03-28T18:19:08.608418Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-22T19:16:03.727Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC15", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.05.18" }, { "status": "affected", "version": "15.03.20_multi" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "wxhwxhwxh_miemie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been classified as critical. This affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257775. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Es wurde eine Schwachstelle in Tenda AC15 15.03.05.18/15.03.20_multi ausgemacht. Sie wurde als kritisch eingestuft. Es betrifft die Funktion formSetSambaConf der Datei /goform/setsambacfg. Dank Manipulation des Arguments usbName mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 6.5, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 OS Command Injection", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-24T03:00:06.055Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-257775 | Tenda AC15 setsambacfg formSetSambaConf os command injection", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.257775" }, { "name": "VDB-257775 | CTI Indicators (IOB, IOC, TTP, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.257775" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/formSetSambaConf.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-23T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-23T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-23T06:51:59.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC15 setsambacfg formSetSambaConf os command injection" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-2851", "datePublished": "2024-03-24T03:00:06.055Z", "dateReserved": "2024-03-23T05:46:49.759Z", "dateUpdated": "2024-08-22T19:16:03.727Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-2814
Vulnerability from cvelistv5
Published
2024-03-22 07:00
Modified
2024-08-08 20:34
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS score ?
Summary
A vulnerability was found in Tenda AC15 15.03.20_multi. It has been rated as critical. This issue affects the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257669 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.257669 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.257669 | signature, permissions-required | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/fromDhcpListClient_page.md | exploit |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T19:25:42.195Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-257669 | Tenda AC15 DhcpListClient fromDhcpListClient stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.257669" }, { "name": "VDB-257669 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.257669" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/fromDhcpListClient_page.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac15_firmware:15.03.05.20_multi:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.20_multi" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-2814", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-08-08T20:33:21.558548Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-08T20:34:16.925Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC15", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.20_multi" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_miemie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC15 15.03.20_multi. It has been rated as critical. This issue affects the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257669 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Eine Schwachstelle wurde in Tenda AC15 15.03.20_multi ausgemacht. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion fromDhcpListClient der Datei /goform/DhcpListClient. Mittels dem Manipulieren des Arguments page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-22T07:00:07.402Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-257669 | Tenda AC15 DhcpListClient fromDhcpListClient stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.257669" }, { "name": "VDB-257669 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.257669" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/fromDhcpListClient_page.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-21T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-21T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-21T22:40:11.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC15 DhcpListClient fromDhcpListClient stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-2814", "datePublished": "2024-03-22T07:00:07.402Z", "dateReserved": "2024-03-21T21:35:08.751Z", "dateUpdated": "2024-08-08T20:34:16.925Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-10662
Vulnerability from cvelistv5
Published
2024-11-01 16:00
Modified
2024-11-05 15:25
Severity ?
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS score ?
Summary
A vulnerability was found in Tenda AC15 15.03.05.19 and classified as critical. This issue affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
References
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.282677 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.282677 | signature, permissions-required | |
https://vuldb.com/?submit.434933 | third-party-advisory | |
https://github.com/theRaz0r/iot-mycve/blob/main/tenda_ac15_stackflow_formSetDeviceName/tenda_ac15_stackflow_formSetDeviceName.md | exploit | |
https://www.tenda.com.cn/ | product |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.19" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-10662", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-11-01T19:06:25.331828Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-05T15:25:38.625Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC15", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.05.19" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "theRaz0r (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC15 15.03.05.19 and classified as critical. This issue affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "de", "value": "Eine kritische Schwachstelle wurde in Tenda AC15 15.03.05.19 gefunden. Dies betrifft die Funktion formSetDeviceName der Datei /goform/SetOnlineDevName. Durch Beeinflussen des Arguments devName mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-11-01T16:00:16.399Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-282677 | Tenda AC15 SetOnlineDevName formSetDeviceName stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.282677" }, { "name": "VDB-282677 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.282677" }, { "name": "Submit #434933 | Tenda AC15 V15.03.05.19 Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.434933" }, { "tags": [ "exploit" ], "url": "https://github.com/theRaz0r/iot-mycve/blob/main/tenda_ac15_stackflow_formSetDeviceName/tenda_ac15_stackflow_formSetDeviceName.md" }, { "tags": [ "product" ], "url": "https://www.tenda.com.cn/" } ], "timeline": [ { "lang": "en", "time": "2024-11-01T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-11-01T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-11-01T10:18:55.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC15 SetOnlineDevName formSetDeviceName stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-10662", "datePublished": "2024-11-01T16:00:16.399Z", "dateReserved": "2024-11-01T09:13:49.387Z", "dateUpdated": "2024-11-05T15:25:38.625Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-10987
Vulnerability from cvelistv5
Published
2020-07-13 18:46
Modified
2025-02-04 19:54
Severity ?
EPSS score ?
Summary
The goform/setUsbUnload endpoint of Tenda AC15 AC1900 version 15.03.05.19 allows remote attackers to execute arbitrary system commands via the deviceName POST parameter.
References
▼ | URL | Tags |
---|---|---|
https://www.ise.io/research/ | x_refsource_MISC | |
https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68 | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T11:21:14.161Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.ise.io/research/" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2020-10987", "options": [ { "Exploitation": "active" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-04T19:51:03.118238Z", "version": "2.0.3" }, "type": "ssvc" } }, { "other": { "content": { "dateAdded": "2021-11-03", "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?search_api_fulltext=CVE-2020-10987" }, "type": "kev" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-04T19:54:46.849Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "The goform/setUsbUnload endpoint of Tenda AC15 AC1900 version 15.03.05.19 allows remote attackers to execute arbitrary system commands via the deviceName POST parameter." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-07-13T18:46:12.000Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.ise.io/research/" }, { "tags": [ "x_refsource_MISC" ], "url": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-10987", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The goform/setUsbUnload endpoint of Tenda AC15 AC1900 version 15.03.05.19 allows remote attackers to execute arbitrary system commands via the deviceName POST parameter." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.ise.io/research/", "refsource": "MISC", "url": "https://www.ise.io/research/" }, { "name": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68", "refsource": "MISC", "url": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-10987", "datePublished": "2020-07-13T18:46:12.000Z", "dateReserved": "2020-03-26T00:00:00.000Z", "dateUpdated": "2025-02-04T19:54:46.849Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-2855
Vulnerability from cvelistv5
Published
2024-03-24 06:00
Modified
2024-08-01 19:25
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS score ?
Summary
A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.05.19/15.03.20. Affected by this vulnerability is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257779. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.257779 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.257779 | signature, permissions-required | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/fromSetSysTime.md | exploit |
Impacted products
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.18" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.19" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac15_firmware:15.03.20_multi:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.20_multi" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-2855", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-07-08T13:38:53.645813Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-08T19:51:14.751Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T19:25:42.153Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-257779 | Tenda AC15 SetSysTimeCfg fromSetSysTime stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.257779" }, { "name": "VDB-257779 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.257779" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/fromSetSysTime.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "AC15", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.05.18" }, { "status": "affected", "version": "15.03.05.19" }, { "status": "affected", "version": "15.03.20" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "wxhwxhwxh_miemie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.05.19/15.03.20. Affected by this vulnerability is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257779. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "In Tenda AC15 15.03.05.18/15.03.05.19/15.03.20 wurde eine kritische Schwachstelle entdeckt. Hierbei betrifft es die Funktion fromSetSysTime der Datei /goform/SetSysTimeCfg. Mittels dem Manipulieren des Arguments time mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-24T06:00:06.171Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-257779 | Tenda AC15 SetSysTimeCfg fromSetSysTime stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.257779" }, { "name": "VDB-257779 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.257779" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/fromSetSysTime.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-23T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-23T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-23T06:52:35.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC15 SetSysTimeCfg fromSetSysTime stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-2855", "datePublished": "2024-03-24T06:00:06.171Z", "dateReserved": "2024-03-23T05:47:33.356Z", "dateUpdated": "2024-08-01T19:25:42.153Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-43259
Vulnerability from cvelistv5
Published
2022-10-18 00:00
Modified
2024-08-03 13:26
Severity ?
EPSS score ?
Summary
Tenda AC15 V15.03.05.18 was discovered to contain a stack overflow via the timeZone parameter in the form_fast_setting_wifi_set function.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T13:26:02.811Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://drive.google.com/file/d/1VjYjZKv7MJ69hGPG-xD0xublUw-taq4w/view?usp=sharing" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC15 V15.03.05.18 was discovered to contain a stack overflow via the timeZone parameter in the form_fast_setting_wifi_set function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-10-18T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://drive.google.com/file/d/1VjYjZKv7MJ69hGPG-xD0xublUw-taq4w/view?usp=sharing" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-43259", "datePublished": "2022-10-18T00:00:00", "dateReserved": "2022-10-17T00:00:00", "dateUpdated": "2024-08-03T13:26:02.811Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-10280
Vulnerability from cvelistv5
Published
2024-10-23 13:31
Modified
2024-10-23 17:41
Severity ?
7.1 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
EPSS score ?
Summary
A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
References
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.281555 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.281555 | signature, permissions-required | |
https://vuldb.com/?submit.426417 | third-party-advisory | |
https://github.com/JohenanLi/router_vuls/blob/main/websReadEvent/websReadEvent.md | exploit | |
https://www.tenda.com.cn/ | product |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Tenda | AC6 |
Version: 20241022 |
||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac6_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac8_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "16.03.34.06" } ] }, { "cpes": [ "cpe:2.3:a:tenda:ac8_firmware:16.03.34.09:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac8_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "16.03.34.09" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "16.03.48.23" }, { "status": "affected", "version": "16.03.48.19" }, { "status": "affected", "version": "16.03.48.20" }, { "status": "affected", "version": "16.03.48.13" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac1206_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.42" }, { "status": "affected", "version": "15.03.05.19\\(6318_\\)" }, { "status": "affected", "version": "15.03.05.14" }, { "status": "affected", "version": "15.03.2.13" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac18_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.05" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\):*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac18_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.19\\(6318\\)" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac500_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "2.0.1.9\\(1307\\)" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac500_firmware:1.0.0.16:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac500_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0.0.16" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac500_firmware:1.0.0.14:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac500_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0.0.14" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.48:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10u_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.48" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10u_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.49" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.18" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.19" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-10280", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-10-23T17:28:19.760214Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-23T17:41:57.370Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC6", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC7", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC8", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC9", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC10", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC10U", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC15", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC18", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC500", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC1206", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "minipython (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "de", "value": "Eine Schwachstelle wurde in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 bis 20241022 ausgemacht. Sie wurde als problematisch eingestuft. Davon betroffen ist die Funktion websReadEvent der Datei /goform/GetIPTV. Durch Beeinflussen des Arguments Content-Length mit unbekannten Daten kann eine null pointer dereference-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 6.8, "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-476", "description": "NULL Pointer Dereference", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-10-23T13:31:07.315Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-281555 | Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.281555" }, { "name": "VDB-281555 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.281555" }, { "name": "Submit #426417 | Tenda AC8v4 V16.03.34.06 NULL Pointer Dereference", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.426417" }, { "tags": [ "exploit" ], "url": "https://github.com/JohenanLi/router_vuls/blob/main/websReadEvent/websReadEvent.md" }, { "tags": [ "product" ], "url": "https://www.tenda.com.cn/" } ], "timeline": [ { "lang": "en", "time": "2024-10-23T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-10-23T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-10-23T08:07:55.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-10280", "datePublished": "2024-10-23T13:31:07.315Z", "dateReserved": "2024-10-23T06:02:03.363Z", "dateUpdated": "2024-10-23T17:41:57.370Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-30373
Vulnerability from cvelistv5
Published
2023-04-24 00:00
Modified
2025-02-04 20:04
Severity ?
EPSS score ?
Summary
In Tenda AC15 V15.03.05.19, the function "xian_pppoe_user" contains a stack-based buffer overflow vulnerability.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T14:21:44.866Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/2205794866/Tenda/blob/main/AC15/8.md" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-30373", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-04T20:04:21.283148Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-04T20:04:58.541Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "references": [ { "tags": [ "exploit" ], "url": "https://github.com/Icathian-Rain/Tenda/blob/main/AC15/8.md" } ], "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "In Tenda AC15 V15.03.05.19, the function \"xian_pppoe_user\" contains a stack-based buffer overflow vulnerability." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-24T00:00:00.000Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/2205794866/Tenda/blob/main/AC15/8.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-30373", "datePublished": "2023-04-24T00:00:00.000Z", "dateReserved": "2023-04-07T00:00:00.000Z", "dateUpdated": "2025-02-04T20:04:58.541Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-30372
Vulnerability from cvelistv5
Published
2023-04-24 00:00
Modified
2025-02-04 20:06
Severity ?
EPSS score ?
Summary
In Tenda AC15 V15.03.05.19, The function "xkjs_ver32" contains a stack-based buffer overflow vulnerability.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T14:21:44.866Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/2205794866/Tenda/blob/main/AC15/10.md" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-30372", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-04T20:06:13.707929Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-04T20:06:20.104Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "references": [ { "tags": [ "exploit" ], "url": "https://github.com/Icathian-Rain/Tenda/blob/main/AC15/10.md" } ], "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "In Tenda AC15 V15.03.05.19, The function \"xkjs_ver32\" contains a stack-based buffer overflow vulnerability." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-24T00:00:00.000Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/2205794866/Tenda/blob/main/AC15/10.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-30372", "datePublished": "2023-04-24T00:00:00.000Z", "dateReserved": "2023-04-07T00:00:00.000Z", "dateUpdated": "2025-02-04T20:06:20.104Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-2806
Vulnerability from cvelistv5
Published
2024-03-22 04:31
Modified
2024-08-21 15:13
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS score ?
Summary
A vulnerability classified as critical has been found in Tenda AC15 15.03.05.18/15.03.20_multi. This affects the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceId/deviceMac leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257661 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.257661 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.257661 | signature, permissions-required | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/addWifiMacFilter_deviceId.md | exploit |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T19:25:41.898Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-257661 | Tenda AC15 addWifiMacFilter stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.257661" }, { "name": "VDB-257661 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.257661" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/addWifiMacFilter_deviceId.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.18" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac15_firmware:15.03.05.20_multi:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.20_multi" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-2806", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-08-21T15:10:50.792677Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-21T15:13:05.766Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC15", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.05.18" }, { "status": "affected", "version": "15.03.20_multi" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_miemie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability classified as critical has been found in Tenda AC15 15.03.05.18/15.03.20_multi. This affects the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceId/deviceMac leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257661 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Es wurde eine Schwachstelle in Tenda AC15 15.03.05.18/15.03.20_multi entdeckt. Sie wurde als kritisch eingestuft. Hiervon betroffen ist die Funktion addWifiMacFilter der Datei /goform/addWifiMacFilter. Durch Manipulieren des Arguments deviceId/deviceMac mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-22T04:31:04.089Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-257661 | Tenda AC15 addWifiMacFilter stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.257661" }, { "name": "VDB-257661 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.257661" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/addWifiMacFilter_deviceId.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-21T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-21T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-21T22:38:29.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC15 addWifiMacFilter stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-2806", "datePublished": "2024-03-22T04:31:04.089Z", "dateReserved": "2024-03-21T21:33:26.262Z", "dateUpdated": "2024-08-21T15:13:05.766Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-18729
Vulnerability from cvelistv5
Published
2018-10-28 00:00
Modified
2024-08-05 11:16
Severity ?
EPSS score ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a heap-based buffer overflow vulnerability in the router's web server -- httpd. While processing the 'mac' parameter for a post request, the value is directly used in a strcpy to a variable placed on the heap, which can leak sensitive information or even hijack program control flow.
References
▼ | URL | Tags |
---|---|---|
https://github.com/ZIllR0/Routers/blob/master/Tenda/heapoverflow1.md | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:16:00.404Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/heapoverflow1.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-10-27T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a heap-based buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027mac\u0027 parameter for a post request, the value is directly used in a strcpy to a variable placed on the heap, which can leak sensitive information or even hijack program control flow." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-10-28T00:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/heapoverflow1.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-18729", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a heap-based buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027mac\u0027 parameter for a post request, the value is directly used in a strcpy to a variable placed on the heap, which can leak sensitive information or even hijack program control flow." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/ZIllR0/Routers/blob/master/Tenda/heapoverflow1.md", "refsource": "MISC", "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/heapoverflow1.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-18729", "datePublished": "2018-10-28T00:00:00", "dateReserved": "2018-10-27T00:00:00", "dateUpdated": "2024-08-05T11:16:00.404Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-30370
Vulnerability from cvelistv5
Published
2023-04-24 00:00
Modified
2025-02-04 20:18
Severity ?
EPSS score ?
Summary
In Tenda AC15 V15.03.05.19, the function GetValue contains a stack-based buffer overflow vulnerability.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T14:21:44.863Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/2205794866/Tenda/blob/main/AC15/7.md" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-30370", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-04T20:18:13.041045Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-04T20:18:18.969Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "references": [ { "tags": [ "exploit" ], "url": "https://github.com/Icathian-Rain/Tenda/blob/main/AC15/7.md" } ], "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "In Tenda AC15 V15.03.05.19, the function GetValue contains a stack-based buffer overflow vulnerability." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-24T00:00:00.000Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/2205794866/Tenda/blob/main/AC15/7.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-30370", "datePublished": "2023-04-24T00:00:00.000Z", "dateReserved": "2023-04-07T00:00:00.000Z", "dateUpdated": "2025-02-04T20:18:18.969Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-44971
Vulnerability from cvelistv5
Published
2022-01-28 18:17
Modified
2024-08-04 04:32
Severity ?
EPSS score ?
Summary
Multiple Tenda devices are affected by authentication bypass, such as AC15V1.0 Firmware V15.03.05.20_multi?AC5V1.0 Firmware V15.03.06.48_multi and so on. an attacker can obtain sensitive information, and even combine it with authenticated command injection to implement RCE.
References
▼ | URL | Tags |
---|---|---|
http://tenda.com | x_refsource_MISC | |
http://ac15v10.com | x_refsource_MISC | |
https://github.com/21Gun5/my_cve/blob/main/tenda/bypass_auth.md | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:32:13.606Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://tenda.com" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://ac15v10.com" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/21Gun5/my_cve/blob/main/tenda/bypass_auth.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Multiple Tenda devices are affected by authentication bypass, such as AC15V1.0 Firmware V15.03.05.20_multi?AC5V1.0 Firmware V15.03.06.48_multi and so on. an attacker can obtain sensitive information, and even combine it with authenticated command injection to implement RCE." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-01-28T18:17:04", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "http://tenda.com" }, { "tags": [ "x_refsource_MISC" ], "url": "http://ac15v10.com" }, { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/21Gun5/my_cve/blob/main/tenda/bypass_auth.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-44971", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Multiple Tenda devices are affected by authentication bypass, such as AC15V1.0 Firmware V15.03.05.20_multi?AC5V1.0 Firmware V15.03.06.48_multi and so on. an attacker can obtain sensitive information, and even combine it with authenticated command injection to implement RCE." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "http://tenda.com", "refsource": "MISC", "url": "http://tenda.com" }, { "name": "http://ac15v10.com", "refsource": "MISC", "url": "http://ac15v10.com" }, { "name": "https://github.com/21Gun5/my_cve/blob/main/tenda/bypass_auth.md", "refsource": "MISC", "url": "https://github.com/21Gun5/my_cve/blob/main/tenda/bypass_auth.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-44971", "datePublished": "2022-01-28T18:17:04", "dateReserved": "2021-12-13T00:00:00", "dateUpdated": "2024-08-04T04:32:13.606Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-18731
Vulnerability from cvelistv5
Published
2018-10-28 00:00
Modified
2024-08-05 11:16
Severity ?
EPSS score ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'deviceMac' parameter for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.
References
▼ | URL | Tags |
---|---|---|
https://github.com/ZIllR0/Routers/blob/master/Tenda/stack4.md | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:16:00.376Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack4.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-10-27T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027deviceMac\u0027 parameter for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-10-28T00:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack4.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-18731", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027deviceMac\u0027 parameter for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack4.md", "refsource": "MISC", "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack4.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-18731", "datePublished": "2018-10-28T00:00:00", "dateReserved": "2018-10-27T00:00:00", "dateUpdated": "2024-08-05T11:16:00.376Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-2813
Vulnerability from cvelistv5
Published
2024-03-22 06:31
Modified
2024-08-23 20:28
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS score ?
Summary
A vulnerability was found in Tenda AC15 15.03.20_multi. It has been declared as critical. This vulnerability affects the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257668. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.257668 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.257668 | signature, permissions-required | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/form_fast_setting_wifi_set.md | exploit |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac15_firmware:15.03.05.20_multi:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.20_multi" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-2813", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-08-23T20:28:00.506212Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-23T20:28:09.491Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T19:25:41.881Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-257668 | Tenda AC15 fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.257668" }, { "name": "VDB-257668 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.257668" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/form_fast_setting_wifi_set.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "AC15", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.20_multi" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_miemie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC15 15.03.20_multi. It has been declared as critical. This vulnerability affects the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257668. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "In Tenda AC15 15.03.20_multi wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Dabei geht es um die Funktion form_fast_setting_wifi_set der Datei /goform/fast_setting_wifi_set. Durch Manipulation des Arguments ssid mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-22T06:31:05.875Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-257668 | Tenda AC15 fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.257668" }, { "name": "VDB-257668 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.257668" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/form_fast_setting_wifi_set.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-21T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-21T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-21T22:40:06.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC15 fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-2813", "datePublished": "2024-03-22T06:31:05.875Z", "dateReserved": "2024-03-21T21:35:03.729Z", "dateUpdated": "2024-08-23T20:28:09.491Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-30378
Vulnerability from cvelistv5
Published
2023-04-24 00:00
Modified
2025-02-05 15:57
Severity ?
EPSS score ?
Summary
In Tenda AC15 V15.03.05.19, the function "sub_8EE8" contains a stack-based buffer overflow vulnerability.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T14:21:44.779Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/2205794866/Tenda/blob/main/AC15/5.md" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-30378", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T15:57:40.673652Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-05T15:57:59.423Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "In Tenda AC15 V15.03.05.19, the function \"sub_8EE8\" contains a stack-based buffer overflow vulnerability." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-24T00:00:00.000Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/2205794866/Tenda/blob/main/AC15/5.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-30378", "datePublished": "2023-04-24T00:00:00.000Z", "dateReserved": "2023-04-07T00:00:00.000Z", "dateUpdated": "2025-02-05T15:57:59.423Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-2816
Vulnerability from cvelistv5
Published
2024-03-22 07:31
Modified
2024-08-21 15:06
Severity ?
4.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N
4.3 (Medium) - CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N
4.3 (Medium) - CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N
EPSS score ?
Summary
A vulnerability classified as problematic was found in Tenda AC15 15.03.05.18. Affected by this vulnerability is the function fromSysToolReboot of the file /goform/SysToolReboot. The manipulation leads to cross-site request forgery. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257671. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.257671 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.257671 | signature, permissions-required | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/fromSysToolReboot.md | exploit |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T19:25:41.890Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-257671 | Tenda AC15 SysToolReboot fromSysToolReboot cross-site request forgery", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.257671" }, { "name": "VDB-257671 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.257671" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/fromSysToolReboot.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.18" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-2816", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-08-21T15:05:26.052141Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-21T15:06:37.954Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC15", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.05.18" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_tutu (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability classified as problematic was found in Tenda AC15 15.03.05.18. Affected by this vulnerability is the function fromSysToolReboot of the file /goform/SysToolReboot. The manipulation leads to cross-site request forgery. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257671. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "In Tenda AC15 15.03.05.18 wurde eine problematische Schwachstelle entdeckt. Das betrifft die Funktion fromSysToolReboot der Datei /goform/SysToolReboot. Durch das Manipulieren mit unbekannten Daten kann eine cross-site request forgery-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 5, "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-352", "description": "CWE-352 Cross-Site Request Forgery", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-22T07:31:06.083Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-257671 | Tenda AC15 SysToolReboot fromSysToolReboot cross-site request forgery", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.257671" }, { "name": "VDB-257671 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.257671" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/fromSysToolReboot.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-21T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-21T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-21T22:40:21.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC15 SysToolReboot fromSysToolReboot cross-site request forgery" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-2816", "datePublished": "2024-03-22T07:31:06.083Z", "dateReserved": "2024-03-21T21:35:18.285Z", "dateUpdated": "2024-08-21T15:06:37.954Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-16936
Vulnerability from cvelistv5
Published
2017-11-24 07:00
Modified
2024-08-05 20:43
Severity ?
EPSS score ?
Summary
Directory Traversal vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to read arbitrary files via a cgi-bin/luci/request?op=1&path= URI that uses directory traversal sequences after a /usb/ substring.
References
▼ | URL | Tags |
---|---|---|
https://github.com/Iolop/Poc/tree/master/Router/Tenda | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T20:43:59.320Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/Iolop/Poc/tree/master/Router/Tenda" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2017-11-24T00:00:00", "descriptions": [ { "lang": "en", "value": "Directory Traversal vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to read arbitrary files via a cgi-bin/luci/request?op=1\u0026path= URI that uses directory traversal sequences after a /usb/ substring." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2017-11-24T07:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/Iolop/Poc/tree/master/Router/Tenda" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2017-16936", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Directory Traversal vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to read arbitrary files via a cgi-bin/luci/request?op=1\u0026path= URI that uses directory traversal sequences after a /usb/ substring." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/Iolop/Poc/tree/master/Router/Tenda", "refsource": "MISC", "url": "https://github.com/Iolop/Poc/tree/master/Router/Tenda" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2017-16936", "datePublished": "2017-11-24T07:00:00", "dateReserved": "2017-11-24T00:00:00", "dateUpdated": "2024-08-05T20:43:59.320Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-44167
Vulnerability from cvelistv5
Published
2022-11-21 00:00
Modified
2024-08-03 13:47
Severity ?
EPSS score ?
Summary
Tenda AC15 V15.03.05.18 is avulnerable to Buffer Overflow via function formSetPPTPServer.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T13:47:05.582Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://drive.google.com/file/d/1Jq8Tm_2FDS4WDD_afdhg1LnA3VcvZdjS/view?usp=sharing" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC15 V15.03.05.18 is avulnerable to Buffer Overflow via function formSetPPTPServer." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-11-21T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://drive.google.com/file/d/1Jq8Tm_2FDS4WDD_afdhg1LnA3VcvZdjS/view?usp=sharing" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-44167", "datePublished": "2022-11-21T00:00:00", "dateReserved": "2022-10-30T00:00:00", "dateUpdated": "2024-08-03T13:47:05.582Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-44169
Vulnerability from cvelistv5
Published
2022-11-21 00:00
Modified
2024-08-03 13:47
Severity ?
EPSS score ?
Summary
Tenda AC15 V15.03.05.18 is vulnerable to Buffer Overflow via function formSetVirtualSer.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T13:47:05.498Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/RobinWang825/IoT_vuln/tree/main/Tenda/AC15/formSetVirtualSer" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC15 V15.03.05.18 is vulnerable to Buffer Overflow via function formSetVirtualSer." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-11-21T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/RobinWang825/IoT_vuln/tree/main/Tenda/AC15/formSetVirtualSer" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-44169", "datePublished": "2022-11-21T00:00:00", "dateReserved": "2022-10-30T00:00:00", "dateUpdated": "2024-08-03T13:47:05.498Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-18728
Vulnerability from cvelistv5
Published
2018-10-28 00:00
Modified
2024-08-05 11:16
Severity ?
EPSS score ?
Summary
An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. They allow remote code execution via shell metacharacters in the usbName field to the __fastcall function with a POST request.
References
▼ | URL | Tags |
---|---|---|
https://github.com/ZIllR0/Routers/blob/master/Tenda/rce1.md | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:16:00.397Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/rce1.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-10-27T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. They allow remote code execution via shell metacharacters in the usbName field to the __fastcall function with a POST request." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-10-28T00:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/rce1.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-18728", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. They allow remote code execution via shell metacharacters in the usbName field to the __fastcall function with a POST request." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/ZIllR0/Routers/blob/master/Tenda/rce1.md", "refsource": "MISC", "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/rce1.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-18728", "datePublished": "2018-10-28T00:00:00", "dateReserved": "2018-10-27T00:00:00", "dateUpdated": "2024-08-05T11:16:00.397Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-18709
Vulnerability from cvelistv5
Published
2018-10-27 22:00
Modified
2024-08-05 11:16
Severity ?
EPSS score ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "firewallEn" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function.
References
▼ | URL | Tags |
---|---|---|
https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-08/Tenda.md | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:16:00.371Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-08/Tenda.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-10-27T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"firewallEn\" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-10-27T22:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-08/Tenda.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-18709", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"firewallEn\" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-08/Tenda.md", "refsource": "MISC", "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-08/Tenda.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-18709", "datePublished": "2018-10-27T22:00:00", "dateReserved": "2018-10-27T00:00:00", "dateUpdated": "2024-08-05T11:16:00.371Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-15916
Vulnerability from cvelistv5
Published
2020-07-23 17:53
Modified
2024-08-04 13:30
Severity ?
EPSS score ?
Summary
goform/AdvSetLanip endpoint on Tenda AC15 AC1900 15.03.05.19 devices allows remote attackers to execute arbitrary system commands via shell metacharacters in the lanIp POST parameter.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T13:30:22.771Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "goform/AdvSetLanip endpoint on Tenda AC15 AC1900 15.03.05.19 devices allows remote attackers to execute arbitrary system commands via shell metacharacters in the lanIp POST parameter." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-07-23T17:53:48", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-15916", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "goform/AdvSetLanip endpoint on Tenda AC15 AC1900 15.03.05.19 devices allows remote attackers to execute arbitrary system commands via shell metacharacters in the lanIp POST parameter." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68", "refsource": "MISC", "url": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-15916", "datePublished": "2020-07-23T17:53:48", "dateReserved": "2020-07-23T00:00:00", "dateUpdated": "2024-08-04T13:30:22.771Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-2805
Vulnerability from cvelistv5
Published
2024-03-22 03:00
Modified
2024-08-01 19:25
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS score ?
Summary
A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been rated as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257660. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.257660 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.257660 | signature, permissions-required | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/SetSpeedWan.md | exploit |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.18" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac15_firmware:15.03.20_multi:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.20_multi" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-2805", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-07-08T14:59:16.273514Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-08T19:52:43.903Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T19:25:42.139Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-257660 | Tenda AC15 SetSpeedWan formSetSpeedWan stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.257660" }, { "name": "VDB-257660 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.257660" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/SetSpeedWan.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "AC15", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.05.18" }, { "status": "affected", "version": "15.03.20_multi" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_miemie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been rated as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257660. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Eine kritische Schwachstelle wurde in Tenda AC15 15.03.05.18/15.03.20_multi ausgemacht. Davon betroffen ist die Funktion formSetSpeedWan der Datei /goform/SetSpeedWan. Durch das Manipulieren des Arguments speed_dir mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-22T03:00:06.426Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-257660 | Tenda AC15 SetSpeedWan formSetSpeedWan stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.257660" }, { "name": "VDB-257660 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.257660" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/SetSpeedWan.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-21T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-21T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-21T22:38:14.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC15 SetSpeedWan formSetSpeedWan stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-2805", "datePublished": "2024-03-22T03:00:06.426Z", "dateReserved": "2024-03-21T21:33:09.307Z", "dateUpdated": "2024-08-01T19:25:42.139Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-2810
Vulnerability from cvelistv5
Published
2024-03-22 05:31
Modified
2024-08-12 13:40
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS score ?
Summary
A vulnerability has been found in Tenda AC15 15.03.05.18/15.03.20_multi and classified as critical. Affected by this vulnerability is the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257665 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.257665 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.257665 | signature, permissions-required | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formWifiWpsOOB.md | exploit |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T19:25:42.171Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-257665 | Tenda AC15 WifiWpsOOB formWifiWpsOOB stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.257665" }, { "name": "VDB-257665 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.257665" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formWifiWpsOOB.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.18" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac15_firmware:15.03.20_multi:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.20_multi" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-2810", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-03-28T19:11:53.980346Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-12T13:40:03.316Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC15", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.05.18" }, { "status": "affected", "version": "15.03.20_multi" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_miemie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been found in Tenda AC15 15.03.05.18/15.03.20_multi and classified as critical. Affected by this vulnerability is the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257665 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "In Tenda AC15 15.03.05.18/15.03.20_multi wurde eine Schwachstelle gefunden. Sie wurde als kritisch eingestuft. Es geht um die Funktion formWifiWpsOOB der Datei /goform/WifiWpsOOB. Dank Manipulation des Arguments index mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-22T05:31:05.963Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-257665 | Tenda AC15 WifiWpsOOB formWifiWpsOOB stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.257665" }, { "name": "VDB-257665 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.257665" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formWifiWpsOOB.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-21T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-21T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-21T22:39:33.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC15 WifiWpsOOB formWifiWpsOOB stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-2810", "datePublished": "2024-03-22T05:31:05.963Z", "dateReserved": "2024-03-21T21:34:30.779Z", "dateUpdated": "2024-08-12T13:40:03.316Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-37175
Vulnerability from cvelistv5
Published
2022-08-19 20:50
Modified
2024-08-03 10:21
Severity ?
EPSS score ?
Summary
Tenda ac15 firmware V15.03.05.18 httpd server has stack buffer overflow in /goform/formWifiBasicSet.
References
▼ | URL | Tags |
---|---|---|
https://drive.google.com/file/d/16hshiCHS8j3YaFPkQD3xajVuwu_QVBe3/view | x_refsource_MISC | |
https://www.cnblogs.com/Amalll/p/16527552.html | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T10:21:33.226Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://drive.google.com/file/d/16hshiCHS8j3YaFPkQD3xajVuwu_QVBe3/view" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.cnblogs.com/Amalll/p/16527552.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda ac15 firmware V15.03.05.18 httpd server has stack buffer overflow in /goform/formWifiBasicSet." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-08-19T20:50:21", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://drive.google.com/file/d/16hshiCHS8j3YaFPkQD3xajVuwu_QVBe3/view" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.cnblogs.com/Amalll/p/16527552.html" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2022-37175", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Tenda ac15 firmware V15.03.05.18 httpd server has stack buffer overflow in /goform/formWifiBasicSet." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://drive.google.com/file/d/16hshiCHS8j3YaFPkQD3xajVuwu_QVBe3/view", "refsource": "MISC", "url": "https://drive.google.com/file/d/16hshiCHS8j3YaFPkQD3xajVuwu_QVBe3/view" }, { "name": "https://www.cnblogs.com/Amalll/p/16527552.html", "refsource": "MISC", "url": "https://www.cnblogs.com/Amalll/p/16527552.html" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-37175", "datePublished": "2022-08-19T20:50:21", "dateReserved": "2022-08-01T00:00:00", "dateUpdated": "2024-08-03T10:21:33.226Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-10661
Vulnerability from cvelistv5
Published
2024-11-01 16:00
Modified
2024-11-05 15:26
Severity ?
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS score ?
Summary
A vulnerability has been found in Tenda AC15 15.03.05.19 and classified as critical. This vulnerability affects the function SetDlnaCfg of the file /goform/SetDlnaCfg. The manipulation of the argument scanList leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
References
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.282676 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.282676 | signature, permissions-required | |
https://vuldb.com/?submit.434932 | third-party-advisory | |
https://github.com/theRaz0r/iot-mycve/blob/main/tenda_ac15_stackflow_formDLNAserver/tenda_ac15_stackflow_formDLNAserver.md | exploit | |
https://www.tenda.com.cn/ | product |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.19" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-10661", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-11-01T19:06:43.033160Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-05T15:26:23.637Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC15", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.05.19" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "theRaz0r (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been found in Tenda AC15 15.03.05.19 and classified as critical. This vulnerability affects the function SetDlnaCfg of the file /goform/SetDlnaCfg. The manipulation of the argument scanList leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "de", "value": "In Tenda AC15 15.03.05.19 wurde eine kritische Schwachstelle gefunden. Das betrifft die Funktion SetDlnaCfg der Datei /goform/SetDlnaCfg. Durch das Beeinflussen des Arguments scanList mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-11-01T16:00:13.148Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-282676 | Tenda AC15 SetDlnaCfg stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.282676" }, { "name": "VDB-282676 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.282676" }, { "name": "Submit #434932 | Tenda AC15 V15.03.05.19 Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.434932" }, { "tags": [ "exploit" ], "url": "https://github.com/theRaz0r/iot-mycve/blob/main/tenda_ac15_stackflow_formDLNAserver/tenda_ac15_stackflow_formDLNAserver.md" }, { "tags": [ "product" ], "url": "https://www.tenda.com.cn/" } ], "timeline": [ { "lang": "en", "time": "2024-11-01T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-11-01T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-11-01T10:18:54.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC15 SetDlnaCfg stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-10661", "datePublished": "2024-11-01T16:00:13.148Z", "dateReserved": "2024-11-01T09:13:46.982Z", "dateUpdated": "2024-11-05T15:26:23.637Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-2808
Vulnerability from cvelistv5
Published
2024-03-22 05:00
Modified
2024-08-12 13:41
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS score ?
Summary
A vulnerability, which was classified as critical, has been found in Tenda AC15 15.03.05.18/15.03.20_multi. This issue affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257663. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.257663 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.257663 | signature, permissions-required | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formQuickIndex.md | exploit |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T19:25:41.749Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-257663 | Tenda AC15 QuickIndex formQuickIndex stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.257663" }, { "name": "VDB-257663 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.257663" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formQuickIndex.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.18" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac15_firmware:15.03.20_multi:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.20_multi" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-2808", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-03-22T14:57:09.173805Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-12T13:41:45.486Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC15", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.05.18" }, { "status": "affected", "version": "15.03.20_multi" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_miemie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, has been found in Tenda AC15 15.03.05.18/15.03.20_multi. This issue affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257663. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Eine Schwachstelle wurde in Tenda AC15 15.03.05.18/15.03.20_multi entdeckt. Sie wurde als kritisch eingestuft. Betroffen davon ist die Funktion formQuickIndex der Datei /goform/QuickIndex. Durch Beeinflussen des Arguments PPPOEPassword mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-22T05:00:06.300Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-257663 | Tenda AC15 QuickIndex formQuickIndex stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.257663" }, { "name": "VDB-257663 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.257663" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formQuickIndex.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-21T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-21T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-21T22:39:09.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC15 QuickIndex formQuickIndex stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-2808", "datePublished": "2024-03-22T05:00:06.300Z", "dateReserved": "2024-03-21T21:34:07.034Z", "dateUpdated": "2024-08-12T13:41:45.486Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-18732
Vulnerability from cvelistv5
Published
2018-10-28 00:00
Modified
2024-08-05 11:16
Severity ?
EPSS score ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'ntpServer' parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function.
References
▼ | URL | Tags |
---|---|---|
https://github.com/ZIllR0/Routers/blob/master/Tenda/stack2.md | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:16:00.422Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack2.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-10-27T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027ntpServer\u0027 parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-10-28T00:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack2.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-18732", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027ntpServer\u0027 parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack2.md", "refsource": "MISC", "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack2.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-18732", "datePublished": "2018-10-28T00:00:00", "dateReserved": "2018-10-27T00:00:00", "dateUpdated": "2024-08-05T11:16:00.422Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-30375
Vulnerability from cvelistv5
Published
2023-04-24 00:00
Modified
2025-02-05 15:40
Severity ?
EPSS score ?
Summary
In Tenda AC15 V15.03.05.19, the function "getIfIp" contains a stack-based buffer overflow vulnerability.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T14:21:44.821Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/2205794866/Tenda/blob/main/AC15/1.md" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-30375", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T15:40:46.306819Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-05T15:40:50.746Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "In Tenda AC15 V15.03.05.19, the function \"getIfIp\" contains a stack-based buffer overflow vulnerability." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-24T00:00:00.000Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/2205794866/Tenda/blob/main/AC15/1.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-30375", "datePublished": "2023-04-24T00:00:00.000Z", "dateReserved": "2023-04-07T00:00:00.000Z", "dateUpdated": "2025-02-05T15:40:50.746Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-2815
Vulnerability from cvelistv5
Published
2024-03-22 07:31
Modified
2024-08-01 19:25
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS score ?
Summary
A vulnerability classified as critical has been found in Tenda AC15 15.03.20_multi. Affected is the function R7WebsSecurityHandler of the file /goform/execCommand of the component Cookie Handler. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257670 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.257670 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.257670 | signature, permissions-required | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/R7WebsSecurityHandler.md | exploit |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac15_firmware:15.03.20_multi:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.20_multi" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-2815", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-07-08T13:57:42.883520Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-08T19:51:33.522Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T19:25:42.123Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-257670 | Tenda AC15 Cookie execCommand R7WebsSecurityHandler stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.257670" }, { "name": "VDB-257670 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.257670" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/R7WebsSecurityHandler.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "modules": [ "Cookie Handler" ], "product": "AC15", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.20_multi" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_tutu (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability classified as critical has been found in Tenda AC15 15.03.20_multi. Affected is the function R7WebsSecurityHandler of the file /goform/execCommand of the component Cookie Handler. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257670 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Es wurde eine kritische Schwachstelle in Tenda AC15 15.03.20_multi entdeckt. Es betrifft die Funktion R7WebsSecurityHandler der Datei /goform/execCommand der Komponente Cookie Handler. Mittels Manipulieren des Arguments password mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-22T07:31:04.644Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-257670 | Tenda AC15 Cookie execCommand R7WebsSecurityHandler stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.257670" }, { "name": "VDB-257670 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.257670" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/R7WebsSecurityHandler.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-21T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-21T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-21T22:40:16.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC15 Cookie execCommand R7WebsSecurityHandler stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-2815", "datePublished": "2024-03-22T07:31:04.644Z", "dateReserved": "2024-03-21T21:35:13.502Z", "dateUpdated": "2024-08-01T19:25:42.123Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-36103
Vulnerability from cvelistv5
Published
2024-09-10 00:00
Modified
2024-09-10 19:19
Severity ?
EPSS score ?
Summary
Command Injection vulnerability in goform/SetIPTVCfg interface of Tenda AC15 V15.03.05.20 allows remote attackers to run arbitrary commands via crafted POST request.
References
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac15_firmware:15.03.05.20:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.20" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-36103", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-09-10T19:17:57.628118Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-77", "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-10T19:19:54.168Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Command Injection vulnerability in goform/SetIPTVCfg interface of Tenda AC15 V15.03.05.20 allows remote attackers to run arbitrary commands via crafted POST request." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-10T16:03:22.427612", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/t0hka1/Tenda-AC15-Exp/blob/master/Tenda%20AC15%20V15.03.05.20%20Exp.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-36103", "datePublished": "2024-09-10T00:00:00", "dateReserved": "2023-06-21T00:00:00", "dateUpdated": "2024-09-10T19:19:54.168Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-18730
Vulnerability from cvelistv5
Published
2018-10-28 00:00
Modified
2024-08-05 11:16
Severity ?
EPSS score ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'startIp' and 'endIp' parameters for a post request, each value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.
References
▼ | URL | Tags |
---|---|---|
https://github.com/ZIllR0/Routers/blob/master/Tenda/stack3.md | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:16:00.429Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack3.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-10-27T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027startIp\u0027 and \u0027endIp\u0027 parameters for a post request, each value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-10-28T00:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack3.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-18730", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027startIp\u0027 and \u0027endIp\u0027 parameters for a post request, each value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack3.md", "refsource": "MISC", "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack3.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-18730", "datePublished": "2018-10-28T00:00:00", "dateReserved": "2018-10-27T00:00:00", "dateUpdated": "2024-08-05T11:16:00.429Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-44156
Vulnerability from cvelistv5
Published
2022-11-21 00:00
Modified
2024-08-03 13:47
Severity ?
EPSS score ?
Summary
Tenda AC15 V15.03.05.19 is vulnerable to Buffer Overflow via function formSetIpMacBind.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T13:47:05.730Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://drive.google.com/file/d/1dbMwByl40uqMiSv_DOEW8pFjRhGX-j97/view?usp=sharing" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC15 V15.03.05.19 is vulnerable to Buffer Overflow via function formSetIpMacBind." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-11-21T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://drive.google.com/file/d/1dbMwByl40uqMiSv_DOEW8pFjRhGX-j97/view?usp=sharing" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-44156", "datePublished": "2022-11-21T00:00:00", "dateReserved": "2022-10-30T00:00:00", "dateUpdated": "2024-08-03T13:47:05.730Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-44168
Vulnerability from cvelistv5
Published
2022-11-21 00:00
Modified
2024-08-03 13:47
Severity ?
EPSS score ?
Summary
Tenda AC15 V15.03.05.18 is vulnerable to Buffer Overflow via function fromSetRouteStatic..
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T13:47:05.686Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/RobinWang825/IoT_vuln/tree/main/Tenda/AC15/fromSetRouteStatic" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC15 V15.03.05.18 is vulnerable to Buffer Overflow via function fromSetRouteStatic.." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-11-21T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/RobinWang825/IoT_vuln/tree/main/Tenda/AC15/fromSetRouteStatic" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-44168", "datePublished": "2022-11-21T00:00:00", "dateReserved": "2022-10-30T00:00:00", "dateUpdated": "2024-08-03T13:47:05.686Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-30371
Vulnerability from cvelistv5
Published
2023-04-24 00:00
Modified
2025-02-04 20:15
Severity ?
EPSS score ?
Summary
In Tenda AC15 V15.03.05.19, the function "sub_ED14" contains a stack-based buffer overflow vulnerability.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T14:21:44.798Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/2205794866/Tenda/blob/main/AC15/4.md" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-30371", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-04T20:07:48.350305Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-04T20:15:29.807Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "In Tenda AC15 V15.03.05.19, the function \"sub_ED14\" contains a stack-based buffer overflow vulnerability." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-24T00:00:00.000Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/2205794866/Tenda/blob/main/AC15/4.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-30371", "datePublished": "2023-04-24T00:00:00.000Z", "dateReserved": "2023-04-07T00:00:00.000Z", "dateUpdated": "2025-02-04T20:15:29.807Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-18706
Vulnerability from cvelistv5
Published
2018-10-27 22:00
Modified
2024-08-05 11:16
Severity ?
EPSS score ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "page" parameter of the function "fromDhcpListClient" for a request, it is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.
References
▼ | URL | Tags |
---|---|---|
https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-06/Tenda.md | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:16:00.389Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-06/Tenda.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-10-27T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"page\" parameter of the function \"fromDhcpListClient\" for a request, it is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-10-27T22:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-06/Tenda.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-18706", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"page\" parameter of the function \"fromDhcpListClient\" for a request, it is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-06/Tenda.md", "refsource": "MISC", "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-06/Tenda.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-18706", "datePublished": "2018-10-27T22:00:00", "dateReserved": "2018-10-27T00:00:00", "dateUpdated": "2024-08-05T11:16:00.389Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-18707
Vulnerability from cvelistv5
Published
2018-10-27 22:00
Modified
2024-08-05 11:16
Severity ?
EPSS score ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "ssid" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function.
References
▼ | URL | Tags |
---|---|---|
https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-07/Tenda.md | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:16:00.407Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-07/Tenda.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-10-27T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"ssid\" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-10-27T22:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-07/Tenda.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-18707", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"ssid\" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-07/Tenda.md", "refsource": "MISC", "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-07/Tenda.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-18707", "datePublished": "2018-10-27T22:00:00", "dateReserved": "2018-10-27T00:00:00", "dateUpdated": "2024-08-05T11:16:00.407Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-28557
Vulnerability from cvelistv5
Published
2022-05-04 15:18
Modified
2024-08-03 05:56
Severity ?
EPSS score ?
Summary
There is a command injection vulnerability at the /goform/setsambacfg interface of Tenda AC15 US_AC15V1.0BR_V15.03.05.20_multi_TDE01.bin device web, which can also cooperate with CVE-2021-44971 to cause unconditional arbitrary command execution
References
▼ | URL | Tags |
---|---|---|
https://github.com/doudoudedi/TendaAC15_vul/blob/main/TendaAC15-vul.md | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T05:56:15.648Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/doudoudedi/TendaAC15_vul/blob/main/TendaAC15-vul.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "There is a command injection vulnerability at the /goform/setsambacfg interface of Tenda AC15 US_AC15V1.0BR_V15.03.05.20_multi_TDE01.bin device web, which can also cooperate with CVE-2021-44971 to cause unconditional arbitrary command execution" } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-05-04T15:18:42", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/doudoudedi/TendaAC15_vul/blob/main/TendaAC15-vul.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2022-28557", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "There is a command injection vulnerability at the /goform/setsambacfg interface of Tenda AC15 US_AC15V1.0BR_V15.03.05.20_multi_TDE01.bin device web, which can also cooperate with CVE-2021-44971 to cause unconditional arbitrary command execution" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/doudoudedi/TendaAC15_vul/blob/main/TendaAC15-vul.md", "refsource": "MISC", "url": "https://github.com/doudoudedi/TendaAC15_vul/blob/main/TendaAC15-vul.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-28557", "datePublished": "2022-05-04T15:18:42", "dateReserved": "2022-04-04T00:00:00", "dateUpdated": "2024-08-03T05:56:15.648Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-10988
Vulnerability from cvelistv5
Published
2020-07-13 18:01
Modified
2024-08-04 11:21
Severity ?
EPSS score ?
Summary
A hard-coded telnet credential in the tenda_login binary of Tenda AC15 AC1900 version 15.03.05.19 allows unauthenticated remote attackers to start a telnetd service on the device.
References
▼ | URL | Tags |
---|---|---|
https://www.ise.io/research/ | x_refsource_MISC | |
https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68 | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T11:21:14.383Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.ise.io/research/" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A hard-coded telnet credential in the tenda_login binary of Tenda AC15 AC1900 version 15.03.05.19 allows unauthenticated remote attackers to start a telnetd service on the device." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-07-13T18:01:55", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.ise.io/research/" }, { "tags": [ "x_refsource_MISC" ], "url": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-10988", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A hard-coded telnet credential in the tenda_login binary of Tenda AC15 AC1900 version 15.03.05.19 allows unauthenticated remote attackers to start a telnetd service on the device." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.ise.io/research/", "refsource": "MISC", "url": "https://www.ise.io/research/" }, { "name": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68", "refsource": "MISC", "url": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-10988", "datePublished": "2020-07-13T18:01:55", "dateReserved": "2020-03-26T00:00:00", "dateUpdated": "2024-08-04T11:21:14.383Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }