Vulnerabilites related to tenda - ac11
var-202105-1129
Vulnerability from variot
An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /goform/setportList allows attackers to execute arbitrary code on the system via a crafted post request. Tenda AC11 The device contains an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Tenda AC11 is an AC1200 dual-band Gigabit WiFi router
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202105-1129", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac11", "scope": "lte", "trust": 1.0, "vendor": "tenda", "version": "02.03.01.104_cn" }, { "model": "ac11", "scope": "lte", "trust": 0.8, "vendor": "tenda", "version": "ac11 firmware 02.03.01.104_cn until" }, { "model": "ac11", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac11 \u003c=02.03.01.104 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-33999" }, { "db": "JVNDB", "id": "JVNDB-2021-006373" }, { "db": "NVD", "id": "CVE-2021-31758" } ] }, "cve": "CVE-2021-31758", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CVE-2021-31758", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2021-33999", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2021-31758", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-31758", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-31758", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2021-31758", "trust": 0.8, "value": "Critical" }, { "author": "CNVD", "id": "CNVD-2021-33999", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202105-384", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-31758", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-33999" }, { "db": "VULMON", "id": "CVE-2021-31758" }, { "db": "JVNDB", "id": "JVNDB-2021-006373" }, { "db": "CNNVD", "id": "CNNVD-202105-384" }, { "db": "NVD", "id": "CVE-2021-31758" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /goform/setportList allows attackers to execute arbitrary code on the system via a crafted post request. Tenda AC11 The device contains an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Tenda AC11 is an AC1200 dual-band Gigabit WiFi router", "sources": [ { "db": "NVD", "id": "CVE-2021-31758" }, { "db": "JVNDB", "id": "JVNDB-2021-006373" }, { "db": "CNVD", "id": "CNVD-2021-33999" }, { "db": "VULMON", "id": "CVE-2021-31758" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-31758", "trust": 3.9 }, { "db": "JVNDB", "id": "JVNDB-2021-006373", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-33999", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202105-384", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-31758", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-33999" }, { "db": "VULMON", "id": "CVE-2021-31758" }, { "db": "JVNDB", "id": "JVNDB-2021-006373" }, { "db": "CNNVD", "id": "CNNVD-202105-384" }, { "db": "NVD", "id": "CVE-2021-31758" } ] }, "id": "VAR-202105-1129", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-33999" } ], "trust": 1.6 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-33999" } ] }, "last_update_date": "2024-08-14T14:11:23.142000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top\u00a0Page", "trust": 0.8, "url": "https://www.tendacn.com/en/default.html" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-006373" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-006373" }, { "db": "NVD", "id": "CVE-2021-31758" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.1, "url": "https://github.com/yu3h0/iot_cve/tree/main/tenda/cve_2" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-31758" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/787.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-33999" }, { "db": "VULMON", "id": "CVE-2021-31758" }, { "db": "JVNDB", "id": "JVNDB-2021-006373" }, { "db": "CNNVD", "id": "CNNVD-202105-384" }, { "db": "NVD", "id": "CVE-2021-31758" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-33999" }, { "db": "VULMON", "id": "CVE-2021-31758" }, { "db": "JVNDB", "id": "JVNDB-2021-006373" }, { "db": "CNNVD", "id": "CNNVD-202105-384" }, { "db": "NVD", "id": "CVE-2021-31758" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-05-11T00:00:00", "db": "CNVD", "id": "CNVD-2021-33999" }, { "date": "2021-05-07T00:00:00", "db": "VULMON", "id": "CVE-2021-31758" }, { "date": "2022-01-06T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-006373" }, { "date": "2021-05-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202105-384" }, { "date": "2021-05-07T23:15:07.137000", "db": "NVD", "id": "CVE-2021-31758" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-05-11T00:00:00", "db": "CNVD", "id": "CNVD-2021-33999" }, { "date": "2021-05-10T00:00:00", "db": "VULMON", "id": "CVE-2021-31758" }, { "date": "2022-01-06T00:57:00", "db": "JVNDB", "id": "JVNDB-2021-006373" }, { "date": "2021-05-11T00:00:00", "db": "CNNVD", "id": "CNNVD-202105-384" }, { "date": "2021-05-10T14:56:14.180000", "db": "NVD", "id": "CVE-2021-31758" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202105-384" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda\u00a0AC11\u00a0 Out-of-bounds write vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-006373" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202105-384" } ], "trust": 0.6 } }
var-202202-1054
Vulnerability from variot
Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer overflow in the wifiBasicCfg module. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data. Tenda AC series router AC11 Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC11 is a router from the Chinese company Tenda
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202202-1054", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac11", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "02.03.01.104_cn" }, { "model": "ac11", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac11 firmware 02.03.01.104_cn" }, { "model": "ac11", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac series router ac11 v02.03.01.104 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-15164" }, { "db": "JVNDB", "id": "JVNDB-2022-004916" }, { "db": "NVD", "id": "CVE-2021-46321" } ] }, "cve": "CVE-2021-46321", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2021-46321", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CNVD-2022-15164", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2021-46321", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-46321", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-46321", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2021-46321", "trust": 0.8, "value": "Critical" }, { "author": "CNVD", "id": "CNVD-2022-15164", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202202-1302", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-15164" }, { "db": "JVNDB", "id": "JVNDB-2022-004916" }, { "db": "CNNVD", "id": "CNNVD-202202-1302" }, { "db": "NVD", "id": "CVE-2021-46321" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer overflow in the wifiBasicCfg module. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data. Tenda AC series router AC11 Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC11 is a router from the Chinese company Tenda", "sources": [ { "db": "NVD", "id": "CVE-2021-46321" }, { "db": "JVNDB", "id": "JVNDB-2022-004916" }, { "db": "CNVD", "id": "CNVD-2022-15164" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-46321", "trust": 3.8 }, { "db": "JVNDB", "id": "JVNDB-2022-004916", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2022-15164", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202202-1302", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-15164" }, { "db": "JVNDB", "id": "JVNDB-2022-004916" }, { "db": "CNNVD", "id": "CNNVD-202202-1302" }, { "db": "NVD", "id": "CVE-2021-46321" } ] }, "id": "VAR-202202-1054", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2022-15164" } ], "trust": 1.6 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-15164" } ] }, "last_update_date": "2024-11-23T21:33:10.870000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top\u00a0Page", "trust": 0.8, "url": "https://www.tendacn.com/default.html" }, { "title": "Patch for Tenda AC Series Router Buffer Overflow Vulnerability (CNVD-2022-15164)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/322291" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-15164" }, { "db": "JVNDB", "id": "JVNDB-2022-004916" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-004916" }, { "db": "NVD", "id": "CVE-2021-46321" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://github.com/ainevsia/cve-request/tree/main/tenda/15" }, { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-46321" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-15164" }, { "db": "JVNDB", "id": "JVNDB-2022-004916" }, { "db": "CNNVD", "id": "CNNVD-202202-1302" }, { "db": "NVD", "id": "CVE-2021-46321" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2022-15164" }, { "db": "JVNDB", "id": "JVNDB-2022-004916" }, { "db": "CNNVD", "id": "CNNVD-202202-1302" }, { "db": "NVD", "id": "CVE-2021-46321" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-02-27T00:00:00", "db": "CNVD", "id": "CNVD-2022-15164" }, { "date": "2023-05-11T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-004916" }, { "date": "2022-02-15T00:00:00", "db": "CNNVD", "id": "CNNVD-202202-1302" }, { "date": "2022-02-15T20:15:07.770000", "db": "NVD", "id": "CVE-2021-46321" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-02-27T00:00:00", "db": "CNVD", "id": "CNVD-2022-15164" }, { "date": "2023-05-11T05:47:00", "db": "JVNDB", "id": "JVNDB-2022-004916" }, { "date": "2022-03-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202202-1302" }, { "date": "2024-11-21T06:33:52.760000", "db": "NVD", "id": "CVE-2021-46321" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202202-1302" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda\u00a0AC\u00a0 series router \u00a0AC11\u00a0 Out-of-bounds write vulnerability in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-004916" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202202-1302" } ], "trust": 0.6 } }
var-202105-1127
Vulnerability from variot
An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /gofrom/setwanType allows attackers to execute arbitrary code on the system via a crafted post request. This occurs when input vector controlled by malicious attack get copied to the stack variable. Tenda AC11 The device contains an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Tenda AC11 is an AC1200 dual-band Gigabit WiFi router
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202105-1127", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac11", "scope": "lte", "trust": 1.0, "vendor": "tenda", "version": "02.03.01.104_cn" }, { "model": "ac11", "scope": "lte", "trust": 0.8, "vendor": "tenda", "version": "ac11 firmware 02.03.01.104_cn until" }, { "model": "ac11", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac11 \u003c=02.03.01.104 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-33997" }, { "db": "JVNDB", "id": "JVNDB-2021-006371" }, { "db": "NVD", "id": "CVE-2021-31756" } ] }, "cve": "CVE-2021-31756", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CVE-2021-31756", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2021-33997", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2021-31756", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-31756", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-31756", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2021-31756", "trust": 0.8, "value": "Critical" }, { "author": "CNVD", "id": "CNVD-2021-33997", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202105-381", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-31756", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-33997" }, { "db": "VULMON", "id": "CVE-2021-31756" }, { "db": "JVNDB", "id": "JVNDB-2021-006371" }, { "db": "CNNVD", "id": "CNNVD-202105-381" }, { "db": "NVD", "id": "CVE-2021-31756" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /gofrom/setwanType allows attackers to execute arbitrary code on the system via a crafted post request. This occurs when input vector controlled by malicious attack get copied to the stack variable. Tenda AC11 The device contains an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Tenda AC11 is an AC1200 dual-band Gigabit WiFi router", "sources": [ { "db": "NVD", "id": "CVE-2021-31756" }, { "db": "JVNDB", "id": "JVNDB-2021-006371" }, { "db": "CNVD", "id": "CNVD-2021-33997" }, { "db": "VULMON", "id": "CVE-2021-31756" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-31756", "trust": 3.9 }, { "db": "JVNDB", "id": "JVNDB-2021-006371", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-33997", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202105-381", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-31756", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-33997" }, { "db": "VULMON", "id": "CVE-2021-31756" }, { "db": "JVNDB", "id": "JVNDB-2021-006371" }, { "db": "CNNVD", "id": "CNNVD-202105-381" }, { "db": "NVD", "id": "CVE-2021-31756" } ] }, "id": "VAR-202105-1127", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-33997" } ], "trust": 1.6 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-33997" } ] }, "last_update_date": "2024-08-14T14:50:15.594000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top\u00a0Page", "trust": 0.8, "url": "https://www.tendacn.com/en/default.html" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-006371" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-006371" }, { "db": "NVD", "id": "CVE-2021-31756" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.1, "url": "https://github.com/yu3h0/iot_cve/tree/main/tenda/cve_1" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-31756" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/787.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-33997" }, { "db": "VULMON", "id": "CVE-2021-31756" }, { "db": "JVNDB", "id": "JVNDB-2021-006371" }, { "db": "CNNVD", "id": "CNNVD-202105-381" }, { "db": "NVD", "id": "CVE-2021-31756" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-33997" }, { "db": "VULMON", "id": "CVE-2021-31756" }, { "db": "JVNDB", "id": "JVNDB-2021-006371" }, { "db": "CNNVD", "id": "CNNVD-202105-381" }, { "db": "NVD", "id": "CVE-2021-31756" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-05-11T00:00:00", "db": "CNVD", "id": "CNVD-2021-33997" }, { "date": "2021-05-07T00:00:00", "db": "VULMON", "id": "CVE-2021-31756" }, { "date": "2022-01-06T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-006371" }, { "date": "2021-05-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202105-381" }, { "date": "2021-05-07T23:15:07.077000", "db": "NVD", "id": "CVE-2021-31756" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-05-11T00:00:00", "db": "CNVD", "id": "CNVD-2021-33997" }, { "date": "2021-05-10T00:00:00", "db": "VULMON", "id": "CVE-2021-31756" }, { "date": "2022-01-06T00:57:00", "db": "JVNDB", "id": "JVNDB-2021-006371" }, { "date": "2021-05-11T00:00:00", "db": "CNNVD", "id": "CNNVD-202105-381" }, { "date": "2021-05-10T14:56:53.623000", "db": "NVD", "id": "CVE-2021-31756" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202105-381" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda\u00a0AC11\u00a0 Out-of-bounds write vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-006371" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202105-381" } ], "trust": 0.6 } }
var-202202-1736
Vulnerability from variot
Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer overflow in the onlineList module. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data. Tenda AC series router AC11 Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC11 is a router from the Chinese company Tenda
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202202-1736", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac11", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "02.03.01.104_cn" }, { "model": "ac11", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac11 firmware 02.03.01.104_cn" }, { "model": "ac11", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac series router ac11 v02.03.01.104 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-15167" }, { "db": "JVNDB", "id": "JVNDB-2022-004960" }, { "db": "NVD", "id": "CVE-2021-46264" } ] }, "cve": "CVE-2021-46264", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2021-46264", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CNVD-2022-15167", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2021-46264", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-46264", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-46264", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2021-46264", "trust": 0.8, "value": "Critical" }, { "author": "CNVD", "id": "CNVD-2022-15167", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202202-1297", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-15167" }, { "db": "JVNDB", "id": "JVNDB-2022-004960" }, { "db": "CNNVD", "id": "CNNVD-202202-1297" }, { "db": "NVD", "id": "CVE-2021-46264" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer overflow in the onlineList module. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data. Tenda AC series router AC11 Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC11 is a router from the Chinese company Tenda", "sources": [ { "db": "NVD", "id": "CVE-2021-46264" }, { "db": "JVNDB", "id": "JVNDB-2022-004960" }, { "db": "CNVD", "id": "CNVD-2022-15167" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-46264", "trust": 3.8 }, { "db": "JVNDB", "id": "JVNDB-2022-004960", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2022-15167", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202202-1297", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-15167" }, { "db": "JVNDB", "id": "JVNDB-2022-004960" }, { "db": "CNNVD", "id": "CNNVD-202202-1297" }, { "db": "NVD", "id": "CVE-2021-46264" } ] }, "id": "VAR-202202-1736", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2022-15167" } ], "trust": 1.6 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-15167" } ] }, "last_update_date": "2024-11-23T22:15:55.672000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top\u00a0Page", "trust": 0.8, "url": "https://www.tendacn.com/default.html" }, { "title": "Patch for Tenda AC Series Router Buffer Overflow Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/322276" }, { "title": "Tenda AC Buffer error vulnerability fix", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=183452" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-15167" }, { "db": "JVNDB", "id": "JVNDB-2022-004960" }, { "db": "CNNVD", "id": "CNNVD-202202-1297" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-004960" }, { "db": "NVD", "id": "CVE-2021-46264" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://github.com/ainevsia/cve-request/tree/main/tenda/9" }, { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-46264" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-15167" }, { "db": "JVNDB", "id": "JVNDB-2022-004960" }, { "db": "CNNVD", "id": "CNNVD-202202-1297" }, { "db": "NVD", "id": "CVE-2021-46264" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2022-15167" }, { "db": "JVNDB", "id": "JVNDB-2022-004960" }, { "db": "CNNVD", "id": "CNNVD-202202-1297" }, { "db": "NVD", "id": "CVE-2021-46264" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-02-27T00:00:00", "db": "CNVD", "id": "CNVD-2022-15167" }, { "date": "2023-05-12T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-004960" }, { "date": "2022-02-15T00:00:00", "db": "CNNVD", "id": "CNNVD-202202-1297" }, { "date": "2022-02-15T20:15:07.650000", "db": "NVD", "id": "CVE-2021-46264" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-02-27T00:00:00", "db": "CNVD", "id": "CNVD-2022-15167" }, { "date": "2023-05-12T03:35:00", "db": "JVNDB", "id": "JVNDB-2022-004960" }, { "date": "2022-03-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202202-1297" }, { "date": "2024-11-21T06:33:50.190000", "db": "NVD", "id": "CVE-2021-46264" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202202-1297" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda\u00a0AC\u00a0 series router \u00a0AC11\u00a0 Out-of-bounds write vulnerability in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-004960" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202202-1297" } ], "trust": 0.6 } }
var-202105-1128
Vulnerability from variot
An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /goform/setVLAN allows attackers to execute arbitrary code on the system via a crafted post request. Tenda AC11 The device contains an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Tenda AC11 is an AC1200 dual-band Gigabit WiFi router
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202105-1128", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac11", "scope": "lte", "trust": 1.0, "vendor": "tenda", "version": "02.03.01.104_cn" }, { "model": "ac11", "scope": "lte", "trust": 0.8, "vendor": "tenda", "version": "ac11 firmware 02.03.01.104_cn until" }, { "model": "ac11", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac11 \u003c=02.03.01.104 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-34000" }, { "db": "JVNDB", "id": "JVNDB-2021-006372" }, { "db": "NVD", "id": "CVE-2021-31757" } ] }, "cve": "CVE-2021-31757", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CVE-2021-31757", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2021-34000", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2021-31757", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-31757", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-31757", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2021-31757", "trust": 0.8, "value": "Critical" }, { "author": "CNVD", "id": "CNVD-2021-34000", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202105-382", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-31757", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-34000" }, { "db": "VULMON", "id": "CVE-2021-31757" }, { "db": "JVNDB", "id": "JVNDB-2021-006372" }, { "db": "CNNVD", "id": "CNNVD-202105-382" }, { "db": "NVD", "id": "CVE-2021-31757" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /goform/setVLAN allows attackers to execute arbitrary code on the system via a crafted post request. Tenda AC11 The device contains an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Tenda AC11 is an AC1200 dual-band Gigabit WiFi router", "sources": [ { "db": "NVD", "id": "CVE-2021-31757" }, { "db": "JVNDB", "id": "JVNDB-2021-006372" }, { "db": "CNVD", "id": "CNVD-2021-34000" }, { "db": "VULMON", "id": "CVE-2021-31757" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-31757", "trust": 3.9 }, { "db": "JVNDB", "id": "JVNDB-2021-006372", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-34000", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202105-382", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-31757", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-34000" }, { "db": "VULMON", "id": "CVE-2021-31757" }, { "db": "JVNDB", "id": "JVNDB-2021-006372" }, { "db": "CNNVD", "id": "CNNVD-202105-382" }, { "db": "NVD", "id": "CVE-2021-31757" } ] }, "id": "VAR-202105-1128", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-34000" } ], "trust": 1.6 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-34000" } ] }, "last_update_date": "2024-08-14T15:01:28.477000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top\u00a0Page", "trust": 0.8, "url": "https://www.tendacn.com/en/default.html" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-006372" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-006372" }, { "db": "NVD", "id": "CVE-2021-31757" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.1, "url": "https://github.com/yu3h0/iot_cve/tree/main/tenda/cve_4" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-31757" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/787.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-34000" }, { "db": "VULMON", "id": "CVE-2021-31757" }, { "db": "JVNDB", "id": "JVNDB-2021-006372" }, { "db": "CNNVD", "id": "CNNVD-202105-382" }, { "db": "NVD", "id": "CVE-2021-31757" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-34000" }, { "db": "VULMON", "id": "CVE-2021-31757" }, { "db": "JVNDB", "id": "JVNDB-2021-006372" }, { "db": "CNNVD", "id": "CNNVD-202105-382" }, { "db": "NVD", "id": "CVE-2021-31757" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-05-11T00:00:00", "db": "CNVD", "id": "CNVD-2021-34000" }, { "date": "2021-05-07T00:00:00", "db": "VULMON", "id": "CVE-2021-31757" }, { "date": "2022-01-06T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-006372" }, { "date": "2021-05-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202105-382" }, { "date": "2021-05-07T23:15:07.107000", "db": "NVD", "id": "CVE-2021-31757" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-05-11T00:00:00", "db": "CNVD", "id": "CNVD-2021-34000" }, { "date": "2021-05-10T00:00:00", "db": "VULMON", "id": "CVE-2021-31757" }, { "date": "2022-01-06T00:57:00", "db": "JVNDB", "id": "JVNDB-2021-006372" }, { "date": "2021-05-11T00:00:00", "db": "CNNVD", "id": "CNNVD-202105-382" }, { "date": "2021-05-10T14:56:36.647000", "db": "NVD", "id": "CVE-2021-31757" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202105-382" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda\u00a0AC11\u00a0 Out-of-bounds write vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-006372" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202105-382" } ], "trust": 0.6 } }
var-202202-1055
Vulnerability from variot
Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer overflow in the wifiTime module. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data. Tenda AC series router AC11 Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC11 is a router from the Chinese company Tenda
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202202-1055", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac11", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "02.03.01.104_cn" }, { "model": "ac11", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac11 firmware 02.03.01.104_cn" }, { "model": "ac11", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac series router ac11 v02.03.01.104 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-15163" }, { "db": "JVNDB", "id": "JVNDB-2022-004961" }, { "db": "NVD", "id": "CVE-2021-46263" } ] }, "cve": "CVE-2021-46263", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2021-46263", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CNVD-2022-15163", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2021-46263", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-46263", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-46263", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2021-46263", "trust": 0.8, "value": "Critical" }, { "author": "CNVD", "id": "CNVD-2022-15163", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202202-1300", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-15163" }, { "db": "JVNDB", "id": "JVNDB-2022-004961" }, { "db": "CNNVD", "id": "CNNVD-202202-1300" }, { "db": "NVD", "id": "CVE-2021-46263" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer overflow in the wifiTime module. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data. Tenda AC series router AC11 Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC11 is a router from the Chinese company Tenda", "sources": [ { "db": "NVD", "id": "CVE-2021-46263" }, { "db": "JVNDB", "id": "JVNDB-2022-004961" }, { "db": "CNVD", "id": "CNVD-2022-15163" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-46263", "trust": 3.8 }, { "db": "JVNDB", "id": "JVNDB-2022-004961", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2022-15163", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202202-1300", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-15163" }, { "db": "JVNDB", "id": "JVNDB-2022-004961" }, { "db": "CNNVD", "id": "CNNVD-202202-1300" }, { "db": "NVD", "id": "CVE-2021-46263" } ] }, "id": "VAR-202202-1055", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2022-15163" } ], "trust": 1.6 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-15163" } ] }, "last_update_date": "2024-11-23T23:00:57.922000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top\u00a0Page", "trust": 0.8, "url": "https://www.tendacn.com/default.html" }, { "title": "Patch for Tenda AC Series Router Buffer Overflow Vulnerability (CNVD-2022-15163)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/322296" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-15163" }, { "db": "JVNDB", "id": "JVNDB-2022-004961" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-004961" }, { "db": "NVD", "id": "CVE-2021-46263" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://github.com/ainevsia/cve-request/tree/main/tenda/11" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-46263" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-15163" }, { "db": "JVNDB", "id": "JVNDB-2022-004961" }, { "db": "CNNVD", "id": "CNNVD-202202-1300" }, { "db": "NVD", "id": "CVE-2021-46263" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2022-15163" }, { "db": "JVNDB", "id": "JVNDB-2022-004961" }, { "db": "CNNVD", "id": "CNNVD-202202-1300" }, { "db": "NVD", "id": "CVE-2021-46263" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-02-27T00:00:00", "db": "CNVD", "id": "CNVD-2022-15163" }, { "date": "2023-05-12T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-004961" }, { "date": "2022-02-15T00:00:00", "db": "CNNVD", "id": "CNNVD-202202-1300" }, { "date": "2022-02-15T20:15:07.587000", "db": "NVD", "id": "CVE-2021-46263" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-02-27T00:00:00", "db": "CNVD", "id": "CNVD-2022-15163" }, { "date": "2023-05-12T03:35:00", "db": "JVNDB", "id": "JVNDB-2022-004961" }, { "date": "2022-03-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202202-1300" }, { "date": "2024-11-21T06:33:50.040000", "db": "NVD", "id": "CVE-2021-46263" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202202-1300" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda\u00a0AC\u00a0 series router \u00a0AC11\u00a0 Out-of-bounds write vulnerability in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-004961" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202202-1300" } ], "trust": 0.6 } }
var-202202-1238
Vulnerability from variot
Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer overflow in the PPPoE module. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data. Tenda AC series router AC11 Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC11 is a router from the Chinese company Tenda
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202202-1238", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac11", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "02.03.01.104_cn" }, { "model": "ac11", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac11 firmware 02.03.01.104_cn" }, { "model": "ac11", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac series router ac11 v02.03.01.104 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-15166" }, { "db": "JVNDB", "id": "JVNDB-2022-004962" }, { "db": "NVD", "id": "CVE-2021-46262" } ] }, "cve": "CVE-2021-46262", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2021-46262", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CNVD-2022-15166", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2021-46262", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-46262", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-46262", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2021-46262", "trust": 0.8, "value": "Critical" }, { "author": "CNVD", "id": "CNVD-2022-15166", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202202-1299", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-15166" }, { "db": "JVNDB", "id": "JVNDB-2022-004962" }, { "db": "CNNVD", "id": "CNNVD-202202-1299" }, { "db": "NVD", "id": "CVE-2021-46262" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer overflow in the PPPoE module. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data. Tenda AC series router AC11 Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC11 is a router from the Chinese company Tenda", "sources": [ { "db": "NVD", "id": "CVE-2021-46262" }, { "db": "JVNDB", "id": "JVNDB-2022-004962" }, { "db": "CNVD", "id": "CNVD-2022-15166" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-46262", "trust": 3.8 }, { "db": "JVNDB", "id": "JVNDB-2022-004962", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2022-15166", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202202-1299", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-15166" }, { "db": "JVNDB", "id": "JVNDB-2022-004962" }, { "db": "CNNVD", "id": "CNNVD-202202-1299" }, { "db": "NVD", "id": "CVE-2021-46262" } ] }, "id": "VAR-202202-1238", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2022-15166" } ], "trust": 1.6 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-15166" } ] }, "last_update_date": "2024-11-23T21:58:30.878000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top\u00a0Page", "trust": 0.8, "url": "https://www.tendacn.com/default.html" }, { "title": "Patch for Tenda AC Series Router Buffer Overflow Vulnerability (CNVD-2022-15166)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/322281" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-15166" }, { "db": "JVNDB", "id": "JVNDB-2022-004962" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-004962" }, { "db": "NVD", "id": "CVE-2021-46262" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://github.com/ainevsia/cve-request/tree/main/tenda/7" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-46262" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-15166" }, { "db": "JVNDB", "id": "JVNDB-2022-004962" }, { "db": "CNNVD", "id": "CNNVD-202202-1299" }, { "db": "NVD", "id": "CVE-2021-46262" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2022-15166" }, { "db": "JVNDB", "id": "JVNDB-2022-004962" }, { "db": "CNNVD", "id": "CNNVD-202202-1299" }, { "db": "NVD", "id": "CVE-2021-46262" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-02-27T00:00:00", "db": "CNVD", "id": "CNVD-2022-15166" }, { "date": "2023-05-12T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-004962" }, { "date": "2022-02-15T00:00:00", "db": "CNNVD", "id": "CNNVD-202202-1299" }, { "date": "2022-02-15T20:15:07.527000", "db": "NVD", "id": "CVE-2021-46262" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-02-27T00:00:00", "db": "CNVD", "id": "CNVD-2022-15166" }, { "date": "2023-05-12T03:35:00", "db": "JVNDB", "id": "JVNDB-2022-004962" }, { "date": "2022-03-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202202-1299" }, { "date": "2024-11-21T06:33:49.880000", "db": "NVD", "id": "CVE-2021-46262" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202202-1299" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda\u00a0AC\u00a0 series router \u00a0AC11\u00a0 Out-of-bounds write vulnerability in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-004962" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202202-1299" } ], "trust": 0.6 } }
var-202105-1126
Vulnerability from variot
An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /goform/setmac allows attackers to execute arbitrary code on the system via a crafted post request. Tenda AC11 The device contains an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Tenda AC11 is an AC1200 dual-band Gigabit WiFi router
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202105-1126", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac11", "scope": "lte", "trust": 1.0, "vendor": "tenda", "version": "02.03.01.104_cn" }, { "model": "ac11", "scope": "lte", "trust": 0.8, "vendor": "tenda", "version": "ac11 firmware 02.03.01.104_cn until" }, { "model": "ac11", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac11 \u003c=02.03.01.104 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-33998" }, { "db": "JVNDB", "id": "JVNDB-2021-006370" }, { "db": "NVD", "id": "CVE-2021-31755" } ] }, "cve": "CVE-2021-31755", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CVE-2021-31755", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2021-33998", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2021-31755", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-31755", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-31755", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2021-31755", "trust": 0.8, "value": "Critical" }, { "author": "CNVD", "id": "CNVD-2021-33998", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202105-380", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-31755", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-33998" }, { "db": "VULMON", "id": "CVE-2021-31755" }, { "db": "JVNDB", "id": "JVNDB-2021-006370" }, { "db": "CNNVD", "id": "CNNVD-202105-380" }, { "db": "NVD", "id": "CVE-2021-31755" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /goform/setmac allows attackers to execute arbitrary code on the system via a crafted post request. Tenda AC11 The device contains an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Tenda AC11 is an AC1200 dual-band Gigabit WiFi router", "sources": [ { "db": "NVD", "id": "CVE-2021-31755" }, { "db": "JVNDB", "id": "JVNDB-2021-006370" }, { "db": "CNVD", "id": "CNVD-2021-33998" }, { "db": "VULMON", "id": "CVE-2021-31755" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-31755", "trust": 3.9 }, { "db": "JVNDB", "id": "JVNDB-2021-006370", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-33998", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202105-380", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-31755", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-33998" }, { "db": "VULMON", "id": "CVE-2021-31755" }, { "db": "JVNDB", "id": "JVNDB-2021-006370" }, { "db": "CNNVD", "id": "CNNVD-202105-380" }, { "db": "NVD", "id": "CVE-2021-31755" } ] }, "id": "VAR-202105-1126", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-33998" } ], "trust": 1.6 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-33998" } ] }, "last_update_date": "2024-08-14T15:38:02.649000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top\u00a0Page", "trust": 0.8, "url": "https://www.tendacn.com/en/default.html" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-006370" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-006370" }, { "db": "NVD", "id": "CVE-2021-31755" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.1, "url": "https://github.com/yu3h0/iot_cve/tree/main/tenda/cve_3" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-31755" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/787.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-33998" }, { "db": "VULMON", "id": "CVE-2021-31755" }, { "db": "JVNDB", "id": "JVNDB-2021-006370" }, { "db": "CNNVD", "id": "CNNVD-202105-380" }, { "db": "NVD", "id": "CVE-2021-31755" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-33998" }, { "db": "VULMON", "id": "CVE-2021-31755" }, { "db": "JVNDB", "id": "JVNDB-2021-006370" }, { "db": "CNNVD", "id": "CNNVD-202105-380" }, { "db": "NVD", "id": "CVE-2021-31755" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-05-11T00:00:00", "db": "CNVD", "id": "CNVD-2021-33998" }, { "date": "2021-05-07T00:00:00", "db": "VULMON", "id": "CVE-2021-31755" }, { "date": "2022-01-06T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-006370" }, { "date": "2021-05-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202105-380" }, { "date": "2021-05-07T23:15:07.047000", "db": "NVD", "id": "CVE-2021-31755" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-05-11T00:00:00", "db": "CNVD", "id": "CNVD-2021-33998" }, { "date": "2021-05-10T00:00:00", "db": "VULMON", "id": "CVE-2021-31755" }, { "date": "2022-01-06T00:57:00", "db": "JVNDB", "id": "JVNDB-2021-006370" }, { "date": "2021-05-11T00:00:00", "db": "CNNVD", "id": "CNNVD-202105-380" }, { "date": "2021-05-10T14:57:33.257000", "db": "NVD", "id": "CVE-2021-31755" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202105-380" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda\u00a0AC11\u00a0 Out-of-bounds write vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-006370" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202105-380" } ], "trust": 0.6 } }
var-202202-1734
Vulnerability from variot
Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer overflow in the wanBasicCfg module. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data. Tenda AC series router AC11 Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC11 is a router from the Chinese company Tenda
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202202-1734", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac11", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "02.03.01.104_cn" }, { "model": "ac11", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac11 firmware 02.03.01.104_cn" }, { "model": "ac11", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac series router ac11 v02.03.01.104 cn", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-15165" }, { "db": "JVNDB", "id": "JVNDB-2022-004959" }, { "db": "NVD", "id": "CVE-2021-46265" } ] }, "cve": "CVE-2021-46265", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2021-46265", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CNVD-2022-15165", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2021-46265", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-46265", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-46265", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2021-46265", "trust": 0.8, "value": "Critical" }, { "author": "CNVD", "id": "CNVD-2022-15165", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202202-1301", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-15165" }, { "db": "JVNDB", "id": "JVNDB-2022-004959" }, { "db": "CNNVD", "id": "CNNVD-202202-1301" }, { "db": "NVD", "id": "CVE-2021-46265" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer overflow in the wanBasicCfg module. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data. Tenda AC series router AC11 Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC11 is a router from the Chinese company Tenda", "sources": [ { "db": "NVD", "id": "CVE-2021-46265" }, { "db": "JVNDB", "id": "JVNDB-2022-004959" }, { "db": "CNVD", "id": "CNVD-2022-15165" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-46265", "trust": 3.8 }, { "db": "JVNDB", "id": "JVNDB-2022-004959", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2022-15165", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202202-1301", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-15165" }, { "db": "JVNDB", "id": "JVNDB-2022-004959" }, { "db": "CNNVD", "id": "CNNVD-202202-1301" }, { "db": "NVD", "id": "CVE-2021-46265" } ] }, "id": "VAR-202202-1734", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2022-15165" } ], "trust": 1.6 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-15165" } ] }, "last_update_date": "2024-11-23T22:24:58.268000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top\u00a0Page", "trust": 0.8, "url": "https://www.tendacn.com/default.html" }, { "title": "Patch for Tenda AC Series Router Buffer Overflow Vulnerability (CNVD-2022-15165)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/322286" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-15165" }, { "db": "JVNDB", "id": "JVNDB-2022-004959" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-004959" }, { "db": "NVD", "id": "CVE-2021-46265" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://github.com/ainevsia/cve-request/tree/main/tenda/13" }, { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-46265" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-15165" }, { "db": "JVNDB", "id": "JVNDB-2022-004959" }, { "db": "CNNVD", "id": "CNNVD-202202-1301" }, { "db": "NVD", "id": "CVE-2021-46265" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2022-15165" }, { "db": "JVNDB", "id": "JVNDB-2022-004959" }, { "db": "CNNVD", "id": "CNNVD-202202-1301" }, { "db": "NVD", "id": "CVE-2021-46265" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-02-27T00:00:00", "db": "CNVD", "id": "CNVD-2022-15165" }, { "date": "2023-05-12T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-004959" }, { "date": "2022-02-15T00:00:00", "db": "CNNVD", "id": "CNNVD-202202-1301" }, { "date": "2022-02-15T20:15:07.707000", "db": "NVD", "id": "CVE-2021-46265" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-02-27T00:00:00", "db": "CNVD", "id": "CNVD-2022-15165" }, { "date": "2023-05-12T03:35:00", "db": "JVNDB", "id": "JVNDB-2022-004959" }, { "date": "2022-03-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202202-1301" }, { "date": "2024-11-21T06:33:50.343000", "db": "NVD", "id": "CVE-2021-46265" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202202-1301" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda\u00a0AC\u00a0 series router \u00a0AC11\u00a0 Out-of-bounds write vulnerability in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-004959" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202202-1301" } ], "trust": 0.6 } }
cve-2021-31758
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_2 | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T23:03:33.774Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_2" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2021-04-24T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /goform/setportList allows attackers to execute arbitrary code on the system via a crafted post request." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-05-07T22:01:32", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_2" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-31758", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /goform/setportList allows attackers to execute arbitrary code on the system via a crafted post request." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_2", "refsource": "MISC", "url": "https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_2" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-31758", "datePublished": "2021-05-07T22:01:32", "dateReserved": "2021-04-23T00:00:00", "dateUpdated": "2024-08-03T23:03:33.774Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-46264
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/9 | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T05:02:11.428Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/9" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer overflow in the onlineList module. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-02-15T19:08:29", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/9" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-46264", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer overflow in the onlineList module. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/9", "refsource": "MISC", "url": "https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/9" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-46264", "datePublished": "2022-02-15T19:08:29", "dateReserved": "2022-01-10T00:00:00", "dateUpdated": "2024-08-04T05:02:11.428Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-31755
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_3 | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T23:03:33.780Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_3" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2021-31755", "options": [ { "Exploitation": "active" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-04T19:44:13.561933Z", "version": "2.0.3" }, "type": "ssvc" } }, { "other": { "content": { "dateAdded": "2021-11-03", "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?search_api_fulltext=CVE-2021-31755" }, "type": "kev" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-04T19:45:10.408Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2021-04-24T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /goform/setmac allows attackers to execute arbitrary code on the system via a crafted post request." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-05-07T22:01:44.000Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_3" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-31755", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /goform/setmac allows attackers to execute arbitrary code on the system via a crafted post request." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_3", "refsource": "MISC", "url": "https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_3" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-31755", "datePublished": "2021-05-07T22:01:44.000Z", "dateReserved": "2021-04-23T00:00:00.000Z", "dateUpdated": "2025-02-04T19:45:10.408Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-46265
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/13 | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T05:02:10.381Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/13" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer overflow in the wanBasicCfg module. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-02-15T19:08:31", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/13" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-46265", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer overflow in the wanBasicCfg module. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/13", "refsource": "MISC", "url": "https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/13" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-46265", "datePublished": "2022-02-15T19:08:31", "dateReserved": "2022-01-10T00:00:00", "dateUpdated": "2024-08-04T05:02:10.381Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-46321
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/15 | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T05:02:11.312Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/15" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer overflow in the wifiBasicCfg module. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-02-15T19:08:32", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/15" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-46321", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer overflow in the wifiBasicCfg module. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/15", "refsource": "MISC", "url": "https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/15" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-46321", "datePublished": "2022-02-15T19:08:32", "dateReserved": "2022-01-18T00:00:00", "dateUpdated": "2024-08-04T05:02:11.312Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-31757
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_4 | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T23:03:33.751Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_4" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2021-04-24T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /goform/setVLAN allows attackers to execute arbitrary code on the system via a crafted post request." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-05-07T22:02:02", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_4" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-31757", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /goform/setVLAN allows attackers to execute arbitrary code on the system via a crafted post request." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_4", "refsource": "MISC", "url": "https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_4" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-31757", "datePublished": "2021-05-07T22:02:02", "dateReserved": "2021-04-23T00:00:00", "dateUpdated": "2024-08-03T23:03:33.751Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-46262
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/7 | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T05:02:11.322Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/7" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer overflow in the PPPoE module. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-02-15T19:08:28", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/7" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-46262", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer overflow in the PPPoE module. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/7", "refsource": "MISC", "url": "https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/7" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-46262", "datePublished": "2022-02-15T19:08:28", "dateReserved": "2022-01-10T00:00:00", "dateUpdated": "2024-08-04T05:02:11.322Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-46263
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/11 | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T05:02:11.415Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/11" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer overflow in the wifiTime module. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-02-15T19:08:29", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/11" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-46263", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer overflow in the wifiTime module. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/11", "refsource": "MISC", "url": "https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/11" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-46263", "datePublished": "2022-02-15T19:08:29", "dateReserved": "2022-01-10T00:00:00", "dateUpdated": "2024-08-04T05:02:11.415Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-31756
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_1 | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T23:03:33.698Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_1" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2021-04-24T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /gofrom/setwanType allows attackers to execute arbitrary code on the system via a crafted post request. This occurs when input vector controlled by malicious attack get copied to the stack variable." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-05-07T22:01:18", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_1" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-31756", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /gofrom/setwanType allows attackers to execute arbitrary code on the system via a crafted post request. This occurs when input vector controlled by malicious attack get copied to the stack variable." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_1", "refsource": "MISC", "url": "https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_1" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-31756", "datePublished": "2021-05-07T22:01:18", "dateReserved": "2021-04-23T00:00:00", "dateUpdated": "2024-08-03T23:03:33.698Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_2 | Exploit, Issue Tracking, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_2 | Exploit, Issue Tracking, Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac11_firmware | * | |
tenda | ac11 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac11_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "08B4F9BE-9D0D-4297-A0EE-2B8D4853DD0E", "versionEndIncluding": "02.03.01.104_cn", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac11:-:*:*:*:*:*:*:*", "matchCriteriaId": "8850E87F-3B1D-4D24-8F22-B358B27EE582", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /goform/setportList allows attackers to execute arbitrary code on the system via a crafted post request." }, { "lang": "es", "value": "Se detect\u00f3 un problema en los dispositivos Tenda AC11 con versiones de firmware hasta 02.03.01.104_CN.\u0026#xa0;Una vulnerabilidad de desbordamiento del b\u00fafer de la pila en el archivo /goform/setmac, permite a atacantes ejecutar c\u00f3digo arbitrario en el sistema por medio de una petici\u00f3n post dise\u00f1ada" } ], "id": "CVE-2021-31758", "lastModified": "2024-11-21T06:06:11.370", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-05-07T23:15:07.137", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Issue Tracking", "Third Party Advisory" ], "url": "https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_2" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Issue Tracking", "Third Party Advisory" ], "url": "https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_2" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_4 | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_4 | Exploit, Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac11_firmware | * | |
tenda | ac11 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac11_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "08B4F9BE-9D0D-4297-A0EE-2B8D4853DD0E", "versionEndIncluding": "02.03.01.104_cn", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac11:-:*:*:*:*:*:*:*", "matchCriteriaId": "8850E87F-3B1D-4D24-8F22-B358B27EE582", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /goform/setVLAN allows attackers to execute arbitrary code on the system via a crafted post request." }, { "lang": "es", "value": "Se detect\u00f3 un problema en los dispositivos Tenda AC11 con firmware hasta la versi\u00f3n 02.03.01.104_CN. Una vulnerabilidad de desbordamiento del b\u00fafer de la pila en /goform/setVLAN permite a los atacantes ejecutar c\u00f3digo arbitrario en el sistema a trav\u00e9s de una solicitud de correo manipulada" } ], "id": "CVE-2021-31757", "lastModified": "2024-11-21T06:06:11.220", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-05-07T23:15:07.107", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_4" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_4" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/7 | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/7 | Exploit, Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac11_firmware | 02.03.01.104_cn | |
tenda | ac11 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac11_firmware:02.03.01.104_cn:*:*:*:*:*:*:*", "matchCriteriaId": "F3B27213-BB07-4FC1-B1BD-27920A125681", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac11:-:*:*:*:*:*:*:*", "matchCriteriaId": "8850E87F-3B1D-4D24-8F22-B358B27EE582", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer overflow in the PPPoE module. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data." }, { "lang": "es", "value": "Se ha detectado que el router Tenda AC Series versi\u00f3n AC11_V02.03.01.104_CN, contiene un desbordamiento del b\u00fafer de la pila en el m\u00f3dulo PPPoE. Esta vulnerabilidad permite a atacantes causar una denegaci\u00f3n de servicio (DoS) por medio de datos de desbordamiento dise\u00f1ados" } ], "id": "CVE-2021-46262", "lastModified": "2024-11-21T06:33:49.880", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-02-15T20:15:07.527", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/7" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/7" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/13 | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/13 | Exploit, Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac11_firmware | 02.03.01.104_cn | |
tenda | ac11 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac11_firmware:02.03.01.104_cn:*:*:*:*:*:*:*", "matchCriteriaId": "F3B27213-BB07-4FC1-B1BD-27920A125681", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac11:-:*:*:*:*:*:*:*", "matchCriteriaId": "8850E87F-3B1D-4D24-8F22-B358B27EE582", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer overflow in the wanBasicCfg module. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data." }, { "lang": "es", "value": "Se ha detectado que el router Tenda AC Series versi\u00f3n AC11_V02.03.01.104_CN, contiene un desbordamiento del b\u00fafer de la pila en el m\u00f3dulo wanBasicCfg. Esta vulnerabilidad permite a atacantes causar una denegaci\u00f3n de servicio (DoS) por medio de datos de desbordamiento dise\u00f1ados" } ], "id": "CVE-2021-46265", "lastModified": "2024-11-21T06:33:50.343", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-02-15T20:15:07.707", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/13" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/13" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/9 | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/9 | Exploit, Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac11_firmware | 02.03.01.104_cn | |
tenda | ac11 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac11_firmware:02.03.01.104_cn:*:*:*:*:*:*:*", "matchCriteriaId": "F3B27213-BB07-4FC1-B1BD-27920A125681", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac11:-:*:*:*:*:*:*:*", "matchCriteriaId": "8850E87F-3B1D-4D24-8F22-B358B27EE582", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer overflow in the onlineList module. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data." }, { "lang": "es", "value": "Se ha detectado que el router Tenda AC Series versi\u00f3n AC11_V02.03.01.104_CN, contiene un desbordamiento del b\u00fafer de la pila en el m\u00f3dulo onlineList. Esta vulnerabilidad permite a atacantes causar una denegaci\u00f3n de servicio (DoS) por medio de datos de desbordamiento dise\u00f1ados" } ], "id": "CVE-2021-46264", "lastModified": "2024-11-21T06:33:50.190", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-02-15T20:15:07.650", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/9" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/9" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_3 | Exploit, Issue Tracking, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_3 | Exploit, Issue Tracking, Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac11_firmware | * | |
tenda | ac11 | - |
{ "cisaActionDue": "2021-11-17", "cisaExploitAdd": "2021-11-03", "cisaRequiredAction": "Apply updates per vendor instructions.", "cisaVulnerabilityName": "Tenda AC11 Router Stack Buffer Overflow Vulnerability", "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac11_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "08B4F9BE-9D0D-4297-A0EE-2B8D4853DD0E", "versionEndIncluding": "02.03.01.104_cn", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac11:-:*:*:*:*:*:*:*", "matchCriteriaId": "8850E87F-3B1D-4D24-8F22-B358B27EE582", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /goform/setmac allows attackers to execute arbitrary code on the system via a crafted post request." }, { "lang": "es", "value": "Se detect\u00f3 un problema en los dispositivos Tenda AC11 con firmware hasta 02.03.01.104_CN. Una vulnerabilidad de desbordamiento del b\u00fafer de la pila en /goform/setmac permite a los atacantes ejecutar c\u00f3digo arbitrario en el sistema a trav\u00e9s de una solicitud de correo manipulada" } ], "id": "CVE-2021-31755", "lastModified": "2025-02-04T20:15:42.933", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2021-05-07T23:15:07.047", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Issue Tracking", "Third Party Advisory" ], "url": "https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_3" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Issue Tracking", "Third Party Advisory" ], "url": "https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_3" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/11 | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/11 | Exploit, Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac11_firmware | 02.03.01.104_cn | |
tenda | ac11 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac11_firmware:02.03.01.104_cn:*:*:*:*:*:*:*", "matchCriteriaId": "F3B27213-BB07-4FC1-B1BD-27920A125681", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac11:-:*:*:*:*:*:*:*", "matchCriteriaId": "8850E87F-3B1D-4D24-8F22-B358B27EE582", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer overflow in the wifiTime module. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data." }, { "lang": "es", "value": "Se ha detectado que el router Tenda AC Series versi\u00f3n AC11_V02.03.01.104_CN, contiene un desbordamiento del b\u00fafer de la pila en el m\u00f3dulo wifiTime. Esta vulnerabilidad permite a atacantes causar una denegaci\u00f3n de servicio (DoS) por medio de datos de desbordamiento dise\u00f1ados" } ], "id": "CVE-2021-46263", "lastModified": "2024-11-21T06:33:50.040", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-02-15T20:15:07.587", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/11" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/11" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/15 | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/15 | Exploit, Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac11_firmware | 02.03.01.104_cn | |
tenda | ac11 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac11_firmware:02.03.01.104_cn:*:*:*:*:*:*:*", "matchCriteriaId": "F3B27213-BB07-4FC1-B1BD-27920A125681", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac11:-:*:*:*:*:*:*:*", "matchCriteriaId": "8850E87F-3B1D-4D24-8F22-B358B27EE582", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer overflow in the wifiBasicCfg module. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data." }, { "lang": "es", "value": "Se ha detectado que el router Tenda AC Series versi\u00f3n AC11_V02.03.01.104_CN, contiene un desbordamiento del b\u00fafer de la pila en el m\u00f3dulo wifiBasicCfg. Esta vulnerabilidad permite a atacantes causar una denegaci\u00f3n de servicio (DoS) por medio de datos desbordados dise\u00f1ados" } ], "id": "CVE-2021-46321", "lastModified": "2024-11-21T06:33:52.760", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-02-15T20:15:07.770", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/15" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/15" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_1 | Exploit, Issue Tracking, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_1 | Exploit, Issue Tracking, Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac11_firmware | * | |
tenda | ac11 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac11_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "08B4F9BE-9D0D-4297-A0EE-2B8D4853DD0E", "versionEndIncluding": "02.03.01.104_cn", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac11:-:*:*:*:*:*:*:*", "matchCriteriaId": "8850E87F-3B1D-4D24-8F22-B358B27EE582", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /gofrom/setwanType allows attackers to execute arbitrary code on the system via a crafted post request. This occurs when input vector controlled by malicious attack get copied to the stack variable." }, { "lang": "es", "value": "Se detect\u00f3 un problema en los dispositivos Tenda AC11 con firmware hasta la versi\u00f3n 02.03.01.104_CN. Una vulnerabilidad de desbordamiento del b\u00fafer de la pila en /gofrom/setwanType permite a los atacantes ejecutar c\u00f3digo arbitrario en el sistema a trav\u00e9s de una solicitud de entrada manipulada. Esto ocurre cuando el vector de entrada controlado por el ataque malicioso se copia en la variable de pila" } ], "id": "CVE-2021-31756", "lastModified": "2024-11-21T06:06:11.083", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-05-07T23:15:07.077", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Issue Tracking", "Third Party Advisory" ], "url": "https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_1" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Issue Tracking", "Third Party Advisory" ], "url": "https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_1" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }