Vulnerabilites related to Lenovo Group Ltd. - System x IMM2
cve-2018-9068
Vulnerability from cvelistv5
Published
2018-07-26 19:00
Modified
2024-09-17 03:38
Severity ?
Summary
The IMM2 First Failure Data Capture function collects management module logs and diagnostic information when a hardware error is detected. This information is made available for download through an SFTP server hosted on the IMM2 management network interface. In versions earlier than 4.90 for Lenovo System x and earlier than 6.80 for IBM System x, the credentials to access the SFTP server are hard-coded and described in the IMM2 documentation, allowing an attacker with management network access to obtain the collected FFDC data. After applying the update, the IMM2 will create random SFTP credentials for use with OneCLI.
References
Impacted products
Vendor Product Version
Lenovo Group Ltd. System x IMM2 Version: firmware versions earlier than 4.90
Create a notification for this product.
   IBM Corporation System x IMM2 Version: firmware versions earlier than 6.80
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T07:17:50.331Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://support.lenovo.com/us/en/solutions/LEN-20227"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "System x IMM2",
          "vendor": "Lenovo Group Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "firmware versions earlier than 4.90"
            }
          ]
        },
        {
          "product": "System x IMM2",
          "vendor": "IBM Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "firmware versions earlier than 6.80"
            }
          ]
        }
      ],
      "datePublic": "2018-07-26T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "The IMM2 First Failure Data Capture function collects management module logs and diagnostic information when a hardware error is detected. This information is made available for download through an SFTP server hosted on the IMM2 management network interface. In versions earlier than 4.90 for Lenovo System x and earlier than 6.80 for IBM System x, the credentials to access the SFTP server are hard-coded and described in the IMM2 documentation, allowing an attacker with management network access to obtain the collected FFDC data. After applying the update, the IMM2 will create random SFTP credentials for use with OneCLI."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Information disclosure",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-07-26T18:57:01",
        "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "shortName": "lenovo"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://support.lenovo.com/us/en/solutions/LEN-20227"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@lenovo.com",
          "DATE_PUBLIC": "2018-07-26T00:00:00",
          "ID": "CVE-2018-9068",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "System x IMM2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "firmware versions earlier than 4.90"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Lenovo Group Ltd."
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "System x IMM2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "firmware versions earlier than 6.80"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "IBM Corporation"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The IMM2 First Failure Data Capture function collects management module logs and diagnostic information when a hardware error is detected. This information is made available for download through an SFTP server hosted on the IMM2 management network interface. In versions earlier than 4.90 for Lenovo System x and earlier than 6.80 for IBM System x, the credentials to access the SFTP server are hard-coded and described in the IMM2 documentation, allowing an attacker with management network access to obtain the collected FFDC data. After applying the update, the IMM2 will create random SFTP credentials for use with OneCLI."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Information disclosure"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.lenovo.com/us/en/solutions/LEN-20227",
              "refsource": "CONFIRM",
              "url": "https://support.lenovo.com/us/en/solutions/LEN-20227"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
    "assignerShortName": "lenovo",
    "cveId": "CVE-2018-9068",
    "datePublished": "2018-07-26T19:00:00Z",
    "dateReserved": "2018-03-27T00:00:00",
    "dateUpdated": "2024-09-17T03:38:52.294Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}