Vulnerabilites related to WAGO - Series PFC 200 (750-82xx/xxx-xxx)
cve-2020-12522
Vulnerability from cvelistv5
Published
2020-12-17 22:40
Modified
2024-09-16 18:14
Severity ?
EPSS score ?
Summary
The reported vulnerability allows an attacker who has network access to the device to execute code with specially crafted packets in WAGO Series PFC 100 (750-81xx/xxx-xxx), Series PFC 200 (750-82xx/xxx-xxx), Series Wago Touch Panel 600 Standard Line (762-4xxx), Series Wago Touch Panel 600 Advanced Line (762-5xxx), Series Wago Touch Panel 600 Marine Line (762-6xxx) with firmware versions <=FW10.
References
▼ | URL | Tags |
---|---|---|
https://cert.vde.com/en-us/advisories/vde-2020-045 | x_refsource_CONFIRM |
Impacted products
Vendor | Product | Version | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | WAGO | Series PFC 100 (750-81xx/xxx-xxx) |
Version: FW1 < |
|||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T11:56:52.067Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-045" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Series PFC 100 (750-81xx/xxx-xxx)", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "FW10", "status": "affected", "version": "FW1", "versionType": "custom" } ] }, { "product": "Series PFC 200 (750-82xx/xxx-xxx)", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "FW10", "status": "affected", "version": "FW1", "versionType": "custom" } ] }, { "product": "Series Wago Touch Panel 600 Standard Line (762-4xxx)", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "FW10", "status": "affected", "version": "FW1", "versionType": "custom" } ] }, { "product": "Series Wago Touch Panel 600 Advanced Line (762-5xxx)", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "FW10", "status": "affected", "version": "FW1", "versionType": "custom" } ] }, { "product": "Series Wago Touch Panel 600 Marine Line (762-6xxx)", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "FW10", "status": "affected", "version": "FW1", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "This vulnerability was originally found by Florian Seidel of WAGO and was rediscovered by Uri Katz of Claroty. We thank CERT@VDE for the management of this coordinated disclosure." } ], "datePublic": "2020-12-17T00:00:00", "descriptions": [ { "lang": "en", "value": "The reported vulnerability allows an attacker who has network access to the device to execute code with specially crafted packets in WAGO Series PFC 100 (750-81xx/xxx-xxx), Series PFC 200 (750-82xx/xxx-xxx), Series Wago Touch Panel 600 Standard Line (762-4xxx), Series Wago Touch Panel 600 Advanced Line (762-5xxx), Series Wago Touch Panel 600 Marine Line (762-6xxx) with firmware versions \u003c=FW10." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 10, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 OS Command Injection", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-12-17T22:40:48", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-045" } ], "solutions": [ { "lang": "en", "value": "The I/O-Check service protocol is only needed during installation and commissioning, not during normal operations. It is highly recommended to disable the I/O-Check service after commissioning. This is the easiest and securest way to protect your device from the listed vulnerabilities.\n\nRegardless to the action described above, the vulnerability has been fixed in FW11, released in December 2017." } ], "source": { "advisory": "VDE-2020-045", "defect": [ "VDE-2020-045" ], "discovery": "INTERNAL" }, "title": "Command Injection Vulnerability in I/O-Check Service of WAGO PFC100, PFC200 and Touch Panel 600 Series with firmware versions \u003c=FW10", "workarounds": [ { "lang": "en", "value": "Disable I/O-Check service\nRestrict network access to the device.\nDo not directly connect the device to the internet." } ], "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "AKA": "", "ASSIGNER": "info@cert.vde.com", "DATE_PUBLIC": "2020-12-17T09:00:00.000Z", "ID": "CVE-2020-12522", "STATE": "PUBLIC", "TITLE": "Command Injection Vulnerability in I/O-Check Service of WAGO PFC100, PFC200 and Touch Panel 600 Series with firmware versions \u003c=FW10" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Series PFC 100 (750-81xx/xxx-xxx)", "version": { "version_data": [ { "platform": "", "version_affected": "\u003c=", "version_name": "FW1", "version_value": "FW10" } ] } }, { "product_name": "Series PFC 200 (750-82xx/xxx-xxx)", "version": { "version_data": [ { "platform": "", "version_affected": "\u003c=", "version_name": "FW1", "version_value": "FW10" } ] } }, { "product_name": "Series Wago Touch Panel 600 Standard Line (762-4xxx)", "version": { "version_data": [ { "platform": "", "version_affected": "\u003c=", "version_name": "FW1", "version_value": "FW10" } ] } }, { "product_name": "Series Wago Touch Panel 600 Advanced Line (762-5xxx)", "version": { "version_data": [ { "platform": "", "version_affected": "\u003c=", "version_name": "FW1", "version_value": "FW10" } ] } }, { "product_name": "Series Wago Touch Panel 600 Marine Line (762-6xxx)", "version": { "version_data": [ { "platform": "", "version_affected": "\u003c=", "version_name": "FW1", "version_value": "FW10" } ] } } ] }, "vendor_name": "WAGO" } ] } }, "configuration": [], "credit": [ { "lang": "eng", "value": "This vulnerability was originally found by Florian Seidel of WAGO and was rediscovered by Uri Katz of Claroty. We thank CERT@VDE for the management of this coordinated disclosure." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The reported vulnerability allows an attacker who has network access to the device to execute code with specially crafted packets in WAGO Series PFC 100 (750-81xx/xxx-xxx), Series PFC 200 (750-82xx/xxx-xxx), Series Wago Touch Panel 600 Standard Line (762-4xxx), Series Wago Touch Panel 600 Advanced Line (762-5xxx), Series Wago Touch Panel 600 Marine Line (762-6xxx) with firmware versions \u003c=FW10." } ] }, "exploit": [], "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 10, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-78 OS Command Injection" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert.vde.com/en-us/advisories/vde-2020-045", "refsource": "CONFIRM", "url": "https://cert.vde.com/en-us/advisories/vde-2020-045" } ] }, "solution": [ { "lang": "en", "value": "The I/O-Check service protocol is only needed during installation and commissioning, not during normal operations. It is highly recommended to disable the I/O-Check service after commissioning. This is the easiest and securest way to protect your device from the listed vulnerabilities.\n\nRegardless to the action described above, the vulnerability has been fixed in FW11, released in December 2017." } ], "source": { "advisory": "VDE-2020-045", "defect": [ "VDE-2020-045" ], "discovery": "INTERNAL" }, "work_around": [ { "lang": "en", "value": "Disable I/O-Check service\nRestrict network access to the device.\nDo not directly connect the device to the internet." } ] } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2020-12522", "datePublished": "2020-12-17T22:40:48.065139Z", "dateReserved": "2020-04-30T00:00:00", "dateUpdated": "2024-09-16T18:14:32.808Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }