Vulnerabilites related to Secomea GateManager all versions prior to 9.2c - Secomea GateManager all versions prior to 9.2c
cve-2020-14500
Vulnerability from cvelistv5
Published
2020-08-25 13:12
Modified
2024-09-17 03:34
Severity ?
Summary
Secomea GateManager all versions prior to 9.2c, An attacker can send a negative value and overwrite arbitrary data.
References
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T12:46:34.672Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-210-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Secomea GateManager all versions prior to 9.2c",
          "vendor": "Secomea GateManager all versions prior to 9.2c",
          "versions": [
            {
              "lessThan": "9.2c",
              "status": "affected",
              "version": "all",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2020-07-28T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Secomea GateManager all versions prior to 9.2c, An attacker can send a negative value and overwrite arbitrary data."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-158",
              "description": "IMPROPER NEUTRALIZATION OF NULL BYTE OR NUL CHARACTER CWE-158",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-08-25T13:12:30",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-210-01"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "IMPROPER NEUTRALIZATION OF NULL BYTE OR NUL CHARACTER CWE-158",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2020-07-28T00:00:00.000Z",
          "ID": "CVE-2020-14500",
          "STATE": "PUBLIC",
          "TITLE": "IMPROPER NEUTRALIZATION OF NULL BYTE OR NUL CHARACTER CWE-158"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Secomea GateManager all versions prior to 9.2c",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "all",
                            "version_value": "9.2c"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Secomea GateManager all versions prior to 9.2c"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Secomea GateManager all versions prior to 9.2c, An attacker can send a negative value and overwrite arbitrary data."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "IMPROPER NEUTRALIZATION OF NULL BYTE OR NUL CHARACTER CWE-158"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-210-01",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-210-01"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-14500",
    "datePublished": "2020-08-25T13:12:30.705759Z",
    "dateReserved": "2020-06-19T00:00:00",
    "dateUpdated": "2024-09-17T03:34:07.630Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}