Vulnerabilites related to BlackBerry - QNX Software Development Platform (QNX SDP)
cve-2017-3892
Vulnerability from cvelistv5
Published
2017-11-14 21:00
Modified
2024-09-17 02:06
Severity ?
Summary
In BlackBerry QNX Software Development Platform (SDP) 6.6.0, an information disclosure vulnerability in the default configuration of the QNX SDP could allow an attacker to gain information relating to memory layout that could be used in a blended attack by executing commands targeting procfs resources.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:39:41.193Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "QNX Software Development Platform (QNX SDP)",
          "vendor": "BlackBerry",
          "versions": [
            {
              "status": "affected",
              "version": "6.6.0"
            }
          ]
        }
      ],
      "datePublic": "2017-11-14T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In BlackBerry QNX Software Development Platform (SDP) 6.6.0, an information disclosure vulnerability in the default configuration of the QNX SDP could allow an attacker to gain information relating to memory layout that could be used in a blended attack by executing commands targeting procfs resources."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Information disclosure",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-11-14T20:57:01",
        "orgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
        "shortName": "blackberry"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@blackberry.com",
          "DATE_PUBLIC": "2017-11-14T00:00:00",
          "ID": "CVE-2017-3892",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "QNX Software Development Platform (QNX SDP)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "6.6.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "BlackBerry"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In BlackBerry QNX Software Development Platform (SDP) 6.6.0, an information disclosure vulnerability in the default configuration of the QNX SDP could allow an attacker to gain information relating to memory layout that could be used in a blended attack by executing commands targeting procfs resources."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Information disclosure"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674",
              "refsource": "CONFIRM",
              "url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
    "assignerShortName": "blackberry",
    "cveId": "CVE-2017-3892",
    "datePublished": "2017-11-14T21:00:00Z",
    "dateReserved": "2016-12-21T00:00:00",
    "dateUpdated": "2024-09-17T02:06:07.298Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2017-9371
Vulnerability from cvelistv5
Published
2017-11-14 21:00
Modified
2024-09-16 20:42
Severity ?
Summary
In BlackBerry QNX Software Development Platform (SDP) 6.6.0 and 6.5.0 SP1 and earlier, a loss of integrity vulnerability in the default configuration of the QNX SDP could allow an attacker being able to reduce the entropy of the PRNG, making other blended attacks more practical by gaining control over environmental factors that influence seed generation.
Impacted products
Vendor Product Version
BlackBerry QNX Software Development Platform (QNX SDP) Version: 6.6.0
Version: 6.5.0 SP1 and earlier
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T17:02:44.372Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://support.blackberry.com/kb/articleDetail?language=en_US\u0026articleNumber=000046674"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "QNX Software Development Platform (QNX SDP)",
          "vendor": "BlackBerry",
          "versions": [
            {
              "status": "affected",
              "version": "6.6.0"
            },
            {
              "status": "affected",
              "version": "6.5.0 SP1 and earlier"
            }
          ]
        }
      ],
      "datePublic": "2017-11-14T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In BlackBerry QNX Software Development Platform (SDP) 6.6.0 and 6.5.0 SP1 and earlier, a loss of integrity vulnerability in the default configuration of the QNX SDP could allow an attacker being able to reduce the entropy of the PRNG, making other blended attacks more practical by gaining control over environmental factors that influence seed generation."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Loss of integrity vulnerability",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-11-14T20:57:01",
        "orgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
        "shortName": "blackberry"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://support.blackberry.com/kb/articleDetail?language=en_US\u0026articleNumber=000046674"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@blackberry.com",
          "DATE_PUBLIC": "2017-11-14T00:00:00",
          "ID": "CVE-2017-9371",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "QNX Software Development Platform (QNX SDP)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "6.6.0"
                          },
                          {
                            "version_value": "6.5.0 SP1 and earlier"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "BlackBerry"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In BlackBerry QNX Software Development Platform (SDP) 6.6.0 and 6.5.0 SP1 and earlier, a loss of integrity vulnerability in the default configuration of the QNX SDP could allow an attacker being able to reduce the entropy of the PRNG, making other blended attacks more practical by gaining control over environmental factors that influence seed generation."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Loss of integrity vulnerability"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://support.blackberry.com/kb/articleDetail?language=en_US\u0026articleNumber=000046674",
              "refsource": "CONFIRM",
              "url": "http://support.blackberry.com/kb/articleDetail?language=en_US\u0026articleNumber=000046674"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
    "assignerShortName": "blackberry",
    "cveId": "CVE-2017-9371",
    "datePublished": "2017-11-14T21:00:00Z",
    "dateReserved": "2017-06-02T00:00:00",
    "dateUpdated": "2024-09-16T20:42:20.508Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2017-9369
Vulnerability from cvelistv5
Published
2017-11-14 21:00
Modified
2024-09-16 17:08
Severity ?
Summary
In BlackBerry QNX Software Development Platform (SDP) 6.6.0 and 6.5.0 SP1 and earlier, an information disclosure vulnerability in the default configuration of the QNX SDP could allow an attacker to gain information relating to memory layout of higher privileged processes by manipulating environment variables that influence the loader.
Impacted products
Vendor Product Version
BlackBerry QNX Software Development Platform (QNX SDP) Version: 6.6.0
Version: 6.5.0 SP1 and earlier
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T17:02:44.381Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "QNX Software Development Platform (QNX SDP)",
          "vendor": "BlackBerry",
          "versions": [
            {
              "status": "affected",
              "version": "6.6.0"
            },
            {
              "status": "affected",
              "version": "6.5.0 SP1 and earlier"
            }
          ]
        }
      ],
      "datePublic": "2017-11-14T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In BlackBerry QNX Software Development Platform (SDP) 6.6.0 and 6.5.0 SP1 and earlier, an information disclosure vulnerability in the default configuration of the QNX SDP could allow an attacker to gain information relating to memory layout of higher privileged processes by manipulating environment variables that influence the loader."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Information disclosure across privilege barriers.",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-11-14T20:57:01",
        "orgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
        "shortName": "blackberry"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@blackberry.com",
          "DATE_PUBLIC": "2017-11-14T00:00:00",
          "ID": "CVE-2017-9369",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "QNX Software Development Platform (QNX SDP)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "6.6.0"
                          },
                          {
                            "version_value": "6.5.0 SP1 and earlier"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "BlackBerry"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In BlackBerry QNX Software Development Platform (SDP) 6.6.0 and 6.5.0 SP1 and earlier, an information disclosure vulnerability in the default configuration of the QNX SDP could allow an attacker to gain information relating to memory layout of higher privileged processes by manipulating environment variables that influence the loader."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Information disclosure across privilege barriers."
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674",
              "refsource": "CONFIRM",
              "url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
    "assignerShortName": "blackberry",
    "cveId": "CVE-2017-9369",
    "datePublished": "2017-11-14T21:00:00Z",
    "dateReserved": "2017-06-02T00:00:00",
    "dateUpdated": "2024-09-16T17:08:03.615Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2017-3891
Vulnerability from cvelistv5
Published
2017-11-14 21:00
Modified
2024-09-16 23:20
Severity ?
Summary
In BlackBerry QNX Software Development Platform (SDP) 6.6.0, an elevation of privilege vulnerability in the default configuration of the QNX SDP with QNet enabled on networks comprising two or more QNet nodes could allow an attacker to access local and remote files or take ownership of files on other QNX nodes regardless of permissions by executing commands targeting arbitrary nodes from a secondary QNX 6.6.0 QNet node.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:39:41.298Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.midnightbluelabs.com/blog/2017/12/8/elevation-of-privilege-vulnerability-in-qnx-qnet"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "QNX Software Development Platform (QNX SDP)",
          "vendor": "BlackBerry",
          "versions": [
            {
              "status": "affected",
              "version": "6.6.0"
            }
          ]
        }
      ],
      "datePublic": "2017-11-14T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In BlackBerry QNX Software Development Platform (SDP) 6.6.0, an elevation of privilege vulnerability in the default configuration of the QNX SDP with QNet enabled on networks comprising two or more QNet nodes could allow an attacker to access local and remote files or take ownership of files on other QNX nodes regardless of permissions by executing commands targeting arbitrary nodes from a secondary QNX 6.6.0 QNet node."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Elevation of privilege",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-12-11T23:57:01",
        "orgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
        "shortName": "blackberry"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.midnightbluelabs.com/blog/2017/12/8/elevation-of-privilege-vulnerability-in-qnx-qnet"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@blackberry.com",
          "DATE_PUBLIC": "2017-11-14T00:00:00",
          "ID": "CVE-2017-3891",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "QNX Software Development Platform (QNX SDP)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "6.6.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "BlackBerry"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In BlackBerry QNX Software Development Platform (SDP) 6.6.0, an elevation of privilege vulnerability in the default configuration of the QNX SDP with QNet enabled on networks comprising two or more QNet nodes could allow an attacker to access local and remote files or take ownership of files on other QNX nodes regardless of permissions by executing commands targeting arbitrary nodes from a secondary QNX 6.6.0 QNet node."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Elevation of privilege"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674",
              "refsource": "CONFIRM",
              "url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
            },
            {
              "name": "https://www.midnightbluelabs.com/blog/2017/12/8/elevation-of-privilege-vulnerability-in-qnx-qnet",
              "refsource": "MISC",
              "url": "https://www.midnightbluelabs.com/blog/2017/12/8/elevation-of-privilege-vulnerability-in-qnx-qnet"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
    "assignerShortName": "blackberry",
    "cveId": "CVE-2017-3891",
    "datePublished": "2017-11-14T21:00:00Z",
    "dateReserved": "2016-12-21T00:00:00",
    "dateUpdated": "2024-09-16T23:20:52.137Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2017-3893
Vulnerability from cvelistv5
Published
2017-11-14 21:00
Modified
2024-09-16 18:13
Severity ?
Summary
In BlackBerry QNX Software Development Platform (SDP) 6.6.0, the default configuration of the QNX SDP system did not in all circumstances prevent attackers from modifying the GOT or PLT tables with buffer overflow attacks.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:39:41.483Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "QNX Software Development Platform (QNX SDP)",
          "vendor": "BlackBerry",
          "versions": [
            {
              "status": "affected",
              "version": "6.6.0"
            }
          ]
        }
      ],
      "datePublic": "2017-11-14T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In BlackBerry QNX Software Development Platform (SDP) 6.6.0, the default configuration of the QNX SDP system did not in all circumstances prevent attackers from modifying the GOT or PLT tables with buffer overflow attacks."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Flawed vulnerability mitigation",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-11-14T20:57:01",
        "orgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
        "shortName": "blackberry"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@blackberry.com",
          "DATE_PUBLIC": "2017-11-14T00:00:00",
          "ID": "CVE-2017-3893",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "QNX Software Development Platform (QNX SDP)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "6.6.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "BlackBerry"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In BlackBerry QNX Software Development Platform (SDP) 6.6.0, the default configuration of the QNX SDP system did not in all circumstances prevent attackers from modifying the GOT or PLT tables with buffer overflow attacks."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Flawed vulnerability mitigation"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674",
              "refsource": "CONFIRM",
              "url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
    "assignerShortName": "blackberry",
    "cveId": "CVE-2017-3893",
    "datePublished": "2017-11-14T21:00:00Z",
    "dateReserved": "2016-12-21T00:00:00",
    "dateUpdated": "2024-09-16T18:13:43.090Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}