Vulnerabilites related to Dell - PowerEdge BIOS Intel 16G
cve-2024-0162
Vulnerability from cvelistv5
Published
2024-03-13 16:18
Modified
2024-08-01 20:17
Severity ?
EPSS score ?
Summary
Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an Improper SMM communication buffer verification vulnerability. A local low privileged attacker could potentially exploit this vulnerability leading to out-of-bound read/writes to SMRAM.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Dell | PowerEdge BIOS Intel 16G |
Version: N/A ≤ Version: N/A ≤ Version: N/A ≤ Version: N/A ≤ Version: N/A ≤ Version: N/A ≤ Version: N/A ≤ Version: N/A ≤ |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T17:41:16.017Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://www.dell.com/support/kbdoc/en-us/000222812/dsa-2024-004-security-update-for-dell-poweredge-server-bios-for-an-improper-smm-communication-buffer-verification-vulnerability" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2024-0162", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-07-26T13:41:24.076852Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-01T20:17:13.932Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "PowerEdge BIOS Intel 16G", "vendor": "Dell", "versions": [ { "lessThan": " 2.0.0", "status": "affected", "version": "N/A", "versionType": "semver" }, { "lessThan": "1.7.6", "status": "affected", "version": "N/A", "versionType": "semver" }, { "lessThan": "1.7.2", "status": "affected", "version": "N/A", "versionType": "semver" }, { "lessThan": "1.2.3", "status": "affected", "version": "N/A", "versionType": "semver" }, { "lessThan": "1.13.2", "status": "affected", "version": "N/A", "versionType": "semver" }, { "lessThan": "1.9.1", "status": "affected", "version": "N/A", "versionType": "semver" }, { "lessThan": "1.14.1", "status": "affected", "version": "N/A", "versionType": "semver" }, { "lessThan": "2.14.1", "status": "affected", "version": "N/A", "versionType": "semver" } ] } ], "datePublic": "2024-03-12T06:30:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an Improper SMM communication buffer verification vulnerability. A local low privileged attacker could potentially exploit this vulnerability leading to out-of-bound read/writes to SMRAM." } ], "value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an Improper SMM communication buffer verification vulnerability. A local low privileged attacker could potentially exploit this vulnerability leading to out-of-bound read/writes to SMRAM." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:L", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-119", "description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-13T16:18:23.730Z", "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "shortName": "dell" }, "references": [ { "tags": [ "vendor-advisory" ], "url": "https://www.dell.com/support/kbdoc/en-us/000222812/dsa-2024-004-security-update-for-dell-poweredge-server-bios-for-an-improper-smm-communication-buffer-verification-vulnerability" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "assignerShortName": "dell", "cveId": "CVE-2024-0162", "datePublished": "2024-03-13T16:18:23.730Z", "dateReserved": "2023-12-14T05:30:40.938Z", "dateUpdated": "2024-08-01T20:17:13.932Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-0163
Vulnerability from cvelistv5
Published
2024-03-13 16:28
Modified
2024-08-12 13:54
Severity ?
EPSS score ?
Summary
Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain a TOCTOU race condition vulnerability. A local low privileged attacker could potentially exploit this vulnerability to gain access to otherwise unauthorized resources.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Dell | PowerEdge BIOS Intel 16G |
Version: N/A ≤ Version: N/A ≤ Version: N/A ≤ Version: N/A ≤ Version: N/A ≤ Version: N/A ≤ Version: N/A ≤ Version: N/A ≤ |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T17:41:16.098Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://www.dell.com/support/kbdoc/en-us/000222756/dsa-2024-003-security-update-for-dell-poweredge-server-bios-for-a-time-of-check-time-of-use-toctou-vulnerability" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2024-0163", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-08-12T13:54:34.641518Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-12T13:54:53.369Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "PowerEdge BIOS Intel 16G", "vendor": "Dell", "versions": [ { "lessThan": "2.0.0", "status": "affected", "version": "N/A", "versionType": "semver" }, { "lessThan": "1.7.6", "status": "affected", "version": "N/A", "versionType": "semver" }, { "lessThan": "1.7.2", "status": "affected", "version": "N/A", "versionType": "semver" }, { "lessThan": "1.2.3", "status": "affected", "version": "N/A", "versionType": "semver" }, { "lessThan": "1.13.2", "status": "affected", "version": "N/A", "versionType": "semver" }, { "lessThan": "1.9.1", "status": "affected", "version": "N/A", "versionType": "semver" }, { "lessThan": "1.14.1", "status": "affected", "version": "N/A", "versionType": "semver" }, { "lessThan": "2.14.1", "status": "affected", "version": "N/A", "versionType": "semver" } ] } ], "datePublic": "2024-03-12T06:30:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain a TOCTOU race condition vulnerability. A local low privileged attacker could potentially exploit this vulnerability to gain access to otherwise unauthorized resources." } ], "value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain a TOCTOU race condition vulnerability. A local low privileged attacker could potentially exploit this vulnerability to gain access to otherwise unauthorized resources." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:L", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-367", "description": "CWE-367: Time-of-check Time-of-use (TOCTOU) Race Condition", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-13T16:28:00.444Z", "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "shortName": "dell" }, "references": [ { "tags": [ "vendor-advisory" ], "url": "https://www.dell.com/support/kbdoc/en-us/000222756/dsa-2024-003-security-update-for-dell-poweredge-server-bios-for-a-time-of-check-time-of-use-toctou-vulnerability" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "assignerShortName": "dell", "cveId": "CVE-2024-0163", "datePublished": "2024-03-13T16:28:00.444Z", "dateReserved": "2023-12-14T05:30:42.511Z", "dateUpdated": "2024-08-12T13:54:53.369Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }