Vulnerabilites related to ICS-CERT - PR100088 Modbus gateway
cve-2019-6533
Vulnerability from cvelistv5
Published
2019-02-12 17:00
Modified
2024-09-16 17:18
Severity ?
Summary
Registers used to store Modbus values can be read and written from the web interface without authentication in the PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166).
References
Impacted products
Vendor Product Version
ICS-CERT PR100088 Modbus gateway Version: All versions prior to Release R02 (or Software Version 1.1.13166)
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:23:21.788Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-036-05"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "PR100088 Modbus gateway",
          "vendor": "ICS-CERT",
          "versions": [
            {
              "status": "affected",
              "version": "All versions prior to Release R02 (or Software Version 1.1.13166)"
            }
          ]
        }
      ],
      "datePublic": "2019-02-05T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Registers used to store Modbus values can be read and written from the web interface without authentication in the PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166)."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-02-12T16:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-036-05"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2019-02-05T00:00:00",
          "ID": "CVE-2019-6533",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "PR100088 Modbus gateway",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions prior to Release R02 (or Software Version 1.1.13166)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ICS-CERT"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Registers used to store Modbus values can be read and written from the web interface without authentication in the PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166)."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-036-05",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-036-05"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2019-6533",
    "datePublished": "2019-02-12T17:00:00Z",
    "dateReserved": "2019-01-22T00:00:00",
    "dateUpdated": "2024-09-16T17:18:38.780Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-6527
Vulnerability from cvelistv5
Published
2019-02-12 17:00
Modified
2024-09-17 02:32
Severity ?
Summary
PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166) may allow an attacker to be able to change the password for an admin user who is currently or previously logged in, provided the device has not been restarted.
References
Impacted products
Vendor Product Version
ICS-CERT PR100088 Modbus gateway Version: All versions prior to Release R02 (or Software Version 1.1.13166)
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:23:21.535Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-036-05"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "PR100088 Modbus gateway",
          "vendor": "ICS-CERT",
          "versions": [
            {
              "status": "affected",
              "version": "All versions prior to Release R02 (or Software Version 1.1.13166)"
            }
          ]
        }
      ],
      "datePublic": "2019-02-05T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166) may allow an attacker to be able to change the password for an admin user who is currently or previously logged in, provided the device has not been restarted."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "IMPROPER AUTHENTICATION CWE-287",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-02-12T16:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-036-05"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2019-02-05T00:00:00",
          "ID": "CVE-2019-6527",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "PR100088 Modbus gateway",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions prior to Release R02 (or Software Version 1.1.13166)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ICS-CERT"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166) may allow an attacker to be able to change the password for an admin user who is currently or previously logged in, provided the device has not been restarted."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "IMPROPER AUTHENTICATION CWE-287"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-036-05",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-036-05"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2019-6527",
    "datePublished": "2019-02-12T17:00:00Z",
    "dateReserved": "2019-01-22T00:00:00",
    "dateUpdated": "2024-09-17T02:32:35.184Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-6549
Vulnerability from cvelistv5
Published
2019-02-12 18:00
Modified
2024-09-16 22:30
Severity ?
Summary
An attacker could retrieve plain-text credentials stored in a XML file on PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166) through FTP.
References
Impacted products
Vendor Product Version
ICS-CERT PR100088 Modbus gateway Version: All versions prior to Release R02 (or Software Version 1.1.13166)
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:23:21.488Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-036-05"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "PR100088 Modbus gateway",
          "vendor": "ICS-CERT",
          "versions": [
            {
              "status": "affected",
              "version": "All versions prior to Release R02 (or Software Version 1.1.13166)"
            }
          ]
        }
      ],
      "datePublic": "2019-02-05T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An attacker could retrieve plain-text credentials stored in a XML file on PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166) through FTP."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CLEARTEXT STORAGE OF SENSITIVE INFORMATION CWE-312",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-02-12T17:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-036-05"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2019-02-05T00:00:00",
          "ID": "CVE-2019-6549",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "PR100088 Modbus gateway",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions prior to Release R02 (or Software Version 1.1.13166)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ICS-CERT"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An attacker could retrieve plain-text credentials stored in a XML file on PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166) through FTP."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CLEARTEXT STORAGE OF SENSITIVE INFORMATION CWE-312"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-036-05",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-036-05"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2019-6549",
    "datePublished": "2019-02-12T18:00:00Z",
    "dateReserved": "2019-01-22T00:00:00",
    "dateUpdated": "2024-09-16T22:30:41.714Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}